Effect of Inclination Angle on Temperature Characteristics of Water in- Glass Evacuated Tubes

Similar documents
Design and Performance Analysis of One Ended Evacuated Tubes at Different Air Flow Rates Nitin Panwar 1

An Experimental Study on Evacuated Tube Solar Collector for Heating of Air in India Avadhesh Yadav, V.K. Bajpai

IJSRD - International Journal for Scientific Research & Development Vol. 3, Issue 03, 2015 ISSN (online):

SOLAR WATER DISTILLATION BY USING WATER IN THE INNER GLASS EVACUATED TUBES

Experimental Studies on Aero Profile Thermosyphon Solar Water Heating System

Development of TRNSYS Models for Predicting the Performance of Water-in-Glass Evacuated Tube Solar Water Heaters in Australia

Experimental Investigation of a Hybrid Evacuated Tube Solar Collector

EFFECT OF DIVERSE STREAM PATTERNS ON THE PERFORMANCE OF SOLAR AIR HEATER

Evacuated U-Tube Solar Water Heating System- A Descriptive Study

Heat Transfer in Evacuated Tubular Solar Collectors

Performance of Water-in-Glass Evacuated Tube Solar Water Heaters

Falling Film Heat Exchangers for Solar Water Heaters

DESIGN, FABRICATION & PERFORMANCE ANALYSIS OF SOLAR AIR HEATER

Experimental Study and Analysis of Flat Plate Solar Water Heater with Different Flow Rates using of Circulating Pump

Solar collectors. Speaker

Performance analysis of solar water heater in NEH region of India

Assessment of Domestic Evacuated Tube. Direct Solar Water Heater

THERMAL PERFORMANCE ASSESSMENT OF GREENHOUSE SOLAR DRYER UNDER PASSIVE MODE

So far, we have covered the basic concepts of heat transfer and properties.

Experimental Analysis of Open, Simple and Modified Greenhouse Dryers for Drying Potato Flakes under Forced Convection

Experimental investigation of Hybrid Nanofluid on wickless heat pipe heat exchanger thermal performance

Chapter 3 DESIGN OF THE STUDY

Design, Construction and Testing of Simple Solar Maize Dryer

Thermal Performance Enhancement of Inclined Rib Roughness Solar Air Heater

Performance Analysis of Solar Air Heater Using Three Wire Mesh

Experimental & Analytical Investigation on Modified Solar Dryer with Recirculation of Air

PRODUCING COOLING FROM SOLAR ENERGY BY USING ADSORPTION CYCLE WITH ACTIVATED CARBON AND METHANOL PAIR

Computer Modelling and Simulation of a Smart Water Heater

Solar water heaters proposed for the British University in Egypt Bathrooms VS. Traditional electrical water

American International Journal of Research in Science, Technology, Engineering & Mathematics

Analysis of the performance profile of the NCERD thermosyphon solar water heater

Performance Analysis Of Double Inclination Ribbed Solar Air Heater Rectangular Duct By Liquid Crystal Thermography

International Forum on Energy, Environment Science and Materials (IFEESM 2015)

TRANSACTIONS ON ADVANCEMENTS IN SCIENCE AND TECHNOLOGY (TASTONLINE)

Performance Analysis for the Double- Pass Solar Air Collector with and Without Porous Media

INSTRUMENTATION AND EVALUATION OF COMMERCIAL AND HOMEMADE PASSIVE SOLAR PANELS

FABRICATION AND COMPARISON OF SOLAR WATER HEATER WITH AND WITHOUT SEMI CIRCULAR TROUGH

EFFECT OF WATER RADIATOR ON AIR HEATING SOLAR COLLECTOR EFFICIENCY

Performance Study of Solar Heat Pipe with Different Working Fluids and Fill Ratios

A Regional Research and Dissemination Programme. Phase III SOLAR BOX DRYER DESIGN, CONSTRUCTION AND OPERATION MANUAL

[Eswaran, 3(3): March, 2014] ISSN: Impact Factor: 1.852

EXPERIMENTAL PERFORMANCE ANALYSIS OF SOLAR AIR HEATER WITH THREE DIFFERENT MODIFICATIONS IN ABSORBER PLATE

Design and Optimization of Domestic Solar Dryer

Open and Closed Door Moisture Transport and Corresponding Energy Consumption in Household Refrigerator

