Heat Pumps M2 SERIES. Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features:

Similar documents
Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Heat Pumps SB SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (3-18 tons) Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

Heat Pumps SA SERIES. Vertical Self-Contained Unit Water-Source Heat Pumps (23-70 tons) Features:

PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE / GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNTS. RQ Series.

RN/RQ. Series PACKAGED ROOFTOP UNITS, AIR-SOURCE HEAT PUMPS, WATER-SOURCE/ GEOTHERMAL HEAT PUMPS, & OUTDOOR AIR HANDLING UNITS.

CONDENSERS AND CONDENSING UNITS

ALL PRODUCTS BROCHURE

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

From 230 tons to. Water-Source Heat Pump Products. Premium Performance Environmentally Friendly Superior Construction

Series PACKAGED ROOFTOP UNITS, HEAT PUMPS AND OUTDOOR AIR HANDLING UNITS. Features:

Series. Packaged Rooftop Units, heat pumps and Outdoor air handling Units. Features:

Innovative Design, Performance, & Serviceability

Series. Chillers and. Features: Application Flexibility Minimizes Installation Time and Reduces Cost

Water-Source Heat Pumps

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

D-PAC. Digital Precise Air Control System. Functionality Factory Testing Ease of Installation Ease of Maintenance Energy Efficiency

DX Units. Ranging from 15 to 750 tons and 1,000 to 300,000+ CFM

THE ULTIMATE ROOFTOP SOLUTION

System Components with ` Emphasis on Packaged Rooftop Application and Installation. Jerry Cohen President Jacco & Assoc.

RoofPak Applied Rooftop Systems

PRODUCT SERIES. VPR Series VPRX Series VPRE Series VPRP Series VPRC Series

Bring the fresh in. D E D I C A T E D O U T S I D E A I R S Y S T E M

Tulsa, OK Longview, TX

The ultimate fresh air solution.

PINNACLE SERIES DEDICATED OUTDOOR AIR SYSTEM ENERGY EFFICIENT DEHUMIDIFICATION

Cultivator & Hybrid Cultivator

RT-OA TM Rooftop Outdoor-Air (DOAS)

Rooftop Ventilator. Models RV and RVE. with Packaged Cooling & Heating

EP SERIES PACKAGED ENERGY RECOVERY SYSTEM ENERGY EFFICIENT AIR COMFORT

Maverick II Commercial Rooftop Systems 15 to 75 tons

Best Practices for Applied Rooftop ` Systems, Applications and. Jerry Cohen President Jacco & Assoc. Installation

HVAC EQUIPMENT. Exceptional Single Zone Heating and Cooling Solutions. Product Application Guide

Best Practices for Applied Rooftop ` Systems - Application and. Jerry Cohen President Jacco & Assoc. Installation

Energy Recovery with Cooling and Heating Model ERCH

VariCool VAV. (Variable Air Volume) 9 to 70 tons Variable Air Volume Water-Cooled and Chilled Water. Unique Solutions for All-Indoor HVAC Projects

Custom Air Handler Solutions Custom Units to Meet Your Unique Design Needs

Energy Recovery with Cooling and Heating

THE RIGHT SPEC. RIGHT NOW.

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

AHU ENERGY RECOVERY VENTILATORS ERV DEDICATED OUTDOOR AIR SYSTEMS DOAS HEATING, COOLING & DEHUMIDIFICATION AHU

DOAS UNITS. ReznorHVAC.com MAKEUP AND VENTILATION AIR 100% OUTSIDE AIR

RQ SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

Greensource Residential Water Source Heat Pumps. Simply Smart. i Series: SV Model. boschheatingandcooling.com

62DA,DB,DC,DD,DE,DF07-38

Technical Development Program COMMERCIAL HVAC SYSTEMS. Water Source Heat Pump Systems PRESENTED BY: Ray Chow. Sales Engineer

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

EP Model. EP Model Water Source Heat Pump. ½ to 6 Ton

RN SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

HVAC 101. H V A C S y s t e m s

AIR HANDLERS. Central Station (CS3) Roof Mounted (RT) (Modular AL Frame AHU)

Vision and Skyline Semi-custom Air Handlers

Reinventing Energy Efficiency

RN SERIES. Installation, Operation & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

Trane Performance Climate Changer Air Handlers. An air handler for every need.

