Fire Sprinklers The Ultimate Fire Fighters Eric Skare

Similar documents
What Builders Need to Know about Residential Sprinkler Design

What You Need to Know about Residential Sprinkler Design

The Role of Home Fire Sprinklers in CRR

HOME FIRE SPRINKLER SYSTEMS. the future of fire safety here today

Illinois Fire Safety Alliance

Zurn Pex, Inc. Residential Fire Protection Presentation. PEX Plumbing, Radiant Heating and Residential Fire Protection Systems

HOME FIRE SPRINKLER SYSTEMS. fire safety. the future of. here today

Fire Protection Coffee Break Training August 2016

Review of Residential Fire Sprinkler Systems for One- and Two-Family Dwellings

What builders need to know about home fire sprinklers

RESIDENTIAL MULTI-USE FIRE SPRINKLER SYSTEMS PERMIT SUBMITTAL REQUIREMENTS

PROTECT WHAT YOU VALUE MOST

Analysis of the Economic and Life-Saving Impact of a Residential Fire Sprinkler Requirement in Connecticut

2009 International Residential Code Draft of New Fire Sprinkler Related Requirements

Residential Fire Sprinkler Systems

Residential Fire Protection PWD Experience

The Benefits of Home Fire Sprinklers IN ONE- AND TWO-FAMILY HOMES

Fire Sprinklers. Residential. What could you save from the ravages of fire if you had a firefighter 24/7 in every room of your home?

The Benefits of Home Fire Sprinklers

VILLAGE OF DOWNERS GROVE Report for the Village Council Meeting

State Board of Examiners of Plumbing, Heating & Fire Sprinkler Contractors. Residential Fire Sprinkler Inspections

General Kitchen, Bath & Bedroom Remodeling Notes County of Marin, Building Inspection Division

The Benefits of Home Fire Sprinklers IN ONE- AND TWO-FAMILY HOMES

Center for Life Safety Education

Sprinkler Permit Applications

Application of the New Italian Fire Safety Code (D.M. 3 agosto 2015) to Case Study 3 Mall. Enrico Danzi Luca Fiorentini Luca Marmo Vincenzo Puccia

Potential Savings of Tax Dollars

Building Fire Safety in New York City s Existing Office Buildings

FAQ. (Frequently Asked Questions) What is required to convert my unfinished basement to finished space?

SCHULTE & ASSOCIATES Building Code Consultants 880D Forest Avenue Evanston, IL /

Passive fire protection. 6 Passive fire protection. 6.1 Fire compartmentation. Passive fire protection

Sprinkler Systems, The Next Step. John Dailey Fire Marshal Peachtree City Fire & Rescue

BRE: Stay-put or Evacuate? Carl Sherwood BRE Fire Safety Group 22 nd July Part of the BRE Trust

Real-scale dwelling fire tests with regard to tenability criteria

NZS 4517:2010. New Zealand Standard. Fire sprinkler systems for houses. Superseding NZS 4517:2002 NZS 4517:2010

Module 7. Control of Smoke & Highlights of Code Requirements

MISSION To prevent the loss of life and property and to reduce injury by providing emergency response, education and prevention services.

Informational Bulletin

PROPOSED CODE CHANGES FOR REVIEW BY THE FIRE CODE ACTION COMMITTEE

Established /10/2015. Doran Pruisner Dan Wood

Residential Fire Sprinklers

The Physical Environment Portal: Module 5, LS Leadership

MONTECITO FIRE PROTECTION DISTRICT

8.1. Fire and Heritage. The maintenance series. Information sheet. Guidelines on Fire Safety in Heritage Buildings

Mid Rise Timber Framing. Click here to start

An Overview of Extinguishing Systems for Computer Equipment

American Fire Sprinkler Association. An Introduction to the IBC and IFC

First Aspen Federal Regulation Set: K LSC 2000 Health Existing

HELP THEM PROTECT THEIR WORLD.

ATTIC FIRES. Part 2 LIGHT SMOKE SHOWING

UPHOLSTERED FURNITURE AND MATTRESSES IN NEW AND EXISTING BUILDINGS

Incident Summary (Reference # )

B. Galvanized-Steel-Sheet Sleeves: inch minimum thickness; round tube closed with welded longitudinal joint.

This document is a preview generated by EVS

Antifreeze Solutions and Automatic Fire Sprinkler Systems. March 12, 2013

Savard Labor & Marine Staffing, Inc. Fire Prevention Program Rev3/14

PLACES OF ASSEMBLY CHAPTER 17

1 Batterymarch Park, Quincy, MA Phone: Fax: M E M O R A N D U M

Unit 2 Fire Safety (Zone 1)

CAN/ULC-S INTEGRATED SYSTEMS TESTING OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

Objective 1: Describe fire alarm systems.

