PHOTOELECTRIC DETECTOR

Similar documents
PHOTOELECTRIC DETECTOR

ACTIVE INFRARED PERIMETER DETECTION BEAMS & ENCLOSURES

This symbol indicates prohibition. The specific prohibited action is provided in and/or around the figure.

AX-100TFR/AX-200 TFR INTRODUCTION 1-1 BEFORE YOUR OPERATION BATTERY OPERATED PHOTOELECTRIC DETECTOR. Warning FEATURES. Caution. Warning.

Photoelectric Beam Detector

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

ENFORCER SENSOR MANUAL. Multi-Frequency Quad Photobeam Detectors

Quadruple-beam photoelectric detector

FEATURES OPTION 1.DESCRIPTION AND OPERATION 2.DETECTION AREA PASSIVE INFRARED AND MICROWAVE COMBINATION DETECTOR. No.

No INSTALLATION INSTRUCTIONS m (7.6-3 ft.) Far area mirror Masking plate for far area Fixing rubber form

HX-80NRAM. High Mount Outdoor Detector

HX-40/40AM/ 40DAM. High Mount Outdoor Detector

INDEX. Installation recommendation

English. Series. Installation and Use Manual

DATA CENTER SECURITY. March 2017 Anton Panaitescu

1 PRODUCT COMPONENTS This section describes the contents of the product package and the names and functions of

CONFIGURATION OF THE OPTICALS

AX-70TN, AX-130TN, AX-200TN AX-100TF, AX-200TF

CAUTIONS ON INSTALLATION

Twin Photobeam Detectors Manual

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

PARVIS Safe and tranquil thanks to Parvis

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

PHOTOELECTRIC BEAM SENSOR PB- 50HFA-KH PB-100HFA-KH PB-200HFA-KH

Long-Range Barrier Sensors

Description. Optex Incorporated

Installation And commissioning manual. Series S Double Beam 1/16

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

INDEX. Installation recommendation

RLS-3060SH REDSCAN ULTIMATE

RLS-3060SH REDSCAN ULTIMATE

FTN-RRHW/FTN-RRIX FTN-RR2G/FTN-RRDS

INDICE. Installation recommendation

INDEX. Installation recommendation

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

REDNET INFRARED BEAM SET TYPE RN4/10-25, RN4/25-75 & RN4/ INSTALLATION AND SET UP INSTRUCTIONS

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

Intrusion Outdoor Protection Perimeter

Solar Powered Wireless Photobeam Sensors

ADPRO PRO Series by Xtralis

other ambient light sources. Before installation, make sure to read this instruction manual carefully for safe and effective product operation.

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

Open-area Smoke Imaging Detection (OSID)

perimeter barriers Active infrared SAFET Y INSIDE AND OUTSIDE THE HOME WALL-FLUSH INTERNAL OR EXTERNAL PROTECTION EXTERNAL PROTECTION

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

INFRARED MODULATED BARRIERS

Light Walls HB-T001Q3 HB-T001R3

DUAL OPTIC. Installation manual

MADE TO PROTECT OUTDOOR DUAL-TECH CURTAIN DETECTORS AGATE / AOCD-250

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Movement Detector GJD 300

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

Fiber Optic Cable Fence Disturbance Sensor

Open-area Smoke Imaging Detection (OSID)

Motion Detectors. Whatever the application, there s a Paradox motion detector that will suit your needs and surpass your expectations.

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

SECURITY SENSORS PHOTOELECTRIC BEAMS PASSIVE INFRARED SENSORS FLAME SENSORS GLASS BREAK SENSORS DOOR SENSORS ATTENTION SENSORS

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

PHOTOELECTRIC BEAM SENSOR

Color Mark Sensor. Sensing gdsa distance Spot diameter e. Possible to switch between vertical or horizontal connection using the M12 rotary connector.

