Classix 6" 6" Round Downlight

Similar documents
Performance Chart Electrical Data

Classix 6" 6" Round Lens Downlight

Cylindrix III Mini. 3.5" Round Surface Canopy

Classix 6" 6" Round Lens Wall Wash

Classix 6" 6" Round Adjustable C3

Classix 6" 6" Round Lens Wall Wash

Classix 6" 6" Round Lens Wall Wash

Classix 6" 6" Round Adjustable C3M

Classix 6" 6" Round Adjustable C3

Product Overview. Fixture Type. Performance Chart. Wattage. Electrical Data 23W System Watts Amps

Evoke Square Downlight

Hornet HP. Round Glass Downlight

Evoke Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Evoke 2.9" HP. 2.9" Square Downlight

Evoke Round Adjustable C3

Hornet HP. Square Glass Downlight

Evoke Square Downlight

Evoke Round Downlight

Evoke 2.9" HP. 2.9" Round Lens Wall Wash

Essenza. Square Downlights

Essenza. Round Downlights

Performance Chart Electrical Data

Evoke Square Adjustable HP

Performance Chart Electrical Data

Evoke Square Adjustable C3M

Performance Chart Electrical Data

Evoke Square Adjustable HP

Velato. Recessed Slot Adjustable Multiples

Hornet HP. Semi-Recessed 4-Light Square Multiple

Hornet HP. Recessed 4-Light Square Multiple

approved to UL standard as tested by CSA Damp location Wet location option (adds clear lens and trim gasket) IC/AT rated (27w only) 4 11 / / 8

Performance Chart Electrical Data

Performance Chart Electrical Data

Murro HP. 3.5" Round Surface Canopy Wall Wash

Etch 2' x 2' Recessed LED

Grüv Flare Regressed. Recessed Linear LED

Grüv Flare Regressed. Recessed Linear LED

HORNET-HP-R- A14-3 3LT LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Fino Healthcare. Asymmetric Wall Mount Indirect LED

Fino. Asymmetric Wall Mount Indirect LED

Linea 1.5. Linear Direct Wall Wash LED

IHOL-8DS / ISD802 8 Gravity LED Square Downlight with Regressed Lens - Wet Location

Linea 2.5. Linear Indirect LED

Catalog # Project. Comments. Prepared by

Fixture Summary (see following pages for more information) Performance Chart Wattage Per Foot. Standard Patterns " "

4 LED Recessed Adjustable. Energy efficient, stylish downlighting for residential and commercial applications

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) F Frosted S Solite (provided standard) RETROFIT

RA406930NFLWH 4" Led Adj Gimbal 30K 120V Narrow FLD

Ordering Example: Specify trim code and housing code to order: Example : 1020W - B LRTD M2-27KS NCSM - 277V - DIML2 - CB27

Linea 2.5. Linear Direct/Indirect LED

HALO. 2700K nominal. 3000K nominal. RA4 LED Very Wide Flood (VWFL)

IHOL-6DS / ISD600 6 Gravity LED Square Downlight

USAI. BeveLED2.1. BeveLED. COLOR SELECT Covered By US Patents 8,581,520 and 8,456,109 DOWNLIGHT 1 REGRESS DOWNLIGHT DEEP REGRESS DOWNLIGHT.

IHOL-6DR / IRD600 6 Gravity LED Downlight

Fahrenheit Recessed LED Downlight Fire and Sound-Rated New Construction 4, 5, 6 Aperture

IHOL-4DR / IRD400 4 Gravity LED Downlight

DRD5S & SurfaceFrame Alt/EM 18" Linear Surface Mount LED Area Light

DRD5S & SurfaceFrame Alt/EM Surface Mount LED Downlight

PROJECT INFORMATION DELIVERED PERFORMANCE. BeveLED REGRESS DOWNLIGHT DELIVERED PERFORMANCE. BeveLED 2.1 WGD DEEP REGRESS DOWNLIGHT

IHOL-S4DR / IRDS400 4 Gravity LED Shallow Downlight

80 Watts FLANGE FINISH

Linea 3.5. Linear Direct/Indirect LED

TROFFER RETROFIT KIT (TRK)

PROJECT INFORMATION DELIVERED PERFORMANCE. Performance based on: 3000K, 50 beam

WARRANTY LED ECO PANEL.