Commercial Flat Concealed Sprinkler, Pendent, Quick Response, Extended Coverage (Light Hazard) Model: RC-QR-EC, K-Factor: 5.

Data Sheet 4.24 Issue F

Residential Lead Free Flat Concealed Sprinkler, Pendent, Model: RC-RES, K-Factor: 4.9, SIN: SS8461

DCN: ENGINE COMPANY OPERATIONS CHAPTER 4 March 15, 1997 FIRE SCENE OPERATIONS

Rental Housing Initial Inspection Checklist Community Development Department 208 NW 1 st Ave., Faribault, MN

Uponor AquaSAFE system installation guide

January 1, 2014 Mandatory Effective Date

Chapter 17 Test. Directions: Write the correct letter on the blank before each question.

2012 SunTrust Center ERT Annual Review. 919 East Main St. Richmond, VA

Performance Metrics for First Responder Locating/Tracking Technologies

HOW COMMERCIAL FIRE PROTECTION SPRINKLER SYSTEMS REALLY OPERATE

Committee Input No. 28-NFPA 13R-2013 [ Global Input ]

Home Fires Are Common, Deadly and Preventable

ATTIC FIRES. Part 3 HEAVY SMOKE SHOWING

Celebrating 75 years of Schult excellence.

Iron Owl Rooftop Sprinklers

2007/2008 INTERNATIONAL RESIDENTIAL PLUMBING/MECHANICAL CODE COMMITTEE

Unit 2 Fire Safety (Zone 2)

Commercial Rules and Regulations

2016 Webinar Sponsors

APPENDIX H (DESIGN SUBMISSION CRITERIA)

CALIFORNIA MECHANICAL CODE OVERVIEW OF 2016 UPDATES CHANGES AND RAMIFICATIONS

Commercial Remodel/ Add On Rules and Regulations

Water Purveyor s Guide to 2006 Fire Sprinklers in Single Family Dwellings

Bringing Science to the Street: UL and Firefighter Safety Research By Stephen Kerber, PE, Director, UL Firefighter Safety Research Institute

Learn About Fires Every day, Americans experience the horror of fire but most people don't understand it.

Recommended Amendments to the 2015 International Existing Building Code North Central Texas Council of Governments Region

NFPA 101 Life Safety Code Culture change 2012

Statue of Liberty: A Risk Analysis

2012 B.C. Building Code Compliance Review (Division B Part 3)

CAN/ULC-S1001, INTEGRATED SYSTEMS TEST OF FIRE PROTECTION AND LIFE SAFETY SYSTEMS

U.S. Firefighter Disorientation Study Prepared by William R. Mora, Captain San Antonio Fire Department San Antonio, Texas.

CAN/ULC S Integrated Systems Testing of Fire Protection and Life Safety Systems and Fire Protection Commissioning

FIREJET V / 48V SMOKE SYSTEMS CE EN CERTIFIED

MECKLENBURG COUNTY FIRE MARSHAL S OFFICE

DEALING WITH FIRE SAFETY

SENJU SPRINKLER CO., LTD.

Fire & Life Safety Supplemental Rules & Regulations for New Construction & Significant Remodels

Draft FPA Australia Technical Specification for Public Comment FPAA101D DRAFT

Transcription:

Fire Sprinklers The Ultimate Fire Fighters Eric Skare

Presentation Description The residential fire problem has changed over the last several decades. Although some aspects have improved, fires in newly constructed and furnished homes can become deadly in as little as a few minutes. This presentation will provide an overview of why residential fire sprinklers are so effective, and so necessary in today s environment. New materials, design approaches, and applications will be highlighted to provide insight, awareness, and understanding of fire sprinkler systems. Learn how, and why, to incorporate this life saving technology into your cutting edge building designs. 2

