AS-V/186K Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual

Similar documents
Hydroflo INSTALLATION & OPERATION MANUAL

PurTest PT Series INSTALLATION & OPERATION MANUAL

GDS Series INSTALLATION & OPERATION MANUAL

Triton Series INSTALLATION & OPERATION MANUAL

GDS Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual MODELS: GDS-7 GDS-15

PFC Series. Ultraviolet Disinfection Systems. Installation, Operation and Maintenance Manual MODELS: PFC-8 PFC-12 PFC-20.

EV Series INSTALLATION & OPERATION MANUAL

Ultraviolet Water Sterilizer Installation and Maintenance Manual

VMS-3. Part Number: Ultraviolet Systems VMS-3. Installation, Operation & Maintenance

Ultraviolet Disinfection Unit Installation and Owners Manual

SUPER NOVA SERIES UV STERILIZER HIGH INTENSITY ULTRAVIOLET STERILIZATION

1020 Industrial Drive, Orlinda, TN fax

INSTALLATION INSTRUCTIONS & OWNER'S MANUAL!!!!!!!!! P/N

Heater Upgrade Instructions

Instructions for Emperor Aquatics, Inc. s 16, 25, & 57 Watt Retro-Fit UV Sterilizer (for Savio s Skimmers)

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

INSTALLATION AND OPERATING INSTRUCTIONS FOR RW519 RAIN WATER FILTRATION SYSTEM

Ultraviolet (UV) Water Treatment System

Ultraviolet Systems UV-C 50 INSTALLATION INSTRUCTIONS & PRODUCT MANUAL

gamma pond Ultraviolet Sterilizers

ADVANCE Ultraviolet (UV) Water Treatment System

I N S T A L L A T I O N, O P E R A T I O N, M A I N T E N A N C E M A N U A L UVR SERIES ULTRAVIOLET WATER TREATMENT SYSTEM

Ultraviolet (UV) Disinfection System Model RC8

Owner s Manual. DO NOT REMOVE FROM UNIT See back cover for vital records

375 Marcus Boulevard Hauppauge, NY USA Fax: Extensive Product Information Available at:

HydroRite UVO 3. Troubleshooting Guide Residential. TSG-UVO158a. Copyright 2015 Hayward Industries Inc.

INSTALLATION MANUAL & OWNER S GUIDE. Stainless Steel Ultraviolet Water Purification System

Ultraviolet Monitoring System. Part Numbers UV/MS-1 V3 UV/MS-2 V3. Installation And Operations Manual

Bio-Logic. Owner s Manual. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Ballast 120v 50/60 Hz

Manuel Guide Lighting Fixtures

Ballast 230v 50/60Hz MIN B B MIN B B MIN B B

Installation & Operating Guide

Installation and Maintenance Manual

WEDECO DLR A SERIES ULTRAVIOLET WATER DISINFECTION UNIT INSTALLATION OPERATION AND MAINTENANCE MANUAL MODELS DLR-A SERIES NO'S

SLT-Series Installation and maintenance instructions

Models 120v 50/60 Hz 230v 50/60Hz MIN B A MIN B A MIN B A

Customized Drinking Water

Owner s Manual. Installation, Operation and Maintenance. SPV-200, SPV-410, spv-600, spv-740, spv-950

PRE INSTALLATION PROCEDURES

GROWMAX WATER Perfect Water for Plants and Gardens

SimplyClear Pressurized Filter Product Manual

INSTALLATION & MAINTENANCE

Document No E1 Revised February Atlantic Ultraviolet Corporation

Instruction Sheet DANGER

READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS

Installation & Service Guide

Ballast MIN A

(UV) - R830F & ) INTRODUCTION

WL380 QUICK START GUIDE

254 Nanometer Germicidal UV Disinfection Systems

PRE INSTALLATION PROCEDURES

Owner s Manual. Ultraviolet Water Purification System S80, SM80, SV50

Owner s Manual. Model: Powered by. D4 Validated Models: D4-V _RevAC

Owner s Manual. Installation, Operation & Maintenance. Models S17A, S23A, S37C & S50C U LTRAVIOLET WATER PURIFIERS

Operation & Installation Instructions

OWNER S MANUAL Operation & Installation Instructions

Instruction Sheet DANGER

Installation, Operation, and Maintenance Manual

Owner s Manual. Ultraviolet Water Purification System. Pro Series (Pro10, Pro20 & Pro30) Plus Series (G+, H+, J+) Basic Series (G, H, J)

