LRP14HP. Residential - R-410A L RP 14 HP 36 P A MODEL NUMBER IDENTIFICATION. Bulletin No November 2016 Supersedes October 2016

Similar documents
LRP14AC. SEER to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Optional Electric Heat - 5 to 20 kw. Residential - R-410A

LRP14GE. SEER AFUE - 81% 2 to 5 Tons Cooling Capacity - 22,600 to 57,000 Btuh Input Gas Heating Capacity - 54,000 to 126,000 Btuh

LRP14DF. Dual-Fuel Residential - R-410A L RP 14 DF X P A MODEL NUMBER IDENTIFICATION

Rooftop Units 60HZ. PACKAGED HEAT PUMPS 13HPP / rhp13 PRODUCT SPECIFICATIONS 13 HPP 36 A P - 1 A RHP 13 A 36 T - 1 A MODEL NUMBER IDENTIFICATION

13 GEP A L P - 1 A

15CHPX. DAVE LENNOX SIGNATURE COLLECTION Residential - R-410A - Variable Speed Blower

RGE 13 A T - 1 A

2 shp 13 lc 1 36 t - 1 a

PRPDF16 PRODUCT SPECIFICATIONS PRP DF P A SINGLE STAGE GAS VALVE TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

DRY CHARGE UNITS. 1.5 to 5 Tons. HEAT PUMP OUTDOOR UNITS lps13dc PRODUCT SPECIFICATIONS L P S 13 DC MODEL NUMBER IDENTIFICATION

MERIT Series R-410A - Upflow / Horizontal

Nominal Capacity 024 = 7 kw (2 tons) 036 = 10.5 kw (3 tons) 048 = 14 kw (4 tons) 060 = 17.5 kw (5 tons)

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 18,000 to 60,000 Btuh AIR CONDITIONERS ML14XC1 PRODUCT SPECIFICATIONS

MERIT Series R-410A. SEER up to HSPF up to to 5 Tons Cooling Capacity - 18,000 to 61,000 Btuh Heating Capacity - 17,500 to 58,500 Btuh

MERIT Series R-410A - Upflow / Horizontal

T-SERIES SPLIT SYSTEM UNITS R-410A - 60 HZ. EER up to to 20 Tons Cooling Capacity - 71,000 to 236,000 Btuh AIR CONDITIONERS TS

MERIT SERIES Up Flow / Horizontal

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

T P A 120 S 4 S N 1 Y

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

XC16. ELITE SERIES R 410A Two Stage Compressor SilentComfort Technology A I R C O N D I T I O N E R S

T S A 048 S 4 N 4 1 T

XC17. DAVE LENNOX SIGNATURE COLLECTION R-410A - SilentComfort Technology. SEER up to to 5 Tons Cooling Capacity - 21,800 to 59,000 Btuh

Healthy Climate Whole-Home Dehumidifier. Nominal Capacity - 70 to 130 pints per day INDOOR AIR QUALITY HCWHD PRODUCT SPECIFICATIONS.

DAVE LENNOX SIGNATURE COLLECTION Variable Capacity - Precise Comfort Technology

14HPX MERIT SERIES R 410A H E A T P U M P O U T D O O R U N I T S

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

CB X 32 mv

14 AC x

T P A 048 S 4 N 4 1 T

Visit us at For the latest technical information,

Specially Designed. SilentComfort Fan Guard. Visit us at For the latest technical information,

ELITE Series R-410A - Two-Stage Compressor

ELITE Series Variable Capacity

13HPD MERIT SERIES R 22 H E A T P U M P O U T D O O R U N I T S

DAVE LENNOX SIGNATURE COLLECTION R-410A Ready - Multi-Position - Variable Speed

T-SERIES COMMERCIAL SPLIT SYSTEMS R-410A - 60 HZ

DAVE LENNOX SIGNATURE COLLECTION WITH SILENTCOMFORT TECHNOLOGY

DAVE LENNOX SIGNATURE COLLECTION Lo-Boy - Variable Speed Blower

T CLASS SPLIT SYSTEM UNITS Standard Efficiency - R-410A - 60 HZ

ELITE Series Variable Capacity

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

LGH/LCH WARNING. CAUTION Danger of sharp metallic edges. Can cause injury. Take care when servicing unit to avoid accidental contact with sharp edges.

Corp L2 Revised

icomfort Residential Communicating Control System Equipment Interface Module (EIM)

SL280DFV. DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

DAVE LENNOX SIGNATURE COLLECTION PureAir S Air Purification System

TECHNICAL SPECIFICATIONS

Product Data. 50HS Single-Package Heat Pumps to 5 Nominal Tons

TECHNICAL SPECIFICATIONS

High Heat COP. High/Low Stage

B24/C22/24 COILS BLOWER COIL UNITS ENGINEERING DATA. Bulletin # June 1994 Supersedes August B24 Blower Unit (With Optional Electric Heat)

MERIT SERIES Downflow

AC, HP and Air Handler Units Up to 20 Tons. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

DAVE LENNOX SIGNATURE COLLECTION Downflow - Two-Stage Heat - Variable Speed Blower

DAVE LENNOX SIGNATURE COLLECTION Humiditrol Whole-Home Dehumidification System

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

CB18/CBS18 Bulletin # September 1994 Supersedes August 1986

PRPHP16 PRODUCT SPECIFICATIONS PRP HP P A TWO STAGE COMPRESSOR VARIABLE SPEED BLOWER MINOR REVISION SEQUENCE A = 1ST GENERATION

