Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

Similar documents
YCAL-SB Millennium AIR COOLED LIQUID CHILLER R407C REFRIGERANT. COOLING CAPACITIES 141 kw to 360 kw

AVAILABLE MODELS, NOMINAL CAPACITIES TABLE 1 and SOUND PRESSURE LEVELS. Optional acoustic component enclosure and two speed fans

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

PRODUCT GUIDE

Optimised for high ambient operation (up to 55 C ambient) EWAD-MZ. Air cooled chiller

EASY_R R407C. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans. 5,2 41,5 kw T_ESY_R_0508_GB

.2 Section Waste Management and Disposal.

Call us today! (800)

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

HYDRONIC RESIDENTIAL

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

CMA TECHNICAL MANUAL CONDENSING UNITS FOR OUTDOOR INSTALLATION O L S A F RA N

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

30GN FLOTRONIC II AIR-COOLED CHILLERS

i-chiller 181 to 210 kw ic770 to ic780 ABOUT THE i-chiller RANGE RELIABILITY: ENERGY & PROCESS EFFICIENCY: EASE OF OPERATION & MAINTENANCE:

Call us today! (800)

Call us today! (800)

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

30GT FLOTRONIC AIR-COOLED CHILLERS

CHAPTER 6 CONDENSING UNITS

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

EWAD-TZB. Screw inverter chiller. High efficiency chiller for comfort and process cooling

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

Be sustainable while protecting your business

EWAD-TZ. Air cooled chiller with R-134a inverter driven screw compressor

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

AIR-COOLED LIQUID CHILLER FOR OUTSIDE INSTALLATION FROM 4,3 TO 35,1 kw

30HXC Nominal cooling capacity kw

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

Modular Air-cooled Chillers

All series is using Hitachi scroll compressor, low vibration and high efficiency. Internal thermostat embedded compressors, and it can react quickly.

500 EX Fusion Compressor Series

LZT High efficiency air to water heat pumps with E.V.I. compressors

OACS Outdoor Air-Cooled Central Chillers

Chapter-8 Capacity Control of Refrigeration Systems

COMMECH SERIES AIR CONDITIONING CSH SEMI-HERMETIC SCREW PACKAGES. ORIGINAL MANUFACTURED EQUIPMENT Commech Series New Models BA AUS

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

KELVIN Clim F497. Kelvin air conditioning

Leadership, Innovation, Advanced Technology Synergise Here!

EKS/HE. MultiScroll Air-cooled liquid chillers High efficiency. Solution B - Base I - Integrata

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

Water-cooled chillers with High Speed Centrifugal Compressors

Kelvin air conditioning. KELVIN Clim W280. Cooling Capacity: 280 ~ 1840 kw

SCROLL COMPRESSORS TYPE AIR COOLED PACKAGE CHILLERS

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

CZT CZT. High efficiency air to water heat pumps with E.V.I. compressors E.V.I. HP OTHER VERSIONS ACCESSORIES

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

MECHANICAL SERVICES 101. Ian White

Air cooled industrial chillers

Epsilon Echos kw. General information Air-Water unit with scroll compressors driven by DC inverter. Unique selling points

30GX 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

Sintesis Advantage Air-cooled chillers

Neosys Product catalogue

As a standard, heat exchangers are provided with flange water connections (BS Standard Table E). All evaporator are supplied fully insulated.

BETA ECHOS. Air/water cooled chillers and heat pumps kw. General BETA ECHOS is a range of chillers and ductable air-water heat pumps.

Aquaflair TRAC-TRAF-TRAH

Air-cooled chillers with single-screw compressor. Installation, operation and maintenance manual D - KIMAC EN. Original Instructions

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

CZT CZT E.V.I. High efficiency air to water heat pumps with E.V.I. compressors OTHER VERSIONS ACCESSORIES

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

kw. technicalcatalogue

Air Cooled Chillers & Heat Pumps FullPower HE-A

GLIDER EVO FREE GLIDER EVO FREE GLYCOL FREECOOLING. rcgroupairconditioning

Kälte Klima. Air cooled liquid chiller Free-Cooling from 45 kw to 385 kw. Scroll Compressors SCAEY-FC DE 98

YCWL0240SE-YCWL0395SE & YCWL / YCRL0200HE-YCWL / YCRL0610HE. Revision 2 Form EG2 (0709)

44,9 202,0 kw. technicalcatalogue

30XAS Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features and advantages. Very economical operation

Chillers EWAQ-E-/F- EWYQ-F- Air cooled multi-scroll chillers and heat pumps

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

30RBM/30RBP AIR-COOLED SCROLL CHILLERS WITH GREENSPEED INTELLIGENCE PRODUCT SELECTION DATA

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design

Kälte Klima. Air cooled water chillers air cooled reversible heat pumps from 45 kw to 320 KW. Compressors Scroll SCAEY DE 88 04/11 12/10

