Control Panels Variable Frequency Drives Float Switches Alarm Systems For Water/Wastewater Pump and Motor Control. Visit worldwide link at

Similar documents
Visit worldwide link at

International Catalog

QUICK SHIP Products. Available for Same/Next Day Shipment at NO ADDITIONAL CHARGE!

product brochure Sump, Effluent and Sewage Controls

PRODUCT PRICE BOOK September 4, 2018

PRODUCT PRICE BOOK January 1, 2019

PRODUCT PRICE BOOK JUNE 4, 2018

2 SJE-Rhombus...The Name You Trust Above: Simplex - Below: Duplex Above: Simplex - Below: Duplex

Control Panel with Across The Line Starters

To Purchase This Item, Visit BMI Gaming (800) Super Scooper OPERATION MANUAL

TECHNICAL BROCHURE BCALARM R4. Indoor and Outdoor Panels and Accessories

Taking a Temperature

VACUUM PUMP Model VCP-8101

Specification Document. Single-circuit Embedded Water Leakage Detector AD-AS-1BM (RoHS-directive-compatible)

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

PUMP / CONTROL PANEL SWITCHES TECHNICAL BROCHURE BCPFS R10

We ve Got Panels Under Control.

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23

FOCAS ppm Bilge Alarm. Product Specifications Rev.1.03 (T)

Variable Frequency Drive SERIES MP800 VFD

Soft Start Series MP700 Solid State, Reduced Voltage

Across-the-Line SERIES MP300 Combined Manual and Automatic

Wilo CO-Helix Booster Systems. Product Presentation July, 2017

PRODUCT NAME. Thermo-dryer MODEL. Original Instructions IDH4-10, IDH4-20, IDHA4-23 IDH6-10, IDH6-20, IDHA6-23

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

Custom Pump Controls. The Custom Controls Solution Provider. A New Generation. Complete Management. Page 2

LC150 VIEW-AT-A-GLANCE PUMP CONTROL-TELEMETRY UNIT

Liquid Level Alarms & Controls

Safety Precautions 安全上の注意

Refrigerated Air Dryer

Refrigerated Air Dryer

SAMPLE MANUAL - INSTALLATION - FOR REFERENCE ONLY. ChemScan mini Analyzer. Parameter. Method #### Installation, Operation & Maintenance Manual

FTA550 JOCKEY PUMP CONTROLLERS

IDX-OM-H006-I Initial issue: January th edition : November Operation Manual. Refrigerated Air Dryer. Series

GRUNDFOS SEWAGE & EFFLUENT PUMP ACCESSORIES

MYRIAD TRIPLEX PUMP CONTROLLER INSTRUCTION MANUAL

SLATE. Base Module INSTALLATION INSTRUCTIONS R8001A1001

MYRIAD DPC DUPLEX PUMP CONTROLLER INSTRUCTION MANUAL VERSION 3.7

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

Operation Manual. Original Instructions PRODUCT NAME. Refrigerated Air Dryer. MODEL / Series

Two-Channel Gas Controller

Tri-Stack Smart System

SJE-Rhombus Type IFS w/c-level Sensor Installation Instructions and Operation/Troubleshooting Manual

The LC-100 s valved manifold controls the flow of air and allows the LC-100 to accurately monitor liquid levels with a minimal air usage.

Enclosed Scroll Air Compressor System SES 3-5 HP

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

This manual explains the features and operations of the VFDC controller which is specifically designed for Pressure Booster Pump Systems.

SCC Inc. Master Panel. Specifications. Document No. TS 2010 February 11, Product Description. Sample Specification

PRODUCT PRICE BOOK Pricing Effective February 4, We ve Got Panels Under Control.

Operation Manual. Programmable Logic Controller

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

Lift Station Level Controller

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

TS Series. Technical Instructions. Document No. TS-4000 June 25, TS-CE Combustion Enclosures with LMV5. Description

Oxygen (O2) Single-Point Gas Detection System

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

AS950 REFRIGERATED SAMPLERS

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

FUEL OIL DAY TANKS. SST Level Controller: UL 508 LISTED

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

SCC Inc. TS Series. Technical Instructions. Document No. TS 5000 February 12, TS CE Combustion Enclosures with LMV3.