Commercial High-Efficiency Condensing Units

Lennox 8 Series Single Zone - R-410A

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

48GS HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING/ ELECTRIC COOLING UNITS

LRP14HP/LRP14DF/LRP14AC/LRP14GE/LRP16GE/LRP16HP SERIES UNITS

Product Data. Fig. 1 - Unit 50VR -A

Zoning System for Residential Communicating, Variable Air Volume Heating/Cooling Systems

UNIT INFORMATION. Corp L7. Gauge Manifold Attachment... Page 30 Parts Arrangement... Page 8

48GS(N) STANDARD EFFICIENCY 48GX(N) HIGH-EFFICIENCY SINGLE-PACKAGE GAS HEATING ELECTRIC COOLING UNITS

Commercial High-Efficiency Condensing Units

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

DCG Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

DCC Series. Submittal Data Form. 7½- to 12½-Ton Three-Phase Packaged Air Conditioners

icomfort Residential Communicating Control System icomfort Touch Communicating Thermostat

IMPORTANT CB26UH CBX26UH. Service Literature. CB26UH and CBX26UH Series Table of Contents. Model Number Information... 2

P8SE Series. 14 SEER, Single Phase Packaged Air Conditioner TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 3, 4, 5 Ton Units

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

ELITE SERIES Downflow - High Efficiency Blower Motor

50Hz AC, HP and Air Handler Units Up to 70 kw. Commercial Split Systems. Reliable, cost-effective and servicefriendly split systems inside and out

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

OHR23. ELITE SERIES Horizontal/Downflow. AFUE - Up to 83.5% Input - 105,000 to 154,000 Btuh Nominal Add-on Cooling - 2 to 5 Tons O HR 23 Q 3/4-105/120

MACH N-407 Heat Pump Air-Cooled Chiller

Product Data. 50LJS/TJS Single- Package. Features / Benefits. Rooftop Units - 50 Hz 6 to 12 Nominal Tons

Performance and rugged durability. Commercial Split Systems Up to 20-Ton TSA/TPA Models

Product Data. Features/Benefits. 50HS Single-Package Heat Pump Units 50 Hz

JOB NAME: LOCATION: PURCHASER: ENGINEER: SUBMITTED TO: FOR: REFERENCE [ ] APPROVAL [ ] CONSTRUCTION [ ] SUBMITTED BY: DATE:

SKYPAK II, 3 Ton Series, gives you a

T-CLASS. Commercial Air Conditioners and Heat Pumps TSA/TPA Models UP TO 16.0 SEER AND 9.7 HSPF. Performance and rugged durability

DCC Commercial. Submittal Data Form. 7½ - 12½ Ton Packaged Air Conditioners Up to 11.3 EER Cooling Capacity: 88, ,000 BTU/h

HIGH EFFICIENCY AIR HANDLER

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

DSC Series. Submittal Data Form. 3-5 Ton Packaged Air Conditioner 14 SEER / Up to 12.0 EER

True performance and rugged durability Commercial Air Conditioners and Heat Pumps TSA/TPA Models. Up to 15.0 SEER, and 9.0 HSPF

HIGH EFFICIENCY TWO-STAGE ECONET ENABLED AIR HANDLER

PACKAGE AIR CONDITIONER

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

Call us today! (800)

Transcription:

PA C KA G E D H E AT P U M P LRP4HP Residential - R-40A Bulletin No. 07 November 06 P R O D U C T S P E C I F I C AT I O N S Supersedes October 06 SEER - 4.00 HSPF - 8.00 to 5 Tons Cooling Capacity -,600 to 57,000 Btuh Heating Capacity -,000 to 56,000 Btuh Optional Electric Heat - 5 to 0 kw MODEL NUMBER IDENTIFICATION L RP 4 HP 6 P - - A Brand L = Lennox Minor Revision Sequence A = st Generation Product Type RP = Residential Packaged Unit Nominal SEER 4 = 4 SEER Unit Type HP = Packaged Heat Pump Major Revision Sequence = st Generation Voltage P = 08/0V-phase-60hz Nominal Cooling Capacity 4 = tons 0 =.5 tons 6 = tons 4 =.5 tons 48 = 4 tons 60 = 5 tons

