INSTALLATION & MAINTENANCE MANUAL

Similar documents
OPERATION & INSTALLATION MANUAL AIR PURIFICATION SYSTEM (APS300)

EcO 3 Ice ECO3ICE TM - ANTIMICROBIAL ICE PROTECTION ANTIMICROBIAL ICE PROTECTION FRANKE FOODSERVICE SOLUTIONS MODEL NUMBER PRODUCT OVERVIEW

VISUAL DISPLAY DISPENSER OWNERS MANUAL

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO-200/250

INSTALLATION MANUAL ICE/BEVERAGE DISPENSER MODEL: ENDURO VALVE

CH750, CH751 & CH951 CHILLERS

Model No. CZ2011O Oak Finish CZ2011C Cherry Finish CZ2011W Walnut Finish CZ2011B Black Finish DIGITAL QUARTZ INFRARED HEATER OWNER S MANUAL

CH250 AND CH251 CHILLERS

DR Series. Installation & Operations Manual. Model: DR-10 HIGH OUTPUT SHOCK TREATMENT OZONE GENERATOR

Operating Instructions

ICE DISPENSER. D45 and D90 Installation Manual. Release Date: August, 1995 Publication Number: Revision Date: March 27, 2014 Revision: D

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

INSTALLATION, OPERATION AND MAINTENANCE

Ozone + UV Sanitation

WHYNTER Compressor Cooling Beverage Refrigerator - Stainless Steel

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL

Industrial Dehumidifier Operating Instructions. Model: VG 1500

Because you re not like everyone else. PORTABLE CLEAR ICE MAKER IM200SS OWNER S MANUAL. Manual v1.0

DEHUMIDIFIER. User Manual 50BT, 70BT

Installation Guide. Manufactured for Aero-Spa, LLC Web:

MEDICAL FREEZER. Model FS24L INSTRUCTION MANUAL. Write Serial Number (on back of unit) here:

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Silicone Rubber Heating Tape with Adjustable Thermostat Control (HSTAT Series) Instruction Manual

HAMILTON ELECTRIC STOVE HEATER MODEL EF-BLT01 / EF-BLT04 / EF-BLT07 / EF-BLT08 OPERATION MANUAL

Instruction Manual. 36 in. and 42 in. Popcorn Staging Cabinets

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

Hot Water Dispensers HWD2, HWD3, HWD5. Table of Contents

WG545.9 WG575 WG575.1 EN F ES

IceBoss Pro. ElectroBoss IceBoss Pro Portable Home Ice Machine. Portable Home Ice Maker Ice Boss Pro Stainless

Installation and Operation Manual. 445 Procedures Cart. Page 3. Page 5. Page 8. Page 10. Important Information Page 2. Installation.

OPERATING AND INSTALLATION MANUAL

IMPORTANT SAFETY INFORMATION:

HM & HM Ultra Thin Micathermic Heater. Model No. HM / HM Soleus Air International

NO VENTING REQUIRED 120V AC;

OWNERS MANUAL For IN ROOM BREWING SYSTEM MODEL REFILLABLE CAPSULES K901. Includes: Installation Use & Care Servicing Instructions

OPERATING AND INSTALLATION MANUAL

Prime chiller. Inline Chiller. Instructions for Models #2645,2646

Installation, Operation, and Maintenance Manual

Operator s Manual. IP-100 Immersion Probe Cooler

Operator s Manual. Histology Bath

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS

OPERATORS MANUAL FOR Mi-T-M CORONA DISCHARGE OZONE GENERATORS

ICE COOLED DISPENSER ALTA 1522 DROP-IN DISPENSER

Operator s Manual. Model G32-S Model G32-E Disinfection Soak Stations

YOUR PORTABLE AIR PURIFIER

HGW-308R Wall Mountable Micathermic Heater w/ Remote. Model No. HGW-308R Soleus Air International