S-Series. Protect your water from pathogens and disease with the UV-Guard S-Series. Protect:

UV Lamp and Quartz Sleeve Replacement/Maintenance

K Specifications. Max. Water Volume

K Specifications. Max. Water Volume

A measured step forward

Owner s Manual. Installation, Operation & Maintenance. Models S2400C, S5000C, S15000C, S20000C & S25,000C High Capacity Systems

J-PRO V 230V Dual Voltage Chlorinator Installation & Start-Up Guide

Owner s Manual. Installation, Operation and Maintenance. SC200-DWS11, SCm200-DWS11. Manufactured in Canada by:

REGISTERED HANDBOOK. Document: ECN: Revision: C. MANUAL, O&M TrojanUVLogic TM System Systems Without Wiper AM, VM & TM Models

Operation & Installation Instructions

SERVICE REQUIREMENTS

OWNERS MANUAL. Operation & Installation Instructions.

OWNERS MANUAL. Operation & Installation Instructions

Installation & operating manual. Swimming pool water. UV disinfection device UV10+

Model K 520 M Part No

Owner s Manual MIGHTY PURE. Installation, Operation & Maintenance ULTRAVIOLET WATER PURIFIERS. Models MP16A, MP22A, MP36C & MP49C

HOW YOUR UV DISINFECTION WORKS

S17A, S23A, S37C & S50C

ALL-IN-ONE SF PF312 MAR PMAX All-In-One Instructions.indd 1 3/1/2017 9:20 AM

Viking Installation Guide

PRF-RO Pentair Reverse Osmosis System Installation and Maintenance Manual SAFETY GUIDES THE BASIC REVERSE OSMOSIS SYSTEM. Tools and Materials Required

ULTRAVIOLET WATER PURIFIERS

Models S2400C, S5,000C S25,000C High Capacity Systems. Read and Follow All Safety Instructions. Save These Instructions.

Steril Air mobil. Owner s Manual. GENTRA Rıhtım cd. Yuva sk. No: ¾ Beyoğlu İstanbul Turkey Tel : Fax:

OWNERS MANUAL. Operation & Installation Instructions. L12, L22, L41, L57, L79 (Standard Output) H38, H53, H95, H151 (High Output)

ULTRAVIOLET WATER PURIFIERS

SmartStream UV. Ultraviolet Water Disinfection System. Maximize Water Quality Without Chemicals. Watts.com

Table of Contents. List of Figures

Owner's Manual. Models: 400-USUV-10, 400-USUV- 20, 400-USUV-30. Visit us online at Powered by

K 2.90 M. Specifications Operating pressure, max PSI Water volume GPM Voltage V Amp draw AMPS

1 P a g e. G4 Counter Top OPERATION MANUAL

DISHWASHER. Models DW2432 and DW2432SS. Installation Manual. Write Serial Number (on inner door of unit) here:

* If the infiniti UV Water Treatment System has an S2 Starter, it is fully interchangeable with the UV Lamp with Glow Starter.

NANO TECH UV-C DISINFECTION SYSTEM

Conduit ~15" Inlet. UV Sterilizer - Connection to Forcemain

Owner s Manual. Healthy, clean and safe. Installation, Operation and Maintenance

Ultraviolet (UV) Monitoring System - Open Channel Horizontal Systems Operation and Maintenance Manual

K 3.97 M. Specifications or visit our website: In USA call: Part No

Owner s Manual. Models: PUV -7 PUV -14

AllClear G2 Series Pressurized Filters Product Manual

J-PRO-22 Pump Proportional Feed Chlorinator Installation & Start-Up Guide

Transcription:

AS-V/186K Series Ultraviolet Disinfection Systems MODELS: AS-V 16 AS-V 26 AS-V 36 AS-V 38 AS-V 48 ATS-186K-10 ATS-186K-20 ATS-186K-40 ATS-186K-60 ATS-186K-80 ATS-186K-120 ATS-186K-240 ATS-186K-480 Installation, Operation and Maintenance Manual CAUTION: Read and Follow all safety rules and operating instructions before first use of product. DEALER NAME: DEALER PHONE #: MODEL #: SERIAL #: DATE INSTALLED: Aqua Treatment Service, Inc. 194 Hempt Road Mechanicsburg, PA 17050 www.aquat.com

www.aquat.com Aqua Treatment Service, Inc. 2012

Table of Contents Installation Instructions: General Safety Instructions... 2 Function / Description... 3 Installation... 4 Installation Diagram... 5 Sanitation Procedure... 6 Maintenance:... 7 Electronic Control: Parts Breakdown: General Overview... 8 Standard System Setup... 9 Monitor System Setup... 11 Unit... 12 Electronic Control System... 13 Specifications:... 14 Dimensions:... 15 Troubleshooting:... 16 Warranty:... 17 www.aquat.com Aqua Treatment Service, Inc. 2014 1

