Belt Conveyor Safety Monitoring Devices

Similar documents
Ramsey Motion Monitoring Systems

Ramsey Series Motion Monitoring Systems Accurate Sensing of Speed Conditions on Rotating Shafts and Machinery

vibration switch

SAPCON SMART-SSI. Continuous Speed Indicator. Users Manual. . Introduction. . General Description. . Principle of Operation. .

Thermo Scientific Ramsey TM Series Sensing Speed Conditions on Rotating Shafts and Machinery

T500 Elite - Hotbus Plant Wide Monitoring System for Bucket Elevators & Conveyors

DSD-3 DIFFERENTIAL SPEED DETECTOR

MASTER JOCKEY PUMP CONTROLLER. Model JPCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

MASTER PRESSRE MAINTANENCE CONTROLLER. Models PMCE INSTRUCTION MANUAL. C 2018 Master Control Systems, Inc

Monitoring Equipment

Watchdog Elite Watchdog Elite BRAIME Product Information Bucket Elevator & Conveyor Hazard Monitor

MULTI-STAGE CHILLER CONTROL

Process Alarm Module RTA 421

Motion Sensors. Milltronics MFA 4p. Operating Instructions

Is your process protected?

Arc Fault Protection System D1000

D1000 Arc-fault Protection System

Indirect gas-fired air heater

UDC100 Universal Digital Controller Specifications

GG-EM ENTRANCE MONITOR. Installation and Operation Manual

ANEMOMETER 4403-RF-BAT

Sitron s CF Line of Flow Switch Monitors

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

SECTION ROTARY-SCREW WATER CHILLERS

OPERATION MANUAL Part No. s - WDC4V4C, WDC4V46C Hardware Version R4 - Software Version 4.7.X

Gate Operator. Modfications

VIBRATION TRANSMITTER MODEL 140T INSTALLATION The mounting orientation can be in any position. This position should be in an area for the best vibrati

AS570 Chill-Out Combination Sensor Installation and Operating Instructions

The Murphy EVS Electronic Vibration Switch. Installation and Operations Manual Section 20

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

tcm100, tcm101 Series Temperature Control Modules and PTS100, PTS100/3 Pipe Temperature Sensors Operations Manual

Process Protection. MFA 4P Motion Failure Alarm

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

Instruction Manual December 2001 ENACOCU02

ISIS SAFETY SYSTEM Installation guide

Instructions. Easy-wire terminal strip Microprocessor-operated. Easy remote sense. Self-checking program. Diagnostic/status LED s

Installation Guide for AL600ULM. Multi-Output Access Control Power Supply Charger. Rev

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Série Détecteur de niveau par admitance RF. SB RF-Admittance Level Switch

Instruction Manual August sitrans CU 02

INTRODUCTION / TABLE OF CONTENTS

Date SECTION MEASUREMENT AND CONTROL INSTRUMENTATION Project Name Page 1

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

Oxygen (O2) Single-Point Gas Detection System

Safety Control Modules for Emergency Stop Circuits FF-SRS5988 FF-SRS5935 FF-SRS5925 FF-SRS5934 FF-SRS5924 TYPICAL APPLICATIONS APPROVALS DIMENSIONS

Nitrogen Dioxide (NO2) Single-Point Gas Detection System

Operations Manual. Motion Detector Module Model ZS10

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power to dryer before servicing, unless testing requires power.


Serie Rugghölzli 2 CH Busslingen. Tel. +41 (0) Fax +41 (0)

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

rev3 INSTALLATION & OPERATION MANUAL OIL CIRCULATING HEATING SYSTEM MODEL OSM

Single Point Freeze Protection Heat Trace Control TRACON MODEL FPT 130 Installation and Operation Manual

Capital Controls SERIES 70CV3000 CHLOROMATIC VALVE

Electro-Sentry. Users Manual

ESSEX ENGINEERING CORPORATION

Lubrication cycle IP Enclosure Rating. 110 VAC, 220/230 VAC (50/60 Hz) Alarm Fault Relay Contacts. IP-55 (Liquid tight connector)

Sensepoint XCL Fixed Gas Detector

pre-wired E3FA-TP11-F2 2M E3FB-TP11-F2 2M

HOW LIMIT AND BASIC SWITCHES CAN STOP MACHINES FROM GOING BOOM. A Honeywell White Paper

Speed and Frequency Seite 1 von 7

C6097A,B Pressure Switches

SILO PROTECTION SYSTEMS

Centro-Matic Automated Lubrication Systems System Controls

How Limit Switches Can Stop Machines from Going Boom

RTA421. Technical Information. Limit alarm switch Alarm switch and power supply for monitoring current or voltage signals

