CHIME RECEIVER INSTALLATION & OPERATING. Cat No. TLRXC1 INSTRUCTIONS

Similar documents
BATTERY POWERED DETECTOR/ TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTXDCB INSTRUCTIONS

DETECTOR TRANSMITTER INSTALLATION & OPERATING. Cat No. TLTX2000B INSTRUCTIONS

Chime Receiver E-996 INSTALLER GUIDE. SF-DCC-RX.qxd 13/04/ :30 Page 1

Lantern Receiver E-997 INSTALLER GUIDE. SF-LA-BC-RX-W.qxd 13/04/ :36 Page 1

360º FLUSH MOUNT CEILING PIR LIGHT CONTROLLER INSTALLATION & OPERATING. Cat No. SLFM360 INSTRUCTIONS

2000W PIR LIGHT CONTROLLER SLB2000-Black SLW2000-White INSTALLATION & OPERATING INSTRUCTIONS

60W Multi PIR Bulkhead

High Frequency Sensor

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

DOOR & WINDOW ALARM INSTALLATION & OPERATING. Cat No. TG232W INSTRUCTIONS

360 Surface Mount Ceiling PIR Light Controller

360 Ceiling PIR Light Controller

Programmable Security Light Switch

360º Surface Mount Ceiling PIR Light Controller

Surface Mount Wall PIR Light Controller. Model: PDWM1500. Installation & Operating Instructions

Cat. No TPT44. Installation & Operating Instructions

5W LED Energy Saver PIR Bulkhead

Model: PDSM1500. Installation & Operating Instructions 360º Surface Mount Ceiling PIR Light Controller

30W LED PIR FLOODLIGHT. Model: LEDX30PIRB Model: LEDX30PIRWH

Model: PDFM1500. Installation & Operating Instructions 360º Flush Mount Ceiling PIR Light Controller

18W Round LED Wall/Ceiling Light with Microwave Sensor

12W Round LED Wall/Ceiling Light with Microwave Sensor

Cylinder/Pipe Thermostat Cat. No. TRT044. Operating & Installation Instructions

Battery Powered Electronic Programmable Room Thermostat Cat. No. TRT035. Operating & Installation Instructions

Battery Powered Electronic Programmable Room Thermostat

Battery Powered Electronic Room Thermostat Cat. No. TRT033

Emergency Assist Alarm Kit Single Zone

Illuminating. Solutions. for Energy Saving. Featuring the latest PIR Lighting solutions from Timeguard.

Getting Started with

Getting Started with

Security Light Transmitter

Electronic Room Thermostat Cat. No. TRT030

LED Lighting. Solutions

Electronic Frost Thermostat

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Safety! Seasonal INSIDE THIS ISSUE. Small and Powerful LED lighting Energy Saving without compromise.

TIMEGUARD WEATHERSAFE OUTDOOR POWER RANGE INSTALLATION & OPERATING INSTRUCTIONS

A1UL PERS. Personal Emergency Response System. For Technical Support Please Contact Your Service Provider Or Distributor

Supervised Security System Owner's Guide

754 Series. See Motion Sensors. in a new light. Sleek new styling and more features than ever before.

Installation & Operating Instructions

OPERATING GUIDE FOR YOUR RP1054D KEYPAD

. w. POWERHOUSE n MOTION DETECTOR MODEL PR511 OWNER S MANUAL

Digital Room Thermostat with Night Set-back

LED Lighting. Solutions

CPVan Home Alarm Starter Kit

Infrascan Passive Infrared Motion Sensor Surface-Mount 753SSR Series. Installation Instructions

WIRELESS ALARM SYSTEM WITH TELEPHONE AUTO DIALER

Lighten. the Load! MASTERS. SUPPLY! Timeguard s range of Fused Spur Timeswitches. Savings! LIGHTING. Countdown. On Demand! ALSO INSIDE THIS ISSUE

START-LINE Receiver ACD-200. SMART Home USER MANUAL. Version 1.0 Visit for the most recent user manuals MAINS SOCKET DIMMER

60W Security Spotlight. 754HB1/180/ Outdoor Motion Sensor. Installation Instructions. Please leave these instructions at the installation site.

Super. Bright. Lumens! Super. Slim!

Detector switch - Dual Tech

Supervised Security System Owner s Manual

Master Code Arming Auto-Bypass Option - Home-Away Arming Entry Delay Off Arming

LED Lighting Solutions

Professional, Rewireable, Linkable LED Lighting

MEDI-MINDER USER MANUAL

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

EasyLoader. End User Manual

GI1DPC/B User Guide. Mains tungsten GLS filament or halogen lamp Min 60W Max 300W. Linear fluorescent

"Options" Sensor Module

TOCR02 2 PART MICRO MOTION SENSOR W/IR REMOTE CONTROLLER

SK642 THE TELEPHONE DIALER REQUIRES A LAND TELEPHONE LINE TO MAKE OUTGOING CALLS AND ELECTRICITY.

