Engineered for flexibility and performance

Similar documents
Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Engineered for flexibility and performance

Engineered for flexibility and performance

Applied Packaged Terminal Air Conditioner and Heat Pumps

Applied Packaged Terminal Air Conditioner and Heat Pumps

Catalog Applied Packaged Terminal Air Conditioner with Top-mounted Hydronic Heat

Applied Packaged Terminal Air Conditioner with Catalog Top-Mounted Hydronic Heat

Incremental Comfort Conditioners

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

Applied Packaged Terminal Air Conditioner

Catalog 1304 Packaged Terminal Air Conditioner with Top-Mounted Hydronic Heat Model PGAN - Unit Sizes

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

Applied Packaged Terminal Air Conditioner and Heat Pump

Applied Packaged Terminal Air Conditioner

Specifications and Performance

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS. New Construction Model. Model EGN Superior Sound Performance. High Efficiency

PACKAGED TERMINAL AIR CONDITIONER SOLUTIONS

McQuay. Incremental Packaged Terminal Air Conditioner. MQT Vintage B. Last Manufactured: 1994

Catalog Daikin Type K. Incremental Room Conditioner. Engineered for flexibility and performance

McQuay Type J Series Incremental Conditioner

Specifications and Performance

MACH N-407 Heat Pump Air-Cooled Chiller

ICE AIR LLC. Draw1 REV. - PERFORMANCE DATA 117/133 COOLING CAPACITY CORRECTION FACTORS HEATING CAPACITY CORRECTION FACTORS

McQuay Climate Control Singer. Incremental. ES, RS, S 06, 09, 11, 14 Vintage B. Last Manufactured: 1991

SPXB-HW Series Single Package Vertical Unit Cooling with Hot Water Heat 1 through 2 tons, up to 47,800 BTUH Heating

MAC N-407 Air-Cooled Chiller

McQuay. Incremental. MQS Vintages A Vintage B. Last Manufactured: Replacement Parts List No Revision E 08/2017

Series PIN. New Construction or Renovation. Application Flexible Quiet Comfort Damage Protection

EnerSaver Packaged Terminal Air Conditioner Catalog 1303 and Heat Pump with R-410A Refrigerant

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

Daikin McQuay. EnerSaver Packaged Terminal Air Conditioner/Heat Pump. PNES; PNHS Design D (4)

Applied Packaged Terminal Air Conditioner

PTAC 2017 Air Conditioner Collection

Packaged Terminal Air Conditioner (PTAC)

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

Packaged Terminal Air Conditioner (PTAC)

Packaged Terminal Air Conditioner (PTAC)

NEW 2011 DESIGN AIR CONDITIONERS

Packaged Terminal Air Conditioner (PTAC)

RetroAire Model Number: 9,000 to 36,000 Btuh (2.6 to 10.5 kw)

General Description. Operation

Product Specifications. Vertical Floor Consoles By First Co.

Series PIC. New Construction and Renovation; Replaces RetroAire VPAC and First Company DPU Application Flexible Quiet Comfort Damage Protection

SPXA / SPXA-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

SPXB / SPXB-HP Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

CAS. Product Specifications. COMMERCIAL SPLIT SYSTEMS CONDENSING UNITS R 410A, 6 to 12.5 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

MHCCW Chilled Water Ceiling Concealed With 5kW Electric Heat 2-Pipe Heat / Cool Fan Coil 30,000 BTUH

McQuay/Remington. Installation & Maintenance Data IM Packaged Terminal Air Conditioners and Heat Pumps C Vintage.

FRIGIDAIRE PTAC COLLECTION AIR CONDITIONERS

MHCCW Chilled Water Ceiling Concealed Without Electric Heat 2-Pipe Heat / Cool Fan Coil 18,000 BTUH

McQuay. Incremental. MQE 007, 009, 012, 015, 016 MQR 007, 009, 012, 015 Vintage D. Last Manufactured: 2000

McQuay. Incremental. PSEA, PSEC, PSEH, PSEI, PSES, PSHA, PSHC, PSHI, PSHS Suite II, 1 Motor 007, 009, 012, 015 Design A (1)

15 SEER SINGLE- PACKAGED HEAT PUMP SYSTEM WITH PURON

Parts Diagram. Up button. Down button. Right (fan) button. Left (system) button. RC/RH Jumper. Field programming pins

Packaged Terminal Air Conditioners. SG Series. Efficient and reliable for the lowest cost of ownership. More efficient. More reliable.

MHWW-24-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 24,000 BTUH

MHWW-09-H-1 Chilled/Hot Water Hi-Wall Fan Coil 2-Pipe Heat / Cool Fan Coil 9,000 BTUH

Stanford University Facilities Design Guidelines SECTION DECENTRALIZED UNITARY HVAC EQUIPMENT

PACKAGED TERMINAL AIR CONDITIONERS

E Z S E R I E S " W X 16" H

Scholar III Unit Ventilator

Packaged Terminal Air Conditioners & Heat Pumps

Advance Product Data. Features/Benefits. 42WKN Hydronic Fan Coil Units

1 to 5 Ton Vertical Wall Mount Air Conditioners Models AVPA

Catalog EnerSaver Packaged Terminal Air Conditioners and Heat Pumps

R11C R12C R21C R22C/H R23C/H R24C/H

SPXR-A / SPXR-HP-A Series Single Package Vertical Unit Straight Cool and Heat Pump 3/4 through 2 tons, up to 10 kw Electric Heat

NEW! Digital Packaged Terminal Air Conditioners. Over 40 standard features! Distinct, audible sound improvements

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

PTAC/PTHP. Packaged Terminal Air Conditioners and Heat Pumps. Residential & Light Commercial HVAC. Features: Performance:

Vert-I-Pak Series. Single Package Vertical Air Conditioners. Installs easily in a closet for quiet operation THE EXPERTS IN ROOM AIR CONDITIONING

Q-TEC QC-Series Chilled Water Air Conditioner

9 EER 1-5 Ton Vertical Packaged Wall Mount Air Conditioners

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

CATALOG. SKYPAK Self-Contained Heating/Cooling Units

Single Package Vertical Air Conditioners. Vert-I-Pak

WLCG/WLHG. Specifications and Performance WLCG/WLHG. (with EMI AmericaSeries condensers)

Daikin McQuay. Packaged Terminal Air Conditioner. PGAN 007, 009, 012, 015 Design 1. Replacement Parts List No Revision D 02/2015

CRSO SERIES CEAFO SERIES

SeasonMaker ThinLine Fan-coil Units

SeasonMaker ThinLine Fan-coil Units

Q-Tec TM QC-Series Chilled Water Air Conditioner

50TM COMBINATION HEATING/COOLING UNITS

SpaceKeeper Console (SKC)

CHS. Product Specifications COMMERCIAL SPLIT SYSTEMS HEAT PUMP UNITS R 410A, 6 10 TONS BUILT TO LAST, EASY TO INSTALL AND SERVICE

Zoneline vertical packaged terminal air conditioners

MHNCCW (4-Pipe) Chilled/Hot Water Ceiling Concealed 208/230V 4-Pipe Heating & Cooling Fan Coil 12,000 BTUH

VERT-I-PAK SERIES SINGLE PACKAGE VERTICAL AIR CONDITIONERS

FCC Fan-Coil Units High-Performance, Vertical

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

PTAC Air Conditioners 11.7 EER / 3.4 COP. and Heat Pumps

MAC-120HE-03 Air-Cooled Chiller

Specifications and Performance

VariCool VAV Engineering Guide

CFFWA4P-08-1-U Chilled/Hot Water Universal Mount Fan Coil (4-Pipe) 4-Pipe Heat / Cool Fan Coil 24,000 BTUH