EG Controls. SLIMVIEW 120 VOLT FLOAT SERIES DUPLEX PUMP CONTROL PANEL SPECIFICATION for CITY OF E G

SECTION DOMESTIC WATER PRESSURE BOOSTING SYSTEMS (VFD) PART 1 - GENERAL 1.1 SUMMARY

Lift Station Monitoring & Control The process begins here

GASGUARDIAN Channel Controller OPERATING & INSTALLATION MANUAL

Refrigerated Air Dryer

Drawing Submittal Package

Alarm Systems Alarm Bot CS2004E CS CS CS H2Oil Alarm System...12

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

Electro-Sentry. Users Manual

SECTION PACKAGED HEAT TRANSFER SYSTEM

Accuracy by Design Products for the HVAC Professional

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

ANCHOR BOLT DETAIL. Non-Shrink Grout. Poured In Place, After Equipment Setting. "L" Type Anchor Bolt Carbon Steel AISI 304 S.S.

K-Controller Brochure.qxp_ Controller Brochure 2/27/17 3:03 PM Page 4 Versa IC Platform

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Surface Mount Type. Outline Dimensions 外形寸法図. Surface Mount Type LED

FTA550F JOCKEY PUMP CONTROLLERS STANDARD SUBMITTAL PACKAGE

When reliability is vital. Alemite Carbon Shield TM Systems deliver

Harrier + Smart Controller & Chemical Management System

Refrigeration Controller Operator s Manual (HRC) PO Box 6183 Kennewick, WA

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

wireless. web-based. worthy of the name RACO.

TOTAL SOLUTIONS. Liquid Level Control Product Guide. MATELEC AUSTRALIA innovative by design

GasScanner 4C. Four Channel Monitor. Operator s Manual. MINT-0280-XX Rev. A 02/25/08

Model 7700 Pump Director Valve and Pump Motor Interface Controller

Drawing Submittal Package

Beacon 200 Gas Monitor Operator s Manual. Part Number: RK Released: 6/6/08

LC1350 Level Controller

Operational Overview and Controls Guide

isopv and AGH-PV Ground Fault Detector for Ungrounded Solar Arrays up to 1100 V And Isolation Tester Prior to Array Startup (Grounded and Ungrounded)

SIMPLEX WEATHERPROOF CONTROL PANELS

2018 PRICING. alderonind.com STANDARD PRODUCTS

Series 5000 Hydrazine Analyzer Model 60002

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

900MAX PORTABLE SAMPLERS

Transcription:

Control Panels Variable Frequency Drives Float Switches Alarm Systems For Water/Wastewater Pump and Motor Control Visit worldwide link at www.sjerhombus.com 22650 County Highway 6 PO Box 1708 Detroit Lakes, MN 56502 USA Phone: +1-218-847-1317 Fax: +1-218-847-4617 Email: customer.service@sjeinc.com

VARIOSPEED VFD SERIES The VARIOspeed family of VFD (Variable Frequency Drive) products are an economical, highly reliable, pre-engineered variable speed option for constant pressure control applications, including booster pump, deep well submersible pump and irrigation pump applications. Parameters are factory-programmed for easy installation and setup. PID Control Simple and user friendly interface Low pressure alarm (pipe burst or run dry protection) High pressure protection System fault log Adjustable electronic overload Auto Start on pressure drop (adjustable) Auto Stop on low HZ (no-flow-sleep mode) saves energy and protects the pump Lag pump control Hand/Off/Automatic switches for manual or automation pump operation 0-200 PSI transducer (4-20 ma signal) Five-year limited warranty on panel One-year limited warranty on transducer VARIOspeed ECONO Indoor (NEMA1) applications 1.5 HP (7.0 amps), 3.0 HP (10 amps) Single phase input voltage, three phase output voltage UL/cUL Listed enclosure and VFD VARIOspeed N1/3R Indoor (NEMA1) and indoor/outdoor (NEMA 3R) applications 1.5 HP - 20 HP (7-58 amps) Single phase or three phase input voltage, three phase output voltage VARIOspeed 3R Duplex Indoor/outdoor (NEMA 3R) applications 1.5 HP - 20 HP (208-240V) 7.5 HP - 20 HP (480V) Single phase or three phase input voltage, three phase output voltage Includes pump circuit breaker (240V) or pump fuses (480V), fan and thermostat 2