Wireless Keypads LKP(E)S8M Series

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

HSA % wirefree security alarm system. Installation Programming Operating. Helpline Intelligent Security & Fire Ltd

To activate using remote control: press [ ] key once. To activate using keyboard: on panel keyboard [ ] keys once.

NITETIME PRO. Wireless Timer. English. Owner s Guide and Installation Manual. Model Form#

OPERATING GUIDE for your GEM-RP1CAe2 KEYPAD

Product and Applications Description

Watchguard WGAP864 User Manual

PMCSF6 OCCUPANCY SENSOR

Compact Movement Activated Sensor Installation Instructions

Indoor Infrascan Passive Infrared Motion Sensor. Series. Installation Instructions. Please leave these instructions at the installation site.

READ ME FIRST DIY WIRELESS ALERT. Driveway Alert Kit. Instruction Manual

Radio Frequency Do s & Don ts

Protect anything, anywhere, anytime.

Passive Infrared (PIR) Wall Switch Occupancy Sensor Dual Circuit

Installation Instructions

Thank you for choosing Ideal Security s Home Security System with Telephone Dialer.

USER GUIDE HARDWIRED CONTROL PANELS

Driveway Alarm INSTALLATION MANUAL.

e-sense move dali Manual

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

User s Guide. SUB-MA7240O-0001.OG.Solution doc. Created: 6/05/03. Last Updated: 23/09/03. MA7240AO-0001 Version 1.0

Installation Instructions

3 ZONE WIREFREE BURGLAR ALARM INSTALLATION & OPERATING INSTRUCTIONS

Sonic Safety. Sonic Safety. Wireless Safety and Security System. HG-1500 System. For System Package OWNER S MANUAL

D3D Wi-Fi GSM Smart Alarm System -User Manual

Interactive Technologies Inc North 2nd Street North St. Paul, MN Technical Manuals Online! -

User s Information Guide R2A

PRODUCT CATALOGUE. Cape Town 18 Darter Road Blue Water Estate Kommetjie. Gauteng 245 Louis Botha Avenue Orchards Johannesburg

636 and 646 Keypads. User s Manual

Using Your. Security System With LED Keypad S5030, S5031, S5032

Wireless Keypad GKP-S8M

It is important to install this product in accordance with the fitting instructions below. Failure to do so may render your guarantee void.

ARROWHEAD ALARM PRODUCTS Ltd. 344b Rosedale Rd, Albany, Auckland. Ph Fax v1.0

Transcription:

CHIME RECEIVER Cat No. TLRXC1 INSTALLATION & OPERATING INSTRUCTIONS

1 Introduction The TLRXC1 Chime Receiver is part of the Timeguard range of PIR products which communicate by radio frequency (r.f.) signals. This enables substantial amounts of wiring to be eliminated which is particularly useful in long runs and coverage of outbuildings. It is a plug in adapter which receives r.f. signals from transmitters (denoted by Tx in the range) that it has been programmed to recognise and produces an audible warning as well as turning on lights connected to its socket outlet. In the following instructions products with catalogue numbers including TX (ones that send information about PIR detection) are referred to as Tx units and products with catalogue numbers including RX (ones that receive information about PIR detection) are referred to as Rx units. Tone/Volume Manual Override LED PROG Program/Reset Time On

2 Parts included Chime Receiver unit. Instruction manual. Please keep safe for future reference. Selecting a location 1. Position your Transmitter in desired area, if using a PIR perform walk tests to confirm detection zones. 2. Position TLRXC1 in a desired area up to 100m away from the Tx, take into account the path between the sensor to ensure range is acceptable. The Chime Rx can be placed in any socket outlet within the home, it can be used purely as a sounder, reacting to any transmission signals it receives from any Tx or it can be used to switch an internal lamp on/off as desired. We suggest that firstly, the Floodlight Tx is placed in its optimum position to give the coverage and detection required, then the Chime Rx is fitted to a socket outlet at a point where it can receive the Tx`s signal. (This will be less than 100m away if walls or chain link fences come between the Tx and Rx units - if there is any doubt about whether communication will take place make temporary installations before programming).

3 Installation 1. If you require an internal lamp to be switched by the Floodlight Tx, plug a lamp (500W max incandescent or halogen) into the unit s socket outlet. (The TLRXC1 is not suitable for switching fluorescent, low energy or discharge lamps). Ensure the lamp is switched on when operation is required. 2. Plug the Chime Rx into the wall outlet. The chime will then scroll through 6 audible sounds to inform the user of its sound options. There will then be four beeps and the flashing LED indicates that the Rx is ready for programming. Note:- This will only happen the first time the Chime Rx is plugged into the outlet. Programming PLEASE REFER TO THE INDIVIDUAL INSTRUCTION MANUALS OF THE Tx UNITS TO BE USED WITH THE TLRXC1. Each Rx unit needs to learn the codes included in the messages from all the Tx units which are required to control it (up to 17).