Concealed Ducted Split Series R-407C MBH

SG SERIES PTACs THE EXPERTS IN ROOM AIR CONDITIONING

Shelf Units R-407C. 2, 3, and 4 ton. ISO 9001 Certified

Product Data. Fig. 1 - Unit 50VR -A

Product Data. Features/Benefits. 40QKB024,036 40QKE024,036,048 Cooling Only and Heat Pump In-Ceiling Cassettes. 2to4NominalTons

Transcription:

Catalog 1301-5 Applied Packaged Terminal Air Conditioner 16" 44" Flat Top Replacement Unit Model PDAE Unit Sizes 007 017 R-410A Refrigerant Engineered for flexibility and performance

Contents Nomenclature... 3 Beyond Standard Expectations... 4 Evolution of the 16" 44" Packaged Terminal Air Conditioners and Heat Pumps:... 4 Superior zoned heating and cooling:... 4 Daikin Applied PTAC is the right choice!... 4 The Hydronic Experts... 4 Features and Benefits & Options... 5 Room Comfort... 5 Dehumidification:... 5 Constant Room Temperature Monitoring... 5 Intelligent Outdoor Air Damper Control... 5 Indoor Air Quality Options... 5 Reliability and Durable Construction... 5 Positive Condensate Removal... 5 Room Freeze Protection... 6 Compressor Protection... 6 Memory Recall... 6 Fresh Air Power Vent (Option)... 6 Merv 11 Filter (Option)... 6 Easy Installation and Service Design... 6 Quick Link Connections... 6 Easy To Read LED Diagnostics... 6 Controls-With Built In Hydronic Logic... 6 16" x 44" Replacement Unit Features... 7 PDAE 16" 44" Flat Top Replacement Unit... 7 Quiet Running... 8 Digital Touchpad Control... 9 Standard (Non-Programmable) Digital Touchpad... 9 Premium (7-Day Programmable)Digital Touchpad.10 Master-Slave Control (Optional)... 10 Cool/Dry Mode:... 10 Digital Touchpad with Automatic Changeover from Cooling to Heating & Heating to Cooling... 10 AUTO Non-Programmable Mode:... 10 AUTO Programmable Mode:... 10 Wireless Remote Control (optional)... 11 PDAE Chassis Customization Options... 12 Other Customization Options 16 x 42 Units... 12 Model PDAF Flat Top 16 x 42... 12 AHRI Performance Data... 13 Dimensional Data... 14 PDAE Air Conditioner with Electric Heat... 14 Typical Installation... 15 Accessories Quick Selection Guide... 16 Remote Thermostat Control... 16 Accessories... 17 Wall-Mounted, Non-Programmable Thermostat... 17 Manual Changeover One-Stage Heat and Cool or One-Stage Heat Pump... 17 Wall-Mounted, 7, 5-2 & 5-1-1 Programmable Thermostat... 17 Manual Changeover One-Stage Heat and Cool or One-Stage Heat Pump... 17 Programmable - Standard Auto or Manual- Changeover Two-Stage Heat/Two Stage Cool...18 Optional Remote Sensor... 18 Wireless Temperature Control (T9000)... 18 Remote Control Node (RCN)... 18 Electrical Subbase 3" or 4" High... 19 Hydronic Subbase 8" High Heat Section... 20 Drain Kits... 21 Wall Sleeve Extension... 22 PDAE 16" 44" Replacement Unit... 22 Louver Frame... 22 Louver... 23 ExtendAire Kit... 24 Typical ExtendAire Configurations... 24 Wiring Diagrams... 25 Premium (Programmable) Digital Control... 25 2 Jumper Placement to Select Fan Control:... 25 Standard (Non-Programmable) Digital Control... 26 Digital Control Board with Standby Power... 27 Digital Control Board Without Standby Power... 28 Engineering Guide Specifications PDAE 16" x 44"... 29 Page 2 of 32 Catalog 1301-5

Nomenclature Note: For Illustration purposes only. Not all options available with all models. Please consult a Daikin Sales Representative for specific availability. Unit Type P = PTAC Product Identifier PDAE - Replacement Air Conditioner P DAE 2 009 E D A H A B D M A A E Warranty A = Standard E = Extended X =Special Design Series 1 = A Design 1 2 = B Design 2 3 = C Design 3 4 = D Design 4 5 = E Design 5 Unit Size 007 = 7,000 009 = 9,000 012 = 12,000 015 = 15,000 017 = 17,000 (Cooling Only) Voltage A = 115-60-1 E = 208/230-60-1 J = 265/277-60-1 P = 208/230-60-1 w/standby 115-60-1 R = 265-60-1 w/standby 115-60-1 T = 208-60-1 w/standby 208-60-1 Brand Name D = Daikin SKU A = Stock B = Build to Order Upgrade Packages S = Seacoast Y = None Power Connection L = Long Cord 72" (Standard) S - Short Cord 30" (Optional) Y = None Room Interface Cabinet Type D = 16" 44" Replacement Refrigerant A = R-410A Heating Type E = Electric Heat H = Hydronic A = Hydronic w/intermediate Electric Electric Heat A = 2.5 Kw B = 3.5 Kw C = 5.0 Kw Y = None Hydronic Heat Type S = Steam Top Mount (Normally Closed) H = Hot Water Top Mount (Normally Open) Y = None Controls Control Board Type B = Basic Control P = Premium Controls (Req'd for Hydronic Heat) User Interface Type P = Programmable (Unit Mtd. Touchpad) A = Programmable with Auto Changeover (Unit Mtd. Touchpad) N = Non-Programmable (Unit Mtd. Touchpad) Y = None (Wall Stat with Blank-off Plate) Damper Type Damper Control A = Automatic A = Fresh Air Power Vent M = Manual Y = No Damper Catalog 1301-5 Page 3 of 32

Beyond Standard Expectations Evolution of the 16" 44" Packaged Terminal Air Conditioners and Heat Pumps: In 1970, McQuay designed and introduced the first Packaged Terminal Air Conditioner (PTAC) system with an integrated heating and cooling chassis. The 16 44 type EA series became a best seller with over 350,000 units sold worldwide. In 1976 McQuay introduced the first air-to-air packaged terminal heat pump (PTHP) with the 16 44 type RS unit. The RS offered unprecedented energy savings in the midst of the energy crisis of that period. In 2008 McQuay is proud to continue our tradition of design excellence with the introduction of our highly efficient and quiet 16 44 Applied PTAC. The Hydronic Experts Daikin is a leading manufacturer of hydronic heat equipment. We specialize in providing hydronic heat with a host of configurable options. Modes Cooling only mode with hydronic heat Cooling only mode with hydronic heat and supplemental electric heat. Subbase hydronic (steam or hot water) Superior zoned heating and cooling: Hotel and motel guest rooms Hospitals and assisted living facilities Apartments, college dormitories and military barracks Offices and other spaces in a variety of buildings Daikin Applied PTAC is the right choice! The broadest selection of features and customizable options allows you to choose the ideal unit for each space in your building. High energy efficiency and COP ratings provide lower operating costs. R-410A refrigerant with no ozone depletion potential or phase-out date. Reliable cooling/heating and low operating sound levels maximize comfort. Proven institutional grade construction withstands demanding applications for long life. Easy to install and maintain. Engineered and produced in the U.S.A. since 1955. Replacement 16" 44" Flat top PDAE (with accessories) Page 4 of 32 Catalog 1301-5

