Model SPA-516 HOT TUB OPERATING INSTRUCTION

Similar documents
Model SPA-8138 HOT TUB OPERATING INSTRUCTION

Model SPA-308 HOT TUB OPERATING INSTRUCTION

PROGRAMMING INSTRUCTIONS

USER MANUAL OF KL8300 SYSTEM

HOT TUB. Model SPA-313. Serial No: POPERATING INSTRUCTION

User manual Whirlpool

beyond 260VAC, then LED shows. In these two kinds of situation, the system will not go into normal operation.

Massage Bathtub. Instructions of Installation and Use. Preparations MT-RT1804. Cleaning & Maintaining

SG User Manual

15,000 BTU Portable Air Conditioner

Installation Instruction of AM168 TS-series Control panel

Installation Instruction of AM124ETL-L TS-series Control panel

Spa Touch Control Panel with BP2100, BP6013 spa controllers. (Spa Owner s Manual insert)

Spa Touch Control Panel with 2000, 2100 controllers. (Spa Owner s Manual insert)

Preparations MT-RT1806. Cleaning & Maintenance. Precautions

AVANT DGi. Thermal Electric Radiator. Operating and Installation Instructions. (Read these instructions carefully and retain for future reference)

Contents. Specifications. Description SV HP 55 SV HP 90. Specifications Warnings Introduction Overview... 4

DIGIHEAT IN LINE HEATERS

ML550, 551, 554 Panel Operation

I. U881 Series Structure...1 II. Security Advice...2 III. Technical Parameter...3 IV. Install U881 Sauna Room V. Electricity Supply And Water

WINE COOLER INSTRUCTION MANUAL

INDUCTION COOKER MODEL: EIC-G1810(BK) Owner s Manual. Please read this manual carefully before operating your set. Retain it for future reference.

Wired Controller XK60

99 F PREHEAT. C d. Topside Controls for Spas with Three Pumps

Installation and Operating Manual

INSTALLATION AND USER MANUAL

HT-2 / 9600 Series Control Contents

Instruction manual. Aluminium radiator with ceramic heart. Smart Electric Heaters

Portable Air-conditioner

Touch Screen Thermostat. MTSC/SUPER, MTSC24/SUPER Series. MTS/SUPER, MTS24/SUPER Series. Owner s manual and technician settings

ETNC24-FC-BAC-PIR-01 Owner s manual & Technician Settings

System. For a better understanding of this product, please read this user manual thoroughly before using it.

TC-NHP01-A, TC-NAC01-A Comfort Series Non- Programmable Thermostat. Owner s Manual

Warning: 230V / 1ph / 50Hz V / 3ph / 50Hz. Remarks: Make sure that you have enough power. (See page 15 Cable table)

Briza Line. Digital Display Unit (Room Thermostat) Model BLC 13-RS Wall Mounting Cat Model BLC 33-RS Semi Flush Mounting Cat.

RGR150 USER S MANUAL. Wireless Rain Gauge with Thermometer and Clock

Installation and Operation Manual

OPERATOR S MODEL HHC-901 HHC-904 HEATED HOLDING CABINET REGISTER WARRANTY ONLINE AT

INSTALLATION AND USER MANUAL

Touch Screen Thermostat. MTSC/SUPER/CO2, MTSC24/SUPER/CO2 Series. MTS/SUPER/CO2, MTS24/SUPER/CO2 Series. Owner s manual and technician settings

ATA11U03. Non-Programmable Heat Pump Thermostat. Installation Manual. 97B0082N06 Revised: 16 September, 2013 FOR INSTALLER AND OWNER ONLY

Europa Shower Cabinet

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Reverse Cycle Split System Air Conditioner

PORTAPAC / DELTA HOT. Installation and Operation Manual. ! WARNING

Wine Cooler. Instruction Manual PWC-24ZWX

Hand Dryer Installation & User Manual

No advanced advice will be submit before we change our design and size. The pictures may be a little different from the real products.

SERVICE MANUAL UNI SPLIT SERIES. ASC-xxBI, ASD-xxBI, ASF-xxBI, ASGE-xxBI, ASGE-xxBI-3

/ De Longhi Appliances via Seitz, Treviso Italia

No advanced advice will be submit before we change our design and size. The pictures may be a little different from the real products.

Owner s Manual 33-bottle Under-Counter Wine Cooler Model: WC-3302US

Table of Contents. SLIMLINE Series MODEL: SLIMLINE

FPC-02 Series. Installation and Operating manual

CR9934 ROBERTS. PLL Dual Alarm Clock Radio. Sound for Generations. Please read this manual before use

C&H NORDIC Commercial 4 SERVICE MANUAL

Medical Refrigerator

HEALTH POT MODEL: EHP-E1881G(WH) EHP-E1882G(OR) Owner s Manual. Please read this manual carefully before operating your set.