Performance Assessment of Water Cooled Condenser Refrigeration System

To investigate the surface properties for increasing efficiency of solar water heater

EFFECTS OF VARIABLES ON NATURAL CONVECTIVE HEAT TRANSFER THROUGH V-CORRUGATED VERTICAL PLATES

DEVELOPMENT OF A PAR-BOILED RICE SOLAR DRYER

Experimental Investigation of Elliptical Tube Bank Cross Flow Heat Exchanger with Inline Arrangement & 45 Angle of Attack

Heat Transfer Enhancement using Herringbone wavy & Smooth Wavy fin Heat Exchanger for Hydraulic Oil Cooling

EXCELSIOR SINHGAD COLLEGE OF ENGINEERING, PUNE PAPER PRESENTATION

DESIGN AND CONSTRUCTION OF FORCED/NATURAL CONVECTION SOLAR VEGETABLE DRYER WITH HEAT STORAGE

TITLE: Improvement in Heat Transfer Rate and Dynamics of Shrouded Fanned Radiator System

Numerical Studies On The Performance Of Methanol Based Air To Air Heat Pipe Heat Exchanger

HEFAT th International Conference on Heat Transfer, Fluid Mechanics and Thermodynamics Sun City, South Africa Paper number:pp1

ACTIVE SOLAR DESIGN ALTERNATIVE ENEGRY SOURCES

Numerical investigation on the effect of channelled and unchannelled screens on smoke contamination in atriums upper balconies with open upstand

STUDY ON HYBRID SYSTEM OF SOLAR POWERED WATER HEATER AND ADSORPTION ICE MAKER

Design with nature: integrating green façades into sustainable buildings with reference to Abu Dhabi

COMPARATIVE ANALYSIS OF SINGLE AND DOUBLE EFFECT LiBr-WATER ABSORPTION SYSTEM

PERFORMANCE ANALYSIS OF A CONVENTIONAL AIR HEATER

Performance Enhancement of Mini Refrigerator with Phase Change Materials

APPLICATION OF MINI HEAT PIPES FOR THERMAL MANAGEMENT OF OPTO-ELECTRONIC INSTRUMENTS

Ultra Low Cost Solar Water Heater. Concept Generation and Selection Document

Experimental Comparison of Natural Convection Heat Transfer from a Blackened V-Fin Array

Performance analysis of overlapped solar air heater using CFD

Experimental Performance of Solar Collector cum Regenerator for Coupling with a Liquid Desiccant Cooling System

Compression of Fins pipe and simple Heat pipe Using CFD

ZONE MODEL VERIFICATION BY ELECTRIC HEATER

SCIENCE & TECHNOLOGY

Analysis of Evaporative Cooler and Tube in Tube Heat Exchanger in Intercooling of Gas Turbine

Experimental Study of Alternatives to Sand in Zeer Pot Refrigeration Technique

MINIMISING THE RISK OF WATER HAMMER AND OTHER PROBLEMS AT THE BEGINNING OF STAGNATION OF SOLAR THERMAL PLANTS- A THEORETICAL APPROACH

An Experimental Study of a Simple Vapour Compression Refrigeration System with Varying Parameters

DESIGN, ANALYSIS AND FABRICATION OF THERMOELECTRIC COOLING AND HEATING SYSTEM FOR WATER DISPENSER

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Air Conditioning System with Modified Condenser Ducts and Evaporative Cooling

Experimental Analysis of a Stirling Refrigerator Employing Jet-Impingement Heat Exchanger and Nanofluids

Performance Analysis of Li-Br Water Refrigeration System with Double Coil Anti-Swirl Shell and Coil Heat Exchangers

Design and Experimental Studies on Modified Solar Dryer

EFFECTIVE UTILIZATION OF SOLAR ENERGY IN AIR DRYER

RADIATION BLOCKAGE EFFECTS BY WATER CURTAIN

Performance Study of Triple Concentric Pipe Heat Exchanger

Raman et al., International Journal of Advanced Engineering Technology E-ISSN

Effect of Relative Humidity on Oven Temperature of Locally Design Solar Carbinet Dryer