General Safety Instructions WARNING - to guard against injury, basic safety precautions should be observed, including the following: 1. READ AND FOLLOW ALL SAFETY INSTRUCTIONS. 2. DANGER - To avoid possible electric shock, special care should be taken since water is present near electrical equipment. Unless a situation is encountered that is explicitly addressed by the provided maintenance and troubleshooting sections, do not attempt repairs yourself, refer to an authorized service facility. 3. Carefully examine the disinfection system after installation. It should not be plugged in if there is water on parts not intended to be wet. 4. Do not operate the disinfection system if it has a damaged power cord or plug, if it is malfunctioning or if it is dropped or damaged in any manner. 1. SAVE THESE INSTRUCTIONS. 2. WARNING: The light given off by this unit can cause serious burns to unprotected eyes and skin. Never look directly at a lit UV lamp. When performing any work on the UV Disinfection System, always unplug the unit first. Never operate the UV system while the lamp is outside of the UV chamber. 3. WARNING: The UV lamp inside of the disinfection system is rated at an effective life of approximately 12,000 hours. To ensure continuous water treatment, replace the UV lamp annually with the appropriate Aqua Treatment Services UV lamp. Failure to comply may present a fire hazard. 5. Always shut off water flow and unplug the disinfection system before performing cleaning or maintenance activities. Never yank the power cord to remove it from an outlet. Grasp the plug and pull to disconnect. 6. Do not use this disinfection system for other than the intended use (potable water applications.) The use of attachments not approved, recommended or sold by the manufacturer / distributor may cause an unsafe condition. 7. Intended for indoor use. Do not install this disinfection system where it will be exposed to the weather. Do not store this disinfection system where it will be exposed to temperatures below freezing unless all the water has been drained from it and the water supply has been disconnected. 8. Read and observe all the important notices and warnings on the water disinfection system. 9. If an extension cord is necessary, a cord with a proper rating should be used. A cord rated for less Amperes or Watts than the disinfection system rating may over heat. Care should be taken to arrange the cord so that it will not be tripped over or accidentally pulled from the outlet. 2 Aqua Treatment Service, Inc. 2014 www.aquat.com

Function The function of this ultraviolet disinfection unit is to provide in excess of 99% reduction of all water borne pathogenic (disease causing) bacteria. The 186K Series will provide >4Log Reduction or 99.99% of bacteria, cysts, and viruses including adenovirus. Applications: Ultraviolet Germicidal Disinfection A.T.S. Ultraviolet Disinfection Units are designed to destroy micro-organisms in water supplies. The Ultraviolet lamp peak radiation of 254 nanometer wavelength (nm) destroys or inactivates the D.N.A. (deoxyribonucleic acid) which absorbs the Ultraviolet radiation. A.T.S. Germicidal Disinfection units meet minimum dosages of 30,000 microwatt second per square centimeter. The 186K Series provides in excess of 186,000uws/cm2 UV dose.maximum CONCENTRATION LEVELS BEFORE ULTRAVIOLET: Turbidity...5 NTU Hardness...7 gpg Color...None Iron...0.3 ppm Manganese...0.05 ppm ph...6.5-9.5ppm Important Note - Pre-filtration equipment may be required if these parameters cannot be maintained. Flow rate must not exceed rated capacity of the unit. Description The AS-V series are of unique design with an ultraviolet germicidal lamp housed within a single quartz sleeve surrounded by a stainless steel pressure chamber. The chamber is fabricated out of 304 Stainless Steel. A removable stainless steel cover exposes electrical components for servicing, when required. The AS-V series come with an ultraviolet lamp designed with a four pin single end connection. The quartz sleeve is intended to be placed through the disinfection chamber and will slightly protrude from each hole in the top plate. The ultraviolet lamp is placed within this quartz sleeve. The U.V. light shines through this specially designed hard quartz sleeve for maximum disinfection efficiency to meet the requirements for bacteria reduction in potable water. The inlet is located at the bottom of the chamber and the outlet is located on the side of the chamber. A Site Port is provided for safe and easy view of operation. www.aquat.com Aqua Treatment Service, Inc. 2014 3