Mobile Hot Food Merchandiser Series. Series: MHB Operation Manual

Projection Alarm Clock USER GUIDE

Superdryer Dehumidifiers

MODEL 925W FEATURES: ELECTRICAL DATA: DIMENSIONS: SHIPPING INFORMATION: FOOD WARMING/ MERCHANDISING CABINET

Series Automatic Hand Dryer. Operating Instructions for the User & Installation Instructions for the Licensed Installer

Installation, Operation & Service Manual

OWNER S MANUAL ELECTRIC FIREPLACE INSERT. Model No.: WESTERN (EF42D-45D) WARNING CAUTION

BLT-999W-2 Item # 60757

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

BEFORE USE, PLEASE READ AND FOLLOW ALL SAFETY RULES AND OPERATING INSTRUCTIONS.

(HSTAT Series) Instruction Manual

26 LB CAPACITY ICE MAKER

OWNER S MANUAL. FLAT PANEL FIREPLACE HEATER Model Number: Serena (EF202A) WARNING CAUTION

IM-440C IM-660C IM-1108C

BEFORE FIRST USE: TABLE OF CONTENTS

INSTALLATION. and INSTRUCTION MANUAL. for QUALITY AIR BREATHING SYSTEMS. Model ABM - 715

Corning LSE 6L Digital Water Bath


Ice Maker. De Glaçons. Portátil PIM9W. Use & Care Guide Guide d utilisation et d entretien Manual de uso y cuidado. Portable.

IMPORTANT SAFETY INFORMATION:

SAVE THESE INSTRUCTIONS

WET/DRY VACUUM. QUEST for Continuous Improvement Windsor s Quality Management System is Certified ISO MODEL: T1. Operating Instructions (ENG)

Owner s Manual PUH1500. Electric Umbrella Heater. Model Number: Model Number Part Number. Quality checked by: R00

Owner / Operator Use and Care Guide I SERIES 224 ICE CUBE MACHINE

Wrap-Around TOTE Tank / IBC Heaters (TOTE and TOT Series)

OZX-300ST Ozone Generator

AI-215 Series Portable Ice Maker

CABINET INFRARED HEATER

Automatic Water System Pump SERIES

Instruction Manual. Bucket Oil Pump

IMPORTANT SAFETY INFORMATION:

ICE/BEVERAGE DISPENSER

PUA 80. Lietošanas pamācība Instrukcija Kasutusjuhend. ja ko zh cn. Printed: Doc-Nr: PUB / / 000 / 01

CHILLER. Model CH3000. Operator s & Installation Manual

ICE MAKER. 26 Lbs. Capacity HME010019N. Before using your Ice Maker, please read this manual.


TG-10 Wall Mount Installation and Operation Manual. High Output Ozone Generator

Owner & Operator s Manual. Table of Contents

SAFETY ALERT SYMBOLS SAFETY PRECAUTIONS

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Item Model Description Voltage Amps Hz

Alice. In Wall Recessed Electric Fireplace Model Number: (EF172B, EF173B, EF174B, EF175B, EF176B) OWNER S MANUAL

User Manual / Installation Instructions

VENTLESS EXHAUST HOOD OPERATORS MANUAL AND PARTS LIST REV. MAY 2016

USER MANUAL SAVE THESE INSTRUCTIONS

IMpORTANT SAFETy INSTRUcTIONS

Store Name: Location: Date Purchased: Serial Number (located on back of unit):

Installation and Operation Instructions Luxury Towel Warmer Free Standing or Wall Mounted

REFRIGERATOR SAFETY. Your safety and the safety of others are very important.

