Increase your flexibility.

Similar documents
SUBMITTAL AG015KSVAJH/AA Samsung DVM Heat Pump Chiller. Submitted to Reference Approval Construction Unit Designation Schedule #

Well rounded. 360 CASSETTE. A truly circular cassette. Enjoy even airflow from a beautifully sleek design that fits into any setting.

Submitted to Reference Approval Construction Unit Designation Schedule #

A single answer for multiple zones.

Cold Remedies. SamsungHVAC.com. Product Registration Required Conditions Apply

A single answer for multiple zones.

Submitted to Reference Approval Construction Unit Designation Schedule #

The ultimate fresh air solution.

Samsung 360 Cassette, Single Zone, Split System

Geniuses at work. Residential Mini Splits

Product Line Introduction. Karl Zhang Technical support engineer

LG VRF Systems. Air Conditioning Technologies

PAC (FLOOR STANDING) 2016 Samsung

VARIABLE REFRIGERANT FLOW (VRF) FULL LINE CATALOG

Submittal Data: LIVS09HP230V1B. Job Name Location Date. Submitted To. Cool Quiet Comfort & more 9,000 BTU/H (208/230V) Wall Mounted Heat Pump System

INVERTER SCROLL. LG Electronics Distributed by. Copyright 2017 LG Electronics. All rights reserved.

Submittal Data: VIR12HP230V1B. Job Name Location Date. Submitted To

Submittal Data: VIR09HP115V1B Job Name Location Date. Submitted To. Innovative Ductless solutions 9,000 BTU/H (115V) Wall Mounted Heat Pump System

INVERTER SCROLL INVERTER SCROLL INVERTER SCROLL. LG Electronics Distributed by

Submittal Data: VIR24HP230V1B. Job Name Location Date. Submitted To

Integrated VarIable refrigerant flow ahu/pau (r410a)

NFZP Variable Refrigerant Flow Guide Specification

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

DVM S Universal Communication Kit (UCK) Design Guide

Product Data. 38GJQ MULTI-ZONE DUCTLESS SYSTEM MATCHED WITH 40GRQ / 40GJB / 40GJC / 40GJD / 40GJF Indoor Units Sizes 18, 24, 30, 36, 42, 48 and 56

Samsung EHS, XL Range of Commercial Air to water heat pumps

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

SUBMITTAL DATA - OUTDOOR UNIT VEP075N432G VRF HEAT PUMP

CHILLER Technical Data Book DVM CHILLER for Europe (R410A, 50/60Hz, HP)

Simultaneous Chiller/Boiler Plants. Greg Drensky Vice President

NQ Series Portable Chillers

DC Inverter Smart VRF Products(R410A)

CXAV / CGAV. Trane Module Chiller. Industry top class efficiency and reliability

Variable Refrigeration Flow Systems Overview 10/11/2016

Hybrid VRF Next Generation 2-Pipe Heat Recovery Systems

Ductless Split Systems Concealed Duct Heat Pumps

18-2 AWG / 300V THHN Operating Range MCA 2.0A Cooling (Max) 118 F (48 C) MOCP/Breaker Size 15A (Min) 0 F (-18 C)

Performance Rating of Variable Refrigerant Flow (VRF) Multi-split Air-conditioning and Heat Pump Equipment

ENERGY-INTELLIGENT TECHNOLOGY HEATING AND COOLING SYSTEMS 5.16 LIGHT COMMERCIAL RESIDENTIAL AIR COOLED RENOVATION NEW CONSTRUCTION

Learn more about Samsung air conditioner at:

ELECTRICAL QUANTITY WEIGHT (LB)

Submittal Data: UMAT48HP230V1AF. Job Name Location Date. Submitted To

15A 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Power Input (Max) 1,500 W Dehumidification 1.7 pt/hr HSPF 10.5 COP 4.2 Compressor Type DC Inverter Driven 2-Stage Rotary Heating at 17 F FLA 8.

Efficiency Vermont The American Institute of Architects Continuing Education Systems (AIA/CES) AIA/CES AIA/CES

Technical Development Program. COMMERCIAL HVAC PACKAGED EQUIPMENT Split Systems PRESENTED BY: Ray Chow Sigler

Mini Chiller Air Cooled Axial Fan

Product Data INDUSTRY LEADING FEATURES / BENEFITS

mini-cassette W MULTI SPLIT R410A & VRF SERIES AUTO MODEL MDH13HLS MDH13HLS

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

High Heat COP. High/Low Stage

LENNOX MINI-VRF SYSTEMS. CONNECTING TECHNOLOGY WITH EXPERTISE.