Installation Pre-Installation Check List Water Pressure If the water pressure is over 100 psi, a pressure reducing valve must be installed before the equipment and set at 85 psi Electrical A grounded electrical outlet with a continuous supply of 110 to 120 volt - 60 hertz current should be located at installation site of the equipment. A drain, must be available within 20 feet of the equipment. Location of the equipment must be where it is not subject to freezing, direct sunlight or room Temperature over 120 F. The equipment must be installed on the cold water line after the well pressure tank or water meter and before it branches off to the water heater. Before putting the unit into final operation follow sanitation procedures as outlined in this manual for proper disinfection. Sanitizing all discharge piping and fittings with chlorine or approved water piping disinfection process. from disinfection unit to point of use removes existing contaminants and gives the unit a clean start. Be sure to rinse with U.V. treated water. A proper flow control must be used to insure only the designated flow through the unit. Installation 1. All plumbing must conform to local codes 2. Location Selection If it is likely that supplementary water treatment equipment will be required, make certain adequate additional space is available. The AS-V series are always placed after the pressure tank and any other type of treatment devices (i.e. softeners, filters). It is recommended to use some form of pre-treatment, such as a cartridge filter, to improve the clearity of the water and to safely disinfect the plumbing system. Do not install any equipment closer to a water heater than a total run of 10 feet of piping between the outlet of the equipment and the inlet to the heater. 3. Water Line Connection 4. Quartz Sleeves and UV Lamps After mounting, install quartz sleeve, O-Ring, and bulb per instructions. Turn on the water slowly, check for leaks, and repair as needed prior to full service operation. NOTE: For more detail on installation, cleaning and maintenance of the UV Lamps and Quartz Sleeves, see page 7 of this manual. NOTE: Once the system has been pressure check for leaks, the system needs to be disinfection using the sanitation procedures. ( See page 6 for instructions.) 5. Electrical Connection Remove twist tie from cord set and extend cord to its full length. Plug into socket that will accept 3-prong. Be sure the electrical outlet is not controlled by a wall switch. Turn power on and set electronic controls to current time of day (refer to user quick reference guide for setup instructions).if hard wiring electrical power make sure you review the wiring diagram and have electrical work done by a licenced electrician. WARNING: 1. Always disconnect electrical power to any U.V. unit before servicing. 2. Under no circumstances should personnel look at a U.V. lamp in operation (EXCEPT through an external Site Port lens located on the outside of the unit). 3. U.V. Disinfection units must always be properly grounded. Close main water supply valve. Open faucets to relieve water pressure and drain system. Mount the equipment into installation position. Assess the installation (i.e. type of pipe, size of lines, etc.) and obtain necessary plumbing fittings for installation. Use Teflon tape on all threaded connections and avoid over tightening. WARNING: If your piping system is subject to impulse pressure resulting in a water hammer condition, a surge tank or other means must be provided to remove this condition; otherwise, this extreme shock pressure condition may rupture or fracture the quartz sleeve. 4 Aqua Treatment Service, Inc. 2014 www.aquat.com

Installation Diagram Enlarged view of outlet with Thermal Relief Valve System Controls Thermal ReliefValve Optional-located on UV outlet Lamp Connection Housing Water influent Water effluent Pre-Filter Type of filter will depend on system requirements. UV Sensor Port Shut-off Valve Test Port UV Chamber Shut-off Valve Thermal Relief Drain Line Inlet Thermal Relief drain line and Sanitary Drain Optional with Thermal Relief valve www.aquat.com Aqua Treatment Service, Inc. 2014 5