Installation and user s manual Read carefully and keep it for later reference

Inverter Swimming Pool Heat Pump

FAN COILS wall mounted

Operator: Save these instructions for future use!

155mm. 820mm. 540mm E D. 940mm. 600mm

The Vitro-i. Radiant / Convector Combination Heater. Instructions for Operation and Installation

spatouch Menued Control Panels

OWNER S MANUAL HIGH WALL INVERTER. (English) (BSHVD1S SERIES)

Oceanic Sauna Heater Manual

GSM Alarm System. User s Manual. Profile. MOBILE CALL GSM Alarm System

Xcelsior Spa Pool System

Table of Contents. Product Image Table of Contents What is a Programmable Room Thermostat? Installation Procedure

I K. V.lla ADVANCED SYSTEM - M0S Edizione 1H10

LEVENS STEAM SHOWER ENCLOSURE

PORTABLE AIR CONDITIONER

Overview JUG CLAMPING LEVER JUG HUSK DRAWER SAFETY MICRO SWITCH TOUCHPAD ON/OFF SWITCH LED DISPLAY TEMPERATURE CONTROL (IF FITTED) FUSE HOLDER

OPERATION & INSTRUCTION MANUAL. itouch GS08M(9kW & 18kW)

Part 8 PROBLEMS AND SOLUTIONS

OWNER S MANUAL DUCTED INVERTER. (English) (SDHV SERIES)

ARLEC. User Instructions

Portable Air-conditioner Use and Care Manual

EL/GL Series - Mach 3 ML550 User Guide

GeyserWise MAX. Instruction manual. All in one hot water management

VADA - Rain2Main Automatic Rainwater Controller

Refrigerated air dryers

OWNER S MANUAL HIGH WALL INVERTER. (English) (MSHVD1S SERIES)

User Instructions for Remote Controlled 2kW Rotisserie Effect Fan Heater Model 1276

Model: Slimline-N. 1 Slimline Series

OWNER S MANUAL DLFCAB / DLFCHB / DLFDAB / DLFDHB High Wall Ductless System Sizes 09 36

USER MANUAL

: PRT / PRT PRT / PRT-N1

Telephone Helpline: (Australia) Blast Chiller / Freezer. Instruction Manual. Model DN492-A DN494-A

Mobile Air Conditioner Use and Care Manual. Part Number: 048-GM-48265

TC-PHP01-A, TC-PAC01-A Comfort Series Programmable Thermostat. Owner s Manual

INSTALLATION MANUAL & OPERATING INSTRUCTIONS

MILK FROTHER INSTRUCTIONS FOR USE

Bubble Massage Bath (Include Electronic Drain)

Inspect bath carefully and report any damage or faults before installation. No claims can be entered in to after installation.

CELSI ELECTRIFLAME XD

GSM Smart Home Alarm Apparatus. [99+4 defense zones] Instruction for Use

PDA20DX Air Purifying Dehumdifier Manual

Harmo Powerpack Horizontal Units Installation & instruction manual

Transcription:

Model SPA-516 HOT TUB OPERATING INSTRUCTION 1

1. I Illustration to buttons Fig.1:Control Panel MIN Frequency up- searching / Minute On-off/Setting confirm HOUR Frequency down- searching/ Hour Radio or DVD/TV Switch/ On-off + Volume up/ Set switch Blower On-off/ or Switch - Volume down/ Open Spa Light On-off MEM Radio channel Memory/ Lock Surfing pump 1 On-off SET Radio channel read / Close Surfing pump2 On-off Lasting Circulation Cleaning On-off Surfing pump3 +circulation pump On-off/Set Circulation Cleaning Time Heating On-off / Set Pre-heating Set Temperature Note:.The functions listed with blue letters only works on the condition of on-off II Function Summary 1 Max. with 6 KW heating system, set pre-heating, set and display temperature 2 With 3 surfing pumps,1 circulation pump, 1 view pump, and 1 blower. 3 Ozone, Spa lights. 4 CD audio-input / Display of radio frequency and preserve 10 channels 5 Volume display and 87 frequency adjustment 6 Circulation cleaning and time set of circulation cleaning 2

