CONTROL PANEL INSTRUCTIONS RSQ-4

Similar documents
HEAT PUMP WATER HEATER (EEV) CONTROLLER PANALE INSTRUCTION SH-16G2-C-KP (V1.0)

Operating Functions Temperature Parameters

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

BTU Units WORKING PROGRAM MANUAL

Technicians Manual Single Compressor

OPERATION INSTRUCTIONS DEMAND DEFROST CONTROL BOARD MODEL FOR USE WITH MODELS: AFFINITY, ECHELON, ACCLIMATE HEAT PUMP SERIES

SEMTIC HEATING

Wired controller KJR-08B/BE. Run. Fault. TB Tot. Out. Query. Heat. Net-On. Turn-On Mode

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6535D, 6537C, 6538 A&B SERIES TWO TON PACKAGED HIGH EFFICIENCY HEAT PUMPS

OWNER S MANUAL. Vintage Classic HEAT COOL models. Proudly Made in the USA

Wired Controller XK60

HP727S. Single speed swimming pool heat pump controller Operation manual TABLE OF CONTENTS

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

OPERATING INSTRUCTIONS

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP 100% OUTSIDE AIR

MR4PMUHV Electronic. Temperature/Defrost Control with Relay Pack

SPECIFICATIONS for AIR CONDITIONING CONTROLLER ZONE CONTROL

User Guide ems25plus. Page 1. Normal operation. Product interface

INSTALLATION AND USER MANUAL

Field Setting for Smart IOT Inverter Outdoor Unit

INSTALLATION AND USER MANUAL

INSTALLATION AND USER MANUAL

ReFreeX H426V1 User manual

3. INDOOR UNIT OPERATION

AIR TO WATER HEAT PUMP USER MANUAL

WORKING PROGRAM. Heating dehumidifying cooling T 27

HOSHIZAKI AMERICA, INC. SERVICE BULLETIN

Wired Remote Controller XK19 and Wireless Remote Controller YT1F

SWIMMING POOL HEAT PUMP UNIT Installation & Instruction Manual Duratech - series

Sensor Control Panel

INSTALLATION & OPERATION MANUAL

User instructions DHP-AT

EXD-HP1/2 Stand-alone Superheat/Economizer Controller

Service Manual. Room Air Conditioner Split Wall-Mounted Type. Applies to: HSG-09HRN1 HSG-12HRN1 HSG-18HRN1 HSG-24HRN1

CHILLER. Modelli CWS BASIC CWS AQUACONTROL INSTALLATION MANUAL USAGE AND SCHEMATICS

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

QUICK REFERENCE GUIDE P.C. BOARD/WALL THERMOSTAT FOR 6536A891, 6536B891 & 6536C891 TWO TON PACKAGED HEAT PUMPS

Q-Logic Digital Controls The Q3 and Qht for Direct Expansion Systems

DC INVERTER SERIES AIR TO WATER

SERVICE MANUAL FOR 6537 & 6538 SERIES TWO TON HIGH EFFICIENCY PACKAGED HEAT PUMPS

Please read this manual carefully before installation and use.

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

Ductless Split Air Conditioner

CAREL CONTROLLER. Programming Instructions HOW TO CHANGE LEVEL 1 CONTROL SETTINGS HOW TO CHANGE LEVEL 2 CONTROL SETTINGS

Contents. FX-1 Operations Manual Micro Air Corporation 124 Route 526 Allentown, NJ 08501

Refrigerated air dryers

L SERIES UNITS 504,520M. 10/2001 Supersedes 504,413M

Public. Altherma by Daikin. Altherma Commissioning Service Field Settings

Installation and Operating Manual

Installation and Operation Guide For MCF-49FD, MCF-23FD MCR-49FD, MCR-23FD

CLEVER CONTROL Version: V3

Local Air Conditioner

SWIMMING POOL HEAT PUMP UNIT. Installation & Instruction Manual

User Manual for the. ACCS-1 Digital 7 Day Programmable Thermostat with Zone Control