BOOK 1 OVERVIEW RD2XRT INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

BOOK 1 OVERVIEW RD2XIN INSTALLATION AND OPERATION MANUAL. Table of Contents ABOUT BOOK 1:

Architecture - Engineering - Planning

RQ SERIES. Installation, Operation, & Maintenance. Packaged Rooftop Units, Heat Pumps, & Outdoor Air Handling Units WARNING WARNING

PERFECT SOLUTIONS WATERFURNACE COMMERCIAL PRODUCTS. Water Source/Geothermal Heat Pumps

The ultimate in air handling units: directly and indirectly fired

The ultimate in air handling units: directly and indirectly fired

VCM-X Controller Technical Guide

R7DA Series TECHNICAL SPECIFICATIONS. FEATURES and BENEFITS. 6 and 7 ½ Ton DOAS Packaged Gas/Electric Units

DES CHAMPS PRODUCTS. Specializing in: -- Air-to-Air Energy Recovery -- Conditioning Outdoor Air -- Controlling IAQ -- Indirect Evaporative Cooling

The ultimate in air handling units: directly and indirectly fired

Energy-Efficient Makeup Air Units BY HUGH CROWTHER, P.ENG., MEMBER ASHRAE

2009 IECC Commercial Mechanical Requirements

Multi-Path RTU-TYPE 2

Heat Recovery Units. Heat Recovery 1

Appendix 13. Categories of Cooling and Heating systems

Flexible & Innovative. Cooling Solutions

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

SECTION (15733) - DEDICATED OUTDOOR AIR UNITS

Pharmaceutical Facility Design

Commercial Packaged Rooftop Systems

SB Series. Installation, Operation & Maintenance. Vertical Self-Contained Units WARNING WARNING

Dehumidifying with Dedicated Outdoor Air

Product Data. 75 to 150 Nominal Tons

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

NC NC Series. NG Series. Seresco s NG Series Fluid Coolers & NC Series Outdoor Condensers Quiet, efficient reliable heat rejection

CHAPTER 4. HVAC DELIVERY SYSTEMS

Heat pump and energy recovery systems

FORM EG2 (502) FlexSys Configured Packaged Rooftop Air Conditioning Units

FAST AND ROBUST BUILDING SIMULATION SOFTWARE. Chilled Beam Performance: 1 Shelly Street, Sydney

Direct Gas-Fired Make-Up Air Models DG and DGX

Water Source / Geothermal Heat Pumps & Air Conditioners

C13-Series Engineering Guide

Trane Performance Climate Changer Air Handlers. An air handler for every need.

VariCool VAV Engineering Guide

Mission Critical. Series 6, 8 & 9. vertical floor mount Ton Units. Air Conditioning Systems

VariCool EZ-Fit 12 to 70 Tons Variable Air Volume Water-Cooled Water Source Heat Pump Chilled Water

ENGINEERING. Edition No. 13 October 2002

Air Handling Units. Ranging from 15 to 2,000+ tons and 500 to 400,000+ CFM

T-CLASS Commercial Split Systems Up to 20-Ton TSA/TPA Models

The ultimate in air handling units: directly and indirectly fired

Seresco Indoor Pool Dehumidifiers. Unrivaled Performance, Reliability and Value

Greensource Residential Geothermal Heat Pumps. Simply Smart. CDi Series: SM Model. boschheatingandcooling.com

Manufacturer Update 2014 IGSHPA

Transcription:

Heat Pumps M2 SERIES Modular Self-Contained Unit Water-Source Heat Pumps (3-70 tons) Features: Water-source and geothermal heat pump self-contained units with capacities from 3-70 tons 10%-100% variable capacity R-410A scroll compressors for load matching cooling and heating with improved part load efficiency Double wall rigid polyurethane foam injected panel construction reduces air leakage and dampens resonated sound Modulating hot gas reheat humidity control Backward curved plenum supply fans Power return, power exhaust, and energy recovery wheel configurations Service access doors with removable pin hinges and lockable handles Factory installed gas, electric, hot water, or steam emergency heating Labeled components for quick and easy installation Makeup Air Applications Up to 100% Outside Air Dehumidification and Premium Filtration Capabilities A Wide Variety of Factory Installed Features Comfort or Process Heating and Cooling