VARIOSPEED VFD SERIES VARIOSPEED USER INTERFACE (ECONO, N1, 3R) Run Indicator LED Fault Indicator LED Display: system status, current pressure, set pressure, motor current and output frequency Escape Button Rotary/Push Button for Menu Auto/Off Selector Switch Left Arrow Button VARIOSPEED USER INTERFACE (3R DUPLEX) Pump Run Indicators LED Fault Indicator LED Display: 4 line/20 character back-lit LCD display is easy to read Escape Button Rotary/Push Button for Menu Left Arrow Button 3

14:33 14:32 PIDval2 61.7PSI Hz Out 57.63Hz 0.00Hz I Out 0.00A STF FWD STOP EXT PREV SET NEXT VARIOspeed LCD HAND OFF AUTO Risk of injury and electric shock WARNING Metal Surface May Get Hot Risk of Burn Read the manual and follow the safety instruction before use. Isolate from supply and wait 10 minutes before removing this cover. Ensure proper earth connection. CAUTION Risk of Fire Mount the Inverter on a non-combustible surface. Il y a un risque de se faire mal et de recevoir une déscharge électrique WARNING Surface de métal peut devenir chaud-risqu de Brûlures Avant de l utiliser il faut lire le manual e il faut suivre les instrictions de sécurité L isoler les matéraux électriques et attendre dix minutes avant d enlever la couverture Assurer la propre connection mise à la terre AVERTISSEMENT Il y a un risque d un feu Montez non-combustible le veriateur de vitesse sur une surface ケガ感電の危険性警告 バーンのリスク - 金属表面は ホットを得ることができます取扱説明書を読み 安全に従ってください使用前に命令電源から切り離し このカバーを取り外す前に10 分待ちます 適切なアース接続を確認してください注意 火災の危険性不燃性の表面上にインバータをマウント ケガ感電の危険性警告 バーンのリスク - 金属表面は ホットを得ることができます 取扱説明書を読み 安全に従ってください使用前に命令電源から切り離し このカバーを取り外す前に10 分待ちます適切なアース接続を確認してください 注意 火災の危険性不燃性の表面上にインバータをマウント PULL 14:33 14:32 PIDval2 61.7PSI Hz Out 57.63Hz 0.00Hz I Out 0.00A STF FWD STOP EXT PREV SET NEXT VARIOspeed LCD HAND OFF AUTO Risk of injury and electric shock WARNING Metal Surface May Get Hot Risk of Burn Read the manual and follow the safety instruction before use. Isolate from supply and wait 10 minutes before removing this cover. Ensure proper earth connection. CAUTION Risk of Fire Mount the Inverter on a non-combustible surface. Il y a un risque de se faire mal et de recevoir une déscharge électrique WARNING Surface de métal peut devenir chaud-risqu de Brûlures Avant de l utiliser il faut lire le manual e il faut suivre les instrictions de sécurité L isoler les matéraux électriques et attendre dix minutes avant d enlever la couverture Assurer la propre connection mise à la terre AVERTISSEMENT Il y a un risque d un feu Montez non-combustible le veriateur de vitesse sur une surface ケガ感電の危険性警告 バーンのリスク - 金属表面は ホットを得ることができます取扱説明書を読み 安全に従ってください使用前に命令電源から切り離し このカバーを取り外す前に10 分待ちます 適切なアース接続を確認してください注意 火災の危険性不燃性の表面上にインバータをマウント ケガ感電の危険性警告 バーンのリスク - 金属表面は ホットを得ることができます 取扱説明書を読み 安全に従ってください使用前に命令電源から切り離し このカバーを取り外す前に10 分待ちます適切なアース接続を確認してください 注意 火災の危険性不燃性の表面上にインバータをマウント PULL VARIOSPEED VFD SERIES VARIOspeed LCD Power Available HP range (208-240V) 5 HP - 40 HP (380-480V) 5 HP - 50 HP Models available for single phase or three phase supply voltage UL Listed for single phase or three phase supply voltage Energy optimization control Control PID control Hand/Off/Auto selector switch Adjustable electronic overload 0-200 PSI transducer (4-20 ma signal) Auto Start on pressure drop (adjustable) Auto Stop on No-flow (sleep mode) Pre-charge control (gradual pipe pressurization) High and low pressure alarms Automatic system restart Low water shutdown digital input 2 relay outputs 2 analog outputs Modbus RTU communication (RS-485) NEMA 1 indoor rated One-year limited warranty Pressure Booster Pump Application Deep Well Submersible Pump Application USER FRIENDLY VARIOSPEED LCD DISPLAY: DISPLAY: Monitor Backlit LCD MENU: Displays parameters and drive data FUNCTION KEYS: Navigate through parameters, monitored data, and save changes SETTING DIAL: Scroll through parameter list and edit parameter value 4