Technical Manual Binair Monobloc Heat Pump

Remote Controller Manual

Mini unitary chiller. Mini unitary chiller

DC INVERTER AIR TO WATER HEAT PUMP AC series Heating & Cooling series CX45

Commercial Series. Power switch & Nameplate location: NAMEPLATE: Single and Dual Section

TREO SERVICE MANUAL. Models WALL MOUNTED SPLIT-TYPE AIR CONDITIONERS. No.TE CONTENTS

40KMC KMQ

CAREL IR33+ CONTROLLER

REACH-IN SAFETEMP (-AAC)

Model Number Nomemclature... 1 Specifications... 3 Refrigeration System... 4 Freezer and Refrigerator Air Circulation... 5 Display Designs...

ST76/96 series instructions

4. ALIGNMENT AND ADJUSTMENTS

REMOTE CONTROL FOR CHILLER MYCHILLER

DC INVERTER AIR TO WATER HEAT PUMP AC series Heating & Cooling series CX30

Digital Precise Air Control - DPAC

User manual CLIMATIC 200/400 - Controller. Providing indoor climate comfort

CXM/DXM. Application, Operation & Maintenance Instructions 97B0003N08 Revision: 01/10/05. CXM/DXM Digital Heat Pump Controllers.

COLDWAVE. Portable Air Conditioner. Model MPPD-12CRN BTU/h 110V/1Ph/60Hz R410A

Model: PRT2-TS / PRT2-NTS EU. Model: Touch Duo

Instruction manual Harmo PAC ZVWX1017/1022/1032/1041/1055/1056/1061

Installation & Operation Instructions

Floor-Standing Type(E Series)

Installation, Service and User Manual DTW 300 SP

SERVICE MANUAL. Model No. HSU09VHJ(DB) Wall mounted Type DC Inverter EA-Series WARNING. Haier Group. Order No.AC1101S020V0

Thermometers and temperature controllers

Swimming Pool Heat pump Instruction manual Harmo PAC series (Type ZVWX1017, ZVWX1023, ZVWX1033, ZVWX1042, ZVWX1052, ZVWX1057, ZVWX1062)

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

Quick Reference. Air to Water Heat Pump Series 4 Lot 1 Standard & Powerful Types

Heat Pump Defrost Board Replacement Kit

ERC2 Control Instructions

AIR TO WATER HEAT PUMP SERVICE MANUAL Versati II

FX BLAST CHILLER ISO ISO 9001

Dixell Installing and Operating Instructions release 7.0

DC INVERTER MONOBLOCK AIR TO WATER HEAT PUMP AND CHILLER. User Manual

Electronic Pellet Burner Controller NPBC-V3-1

TECHNICAL SERVICE DEPARTMENT Technical Service Bulletin Heat Pump Water Heater (Generation 4) Troubleshooting (Effective 1 Nov 2016)

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

SERVICE INSTRUCTION R410A. WALL MOUNTEDtype SPLIT TYPE ROOM AIR CONDITIONER INVERTER. Models Indoor unit Outdoor unit AO* R09LECN AO* R12LECN

SERVICE MANUAL Room Air Conditioner Multi Split Type Indoor units Light Commercial Series

Content Precaution...2 Function...3 Dimension...5 Refrigerant cycle diagram...7 Operation limits...8 Wiring diagram...9 Installation details...

I/O ZONE 560/583 AND OPERATION MANUAL

Model: Touch-RS. 1 Touch-RS

Inverter Swimming Pool Heat Pump

Rooftop Thermostat Controller Specification and Installation Instructions. Model TRT2422

High Wall Split Systems Cool Only 9K - 12K - 18K - 24K. Auto. Auto. Fan Speed. Smart LCD Wireless Control. Auto Mode.