Performance Analysis of a Thin Tube Water Heater for Egerton University Using Comsol

INDOOR CLIMATE IN HEATING CONDITION OF A LARGE GYMNASIUM WITH UNDER-FLOOR SUPPLY/RETURN SYSTEM

Performance of Shell and Tube Heat Exchanger under Varied Operating Conditions

Thermal Performance Of Low Cost Solar Bamboo Dryer

DEVELOPMENT OF FORCED CONVECTION SOLAR ONION DRYER

2. HEAT EXCHANGERS MESA

Theoretical model of circular solar collector for close water open air (CWOA) heated humidification and dehumidification

Energy Savings Potential of Passive Chilled Beam System as a Retrofit Option for Commercial Buildings in Different Climates

Smoldering Propagation Characteristics of Flexible Polyurethane Foam under Different Air Flow Rates

PASSIVE AND ACTIVE FIRE PROTECTION OF THE AIR HEATED SOLAR HOUSES

Enhancement of COP in Vapour Compression Refrigeration System

Fabrication & Performance Analysis of Solar Water Heater Using Porous Medium & Agitator

Performance Analysis of Heat Pipe using Different Screen Mesh Sizes Manikandan.K * 1, Senthilkumar.R 2,

A TRNSYS Simulation Case Study on Utilization of Heat Pump For both Heating and Cooling

Dynamic Simulation of Double Pipe Heat Exchanger using MATLAB simulink

Transcription:

International Conference on Ideas, Impact and Innovation in Mechanical Engineering (ICIIIME 217) ISSN: 2321-8169 Effect of Inclination Angle on Temperature Characteristics of Water in- Glass Evacuated Tubes Sheetal kanthekar 1, Priya Rai 2, A.V.Joshi 3 1 Sheetal Kanthekar, Department of Mechanical Engineering, SKNCOE, sheetalkanthekar44@gmail.com 2 Priya Rai,Department of Mechanical Engineering,SKNCOE, prai7228@gmail.com 3 Prof A.V.Joshi,Department of Mechanical Engineering,SKNCOE, avjoshi@sinhgad.edu. ABSTRACT The water-in-glass evacuated tube is an integral part of evacuated tube solar water heater. Solar water heaters with evacuated tube collectors perform better than that of flat plate collector. The usage of evacuated tube collectors is increasing day by day. For flat plate collectors it is essential that the inclination of the collectors should be based on the latitude of that place for better performance. This paper discusses the experimental study conducted on the evacuated tube collectors mounted at different angles of inclinations i.e 15, 3,45 degrees. The temperature characteristics obtained as a result of the experiment show that the performance varies with respect to angle of inclination. A salient feature of this study is the employment of twelve temperature sensors located inside of three tubes and three tanks. A data logger was used to collect data during the experiment on daily basis for seven hours. The data collected during the experiment shows the highest values of water temperatures for lesser inclination angles (15 degree) at earlier stages of the experiment. Keywords: Evacuated tube collector, Solar water heater, Collector tilt angle, Thermosyphon, Thermal Performanceetc. ----------------------------------------------------------------------------------------------------------------------------- 1.INTRODUCTION Solar energy, being abundant and widespread in its availability, makes it one of the most attractive sources of energies. Tapping this energy will not only help in bridging the gap between demand and supply of electricity but shall also save money in the long run. A Solar Water Heating System (SWHS) is a device that makes available the thermal energy of the incident solar radiation for use in various applications by heating the water [5]. The SWHS consists of solar thermal collectors, water tanks, interconnecting pipelines, and the water, which gets circulated in the system. Solar radiation incident on the collector heats up the tubes, thereby transferring the heat energy to water flowing through it. The performance of the SWHS largely depends on the collector s efficiency at capturing the incident solar radiation and transferring it to the water. With today s SWHS, water can be heated up to temperatures of 6 C to 8 C. Heated water is collected in a tank insulated to prevent heat loss. Circulation of water from the tank through the collectors and back to the tank continues automatically due to the thermosyphon principle [6]. The hot water generated finds many end-use applications in domestic, commercial, and industrial sectors. The evacuated tube solar collectors perform better in comparison to flat plate solar collectors, in particular for high temperature operations.one of the most significant developments is the use of double-glass evacuated tubular solar water heaters. The mechanism of this type of solar water heater is driven bynatural circulation of the fluid in the collector and the storage tank. It consists of all-glass vacuum tubes, inserted directly into a storage tank, with water in direct contact with the absorber surface. Morrison et al has mentioned that evacuated tube solar collectors perform better than flat plate collectors during high temperature operations [1]. Evacuated tube solar collector system is better option for domestic utilization because of its simplicity and low cost. 2. WORKING PRINCIPLE Solar Water Heater (ETC System) works on a simple principle Black body heat absorption principle. The principle says, black colour absorbs maximum heat, more than any other colour Solar water heating systems using vacuum tubes made of borosilicate glass with special coating to absorb the solar energy are called as Evacuated Tube Collector system (ETC Systems).Air between the gap of two glass tubes is evacuated. It results in high level of vacuum, which acts as the best insulation to minimize the heat loss from inner tube. The black coating on the inner tube absorbs the solar energy and transfers it to the water. The water on upper side of Vacuum Tube becomes hot and thus lighter, so it starts moving upwards in the tank. At the same time cold water, which is heavy, comes downward from the tank and is stored at the bottom. The phenomenon is called as natural Thermosyphon circulation, which occurs in every tube.thermosyphon Systems: In this type water flows through the system and when water gets 41