Features and Benefits & Options Room Comfort Easy To Use Digital Controls The unit control pad offers digital readout and is easy to use when selecting fan speed, mode of operation and temperature setting. A precise digital temperature display provides guests with an exact comfort setting, thereby eliminating uncomfortable temperature swings and costly overheating/overcooling associated with non-digital electromechanical controls. Figure 1: Standard Digital Touchpad Control Dehumidification: The cool/dry mode automatically controls humidity by extending the cool cycle without sacrificing comfort for added dehumidification. This mode comes standard with all units with unit-mounted controls. Constant Room Temperature Monitoring Units are designed to automatically sample the room temperature and adjust operation to meet desired temperature set points. Intelligent Outdoor Air Damper Control Note: Available With Premium Control Board Units Only Four modes of damper control improve energy efficiency and control humidity in the conditioned space: Cycle mode opens and closes the damper when the indoor fan is energized. An outdoor temperature override feature closes the outdoor air damper in high or low ambient conditions to reduce energy consumption. The control set up mode allows the damper operate in cycle or closed modes. Indoor Air Quality Options Damper control Outdoor fresh air is brought in through a manual or automatic (optional) damper. Fresh Air Damper Can be added to your auto damper. This will deliver 90 cfm of outdoor air into the space. Cleanable filters Easy to remove, cleanable filters come standard with each unit. Figure 2: Manual Fresh Air Damper Control - Left End Manual outdoor damper Reliability and Durable Construction High-Grade Cabinetry Applied PTAC cabinets are constructed of 18-gauge steel with baked on powder coat paint for maximum durability and aesthetic appeal. Grilles are constructed of impact resistant polycarbonate. Seacoast Construction (Option) Applied PTAC units can be ordered with components treated with special coatings that extend the life of the unit dramatically, helping to protect it from corrosive vapors such as salt water vapor, chlorine, and acid vapor. See "Table 1: Chassis Customization Options" on page 12 for SeaCoast Construction Option details. Positive Condensate Removal Our unique three level sloped basepan design provides positive condensate removal to prevent condensate build-up or overflow, (Figure 3). Figure 3: Three-Level Sloped Basepan Positive condensate removal Condensate is reduced by controlling the humidity within the conditioned space, reducing the amount of condensate generated in conjunction with positive condensate removal features. The three-level base pan efficiently directs condensate from the evaporator drain pan to the outdoor condenser section. Catalog 1301-5 Page 5 of 32

Features and Benefits & Options A slinger ring on the outside radius of the condenser fan pulls condensate into the condenser air stream, evaporating it against the warm condenser coil. Humidity controls and positive condensate removal features together greatly reduce or eliminate excess condensate. In the process, comfort is improved and energy reduced by using the Applied PTAC s advanced digital controls to intelligently manage ventilation air and humidity within the conditioned space. Merv 11 Filter (Option) Pleated MERV 11filters are available to provide an average of at least 85% mold removal. The synthetic media, fibers are hydrophobic in nature and non-supportive of microbial growth. Figure 5: Merv 11 Filter Filter Front Room Freeze Protection When the unit senses temperatures of 40 F or lower in an unoccupied room, the heat mode is automatically initiated to prevent freezing. The outdoor fan and compressor are stopped to help prevent coil freeze. Compressor Protection The life of the compressor is extended through built in protection logic such as: High temperature protection if the compressor temperature exceeds 154 F Minimum run time Minimum off time Random restart after a power outage Low ambient lockout when the outdoor air temperature falls below 35 F Memory Recall Control settings are saved in a non-volatile memory, allowing the last settings to be recalled after a loss of power. Fresh Air Power Vent (Option) The Fresh Air Power Vent option provides additional dilution ventilation, improving indoor air quality by increasing the number of air changes over natural ventilation. This additional controlled ventilation provides 90 cfm of outdoor ventilation air. Filter Back Easy Installation and Service Design Quick Link Connections Applied PTAC units are designed for easy access with quick link connections to the control box. The simple slide in/slide out configuration makes it easy to access the electric heater, indoor and outdoor fans, motors, and compressor. Figure 6: Easy Fan Removal Easy fan motor removal Condenser section Fan & Shroud Figure 4: Fresh Air Power Vent Easy To Read LED Diagnostics Sensors in the unit continually monitor the indoor coil, outdoor coil, and outdoor air conditions. If abnormal conditions are detected, an error code is displayed, removing the guess work in troubleshooting a unit. Controls-With Built In Hydronic Logic Normally open/normally closed valve control Heat fan lockout prevent the fan from coming on until there is heat in the pipes. Page 6 of 32 Catalog 1301-5

16" x 44" Replacement Unit Features PDAE 16" 44" Flat Top Replacement Unit The right choice for your replacement application Direct replacement for: McQuay/Remington/Singer models, PMES, PMRS, PMEG, EA, RS, MQA A. Heating/Cooling chassis Complete air cooled refrigeration system with a low noise tangential fan, outdoor propeller fan with slinger ring provides efficient condensate removal. Fan motors and concealed manual fresh air damper (auto damper for hydronic). The heating system with electric heat consists of low mass, quick response grid type electric heaters with high limit cutout. Hydronic heat has a 24-volt valve signal. Power cord exits from under the right side. B. Evaporator & condenser coil High capacity coils employ the latest in heat transfer technology to provide maximum comfort and energy efficiency. C. Combination room cabinet and wall sleeve Constructed of heavy-gauge, zinc-coated phosphatized steel. Antique Ivory powder paint finish provides maximum corrosion protection. Four-position discharge grilles can be easily arranged to provide the proper distribution of air. Through the wall dimension of only 16-3/8" 44-7/8" D. Front Panel Modern styling and ingenious design have resulted in the exclusive, multi-purpose front panel. Four-way room air return around its periphery. Its design reduces dust collection and provides easy access to filter. E. Louver (accessory) Heavy-duty, architectural, extruded aluminum to resist weathering. F. Digital control module The solid state control module provides heating, cooling and ventilation control logic as well as system diagnostic capability and unit protection. Control features are configurable by jumper placement. G. ExtendAire (Option) The ExtendAire accessory is a lateral duct extension designed to provide balanced heating and cooling in two rooms using a single PDAE unit. When the indoor fan is energized, the optional Boost Fan operates in conjunction to assist airflow into the adjoining room. C E A B D. Front panel Four-way room air return around its periphery, permits flat-on-the-floor installation. D F G Boost Fan (Optional) Catalog 1301-5 Page 7 of 32

16" x 44" Replacement Unit Features Exceptionally Quiet Operation J. Fan Motors Indoor Fan Motor H K J I Outdoor Fan Motor L H. Tangential Indoor Fan The indoor fan evenly circulates air across the evaporator coil and into the occupied space. This fan is constructed of metal and the motor incorporates permanently lubricated bearings for long life and trouble-free service. Quiet Running J. Compressor The reliable, high efficiency rotary compressor is hermetically sealed and designed for continuous operation. The compressor is isolated to minimize vibration and sound transmission for quiet operation. J. Compressor K. High Capacity Heat Transfer Surfaces The finned/tube coils incorporate state-of-the-art technology. The unique design of these coils provides high efficiency and low air pressure drops, in addition to allowing easy cleaning during scheduled maintenance. Sound Comparison Conversational Speech Applied PTAC - Size 012 Cooling Only - Low Speed Applied PTAC - Size 012 Fan Only - Low Speed Typical Library K. Indoor Coil K. Outdoor Coil I. Fan Motors High efficiency, quiet PSC fan motors. All motors are permanently lubricated for extended life. The outdoor fan motor is totally enclosed to help prevent damage from driving rain or excess condensate accumulation in humid climates. L. Filtration Room side return air is filtered through this permanent, washable polypropylene mesh filter. It is UL listed class II, 38% average arrestance efficiency (ASHRAE test), with low resistance to airflow (0.02 w.g. at 300 cfm), and high dust holding capacity (55 grams). Permanent, Washable Polypropylene Mesh Filter (Shown in front return configuration) Page 8 of 32 Catalog 1301-5