BEVEL STYLE LENS B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

WARRANTY LED ECO PANEL.

LED ECO PANEL.

LED ECO PANEL.

LED ECO PANEL.

DIMMING: (optional) Multiple dimming drivers available. See compatibility chart attached.

FLANGE FINISH VOLTAGE. NC New Construction CP Chicago Plenum 2 IC Insulation-Contact Rated / Airtight 2 120V 277V

diode led HYDROLUME 24V LED Strip Light 24VDC IP65

LED ECO PANEL.

10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #) (Leave blank for AB1 and AC1 Bevel Styles)

FLANGE FINISH. New Construction, Narrow Width IC Insulation-Contact Rated / Airtight 2 40KS 4000K, 80+ CRI CP Chicago Plenum beam beam

3.75 Gyro Shift Multiples Single Head

Ordering Example: Specify trim code and housing code to order: Example : 1251W - B LRTW M2-27KS - NCSM - 277V - DIML2 - CB27

PROJECT DATE FLANGE FINISH

CRENSHAW. Board and driver LED standard systems for ceiling mounts. Crenshaw LED. Standard Ceiling Options

LIGHT CHANNEL TRIM 1.6

Project: Comments: Prepared By: Control. Code Fixture & Trim D3 Wall Wash, Round. Platform & Control Wide Gamut, Tunable

PROJECT INFORMATION B1 BEVEL FINISH. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

USAI. BeveLED 2.1 International Dimming Compatibility. Lighting River Road New Windsor, NY

PROJECT INFORMATION. DATE Covered By US Patent 8,456,109 and 8,581,520

OPTIONAL LENS 2 FLANGE FINISH

LUMINAIRE ID SIZE CENTER OPTICS SIDE OPTICS LIGHT SOURCE CRI LUMEN PACKAGES COLOR TEMP. VOLTAGE. LED - high performance LED 80-80CRI 90-90CRI

LM Series LED Architectural Downlighting HIGH LUMEN OUTPUT RECESS / SURFACE MOUNT GREEN ENERGY EFFICIENT LIGHTING

P5500 LED Architectural Downlighting

diode led EMERY Ensemble Suspended Linear LED Fixture AVAILABLE IN: 24VDC DI - - SPECIFICATIONS SPECIFICATION SHEET Item # Project

DOWNLIGHT 800/1200/1500 LUMEN ROUND APERTURE REMODEL AX2 DR

INTERNATIONAL. Ordering Example: Specify trim code and housing code to order: Example : 3253INT - B LRTW WGD1-2722KS - INT10 - CGBO

DATE TYPE 40 DELIVERED PERFORMANCE

Type: Project : Luminaire characteristics: Source: Lumen maintenance: Optics: Material: Mounting: Electrical: Finish: Weight:

PROJECT INFORMATION PROJECT DATE. 9 Watts 12 Watts 16 Watts 24 Watts 33 Watts

Ivalo Lumaris LED Linear Lighting

LIGHT CHANNEL.3 SURFACE MOUNT COMPLETE FIXTURE

PROJECT INFORMATION. 10 White 13 Statuary Bronze 21 Black 28 Metalized Grey RAL Custom Color (specify RAL #)

Transcription:

Features The Classix downlight shines new light on your bigger jobs. ith a unique Amerlux blend of architectural form and function, Classix performs perfectly in large retail and commercial spaces. Designed for higher ceilings, this downlight features high output, various beam options, and an optional commercial grade lens. Product Overview Type: Recessed Round Downlight attage: 25, 34,, 52 umen Output: 3,563 max; m/ (52 data) CBCP: 19,788 max (52 data) Color Temp: 2700K, 3000K, 3500K, 4000K, CRISP CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) + typ. (2700K, 3000K) Crisphite ED available : TRIAC & EV (120V/277V) - 5% Dim utron A Series (120V/277V), 3-wire/EcoSystem Hi-lume - 1% dim 0-10V (120V/277V) - 1% Dim DAI dimming Fixture Type Round New Construction Remodeler Trim Yes Yes Yes Yes Performance Chart atts Delivered umens P CBCP Color Temp 25 1,970 79 11,136 3000K-83 34 2,530 74.4 14,049 3000K-83 3,207 71.2 17,809 3000K-83 52 3,563 68.5 19,788 3000K-83 Data is based on 52 3000K-83 IES files available on website Data is Spot optic. See pages 5-6 for other beam spreads 5 Title 24 Compliant Electrical Data 25 34 52 System atts Amps System atts Amps System atts Amps System atts Amps 120V 25 0.21 34 0.28 0.38 52 0.43 277V 25 0.09 34 0.12 0.16 52 0.19 Electronic constant current ED driver IT-2082 03/16/18 Page 1 of 8

Housing/Frame Ordering Information 1 2 3 4 5 1 Model For New Construction CX-R6-NC-A17 (New Construction) For Existing Ceilings CX-R6-REM-A17 (Remodeler) 4 (for non-dimming, select E/TE option) E/TE - TRIAC/EV dimming HIUME-A - utron Hi-lume A Series, 3-wire/EcoSystem, Hi-lume, 1% dim (25 & 34 only) 0-10V - 0-10V dimming; 1% dim DAI - DAI dimming, 1% dim (25, 34 & 46 only) 2 attage 25 34 52 5 Options/Accessories EM - emergency battery pack with remote test switch (not available for use with REM option) 3 Voltage 120 277 Trim Ordering Information CX-RD6-A17 1 2 3 4 1 2 3 4 Model CX-RD6-A17 Finish SD - semi-diffuse, white flange SDC - semi-diffuse, clear flange (flange finish matches cone finish) Beam Spreads SP - spot, 15 F - flood, 25 F - wide flood, 40 Color Temp 83 CRI + CRI 27-2700K-83 279-2700K-+ CRISP - Crisphite 30-3000K-83 309-3000K-+ 35-3500K-83 40-4000K-83 The "A" refers to the sequential revision in a year and "XX" refers to the year of update. Updates coincide with improved performance while not changing the overall fixture aesthetic and are reflected in the published performance data. Please contact your Amerlux representative for explanations of changes. IT-2082 03/16/18 Page 2 of 8

Specifications Application Retail, commercial and hospitality ambient lighting Construction 20 ga. galvanized steel frame 18 ga. galvanized steel splice housing and hanger brackets (not for Remodeler version) Passive cooling Extruded aluminum heat sink Optical Spun aluminum semi-diffuse aperture cone Spun aluminum upper reflector ED Color Temp Options: 2700K, 3000K, 3500K, 4000K CRI: 83 typ. (2700K, 3000K, 3500K, 4000K) + typ. (2700K, 3000K) Crisphite* ED available (see description below) R9 Values: 11 (83 CRI), 55 (92 CRI) Binning: 3 MacAdam (SDCM) ife: 50,000+ hrs, > 70% of initial lumens at 50,000 hrs *Crisphite: Crisphite Technology delivers the warmth of colors expected from a high CRI solution but also creates the natural crisp white color that is pleasing to the eye. It creates the most impactful lighting ever available, by revealing the richest whites and vibrant colors that pop. Electrical attage: 25, 34,, 52 Electronic constant current ED driver, 120V or 277V input This product complies with IEEE C62.41 for surge endurance up to 2.5KV. Amerlux recommends using additional surge protection with this unit (supplied by others), surge and over voltage damage is not covered under warranty. s E/TE - eading Edge, TRIAC, forward phase/trailing Edge, EV, reverse phase (standard) 0-10V, utron and DAI systems also available See pages 7-8 for more dimming information Finish (Trim) et paint Mounting For use in T-grid or sheetrock ceilings Adjustable hanger bars included (14 ½ - 25 std.) (32-48 Adjustable hanger bars available, consult factory) Certifications CSA damp as tested to U 1598 standards Damp location arranty 5 year limited warranty IT-2082 03/16/18 Page 3 of 8