1 Turn OFF/remove batteries from any Tx unit which is not required to control this Rx unit. Turn off any other Rx units. If it is convenient more than one Rx unit can learn the code of a Tx unit simultaneously in which case leave these Rx units switched on.* 2 The TLRXC1 unit needs to be set in Program Mode. Plug it in to a live socket (the first time this is done the unit will go through its 6 choices of audible warning). Plug a lamp into the unit s socket and turn the lamp switch on. The LED on the unit will flash slowly for 5 minutes indicating it is in Program Mode. 4 3 4 Go to the Tx** unit to be introduced to the TLRXC1 and move across the face of its PIR lens within detection range to cause it to detect (indicated by the lights under control turning on for most Tx units and by a flash from the red LED on the TLTXDCB). The TLRXC1 will respond with a beep and the lamp plugged into it will turn on (indicating correct code learning). * Any other Rx units left connected should now be checked in the same way. 5 If an additional Tx unit is required to be introduced press the PROGRAM/RESET button for 1 to 2 seconds*** a single beep will sound and the LED will stop flashing and stay on indicating exit from Program Mode. Press this button again and the LED will start to flash again indicating a new 5 minute period of Program Mode. *Any other Rx units required to learn the code of this new Tx unit should be left connected. ** If introducing the TLTXK2 hand held transmitter press the 1 button on this unit to activate the TLRXC1. ***If the button is pressed for 5 seconds or more then all the codes that have been learnt will be erased.

Selecting the alarm/lamp function 1. Press the PROGRAM/RESET button for 1 to 2 seconds. (A beep will sound and the LED will flash indicating the unit is in Program Mode). 2. Make a TX unit which has been introduced detect. Press the TONE/VOLUME button to select the preferred sound (each will play twice, choose the first if you want the lamp to turn on, the second if you want the lamp to remain off). 3. Press the PROGRAM/RESET button. A beep will sound and the LED will stop flashing and remain on indicating exit from Program Mode. 5 Selecting the lamp on time To set how long the lamp will remain on after the TLRXC1 has received a signal from a Tx unit, set the ON TIME dial anywhere from 5 seconds ( minus setting) to 15 minutes ( plus setting). Selecting the volume To set the volume for the chime tone, make a Tx unit which has been introduced detect and the Rx unit will play the tone you have chosen. Press the TONE/ VOLUME button to select the volume you require high, low or beep. You cannot change the volume whilst the TLRXC1 is in Program Mode.

Manual override The Lamp can be switched ON/OFF independently of any transmission signal by using the MANUAL button. Press this button and the lamp will turn ON. The LED will flash indicating it is in Manual Mode. To return to Auto Mode, press the button again and the light will turn off. The LED will light permanently to indicate the product is in Auto Mode. Note:- If the Floodlight Transmitter detects movement when the Chime Rx is in Manual Mode, it will send a signal to the Chime Rx which will play its programmed sound and the connected light will blink off and on once quickly. 6 Erasing all codes Tx unit codes can be erased for reprogramming. To erase codes, while the TLRXC1 is powered, press and hold the PROGRAM/RESET button for more than 5 seconds. All programmed codes will be erased and 4 "beeps" will sound. This will clear the unit of all programmed codes and place it into the Program Mode.

Troubleshooting guide 7 Problem Chime/Lamp will not turn on when motion is sensed. Chime/Lamp comes on in Daylight Chime/light comes on for no apparent reason Light comes on irregularly when motion is sensed. Battery operated Tx unit LED flashes off and on twice when activated Solution 1. The lamp switch is turned off. 2. Check Light bulb. 3. Tx unit photocell determines it is daylight, adjust Tx units DUSK/ DAWN control for daylight operation. 4. Tx unit is too far from Rx unit, move closer. 1. Sticker over photocell window has not been removed from Tx unit. 2. Sensor is installed in a dark location, adjust DUSK/DAWN control. 3. The TLRXC1 is set in Manual mode. Press the MANUAL button once to return to Auto Mode. 1. Tx unit may be sensing small animals or passing cars. Adjust horizontal position or mask lens. 2. Reduce range by pointing the Tx unit detector down more. 1. Tx unit is too far from TLRXC1. Move closer. This is the Low battery signal. replace batteries in the Tx unit.

Technical specifications Power Supply: 230 V AC ~ 50Hz Maximum Switchable Load: 500W filament/incandescent only (not suitable for fluorescent, low energy or discharge lighting) Time On Adjustment: Transmission Range: Conforms to Directives: 5 seconds to 15 minutes Up to 100m (varies with surrounding structures) 73/23/EEC and 89/336/EEC 8

5 Year Guarantee In the unlikely event of this product becoming faulty due to defective material or manufacture within 5 years of the date of purchase, please return it to your supplier in the first year with proof of purchase and it will be replaced free of charge. For years 2 to 5 or any difficulty in the first year telephone the helpline on 020 8450 0515. FIVE YEAR 5 GUARANTEE HELPLINE 020-8450-0515 For a product brochure please contact: Timeguard Ltd. Victory Park, 400 Edgware Road, London NW2 6ND 020-8452-1112 or email csc@timeguard.com