Transcription:

CONTROL PANEL INSTRUCTIONS RSQ-4 FOR SIRAC AIR TO WATER HEAT PUMP (SINGLE COMPRESSOR, AIR TO WATER)

1) System Configuration This system is composed of mainboard and wire control panel. 146mm Φ4 4 Mainboard 90mm Wire Control Panel LCD Display 2) Panel Regulation The sign of Compressor 2

The sign of water pump The sign of fan motor The above signs will show up on the display screen if the corresponding components are working. The sign of defrosting The above sign will show up on the display screen if the unit is in defrosting state. 1. On/off Button Press On/Off button to switch on/off the unit. Press this button when the unit is in automatic On/Off state will abort the state 2. Set Button Hold Set Button for five seconds and then Up/Down Button to set parameter values. 3. Timer Button Press Timer Button then Up/Down Button to set unit automatic on/off time. First Press: set HOUR digit for unit automatic on; Second Press: set MINUTE digit for unit automatic on; Third Press: set HOUR digit for unit automatic off; Fourth Press: set MINUTE digit for unit automatic off. Fifth Press: exit Timer state. Note: when the set times for automatic on and off are the same, the timer setting will become invalid. Hold Timer Button for five seconds to set clock time. First Press: set HOUR digit of the clock time. Second Press: set MINUTE digit clock time. Third Press: exit clock time setting. Note: if no action is made in five seconds, the controller will exit setting state. 4. Up Button Press Up Button to set temperatures or time upwards. 5. Down Button Press Down Button to set temperatures or time downwards. 6. Temp Button Press Temp Button to check Evaporator Coil Temperature and Ambient Air Temperature. 7. Mode Button Press Mode button to select the activation or inactivation of backup electricity heating function. 3

3 Function 1. Heating Ti Inlet Water Temperature Td Set Temperature Differential (P0) Ts Set Water Temperature When Ti Ts Td the compressor is started. When Ti Ts 1 C the compressor is shut down. Remarks: The start or shutdown of the compressor is subject to time delay protection of the unit ( three minutes minimum). 2. Fan Motor Control The fan motor will begin to work after the compressor is started; the fan motor will cease after the compressor is shut down. Remarks: Exceptional in defrost mode. 3. Time Delay Protection of Compressor The compressor can be restarted only at least three minutes after the compressor is shut down. 4. Sensor Fault Protection Water Temperature Sensor Fault Close all outputs Evaporative Coil Temperature Sensor Fault Close all outputs Ambient Air Temperature Sensor Fault: Close all outputs 5 Water Flow Switch Protection If the water flow switch is observed to be disconnected for ten seconds continuously, water flow protection will be activated and all outputs will be closed. Remarks: Water flow switch will only be checked twenty seconds after the unit is started. The unit from Sirac does not come with a water flow switch and it is strongly recommended that a water flow switch is installed to protection the unit from damage resulting from water pump failure or insufficient water flow. 6 Water Pump Control The controller PCB board can send signals to control the water pump if water pump is wired to it (which is recommended). Water pump with a power input bigger than 200W should be connected to the PCB board via a relay. The water pump will begin to run 10 seconds before the compressor is started, and stop 30 seconds after the compressor is shut down. When the unit is in standby state, the water pump will run when Ti Ts Td. After 60 sec if this condition is still satisfied, the compressor will start. Otherwise the compressor will not start and the water pump will also stop. 7 Defrost Control Defrost Cut-in Conditions only when both conditions are satisfied a. Compressor continuous running time Defrost Cut-in Time (P2) b. Evaporator Coil Temperature Defrost Cut-in Temperature (P3) When the unit enters defrosting mode, the 4-way reversing valve will de-energize, directing the 4