K Specifications. Max. Water Volume

ICE MAKER. Model: IM-101 INSTRUCTION MANUAL

VANTAGE. Installation Manual. Release Date: April 16, 2003 Publication Number: INS Revision Date: January 22, 2015 Revision: E

Portable Heated Black Glass Shelves

Transcription:

INSTALLATION & MAINTENANCE MANUAL EcO 3 Ice ANTIMICROBIAL PROTECTION FOR COMMERCIAL ICE MACHINES MODEL: X1 X4 X8 X16 Model X4 Shown

IMPORTANT SAFETY INFORMATION DANGER WARNING CAUTION NOTICE EXPLANATION OF SAFETY AND NOTICE SYMBOLS DANGER indicates a hazardous situation which, if not avoided, WILL result in death or serious injury. WARNING indicates a hazardous situation which, if not avoided, COULD result in death or serious injury. CAUTION indicates a hazardous situation which, if not avoided, COULD result in minor or moderate injury. NOTICE is used to address practices not related to physical injury. READ AND SAVE THESE INSTRUCTIONS DANGER Energized electrical circuits prest a life-threating hazard of electric shock, explosion, or arc flash. NEVER hose down or clean with water jet. ALWAYS disconnect device from power IMMEDIATELY if bare wires or other electrical conductors are exposed. - ALWAYS sure all electrical circuits are disconnected and discharged, with an appropriately rated voltage detecting device, before performing service, maintance, or installation work. ALWAYS follow all national and local standards, laws, and codes, as well as all applicable safe electrical work practices. Failure to follow these safety instructions WILL result in death or serious injury. WARNING Unauthorized modifications, repairs, or use poses a hazard in the form of an improperly functioning device. ONLY for commercial use. NEVER make ANY modifications that are not authorized in writing by Franke. NEVER remove any labels from the device. ALWAYS replace ANY labels that have be removed or damaged IMMEDIATELY. ONLY use original equipmt manufacturer (OEM) parts wh performing service, maintance, or installation work. NEVER operate with factory installed parts or componts removed. NEVER use for other than intded use. Failure to follow these safety instructions COULD result in death or serious injury, as well as property damage or void of warranty. These instructions are intded for qualified persons ONLY. Use by others creates an unsafe condition. ONLY persons who are certified technicians or trades persons with the requisite knowledge, skills, ability, and training, MUST perform service or installation work. ALWAYS keep out of the reach of childr. ONLY allow access to device by trained personnel who have read this manual. Failure to follow these safety instructions COULD result in death or serious injury, as well as property damage or void of warranty. 2/16

IMPORTANT SAFETY INFORMATION This device gerates ozone (O3) in the form of gas, which poses a hazard in excess quantities. O3 gas is toxic and corrosive. It accelerates burning, is heavier than air and oxyg, has an acrid odor, and is unstable. ONLY operate in well vtilated areas. ALWAYS disconnect device from power IMMEDIATELY if an unusually strong acrid odor is detected. ALWAYS seek fresh air IMMEDIATELY if respiratory irritation is expericed. Seek medical atttion if necessary. Disconnect device from power IMMEDIATELY. - ALWAYS sure all electrical circuits are disconnected before performing service, maintance, or installation work, to avoid accidtal geration of ozone gas. ALWAYS follow all national and local standards, laws, and codes, as well as all applicable, safe O3 work practices. ALWAYS sure all factory installed parts and componts are re-installed properly and are in good condition after performing service, maintance, or installation work. Failure to follow these safety instructions COULD result in death or serious injury. NOTICE NEVER use inappropriate tools, processes, or procedures. Damage to componts of device can occur. Follow these instructions EXACTLY to avoid property damage or void of warranty. NEVER discard any loose parts received with device. They may be required for proper and safe installation and operation. EcO 3 Ice SPECIFIC SAFETY INFORMATION WARNING Installation of the device on unapproved ice machines could result in damage to the machine, creating a hazard of small parts tering the ice during or after formation. NEVER install device on, or in line with, unapproved ice machines or equipmt. ALWAYS sure model compatibility of device and ice machine before installing. ALWAYS contact Franke to verify approved usage and model compatibility, if unsure (refer to Contact Information, Page 16). Failure to follow these safety instructions COULD result in death or serious injury, as well as property damage or void of warranty. CAUTION Improper installation prests a risk of respiratory and/or digestive irritation from ozone (O 3 ) gas. NEVER install device on an ice machine without a dedicated water supply line. ALWAYS sure device does NOT feed drinking water dispsers. Some are built into, or are attached to, some ice machines. ALWAYS sure the flow rate of the model of the device is appropriate for the ice machine to which it is being installed. Failure to follow these safety instructions COULD result in mild or moderate injury, as well as property damage or void of warranty. 3/16