User s Manual. TIGER S EYE E-Series Mark V Jockey. TIGERFLOW Systems, Inc Mint Way Dallas, Texas

DIESEL Engine Fire Pump Controllers Features

EOTec 2000 ControlNet Fiber Optic SHR/DSHR Communications Modules* With Support for Single and Dual Channel Self-Healing Rings

Two-Channel Gas Controller

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Two-Position Electric Duplex Room Thermostats

Instructions for the heat exchanger control system SILVER C RX, RECOnomic, sizes 100/120, RECOsorptic, sizes

INSTALLATION INSTRUCTIONS

DRI-AIR INDUSTRIES, INC. AHM & HPHM 2-4 HOPPER MOUNT DRYERS OPERATING MANUAL

Safety Photo Beam UL MONITORED DEVICE

3800 North Mill Road Vineland, NJ USA Tel: Fax: Web: Rev. A

Dräger Polytron 8310 Stationary gas detector (DSIR)

MANUAL RESET ALARM RELEASE

MODEL FPT-130 SINGLE POINT FREEZE PROTECTION HEAT TRACE CONTROL

Product Range Overview

F Operating Manual. ESS0460-H119 PV Module Solar Soaking Chamber

Hoffman Controls 759-ECM. Installation & Operating Instructions. Introduction. Installation. Pre-Installation Information/ Instruction

Conventional Releasing Control Panel

DTA. Motor thermistor relay. Benefits. Description

Eclipse Self-Check UV Scanner

Installation and Operating Instructions

INSTALLATION, OPERATING & MAINTENANCE INSTRUCTIONS FOR 870 SERIES INDUSTRIAL CONTROL PANELS

CAPITAL CONTROLS SERIES WP70CV3 GAS FEEDERS

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

0-2 m/s Lo Alarm 0-6 m/s Hi Alarm Signal Stregth EASZ-12 Doppler Flow Switch Measuring Flow Worldwide

INSTALLATION INSTRUCTIONS

Introduction to Flow Switch

FACTORY AUTOMATION. Instruction Manual NBB20-L2-E2B-C-V1 NBN40-L2-E2B-C-V1 Inductive Sensor

T7984 A,B,C Electronic Modulating Control Thermostats

! WARNING To avoid risk of electrical shock, personal injury or death; disconnect power before servicing, unless testing requires power.

Pioneer-R16 Gas Monitor Operator s Manual

Installation Guide for AL400ULM. Multi-Output Access Control Power Supply Charger

Premier Hazard STC Instructions

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Transcription:

ISO-00:000 certified Belt Conveyor Safety Monitoring Devices More than just another level measurement company. Aplus Finetek Sensor, Inc.

SRT CONVEYOR BELT MISALIGNMENT SWITCH PRODUCT INTRODUCTION The SRT is designed to be used for monitoring hazardous conditions of conveyor belt misalignment during conveyor operation. When the SRT detects a misalignment condition two alarm outputs are triggered depending upon the degree of misalignment. The first output is used as an alarm notification that a serious misalignment condition exists, while the second output is triggered for conveyor shutdown due to the detection of a serious hazard misalignment condition. The SRT is used to protect belt conveyors from damage and to assist in ensuring personnel safety OPERATING PRINCIPLE SRT conveyor belt misalignment switches are generally mounted on both sides of the conveyor belt at the belt edge. A small clearance between the SRT contact roller and the normal swaying (about 0. /0mm) of the belt should be allowed for. When belt swaying exceeds the normal amount the belt edge will begin pushing against the contact roller of the SRT. Continuation of belt swaying or misalignment will continue to push the contact roller, which will drive the switch and operate the output contacts. The first output contact can be used to indicate an alarm due to a deviation of the conveyor belt. The second switch output can be used to protect against an extreme misalignment condition or belt runoff by shutting down operation of the conveyor. The SRT misalignment switch will reset automatically when the belt resumes its normal position and operation. The switch output activation points are adjustable from between 0⁰ to ⁰ by a change of the actuating cams. Refer to illustration. DIMENSION Unit:inch(mm) FEATURES Ÿ Easy to install, sensitive operation Ÿ Roller arm can move up to ⁰ in both directions Ÿ Dust-tight IP weatherproof die cast aluminum powder coated enclosure Ÿ Standard actuating angle 0⁰ for alarm and ⁰ for emergency conveyor shutdown Ÿ Reduces process downtime, product loss, saves replacing conveyor belt and enhances safety APPLICATIONS Ÿ Conventional belt conveyors Ÿ Underground, cable supported belt conveyors Ÿ Stacker/Reclaimer conveyors Ÿ Ship loading/unloading systems Ÿ Tripper and shuttle conveyors Ÿ Crane/shovel boom position limit detector Ÿ Apron feeders & conveyors SPECIFICATIONS Switch output Reset method Ambient temp. Enclosure protection Enclosure material Weight Two () SPDT, 0A @ /0VAC, /A @ VDC Automatic -⁰F~0⁰F (-0⁰C~0⁰C) IP Diecast Aluminum Powder Coated.lb (.kg)." ()." () f." (f0) Touch pulley 00SS Cable size f0. "~ 0. "( f~ )." (0) Case Cover Cover bolts 0SS 0."±0." (±) 0." (0) 0." () 0." (.)."." (0) ()." ()." (0)." ()." (0) 0." () 0." ().0" ()." ()." (0).0" ()." ()." (0) -f0." (-f0)."±0." (±0)