WSHP M2 series AAON M2 Series water-source heat pump self-contained units provide an ideal solution for new and replacement applications with its modular construction and premier factory installed features. Features such as variable capacity scroll compressors, direct drive backward curved plenum supply fans, head pressure control water valves, and double wall rigid polyurethane foam insulated cabinet construction provide the M2 Series WSHP with unmatched performance. Superior Features Double wall rigid polyurethane foam injected panel construction with thermal break reduces air leakage, dampens resonated sounds, increases thermal resistance, and offers a cleanable air tunnel ideal for demanding indoor air quality applications. Backward curved plenum supply fans are quieter, more energy efficient, and handle higher static pressure applications than forward curved supply fans. Units can be shipped factory assembled or shipped as individual modules to meet the installation demands of any application. Sloped stainless steel drain pans eliminate standing water which can support microbial growth and prevents corrosion and rust that can lead to water leaks and contaminants in the air stream. Removable pin hinges, lockable zinc cast handles, and slide out access to coils and energy recovery wheels provide easy access for maintenance and cleaning when required. Multiple base heights are available that allow ease of installation and can eliminate the need for a housekeeping pad for condensate drain trap. Labeled electrical components and color-coded wiring match the unit specific color-coded wiring diagram that is laminated and permanently affixed inside the control compartment. Factory run test report, wiring diagram, and Installation, Operation, and Maintenance manual with startup form are provided in the control compartment of every unit. Water-source or geothermal heat pump configurations with 10-100% variable capacity compressors for a packaged indoor system with energy efficient heating and cooling. H Backward curved fans are quiet, energy efficient and have high static pressure capabilities. L W The M2 Series Heat Pump can be configured for a variety of applications including: Total Energy Recovery with 100% Outside Air Dehumidification with modulating hot gas reheat and return air bypass Comfort or Process Heating and Cooling Premium High Efficiency Filtration for Indoor Air Quality Modular construction for renovation installations with restricted install space

Premier Options Available for Constant Volume, Variable Air Volume (VAV), Single Zone VAV, and Makeup Air applications with up to 100% outside air. Factory installed total or sensible AAONAIRE energy recovery wheels save heating and cooling dollars by pre-cooling, dehumidifying, pre-heating and humidifying the ventilation outside air (depending on ambient conditions). Up to 80% of the exhaust air energy can be recovered by the wheel. Modulating Hot Gas Reheat for precise humidity control necessary to maintain occupant comfort without the temperature swings common with on/off reheat systems. Modulating gas heat with 5:1 turndown natural gas or 3:1 turndown LP gas applications with open or separated combustion. SCR (Silicon Controlled Rectifier) electric heat control for reduced power consumption, longer heater life, and improved occupant comfort. Multiple high efficiency filtration options with up to MERV 14 efficiency rating are available with or without monitoring devices. Multiple corrosion protection options including 6,000 hour salt spray tested polymer e-coated indoor coils, CuNi coaxial or SMO 254 brazed plate refrigerant-to-water heat exchangers, and 2,500 hour salt spray tested interior and exterior corrosion cabinet protection. ECM (Electronically Commutated Motor) driven or VFD controlled backward curved plenum supply fans for precise air flow control and reduced power consumption. Head pressure control with 2 or 3-way water valve allows for variable flow condenser water operation and operation with lower condenser water temperature. M2 Series Water-Source Heat Pump Unit Dimensions M2 Model Face Area (ft 2 ) Nominal Air Flow (cfm) 005 2,000 008 3,000 011 014 018 022 018 022 026 4,000 5,500 7,500 9,500 7,500 9,500 11,000 M2 WSHP Capacity (tons) 03 04 05 06 07 08 10 11 13 15 16 18 20 25 30 Compressors/ Circuits Refrigerant-to-Water Heat Exchanger Width (in) 1/1 50 2/2 Coaxial Brazed Plate 62 84 Height Single Level (in) Height Dual Level* (in) 32 66 44 90 48 54 48 54 48 54 64 98 110 98 110 98 110 130 Length (in) Length varies depending on options selected 026 032 11,000 14,000 40 84 96 64 70 130 142 026 032 036 11,000 14,000 16,000 50 4/2 84 96 64 70 130 142 032 036 14,000 16,000 60 70 96 70 142 * Unit with energy recovery wheels will always be dual level

