Installation Instructions

Similar documents
Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions

GE Monogram. Automatic. Icemaker. Installation Instructions. Models ZDI15 ZDIS15. monogram.com

Installation Instructions

Installation Instructions If you have questions, call or visit our website at:

Installation Instructions If you have questions, call or visit our website at:

Installation Instructions

Installation Instructions

INSTALLATION INSTRUCTIONS

Installation Instructions

Installation Instructions If you have questions, call or visit our website at:

GE Monogram. Installation Instructions. Built-In Dishwashers. with Optional Trim Kit. Models ZBD5600 ZBD5700 ZBD5900

Installation Instructions

INSTALLATION INSTRUCTION In-Ground Color Changing

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

Installation, Operation and Maintenance Manual

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTION In-Ground

Installation Instructions If you have questions, call 800.GE.CARES or visit our website at:

Installation Instructions

Installation Instructions If you have questions, call 800-GE-CARES or visit our website at:

Installation Instructions

SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE

Installation Instructions

Design Guide with Installation Instructions

Installation Instructions If you have questions, call or visit our website at:

MICROWAVE OVEN UNDER-THE-CABINET INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION FOUR À MICRO-ONDES SOUS PLACARD MURAL

AGA TOTAL CONTROL. Model No. - TC3

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

2 PREPARE THE OPENING

Tetra MAX. LED Lighting System. BEFORE YOU BEGIN Read these instructions completely and carefully. Installation Guide

FES - Series Portable Electric Heaters

Installation Instructions

Installation Instructions

Installation Instructions 30 French Door Built-in Wall Ovens

Installation Instructions If you have questions, call or visit our website at:

Installation Instructions If you have questions, call or visit our website at:

GE Monogram. Installation. Instructions. Stainless Steel Built-In Refrigerators. Models ZISS36D SS, ZISS36N SS ZISS42D SS, ZISS42N SS

Stopper Station Series SS-2008 Push Button Pneumatic Timer Button

Installation Instructions If you have questions, call or visit our website at:

200i User s information manual

Installation Instructions

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Cooktop Chimney Ventilation Hoods

Stopper Station Series Push Button Models SS2xx2, SS2xx5, SS2xx9

Lumination TM Volumetric Retrofit Kit

Downdraft Ventilation

IMPORTANT: Read carefully before installation and retain for future reference. NOTE: Installation must be conducted by licensed electrician.

Installation Instructions

GE Monogram. Installation. Instructions. Component Cooktop System. Models ZEW145V ZGW124EN3 ZGW125EN3 ZEW155N ZEW166Y ZEW176Y

Escape Series Walk-in Bathtub Models 5128 and 5332 (soaker, water, air and microbubble jet models)

ChemScan mini Analyzer for Low Ammonia Monitoring Installation, Operation and Maintenance Manual

Questions? Call 800.GE.CARES ( ) or visit our Web site at: GEAppliances.com In Canada, call or visit

Lumination TM Controls Accessory LPL Series Controller Box

Installation Instructions

Installation Instructions

Integrated Ventilation System

Installation Instructions

Range Hoods. GEAppliances.com

PEDESTAL INSTALLATION INSTRUCTIONS INSTRUCTIONS D INSTALLATION DU PIÉDESTAL

Installation Instructions Use and Care Guide Instructions d installation Mode d emploi et d entretien

PH:

Microwave Oven. IMPORTANT SAFETY INSTRUCTION Never operate the oven when it is empty or without the glass turntable.

Smoke Control Listed LCM-OAVS VAV with HW Reheat, Two Venturi Air Valves (One Exhaust, One Supply) including BTU Compensation

SOLA SM II Light Engine Instruction Manual

Installation. Professional Built-in Hoods

System 350 S350A Temperature, S351A Humidity, and S352A Pressure Stage Modules

Installation Instructions

Installation Instructions

Installation Instructions Preference Wall Mount Range Hood

Owner s Manual. Stainless Steel Professional Island Range Hood. Models: ZV42 ZV54. Monogram.com

USER'S INFORMATION MANUAL SERIES 2 GAS - FIRED

Installation Instructions

PUREFIRE GAS BOILERS USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER

USER'S INFORMATION MANUAL SERIES 2 GAS - FIRED

INSTALLATION INSTRUCTIONS

Installation Instructions

USER S INFORMATION MANUAL PB HEAT, LLC 131 S. CHURCH ST BALLY, PA WARNING MISE EN GARDE TO BE COMPLETED BY THE INSTALLER.