- Basic information of Laser Scan detector

Beam Sensor 100 Mtr Manual Wired Type & Convertible to Wireless Type Model: BS- Series Outdoor Use

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

BARRIERS & SENSORS Catalogue 2017

BARRIERE & SENSORI BARRIERS & SENSORS

talentum Flame detection across the spectrum Range Brochure

Intrusion. Outdoor protection perimeter

ADPRO PRO Passive Infrared Detector. Webinar November Ben Klösen, PLM

E3M-V. Mark Sensor. Applications

Fireray Application and. Installation Guide FEATURES. Range metres. 12V to 24V dc operation. Selectable alarm thresholds

SECURITY PRODUCTS CATALOGUE

COMBINATION SENSOR. COM-50XTL : OUTDOOR 165ft (50m) Instruction Manual

TITLE SLIDE. FIRERAY2000 EExd OPTICAL BEAM SMOKE DETECTOR. Doc. No: Copyright Fire Fighting Enterprises Ltd.

JUNE 2014 SECURITY SYSTEMS

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

English. Italiano. Português. Françias. Español

General Purpose Photoelectric Sensor

TRUST WIRELESS ALARM SYSTEM 200S

Product Range. Talentum - Why use our Flame Detectors? Product Support. Warranty.

KwêBeams Effective wire free outdoor early warning system

2 General Application Photoelectric Sensors

Photoelectric laser sensors E3C-LDA SERIES. l o n g - d i s t a n c e, a d j u s t a b l e l a s e r b e a m. Advanced Industrial Automation

10 to 30 VDC Diffuse 40 mm ±10 mm NPN and PNP, switch-selectable

D296/D297. Application Guide. Projected Beam Smoke Detectors

OIL FILM DETECTOR (Long-distance correspondence Version)

P E R I M E T E R m i n i c a t a l o g u e

Contents. Photoelectric Sensors / Standard Sensors...4. Safety Sensors Photoelectric Sensors / Miniature Sensors... 12

2 General Application Photoelectric Sensors

INTREPID Perimeter Intrusion Detection System

Reflective Beam Smoke Detector

The Affordable, All-Purpose Sensor That's EZ To Use!

Rota-Sonde DC4000-L. Laser pointer for easy alignment. Remote control of the sensitivity

THE NEXT GENERATION IN VISIBILITY SENSORS OUTPERFORM BOTH TRADITIONAL TRANSMISSOMETERS AND FORWARD SCATTER SENSORS

PIR MOTION SENSOR. PIR Motion Sensor (EKMB, EKMC, AMN2, 3)

PRODUCT INFORMATION HISIC450 OVERHEIGHT DETECTORS RELIABLE OVERHEIGHT DETECTION OF VEHICLES. Traffic sensors

2 General Application Photoelectric Sensors

Transcription:

PHOTOELECTRIC DETECTOR HARD-WIRED MODELS ADVANCED MODELS SL-200QDM : 60m / 200ft. SL-350QDM : 100m/ 350ft. SL-650QDM : 200m/ 650ft. STANDARD MODELS SL-200QDP: 60m / 200ft. SL-350QDP: 100m/ 350ft. SL-650QDP: 200m/ 650ft. BASIC MODELS SL-200QN: 60m / 200ft. SL-350QN: 100m/ 350ft. SL-650QN: 200m/ 650ft. BATTERY OPERATED MODELS STANDARD MODEL SL-350QFR : 100m / 350ft. BASIC MODEL SL-350QNR : 100m / 350ft.

Anyone can LOCK ON, Automatically LOCK ON. The IR transmitter and receiver must be perfectly aligned in order to achieve the optimal operation of the photoelectric detector. However, a great deal of patience, time and effort is required to ensure that the receiver is receiving the maximum amount of infrared signal possible from the transmitter. Optex has the solution the SL series is designed to lighten your workload while achieving perfect alignment. SNIPER VIEWFINDER TM X2 MAGNIFICATION LENS The new telescope lens has a high level of visibility for optical alignment work. Even over long distances, a perfect installation and stable performance can be achieved in a short period. Conventional model X2 magnification lens BEAM ALIGNMENT UNIT : BAU-4 (option) The BAU-4 beam alignment unit automatically and accurately adjusts the optical axis. This allows peak performance and gives one technician the ability to install the 200 m (650 ft.) Smart Line detector by himself. THE world first AUTOMATIC BEAM ALIGNMENT HORIZONTAL V E R TI C A L LED INDICATOR AND SOUND ASSIST SL-QDM: AND SL-QDP: only The alignment level indicators have 5 LEDs, each LED represents the level of alignment, ranging from poor to excellent. The optical alignment level can also be checked by sound. UPPER/LOWER BEAM SELECTION BUTTON SL-QDM/SL-QDP only: AND Optical alignment can be done without using a beam blocking plate since the SL has upper/lower beam selection button which enables to turn on and off the upper and lower beam alternately in the installation mode.