FEATURES CONTENTS Blower Data... 0 Cooling Ratings... Dimensions - Accessorie... 4 Dimensions - Unit... Electrical/Electric Heat Data... 8 Electric Heat Capacities... 8 Features... Field Wiring... 9 Heating Ratings... Installation Clearances... 5 Model Number Identification... Optional Accessories... 7 Specifications... 6 WARRANTY Compressor - Ten year limited warranty in residential installations and five years in non-residential installations. All other covered components - Five years in residential installations and one year in non-residential installations. Refer to Lennox Equipment Limited Warranty certificate included with unit for specific details. APPROVALS AHRI Certified to AHRI Standard 0/40-008. Units are design certified by ETL Intertek. Heating ratings are according to Department of Energy (DOE) test procedures and Federal Trade Commission (FTC) labeling regulations and are certified by AHRI. Cooling system rated according to DOE test procedures. Units are ETL certified for the U.S. and Canada. Packaged unit and components within bonded for grounding to meet safety standards required by UL. Optional electric heaters are ETL listed for the US and Canada and are rated and tested according to DOE test procedures and FTC labeling regulations. Each unit test operated at the factory before shipment ensuring dependable operation at start-up. REFRIGERATION SYSTEM R-40A Refrigerant Non-chlorine, ozone friendly, R-40A. Unit pre-charged with refrigerant. See Specifications table. Indoor and Outdoor Coils Copper tube with aluminum fin coils. Anti-Microbial Indoor Coil Drain Pan Anti-Microbial additive resists growth of mold and mildew on drain pan which improves indoor air quality and reduces drain line blockage. Outdoor Coil Fan Weather protected heavy duty outdoor coil fan motor with coated steel fan blades for long life. Internally mounted. Totally enclosed motor. Fan guard constructed of corrosion-resistant coated steel. Reversing Valve 4-way interchange reversing valve effects a rapid change in direction of refrigerant flow resulting in quick changeover from cooling to heating and vice versa. High Pressure Switch Shuts off unit if abnormal operating conditions cause the discharge pressure to rise above setting. Protects compressor from excessive condensing pressure. Automatic reset. Loss of Charge Switch Provides loss of charge protection by shutting off unit if liquid pressure falls below setting. Optional Accessories Drain Pan Overflow Switch Monitors condensate level in drain pan, shuts down unit if drain becomes clogged. APPLICATIONS Designed for outdoor installations at ground level or rooftop for residential applications. LRP4HP - to 5 Ton Heat Pump / Page

FEATURES SCROLL COMPRESSOR Compressor features high efficiency with uniform suction flow, constant discharge flow and high volumetric efficiency and quiet operation. Compressor consists of two involute spiral scrolls matched together to generate a series of crescent shaped gas pockets between them. During compression, one scroll remains stationary while the other scroll orbits around it. Gas is drawn into the outer pocket, the pocket is sealed as the scroll rotates. As the spiral movement continues, gas pockets are pushed to the center of the scrolls. Volume between the pockets is simultaneously reduced. When pocket reaches the center, gas is now at high pressure and is forced out of a port located in the center of the fixed scrolls. During compression, several pockets are compressed simultaneously resulting in a smooth continuous compression cycle. Continuous flank contact, maintained by centrifugal force, minimizes gas leakage and maximizes efficiency. Scroll compressor is tolerant to the effects of slugging and contaminants. If this occurs, scrolls separate, allowing liquid or contaminants to to be worked toward the center and discharged. Low gas pulses during compression reduces operational sound levels. Compressor motor is internally protected from excessive current and temperature. Compressor is installed in the unit on resilient rubber mounts for vibration free operation. Optional Accessories Compressor Crankcase Heater Protects against refrigerant migration that can occur during low ambient operation. Compressor Hard Start Kit Single-phase units are equipped with a PSC compressor motor. This type of motor normally doesn t need a potential relay and start capacitor. In conditions such as low voltage, this kit may be required to increase the compressor starting torque. CABINET Conditioned areas insulated with foil faced insulation to minimize heat loss and reduce operating sound levels. Powder paint for maximum durability. Easy service access. Steel louvered panels provides complete coil protection. Airflow Choice Units are shipped in horizontal configuration and can be field converted to downflow (vertical) airflow with optional Downflow Conversion Kit. Electrical Inlets and Service Valves Field wiring inlets are located in one central area of the cabinet. See dimension drawing. Gauge ports are located inside the cabinet. Optional Accessories Downflow Conversion Kit Required for field conversion to downflow (vertical) air. Kit consists of duct covers to block off horizontal air openings on side of unit. Required for field conversion to downflow (vertical) air. Kit consists of duct covers to block off horizontal air openings on side of unit. Kit also includes drain pan overflow switch to monitor condensate level in drain pan, shuts down unit if drain becomes clogged. Lifting Brackets Available to facilitate rigging of the unit. Clip Curb (Full Perimeter) Mates to unit. Roof curb can be assembled using interlocking tabs to fasten corners together. No tools required. Available in 8 and 4 inch heights. Shipped knocked down. Adjustable Pitch Roof Curb (Full Perimeter) Fully adjustable pitch curb provides a level platform for packaged units allowing flexible installations on roofs with sloped or uneven angles. Adjustable from / to 6/ pitch. Unit hold-down brackets secure packaged unit to curb. Constructed of heavy-gauge galvanized steel with fully welded seams and corners. Rounded corners on flange prevent damage to roof shingles. Built-in drip edge. IAPMO/UMC listed. CBC 0 compliant (California). Seismic rating - Ss=.7 Ip=.5, wind rating - 55mph. Maximum load rating 800 lbs. LRP4HP - to 5 Ton Heat Pump / Page