CONSTANT PRESSURE CONTROLS VFDC-4100 Controller 1-4 VFD control Graphic screen display with LED back light System status display: operating pressure, set pressure, time/date, alarm with time/date Pump status display: pumps in use, lead pump, pump run/stop, pump speed, VFD fault, hour meter for each pump 4 arrow buttons for easy navigation and setup Automatic alternation (cycle or timed based) 13 programmable digital outputs Jockey pump operation (smaller lead pump) Password protection High and low pressure alarms Low suction pressure/low level with programmable restart RS-485 Modbus Serial communication VFDC-4100 controller available in customized panel solutions, not sold individually Endura MD Triplex Painted steel, wall mounted single door enclosure; NEMA 1 indoor rated (2) cooling fans with filters and adjustable thermostat VFDC-4100 controller Panel mounted Variable Frequency Drive (VFD) for each pump Circuit breaker disconnect for each pump 22mm Hand/Off/Auto switches for each pump 22mm General Alarm red indicator activates on: Pump fault High pressure fault Low suction pressure fault 24 VDC power supply - NEC Class 2 operating overcurrent protection Multi-tap 150 VA transformer 480/240/208:120 VAC Terminal blocks for: Main power Pumps Pressure transmitter Low suction pressure switch Remote enable Auxiliary alarm contacts 0-200 PSI pressure transmitter with 6m (20ft) cable 5

CUSTOMIZED CONTROLS INDUSTRIAL AND MUNICIPAL Variable Frequency Drives Reduced Voltage Soft Starter (RVSS) Programmable Logic Controllers (PLC) Service entrance rating Manual transfer switch gear SCADA systems Operator interface (HMI) Remote monitoring Telemetry/alarm dialers Multiple pump control User specified components Voltage/current meters Line and load reactors Motor Control Centers (MCC s) VFDC-4100 controllers PUMP WATCH EXPRESS Pump Watch Express is a comprehensive family of 4G LTE/3G compact cellular RTUs and Gateway used for monitoring pumping systems. It offers a simple, effective tool for management of multiple sites, including alarm notification, data logging, and graphic system visualization. FAMILY FEATURES 6 Li-ion backup battery for power loss detection and notification SMS, email, and web portal alarm notifications Graphic HMI with simple and clear station status display View all pumping stations on an interactive map Data logging and historical trending First year of service included Optional: web portal customization Available in NEMA 4X enclosure

STANDARD CONTROL PANELS SJE Rhombus control panels offer pump control and alarm notification in one convenient package for a variety of applications, including pump chambers, sump pump basins, irrigation systems, lift stations and more. Additional models available at www.sjerhombus.com. NEX Series - Single Phase Simplex NEX Series - Single Phase Duplex Controlled by float or pressure switches NEMA 4X (ultraviolet stabilized thermoplastic) Compact and economical design Model 112 - Single Phase Simplex Model 122 - Single Phase Duplex Controlled by float or pressure switches NEMA 4X weatherproof thermoplastic enclosure High level alarm beacon and horn Model 312 - Three Phase Simplex Model 322 - Three Phase Duplex Controlled by float or pressure switches NEMA 4X weatherproof thermoplastic enclosure High level alarm beacon and horn Model LA32 - Three Phase Duplex Controlled by float or pressure switches NEMA 4X (ultraviolet stabilized thermoplastic) Designed for Latin America market 32XR - Three Phase Duplex Operates with a 4-20mA transmitter Handles three voltages and wide range of pump motor amps by field installing overload modules - up to 32 amps each Features LCX3 controller CE Rated Control Panels Manufactured by SJE Rhombus Suzhou, our CE rated panels are manufactured to control one or two pumps Single phase and three phase models available Main power disconnect with interlock handle IP55 rated plastic or metal enclosure Various options available 7