7 24 hours display and time set 8 Memory preserve once power off 9 Fahrenheit & Celsius degree switch 10 Antifreezing functions 11 Keys with backlight 12 Lock setting 13 Three-phase or single-phase, available of 110-120VAC or 220-240VAC 14 Choice with CD function, offering a AC supply for circumscribing DVD or TV 15 Choice with power control 16 Choice with galvanoscope device III Operation Fig.3:Temperature Normal Display Fig.4:Senor on/short circuit display 1 When you first start the spa, the backlight will be dimmed and the LCD will show the current time and temperature. If there is a problem with the circuit board the controller will display the code E1. When the radio frequency is displayed as --- it indicates that the spa is in power off model, and pre-heating and circulation cleaning function is off. 2 Lock memory Mode(optional function): MEM The memory lock will start work by pressing key in the status of power off when the spa has not been adjusted for a period of 30 minutes. When the memory locked key is pressed TWICE MEM the spa will become unlocked and the word LOCKED will disappear. 3 Adjusting Time: In the status Power off and the pre-heating and circulation cleaning are not starting. Pressing MIN or HOUR adjust time. The Minute and Hour display flash at this time. It will add 1 hour when pressing HOUR each time and the hours can be adjusted continually when pressing the HOUR without stopping. The hour adjustment range is 0-23. In the status of time setting It will add 1 minute when pressing MIN each time and the minutes could be added continually when pressing the MIN without stopping. The minute adjustment range is 0~59 The system will quit the time-setting status automatically after 6 seconds without pressing any buttons 3

4 Set pre- circulation-cleaning: In the pre-set mode circulation will be automatic once per day. The display will show clearly whether circulation is in action or not. See following Fig 5-6: AM AM Fig.5:Circulation-cleaning off Fig.6:Circulation-cleaning on When setting the Circulation-cleaning the display must be in the Power off status and the LCD display --- 1) Press to enter Circulation-cleaning setting mode and the LCD shows and flashes,and then the circulation works on. Press again to off the circulation cleaning, and the will disappear. 2) Press (minutes)and (hours) to adjust the time. It will add 1 minute when pressing MIN each time and the minutes could be added continually. The adjustment range is 0~59. It will add 1 hour when pressing HOUR each time and the hours could be added continually. The adjustment range is 0-23. After setting the circulation cleaning pre-set timing, go to next step. 4

1) circulation 2) Set start of circulation 3) Set lasting time for circulation 4) Finished 3) Press to set the circulation times; it will show the minimum(5 minutes) on the LCD and this time will not flash. It will add 5 minutes by pressing each time. It will add 1 hour by pressing each time The maximum working time is 19hours and 55 minutes. When you have completed this procedure continue to the next setting. 4) If all settings have been correctly, set Press for confirmation, the system will quit this mode automatically(press key to clear settings and exit). ***Notice*** 1 All the setting of Circulation-cleaning must be set on Power OFF status 2 Circulation PUMP and OZONE are not working while setting the circulation cleaning. 5 Set preheating (if required): Only one pre-heating setting is allowed each day if required.the LCD can show clearly in the following figures whether pre-heating settings are set or not See following Fig.7-8: 5

ON OFF Fig.7:Pre-heat On 图 8:Pre-heat Off Pre-heating is set when the spa is in the Power off status and the LCD display shows --- 1) Set preheating 2) Time setting for Preheating 3) Continual time of preheating 4) Preset temperature 5) Finished 6

1) Press and enter Pre-heating setting mode, and the LCD flashes of ON, the PREHEAT icon will flash, and then the circulation works on. Press OFF without flashing. again to turn off pre-heating. The LCD will show 2) Press (minutes)and (hours) to adjust the time. It will add 1 minute when pressing MIN each time and the minutes could be added continually. The adjustment range is 0~59. It will add 1 hour when pressing HOUR each time and the hours could be added continually. The adjustment range is 0-23. After setting the heating pre-set timing, proceed to the next step. 3) Press to set the circulation times; it will show the minimum(10 minutes) on the LCD and this time will not flash. It will add 10 minutes by pressing each time. It will add 1 hour by pressing each time The maximum working time is 19hours and 50 minutes. When you have completed this procedure continue to the next setting. VOL+ 4) Press SET again It will show SET on the LCD panel. Press button to change the setting temperature. The range of temperature setting is: 15~45 5) When everything is set correctly, press the to confirm, the system will quit the pre-heating setting mode. ***Notice*** 1 All setting of preheating must be in Power OFF mode, just turn on the spa,the LCD will display --- 2 Please note that it shows "on" or "off" on the LCD. "on" means preheating is turned on mode. when the time of pre-heating is as same as current time, the heater will start working. "off" means the heater won t start to work an any time. 3 Circulation PUMP and HEATER without working while setting preheating. 6 Operation of preheating: When the preheating time is as same as the current time, the LCD screen shows on and the tub is also filled with water. The heater will start to work. The heater, circulation pump and time counting work at simultaneity. The countdown time will be shown on the LCD screen, till the preset time is finished. During the preheating, The preheating will be turned off automatically once the preset time is finished. Or Pressing the or ON/OFF key can stop preheating. 7