FEATURES SUPPLY AIR BLOWER Direct Drive Blower Each blower wheel is statically and dynamically balanced. Multi-speed, direct drive blower motor on 4 and 48 models. Constant-torque ECM direct drive motor on the 4, 0, 6 and 60 models. Change in blower speed is easily accomplished by simple wiring change on blower motor. Blower assembly easily removed for servicing See Blower Performance tables. AIR FILTER (required) Filters are not furnished - must be field provided. Internal Filter Rack Kits Available for in. thick filters. Kit contains filter rails for mounting filters internal to unit. Filters must be field provided. Filters are available separately. ELECTRIC HEAT (5-0 KW) Field install internal to unit cabinet. Available in several voltages and kw sizes. Helix wound nichrome heating elements exposed directly in air stream resulting in instant heat transfer, low element temperatures and long service life. Cutoff limit control provides positive protection in case of excessive temperatures. Factory assembled with controls installed and wired. Single Point Power Kits Control Box used with optional electric heat when single power supply is connected to multi-circuit electric heat. CONTROLS Electronic blower control. Single pole contactor. Trade available components. Defrost Control Defrost control furnished as standard equipment. Gives a defrost cycle for every 0, 60 or 90 minutes (adjustable) of compressor on time at outdoor coil temperatures below freezing. Units are quiet-shift enabled. The compressor is de-energized entering and exiting the defrost cycle, reducing system sounds. Sensor mounted on liquid line determines when defrost cycle is required and also when to terminate cycle. Anti-short cycle, timed-off control incorporated into the board. 4 Volt Transformer 40VA transformer furnished and factory installed in control area. LRP4HP - to 5 Ton Heat Pump / Page 4

FEATURES CONTROLS (continued) Optional Accessories icomfort Equipment Interface Module (EIM) Allows the icomfort Thermostat to be used with residential packaged units. Contains all necessary relays and controls to operate the system and communicate with the icomfort Thermostat. NOTE - The icomfort Equipment Interface Module is required for proper operation of icomfort Thermostats with residential packaged units. icomfort S0 Thermostat The icomfort S0 Thermostat recognizes and connects conventional heating/cooling products to automatically configure and control the system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Also displays service alerts and reminders. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. One-Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away. Weather-On-Demand - Live up-to-date weather data and five-day forecasts. Easy to read 7 in. high definition color display (measured diagonally). High Definition Color Display, Mag-Mount, Smart Hub Controller, wallplate (for retrofit installations) furnished for easy installation. See the icomfort S0 Thermostat Product Specifications bulletin in the Controls section for more information. icomfort Wi-Fi Thermostat The icomfort Wi-Fi Thermostat recognizes and connects conventional heating/cooling products to automatically configure and control the system (based on user-specified settings) for the highest level of comfort, performance and efficiency. Wi-Fi remote temperature monitoring and adjustment through a home wireless network for desktop PCs, laptops and apps for smartphones or tablets. Also displays service alerts and reminders. A simple easy-to-use touchscreen allows complete system configuration. Scheduled maintenance alerts, system warnings and troubleshooting are also displayed on thermostat screen. One-Touch Away Mode - A quick and easy way to set the cooling and heating setpoints while away. Weather-On-Demand - Live up-to-date weather data and five-day forecasts. Easy to read 7-inch color screen (measured diagonally). See the icomfort Wi-Fi Thermostat Product Specifications bulletin in the Controls section for more information. ComfortSense 7500 Touchscreen Thermostat Electronic 7-day, universal, multi-stage, programmable, touchscreen thermostat. 4 Heat/ Cool. Auto-changeover. Dual-fuel control with optional outdoor sensor. Controls dehumidification during cooling mode and humidification during heating mode. Offers enhanced capabilities including humidification / dehumidification / dewpoint measurement and control, Humiditrol control, and equipment maintenance reminders. Easy-to-use, menu driven thermostat with a back-lit, LCD touchscreen. See the ComfortSense 7500 Product Specifications bulletin in the Controls section for more information. Remote Outdoor Temperature Senor for ComfortSense 7500 Thermostat Allows the thermostat to display outdoor temperature. Required in Humiditrol applications. Thermostat See Thermostat bulletins in Controls section and Lennox Price Book for a complete list of thermostats. LRP4HP - to 5 Ton Heat Pump / Page 5

SPECIFICATIONS General Data Model No. LRP4HP4 LRP4HP0 LRP4HP6 LRP4HP4 LRP4HP48 LRP4HP60 Nominal Tonnage.5.5 4 5 Cooling / Heating Performance Cooling Total capacity - Btuh,600 8,600 4,000 40,000 46,000 57,000 Total unit watts 055 600 090 65 480 580 SEER (Btuh/Watt) 4.00 4.00 4.00 4.00 4.00 4.00 EER (Btuh/Watt).00.00.00.00.00.00 High Temp. Heat Total capacity - Btuh,000 7,000,400 9,000 45,000 56,000 Total unit watts 700 40 645 75 565 4440 COP.80.70.70.60.70.70 HSPF Region IV / Region V 8.00 / 6.95 8.00 / 6.95 8.00 / 6.95 8.00 / 6.95 8.00 / 6.95 8.00 / 6.95 Low Temp. Heat Total capacity - Btuh,00 5,900 0,000,600 7,000,600 Total unit watts 570 05 550 00 445 405 COP.0.0.0.0.0.40 Sound Rating Number (db) 78 78 78 78 78 78 Refrigerant Type R-40A R-40A R-40A R-40A R-40A R-40A Charge 5 lbs. oz. 6 lbs. 0 oz. 5 lbs. oz. 0 lbs. 5 oz. 0 lbs. oz. 0 lbs. oz. Condensate drain size (fpt) - in. /4 /4 /4 /4 /4 /4 Outdoor Coil Net Face Area - sq. ft. 6.4 6.4 6.4 6.6 6.6 8.6 Tube diameter - in. 5/6 5/6 5/6 5/6 5/6 5/6 Number of Rows Fins per in. Outdoor Coil Fan Motor horsepower /6 /6 /6 /4 /4 /4 Diameter - in. 4 4 4 Number of blades 4 4 4 Indoor Coil Net Face Area - sq. ft. 4.4 4.4 4.4 6.8 6.8 6.8 Tube Diameter - in. 5/6 /8 /8 /8 /8 /8 Number of Rows Fins per Inch 5 5 5 5 5 5 Indoor Blower Blower wheel size dia. x width - in. 0 x 6 0 x 6 0 x 8 0 x 0 0 x 0 x 9 Motor horsepower /4 /4 / / / Net weight of basic unit - lbs. 4 5 455 460 48 Shipping weight of basic unit ( Pkg.) - lbs. 96 405 45 58 5 555 Electrical characteristics (60 hz) 08/0V-ph-60hz AHRI Certified to AHRI Standard 0/40: Cooling Ratings - 95 F outdoor air temperature and 80 F db/67 F wb entering indoor coil air. High Temperature Heating Ratings - 47 F db/4 F wb outdoor air temperature and 70 F entering indoor coil air. Low Temperature Heating Ratings - 7 F db/5 F wb outdoor air temperature and 70 F entering indoor coil air. Sound Rating Number rated in accordance with test conditions included in AHRI Standard 70. LRP4HP - to 5 Ton Heat Pump / Page 6