ALARM SYSTEMS Xpert Alert Indoor alarm monitors 2 alarm conditions 120V primary power Sleek design features unique easy-to-see LED alarm light ring that illuminates red for alarm 1 and amber for alarm 2 Large test/silence button Low temperature indicator activates at 4 C (40 F) Large horn silence button on front of alarm Battery backup with low battery chirp Tank Alert AB Indoor alarm High or low level alarm 120 VAC primary voltage 9 VDC battery backup Low battery chirp Tank Alert EZ Indoor/Outdoor alarm 120V and 240V available Sleek, innovative design features distinct 2-color molded enclosure Integrated LED beacon Alarm test/silence switch Removable cover for easy installation External mounting tabs CE version available U.S. Patent No. 8,737,672 and D695,640 SJE Level Monitor CL Monitors tank levels using floatless C-Level sensor NEMA 1 rated for indoor use Power on and alarm indicators 10 segment LED bar graph displays level in the tank Test/silence, alarm level and set buttons Connects to a Level Monitoring Product C-Level Sensor Uses pressure to detect liquid level in tank and send signal to the IFS panel or SJE Level Monitor CL Compact design; low voltage Easy to adjust set points One sensor replaces up to 4 floats CL40 sensing range up to 101.6 cm (40 inches) or CL100 sensing range up to 254 cm (100 inches) 2 Mounting Bracket (optional accessory) Vent C-Level Sensor U.S. Patent No. 8,336,385, 8,567,242 and 8,650,949 8

CONTROL FLOATS Mechanically-activated, narrow-angle control floats (pilot duty) accurately monitor high (normally open) or low (normally closed) liquid level conditions to activate control panels and alarms. EZconnex 4-port Float Switch Connection System Manifold/float connection system designed for easy installation of float switches in a wet well for level control applications. Includes electrical wiring manifold with mounting bracket (float switches sold separately) Features (4) quick release float switch connection ports Rated for short term water submersion Manifold housing includes colored caps that match red-blue-yellowwhite wire pairs in manifold cable for easy field wiring 3 float version available US Pat. 9,559,455 and 9,583,867. Foreign Patents Pending. SJE MegaMaster Control Float Switch SJE MegaMaster control float switch is designed for municipal water and sewage applications. The internal switching mechanism has unique gold crosspoint contacts for reliable control of current up to 1 Amp. The unique two-tone float housing offers easy identification. Maximum Electric Load: 1 Amp, 125 VAC; Minimum Electric Load: 1mA, 4 VDC Activation angle is 10 degrees above and 10 degrees below horizontal Dimensions: 10.2 cm diameter x 16.8 cm long (4.03 diameter x 6.62 long) Cable: 18 gauge, 3 conductor, SJOW; 3 wire cable - SPDT (Single Pole, Double Throw) can be wired as normally open or normally closed CE version available Manufactuerd by SJE Rhombus Suzhou SJE SignalMaster Control Switch SJE SignalMaster Control switch is a mechanically-activated, narrow-angle float switch. Electric rating: 5A, 125/250 VAC Cable: 18/2 SJOW Control differential: 4 cm (1.5 in) above or below horizontal SJE SignalMaster SPDT Control Switch (3-wire) version available SJE MilliAmpMaster Control Switch SJE MilliAmpMaster Control switch is designed to activate low current AC or DC applications. It is available in narrow and wide angle configurations. Electric rating: 0.160mA - 100mA; 30 VDC, 125 VAC; 1mA, 5 VDC Cable: 18/2 SJOW Control differential: Narrow-angle: 4 cm (1.5 in); Wide-angle: 10 cm (4 in) above or below horizontal 9