Ductless Split Systems Wall-mounted, Single Zone Heat Pump

Project ID: 9217 Project name: Fuller Lake Arena Address: Fuller Lake, BC V0R 1K5 Project Type: Sports Complex / Civic Center

PERFORMANCE SERIES Single Zone & Multi-Zone Ductless Systems

50A KP 70A KP 90A KP 120A KP 150A KP 210A

... Air Conditioners & Heat Pumps Light Commercial ...

Emad Chen. Head of Qatar Office Midea Commercial Air Conditioner

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

DAIKIN Modular Inverter Air Cooled Chiller

Variable Refrigerant Flow

15A Operating Range Communication Wire Size 18-2 AWG / 300V THHN Cooling (Max) 118 F (48 C)

Heat Pump Air Conditioning Systems

SECTION SEQUENCE OF OPERATIONS FOR HVAC CONTROLS

MRVIII-C MRVIII-C. 4 way air return heat exchanger design. Two stages heat exchanger design. Double EEV design. Special Heat Exchanger Design

Water-Cooled Modular Chillers. Product Data Catalog. Standard and Total Access Modules MS010X, MS015X, MS020X, MS030X, MS040X, MS050X, MS070X, MS085X

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

ICP Inverter Air Conditioner Application Guideline

Innovative Ductless Mini Split Solution Submittal Data: GUHD24ND3FO/GKH24D3FI Job Name Location Date

Compact Design For Light Commercial Buildings. Benefit Points SMALL OFFICES HOTELS NEW SHOPS, RESTAURANTS. 1. Compact & Quiet design

ASHRAE 90.1 COMPLIANT 6 to 36 Tons

WJH4 Product Specifications

3 rd Generation of VRV. The professional solution for your professional project

AHU Plus. DX Air Handling Units

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

PAD3. Product Specifications. 13 SEER PACKAGE AIR CONDITIONER, 2 to 5 TONS Single Phase, 208/230 V, 60 Hz REFRIGERATION CIRCUIT

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

SAC Technical Data Book

Lennox Mini-Split Systems Year-Round Comfort and Performance

YORK AMICHI SERIES AIR-COOLED DC INVERTER SCROLL CHILLERS AND HEAT PUMPS

ICP Inverter Heat Pump Application Guideline

Product Guide. Wallmount. Air Conditioners & Heat Pumps

Product Data INDUSTRY LEADING FEATURES / BENEFITS

208/230V, 1-Phase. 208/230V, 460V 3-Phase. 208/230V, 460V 3-Phase

Unit Width. 900mm. Service Space Internal Header. 1st. Unit. 2nd. Coupling supplied as standard. Unit

PAJ3. Product Specifications

Daikin Inverter Ducted Systems

SHConDEMAND. True Redundancy. Heating. Cooling. Simultaneous. Efficient. Reliable

TECHNICAL SPECIFICATIONS

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller

VRF D4 PLUS System. Highlights. Digital Scroll Series. Dealer information. Commercial Air Conditioner Business Units Midea Group

SAMSUNG HVAC RESIDENTIAL & LIGHT COMMERCIAL MINI SPLIT AIR CONDITIONERS SINGLE & MULTI-ZONE

Method to test HVAC equipment at part load conditions

ECOi TM. Variable Refrigerant Flow (VRF), Multi-Zone, Heat Pump & Heat Recovery Systems

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

GP SERIES Packaged Chillers

Trailblazer air cooled scroll chillers

CONTROLLED CHILLED BEAM PUMP MODULE

Call us today! (800)

Call us today! (800)

Transcription:

DVM CHILLER Increase your flexibility. Get the best of two worlds. This easy to expand, modular unit combines the benefits of VRF and Chiller systems. Product Registration Required Conditions Apply 2018 Samsung HVAC

The ultimate combination of VRF and Chiller technologies. So what exactly is a VRF system? Glad you asked. Variable Refrigerant Flow (VRF) systems consist of outdoor units connected to multiple indoor units via refrigerant piping to provide cooling and heating to individual zones. The outdoor units can modulate capacity based on the requirements of the individual zones, thus saving energy by not always running at 100% capacity and improving occupant comfort by maintaining temperature as needed in each individual zone. The DVM Chiller works in a similar way, except it s connected to multiple third-party Fan Coil Units (indoor units) via water piping to provide cooling and heating to individual zones. Like VRF outdoor units, the DVM Chiller can modulate its capacity depending on the requirements of the various zones, which saves energy and improves occupant comfort. VS 49% space saving* *Comparison with conventional water-cooled chiller system (Cooling tower + Chiller + Boiler) and SAMSUNG DVM Chiller based on 160 tons.