16" x 44" Replacement Unit Features Digital Touchpad Control The PDAC/PDHP Standard Touchpad Control is used to control both an integral air conditioner and a source of heat. The user will by default control the electronic controller via the touchpad. The user can select with a jumper for the unit to receive commands from a remote thermostat. Standard (Non-Programmable) Digital Touchpad Provides 5-selectable modes of operation: Sleep, Cool, Cool/Dry, Fan, Heat Temperature can be displayed in Fahrenheit (default) or Celsius Figure 7: Standard (Non-Programmable) Digital Touchpad 9- LED Indicators LED 2-Digit Display 7- Push Buttons Inputs And Outputs Indoor coil sensor, (ICS) Outdoor coil sensor, (OCS) Indoor air sensor, (IAS) Outdoor air sensor, (OAS) Remote thermostat, T STAT (RCBYWG) Power supply: (24VAC) Line voltage input, (L1, L2) Indoor fan standby voltage, (L1STB L2STB) Control selection: (LUI, T STAT Model selection: (AC/E, HP, HP/E) Time delay bypass, (TEST) Indoor off fan cycle: (FAN, OFF CYCLE 10, 20, 30, 1 HR) Outputs Compressor output, COM Indoor fan, BLOWER LO, HI Outdoor fan, OUTDOOR FAN Electric heater, ELE Reversing valve, REV VALVE Keys and Indicators Labels ON/OFF, FAN SPEED, MODE FAN MODE, SLEEP 7 Push Buttons Temp buttons: for Temp UP and for Temp DOWN 9 LED Indicators LED 2 Digit Displays No Label SLEEP, COOL, COOL/DRY, FAN, HEAT, HIGH, LOW, CYCLE, CONT. Display Function Legend Tr = Room Temperature hi = High Room Temperature Lo = Low Room Temperature LA = Low Ambient Lockout = Secondary (Slave) Unit Touchpad Display - Indicates Unit is Controlled by a Master. Occurs when Slave Control Select Jumper is on SEC Pins rt = Remote Thermostat Control tp = Touchpad Control t = Time Ts = Temperature Setpoint Rf = Room Freeze Condition CF = Coil Freeze Protection F = Fahrenheit C = Celsius LC = Control Lockout Mode Turned ON nl = Control Lockout Turned OFF Catalog 1301-5 Page 9 of 32

16" x 44" Replacement Unit Features Premium (7-Day Programmable)Digital Touchpad Provides all the features of the Standard Controller, plus master/slave, infra-red control, auto damper, wall mounted remote thermostat, heat fan lockout. Figure 8: Premium (7 -Day Programmable) Digital Touchpad LED with Program Setting Display Digital Touchpad with Automatic Changeover from Cooling to Heating & Heating to Cooling Available with the Programmable LUI (668003802) and Premium Board (667997303) only. The Auto-Changeover board has a new control set with a touchpad label that shows, AUTO. The Auto Changeover control provides: Auto changeover from heat to cool and vice versa LED's from top down that read: Sleep, Cool, Auto, Fan, and Heat 9-LED Indicators 8- Push Button Display Inputs Figure 9: Digital Touchpad with Automatic Changeover from Cooling to Heating & Heating to Cooling Display Inputs: ON/OFF Turn the unit on and off Increase the temperature set point Decrease the temperature set point MODE Select one from the following modes: COOL, COOL/DRY, FAN, or HEAT FAN MODE Change the mode of fan operation between CYCLE and CONTINUOUS FAN SPEED Change the speed of the fan between HIGH and LOW SLEEP Activate the sleep mode and set the sleep time PROG ON/OFF Button to activate and deactivate the program mode Master-Slave Control (Optional) A single master unit can be configured to control up to 32 slave units. The master unit controls on/off, fan, settings and sleep functions for the secondary units. Cool/Dry Mode: In the cooling mode, this setting runs the fan on low speed, and cycles the compressor on and off when it gets within 2 degrees of the set point. Cycles decrease in length from 12 minutes to 8 minutes to 6 minutes with slightly longer fan cycles to keep the evaporator coil below the dew point. In a few words, it extends the cool cycle without sacrificing comfort for de-humidification. AUTO AUTO Non-Programmable Mode: Display shows both HEAT and COOL icons Temperature set point displays between the HEAT and COOL icons Setpoint is adjusted with Up and Down arrows Heating initiates when the room temperature falls one degree below the thermostat setpoint. Heating terminates when the room temperature reaches two degrees above the setpoint Cooling initiates when the room temperature reaches one degree above the thermostat setpoint. Cooling terminates when the room temperature falls two degrees below the setpoint AUTO Programmable Mode: HEAT and COOL icons alternatively flash with their respective programmed setpoints The system engages cooling and heating automatically to maintain respective setpoints according to system model selection The 2-degree gap between setpoints represents the deadband and is necessary to prevent unecessary switching between heating and cooling The 2 degree deadband provides the following: Heating activates when the room temperature is one degree below the thermostat setpoint plus the 2 degree deadband. Cooling activates when the room temperature is one degree above the thermostat setpoint plus the 2 degree deadband Page 10 of 32 Catalog 1301-5

16" x 44" Replacement Unit Features Wireless Remote Control (optional) Note: Only available on select models. The remote consists of 10 push-buttons Power: Functions the same as the ON/OFF button on the touchpad. Sleep: Functions the same as the SLEEP button on the touchpad Mode buttons Heat, Cool, Cool/Dry, Fan: Performs the same function as the MODE button on the touchpad and allows user to select the specific mode of operation using only one button. Temp buttons +, : Functions same as the buttons on the touchpad and allows the user to change the setpoint. Fan speed buttons (high & low): Performs same function as the FAN SPEED button on the touchpad and allows user to select the specific speed using only one button. The remote must be aimed in a line of sight of the window in the upper right corner on the front panel, at less than a 45 angle from center of the window. Catalog 1301-5 Page 11 of 32