hot gas to the evaporator coil. The fan motor will stop but the compressor and pump will continue working. Defrost Cut-out Conditions when either condition is satisfied a. Evaporator Coil Temperature Defrost Cut-out Temperature (P5) b. Defrosting time Defrost Cut-out Time (P4) When the unit reverts to heating from defrosting mode, the 4-way reversing valve will energize and the fan motor will begin to work. Forced Defrost: When the unit is in standby state, hold Down button for five seconds will lead to forced defrost function. After any Defrost Cut-out condition is satisfied, the unit will drop out of defrost state. 8. Backup Electricity Heater Control Cut-in Condiditons: a. Ambient air temperature is lower than backup electricity Heater cut-in air temperature (P6) b. The backup electricity heating function is activated ( See Mode Button). c. Ti<Backup Electricity Heater Cut-in Water Temperature (P7) d. The compressor running time is bigger than the Backup Electricity Heater Cut-in Time (P8) Only when all the above conditions are satisfied will the backup electricity Heater start. Cut-out Conditions: a. Ambient air temperature is higher than backup electricity Heater cut-in air temperature (P6) b. The backup electricity Heater is inactivated (See Mode Button) c. Ti>Backup Electricity Heater Cut-in Water Temperature (P7) When any of the above conditions is satisfied, the backup electricity Heater will stop working. 9 High Pressure Protection When the high pressure switch jumps off, the unit will enter high pressure protection. 10 Low Pressure Protection When the low pressure switch remains jumpoff state for a continuous 10 seconds, the unit will enter low pressure protection. 11 Anti-freeze Protection During unit off state ( power is not disconnected), the unit will be switched on to heat the water automatically if the water is observed to be below 3 C for a continuous sixty seconds. After the water temperature is above 15 C, the unit will be shut down. 12 Anti-bacteria Function Based on parameter values set in P9, Pa, Pb, Pc and Pd, the heat pump will automatically and periodically start the back-up electricity heater in the hot water tank ( if installed and controlled by the heat pump PCB board) to raise the water temp to a high level to kill harmful bacteria in the hot water. 5

The backup electricity heater will run once every [P9] days. The backup electricity heater will automatically start at clock time [Pa] [ Pb]. The water temperature needs to be kept at above [Pc] for [Pd]. Cut-in Conditions.Backup Electricity Heater is valid.p9 is satisfied.pa and Pb are satisfied When all the above conditions are satisfied, the unit will enter Anti-bacteria state Cut-out Conditions.Backup Electricity Heater is inactivated.pc and Pd are satisfied. When either of the above condition is satisfied, the unit will drop out of Anti-bacteria state. 4) Display of Errors No Input Port Fault Code Protection 1 /// Communication Error E0 Close all outputs 2 CN4 Inlet Water Temperature E1 Close all outputs Sensor Fault 3 CN5 Evaporator Coil Temperature E2 Close all outputs Sensor Fault 4 CN6 Ambient Air Temperature E3 Close all outputs Sensor Fault 5 HP High Pressure Protection E4 Close all outputs 6 LP Low Pressure Protection E5 Close all outputs 7 SHUI Insufficient Water Flow Protection E6 Close all outputs 5) Temperature Checkup Code Parameter 0 Evaporator Coil Temperature 1 Ambient Air Temperature 6) Parameter Setting 6

Parameter Range Default Set Water Temperature 25 C 60 C 40 C P0 Set Inlet/Outlet Water 1 C 10 C 5 C Temperature Difference P1 Temperature Precision 0 C 10 C 0 C P2 Defrost Cut-in Time 20min 90min 45min P3 Defrost Cut-in Temp -15 C 5 C -5 C P4 Defrost Cut-out Time 3min 15min 8min P5 Defrost Cut-out Temp 5 C 25 C 15 C P6 Backup Electricity Heater -10 C 12 C 6 C Cut-in Air Temp P7 Backup Electricity Heater 30 C 45 C 35 C Cut-in Water Temperature P8 Backup Electricity Heater 45min 60min 50min Cut-in Compressor Running Time P9 Anti-bacteria Interval 1 day 7 day 3 day Period Pa Anti-bacteria On Hour Digit 0 23 0 Pb Anti-bacteria On Minute 0 59 0 Digit Pc Anti-bacteria Temp 50 C 65 C 60 Pd Anti-bacteria Duration 0 min 300 min 120 min 7