PUMP FLOATS SJE Rhombus offers a complete line of mechanically-activated, wide-angle pump float switches that are designed to automatically control pumps up to 3 HP at 250 VAC. Each switch has an adjustable pumping range and various cord length options. Pump (inductive load) float applications include direct control of sump, sewage and effluent pumps, motor control and valve control. SJE Quest Pump Float - Latin America Package SJE Quest Pump Float - Latin America package is a mechanicallyactivated, wide-angle pump switch designed for performance and dependability. Packaged in bilingual bag (English and Spanish), designed to easily display for customers in Latin America. Electric rating: 6(4)A 250 VAC Cable: H05RN-F 3 conductor Pumping range: 23-91cm (9-36 in) Manufactured by SJE Rhombus Suzhou SJE Quest Pump Switch SJE Quest includes a patented sealing design that provides excellent protection from moisture entering the float housing. The float switches are available in multiple color options and are available with our innovative one-piece cable weight. Electric rating: 125/250 VAC, 50/60Hz, single phase, 10(10)A; 10(8)A; 6(4)A 4 Amp inductive load Cable: H07RN-F or H05RN-F, 2 or 3 conductor Pumping range: 23-91cm (9-36 in) Manufactured by SJE Rhombus Suzhou SJE Quest SJE MicroMaster Pump Switch SJE MicroMaster Pump Switch is a mechanically-activated float switch designed for wastewater and water applications. Electric rating: 10A, 125/250 VAC, 50/60Hz Single phase Cable: 18/2 SJOW Pumping range: 20-91cm (8-36 in) SJE MicroMaster Plus Pump Switch (13 amp) SJE MicroMaster SPDT Pump Switch (3-wire) version available SJE HiTempMaster Pump Switch SJE HiTempMaster Pump Switch is designed specifically for high temperature sump applications up to 93 C (200ºF). Pump down applications. Electrical rating: 13A, 125/250 VAC, 50/60Hz, single phase Cable: 16/2 SJOOW, 2 conductor Pumping range: 20-91cm (8-36 in) Twin wall design of float housing (patent pending) protects internal components from heat and moisture 10 SJE Quest II

PUMP FLOATS SJE PumpMaster WPS Float Switch SJE PumpMaster WPS is designed for direct control of pumps in potable water applications. Electrical rating: 1/2 HP at 125 VAC and 1 HP at 250 VAC or 125 VAC, 100 ma Cable: 16 gauge, 3 conductor SJOW Pumping range: 18-91 cm (7-36 in) CSA Certified to meet NSF/ANSI 61 standard for use in potable water. Approved for use in tanks of 950L (250 US gallon) in volume or greater per float SJE PumpMaster Pump Switch SJE PumpMaster Pump Switch has heavy-duty contacts and the cylinder shape make this float ideal for sewage applications. Electric rating: 13A, 125/250 VAC, 50/60Hz Single phase Cable: 16/2 SJOW Pumping range: 18-91cm (7-36 in) SJE PumpMaster Plus Pump Switch (15 amp) SJE PumpMaster SPDT Pump Switch (3-wire) version available SJE VerticalMaster II Pump Switch SJE VerticalMaster II Pump Switch features a vertical operating design that works well for smaller pump chambers where there is limited space. Electric rating: 10A, 125/250 VAC, 50/60Hz Single phase Cable: 18/2 SJOW or SJTOW Pumping range: 2-17cm (.75-6.5 in) SJE VerticalMaster II Plus Pump Switch (13 amp) version available SUB-X Transmitter SUB-X Transmitter measures the hydrostatic pressure of the water above the sensor and outputs a 4-20mA signal proportional to the level. 18/2 shielded cable with vent tube Measuring ranges: 7.25 PSI (16.7 ftwc) and 14.50 PSI (33.4 ftwc) Accuracy: 1% full scale Operating Temp: 0-50oC (32-122oF) Provided with removable lock in place stabilizing weight and stainless steel mounting bracket Float Accessories Float Brackets (4-6 floats) for installation of float switches Cable Weight provides pivot point for floats Cable Weight Mini provides pivot point for floats Float Brackets Cable Weight Mini Cable Weight 11

SJE Rhombus Corporate Headquarters, Detroit Lakes, Minnesota, USA Ashland, Ohio Clearwater, Florida Milford, Ohio New Hope, Minnesota Plymouth, Minnesota Suzhou, China Vacaville, California Since 1975, SJE Rhombus has become a global leader in the water and wastewater industry by developing innovative control products from eight locations that offer reliability and performance customers can depend on. SJE Rhombus offers a wide variety of control products for Residential and Commercial markets and serves the Irrigation, Municipal, and Industrial markets under the PRIMEX brand. SJE Rhombus controls can be found in applications including: Wastewater Lift Stations Sumps Pressure Booster Systems Sewers Treatment Plants Drains Wells Irrigation Systems From control panels utilizing embedded circuit board technology to complete control/ monitoring systems designed and built to customer specifications, SJE Rhombus represents the most reliable integration of engineering and manufacturing in the industry. New product designs endure extensive in-house and field testing before submittal to recognized independent laboratories for safety testing and approval. This commitment to quality ensures customers with a dependable, trouble free product. SJE Rhombus offers a five-year limited warranty on most products. Learn more at www.sjerhombus.com. Residential Commercial Irrigation Municipal Industrial 9500225B 2017 SJE Rhombus Rev 04/18