Classix Round ens Downlight: New Construction 10 15 /16 15 1 /8 4 3 /8 9 5 /8 13 3 /16 4 3 /4 14 1 /2 min - 26 max 6 7 7 /16 Ceiling cut out: 7 dia. 1 Remodeler Ceiling 3 7 /8 9 3 /16 9 5 /8 4 15 /16 20 3 /16 5/8 6 7 7 /16 3 3 /16 Ceiling cut out: 7 dia. IT-2082 03/16/18 Page 4 of 8

FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MUTIPYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES file on website) attage: 25 34 Factor: 1.0 1.4 1.8 FOR 52 DATA SEE NEXT PAGE CCT: 2700K-83 3000K-83 3500K-83 4000K-83 2700K-+ 3000K-+ CRISP Factor: 0.96 1.0 1.02 1.04 0.80 0.83 0.65 25 ED (3000K-83) Spot Distribution T #1026868 umens: 1,970; 79 m/ CBCP: 11,136 Flood Distribution T #1026867 umens: 1,866; 74.9 m/ CBCP: 6,2 ide Flood Distribution T #1026866 umens: 1,951; 78.3 m/ CBCP: 4,046 2500 1500 1000 5000 3000 2000 00 10000 00 00 3000 4000 0 15 30 0 15 30 0 15 30 0 11136 5 9304 15 2887 25 440 35 93 39 0 62 5 5927 15 3221 25 597 35 105 37 0 4046 5 3998 15 30 25 1114 35 197 37 Application Data: D IDE FOOD FOOD SPOT 0 o Aiming Angle Horizontal Footcandles D 5.0 444 1.6 1.6 7.5 198 2.7 2.7 10.0 112 3.4 3.4 12.5 72 4.3 4.3 D 5.0 252 2.6 2.6 7.5 112 3.8 3.8 10.0 63 5.1 5.1 12.5 41 6.4 6.4 D 5.0 162 3.5 3.5 7.5 72 5.2 5.2 10.0 41 7.0 7.0 12.5 26 8.7 8.7 D 30º CB Notes and Definitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. =Footcandles on floor or wall at center beam aiming location. =Effective Visual Beam length in feet (50% of maximum footcandle level). =Effective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 30 CB IT-2082 03/16/18 Page 5 of 8

FIXTURE DATA: (Complete photometric data (.ies format) available upon request) MUTIPYING FACTORS: (Multiplying Factor is based on 3000K-83 120V IES file on website) attage: 34 52 Factor: 0.71 0. 1.0 FOR 25 DATA SEE PREVIOUS PAGE CCT: 2700K-83 3000K-83 3500K-83 4000K-83 2700K-+ 3000K-+ CRISP Factor: 0.96 1.0 1.02 1.04 0.80 0.83 0.65 52 ED (3000K-83) Spot Distribution T #1026865 umens: 3,563; 68.5 m/ CBCP: 19,788 Flood Distribution T #1026863 umens: 3,7; 66.4 m/ CBCP: 11,614 ide Flood Distribution T #1026864 umens: 3,7; 69.3 m/ CBCP: 7,373 5000 2500 10 10000 5000 3500 15000 20000 00 10000 5250 7000 0 15 30 0 15 30 0 15 30 0 119788 5 16499 15 5520 25 813 35 173 73 0 11614 5 10971 15 5987 25 1089 35 193 68 0 7373 5 7315 15 5677 25 2088 35 350 70 Application Data: D IDE FOOD FOOD SPOT 0 o Aiming Angle Horizontal Footcandles D 5.0 7 1.6 1.6 7.5 352 2.7 2.7 10.0 198 3.4 3.4 12.5 127 4.1 4.1 D 5.0 465 2.6 2.6 7.5 207 3.8 3.8 10.0 117 5.2 5.2 12.5 6.5 6.5 D 5.0 296 3.5 3.5 7.5 132 5.3 5.3 10.0 74 7.0 7.0 12.5 48 8.9 8.9 D 30º CB Notes and Definitions: Beam spread is to 50% center beam candlepower (CBCP). D=Distance to floor or wall. =Footcandles on floor or wall at center beam aiming location. =Effective Visual Beam length in feet (50% of maximum footcandle level). =Effective Visual Beam width in feet (50% of maximum footcandle level). CB=Distance across or down to center beam location. 30 CB IT-2082 03/16/18 Page 6 of 8