M2 Water-Source Heat Pump Series Features Energy Recovery Wheel AAONAIRE energy recovery wheel is capable of transferring sensible and latent energy from the incoming air stream to the exhaust and preconditioning the supply air. This saves energy by reducing mechanical heating and cooling use, and also lowers costs by increasing effective system capacity by 30% or more which allows smaller equipment to be selected. Energy recovery wheels are also available as sensible only and with mechanical purge that reduces carryover to less than 1%. Modulating Hot Gas Reheat This system delivers only the amount of reheat required for space comfort, providing precise dehumidification without overcooling the space. Occupant comfort is uniform and consistent; drastic temperature swings common to on/off type reheat systems are eliminated. Head Pressure Control Modulating head pressure control, via either 2- or 3-way modulating water valve, allows unit operation below 65 F condenser water temperature. This gives the unit a larger operating range, which is especially beneficial in the dehumidification mode of operation. Variable Capacity Scroll Compressors Variable capacity scroll compressors can modulate from 10-100% capacity. This allows the system to maintain consistent supply air temperatures at all operating conditions. During part load operation, reducing compressor capacity increases part load efficiency and ultimately saves valuable system operating costs. Geothermal/Water-Source Heat Pump An M2 Series water-source/geothermal heat pump unit can heat the air as energy efficiently as it cools it. By transferring heat from the earth to the building, the M2 Series heat pump requires no fossil fuels. Polymer E-Coated Coils A uniformly thick polymer coating is applied to the entire coil by an immersion process that minimizes the potential for gaps in coverage that may occur with spray coating. The polymer coil coating provides corrosion protection for more than 6,000 hours in salt spray testing, while maintaining the thermal performance of the coil. Double wall rigid polyurethane foam panel construction increases thermal resistance, reduces air leakage and attenuates radiated noise. Available Modules Fan Module Filter Module Mixing Box Module Heating Module Cooling Module Blank Module Controls Module Energy Recovery Module Water-Source Heat Pump Module PARTS LI M IT E D W A R R A N T Y

Factory Installed Receiver M2 Series Reversing Valve for Heat Pump Operation Brazed Plate Refrigerant-to-Water Heat Exchanger Variable Capacity Scroll Compressor 10-100% for Load Matching WSHP with Modulating Hot Gas Reheat Piping Layout 2-Way Head Pressure Control for Lower Water Temperatures and Variable Water Pump Energy Savings Modulating Hot Gas Reheat for Humidity Control 30 ton WSHP Module Interior

M2 Water-Source Heat Pump Typical Configurations M2 Series AAON M2 Series WSHP Modules provide design flexibilty and ease to meet job application requirements. Return Air Water-Source Heat Pump with Modulating Hot Gas Reheat Outside Air Return Air Water-Source Heat Pump with Economizer Exhaust Air Outside Air Return Air Water-Source Heat Pump with Return Fan Return Air Water-Source Heat Pump with Cartridge Filter and Face and Bypass Coil

Exhaust Air Return Air Outside Air Energy Recovery Unit with Water-Source Heat Pump and Modulating Hot Gas Reheat Exhaust Air Return Air Outside Air Energy Recovery Unit with Water-Source Heat Pump and Economizer Return Air Exhaust Air Outside Air Energy Recovery Unit with Water-Source Heat Pump, Economizer, and Electric Heat