International Conference on Ideas, Impact and Innovation in Mechanical Engineering (ICIIIME 217) ISSN: 2321-8169 warm it rises as cooler water sinks. The collector is installed below the storage tank so that warm water will rise into the tank. These systems do not involve any pump and are more reliable. Fig-1: Working of Evacuated Tube Collector. 2.CONTRUCTIONAL FEATURES Main components of evacuated tube solar water heater:evacuated glass tubes and Barium Getter, Storage tank, Mounting Frame 2.1Evacuated Tubes The evacuated tube is made of borosilicate glass. The diameter of the tube is 47mm and the length is 15mm. Figure 2 shows the detail parts of the evacuated tube.the vacuum tubes consist of a double wall glass tube with a space in the centre which contains the heat pipe. The presence of the vacuum wall prevents any losses by conduction or convection - just like a thermos flask. Because of this, the system will work even in very low temperatures, unlike traditional flat plate collectors. In order to maintain the vacuum between the two glass layers, a barium getter is used. During manufacture this getter is exposed to high temperatures which cause the bottom of the evacuated tube to be coated with a pure layer of barium. This barium layer actively absorbs any CO, CO2, N2, O2, H2O and H2 out gassed from the tube during storage and operation, thus helping to maintaining the vacuum. The barium layer also provides a clear visual indicator of the vacuum status. The silver coloured barium layer will turn white if ever the vacuum is lost. Fig-2: Details of Evacuated Tube Collector. 2.2 Storage Tank It is a tank which stores the water and come from external water source like water tank. Outer cylindrical surface is covered by high tech insulating material (Rock Wool or mineral wool) in order to reduce the heat losses from the heated water exist inside the inner tank heated by the evacuated tube solar water heater. Rock wool is a man madefiber and has many excellent characters like non-combustible, non-toxic, low thermal conductivity, long service life and so on. Storage tank is placed at the top of frame and tubes. The top open end of the tubes is connected to the storage tank. The bottom end of tubes is placed in a holder provided at bottom of the frame. Figure 3 shows storage tank of 7 Litrecapacity. Fig-3: Storage Tank 42