Sanitation Procedure IMPORTANCE OF DISINFECTING A WATER SYSTEM: Every new well, or existing water supply system that has been disrupted for service or repair, should be disinfected before it is returned to use. Water in the well and storage tank should be treated with a strong chlorine solution or approved disinfection process to destroy disease organisms. All pipelines and fixtures in the distribution system should be rinsed and flushed with chlorinated water. Upon installation of a U.V. disinfection unit or bulb replacement service, disinfection with chlorine to initially flush the system is recommended to assure line sanitation prior to U.V. start up. The source of chlorine can be ordinary liquid laundry bleach (about 5.25% available chlorine). The quantity required depends on the volume of water to be treated. The United States Environment Protection Agency (EPA) indicated that about 100 parts of chlorine, by weight, mixed in a million parts of water will destroy essentially all water-borne disease organisms. WARNING: 1. Always follow the sanitizing procedure required by applicable state or local laws. 2. Chlorine may break loose iron deposits, slime and organic material. This material will make the water run colored. The material broken loose may plug pump screens. Do not continue to run pump if water doesn t flow. 3. The high level of chlorine required to sanitize a water system is corrosive to most metals and chlorine solution must not be allowed to remain in water system more than 36 hours before being completely flushed from system. 1. Systems With Pre-filter Turn off water. Unscrew Sump, remove filter and fill sump with liquid chlorine or standard bleach. Reattach sump to filter head. Turn water supply on. Go to each cold water line and run the water untill the chlorine is detected. Once chlorine is detected, turn the running water off. Allow chlorine to sit in plumbing for 30 min. To flush chlorine from system, run water at each faucet for several min. After system has been completely flushed, reinstall the filter and perform a bacteriological analysis on the water following all applicable procedures. 2. Systems With No Pre-filter Turn off water. Drain UV Chamber and remove quartz sleeve. Add chlorine through opening down into chamber. (approx 1 qrt.) Reinstall quartz sleeve. Turn water supply on. Go to each cold water line and run the water untill the chlorine is detected. Once chlorine is detected, turn the running water off. Allow chlorine to sit in plumbing for 30 min. To flush chlorine from system, run water at each faucet for several min. After system has been completely flushed, perform a bacteriological analysis on the water following all applicable procedures. 6 Aqua Treatment Service, Inc. 2014 www.aquat.com

Maintenance QUARTZ SLEEVE: Installation of the Quartz Sleeve: Always handle quartz sleeves carefully to prevent breaking or chipping. The quartz sleeves are to be clean and free of fingerprints before installing. Remove the compression nut. Install the quartz sleeve through the hole in the stainless steel top plate. Install the O-Ring down over and around the Quartz Sleeve. Place the retaining ring (with ark facing up) over the O-Ring and Quartz Sleeve. Hand-tighten each compression nut to form a compression seal around the Quartz Sleeve. Avoid over tightening the nuts, which may cause a fracture on the end of the Quartz Sleeve. Under normal operating conditions, hand-tightening will provide a 100 psi seal. Do not use any devices to tighten end nuts. Repeat this procedure for the remaining Quartz Sleeves in the chamber. After you have tightened the compression nut and all other plumbing connections, open the outlet valve. Slowly open the inlet valve and flush out all remaining air. Then close the outlet valve and slowly open the inlet valve fully. Check the unit for leaks. If you find a leak at the compression nut, tighten the nut further. If the leak continues, drain the unit and inspect the quartz O-Ring and Quartz Sleeve for proper seal. Once you complete checking the unit, reassemble O-Ring, retaining ring and gland nut. Repressurize the unit and check again. UV LAMPS: Installation of the UV Lamps: **DO NOT PUT POWER ON AT THIS TIME!** CAUTION: Never look directly at an operating U.V. lamp. Never operate a U.V. lamp outside the disinfection chamber. Make sure unit is unplugged when installing or servicing ultraviolet lamp. Remove any paper tabs on the U.V. lamp and avoid allowing fingerprints and other debris to deposit. Carefully place the lamp inside the quartz sleeve leaving enough space to connect the socket connector to the lamp pins. Requirements for Cleaning the UV Lamps: The U.V. lamp is rated for 12,000 hours of continuous use. After this period of time, the U.V. lamp has undergone a photochemical change. While the lamp will not normally be burned out, the lamp quartz may no longer emit the 254-nm shortwave U.V. to effectively kill bacteria. Failure to replace the U.V. lamps every 12,000 hours may cause bacteriological breakthrough. Should the use of the disinfection unit be intermittent, in no case should the U.V. lamp be used for more than 16 months regardless of the number of hours of operation due to normal shelf life degradation of the U.V. bulb. Changing the quartz sleeve should be done at the same time U.V. lamp replacement is scheduled. Requirements for Cleaning the Quartz Sleeve: As water passes through the U.V., minerals, debris and other matter in the water may deposit onto the Quartz Sleeve. After sufficient film has formed on the Quartz Sleeve, the ability of the ultraviolet germicidal rays to pass though the Quartz Sleeve and into the water may be impaired. Therefore, it is necessary to determine a cleaning schedule for the Quartz Sleeve. The frequency will depend on the specific type of water conditions. If the water has been processed through deionization, reverse osmosis, or is distilled, cleaning may be required only once per year. If untreated water is used, the cleaning frequency will vary. A minimum of once yearly is standard recommendation for cleaning and lamp replacement. Your specific situation will vary the frequency time according to the water quality of the home or facility application. It is recommended that your water supply be tested periodically through your local health department or approved certified laboratory. Maintenance Schedule: Replace UV Lamps, Quartz Sleeves and O-Rings 16 months. This will insure the propre function of the unit. Cleaning the Quartz Sleeve: To clean the Quartz Sleeve, turn off the water flow to the disinfection unit, turn power off, and disconnect the electrical service to the lamp pins. Carefully remove the U.V. lamp. Loosen the compression nuts with O-Rings and remove the Quartz Sleeve while draining the water from the chamber. The Quartz Sleeve may then be washed with a mild soap and hot water solution and rinsed clean with hot water. Should this be insufficient to clean the Quartz Sleeve, a mild acid or an approved cleaning solution may be used (i.e. vinegar). Be certain to follow all recommended safety and handling procedures on the acid container. It is important to handle the Quartz Sleeve with care to prevent breakage. Make certain that all finger prints are wiped clean before reinstalling (see installation of the Quartz Sleeve). Replace O-Rings every time a Quartz Sleeve is cleaned or replaced. www.aquat.com Aqua Treatment Service, Inc. 2014 7