Get a modular makeover. With a modular design and compact size, it reduces the time, cost, and effort to transport, move, and install. With a small footprint, it s easy to fit and combine multiple units even when there s limited space. A maximum of 16 DVM Chiller modules can be combined for up to 240 tons. Uses Samsung DC scroll compressors with flash injection technology for increased low ambient heating performance Compatible with Samsung central and local controls Optional Fan Coil Unit Control Kits and Fan Coil Interface Modules are available to control and integrate third-party fan coil units to Samsung central and local controls Advanced defrost logic to reduce defrost operation duration and frequency Three operation patterns: Standard, Rotation, and Efficiency, can be selected allowing DVM Chiller systems to be applied to various project requirements Optional settings to automatically adjust leaving water temperature based on outdoor ambient temperature or indoor ambient temperature Temperature of the delivered water from the DVM Chiller can be set between 14-77 F in cooling and 77-131 F in heating

DVM Chiller Controls and Accessories (sold separately) Module Controller MCM-A00N Required to operate the DVM Chiller DVM Chiller ON/OFF control (module/group) Operation mode, water outlet temperature setting Optional operation setting, module/group setting Weekly operation schedule setting FCU (Fan Coil Unit) Control Kit MIM-F00N Communication interface module between FCU Control Kit and upper-level controller Supports FCU Control Kit Only Maximum connection of 16 FCU Control Kits Used with MIM-F00N FCU Control Kits Requires MIM-F10N Interface Module FCU (Fan Coil Unit) Interface Module MIM-F10N Communication and control interfacing kit between 3rd party fan coil unit and Samsung control system Compatible with MWR-SH10N and MR-WE11N wired controllers Provides external contact input Outputs control signal for fan coil unit fan/water valve DVM Chiller Integrated System <Field Scope> DMS 2.5 FCU I/M FCU Kit H/M/L/Off, Valve On/Off Group-G1 75ºF FCU1 Touch centralized controller DVM Chiller MAIN UNIT 1 UNIT 2 Module controller FCU (Field supply) FCU3 4way1 DVM S VRF System On/Off VRFs Water Pump (Field supply) Control and monitor Samsung standard indoor units along with third-party fan coil units using a FCU control kit with the DMS 2.5 web interface.

Central Controls Samsung s Data Management Server (DMS) lets you monitor and control your on-site air conditioning needs remotely. It s the easiest and most convenient way to manage a large number of air conditioning units at once. DMS 2.5: 24-hour standalone web-server No special software required All management functions integrated Heat pump auto changeover logic DMS 2.5 + BACnet and LonWorks available BACnet and LonWorks gateways will wire and setup the same as DMS 2.5 DMS 2.5 MIM-D01AUN Additional control options available. Please refer to www.dvmdownload.com for all control options, features, and specifications.

DVM Chiller 208-230V, 3Ø SPECIFICATIONS - 120,000 168,000 MODEL OUTDOOR UNIT AG010KSVAFH/AA AG015KSVAFH/AA TONS NOMINAL 10 15 AMBIENT: 95 F ENTERING TEMPERATURE: 54 F LEAVING TEMPERATURE: 44 F 120,000 Btu/h 168,000 Btu/h PERFORMANCE POWER DIMENSIONS LEAVING TEMPERATURE: 105 F 128,000 Btu/h 182,000 Btu/h LEAVING TEMPERATURE: 120 F 120,000 Btu/h 171,000 Btu/h LEAVING TEMPERATURE: 105 F 84,000 Btu/h 90,000 Btu/h LEAVING TEMPERATURE: 120 F 80,000 Btu/h 85,000 Btu/h 11.20 10.10 LEAVING TEMPERATURE: 105 F 13.10 12.00 LEAVING TEMPERATURE: 120 F 10.40 9.80 LEAVING TEMPERATURE: 105 F 7.50 7.50 LEAVING TEMPERATURE: 120 F 6.30 6.50 20.50 18.80 ø / V / Hz 3 / 208-230 / 60 3 / 208-230 / 60 70.0 A 90.0 A 52.0 A 70.0 A 70 11/16 X 66 3/4 X 30 1/8 in. 70 11/16 X 66 3/4 X 30 1/8 in. 959.00 lbs. 959.00 lbs. SOUND PRESSURE LEVEL OUTDOOR 60 db(a) 62 db(a) OPERATING WATER TEMPERATURE OPERATING AMBIENT TEMPERATURE WATER SIDE HEAT EXCHANGER REFRIGERANT TYPE FACTORY CHARGE STANDARD 41-77 F 41-77 F WHEN USING BRINE 14-77 F 14-77 F 77-131 F 77-131 F 5-118 F 5-118 F -13-109 F -13-109 F 50A Cut Groove 50A Cut Groove 2 2 MIN. 15.8 / 15.8 16.8 / 16.8 NOMINAL 24.0 / 24.0 33.6 / 33.6 MAX. 48.0 / 48.0 67.2 / 67.2 72.0 gal. 100.8 gal. R410A R410A 40.0 lbs. 40.0 lbs. COMPRESSOR TYPE Inverter Driven Scroll (2) Inverter Driven Scroll (2) CONDENSER FAN CAPACITY (DRY / WET BULB: 17/15 F) EER (DRY / WET BULB: 47/43 F) COP (DRY / WET BULB: 17/15 F) IPLV VOLTAGE MAX. BREAKER MIN. CIRCUIT AMPACITY W X H X D WEIGHT CONNECTION TYPE QUANTITY WATER FLOW (GPM) ( / ) MIN. WATER SYSTEM VALUE FAN MOTOR (DRY / WET BULB: 47/43 F) MAX. EXTERNAL STATIC PRESSURE TYPE Propeller (2) Propeller (2) CFM (MAX.) 12,855 12,855 TYPE BLDC BLDC OUTPUT 630 X 2 W 630 X 2 0.32 in. WC 0.32 in. WC WARRANTY Product registration required. Conditions apply. The AHRI Certified mark indicates Samsung s participation in the AHRI Certification program. For verification of individual certified products, go to www.ahridirectory.org. DVM Pro Design software is available for at www.dvmdownload.com. Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.

