Axial flow fan AXICO ANTI-STALL

Similar documents
AXICO ANTI-STALL CONTROLLABLE PITCH-IN-MOTION AND ADJUSTABLE PITCH-AT-REST VANEAXIAL FANS

Twin City Fan & Blower

JM Aerofoil Fans Bulletin JMA60-05

A. Codes and Standards that are Standard at the University:

Belt Driven Mixed Flow Fans

Evase Vaneaxial Fans 500mm to 1400mm Diameter Bulletin ECA 10-07

1 - Donkin Fans. Majax-2 Aerofoil Axial Flow Fans

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

Multistage Centrifugal Blowers

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

PFS Single stage axial fan The axial fan for modern boiler plants

MCF 500 CENTRIFUGAL FAN FOR AIR, FOR BIOGAS, LANDFILL AND NATURAL GAS

CombiBloc Close-coupled centrifugal pumps

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise Modular Climate Changer Full Spec. Prepared by: Phone Number: Prepared for:

Fans: Features and Analysis

Construction Standards Page Exclusively published and distributed by Architectural Computer Services, Inc. (ARCOM) for the AIA

Jet Fan Types AUC/ARC/AUR/ARR/AUO/ARO Installation and Maintenance

Multistage Centrifugal Blowers

CAP SERIES SEWAGE AND WASTE WATER PUMPS

High Plume Blowers Suggested Specification Section (Master Format 1996) Suggested Specification Section (Master Format 2004)

Centrifugal Fans, Non-Overloading, Backward Inclined

ACN SMOKE INSTALLATION AND MAINTENANCE

Multistage Centrifugal Blowers

CROSSFLOW FILM FILL PACKAGE COOLING TOWER. Number TYH SERIES LOW NOISE - ENERGY SAVINGS. Thermal-Cell Sdn Bhd ( M)

SIHI multi Modular multistage pumps

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

Installation and Maintenance Novax Smoke Exhaust Fan Type ACN Smoke

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Pumps Mixers Aeration Controls Services SCANPUMP SPLIT CASING PUMP Z22.

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

Selecting the Correct Fan

Goulds LP3400 Series Low Pulse Fan Pumps

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

SECTION XXXXX POSITIVE DISPLACEMENT BLOWER WITH SOUNDSEAL COMPACT ENCLOSURE

CRN A-F-G-E-HQQE 3x400D 50 HZ

SPECIFICATION DELETED SECTION CENTRIFUGAL HVAC FANS

What is a Closed circuit Cooling Tower (CCT)?

CombiBloc. Close-coupled centrifugal pumps

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. In-Line Pumps IIL / IVP / IVP-CC

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

FAN IMPELLERS & FAN CASINGS

1.1 This section applies to air handling units for HVAC Systems.

CPO N N O V A T I O N E F F I C I E N C Y Q U A L I T Y. ASME/ANSI B73.1 Chemical Process Pump. Springer Pumps, LLC

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

CR A-F-A-E-HQQE 3x400/ HZ

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION EXHAUST FANS

Rotodynamic Pumps INTRODUCTION:

Horizontal Split Case Pumps Type U

Specially Designed Waste Water & Sewage Pumps

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

AIR HANDLING UNITS Vibration Isolation Air Filtration Equipment Ductwork.

CR A-F-A-V-HQQV 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400D 50 HZ

CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

we make air move Double Inlet Centrifugal Fans (Forward Curved) FBD Series (Square Outlet Metric Size)

The SALA Series of. Vertical & horizontal ST Pumps. Tough, general purpose slurry pumps. ST pumps

Flow Control for Fire Protection

Transformer oil coolers BETA & CETA

Goulds Trash Hog. Self-Priming Solids Handling Pumps

UNIVERSITY OF ROCHESTER DESIGN STANDARDS NOVEMBER 1, 2013

NOVENCO BUILDING & INDUSTRY PRODUCTS. Products

Industrial Fans & Blowers

ANSI RAB QMS. Parag Energy Efficient Axial Flow FRP Fans

Hi-Pres. Self Contained A/C Unit HI-PRES MARINE & OFFSHORE

Vertical Ring-section Pump WKTB. Type Series Booklet

Montageanleitung RLO (Original) Mounting Instructions RLO (Translation of the original)

Installation of Two Main Fans at P.T. Freeport Indonesia's Underground Facilities

Featuring Ozone-safe HFC134a. Hitachi Centrifugal Chillers NEW. GXG-S Series GSG-S Series. Debut

Wall fans. High air performance and low energy consumption

English CNA-CNB. Centrifugal fans Installation and maintenance

Submersible A Series Wastewater Pumps AMX, AV and AK Hydraulic Ranges

WHY SULLAIR? For more information on the IHI-Sullair joint venture, please visit 2,000th IHI-Sullair centrifugal

SMHA Hatch High temperature fan HT-fan Installation and Maintenance

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

PUMP. Horizontal Multi-Stage Pump. Type MS SERIES DIMENSION. Model MSL MSH (2 pole motor drive) APPLICATIONS companion flange (SS) Foot valve

Commercial, Residential & Institutional Pumps, Tanks, & Accessories

CR20-07 A-F-A-E-HQQE 3x400/ HZ

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

BRT C/H Series PACKAGED AIR TO AIR UNITS COOLING / HEATING APPLICATIONS OUTDOOR INSTALLATION. Ver. 1.01

Energy Conservation with PARAG Energy Efficient Axial Flow FRP Fans

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Roots TM Blowers, Compressors & Controls

Instructions for the BASIC BCRW Fan, Sizes General

Tunnel Axial Flow Fan

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

University of Houston Master Construction Specifications Insert Project Name

UNIVERSITY SERVICES ANNEX James Madison University Harrisonburg, Virginia State Project Code: Architect s Project Number:

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

MCV - MCH - MCHZ Multistage pumps

Axial fans The right fan for every house

DUCTED SPLIT AIR CONDITIONERS GCUN-A/GDS-A SERIES

End-Suction Centrifugal Pump

Transcription:

Product data sheet: AXICO ANTI-STALL Axial flow fan AXICO ANTI-STALL Model FPAC and FPMC axial flow fans with controllable pitch blades. Air flow range: 3-110 m³/s (10.000 400.000 m³/h). Pressure rise: Up to 3000 Pa. The fans have completely stable flow and pressure characteristics which eliminates the risk of surging. The AXICO ANTI-STALL fans are used for comfort ventilation and for process ventilation and it meets the industrial requirements and can be adapted to meet specific requirements regarding materials, surface treatment, design, etc. The FPAC-1 axial-flow fan with a compact design guide vane diffuser Good operating economy Surge-free operation Good control economy - the fan blades are instantlyset to meet the flow requirements of the installation, without impairing the high efficiency Choice of suitable hub diameter and blade angle for optimum matching to the desired operating point Standard 4-pole or 6-pole foot-mounted motor or two-speed motor Low vibration level Low mass-moment of inertia - short starting time Short overall length Complete range of accessories Surface treated with 80-micron coat of alkyd paint Air flow Pressure rise Temp. range 3-110 m³/s 0-3000 Pa -15 to +40 C with regard to the insulation class of the motor 1

Applications Comfort ventilation Air handling units with AXICO ANTI-STALL fans are used principally in hospitals, offices, hotels, exhibition halls, sports arenas, shopping centres and similar buildings. All efforts are being made to achieve maximum compactness of conventional modular air handling units, in order to minimize building costs and space requirements. The AXICO ANTI-STALL CD range of fans has been developed specifically for such air handling units. CD stands for compact design. To make the fan as compact as possible, the guide vane section is integrated with a diffuser. The CD converts dynamic pressure into static without adding the length of a separate diffuser. Its short overall length makes the AXICO ANTI-STALL CD fan eminently suitable for all air handling units. Process ventilation What we normally recognize as process ventilation is the type of ventilation used in industrial plants, power stations, mines, paint shops clean rooms, offshore installations, garages and so on. Common criteria of all these plants are the strict demands as to factors such as reliability, resistance to corrosive environments (temperature, humidity), stable operating characteristics, spark-proof design and control accuracy. AXICO ANTI-STALL fans usually meet the industrial requirements and can be adapted to meet specific requirements regarding materials, surface treatment, spark-proof design, special motors, special designs, etc. For particulars of the special variants available, consult your nearest Howden representative. Design The fan is supplied as a complete unit consisting of a casing with stabilizing ring, guide vane assembly, impeller, blade pitch control mechanism, guard, motor to IEC standard, and motor stand. Anti-vibration mountings of high damping rubber type and a flexible duct of PVCcoated nylon fabric for connection to an outlet duct are supplied. In arrangement 6, the fan is also supplied with a flexible duct on the suction side. The unique stabilizing ring controls and stabilizes the turbulense occurring in a heavily throttled fan. An axial fan without this stabilizing ring would be forced to surge, which may eventually lead to material fatigue and operation disturbances. The fan is available in two versions: FPAC The blade angle is controlled by a diaphragm motor located in the hub of the impeller. The diaphragm motor is pneumatically actuated by means of a positioner. The FPAC offers accurate control of the blade angle, combined with fast response. The positioner operates with a pneumatic input signal or with an electric input signal as an option. FPMC The blade angle is controlled by an electromechanic actuator operating on a control lever. The actuator is an accessory which, when ordered simultaneously with the fan, is fitted to the outside of the casing. Materials and finish The main components of the impeller (hub, blades, etc.) are made of cast aluminium alloy. The control disc is made of cast iron. Other components of the fan, such as casing, stand, fasteners, shafts, etc., are mainly made of steel. The fan is painted with an 80-micron thick coat of blue alkyd paint. The fasteners are galvanized. Environmental class C1, ISO 9223 Fans to higher environmental class up to and including C4 are available to special order. Installation The fan is to be mounted on the supplied antivibration mountings which are secured to the floor. Instructions are submitted with the fan. Packaging The fan is delivered on a pallet, and is protected with plastic sheeting. Arrangements available Arrangement 1 The fan impeller is mounted directly on the motor shaft. This is a compact arrangement which is particularly suitable for air handling units. Arrangement 3 The impeller is beltdriven for high total pressure capacity. The motor is slidably mounted on a base frame, which makes the belt tension easy to adjust. The belt drive is provided with a galvanized steel guard. Arrangement 6 The impeller is mounted directly on the motor shaft. This arrangement is intended for connection to ducting on both sides. The FPAZ-21 inlet is used for open-suction installation. The fan can also be installed vertically. Vertical with upward direction of air flow Arrangement 7 Vertical with downward direction of air flow The impeller is mounted on an intermediate shaft connected to the motor by means of a highly elastic flexible coupling. The intermediate shaft is journalled in two bearing blocks. Grease nipples for periodic lubrication of the bearings are provided on the outside of the fan and are easily accessible. The motor can easily be replaced without the impeller and control components being disturbed. 2

Ordering key 3

FPAC impeller 4

FPMC impeller 5

For more information: Howden Axial Fans, Light Industry Nordic, Växjö, Sweden Tel: + 46 (0) 470 594 620 Fax: + 46 (0) 470 594 621 Email: Web: lightindustryfans@howden.com www.howden.com 6