PDAE Chassis Customization Options Table 1: Chassis Customization Options Description Unit Size Unit Type - PDAC 007 009 012 015 017 Cabinet Type Voltage 16 x 42 Angled Top 16 x 42 Flat Top 115-60-1 n/a n/a n/a 208/230-60-1 265/277-60-1 n/a 208/230-60-1 w/ standby 115-60-1 n/a n/a n/a 265/277-60-1 w/ standby 115-60-1 n/a n/a n/a 208/230-60-1 w/ standby (all sizes) Cooling Capacity BTUH 7,400 9,100 12,800 14,400 16,800 Heating Options Electric Heater (kw) 2.5 3.5 5.0 n/a n/a Hydronic - Hot Water or Steam Hydronic with Intermediate Electric (PDAA & PDAF Units) Air Flow CFM - High/Low Speed in Heating 380/340 550/380 Outside Air Damper - Vent - CFM -High/Low Speed 50/40 70/50 Damper Auto Damper Control (Standard for most Hydronic Heat) Manual Damper Control (Not available for most Hydronic Heat) (IAQ) Fresh Air Power Vent w/auto Damper Unit-Mounted Non-Programmable Unit-Mounted Programmable Unit Control Remote Hand-Held Infra-Red (IR) Unit-Mounted, Automatic Changeover Seacoast Coating Package Parts That Receive Special Treatment Wall Sleeve The entire CWS wall sleeve or cabinet/wall sleeve is constructed of A-60 galvanized, phosphatized, 18 gauge steel, specially treated, inside and outside, with a baked on epoxy based powder coat paint to protect it from the corrosive effects of salt spray. The BWS wall sleeve is constructed from galvanized, primed and pre-painted Antique Ivory 18 gauge steel. Sheet Metal Parts Are protected with Casing Guard coating which provides a comprehensive corrosion protection for all exposure conditions. Condenser Coil Is protected with E-Coating. This coating consists of an epoxy primer and acrylic topcoat that is electro-statically applied and baked on. Condenser Fan Blade and Slinger Ring Is constructed of Noryl PPO, which is a strong engineering plastic that has excellent flame resistance and dimensional stability over a wide range of service temperatures. Noryl has low moisture absorption and excellent strength and stiffness. Condenser Fan Motor Has a coating provided by the manufacturer and zinc end plates. Compressor Has a protective coating applied by the manufacturer to the exterior to enhance equipment life and performance. Outdoor Louver Made of aluminum, then etched and anodized for maximum corrosion protection. Etched, anodized aluminum louvers are available in a stamped or architectural style. n/a = not applicable Notes: For illustration purposes only. Not all options available with all models. Consult a Daikin Sales Representative for details and availability. Other Customization Options 16 x 42 Units Custom Sleeve - Extended depths, brick stops, or support legs can be added for panel wall or curtain wall applicatons. Custom Cabinet - Extended depths, colors, kickplates. Factory-installed valves and hydronic coils. Model PDAF Flat Top 16 x 42 ExtendAire - a cabinet extension kit designed to provide balanced heating and cooling in two rooms using a single unit. Page 12 of 32 Catalog 1301-5

AHRI Performance Data Table 2: AHRI Performance Data (6) Cooling Model 007 009 012 015 017 Volts 6 115 208/230 265 115 208/230 265 208/230 265 208/230 265 208/230 Btuh 1 7400 7400 7400 9100 9100 9100 12800 12300 14400 14400 16200 Sensible Btuh 1 6500 6500 6500 7500 7500 7500 9000 8700 9600 9600 11300 Cooling EER 11.6 11.6 11.6 11.1 11.1 11.1 10.0 10.1 9.5 9.5 9.3 Volts 115 208/230 265 115 208/230 265 208/230 265 208/230 265 208/230 FLA 5 7.43 4.07 3.34 9.33 5.45 4.04 7.15 6.09 8.21 6.69 10.03 Watts 1 638 638 638 820 820 820 1280 1218 1516 1516 1742 Electric Heat 2 2.5 kw 3.5 kw 5.0 kw kw 2.0/2.5 2.0/2.5 2.0/2.5 2.0/2.5 2.0/2.5 Amps 9.7/10.7 9.7/10.7 9.7/10.7 9.7/10.7 9.7/10.7 kw 2.7/3.4 3.3 2.7/3.4 3.3 2.7/3.4 3.3 2.7/3.4 3.3 2.7/3.4 Amps 13.2/14.6 12.3 13.2/14.6 12.3 13.2/14.6 12.3 13.2/14.6 12.3 13.2/14.6 kw 4.0/4.9 4.5 4.0/4.9 4.5 4.0/4.9 Amps 19.4/21.5 16.8 19.4/21.5 16.8 19.4/21.5 Hydronic Heat 3 Valve & Fan Motor Amps 0.74 0.41 0.32 0.74 0.41 0.32 0.41 0.32 0.41 0.32 0.47 Hot Water Btuh 18,400/15,600 18,400/15,600 18,400/15,600 18,400/15,600 23,200/16,400 Steam Btuh 22,400/22,300 22,400/22,300 22,400/22,300 22,400/22,300 27,900/23,300 Airflow High Low High Low High Low High Low High/Low Cool 360 330 360 330 360 330 360 330 540/360 Heat 380 340 380 340 380 340 380 340 550/380 Vent 50 40 50 40 50 40 50 40 70/50 Min. Circuit Ampacity Time Delay Fuses or Type HACR Ckt Breaker 2.5 kw 14.3 14.3 14.3 14.3 14.3 3.5 kw 19.3 16.4 19.3 16.4 19.3 16.4 19.3 16.4 19.3 5.0 kw 28.3 22.2 28.3 22.2 28.3 Hydronic Heat 8.69 4.77 3.89 11.06 6.49 4.77 8.48 7.22 9.8 7.97 12.1 2.5 kw 15 15 15 15 15 3.5 kw 20 20 20 20 20 20 20 20 20 5.0 kw 30 25 30 25 30 Hydronic Heat 15 15 15 15 15 15 15 15 15 15 15 2.5 kw 6-15R 6-15R 6-15R 6-15R 6-15R NEMA Receptacle 3.5 kw 6-20R 7-20R 6-20R 7-20R 6-20R 7-20R 6-20R 7-20R 6-20R 5.0 kw 6-30R 7-30R 6-30R 7-30R 6-30R Hydronic Heat 5-15R 6-15R 7-20R 5-15R 6-15R 7-20R 6-15R 7-20R 6-15R 7-20R 6-15R 1 2 3 4 5 6 Based on ASHRAE and AHRI test conditions of 95 F DB/75 F WB outside, 80 F DB/67 F WB inside. Electric Resistance Heat Watts x 3.41 = Btuh. Electric Heating Watts and Amps include Indoor Fan Motor. Water Based on ASHRAE and AHRI test conditions of 200 F EWT, 180 F LWT, 70 F EAT with a 1.8 gpm flow rate. 90 cfm with Power Vent Option. Cooling Full Load Amps includes Compressor, IDF and ODF FLA's. Electric Heat MCA, Time Delay Fuse or HACR Ckt Breaker, and NEMA Receptacle data are based on 240V and 277V = Not Applicable Catalog 1301-5 Page 13 of 32

Dimensional Data PDAE Air Conditioner with Electric Heat Table 3: Unit Weights (lbs.) Model 007 009 012 015 017 16" 42" Angled Top *16" 42" Flat Top PDAA Chassis 129.5 137 137.9 145.6 150.6 PDAA Packaged 144.5 152.0 152.9 160.6 165.6 PDAF 129.5 137 137.9 145.6 150.6 PDAF Packaged 144.5 152 152.9 160.6 165.6 * Includes Chassis and Cabinet Assembly (Wall Sleeve Ships Separate) Figure 10: Cabinet & Wall Sleeve and Chassis Finished Wall Line 16" x 42" Wall Sleeve Top View 10-1/2" (267mm) Minimum (Packaged)...28 lbs. (13 kg) Louvers Flush-stamped...6 lbs. (3 kg) Architectural...8 lbs. (3 kg) Subbase 3" (76mm) High Electrical...10 lbs. (5 kg). 4" (102mm) High Electrical...12 lbs. (5.4 kg) 8" (203mm) High Hydronic...20 lbs. (9 kg) 44-7/8" (1140mm) 1/2" (13mm) 20" (508mm) A A = Louver thickness: 16-3/8" (416mm) Flush Stamped 3/8" (10mm) Architectural 1-1/8" (29mm) 1-11/16" (43mm) 41-1/2" (1054mm) Front View 3" (76mm) or 4" (102mm) 6-1/4" (159mm) Side View 4-1/4" (108mm) to 13-3/4" (349mm) Page 14 of 32 Catalog 1301-5