DVM Chiller 460V, 3Ø SPECIFICATIONS - 120,000 168,000 MODEL OUTDOOR UNIT AG010KSVAJH/AA AG015KSVAJH/AA TONS NOMINAL 10 15 AMBIENT: 95 F ENTERING TEMPERATURE: 54 F LEAVING TEMPERATURE: 44 F 120,000 Btu/h 168,000 Btu/h PERFORMANCE POWER DIMENSIONS LEAVING TEMPERATURE: 105 F 128,000 Btu/h 182,000 Btu/h LEAVING TEMPERATURE: 120 F 120,000 Btu/h 171,000 Btu/h LEAVING TEMPERATURE: 105 F 84,000 Btu/h 90,000 Btu/h LEAVING TEMPERATURE: 120 F 80,000 Btu/h 85,000 Btu/h 11.20 10.10 LEAVING TEMPERATURE: 105 F 13.10 12.00 LEAVING TEMPERATURE: 120 F 10.40 9.80 LEAVING TEMPERATURE: 105 F 7.50 7.50 LEAVING TEMPERATURE: 120 F 6.30 6.50 20.50 18.80 ø / V / Hz 3 / 460 / 60 3 / 460 / 60 30.0 A 50.0 A 24.0 A 40.0 A 70 11/16 X 66 3/4 X 30 1/8 in. 70 11/16 X 66 3/4 X 30 1/8 in. 959.00 lbs. 959.00 lbs. SOUND PRESSURE LEVEL OUTDOOR 60 db(a) 62 db(a) OPERATING WATER TEMPERATURE OPERATING AMBIENT TEMPERATURE WATER SIDE HEAT EXCHANGER REFRIGERANT TYPE FACTORY CHARGE STANDARD 41-77 F 41-77 F WHEN USING BRINE 14-77 F 14-77 F 77-131 F 77-131 F 5-118 F 5-118 F -13-109 F -13-109 F 50A Cut Groove 50A Cut Groove 2 2 MIN. 15.8 / 15.8 16.8 / 16.8 NOMINAL 24.0 / 24.0 33.6 / 33.6 MAX. 48.0 / 48.0 67.2 / 67.2 72.0 gal. 100.8 gal. R410A R410A 40.0 lbs. 40.0 lbs. COMPRESSOR TYPE Inverter Driven Scroll (2) Inverter Driven Scroll (2) CONDENSER FAN CAPACITY (DRY / WET BULB: 17/15 F) EER (DRY / WET BULB: 47/43 F) COP (DRY / WET BULB: 17/15 F) IPLV VOLTAGE MAX. BREAKER MIN. CIRCUIT AMPACITY W X H X D WEIGHT CONNECTION TYPE QUANTITY WATER FLOW (GPM) ( / ) MIN. WATER SYSTEM VALUE FAN MOTOR (DRY / WET BULB: 47/43 F) MAX. EXTERNAL STATIC PRESSURE TYPE Propeller (2) Propeller (2) CFM (MAX.) 12,855 12,855 TYPE BLDC BLDC OUTPUT 630 X 2 630 X 2 0.32 in. WC 0.32 in. WC WARRANTY Product registration required. Conditions apply. The AHRI Certified mark indicates Samsung s participation in the AHRI Certification program. For verification of individual certified products, go to www.ahridirectory.org. DVM Pro Design software is available for at www.dvmdownload.com. Samsung HVAC maintains a policy of ongoing development, specifications are subject to change without notice.

SamsungHVAC.com CHLBR 03.2018 - V1