SRS BELT CONVEYOR SAFETY CABLE STOP SWITCH PRODUCT INTRODUCTION The SRS is a belt conveyor safety cable stop switch designed to provide a switching system to disconnect power to a conveyor system or other process equipment in the case of an emergency condition. A coated steel cable can be used to activate the stop switch from long distances. The SRS cable stop switches can be placed and mounted along large distances of belt conveyors. OPERATING PRINCIPLE The SRS safety cable stop switch is actuated by pulling on the steel cable which is mounted along the conveyor and attached to the safety stop switch. When you pull on the cable at any point it will trip the stop switch and automatically lock the switch in the off position de-energizing the conveyor starter contactor. Each SRS is bidirectional in its operation and has two cable attachment points, one from each direction terminated with a spring at the anchor points. Refer to product Manual for more operational information. The spring will operate the SRS stop switch should the cable break. After being tripped, the mechanical latch of the switch can only be reset at the switch itself by the reset lever. DIMENSION Unit:inch(mm) FEATURES Ÿ Universal design for bi-directional operation Ÿ Compact design for tight spaces Ÿ IP rugged Diecast aluminum enclosure, powder coated Ÿ Manual reset lever Ÿ Easily located at either end or intermediate point along belt conveyor Ÿ Cable pull down 0 degrees to shutdown system Ÿ Highly visible SPECIFICATIONS Switch output Lever force Reset method Ambient temp. Enclosure protection Enclosure material Weight APPLICATIONS Two () SPDT, 0A @ /0VAC, /A @ VDC 0.lbf~.lbf (.N~.N) Automatic -⁰F~0⁰F (-0⁰C~0⁰C) IP Diecast Aluminum Powder Coated.lb (.kg) Ÿ Conventional belt conveyors Ÿ Shuttle Conveyors Ÿ Bucket Elevators Ÿ Packaging Lines Ÿ Stockpile/Reclaim systems, Cranes, Shovels, Ÿ Draglines Ÿ Ship Loading / Unloading System Ÿ Horizontal Feed Systems." ()." (00) Shart 0SS." ()." (00) Case 0." ()." () Cover 0."." () (0) 0." ()." ()." (0) 0." (0) 0." () 0." () Cover bolts 0SS.0" () 0." ()." ()." ()." (0)." (0) 0." () - f0. " (f-0 Mtg.holes).0" () Operation-indicating plate Color:MUNSELL R/ 00SS." (0) Cable size f0. "~ 0. "( f~ )PA." ()." ().0" ()." (0) Shackles." (0)." ()

ED000 SPEED MONITOR PRODUCT INTRODUCTION The ED000 is a totally new instrument used for monitoring the speed of rotating devices such as rotating conveyor shafts, motor shafts, etc. It measures RPM from ~ and indicates the speed on its internal -segment LED display. A relay contact is provided that can be used for alarm or control purposes. The ED000 primary output is an analog ~0mA signal of the measured speed that can be tied into a PLC, control system or local indicator (ask Aplus Finetek Sensor about our own brand of digital and bargraph display indicators). OPERATING PRINCIPLE The ED000 uses the principle of photo detection and microprocessor electronic technologies to accurately calculate rotational speed over a range of ~rpm. Alarm and continuous analog outputs are provided for alarm/control and speed output. The alarm setpoint can be directly set by a series of three () ten (0) position switches on the top PCB inside the ED000 enclosure. SPECIFICATIONS Measuring range Display Alarm setpoint Alarm conditions Startup delay Alarm output Alarm delay Speed analog output Power supply Power consumption Operating temp. Enclosure material Enclosure protection Conduit entrance 0~rpm -segment LED, 0~ ~, adjusted by use of three () rotary switches Underspeed, Stopped, Power Failure Selectable 0s or s SPDT Relay, A @0VAC Selectable 0s, s, s, s, s, s, s, s, s, s ~0mA (range selectable 00/00/00/000rpm) Universal -VAC, 0/0Hz VA -⁰F~⁰F (-0⁰C~0⁰C) Diecast aluminum, powder coated IP Two () ½ NPT FEATURES Ÿ Maximum measuring range ~rpm Ÿ -segment LED display Ÿ Alarm monitoring: low or Underspeed, stop, reverse, overload conditions, power outage Ÿ Startup delay: allows equipment motor to run up to speed gradually Ÿ Alarm delay: avoid faulty alarm indication due to temporary slowdown or a load change Ÿ Selectable for CW or CCW rotation Ÿ Light pulses will not be affected by environmental conditions Ÿ Panel meter or bargraph display indicator available Ÿ -0mA output has selectable speed range: 00rpm, 00rpm, 00rpm or 000rpm Special Function (built in function) ~0mA output, proportional to selectable speed range like 00rpm, 00rpm, 00rpm and,000rpm. APPLICATIONS Ÿ Low speed detection Ÿ Conveyor overload protection Ÿ Bucket elevators Ÿ Belt conveyors DIMENSIONS Unit:inch(mm).0" (0)." () /"NPT 0." ()." (0) 0." () Minimum space 0." (.)." (0)." (0) 0." (.)." ()." ()." (0)." (00) f0. " (f) Install counterclockwise Belt /" or M0 Screw hole Metal cable tie Metal cable tie Inertial roller EDA-00 /" or M0 Copper connector screw Install clockwise EDA-00 Flexible rubber tube (Unit:mm) Speed monitor