Typical Installation The 16" 44" PDAE conditioner can be mounted flat on the floor for the lowest possible silhouette, off the floor at any convenient height, or on an optional universal telescopic subbase which adjusts to any wall thickness. Figure 11: Above-the-floor installation Figure 14: Typical room cabinet and wall sleeve Finished Wall Room Cabinet/Wall Sleeve Finished Floor Subbase 3 3 /8" (86mm) Louver Depth Louver Frame Outside Wall Figure 12: Installation on telescopic subbase 2" 2" Finished Wall Figure 13: Flat-on-the-floor installation 1/2" (13mm) Finished Wall Line 10 1 /2" (267mm) Min. Lintel (by others) 5/32" Dia. (typical of 2) Louver Depth Mortar Base Finished Floor Optional Subbase Outside Wall Refer to: Retrofit Kit (P/N 669548701 and IM 994-x for installation of PDAE 16" 44" Replacement Unit Chassis into Existing EA/PMES/PMRS Cabinet/Wall Sleeve with Front Return (Pages 1-2). Retrofit Kit (P/N 669548701 and IM 994-x 16" 44" Replacement Unit Chassis into Existing ES/RS/MQT Cabinet/Wall Sleeve with Bottom Return (Pages 3-4). Items Included in Kit: Replacement Front Panel Grille Tray Grilles Control Door Assembly Chassis/Cabinet Seals Blockoff Plate Notes: 1. Subbase is optional in 208/230V unit, but standard on 265V Louver frame is optional on all units. 2. If Replacement chassis is being installed in an existing bottom return S/RS/MQT cabinet/wall sleeve, the retaining bracket, located in the center top and inside the cabinet/wall sleeve, must be removed to allow the chassis to be completely inserted into the cabinet/ wall sleeve. It is held in place with a 1/4" philips head screw. Catalog 1301-5 Page 15 of 32

Accessories Quick Selection Guide Table 4: Wall Mounted Thermostats Quick Selection Guide Thermostat Item Number 91016771 910116772 910116774 Single Stage Two Stage Heat Pump Manual Changeover (Cool/Off/Heat) Settable Differential Range Auto Changeover Status LEDs Backlit Display 7-Day or 5-2-day or 5-1-1 Programmable Temporary Hold Programmable Fan On/Off Delay Non-Programmable Hard Wired Wireless 4 or 5 Wire Capable Freeze Protection Fan Switch - On/Auto Lockout Feature Fahrenheit or Celsius Display Remote Sensor Option Power Loss Memory Protection Anti-Short Cycle Delay Max./Min. Set Point Control Energy Management Interface California Title 24 Compliant Remote Thermostat Control The remote thermostat can be any thermostat that can interface with an electronic thermostat via RCBWYG terminals. The Control Selection jumper must be in T STAT position. During a call the remote thermostat will pass R back to the controller on a respective terminal. The push buttons on the touchpad become inactive in the remote thermostat mode. EXCEPT in T'STAT mode, the fan speed can be changed at the Touchpad and the fan mode is dictated by the Remote t'stat. However, the control pad LED display will indicate the mode of operation, and the room temperature. Note: In terms of outputs, there are two types of thermostats: relay contacts and solid state. If you open the thermostat and don t see relays then it must be solid state. Manufacturers of solid state output thermostats include loading resistors on their installation kits. They are of 560 Ohm and 3W value. These resistors are meant to load thermostat solid state outputs in order for the output voltage to be either 0 or 24VAC, i.e. no floating voltage. These resistors are connected from W, Y, G to common (C), respectively. You can wire any type of 24Vac thermostat straight into the REMOTE T STAT connector of PTAC control boards, 667997102, 667997203 and 667997303 (Basic, Premium and Auto-Changeover models) and the control boards will recognize the signals from them. Page 16 of 32 Catalog 1301-5

Accessories Wall-Mounted, Non-Programmable Thermostat Manual Changeover One-Stage Heat and Cool or One-Stage Heat Pump Part No. 910116771 (1-Pk, White) Requires Wall Plate (Part No. 910116770) Wall-Mounted, 7, 5-2 & 5-1-1 Programmable Thermostat Manual Changeover One-Stage Heat and Cool or One-Stage Heat Pump Part No. 910116772 (1-Pk, White) Requires Wall Plate (Part No. 910116770) Features and Benefits Hardwired Simple operation Large LCD display No batteries required A/C compressor protection - 5-minute time delay to protect compressor after it turns off Single stage heat pump Freeze protection feature Zone capatible 4- or 5-wire compatible (C is optional for non-heat pump systems) Manual Changeover Specifications Electrical Rating: 24 VAC (18 to 30 VAC) 1 amp maximum per terminal 3 amp maximum total load 30-minute power loss memory retention Temperature Control Ranges: 45 F to 90 F, Accuracy: ± 1 F System Configurations: 1 stage heat, 1 stage cool or single stage electric heat pump Terminations: R, C, W, Y, O, B, G Features and Benefits Simpleset TM logical programming for set-up and set-back temperatures and times Simpleset TM feature enables easy copying of one day s programming for the entire week Programmable fan to circulate air during any program setting. Vacation hold overrides programming Enables separate morning, day, evening, and night settings for every day of the week Clear, backlit display makes it easy to see time, temperature, and setpoint even in the dark A/C and heat pump modes 4-minute time delay to protect compressor after it turns off Lockout feature prevents unwanted tampering Manual Changeover Specifications Electrical Rating: 24 VAC (18 to 30 VAC) 1 amp maximum per terminal 3 amp maximum total load 30-minute power loss memory retention Easy access terminal block Temperature Control Ranges: 45 F to 90 F, Accuracy: ± 1 F System Configurations: 1 stage heat, 1 stage cool or single stage electric heat pump Terminations: RC, RH, C, W, Y, O, B, G Catalog 1301-5 Page 17 of 32

Accessories Programmable - Standard Auto or Manual- Changeover Two-Stage Heat/Two Stage Cool Part No. 910116774 (1-Pk, White [Thermostat Only with Wall Plate]) Part No. 910116773 (1-Pk, White [Thermostat with Wall Plate & Remote Sensor]) Optional Remote Sensor Part No. 667720401 (Used in Conjunction with Thermostat Part No. 910116774 Only) Features and Benefits Simpleset TM logical programming for set-up and set-back temperatures and times Simpleset TM feature enables easy copying of one day s programming for the entire week Programmable fan to circulate air during any program setting. Vacation hold overrides programming Enables separate morning, day, evening, and night settings for every day of the week Clear, backlit display makes it easy to see time, temperature, and setpoint even in the dark Automatically switches between heating and cooling modes A/C and heat pump modes 4-minute time delay to protect compressor after it turns off Lockout feature prevents unwanted tampering Optional remote temperature sensor available The Fast, Easy Solution For Temperature Sensing Problems. For tamper prone areas Poor airflow areas Troubled applications Foam gasket prevents drafts through wall opening Mounts to standard 2" 4" outlet box 2 3 /4"W 4 1 /2"H Wireless Temperature Control (T9000) The T9000 Wireless Temperature Control is designed to provide precision temperature control without the installation labor and expense of wiring. Powered by AA batteries Mounts in any suitable location that will provide good temperature control. Large LCD display provides the user with current room temperature, set point temperature, time, program interval, and other system status information. Specifications Electrical Rating: 24 VAC (18 to 30 VAC) 1 amp maximum per terminal 4 amp maximum total load 30-minute power loss memory retention Easy access terminal block Temperature Control Ranges: 45 F to 90 o F, Accuracy: ± 1 F System Configurations: Single or two-stage heat/cool Single or two-stage heat pump Terminations: R, C, W1/O/B, Y1, W2, Y2, G Programmable Non-Programmable Remote Control Node (RCN) Used with the Wireless Temperature Control, the RCN interfaces with specific HVAC equipment, and communicates with its thermostat using unlicensed 900 MHz, radio frequency energy. Contact your local Daikin Representative for details. Page 18 of 32 Catalog 1301-5