SHUT OUT ANY TROUBLES Double Modulation BeamSL-QDM/QDP only) 2nd Pulse Sunlight SLIM BODY & LIGHT WEIGHT 20% reduction of the body size and 15% reduction of the weight come together in the SL series. Transmitter 1st Pulse mercury-vapor lamp Receiver The SL-QDM and SL-QDP series offer double modulation beams that differ in pulse patterns. This can enhance signal discrimination against potential noise interference such as sunlight or other external light sources, resulting in a reduction of missed or false alarms. Together with OPTEX triple layered Sunshine Protection Technology, it ensures high reliability under the severe outdoor security environment. BEAM BLOCKING PLATE The plate can firmly be fixed on the lens unit without fear to be blown off by wind. The plates can be stored in the back of the front cover. QUAD BEAM & UNITED APPEARANCE By employing quad beam, it dramatically reduces false alarm caused by birds and falling leaves. Moreover, it is also important that the housing design of both long and short beams is harmonised. 60m (200ft.) range models, SL-200QN/SL-200QDP/SL-200QDM with a wide beam pitch is now available. Conventional short beam IP65 WATER/DUST PROTECTION Rubber seals is used for all conceivable points where water or dust may penetrate, such as wiring holes, wire ports and the outer openings on chassis. Smartline series UV-resistant POLY CARBONATE COVER Front cover is not clouded by ultraviolet ray during a long term. Therefore it will maintain the transparency of IR beams. ANTI FROST DESIGN (Hood design) The hoods are positioned on both the upper beam and the lower beam to secure a high and stable beam power by preventing frost from attaching to the front cover. VIVID INTERIOR COLOR Easy-to-see vivid interior color for optical alignment. CONVENTIONAL SL series ALIGNMENT DIAL The alignment no longer requires a screwdriver. All you need is touch with your fingers for precise adjustment. QUAD BEAM WITH ASPHERICAL LENSES The high-grade aspherical lens create more sharply defined and precise active infrared beams.

ENVIRONMENT RESISTANCE SUNSHINE PROTECTION TECHNOLOGY (SL-QDM/SL-QDP only) The sunshine protection technology has a triple layer construction to give better performance against external light sources (e.g.:the sun, mercury-vapour lamps, and fluorescent lights). 1 2 3 1 The front cover with 2 The photodiode 3 The light disturbance special filter materials to remove visible lights. devices with IR bandpass filter to transmit only the same wavelength of the IR beams. compensation circuit differentiates original double modulated beams from other external light sources. BEAM POWER CONTROL SELECTOR (SL-QDM/SL-QDP only) The beam power control selector allows you to manually adjust beam power from NORMAL to LOW or VERY LOW. This function is effective for the following purposes: For countermeasure against crosstalk due to reflection of wall or floor by reducing beam power. For countermeasure against interference due to unstable S/N (signal / noise) ratio when using multiple photo beams for long distance or beam stacking applications. LOW NORMAL VERY LOW To reduce beam power when using the detector for a distance shorter than the rated distance. VERY LOW To search the peak value when making optical alignment to support perfect alignment. NORMAL LOW A.T.P.C.-AUTOMATIC TRANSMIT POWER CONTROL (SL-QDM only) Patent pending Automatically controls, adjusts and optimizes the power of the beam and maintains optimal performance. It decreases false and missed alarms caused by fog, frost, cross talk, and signal saturation. Decreased beam power because of dense fog FOG Caused over beam power by the reflection from wall Decrease signal level (Signal saturation) due to rising sun or sunset which enter to the receiver at the same angle as the transmitted IR beams. signal level Sun(noise) RX TX Transmit power control signal POWER UP RX TX Transmit power control signal POWER DOWN IR Beams(signal) Time Boost beam power Reduce beam power to avoid unnecessary reflection Increase signal level to avoid signal saturation signal level Sun(noise) Beam Power UP IR Beams(signal) TX RX TX Beam Power DOWN RX Time