OPTIONAL ACCESSORIES - ORDER SEPARATELY Model No. LRP4HP4 LRP4HP0 LRP4HP6 LRP4HP4 LRP4HP48 LRP4HP60 Compressor Crankcase Heater X7 Compressor Hard Start Kit 0J4 Downflow Conversion Kit (includes drain pan overflow switch) 88M9 U80 U8 Electric Heat Size - 08/40V-ph 5 kw - PHK05BP 0W47 7.5 kw - PHK07BP 0W48 0 kw - PHK0BP 0W49 5 kw - PHK5BP 0W50 0 kw - PHK0BP 0W5 Internal Filter Rack Kit (filters not furnished) () 0 x 0 + () 4 X 0 U7 () 0 x 0 U74 Lifting Brackets U76 Clip Curbs 8 in. Height 4W7 4W7 4 in. Height 4V68 4V69 Adjustable Pitch Roof Curb Y7975 Y7976 Single Point Power Kits For 5 kw Electric Heat ASPWR8-0 For 7.5 kw Electric Heat ASPWR84-0 For 0 kw Electric Heat ASPWR85-0 For 5-0 kw Electric Heat ASPWR86-0 W88 W89 W90 W9 CONTROLS - ORDER SEPARATELY icomfort S0 Thermostat U67 icomfort Wi-Fi Thermostat 0F8 Equipment Interface Module (EIM) - 0T50 Required with icomfort thermostat ComfortSense 7500 Thermostat H4 Outdoor Air Temperature Sensor X658 Discharge Air Temperature Sensor 88K8 Filters are not furnished and must be field provided. Remote Outdoor Temperature Sensor is recommended for heat pump balance point control and to lock out some of the the electric heating elements where two-stage control is applicable. Also allows the thermostat to display outdoor temperature. Used with the icomfort S0 and icomfort Wi-Fi Thermostats for optional service diagnostics. LRP4HP - to 5 Ton Heat Pump / Page 7

ELECTRIC HEAT CAPACITIES Input Voltage No of Steps 5 kw 7.5 kw 0 kw 5 kw 0 kw kw KBtuh No of Input Output Steps kw Input KBtuh No of Output Steps kw KBtuh Input Output No of kw KBtuh Steps Input Output No of kw Steps Input KBtuh Output 08.8.8 5.6 9. 7.5 5.6. 8. 5 5. 0 4. 4. 6..5 8.4 8.7.6 4 6.8 57. 0 4.6 5.7 6.9.5 9...8 47 8.4 6.7 40 5 7. 7.5 5.6 0 4. 5 5. 0 68. ELECTRICAL/ELECTRIC HEAT DATA Model No. LRP4HP4 LRP4HP0 LRP4HP6 Line voltage data - 60hz - phase 08/0V 08/0V 08/0V Compressor Rated Load Amps 0.9.5 5.4 Outdoor Fan Motor Locked Rotor Amps 59. 7.5 8.9 Full Load Amps.0.0.0 Locked Rotor Amps.9.9.9 Indoor Blower Motor Maximum Overcurrent Protection Maximum Overcurrent Protection with Optional Single Point Power Supply Minimum Circuit Ampacity Full Load Amps.8.8 4. Locked Rotor Amps.9.9 4.4 Voltage 08V 40V 08V 40V 08V 40V Unit Only Circuit 5 5 0 0 5 5 5 kw Circuit 0 0 0 0 0 5 7.5 kw Circuit 40 45 40 45 40 45 0 kw Circuit 50 60 50 60 50 60 5 kw Circuit - - - - - - 50 60 50 60 Circuit - - - - - - 5 0 5 0 5 kw 45 45 45 50 50 50 7.5 kw 60 60 60 60 60 70 0 kw 70 70 70 80 70 80 5 kw - - - - - - 90 00 00 0 Unit Only Circuit 7.4 7.4 0.7 0.7 4.4 4.4 5 kw Circuit 5.4 8.8 5.4 8.8 6.7 0. 7.5 kw Circuit 6.7 4.9 6.7 4.9 8 4. 0 kw Circuit 47.9 54.9 47.9 54.9 49. 56. 5 kw Circuit - - - - - - 47.9 54.9 49. 56. Minimum Circuit Ampacity with Optional Single Point Power Supply NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. NOTE - Circuit Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. NOTE- Extremes of operating range are plus and minus 0% of line voltage. HACR type breaker or fuse. Circuit - - - - - -.6 6.6 6 5 kw 9. 4.4 4. 45.7 46 49.4 7.5 kw 50. 55.6 5.6 58.8 57. 6.5 0 kw 6.6 68.6 64.8 7.8 68.5 75.5 Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. A separate compressor circuit is required. 5 kw - - - - - - 87.4 97.8 9. 0.5 LRP4HP - to 5 Ton Heat Pump / Page 8