International Conference on Ideas, Impact and Innovation in Mechanical Engineering (ICIIIME 217) ISSN: 2321-8169 2.3 Mounting Frame The whole system required a structure strong enough to hold up all the tubes at various angles at the same time.it is structure made of no. of metallic angle or plate, on which no. of units like storage tank tubes etc. are mounted.figure 6 shows a frame assembly for evacuated glass tube solar water heating system upto7 Litre Capacity. Fig-4:Mounting frame (creo model). 3.INSTRUMENTATION. Temperatures are to be measured in two places of the tube, viz., top and bottom. The type of thermocouple used in the experiment is a PT1 thermocouple with the maximum measuring capacity of 3 C. The thermocouple is calibrated with a series of minor experiments and checked for errors. Data logger used was Series DL-35W 16 channel. It supports various thermocouples including K-type, R-type and PT-1. We used PT-1 thermocouples for the experimentation. It is developed by Microcubs Systems Pvt. Ltd. Fig-5: Sensor PT(1) Fig-6: DAQ (Data logger). 4.EXPERIMENTAL DESCRIPTION The basic experimentation is to record the temperature readings of the water in the evacuated tubes at particular time intervals. The time intervals were chosen from a frequency of about once in every 15 minutes. Initially the experiment is conducted with tubes facing the south direction. Figure-5 gives the view of experimental set-up. The experiment is conducted on clear sun-shine day with global radiation of 82 W/m2. The solar radiation is measured with the help of pyranometer available in the solar radiation monitoring station. The readings are taken continuously for every one hour from 1. a.m. to 5. p.m. 4.1 Stagnation Test Fig-7: Experimental Setup. To find out the maximum temperature achieved inside the empty tube with air only, we conducted a test known as stagnation test. It gives temperature rise over the period of the day. If the temperature achieved is of around 2 C then tube is healthy and working properly. The observation table no. 1 gives the results of the stagnation test 1. With this check we assure manufacturing 43

TEMPERATURE TEMPERATURE 11::1 11:25: 11:4: 11:55: 12:1: 12:25: 12:4: 12:55: International Conference on Ideas, Impact and Innovation in Mechanical Engineering (ICIIIME 217) ISSN: 2321-8169 uniformity among all the tube. When these tubes are subjected to radiations they absorb same amount of radiations when kept at equal inclinations. The test setup was inclined at angle of 25 to the horizontal. The test was conducted for 2hours and results obtained were plotted against the time to verify the variation of the temperature along with radiation variation with respect to time. T1 stands for thermocouple reading of tube 1, T2 for thermocouple reading of tube 2 and T3 for thermocouple reading of tube 3. T4 is ambient air temperature during the test. Solar radiation intensity is also plotted into the graph to understand variation of the behaviour of the tubes. Fig-8: Stagnation test thermocouple location. Table-1:Stagnation test 1.Table-2:Stagnation test 2. Date Time T1 T2 T3 T4 18/2/217 11:15: 69.4 74.6 72.8 36.5 18/2/217 11:2: 94.5 11. 93.8 38.9 18/2/217 11::1 35.2 35.5 36. 35.5 18/2/217 11:25: 116.8 119.9 116.2 37.3 18/2/217 11:3: 136.7 135.6 134.5 36.8 18/2/217 11:35: 153.8 15.7 149.5 38.5 18/2/217 11:4: 168.2 163.7 161.8 37.4 18/2/217 11:45: 179.7 173.7 171. 38.6 18/2/217 11:5: 189.1 181.8 178.5 38.7 18/2/217 11:55: 197.1 188.2 184.2 38.6 18/2/217 12:: 22. 193.3 188.4 39.2 18/2/217 12:5: 25.7 196.2 191.3 39.1 Date Time T1 T2 T3 T4 18/2/217 14:25: 74.2 75.4 73.4 39.7 18/2/217 14:3: 95.7 9.8 91.4 4.4 18/2/217 14:35: 119.5 114.4 112.2 39.3 18/2/217 14:4: 14.1 134.4 13. 41. 18/2/217 14:45: 157.2 15.8 145.5 4.6 18/2/217 14:5: 171.1 164. 158.4 41.5 18/2/217 14:55: 182.3 174.5 168.2 39.6 18/2/217 15:: 189.4 182.5 176.3 39.6 18/2/217 15:5: 196.8 188.7 182.4 39.6 18/2/217 15:1: 22.6 193.5 186.7 39.6 18/2/217 15:15: 27.4 196.8 19.2 4.7 18/2/217 15:2: 21.8 199.3 192.5 4. 3 2 1 T1 T2 3 2 1 T1 T2 T3 T3 T4 T4 Fig-9: stagnation test(1). Fig-1: stagnation test(2). 4.2 System Heat loss Test All the assembly was preheated in the solar radiations for 4 to 5 hours for to get heated. Then evacuated tubes were covered to prevent heat gain from sun in the time of the day. Two hours temperature readings were taken. Temperature profiles were plotted for heating as well as cooling for finding out heat loss coefficient. If density of the liquid is ρ, Volume of the tank is V T, T f is final average temperature of the system. T i is final average temperature of the system. T is ambient air temperature. Time span is represented by (t2-t1) which in our case was two hours 44