M2 Series M2 Series Water-Source Heat Pump for Schools A school heating and cooling system needs to provide ventilation air, be energy efficient, and handle varying sensible and latent loads without temperature and humidity swings. M2 Series WSHP with Energy Recovery for School Application This M2 Water-Source Heat Pump includes an energy recovery wheel that is sized to handle 100% outside air. The energy recovery wheel enhances indoor air quality by allowing larger amounts of outside air to be provided to the space and through improved humidity control. The energy recovery wheel also provides energy savings by recycling energy instead of losing energy through the exhaust air stream. Combining the efficiency of the energy recovery wheel with the efficiency of a water-source heat pump system can save schools money in operating costs. M2 Series Water-Source Heat Pump with Energy Recovery

M2 Series The AAON M2 Series WSHP provides several high efficiency options: Energy Recovery Wheel, Economizer, Direct Drive Backward Inclined Fans, Digital Compressors, and Modulating Electric Heat. Full Modulating Outside Air Damper 2 Postion Exhaust Damper Remote Water-Source Heat Pump Module Fully Modulating Return Air Damper M2 Series WSHP with Economizer & Energy Recovery with Remote WSHP module for School Application Variable capacity compressors combined with modulating hot gas reheat, provide tight control of the space temperature and humidity, keeping the teachers and the students comfortable and focused on learning. Variable capacity compressors are capable of modulating the cooling and heating capacity from 10-100%. This M2 Water-Source Heat Pump unit takes efficiency one step further by providing an economizer mixing box. The economizer includes dampers and control logic designed to determine when to use outside air for cooling or heating instead of mechanical cooling or heating. Two additional items that make this unit unique are the remote mounted WSHP section for installation flexibility, and a hot water coil for emergency heat. AAON Energy Recovery Wheel M2 Series 12 cartridge filter module with up to MERV 14 air quality. Pre-filters can be selected to protect the cartridge filter.

M2 Series M2 Series Water-Source Heat Pump for Office Buildings An office building needs precise space temperature and humidity controls that can be individually controlled for different rooms within the building. M2 Series Single Zone VAV WSHP for Office Application This AAON single zone VAV unit includes a variable speed direct drive ECM fan to modulate the air flow based on space temperature, and a 10-100% variable capacity compressor to modulate capacity based on the supply air temperature. The unit also includes a 2-way modulating water valve that stabilizes the head pressure over a range of condenser water temperatures and saves water pump energy by allowing the use of a variable flow pump in the water loop. M2 Series Single Zone VAV Water-Source Heat Pump

M2 Series The AAON M2 Series WSHP Modules provide design flexibility and easy to meet job application requirements. M2 Series WSHP Module Flexibility This AAON unit shows the flexibility of the M2 series. The modules can be arranged to fit a specific application. This unit allows for a smaller footprint by stacking the watersource module on the top level. When the unit ships assembled from the factory, all refrigerant piping is done internal to the unit so no refigerant piping is necessary in the field, only water piping. M2 Series with WSHP Module on the Top Level and AHU Modules on the Bottom Level

AAON Environmentally Friendly HVAC Product Family ROOFTOP UNITS RZ/RL SERIES RN SERIES RQ SERIES OUTDOOR AIR HANDLING UNITS CONDENSING UNITS CB SERIES PACKAGED OUTDOOR MECHANICAL ROOMS SELF-CONTAINED UNITS SB SERIES RN SERIES RZ/RL SERIES CF SERIES BOILER MECHANICAL ROOM LF SERIES LN SERIES RQ SERIES CN SERIES SA SERIES COILS FLUID COOLER LZ SERIES BOOSTER, HYDRONIC, & DX CL SERIES INDOOR AIR HANDLING UNITS M2 SERIES WATER-SOURCE HEAT PUMPS F1 SERIES V3 SERIES RQ SERIES H3 SERIES RZ/RL SERIES RN SERIES SA SERIES M2 SERIES M3 SERIES VERTICAL & HORIZONTAL WSHP M2 SERIES SA SERIES SB SERIES 2425 S. Yukon Ave. Tulsa, OK 74107-2728 www.aaon.com It is the intent of AAON to provide accurate and current product information. However, in the interest of product improvement, AAON reserves the right to change pricing, specifications, and/or design of its product without notice, obligation, or liability. Copyright AAON, all rights reserved throughout the world. AAON and AAONAIRE are registered trademarks of AAON, Inc., Tulsa, OK. WSHP_M2 V84240 161011