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1

Liebert CSU3000 Chiller

Water-cooled chillers Remote condenser chillers NEW

Chillers, air and water cooled, featuring centrifugal compressors with magnetic levitation, from 200 to kw

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

Installation Operation Maintenance

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

Air Cooled Chillers & Heat Pumps WinPACK HE-A

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

EWWD MBYN EWLD MBYN Applied systems

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

AQUACIAT. Water chillers. Free cooling modules for AQUACIAT2 700V to 1100V AQUACIAT POWER 1200V to 1800V USE RANGE FREE COOLING

60Hz. R134a HXWC SERIES. 205 to 560 Tons. Products That Perform...By People Who Care WATER-COOLED SEMI-HERMETIC SCREW COMPRESSOR WATER CHILLERS

water-cooled CHILLERS

Rotary Screw Compressors. ASK Series With the world-renowned SIGMA PROFILE Flow rate 0.79 to 4.65 m³/min, Pressure 5.5 to 15 bar.

SyScroll 40 to 75 Air NEW

Transcription:

Air-Cooled Variable Speed Drive Screw Chillers Super Efficient Super Quiet Cooling Capacity Range 540-1405 kw R134a

World s first low sound Air-Cooled variable speed drive screw chiller The recognition for energy efficient chillers is more apparent now than ever before. YORK has more than 25 years experience in the development of inverter driven large capacity water-cooled chillers. We now proudly introduce Symphony the Worlds first low sound Air-Cooled variable speed drive screw chiller. Symphony chillers are finely tuned to provide features of ultimate importance: Flexible model range and options to suite your requirements. Highest operating efficiency at all conditions. Sound reduction options to suit most environments. Designed with built-in reliability. Low maintenance costs. Low installation costs. Economical operating costs. Fuzzy Logic control. Flexible Model Range Four levels of operating efficiency: Standard. Standard with optimised ESEER. High Efficiency. High Efficiency with optimised ESEER.

Refrigerant Flow Diagram Low-pressure liquid refrigerant enters the cooler tubes and is evaporated and superheated by the heat energy absorbed from the chilled water passing through the cooler shell. Low-pressure vapour enters the compressor where pressure and superheat are increased. Highpressure vapour is passed through the oil separator where oil is removed, from the refrigerant, and recirculated to the compressor via the oil cooler. High-pressure oil-free vapour is fed to the aircooled condenser coil where heat is rejected to the air that is forced across the coil surface by fans. The fully condensed liquid refrigerant enters the feed stepper motor valve that controls the liquid flow to maintain a constant liquid level in the Flash Tank. The drain stepper motor valve functions as an Electronic Expansion Valve and controls the compressor suction superheat. The Economiser Solenoid Valve controls a medium pressure vapour feed to the compressor economiser port. When the valve is open refrigerant vapour flashes off, in the flash tank, to provide additional subcooling to the liquid in the tank. The subcooled liquid is then fed to the evaporator. Increasing both the subcooling and the superheat therefore enhances the cooling capacity. CONDENSER REFRIGERANT OIL GLYCOL OIL SEPARATOR FEED VALVE FLASH TANK DRAIN VALVE LEVEL SENSOR GLYCOL PUMP CONTROL PANEL/VSD EVAPORATOR ECONOMIZER SOLENOID VALVE COMPRESSOR

Highest Operating Efficiency at all Conditions Provides Low Operating Costs Symphony has been designed to provide high operating efficiencies at all conditions. The incorporation of variable speed compressor technology, electronic expansion valves and optimised part load control results in class A full load Energy Efficiency Ratios (EER) as high as 3.2 and European Seasonal Energy Efficiency Ratios (ESEER) that exceed 4.0. These high efficiencies together with high 0.95 power factor at all operating conditions, result in economical operating costs. Optimised European Seasonal Efficiency (ESEER) Control Smart Anticipatory Control determines how many compressors need to start to satisfy the current cooling load. It keeps as many compressors possible on line, and reduces the speed, in an effort to optimise the use of the entire evaporator tube surface to ensure optimum efficiency at all conditions. 5.0 0 CHILLER EFFICIENCY Chiller Efficiency 1.00 Energy Efficiency Ratio EER kw/kw 4.0 0 3.0 0 2.0 0 Ambient C 2 0 2 5 3 0 3 5 % Capacity 25 50 75 100 Power Factor 0.95 0.90 0.85 0.80 0.75 0.70 0.65 0.60 Symphony Chiller Ordinary A/C Screw Chiller 0 10 20 30 40 50 60 70 80 90 100 Chiller Load % Conventional Screw Chiller Symphony