RV30, RV36, RV46. 30, 36, 46 Wide, Raised Vent. Adjustable anchor legs. Front View

Installation Electric Dryers Instructions 01

USER'S INFORMATION MANUAL ES2 GAS - FIRED

MAXLITE RKT LED Retrofit Kit

Installation Instructions

INSTALLATION INSTRUCTIONS

Operating Instruction Manual

Range Hoods. GEAppliances.com

Installation Instructions

AB Parts. ControlNet Coax Tap. Installation Instructions. (Cat. Nos TPR, -TPS, -TPYR, -TPYS) What s in This Document

INSTALLATION INSTRUCTIONS

Easy installation in both new construction and retrofit RN80L RN110L READ AND SAVE THESE INSTRUCTIONS INSTALLATION GUIDE

Installation Instructions

Installation Instructions Built-In Dishwasher

PH:

HEARTH PRODUCTS KITS AND ACCESSORIES. KIT CONTENTS (See Figure 1) TOOLS NEEDED

Questions on Installation? Call: GECARES (US) or Visit our Web site at: (US) 4" DUCT CLAMPS (2) OR 4" SPRING CLAMPS (2)

e Bath Fan with Light User s Guide

Installation, Operation and Maintenance Manual

Transcription:

Installation Instructions 42" Island Vent Hood ZV1050 monogram.com 1

Safety Information BEFORE YOU BEGIN Read these instructions completely and carefully. Save these instructions for local inspector s use. Observe all governing codes and ordinances. Be sure to leave these instructions with the Consumer. Keep these instructions for future reference. Installation of this vent hood requires basic mechanical and electrical skills. covered under the Warranty. CAUTION: the risk of personal injury or damage to the product, we recommend at least three people install this hood. PRUDENCE : À cause du poids et de la taille de la hotte et pour réduire les risques de blessures ou de dommages de l équipement, nous recommandons que trois personnes installent cette hotte. WARNING: control device. Any such alteration from original factory wiring could result in damage to the unit and/or create an electrical safety hazard. AVERTISSEMENT : il ne faut pas utiliser cette hotte avec un régulateur ce type du branchement d usine peute endommager l appareil ou créer un risque de choc électrique. TO REDUCE THE RISK OF FIRE, USE ONLY METAL DUCTWORK. 2 WARNING: TO REDUCE THE RISK OF FIRE, ELECTRICAL SHOCK OR INJURY TO PERSONS, OBSERVE THE FOLLOWING: A. Use this unit only in the manner intended by the manufacturer. If you have any questions, contact the manufacturer. B. the service panel and lock service panel to prevent power from being switched on accidentally. If the service panel cannot be locked, fasten a tag or prominent warning label to the panel. AVERTISSEMENT : POUR RÉDUIRE LE RISQUE D INCENDIE, DE CHOC ÉLECTRIQUE OU DE BLESSURES, IL FAUT OBSERVER LES REGLES SUIVANTES : A. Utiliser cet appareil uniquement de la maniére prévue par le fabricant. En cas de question, consulter le fabricant. B. Avant toute intervention ou nettoyage, couper l alimentation électrique au disjoncteur et verrouiller le panneau du disjoncteur pour éviter la mise sous tension accidentelle. S il n est pas possible de verrouiller le panneau du disconcteur, attacher un placard ou une étiquette trés visible au panneau. accordance with all applicable codes and standards the heating equipment manufacturer s guideline and safety standards such as those published by the Society for Heating, Refrigeration and Air Conditioning When in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions. grounding must comply with applicable codes. In the absence of local codes, the vent should be installed in CAUTION: attics, crawl spaces or garages. PRUDENCE : Il faut prendre soin d incendie et pouvoir évacuer l air correctement. Il ne faut pas évacuer l air correctement. Il ne faut pas évacuer l air dans l espace entre les parois d un mur, un plafond ou un grenier, un espace sanitaire ou un garage.