Accessories Electrical Subbase 3" or 4" High Figure 15: Electrical Subbase Details 3" 5" Opening for Electrical and/or Drain Rough-In Electrical Junction Box for Main Power Connection An electric subbase is available for the PDAC unit. The subbase height can be either 3" or 4". Leveling legs are supplied with the subbase which allow for an additional 1" adjustment. The electrical subbase requires a minimum of 4 3 /8" from the front edge of the wall sleeve to the finished wall. Knockouts for Optional Fuse & Disconnect Switch Receptacle (Req d on 265V Units) Plug/Cord Cover (Req d on 265V Units) Subbase Side Dimension: Electric: Adjustable from 4 3 /4" to 13 3 /4" (111mm to 349mm) Subbase Height Dimension: Electric: 3" to 4" (76mm to 102mm) with 0" to 1" (0mm to 25m) leveling screw Subbase Weight: 3" (76mm) High Electrical = 10 lbs. (5kg). 4" (102mm) High Electrical = 12 lbs. (5.4kg) Notes: 1. Subbase is optional on 208V and 230V units. Subbase is standard on all 265V units and units with hydronic heat. Electric subbase is flush with wall sleeve. 2. Subbase extends to front edge of unit when furnished with hydronic heat. 3. Opening needs to be 16 5 / 8 " 42 5 / 8 " (422mm 1083mm) when using a louver frame. Figure 16: Electrical Subbase Dimensions 7/8" Electrical Knockouts 5/8" 0" to 9-3/8" 3" 4-3/8" 5" 17" 12" 2-1/2" Plan 1-1/2" 41-1/2" 3" or 4" Leveling Screw (4 Places) 0" to 1" Front Elevation (Three Front Panels in Place) Catalog 1301-5 Page 19 of 32

Accessories Hydronic Subbase 8" High Heat Section Note: Used with bottom return air configuration only. Figure 17: Hydronic Subbase Details Hydronic Coil Hardware Bag Receptacle Permanent Filter Hinged, Louvered Front Panel Adjustable Side Channels The PDAC hydronic model requires 1" minimum from the front edge of the wall sleeve to the finished wall. Side channels are furnished with all subbases for a maximum depth extension of 13¾". Subbases are available with or without receptacles or fuse disconnect switches 2-row, finned/tube coil furnished for either hot water or steam and mounted in an 8" subbase. 5/8" O.D. copper pipe connections supplied. The louvered subbase front panel is hinged, with quick-release latches for easy access to piping, valves and the 1/2" permanent filter. Notes: 1. Side channels are adjustable from 0" 9 3 /8" in length by inverting them. Side channels are predrilled to allow infinite adjustment. 2. Front panel is hinged to allow access to valve, coil, filter & electrical junction box. 3. Leveling legs are adjustable from 1/4" 1 /4". Hydronic Subbase Weight 8" (203mm) High Hydronic = 20 lbs. (9 kg) Figure 18: Hydronic Subbase Dimensions (Shown with Front Panel Removed) As Req d 3/4" Receptacle (Factory installed when fuse & disconnect are furnished) 2 1 /2" 15" Fuses 8 1 /4" 3" x 5" Opening for Electrical and/ or Piping Rough-in Optional Disconnect 5/8" O.D. Copper Sweat 2 1 /2" Top View 7 1 /4" Permanent Mesh Filter 6 3 /4" 7 1 /2" 1 1 /2" 3 1 /4" Electrical Knockout 8" 3/4" 41 1 /2" 5 1 /2" 1/4" 1 1 /4" Leveling Legs Front View End View Page 20 of 32 Catalog 1301-5

Accessories Drain Kits Drain kits may be used on any unit as required. They eliminate excessive condensate accumulation. There are two types of drain kits employed with the Packaged Terminal equipment; internal drains and external drains. Internal Drain An internal drain is mounted to the bottom of the wall sleeve prior to installation of the sleeve. Position this drain on the room side of the sleeve and connect to an internal collection system. When using a subbase, a 3" 5" opening is provided in the subbase for plumbing to the drain. External Drain The external drain is attached to the rear of the wall sleeve, over one of the weep holes. A cap is provided to seal the remaining weep hole to force the excessive condensate to one side. The excess condensate is then evacuated from the wall sleeve and allowed to drain to the outside of the building. Figure 19: Internal Drain Kit Contractor To Drill Three (3) Holes To Accept Drain Kit Room Side See Detail Square Drain Holes Neoprene Sponge Gasket Steel Mounting Plate Figure 20: External Drain Kit Room Side Neoprene Sponge Gasket Steel Mounting Plate Square Drain Holes 1/2" (13mm) O.D. Drain Tube Alternate 6" Long, 1/2" O.D. Straight Copper Tube Note: Use of 6" straight drain tube will require modification of architectural louver. Catalog 1301-5 Page 21 of 32

Accessories Wall Sleeve Extension PDAE 16" 44" Replacement Unit The standard wall sleeve will accommodate the maximum wall thickness described in Table 5. For thicker walls, wall sleeve extensions are available from your local distributor. Air splitters will be included in the wall sleeve extension as shown in the illustrations below. Note: When installing a new chassis into an existing wall sleeve with an extension, it will be necessary to relocate the two air splitters to match the dimensions shown in the illustrations (see Table 6). Figure 21: 16" 44" Replacement Unit as required B Room Side Table 6: Wall Sleeve Extension Splitter Location Dimensions Dimension 16" x 44" Replacement Unit A 11 7 /8" B 25" C 7 5 /8" Louver Frame Louver frames should be used for panel wall and thin wall applications to assure positive anchoring to the wall. The cabinet/wall sleeve is installed flush with the outside of the building. The louver frame is placed around the cabinet/wall sleeve. Figure 22: Louver Frame Dimensions 16" 18 5 /8" (473mm) A Air Splitters 45" (1143mm) B 44.5" C Wall Sleeve Extension 3 3 /8" (95mm) 16 1 /2" (419mm) 47 1 /8" (1197mm) Table 5: Maximum Wall Thickness without Sleeve Extensions Maximum Wall Thickness Louver No Standard Type Subbase Subbase Architectural 1 /8" 14 7 /8" 10 3 /8" Note: Wall Sleeve rough opening when using a Louver Frame must be 16 5 /8" 45 1 /8" Page 22 of 32 Catalog 1301-5

Accessories Louver The attractive, rugged architectural louver is extruded aluminum and is finished natural and clear anodized (optional colors are also available). Louvers by others are acceptable as long as they meet factory specifications. They must have a minimum free area of 70% or a pressure drop not exceeding.05 in. w.g. at 300 fpm face velocity, and a blade design that will not cause recirculation of condenser air. Architectural Louver Louver Weight Architectural = 8 lbs. (3kg) Notes: 1. Optional architectural extruded aluminum. 2. Louver can be installed from inside the building. NOTICE Airflow required for PTAC units must not be restricted by exterior plants or walls. Plants or shrubs must not be planted in close proximity to the outside grille of the PTAC unit. Vegetation planted too close to grilles will cause discharge air to be recirculated, thereby increasing electrical consumption. Warranty will be voided if it is determined that the compressor life is shortened from overheating due to close proximity of outside obstructions Note: Discharge air restrictions include, but are not limited to: Vegetation Concrete walls or barriers Overhangs that do not allow discharge air to rise Installation of bug screen of any kind Outdoor louvers by others unless approved by the factory Figure 23: Architectural Louver Dimensions Blade Profile (Reference) Threaded Insert (4) Blockoff Blockoff Section A-A Catalog 1301-5 Page 23 of 32