SELECTION GUIDE Most appropriate Appropriate HARD-WIRED MODELS ADVANCED STANDARD BASIC STANDARD BASIC SL-200QDM SL-350QDM SL-650QDM SL-200QDP SL-350QDP SL-650QDP SL-200QN SL-350QN SL-650QN SL-350QFR BATTERY OPERATED MODELS SL-350QNR SOLAR BATTERY SBU-4+ SL-QDM series LIGHT DISTURBANCE (Expected impact :False alarm) REFLECTION (Expected impact :Missed alarm) INTERFERENCE (Expected impact :Missed alarm) FOG (Expected impact :False alarm) LIGHTNING (Expected impact :Unit damage) FROST (Expected impact :False alarm) RE-TRANSMISSION FUNCTION LED INDICATOR AND SOUND ASSIST WIRELESS (BATTERY OPERATED)

HARD-WIRED MODELS ADVANCED MODEL SL-200QDM/350QDM/650QDM Detection range Beam frequencies Current consumption Ambient temperature Water protection Dimensions H х W х D Weight SL-200QDM 60m/200ft. SL-350QDM 4ch selectable Normal 26mA/Max. 60mA -35 C - +60 C (-30 F - 140 F) IP65 SL-650QDM 200m/650ft. 448 (17.6) x 79 (3.1) x 96 (3.8) mm(inch) 2500 g(88.2oz) POWER INPUT 10.5-30VDC [Normal] 3.6VDC [SBU-4] ALARM INPUT LOW BATTERY INPUT (using with SBU-4) TAMPER OUTPUT (N.C.) POWER INPUT 10.5-30VDC [Normal] 3.6VDC [SBU-4] D.Q.OUTPUT/ N.C. LOW BATTERY COM. OUTPUT N.C. ALARM OUTPUT COM. ALARM MEMORY INPUT LOW BATTERY INPUT (using with SBU-4) TAMPER OUTPUT(N.C.) STANDARD MODEL SL-200QDP/350QDP/650QDP POWER INPUT 10.5-30VDC POWER INPUT 10.5-30VDC Detection range Beam frequencies Current consumption Ambient temperature Water protection Dimensions H х W х D Weight SL-200QDP 60m/200ft. SL-350QDP 4ch selectable Normal 17mA/Max. 24mA -35 C - +60 C (-30 F - 140 F) IP65 SL-650QDP 200m/650ft. 448 (17.6) x 79 (3.1) x 96 (3.8) mm(inch) 2400g(84.6oz) TAMPER OUTPUT (N.C.) N.C. D.Q.OUTPUT COM. COM N.C. ALARM OUTPUT ALARM MEMORY INPUT TAMPER OUTPUT(N.C.) BASIC MODEL SL-200QN/350QN/650QN Smart design - Slim body - Vivid interior color Detection range Beam frequencies Current consumption Operating temperature Water protection Dimensions H х W х D Weight SL-200QN 60m/200ft. SL-350QN - 38-40mA -25 C - +60 C (-13 F - 140 F) IP65 SL-650QN 200m/650ft. 448 (17.6) x 79 (3.1) x 96 (3.8) mm(inch) 2400g(84.6oz) POWER INPUT 10.5-30VDC TAMPER OUTPUT (N.C.) POWER INPUT 10.5-30VDC N.C. ALARM OUTPUT COM. TAMPER OUTPUT(N.C.)

OK NG ENTER BATTERY OPERATED MODELS NO WIRING for POWER, NO WIRING for SIGNAL. STANDARD MODEL SL-350QFR Long distance 100m / 350ft. Long battery life - 4 to 8 years Spacious back box for wireless transmitter BASIC MODEL SL-350QNR Main unit Back box Main unit Back box Power input (+) Power input (-) Power input (+) Power input (-) Low Battery output Low Battery output Tamper output Tamper output DQ output DQ output Alarm output Alarm output Low Battery output Low Battery output Tamper output Tamper output Detection range Beam frequencies Power source Current consumption Operating temperature Water protection Dimensions H х W х D Weight SL350QFR 4ch selectable SL-350QNR - Recommend: 3.6 V, 13.0Ah LSH20 lithium batteries manufactured by SAFT Operating range: 3.2 V - 4.0 V lithium batteries Transmitter: 2 or 4 units, Receiver: 2 or 4 units 745μA -20 C - +60 C (-4 F - 140 F) IP65 452 (17.9) x 83 (3.3) x 138 (5.4) mm(inch) 3300 g OPTION LONG DISTANCE 200m, WIRELESS READY. SOLAR BATTERY UNIT (OPTION) SBU-4 for SL-200QDM/SL-350QDM/SL-650QDM only Small size and light weight Li-ion battery pack Long battery life - Non-sunshine days : approx. 7 days Spacious back box for wireless transmitter Battery common use unit (BCU-4 option) Anti-bird needle Included POWER INPUT LOW BATTERY OUTPUT HARD-WIRED PANEL The detector is sold separately. WIRELESS Replacement battery Rechargeable Li-ion Battery Pack LB-4 Approx. 2900 mah Recharging time Charging battery protection circuit Low battery output Alignment angle Mounting SBU-4 Approx. 1 hour on sunshine day Approx. 6 hours on cloudy day Charging is suspended at approx. -5 C or less,or approx. 60 C or more. Form C relay: 28 VDC, 0.2 ALow battery detection voltage: 3.4 V Horizontal : ±180 30-degree pitch Vertical : +15 - +90 (5 pitch Under eave mounting+0 - +55 5 pitch