ELECTRICAL/ELECTRIC HEAT DATA Model No. LRP4HP4 LRP4HP48 LRP4HP60 Line voltage data - 60hz - phase 08/0V 08/0V 08/0V Compressor Rated Load Amps 5.9 8 4. Outdoor Fan Motor Indoor Blower Motor Maximum Overcurrent Protection Locked Rotor Amps 85 7 44. Full Load Amps.7.7.7 Locked Rotor Amps... Full Load Amps.8.8 7.6 Locked Rotor Amps 5..4 6.8 - - - Voltage 08V 40V 08V 40V 08V 40V Unit Only Circuit 40 40 45 45 60 60 5 kw Circuit 0 0 0 0 5 5 7.5 kw Circuit 40 45 40 45 45 50 0 kw Circuit 50 60 50 60 60 60 5 kw Circuit 50 60 50 60 60 60 Circuit 5 0 5 0 5 0 0 kw Circuit 50 60 50 60 60 60 Circuit 50 60 50 60 50 60 Maximum Overcurrent Protection with Optional Single Point Power Supply Minimum Circuit Ampacity 5 kw 50 50 60 60 80 80 7.5 kw 60 70 70 70 80 90 0 kw 70 80 80 80 90 00 5 kw 00 0 00 0 0 5 0 kw 5 50 5 50 50 50 Unit Only Circuit 4.4 4.4 7.0 7.0 9.7 9.7 5 kw Circuit 5.4 8.8 5.4 8.8 0..6 7.5 kw Circuit 6.7 4.9 6.7 4.9 4.5 46.7 0 kw Circuit 47.9 54.9 47.9 54.9 5.7 59.7 5 kw Circuit 47.9 54.9 47.9 54.9 5.7 59.7 Minimum Circuit Ampacity with Optional Single Point Power Supply Circuit.6 6.6 6.6 6 0 kw Circuit 47.9 54.9 47.9 54.9 5.7 59.7 NOTE - All units have a minimum Short Circuit Current Rating (SCCR) of 5000 amps. NOTE - Circuit Minimum Circuit Ampacity includes the Blower Motor Full Load Amps. NOTE- Extremes of operating range are plus and minus 0% of line voltage. HACR type breaker or fuse. Circuit 45. 5. 45. 5. 45. 5. 5 kw 45. 48.7 47.9 5. 60.6 64 7.5 kw 56.6 6.8 59. 64.4 7.9 77. 0 kw 67.8 74.8 70.4 77.4 8. 90. 5 kw 90.4 00.8 9. 0.4 05.7 6. 0 kw.9 6.8 5.6 9.4 8. 4. Refer to National or Canadian Electrical Code manual to determine wire, fuse and disconnect size requirements. A separate compressor circuit is required. FIELD WIRING THERMOSTAT (Optional) A B SINGLE PACKAGE UNIT DISCONNECT SWITCH (Not Furnished By Lennox) A Five Wire Low Voltage (Electronic) B Two Wire Power (See Electrical Data Table) If multiple disconnects are used on units with electric heat; there must be two wire power provided for each disconnect Field Wiring Not Furnished LRP4HP - to 5 Ton Heat Pump / Page 9

BLOWER DATA LRP4HP4 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume at Specific Blower Taps (cfm) Tap Tap Tap Tap 4 (Low Static Electric Heat) Tap 5 (High Static Electric Heat) 0.0 680 890 000 890 - - - 0.0 590 80 960 80 - - - 0.0 550 800 90 800 - - - 0.40 500 760 880 760 - - - 0.50 450 70 840 - - - 840 0.60 80 680 80 - - - 80 0.70 - - - 640 770 - - - 770 0.80 - - - 600 70 - - - 70 NOTE - All air data measured external to unit with dry coil and less filter. Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection. LRP4HP0 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume at Specific Blower Taps (cfm) Tap Tap Tap Tap 4 (Low Static Electric Heat) Tap 5 (High Static Electric Heat) 0.0 680 00 80 00 - - - 0.0 640 070 60 070 - - - 0.0 600 050 0 050 - - - 0.40 570 00 090 00 - - - 0.50 50 990 070 - - - 070 0.60 490 960 040 - - - 040 0.70 - - - 90 00 - - - 00 0.80 - - - 900 960 - - - 960 NOTE - All air data measured external to unit with dry coil and less filter. Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection. LRP4HP6 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume at Specific Blower Taps (cfm) Tap Tap Tap Tap 4 (Low Static Electric Heat) Tap 5 (High Static Electric Heat) 0.0 900 0 50 0 - - - 0.0 860 80 490 80 - - - 0.0 80 50 460 50 - - - 0.40 770 0 40 0 - - - 0.50 70 00 80 - - - 80 0.60 680 80 40 - - - 40 0.70 60 0 50 - - - 50 0.80 560 00 70 - - - 70 NOTE - All air data measured external to unit with dry coil and less filter. Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection. LRP4HP - to 5 Ton Heat Pump / Page 0