Electronic Controls Setup 1 2 3 4 Key-Pad 1. System Status Indicater Lamp 2. Alarm Status Indicater Lamp 3. System Display Screen 4. Curser Direction Keys 5. Escape / Back Key 6. Enter Key 5 6 8 Aqua Treatment Service, Inc. 2014 www.aquat.com

Standard System Setup (No-Probe) www.aquat.com Aqua Treatment Service, Inc. 2014 9

Electronic Controls Setup 1 2 3 4 Key-Pad 1. System Status Indicater Lamp 2. Alarm Status Indicater Lamp 3. System Display Screen 4. Curser Direction Keys 5. Escape / Back Key 6. Enter Key 5 6 10 Aqua Treatment Service, Inc. 2014 www.aquat.com

Monitor System Setup www.aquat.com Aqua Treatment Service, Inc. 2014 11

Parts Breakdown - AS-V16 12 Aqua Treatment Service, Inc. 2014 www.aquat.com

Parts Breakdown - AS-V26 www.aquat.com Aqua Treatment Service, Inc. 2014 13

Parts Breakdown - AS-V36 14 Aqua Treatment Service, Inc. 2014 www.aquat.com

Parts Breakdown - AS-V38 www.aquat.com Aqua Treatment Service, Inc. 2014 15

Parts Breakdown - AS-V48 16 Aqua Treatment Service, Inc. 2014 www.aquat.com

Parts Breakdown - ATS-186K-10 www.aquat.com Aqua Treatment Service, Inc. 2014 17

Parts Breakdown - ATS-186K-20 18 Aqua Treatment Service, Inc. 2014 www.aquat.com

Parts Breakdown - ATS-186K-40 www.aquat.com Aqua Treatment Service, Inc. 2014 19

Parts Breakdown - ATS-186K-60 20 Aqua Treatment Service, Inc. 2014 www.aquat.com

Parts Breakdown - ATS-186K-80 www.aquat.com Aqua Treatment Service, Inc. 2014 21

Parts Breakdown - ATS-186K-120 22 Aqua Treatment Service, Inc. 2014 www.aquat.com

Parts Breakdown - ATS-186K-240 www.aquat.com Aqua Treatment Service, Inc. 2014 23

Parts Breakdown - ATS-186K-480 24 Aqua Treatment Service, Inc. 2014 www.aquat.com

Parts Breakdown - Electronic Control System Monitor Parts Breakdown Front View 1. System Status Lamp 2.Alarm Status Indicator Lamp 3. System Display Screen 4.Curser Direction Keys 5. Escape/Back Key 6. Enter Key 7. Off/On Power Switch 8. Fuse Bottom View: 9. UV Probe Connection 10. Flow Meter Connection 11. RS232 Connection for Software 12. Shutoff Solenoid Power Plug-in 13. Power Cord 14.Pressure Siwtch Connection 15. Cooling Fan 16. Cables Leads to Skid Unit www.aquat.com Aqua Treatment Service, Inc. 2014 25