OPERATOR INTERFACE Setpoint rotary switches Bi-color LED (Green Power/Normal; Red Power/Alarm) Startup Delay rotary selector switch -0mA output range selector switch -segment LED 0 SW SW SW SW 0 SW 0 0 SW SW DESCRIPTION OF OPERATION. Setpoint rotary switches (SW, SW and SW) The function of these three rotary switches is for setting the alarm setpoint. There are three () rotary switches; SW = x00, SW = x0, SW = x. If the desired setpoint is rpm, then rotary SW to position, SW to position and SW to position. The alarm will occur when the detected speed is below this setpoint.. Alarm/Power Indicator (Red/Green) a. This is a bi-color LED, only one color is illuminated at a time. Upon power up of the ED000 and subsequent to the startup delay time, the Green will illuminate in a flashing manner for seconds and then solid green if the detected speed condition is Normal. b. Under Normal operating conditions with power applied, when no alarm is detected, the Green is illuminated. When an alarm condition is detected and the alarm delay has expired, with power applied, the Green color will extinguish and the Red will be illuminated to visually indicate that an Alarm condition exists.. Startup delay rotary switch (SW) The startup delay allows the equipment motor speed to come up to normal rpm slowly without an immediate alarm condition being detected by the ED000. The 0~ positions on the SW rotary selector switch are startup delay setting as follows: Switch setting 0 APPLICATION EXAMPLE AC ~V Power Supply Relay Contact (To Alarm Lamp or Motor Stop Switch) Delay time S S S S S S S S S 0 S. -0mA output range selector switch This switch converts the detected and measured speed into a proportional current output with four possible range settings for the -0mA output. The four possible ranges are 00rpm, 00rpm, 00rpm and 000rpm. For example, if the range setting switch is set for 00rpm then input speed of 0-00rpm will be converted to -0mA output. If the detected speed is 0rpm, then the output current signal will be ma. -0mA Output Analog Indicator Digital Panel Meter SP % rpm Below is the diagram of control circuit. Motor speed is monitored by ED000 (SM). Motor starts to speed up after activation. ED000(SM) starts to monitor after delay time being activated. It monitors if motor is under low speed. When speed is too low, alarm will be issued to stop motor running. R S T MC OLR M Bargraph Panel Meter STOP START 0V MC AC 0V COM NO ED000 (Sm) ED000 (SM)

Global Network Germany China Taiwan U.S. U.S. Singapore Asia North Amerca Europe Taiwan FINETEK CO., LTD. TEL: --- FAX: --- EMAIL: info@fine-tek.com California, U.S. APLUS FINETEK SENSOR INC. TEL: 0 FAX: 0 EMAIL: info@aplusfine.com Germany TEL: +-(0)-0-0 FAX: +-(0)-0-0 EMAIL: info@fine-tek.de China FINE AUTOMATION CO., LTD. TEL:--0-0 FAX: --0- EMAIL: info.sh@fine-tek.com Illinois, U.S. APLUS FINETEK SENSOR INC. TEL: - FAX: EMAIL: info@aplusfine.com Singapore FINETEK PTE LTD. TEL:--0 FAX: -- EMAIL: info.sg@fine-tek.com Represented by: Aplus Finetek Sensor, Inc. 0-SRST-B0-AM, /0/0