BLOWER DATA LRP4HP4 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume at Specific Blower Taps (cfm) Tap Tap Tap 4 0.0 790 500 070 0.0 740 470 050 0.0 670 40 00 0.40 590 70 980 0.50 50 0 90 0.60 40 40 870 0.70 0 40 80 0.80 0 00 690 NOTE - All air data measured external to unit with dry coil and less filter. LRP4HP48 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume at Specific Blower Taps (cfm) Tap Tap Tap 4 0.0 970 70 50 0.0 890 690 480 0.0 790 600 40 0.40 690 540 70 0.50 600 450 0 0.60 50 60 0 0.70 400 70 40 0.80 80 50 050 NOTE - All air data measured external to unit with dry coil and less filter. LRP4HP60 BLOWER PERFORMANCE External Static Pressure in. w.g. Air Volume at Specific Blower Taps (cfm) Tap Tap Tap Tap 4 (Low Static Electric Heat) Tap 5 (High Static Electric Heat) 0.0 400 90 40 90 - - - 0.0 0 870 00 870 - - - 0.0 60 80 40 80 - - - 0.40 00 770 00 770 - - - 0.50 0 70 060 - - - 060 0.60 060 670 00 - - - 00 0.70 980 450 980 - - - 980 0.80 900 60 950 - - - 950 NOTE - All air data measured external to unit with dry coil and less filter. Taps 4 and 5 are used with Optional Electric Heat. Refer to Electric Heat nameplate for proper heat tap selection. LRP4HP - to 5 Ton Heat Pump / Page

COOLING RATINGS Model Indoor Temp DB/WB ºF Outdoor Temperature - DB 65 F 8 F 95 F 05 F 5 F Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw Btuh S/T kw 85/7 9,500 0.6.40 8,00 0.65.67 7,000 0.67.89 5,400 0.7.06,800 0.78. LRP4HP4 80/67 7,800 0.70.9 6,00 0.7.65 4,800 0.74.89,00 0.80.07,800 0.86.4 75/6 6,400 0.7.8 4,400 0.76.66,800 0.79.87,500 0.84.06 0,00 0.88.5 75/57,00.00.8,800.00.65 0,600.00.86 0,00.00.05 9,500.00.5 85/7 9,700 0.66.9,00 0.69.7,600 0.7.5 9,600 0.74.7 6,600 0.76.89 LRP4HP0 80/67,500 0.7.89,700 0.74.8 0,00 0.76.48 7,900 0.80.69 5,600 0.84.90 75/6,700 0.75.85 9,00 0.79. 7,400 0.8.49 5,600 0.84.69,800 0.86.89 75/57 9,900.00.87 7,500.00.4 5,800.00.5 4,500.00.7,00.00.89 85/7 46,00 0.6.5 4,900 0.6.79 4,000 0.65. 7,900 0.7.40,800 0.8.68 LRP4HP6 80/67 4,800 0.67. 4,000 0.7.7 7,00 0.74.0 4,000 0.8.8 0,900 0.88.66 75/6 4,600 0.70. 7,900 0.7.7 5,00 0.76.06,000 0.8.6 8,900 0.90.66 75/57 4,500.00.0,600.00.7 9,00.00.05 8,700.00.5 8,00.00.65 85/7 5,00 0.64.58 49,000 0.67.04 45,700 0.70.9 4,00 0.75.7 8,500 0.80 4.04 LRP4HP4 80/67 49,800 0.7.56 44,800 0.75.98 40,700 0.77.8 8,000 0.8.7 5,00 0.88 4.05 75/6 45,700 0.76.56 4,000 0.79.0 7,400 0.8.9 5,00 0.86.7,900 0.9 4.06 75/57 4,00.00.55 7,800.00.0 5,00.00.8,500.00.7,900.00 4.06 85/7 67,000 0.6.95 60,500 0.64.48 55,600 0.66.89 50,00 0.7 4.9 44,600 0.76 4.89 LRP4HP48 80/67 60,400 0.68.94 5,700 0.7.44 48,400 0.74.9 44,700 0.78 4.40 4,00 0.8 4.87 75/6 55,00 0.7.9 49,00 0.74.47 44,600 0.76.89 4,000 0.8 4.8 9,00 0.88 4.87 75/57 47,00.00.9 4,00.00.44 40,00.00.84 9,000.00 4.5 8,000.00 4.86 85/7 74,00 0.6.54 68,00 0.65 4. 6,500 0.67 4.9 60,00 0.7 5.5 56,600 0.75 6.4 LRP4HP60 80/67 69,00 0.69.5 6,000 0.7 4.4 57,700 0.7 4.85 55,000 0.78 5.48 5,400 0.8 6.0 75/6 64,00 0.7.49 57,00 0.74 4.9 5,700 0.76 4.7 50,400 0.80 5.9 49,000 0.84 6.07 75/57 57,500.00.44 5,700.00 4. 47,00.00 4.80 46,900.00 5.4 46,500.00 6.04 HEATING RATINGS Outdoor Temp - DB/WB ºF Model 0/0 7/5 5/ 47/4 6/56 Btuh kw Btuh kw Btuh kw Btuh kw Btuh kw LRP4HP4 7,000.55,00.60 7,900.68,000 70 7,800.75 LRP4HP0 9,900.9 5,900.00,00.0 7,00 60,000. LRP4HP6,500.49 0,00.50 4,00.59 4,00 70 40,500.80 LRP4HP4 4,800.99,600.0,000.9 40,000.6 48,700.45 LRP4HP48 8,700.6 7,000.40 5,800.77 46,400.9 57,700 4.05 LRP4HP60 0,00.89,700 4.0 48,00 4.5 57,000 4.78 67,400 4.88 LRP4HP - to 5 Ton Heat Pump / Page