Increased Reliability and Low Maintenance Costs The heart of the Symphony chiller is the YORK MTS semi-hermetic screw compressor. The following design features provide increased reliability and low maintenance costs: Each compressor motor has a dedicated inverter, to match motor speed to cooling demand; there is no slide valve, return spring or control solenoid. Therefore this simple dual screw rotor compressor has 50% less moving parts than conventional screw compressors. Symphony controls monitor compressor runtime and start-ups and automatically switch the lead and lag compressors to balance operating hours. The soft start characteristics of variable speed drive, the starting current never exceeds full load amps, eliminates any compressor starting stress. Another advantage, of low starting current, is that standby generators are smaller than those required for conventional screw chillers. % Full-Load Amps 600 500 400 Solid State Starter 300 Star Delta Starter 200 100 Symphony Chiller 0 Time Sound Reduction Options to suit most Environments Each efficiency level has a selection of three acoustic options: Standard sound level Generally applicable for daytime operation in city centres etc. Reduced sound level For daytime operation where background noise is lower. Low sound level For night and day operation near residential areas etc. Sound Pressure db(a) Distance 10 metres 7 5 7 3 7 1 6 9 6 7 6 5 6 3 6 1 5 9 5 7 5 5 SYMPHONY SOUND OPTIONS 5 0 0 6 0 0 7 0 0 8 0 0 9 0 0 1 0 0 0 1 1 0 0 1 2 0 0 1 3 0 0 Chiller Cooling Capacity kw Standard Chiller Reduced Sound Chiller Low Sound Chiller

Technical data Standard Efficiency Model YCIV-SE-RS 0600 0650 0720 0770 0840 0920 1000 1070 1180 1340 1500 Cooling Capacity kw (1) 562 620 678 727 793 870 949 994 1104 1251 1405 Energy Efficiency Ratio (EER) 2.93 2.94 2.98 2.94 3.02 3.02 3.03 2.97 2.98 2.99 3.00 Energy Class B B B B B B B B B B B ESEER (2) 4.03 4.01 4.05 4.01 4.05 4.09 4.14 4.08 4.09 4.12 4.19 Sound Pressure at 10 Metres db(a) 65 65 66 65 68 67 67 69 70 71 72 Standard Efficiency Low Sound Model YCIV-SE-LS 0600 0650 0720 0770 0840 0920 1000 1070 1180 1340 1500 Cooling Capacity kw (1) 547 604 660 708 772 848 914 968 1075 1217 1368 Energy Efficiency Ratio (EER) 2.72 2.72 2.76 2.72 2.80 2.80 2.81 2.75 2.76 2.77 2.78 Energy Class C C C C C C C C C C C ESEER (2) 4.07 4.05 4.10 4.05 4.09 4.14 4.18 4.12 4.13 4.16 4.24 Sound Pressure at 10 Metres db(a) 58 57 59 58 60 60 60 60 61 64 64 High Efficiency Model YCIV-HE-RS 0590 0630 0700 0760 0800 0830 0930 1050 1120 1220 1380 Cooling Capacity kw (1) 556 595 661 714 760 791 876 983 1047 1139 1289 Energy Efficiency Ratio (EER) 3.16 3.17 3.16 3.13 3.18 3.21 3.13 3.14 3.14 3.14 3.14 Energy Class A A A A A A A A A A A ESEER (2) 4.07 4.10 4.09 4.07 4.07 4.09 4.11 4.14 4.14 4.14 4.19 Sound Pressure at 10 Metres db(a) 63 64 64 66 66 68 67 67 68 69 70 High Efficiency Low Sound Model YCIV-HE-LS 0590 0630 0700 0760 0800 0830 0930 1050 1120 1220 1380 Cooling Capacity kw (1) 541 579 643 695 740 770 853 957 1019 1109 1255 Energy Efficiency Ratio (EER) 2.94 2.95 2.94 2.91 2.96 2.99 2.90 2.92 2.92 2.92 2.91 Energy Class B B B B B B B B B B B ESEER (2) 4.11 4.14 4.13 4.11 4.11 4.13 4.16 4.18 4.18 4.19 4.24 Sound Pressure at 10 Metres db(a) 57 58 57 58 58 60 60 59 60 61 61 (1) At 7 C leaving chilled water and 35 C ambient. (2) ESEER = European Seasonal Energy Efficiency Ratio Accessories The following accessory options can be provided: High Static Fans: Providing 100 pa external static pressure Condenser Coil Fins: plain aluminium or copper, epoxy pre-coated aluminium or the whole aluminium finned coil can be epoxy dipped and cured. Unit Protective Panels: heavy gauge wire mesh or painted steel louvres. Pressure Relief Service Valve Kit Evaporator water connections: field fit victaulic flange kits can be provided. Liquid Flow Detection: switch or differential pressure switch. Building Automation System Interface: Leaving chilled water reset and electrical current limiting. Vibration Isolation: Neoprene pads, spring isolators or seismic spring isolators. www.johnsoncontrols.com Manufacturer reserved the rights to change specifications without prior notice