Specifications AS - V16 1 0.17 1 1 36 x 10 x 17 304 SS 35 lbs. AS - V26 2 0.33 2 1.5 36 x 10 x 17 304 SS 45 lbs. AS - V36 3 0.49 3 2 36 x 10 x 17 304 SS 60 lbs. AS - V38 3 0.49 3 2 36 x 12 x 19 304 SS 98 lbs. AS - V48 4 0.66 4 2 36 x 12 x 19 304 SS 105 lbs. AS - V16 59 44 63 21 6 AS - V26 115 86 121 40 12 AS - V36 167 125 175 58 17 AS - V38 233 175 246 82 24 AS - V48 305 228 321 107 32 Clear Fresh Water at 94% UVT DI / RO Water at 99% UVT DI / RO Water (-03D) at 99% UVT DI / RO Water (TOCR) at 99% UVT 220V Specs are available upon request ATS - THERM ATS - RLCM ATS - STAND ATS - 254P - RLC ATS - ESP ATS - SP ATS - 304NCB ATS - 220V ATS - LT ATS - STC ATS - MW ATS - 316 SS Adjustble Settings Thermistor Overheat Safety Control Remote PLC Monitoring Connection Control Box Mounting Stand (powder coated) UV Intensity Monitor / NIST Traceable Calibrated UV Sensor Energy Saver Pacing 1/4 Sample Ports on Inlet / Outlet Riser 304 SS #4 Brushed Finish on Nema 4 Type Control Box 220-240 Volt / 50-60 Hz Electrical Components UV Light Traps on Inlet / Outlet Sanitary - Tri - Clamp Fittings Manual Quartz Sleeve Wiper 316 Stainless Steel Wetted Parts 26 Aqua Treatment Service, Inc. 2014 www.aquat.com

Specifications ATS-186K-10 2.32 2 1 36 x 10 x 17 304 SS 10 gpm Call for Price ATS-186K-20 4 1.32 4 1 36 x 12 x 19 304 SS 20 gpm Call for Price ATS-186K-40 5 1.66 5 1 1/2 36 x 14 x 21 304 SS 40 gpm Call for Price ATS-186K-60 6 1.94 6 2 36 x 16 x 23 304 SS 60 gpm Call for Price ATS-186K-80 8 2.6 8 2 36 x 16 x 23 304 SS 80 gpm Call for Price ATS-186K-120 10 3.2 10 3 36 x 18 x 25 304 SS 120 gpm Call for Price ATS-186K-240 12 4.2 12 4 72 x 18 x 25 304 SS 240 gpm Call for Price ATS-186K-480 10 3.2 10 4 72 x 18 x 25 304 SS 480 gpm Call for Price ATS -STAND Control Box Mounting Stand (powder coated) Call for Price ATS -THERM Adjustable Setting Thermistor Overheat Safety Control Call for Price ATS - ESP Energy Saver Pacing Call for Price ATS - SP 1/4 Sample Port on Inlet/Outlet Riser Call for Price ATS - 304NCB 304 SS #4 Brushed Finish on Nema 4 Type Control Box Call for Price ATS - LT UV Light Traps on Inlet/Outlet Call for Price ATS - STC Sanitary-Tri-Clamp Fittings Call for Price ATS - MW Manual Quartz Slaave Wiper Call for Price ATS - 316 SS 316 Stainless Steel Wetted Parts Call for Price 220V Specs are available upon request. System Options installed on Pre or Post Piping are done by Contractor and NOT factory. C.F.C. is Call For Cost See page 30 for replacement part. www.aquat.com Aqua Treatment Service, Inc. 2014 27

Dimensions OVERAL DIMENSIONS FOR SAPCE REQUIREMENTS Model AS-V 36 NOTE: Dimensions will very slightly with other models. 11.25 11.25 *6 *6 47.5 35.055 47.5 37.5 2.445 5 5 *6 is with 2 pipe, hight may change with larger pipe size. This will also affect the Overall Hight. 28 Aqua Treatment Service, Inc. 2014 www.aquat.com

Troubleshooting www.aquat.com Aqua Treatment Service, Inc. 2014 29

Warranty 30 Aqua Treatment Service, Inc. 2014 www.aquat.com