DIMENSIONS - UNIT - INCHES (MM) (5) 46-/4 (87) -/ (9) DOWNFLOW SUPPLY AIR OPENING DOWNFLOW RETURN AIR OPENING -/4 (8) F E (5) B TOP VIEW HORIZONTAL SUPPLY AIR OPENING 4-/4 (6) HORIZONTAL RETURN AIR OPENING 7 (4) A G -/4 (8) H -/8 (79) -/ (89) 8-/8 (06) POWER ENTRY -/8 (9) DIA. KNOCKOUT LOW VOLTAGE ENTRY 7/8 () DIA. KNOCKOUT ELECTRIC HEAT POWER ENTRY CONDENSATE DRAIN /4 NPT 8-/8 (460) -/4 (70) C D C -/4 (57) BACK VIEW RIGHT SIDE VIEW -/4 (4) Model No. A B C D E in. mm in. mm in. mm in. mm in. mm LRP4HP4, 0, 6 6-7/8 97 46-/4 87 -/8 40 5-7/8 49 6-/4 45 LRP4HP4, 48, 60 40-7/8 08 55-/4 40 8-/8 467 4-5/8 7 9-/4 50 Model No. F G H in. mm in. mm in. mm LRP4HP4, 0, 6 4 56 8-/8 74 -/8 56 LRP4HP4, 48, 60 9-/ 495 -/8 86 6-/8 664 LRP4HP - to 5 Ton Heat Pump / Page

DIMENSIONS - ACCESSORIES - INCHES (MM) CLIP CURB 44-5/8 () 0 (54) C (88) Unit Mounting Brackets (4) B A SUPPLY OPENING F -7/8 (48) G Insulated Pan Unit Mounting Brackets (4) 8 (0) 4 (56) 8 (0) E RETURN OPENING -/8 (79) -5/8 (95) (88) 4 (0) 44 (8) D TYPICAL FLASHING DETAIL WOOD NAILER CURB FRAME COUNTER FLASHING (FIELD SUP PLIED) NOTE - Roof deck may be ommitted within confines of curb. ROOFING FELT (FIELD SUP PLIED) RIGID IN SU LA TION (FIELD SUP PLIED) CANT STRIP (FIELD SUP PLIED) Usage A B C D E in. mm in. mm in. mm in. mm in. mm 4, 0, 6 44-5/8 4 09 8 457 44 8 7 940 4, 48, 60 5-/8 49 5 95 4 60 5-/ 4 4 04 Usage F G in. mm in. mm 4, 0, 6 4 56 6-/4 45 4, 48, 60 9-/ 495 9-/4 50 LRP4HP - to 5 Ton Heat Pump / Page 4

DIMENSIONS - ACCESSORIES - INCHES (MM) ADJUSTABLE PITCH ROOF CURB FRONT FLANGE 8 in. (0 mm) MINIMUM HEIGHT 4 in. (0 mm) DECK PAN UNIT HOLD DOWN BRACKET (4) C B A (5) TYP ADJUSTABLE FROM / to 6/ PITCH SIDES AND BACK FLANGE 6 in. (5 mm) D E F 46-/ (8) (05) 7 (4) SUPPLY OPENING RETURN OPENING 4 (0) G Usage A B C D in. mm in. mm in. mm in. mm 4, 0, 6 47 94 4-/ 876 5 7 -/4 857 4, 48, 60 55-/4 40 4-/8 076 0 54 88 Model No. E F G in. mm in. mm in. mm 4, 0, 6 4-/ 68 8-/4 476 8 457 4, 48, 60 0 508 -/8 57 8-/4 464 INSTALLATION CLEARANCES in. mm Front (heat exchanger access) 4 60 Right Side (blower access) 4 60 Left Side (evaporator coil access) 4 60 Back 0 0 Top 48 9 LRP4HP - to 5 Ton Heat Pump / Page 5

REVISIONS Sections Dimensions - Accessories Description of Change Updated opening dimensions. Added Adjustable Pitch Roof Curb. Visit us at www.lennox.com For the latest technical information, www.lennoxdavenet.com Contact us at -800-4-LENNOX NOTE - Due to Lennox ongoing commitment to quality, Specifications, Ratings and Dimensions subject to change without notice and without incurring liability. Improper installation, adjustment, alteration, service or maintenance can cause property damage or personal injury. Installation and service must be performed by a qualified installer and servicing agency. 06 Lennox Industries, Inc.