Presenter Introduction - Eric Skare Eric Skare, product manager, fire safety for Uponor, is a certified fire protection specialist (CFPS), has been a volunteer firefighter since 2002, and is a principal member of the National Fire Protection Association (NFPA) Technical Committee on Residential Sprinkler Systems. He is actively involved in various industry associations including chairing the Fire Sprinkler committee for the Plastic Pipe and Fittings Association (PPFA) and serving on the Residential Committee and Future Leadership Committee for the National Fire Sprinkler Association (NFSA). 3

Learning Objectives The fire problem and the solution Fire sprinkler myths Emerging technologies 4

The Fire Problem

Flashover Flashover the point where everything in the room suddenly and simultaneously ignites Approximately 1,100 F to 1,500 F Can occur in just a few minutes 6

NOTHING SURVIVES FLASHOVER 7

Modern Furnishings 8

Open Floorplans Large open spaces High, vaulted ceilings Fewer doors Nothing to contain heat, smoke and toxic gases Fires grow and spread rapidly 9

Lightweight Construction Cost effective Light and strong Quiet Poor performance when exposed to fire Structural failure in as little as 5 minutes 10

Myth #1: Smoke alarms are enough to keep me safe 11

Smoke alarms just aren t enough anymore Occupants don t have time to get out of the home Flashover and structural collapse can occur in as little as just a few minutes Fire sprinklers are the solution 12

Fire Sprinkler Overview 13

Sprinkler Basics This threads into fitting This holds back the water This heats up and breaks when there is a fire This heats up and melts Water hits this - Water goes on the fire and removes the heat 14

Fire Sprinkler vs. Fire Hose Fire Sprinkler Fire Hose 150 gpm 15 gpm 15

Myth #2: When one goes off they all go off Myth #3: My house will get flooded if I burn the toast 16

Individually heat activated Will not activate by smoke 10-15 gallons per minute vs 150 gallons per minute Fire damage, firefighter damage, or A fire sprinkler controlling the fire when it is small 17

Codes and standards Sprinkler system installation requirements typically in accordance with NFPA (National Fire Protection Association) standards: NFPA 13 NFPA 13R NFPA 13D life safety Model building codes require sprinklers 18

NFPA 13D Developed subcommittee in 1973 Adopted in 1975 Purpose is to prevent flashover Improve the chances for escape or evacuation One- and two-family dwellings, manufactured homes and townhomes Life-safety system 19

Standalone Sprinkler System Dedicated piping for fire sprinkler system Backflow prevention usually required Usually installed with CPVC pipe 20

Passive Purge Sprinkler System Single toilet fed by sprinkler piping Backflow prevention may be required Installed with PEX or CPVC pipe 21

Multipurpose Sprinkler System Cold-water fixtures fed from sprinkler piping Backflow prevention not needed Usually installed with PEX pipe 22

Multipurpose Sprinkler System Less piping in the home Non-stagnant system Backflow prevention not needed Homeowner tests their system every day! 23

Attic Insulation For cold regions: R o = R i (T o -40)/(40-T i ) For hot regions: R o = R i (T o -120)/(120-T i ) Where T i = indoor, conditioned living space T o = outdoor, unconditioned attic space R i = R-value of insulation between tubing and conditioned living space below R o = R-value of insulation above tubing 24

Attic Insulation For cold regions: R o = R i (T o -40)/(40-T i ) For hot regions: R o = R i (T o -120)/(120-T i ) 25

Vapor Barriers Recessed Sprinklers All penetrations must be sealed No issues with semi-recessed sprinklers 26

Vapor Barriers Concealed Sprinklers Insulator will want to seal around cup of flat concealed sprinkler head Air must flow up through the sprinkler and out the top for correct operation Vapor Barrier 27

Vapor Barrier Solutions 28

AquaSAFE exposed listing Approved to be installed and left exposed in: Dimensional lumber Engineered wood (LVL, Glulam) Wood I-joist Open-web wood joists (wood floor trusses) 29

"New" Technology Flexible PEX tubing Multipurpose fire and plumbing combined Protecting exposed lightweight construction materials The forgotten system hopefully 30

Summary Learning Objectives The fire problem and solution Modern furnishings Open floor plans Modern (lightweight) construction Fire sprinkler myths Smoke alarms are enough to keep me safe When one goes off they all go off My house will get flooded if I burn toast Emerging technologies Multipurpose systems Flexible piping and system design Exposed applications 31

Thank you Eric Skare eric.skare@uponor.com 612-345-0073