Design Information CONTENTS Design Information......... Tools and Materials Required...5...5...6 Installation Instructions............... Step 6, Secure Wiring..................... PRODUCT DIMENSIONS mounted installations. It can be installed over any Mono *Height to Ceiling DUCT COVER ACCESSORIES ZX1059SFSS This kit includes a decorative duct cover and support ZX10510SFSS This kit includes a decorative duct cover and support 10" 31-1/2" 42" 32" for 9-ft. ceiling using ZX1059SFSS Accessory 44" for 10-ft. ceiling using ZX10510SFSS Accessory This vent hood is supplied with a decorative duct cover 3

Design Information DETERMINE INSTALLATION HEIGHT DUCT COVER ACCESSORIES Order the accessory at the same time as the vent hood Cover Accessory. Installation Heights *30" Recommended 36" Min. *9-ft. to 10-ft. ceilings may be 25-1/2" to 30" clearance. of the hood must be at least 25-1/2". The 30" recommended - sional Range or Rangetop, installation clearance must be at least 30". sure standard is applicable. DUCT COVER DIMENSIONS A B ZV1050 11-1/2" 12" ZX1059 19" 20" ZX10510 25" 26" Actual *Possible Hood 7'11" 29" Supplied 8'0" 30" Supplied 8'1" 30" Supplied 8'2" 25-1/2" to 30" ZX1059SFSS 8'3" 25-1/2" to 30" ZX1059SFSS 8'4" 25-1/2" to 30" ZX1059SFSS 8'5" 25-1/2" to 30" ZX1059SFSS 8'6" 25-1/2" to 30" ZX1059SFSS 8'7" 25-1/2" to 30" ZX1059SFSS 8'8" 25-1/2" to 30" ZX1059SFSS 8'9" 25-1/2" to 30" ZX1059SFSS 8'10" 25-1/2" to 30" ZX1059SFSS 8'11" 25-1/2" to 30" ZX1059SFSS 9'0" 25-1/2" to 30" ZX1059SFSS 9'1" 25-1/2" to 30" ZX10510SFSS 9'2" 25-1/2" to 30" ZX10510SFSS 9'3" 25-1/2" to 30" ZX10510SFSS 9'4" 25-1/2" to 30" ZX10510SFSS 9'5" 25-1/2" to 30" ZX10510SFSS 9'6" 25-1/2" to 30" ZX10510SFSS 9'7" 25-1/2" to 30" ZX10510SFSS 9'8" 25-1/2" to 30" ZX10510SFSS 9'9" 25-1/2" to 30" ZX10510SFSS 9'10" 25-1/2" to 30" ZX10510SFSS 9'11" 25-1/2" to 30" ZX10510SFSS 10'0" 25-1/2" to 30" ZX10510SFSS 4

TOOLS AND MATERIALS REQUIRED (not supplied) grounded branch circuit POWER SUPPLY IMPORTANT Please read carefully. WARNING: FOR PERSONAL SAFETY, THIS APPLIANCE MUST BE PROPERLY GROUNDED. AVERTISSEMENT : POUR DES RAISONS DE SÉCURITÉ, CET APPAREIL DOIT ÊTRE CORRECTEMENT MIS À LA TERRE. Remove house fuse or open circuit breaker before beginning installation. local codes and ordinances. Electrical supply connected to an individual, properly grounded branch requirements, call a licensed electrician before proceeding. installation location as possible. Allow an additional with local codes. Grounding instructions The grounding conductor must be connected to a ground metal, permanent wiring system, or an equip WARNING: The improper connection service representative if you are in doubt whether the appliance is properly grounded. AVERTISSEMENT : causer un choc électrique. En cas de doute, consulter 5

DUCT FITTINGS This Hood Must Use 8" Round Duct. It Can Transition to 3-1/4" x 12" Duct. permissible lengths for duct runs to outdoors. NOTE: sible equivalent lengths! Maximum duct length: 100 ft. for range hoods. Flexible ducting: the equivalent feet values in the table duct should be straight and smooth and NOT NOTE: Any home ventilation system, such as a ventilation hood, may interrupt the gas water heaters and other naturally vented systems. To minimize the chance of interruption of such naturally vented systems, follow the heating equipment manufacturer s guidelines and safety standards such as those published by When applicable, install in accordance with local building code requirements. Visit GEAppliances.com for available makeup air solutions. Total Duct Piece Dimensions Length* Used Length Round wall cap with damper 75 ft. Round length of duct pieces are based on actual tests conducted by GE performance with any ventilation hood. 6