TEMPERATURE International Conference on Ideas, Impact and Innovation in Mechanical Engineering (ICIIIME 217) ISSN: 2321-8169 Fig-11:System Heat Loss. U loss = ρv T C f (T f T i ) ln T i T T f T (t2 t1) (1). The formula used for calculations requires following properties to be known of the liquid. 1. Density of the liquid water. Assumed to be constant 1 kg/m3 2. Volume of the liquid bulk 3. Specific heat of water also constant for given temperature range 4. Initial and final temperatures of the bulk and ambient average temp. Various temperatures at instances are averaged throughout the setup. Ambient temperature was averaged over given span of time of conduction of the test. There are two ways to find out the heat loss coefficient viz. either we can apply transient analysis or can use standard formula for calculation of heat loss coefficient as proposed in standard procedure of ISO9459-2, 1995. Second way is to find useful heat gain rate during day from reference [1] et. al. Morrison and then subtracting it from irradiation to get heat lost during heating. First procedure seems to be easier from experimentation point of view hence first procedure was adopted in order to calculate heat loss coefficient. Table-3:Heat loss coefficient for 45 degree. Fig-12: Heat loss test graph 45 degree. Date Time T1 T2 T3 T4 22/3/217 17:5 62.5 61.1 58.4 53.5 8 22/3/217 17:1 61.7 6.8 58.4 53.4 6 22/3/217 17:15 61.4 6.5 58.4 53.4 4 22/3/217 17:2 6.8 6.2 58.4 53.4 2 22/3/217 17:25 6.4 6.1 57.6 53.3 22/3/217 17:3 6. 59.7 57.5 53.1 22/3/217 17:35 59.9 59.4 57.2 53.1 22/3/217 17:4 59.6 59.5 57.1 53. 22/3/217 17:45 59.3 6. 57. 52.7 22/3/217 17:5 59.1 59. 56.9 52.6 T1 T2 T3 T4 Table-4:Heat loss coefficient for 3 degree. Date Time T5 T6 T7 T8 22/3/217 17:5 63.2 62.2 62.8 57.3 22/3/217 17:1 62.5 61.8 62.7 57.5 22/3/217 17:15 62.3 61.6 62.6 57.6 22/3/217 17:2 62. 61.4 62.3 57.6 22/3/217 17:25 61.6 61.6 62.1 57.5 22/3/217 17:3 61.5 6.9 62.1 57.4 22/3/217 17:35 61.2 6.8 61.7 57.3 22/3/217 17:4 61. 6.4 61.6 57.3 22/3/217 17:45 6.7 6.2 61.4 57. 22/3/217 17:5 6.5 6. 61.3 56.9 Table-5:Heat loss coefficient for 15 degree. Fig-13: Heat loss test graph 3 degree. Fig-14: Heat loss test graph 15 degree. 45