EcO 3 Ice SPECIFIC SAFETY INFORMATION NOTICE Dissolved ozone (O 3 ) is gerated by the device from water. Under normal conditions, insufficit quantities of ozone gas are gerated to create a hazardous condition. O 3 gas can be detected by humans (by smell) at a level as low as 0.003 partsper-million (ppm), the odor threshold. It is normal and expected to be able to detect a very mild acrid odor emanating from the areas around the connected ice machine s distribution tubes, reservoir, evaporator plates, and ice bin. - Occupational Safety and Health Administration (OSHA) exposure limits for O 3 are as follows: * Long term = 0.10 ppm for 8 hours * Mid term = 0.20 ppm for 2 hours * Short term = 0.30 ppm for 15 minutes The device is designed to gerate O 3 gas below the listed limits wh installed, used, and maintained properly. O 3 could diminish the effectivess of some chemical products used during cleaning, sanitizing, or descaling cycles. ALWAYS unplug device before performing maintance work. Iron and manganese in the water supply may cause harmless discoloration of internal plastic parts in ice machines under certain conditions wh ozone (O 3) is introduced. If this condition arises, additional water filtration may be required. NEVER expose device to extreme heat or op flame. NEVER immerse device in water. Clean exterior of device with soft cloth. Do not use harsh or abrasive cleaners. 4/16

CONTENTS Important Safety Information... 2 EcO3Ice Specific Safety Information... 3 Key Componts... 6 Head - All Models... 6 X1/ X4... 6 X16... 7 X8... 7 Specifications... 8 Certifications... 9 Installation... 9 Before Installing... 9 Installing the Device... 10 Maintance... 12 Expected Cartridge Life... 12 Replacing the Cartridge... 12 Troubleshooting... 14 Disposal... 15 Warranty Information... 15 Contact Information... 16 5/16

KEY COMPONENTS Head - All Models 3 2 4 ITEM # PART NAME 1 Gre LED - Power 2 Yellow LED - Replace Soon 3 Red LED - Replace Now 4 Serial Number Label 5 Model Number (Prefix) Table 1 Fig. 1 5 1 X1/ X4 1 2 ITEM # PART NAME 1 3/8" Water Line Inlet * 2 3/8" Water Line Outlet * 3 Replaceable Cartridge Table 2 * Some models include optional fittings 3 Fig. 2 6/16

KEY COMPONENTS X16 4 1 2 ITEM # PART NAME 1 1/2 Water Line Inlet * 2 1/2 Water Line Outlet * 3 Replaceable Cartridge 4 1/2" Water Bypass Table 3 * Some models include optional fittings 3 Fig. 3 X8 ITEM # PART NAME 1 1/2" Water Line Inlet * 2 1/2" Water Line Outlet * 3 Replaceable Cartridge Table 4 1 2 * Some models include optional fittings 3 Fig. 4 7/16

SPECIFICATIONS Specification Model X1 Model X4 Model X8 Model X16 Application Most flaker ice machines Most cube ice machines Most high volume cube ice machines Most high flow cube ice machines Water Flow 0.03 gpm to 0.34 gpm 0.10 Lpm to 1.30 Lpm 0.34 gpm to 1.30 gpm 1.30 Lpm to 4.90 Lpm 0.34 gpm to 1.30 gpm 1.30 Lpm to 4.90 Lpm 1.30 gpm to 4.20 gpm 4.90 Lpm to 16.00 Lpm Clean, potable water ONLY Recommded hardness 300 ppm CaCO 3 Water Supply Minimum 20 psi / Maximum 125 psi Minimum 1.37 bar / Maximum 8.62 bar Minimum 40 F / Maximum 86 F Minimum 4 C / Maximum 30 C 100-240 Volts, 50/60 Hertz, 1 Phase 24 Volts, 1.25 Amps integrated transformer & power cord included Electrical 1.25 Amps 1.67 Amps (Maximum by Phase) 30 Watts 30 Watts 30 Watts 40 Watts (Maximum by Phase) Ambit Air Minimum 40 F / Maximum 100 F Minimum 4 C / Maximum 38 C Table 5 8/16