DIMMING COMPATIBIITY: Amerlux Classix fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMATION BEO IS FOR IRED DIMMERS ONY. FOR IREESS DIMMERS, CONSUT FACTORY --- TRIAC (Forward Phase) DIMMING (Standard) Utilizes Standard incandescent dimmers that are in wide use in installations across the US. Best for retrofit applications where TRIAC dimmers are installed. 120V or 277V* Dims down to less than 5% light output (most cases) Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! Must meet dimmer Minimum oad Requirements per dimming manufacturer all Box (Incandescent Style, attage as required) utron Diva utron Vareo utron Nova-T utron Skylark utron Maestro TRIAC iring Diagram TRIAC hite Green utron GP Panel utron Grafik Eye QS EV - Electronic ow Voltage (Reverse Phase) DIMMING (Standard) Utilizes specialized EV dimmers. Best for New Construction applications EV iring Diagram 120V or 277V* Dims down to less than 5% light output (most cases) EV Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! Must meet dimmer Minimum oad Requirements all Box (EV Style) utron Diva utron Nova-T utron Maestro eviton Surslide utron Vareo utron Skylark eviton Vizio hite Green utron GP Panel with PHPM-PA Interface utron Grafik Eye QS with PHPM-PA Interface 0-10V - DIMMING (-0-10V Option) Integrates into a variety of building management and daylighting controls 0-10V iring Diagram 120V or 277V* Dims down to 1% light output Requires interface to turn off power to driver Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! 0-10V Gray Purple hite Green 0-10V (-) 0-10V (+) Switched Hot all Box utron Diva - DVTV with PP- 120H Interface eviton Renoir II 0-10v utron Grafik Eye with GRX-TVI Interface * is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimming installation instructions for 277V wiring diagrams. IT-2082 03/16/18 Page 7 of 8

DIMMING COMPATIBIITY: Amerlux Classix fixtures are compatible with all major dimming protocols prevalent in the United States. Please see below for general compatibilities and wiring diagrams. Amerlux recommends testing your unique dimming configuration as the exact full configuration (Dimmer, Fixture Quantity, Voltage, etc) may affect dimming performance. --- NOTE: INFORMATION BEO IS FOR IRED DIMMERS ONY. FOR IREESS DIMMERS, CONSUT FACTORY --- UTRON A-SERIES HI-UME / ECOSYSTEM (-HIUME-A Option) Integrates into utron EcoSystem building management 3-ire iring Diagram 120V or 277V* Dims down to less than 5% light output May use 3-ire or EcoSystem Consult manufacturer for installation instructions - DO NOT SHARE NEUTRAS! Cap unused ECOSYS wires 3-ire Phase Purple Stripe Purple Orange hite Green E1 E2 Dimmed Hot Switched Hot all Box (3-ire Fluorescent) DIVA Maestro Nova T Vareo utron EcoSystem compatible controls EcoSystem Digital iring Diagram E2 E1 ECOSYS Bus EcoSystem Purple Stripe E1 Purple E2 (Cap off Orange wire) Orange Dimmed Hot Switched Hot hite Green DAI DIMMING (-DAI OPTION) Digital control protocol allows individual fixture control DAI iring Diagram 120V - 277V* Dims down to 1% light output in most cases all Box (3-ire Fluorescent) eviton CD250 ler DAI DAI Bus Purple Purple/T hite Green Dynalite Fifth ight * is 277V dimmable with appropriate dimmer (by others). All provided wiring diagrams show 120V wiring colors and method. Please refer to 277V dimming installation instructions for 277V wiring diagrams. IT-2082 03/16/18 Page 8 of 8