Accessories ExtendAire Kit The ExtendAire plenum system is internally lined with 1/4" (6mm) fiberboard, 6 lb. (13.2 kg) density to prevent condensation on the exterior surface. Factory painted Antique Ivory, matching the finish of the basic cabinet. Each extension section is furnished in two pieces such that the rear half can be fastened to the wall and the front half then snapped in place without the use of screws or tools. Duct cross-sectional dimension is 4½" 10½". The installer can select the number of active grilles in the primary discharge section that will provide diversion of the specified percentage of air to the adjoining room outlet. Refer to grille configurations and capacity percentages in Table 7, 8 & 9. The percent air diverted can be adjusted from 20% to 50%. The ExtendAire kit is available with an optional internal Boost Fan, (H in Figure 26) that will be field-installed. When a 3 foot (or greater) extension section is added to the primary section, the (optional) boost fan is recommended. The Boost Fan operates when the indoor fan operates, to assist unit airflow into the adjoining room. Typical ExtendAire Configurations Figure 24: Side Wall Outlet Assembly Figure 25: Shelf Discharge Assembly Table 7: Side Wall Outlet Assembly without Boost Fan Primary Primary Room Adjoining Room Approximate Active Approximate Approximate Total System Grilles Capacity % Capacity % CFM 5 60% 40% 302 Table 8: Side Wall Outlet Assembly with Boost Fan Primary Primary Room Adjoining Room Approximate Active Approximate Approximate Total System Grilles Capacity % Capacity % CFM 3 20% 80% 334 4 30% 70% 374 5 40% 60% 410 Table 9: Shelf Discharge Assembly with Boost Fan Primary Primary Room Adjoining Room Approximate Active Approximate Approximate Total System Grilles Capacity % Capacity % CFM 4 40% 60% 311 5 50% 50% 356 Figure 26:Typical ExtendAire Application A. ExtendAire section primary discharge D. Communication cord G. Trim Piece B. 3' Extension Section E. Removable discharge grilles H. Boost Fan (Optional) C. Touchpad control F. T bar hold-down clamp Page 24 of 32 Catalog 1301-5

Wiring Diagrams Premium (Programmable) Digital Control 1 Jumper Placement to Select System Module (See Jumper Detail) A Place jumper across AC/HYD to select Air Conditioner/Hydronic Heat. B Place jumper across AC/E to select Air Conditioner/Electric Heat. C Place jumper across AC/HYD/E to select Air Conditioner/Hydronic/Electric. 2 Jumper Placement to Select Fan Control: A When in Fan Cycle Mode, fan operates for 2 minutes. Place jumper across 10, 20, 30, or 1 HR to select fan cycle off minutes which will be overridden by the room temperature. 3 Jumper Placement to Select Controller Type: A Place jumper across LUI to select unit mounted touchpad (Local User Interface). B Place jumper across SLAVE to select SLAVE Control by a master unit. C Place jumper across T STAT to select remote, wallmounted programmable, or non-programmable thermostat. 4 Jumper Placement to Select Hydronic Valve: A Place jumper across NO to select Normally Open Hydronic Valve. B Place jumper across NC to select Normally Closed Hydronic Valve. Jumper Placement Detail 3 1 A B C D E 2 A A B C 4 B A Wiring Diagram Legend CT = Control Transformer DM = Damper Motor CM = Compressor Motor IFM = Indoor Fan Motor OFM = Outdoor Fan Motor HFLO = Heat Fan Lockout Sensor OCS = Outdoor Coil Sensor OAS = Outdoor Air Sensor ICS = Indoor Coil Sensor IAS = Indoor Air Sensor LUI = Local User Interface HYV = Hydronic Valve REV = Reversing Valve EHC = Electric Heat Contactor Catalog 1301-5 Page 25 of 32

Wiring Diagrams Standard (Non-Programmable) Digital Control 1 Jumper Placement to Select System Module (See Jumper Detail) A Place jumper across AC/E to select Air Conditioner with Electric Heat. 2 Jumper Placement to Select Fan Control A When in Fan Cycle Mode, fan operates for 2 minutes. Place jumper across 10, 20, 30, or 1 HR to select fan cycle off minutes which will be overridden by the room temperature. 3 Jumper Placement to Select Controller Type: A Place jumper across LUI to select unit mounted touchpad (Local User Interface). B Place jumper across T STAT to select remote, wall mounted programmable, or non- programmable thermostat. 1 A B C Jumper Placement Detail 3 2 B A A Wiring Diagram Legend CT = Control Transformer CM = Compressor Motor IFM = Indoor Fan Motor OFM = Outdoor Fan Motor OCS = Outdoor Coil Sensor OAS = Outdoor Air Sensor ICS = Indoor Coil Sensor IAS = Indoor Air Sensor LUI = Local User Interface REV = Reversing Valve EHC = Electric Heat Contactor Page 26 of 32 Catalog 1301-5

Wiring Diagrams Digital Control Board with Standby Power The standby power connections, L1 STBY and L2 STBY are meant to run the indoor motor at a separate voltage from the other motors, compressor and outdoor motor. When used as such, the jumpers, JH1 and JH2, must be cut. This renders L1 & L2 and L1 STBY and L2 STBY isolated from each other. If there is no need to run the motors at a separate voltage the L1 = L1 STBY and L2 = L2 STBY. Therefore one voltage is used to run all motors. If the jumpers are accidentally cut, then the connections can be spliced to substitute for the missing jumpers. Table A Wire Color Voltage WH 120V RD 208V OR 240V BN 277V Legend DM = Damper Motor HYV = Hydronic Valve CM = Compressor Motor IFM = Indoor Fan Motor OFM = Outdoor Fan Motor HFLO = Heat Fan Lockout Sensor OCS = Outdoor Coil Sensor OAS = Outdoor Air Sensor ICS = Indoor Coil Sensor IAS = Indoor Air Sensor LUI = Local User Interface REV = Reversing Valve IR = IR Receiver Board (AP7810) C1 = Indoor Motor Capacitor C2 = Outdoor Motor Capacitor C3 = Compressor Capacitor MP = Motor Protector Note: The gray tinted areas in the wiring diagram; are options available only with the premium control board. For the latest drawing version refer to the wiring diagram located on the inside of the controls access panel of the unit. Catalog 1301-5 Page 27 of 32

Wiring Diagrams Digital Control Board Without Standby Power The standby power connections, L1 STBY and L2 STBY are meant to run the indoormotor at a separate voltage from the other motors, compressor and outdoor motor. When used as such, the jumpers, JH1 and JH2, must be cut. This renders L1 & L2 and L1 STBY and L2 STBY isolated from each other. If there is no need to run the motors at a separate voltage the L1 = L1 STBY and L2 = L2 STBY. Therefore one voltage is used to run all motors. If the jumpers are accidentally cut, then the connections can be spliced to substitute for the missing jumpers. Table A Wire Color Voltage WH 120V RD 208V OR 240V BN 277V Legend DM = Damper Motor HYV = Hydronic Valve CM = Compressor Motor IFM = Indoor Fan Motor OFM = Outdoor Fan Motor HFLO = Heat Fan Lockout Sensor OCS = Outdoor Coil Sensor OAS = Outdoor Air Sensor ICS = Indoor Coil Sensor IAS = Indoor Air Sensor LUI = Local User Interface REV = Reversing Valve IR = IR Receiver Board (AP7810) C1 = Indoor Motor Capacitor C2 = Outdoor Motor Capacitor C3 = Compressor Capacitor MP = Motor Protector Note: The gray tinted areas in the wiring diagram; are options available only with the premium control board. For the latest drawing version refer to the wiring diagram located on the inside of the controls access panel of the unit. Page 28 of 32 Catalog 1301-5