CERTIFICATIONS Sanitation (to NSF 2 & 61 & 372), CE, TUV, ETL, RoHS, WEEE WRAS approved for cold water use only in UK. (4 C - 23 C) US EPA EST. NO. 089373-MA-001 Table 6 INSTALLATION Before Installing WARNING Installation of the device on unapproved device and ice machine before installing. ice machines could result in damage to the ALWAYS contact Franke to verify approved machine, creating a hazard of small parts usage and model compatibility, if unsure tering the ice during or after formation. (refer to Contact Information, Page 16). NEVER install device on, or in line with, unapproved ice machines or equipmt. ALWAYS sure model compatibility of Failure to follow these safety instructions COULD result in death or serious injury, as well as property damage or void of warranty. Observe these guidelines to sure the device functions and performs optimally. 1. Select a location for device so: It will be in an upright position. It will be within 3 ft (1 m) of the ice machine water inlet. LED lights and cartridge are visible and accessible. Equipmt or objects will not press against the device. 2. ONLY use one (1) EcO 3 Ice device per ice machine. 3. DO NOT connect to water lines which feed more than one ice machine. 4. DO NOT connect to water lines which feed beverage or water dispsers. 5. DO NOT connect to water lines which feed condser cooling systems of water-cooled ice machines. 9/16

INSTALLATION Before Installing (continued) 6. Ensure adequate back-flow protection is provided (by others) to comply with all national and local standards, laws, and codes. 7. Ensure EcO 3 Ice will be the last water treatmt device installed on the water line before the ice machine water inlet. 8. It is highly recommded that a water shut-off valve be installed before and near the device. 9. For best results, clean ice machine, ice bins, and ice dispsers thoroughly before installing. Installing the Device The step numbers below correspond to the image step numbers on the next page. 1. Mount device on wall, or other suitable surface, within 3 ft (1 m) of ice machine water inlet. Use appropriate hardware (not provided). 2. Insert appropriate size of beveragegrade tubing into the fittings on the IN and OUT sides of device. Do NOT use more than 3 ft (1 m) of tubing on the 'OUT' side. Some models include optional fittings. 3. Attach the IMPORTANT label inside ice machine, near the power switch, so it can be se wh cleaning, sanitizing, or descaling is initiated. 4. Install cartridge (refer to Replacing the Cartridge, Pages 12 13). 5. Ensure all plumbing connections are secure and leak-free, from shut-off valve to ice machine water inlet. 1 3 ft (1 m) maximum distance and lgth of tubing 10 /16

INSTALLATION 2 3 IMPORTANT! Always unplug the EcO 3Ice device before ice machine cleaning, sanitizing, or descaling. Plug in the device wh the cycle is complete. 4 Refer to Replacing the Cartridge, Pages 12 13 5 11 /16