VARIOUS OPTIONS Anti Bird Cap ABC-4 Back Cover BC-4 Pole Side Cover PSC-4 Conduit Bracket CBR-4 Prevents birds and small animals from sitting on the detector. Protects the front of the detector from excessive rain and snow. Conceals the back side of a pole mounted detector. Conceals the gap between two pole mounted detectors in back to back. Patent pending Heating Unit HU-3 for Hard-wired models Solar Battery Unit SBU-4 for SL-QDM only Extension Cable with Connector EC-4 for SL-QFR/QNR only Power input Current draw Thermo switch 24VAC/DC 420mA(max.) (Per 1 unit) 60 C (140 F) Supplies power by high efficiency solar battery. Li-ion rechargeable battery and Anti-Bird Needles are included. Extension cables between the back box and the main unit. When installing in a beam tower. Wall mount Pole mount Cable length: 500 mm (19.7 inch) Battery Common Unit BCU-4 for SL-QFR/QNR AX-TFR only Shares power source and low battery signals between the main unit and the wireless transmitter. Beam Alignment Unit BAU-4 Aligns optical axis automatically. (SL-QDP/QN/QFR/QNR: applicable to receiver only) Patent pending Input voltage Current draw Output voltage Output current Operating temperature Operating humidity 3.2-4.0 VDC Approx. 5 μa at 3.6 VDC (no load) Normal Approx. 2.3-3.6 VDC Low battery Approx. 2.0-2.6 VDC 100 ma (max.) -20 C - +60 C (-40 F - +140 F) 95% (max.) SHORT RANGE MODELS AX-100TFR/200TFR BATTERY OPERATED PHOTOELECTRIC DETECTOR AX-100TFR : Detection range 30m / 100ft. AX-200TFR : Detection range 60m / 200ft. AX-70TN/130TN/200TN SHORT RANGE PHOTOELECTRIC DETECTOR AX-70TN : Detection range 20m / 70ft. AX-130TN : Detection range 40m / 130ft. AX-200TN : Detection range 60m / 200ft. AX-100TF/200TF 4ch. BEAM FREQENCIES SELECTABLE MODELS AX-100TF : Detection range 30m / 100ft. AX-200TF : Detection range 60m / 200ft. OPTEX CO., LTD. (JAPAN) URL: http://www.optex.net/ OPTEX INC. (U.S.) URL: http://www.optexamerica.com/ OPTEX DO BRASIL LTDA. (Brazil) URL: http://www.optex.net/br/es/sec/ OPTEX (EUROPE) LTD. / EMEA HQ (U.K.) URL: http://www.optexeurope.com/ OPTEX TECHNOLOGIES B.V. (The Netherlands) URL: http://www.optex.nl/ OPTEX SECURITY SAS (France) URL: http://www.optex-security.com/ OPTEX SECURITY Sp.z o.o. (Poland) URL: http://www.optex.com.pl/ OPTEX PINNACLE INDIA, PVT., LTD. (India) URL: http://www.optex.net./in/en/sec/ OPTEX KOREA CO.,LTD. (Korea) URL: http://www.optexkorea.com/ OPTEX (DONGGUAN) CO.,LTD. SHANGHAI OFFICE (China) URL: http://www.optexchina.com/ No. 77043 01 15747 1405