Installation Instructions STEP 1 CONSTRUCT CEILING SUPPORT Plan the location the cooking appliance. See illustration. surface and bottom of hood. Front 15-3/4" Ceiling Hood Hood Ducting Centerline 31-1/2" Approx. 1-1/2" Beyond Cooking Surface Cooktop Countertop Side View Ceiling support structure ing structure. EXAMPLE A Symmetrically About Spacing 8" Duct Front of Hood ter of Cooktop Cooktop Outline 7

Installation Instructions STEP 1 CONSTRUCT CEILING SUPPORT (cont.) EXAMPLE B Spacing Symmetrically About 8" Duct Cooktop Center of Cooktop Outline Front of Hood EXAMPLE C Symmetrically About 8" Duct Spacing Front of Hood Center of Cooktop Cooktop Outline 8

Installation Instructions STEP 1 CONTINUED for the two supports. The cross-framing must be accurately aligned to ensure correct positioning of the hood. Check with a spirit level and adjust if necessary. IMPORTANT: The ceiling structure must be capable of supporting the weight of the hood (approximately 300 pounds) frame will be supported by the 2 x 4 min. cross-framing. permissible length for duct runs to the outdoors. ceiling joists or straight up through the roof. Finish the Ceiling the ceiling is level; use shims, if necessary. 9

Installation Instructions STEP 2 REMOVE THE PACKAGING The vent hood is packed separately from the decorative STEP 3 CHECK INSTALLATION HARDWARE AND ACCESSORIES hood and check contents. 11-1/4 TO CENTER LINE OF HOLES WIRE HOLE ACCESS 7-1/4 TO CENTER LINE OF HOLES WIRE HOLE ACCESS 2 Phillips-Head 4 Machine Screws Template 4 Hex-Head Lag Screws 4 Filters Stop Screw Mounting Screw Holes Support Frames with 8 Screws and 8 Washers 10

STEP 4 MOUNT TEMPLATE Installation Instructions in place. Be sure the template is oriented correctly, with the front of the hood. vide parallel alignment with the countertop below. access hole. Wire Access Holes STEP 5 INSTALL SUPPORT FRAME Hood Mounting Flange Lower Support 10" 30" Recommended 40" 76" Countertop Install upper support frame Install lower support frame desired height above the countertop. Tighten screws. IMPORTANT: Again, check to be sure the support is level in both directions. There is no way to level the hood after the hood is secured to the frame. 11

Installation Instructions STEP 6 SECURE WIRING below the support. STEP 7 SIZE AND INSTALL DUCTWORK Ceiling Support Frames Left Side View Tape House Wiring prevent damage during installation and service. frame (Dim. A). the frame to determine required duct length. NOTE: connection to the top of the hood. The bottom end should house ducting with sheet metal screws. 12

Installation Instructions STEP 8 INSTALL DECORATIVE DUCT COVERS Right Side Front Front Front on the support frame. This will make screw installation easier. in the top. and push to the ceiling. decorative screws. package. Set aside. duct and push to the top. a stop screw and prevent the lower decorative duct cover from sliding down. CAUTION: The stop screw must be installed. to the duct cover. PRUDENCE : capot antipoussière. STEP 9 INSTALL HOOD NOTE: AT LEAST THREE PEOPLE ARE REQUIRED TO COMPLETE THIS INSTALLATION! hood mounting holes to the support frame holes and, at the same time, the hood duct connector into the duct. hood connector. NOTE: Bottom Duct Cover Stop Screw Install 4 Lock Washers and 4 Machine Bolts Apply Duct Tape to Seal Duct Connection 13

Installation Instructions STEP 10 CONNECT ELECTRICAL STEP 11 SLIDE DUCT COVER DOWN WARNING: with a ground wire, a ground must be provided by the installer. When house wiring is aluminum, be sure to use copper connectors. AVERTISSEMENT : Si le câblage de de la maison sont en aluminium, il prendre soin d utiliser cover. bare ground lead. connector. wires are not pinched. all wire harnesses out of the path of the duct cover seating. 14

Installation Instructions STEP 12 INSTALL FILTERS, FINALIZE INSTALLATION Filter Slots lower slots at the rear of the see if the red light is glowing in the display. If the red check that house wires have been connected securely and that no wires have been damaged during installation. Check the breaker or house fuse is turned on. 15

Note: While performing installations described in this For Monogram local service in your area, call 1.800.444.1845. Note: General Electric. Therefore, materials, appearance and Printed in Italy 16