MAINTENANCE Expected Cartridge Life The EcO 3 Ice replaceable cartridge is designed to typically last: - 2 years 100 to 300 lb - 1 year 301 to 1000 lb - 9 months 1001 to 1500 lb - 6 months 1501 lb and larger Yellow LED Red LED Protection DIMINISHED Replace SOON Protection EXPIRED Replace NOW Hard water, or other factors, may short cartridge life. Two (2) Replace Cartridge LED indicators are prest on the head of the device to warn wh the cartridge is nearing the d of its effective life cycle. Replace cartridge at the expected life cycle intervals shown, or wh the Yellow or Red LED indicators warn to do so, whichever comes first. Replacing the Cartridge The step numbers below correspond to image step numbers below and on the next page. 1. IMPORTANT! Unplug the device, and close the water shut-off valve. 2. Hold head of device steady, untwist the used cartridge, pull to remove, and dispose of appropriately. 3. Record date of installation on the label provided on new cartridge. 4. Remove and discard protective cap. Hold head of device steady, push cartridge into head, and twist. Line up notches on cartridge and head. 5. Plug device into outlet, op the water shut-off valve, and sure the gre LED on the head of the device is illuminated. If not, refer to Troubleshooting, Page 14. 1 12 /16

MAINTENANCE 2 3 REPLACE CARTRIDGE Installation Date 4 5 13 /16

TROUBLESHOOTING LED INDICATORS STATUS REMEDY Gre (solid) Gre (flashing)* Power ON Ozone being gerated Device operating properly Yellow (flashing) Protection diminished Replace cartridge soon Red (solid) Protection expired Replace cartridge now Yellow (solid) and Red (flashing) Yellow (flashing) and Red (solid) Yellow (flashing) and Red (flashing) No ozone being gerated No ozone being gerated Cartridge installation issue No ozone being gerated Cartridge installation issue Leak in water supply line Replace cartridge now Replace cartridge now If rectly replaced, remove and reinstall Replace cartridge now If rectly replaced, remove and reinstall Repair leak, unplug device, and plug in device again If these steps do not resolve the issue, contact Franke for support. (Refer to Contact Information, Page 16) Please have the model number of the device available wh calling. (Refer to Key Componts, Head - All Models, Page 6) *NOTE: Gre flashing LED indicator is included only on devices manufactured after April 1, 2017. Previous versions do not include this feature. 14 /16

DISPOSAL Special regulations apply wh disposing of electrical appliances. The customer is responsible for proper disposal of the delivered product after the d of its service life at the customer s own expse, in accordance with all legal regulations for the giv region, state, or country. This does not apply to the replacemt cartridges for the device. WARRANTY INFORMATION Franke Foodservice Solutions ( Franke ) warrants new equipmt manufactured in Franke designated facilities to be free of defects due to poor materials or workmanship for the period of time listed below (following the date of purchase): EcO 3 Ice head - One (1) year parts only. EcO 3 Ice cartridge - Thirty (30) days parts only. Exclusions: Certain Franke parts that are expdable by nature and that need to be replaced frequtly may not be covered. Franke is not liable under these warranties for repairs or damages due to improper operation, attempted repairs or installation by unauthorized persons, alterations, abuse, fire, flood, or acts of nature. Additionally, this warranty may be voided in the case of: Failure to follow Franke instructions for use, care, or maintance. Removal, alteration, or defacing of Franke-affixed serial number and other labels. Mechanical damage. Use of fluids other than clean, potable water. Use with unapproved ice machines or equipmt. This warranty is conditional upon Franke receiving notice of any defect subject to this warranty within thirty (30) days of its original discovery by the Buyer. 15 /16

CONTACT INFORMATION Asia Franke Foodservice Systems Asia Co., Ltd. Phone +852 3184 1955 www.franke.asia Europe Franke Foodservice Systems EMEA Phone +49 7761 5533 5780 www.franke.com The Americas Franke Foodservice Solutions Inc. Phone +1 615 462 4000 www.franke.us Documt Part # 19009595, Rev. B, July 24, 2017 2017 Franke Foodservice Solutions, Inc. This media is the confidtial and proprietary property of Franke Foodservice Solutions, Inc. and shall not be reproduced in any form of media without the express writt permission of Franke. Trademarks used are the property of their respective owners. Due to continuous product developmt, Franke reserves the right to make changes in design and specifications without prior notice. Printed in the USA under licse by Franke Technology and Trademark Ltd., Switzerland.