1:55: AM 11:35: AM 12:15: PM 12:55: PM 1:35: PM 2:15: PM 2:55: PM 3:35: PM 4:15: PM 4:55: PM 5:35: PM TEMPERTAURE International Conference on Ideas, Impact and Innovation in Mechanical Engineering (ICIIIME 217) ISSN: 2321-8169 Date Time T9 T1 T11 T12 22/3/217 17:5 63.7 63.8 64.8 57.8 22/3/217 17:1 63.8 63.8 64.6 58.1 22/3/217 17:15 63.4 63.4 64.3 58.1 22/3/217 17:2 63.5 63.5 64.2 58.1 22/3/217 17:25 63. 63.1 64. 58. 22/3/217 17:3 62.8 63. 63.9 57.9 22/3/217 17:35 62.5 62.6 63.5 57.9 22/3/217 17:4 62.3 62.3 63.4 57.7 22/3/217 17:45 62.1 62.3 63.1 57.7 22/3/217 17:5 61.8 61.9 62.9 57.4 Test no Table-6: Heat Loss Coefficient Of System. Duration (hrs) T iavg ( c) T favg ( c) U loss (W/K) 1 1 56.69 54.41 2.263 2 1 6.37 58.52 1.286 3 1 61.6 59.78 1.186 5.RESULTS OF THE EXPERIMENT The temperature characteristics are plotted based on the observed readings from experimental set-up facing southdirection. DAY 1:On 29 Mar 217 Fig-15:Temperature characteristic at 45 degree. Fig-16:Temperature characteristic at 3 degree. 7 6 5 4 3 2 1 T9 T1 T11 T12 Fig-17:Temperature characteristic at 15degree. 46

1:: AM 1:4: AM 11:2: AM 12:: PM 12:4: PM 1:2: PM 2:: PM 2:4: PM 3:2: PM 4:: PM 4:4: PM TEMPERATURE International Conference on Ideas, Impact and Innovation in Mechanical Engineering (ICIIIME 217) ISSN: 2321-8169 DAY 2:On 1 st april 217 Fig-18:Temperature characteristic at 45 degree.fig-19:temperature characteristic at 3degree. 7 6 5 4 3 2 1 T9 T1 T11 T12 Fig-2:Temperaturecharacteristic at 15 degree. 6. CONCLUSION The temperature characteristics obtained as a result of the experiment show that the performance varies with respect to angle of inclination. The data collected during the experiment shows the highest values of water temperatures for lesser inclination angles (15 degree) at earlier stages of the experiment.the Heat loss coefficient is constant for all the three tubes, as shown from the graph (Fig no 12,13,14) hence all systems of tubes are uniform. For 15 degree system it is seen that temperature at the open end of the tube is maximum as compared to other loactions. Hence for smaller angles stagnation zone inside the tank is more dominant. On the other hand, for 45 degree system the initial variation shows higher departure of temperature for closed end of tube as compared to other locations. Hence stagnation zone is more dominant inside the tubes at higher angles. FUTURE SCOPE Further performance can be enhanced by using Owen illuinios tube inside the evacuated tube collector, which will eliminate stagnation zone fromthe system. Simulation of the Test Setup can be carried out to validate the results by using CFD software. ACKNOWLEDGEMENT We sincerely thank Dr Funde (Physics department SPPU, School of Energy studies) for supporting us in our project financially and morally and also to Regional Test Centre Pune for providing us solar radiation data. REFERENCES [1] G. D. Rai, Non-Conventional Energy Sources (Khanna Publishers, Delhi, 5th Edition, 211). [2] S. P. Sukhatme, J. K. Nayak, Solar Energy (The Tata MC Graw Hill Publication, Delhi, 3rd Edition, 21. 47

International Conference on Ideas, Impact and Innovation in Mechanical Engineering (ICIIIME 217) ISSN: 2321-8169 [3] G.L. Morrison, I.Budihardjo and M.Behnia, Water-In-Glass Evacuated Tube Solar Water Heaters, School of Mechanical and Manufacturing Engineering, University of New South Wales, Sydney, ISES 21 Solar World CongressK. Elissa, Title of paper if known, unpublished [4] Runsheng Tang, Yuqin Yang, Wenfeng Gao (211), Comparative studies on thermal performance of water-in-glass evacuated tube solar water heaters with different collector tilt-angles, Solar Energy, Vol.85, pp.1381-1385 [5] J. Dimas, M. Barrito, Effect of the tilt angle on thermal passive water in glass evacuated tube solar water heater, Applied Energy 155 (215) 684-659. [6] R. Tang, Y. Yang, W. Gao, Comparative studies on thermal performance of water-in-glass evacuated tube solar water heaters with different collector tilt angles, Solar Energy 85 (211) 1381-1389 48