***Notice*** i. When setting temperature is lower than or equal with water temperature, Even the Preheating is on, but the circulation PUMP and HEATER are not working ii. When the HEATER is I type frame,the power of circulation PUMP must reach 750W Otherwise the heater won t work due to not enough water pressure to drive pressure switch. iii. Conditions meet the above 2,and the HEATER is still not working,please short the line of water pressure switch 7 Circulation-cleaning: When the current time is as same as the presetting time, the preset is and the tub is filled with water, the circulation cleaning will start, the circulation pump works at the same.. The LCD shows the countdown time. All the surfing pumps and blower will work for 30 seconds at every 30 minutes. The Ozone works at every 15 minutes. During the preheating, the Circulation cleaning will be turned off automatically once the preset time is finished. or Pressing the key can stop directly. 8 Operation to Power ON/ OFF Pressing the key from power-off status to enter the power-on status. To pressing the in the status of power-on to enter the power-off status. The LCD screen shows the on or off. See following Fig.9-10 AM OFF AM OFF Fig.9:OFF 9 Temperature setting: Fig.10:ON Under the status of Power-on can setting temperature. It will add 1 centigrade by press the temperature will be added continually till reach 45 centigrade(113 Fahrenheit ) by press each time, without stop. Press again,and the temperature is show 15 (59 Fahrenheit) The range of adjustment is: 15~45 (59~113 Fahrenheit) 10 Operation Radio & CD: AM Fig.11:Radio frequency is 105.2 MHZ,Save the present frequency to channel 3 (Save channel) PUMP3 8

or Exchange the frequency form channel 3 to the present (Searching channel) I is the ON/OFF key for radio and CD and it is only available in the status of power on. The first pressing is turning on the radio,the second pressing will turn off the radio and turn on the CD at the same time,and the third pressing,will turn off the radio and CD simultaneous Ⅱ LCD will show present frequency and volume of the radio after turning on the radio HOUR Ⅲ In the working of radio, the present radio frequency can be changed by pressing MIN and Ⅳ Pressing the key SET will take out the memorized radio frequency,pressing the key SET continually will take out the memorized radio frequency from channels will be saved at present channel by pressing this key continually If none of the channel, LCD will display --- MEM Ⅴ Press the key could memorize the present radio frequency, Pressing the key MEM continually will memorize the present radio frequency in different channel The channel of max is 10,Name of channel is 0-9 Ⅵ The volume can be changed by pressing key 11 Operation of Pump: VOL+ SET and OPEN The Button, operates pump 1;The Button PUMP2 operates pump 2;The button PUMP3 operates pump 3 When Circulation cleaning and heating (including preheating) turn on, circulation pump will be working automatically. 12 Operation of lasting circulation cleaning: Press the key at any time to turn on or off the lasting circulation cleaning, work mode is like the preset circulation cleaning. The surfing pumps and blower work for 30 seconds at every 30 minutes. Ozonizer works for 15 minutes at every 105 minutes, and repeat in this program. Once any surfing pumps or blower pump be start, the ozonizer without working. The ozonizer can not work if the circulation pump is without working. IMPORTANT: Please ensure that the ozone function is not in use whilst bathing in the spa. 13 Operation of spa lights: Press the button to control the ON/OFF of the LED lights and the Fiber optic lights. 14 Setting the constant Temperature Settings: 9

1) Pressing the button will start the constant temperature heating. 2)With the setting above, the circulation pump will work automatically. 3) If the temperature is set at 35, when the water temperature reaches or exceeds 36, the heater will be turned off automatically and the circulation pump will stop after 5 seconds. When the water temperature reaches or is lower than 34, the heater will start up again. 4) In the case of an error the LCD shows E1. If this happens, the thermostatic heating system will NOT be available, the heater doesn t work. 15 Operating the Air Blower: Press controls the blower. 16 Fahrenheit & Celsius Temperature shift: In the status of Power off pressing the key can change the mode of Fahrenheit & Celsius degree. 17 When there is no water in the spa. All water pumps and heating system can not start up. However the corresponding signals will flash on the LCD. 18 Prevent freezing function: The heater & circulation pump will work automatically once the water temperature is below 5, when the water temperature is reach at 10, heating will stop. This function is only available while the spa is on normal power supply. IV Electric parameters 1 Performance index: Rated voltage: 220V/50Hz Maximum working current:60 A/220V-240V~ Voltage-resistance:1250V/1 minute without penetration Isolative resistance: 10MΩ Water resistance grade:ipx5 Electric shock resistance:first grade (2) Output loading index Heater: AC220V/3KW x 1 Surf Water pump: AC220V/2 HP x 3 water pump: AC220V/1HP x 1 Air pump: AC220V/0.7kw x 1 spa light: AC12V/5W x 1 Ozone:Ozone: 12V/15W 1 water Radio:1) Frequency Range: FM: 87.0~108.0MHz 2) Maximum Output Power: 10W 3) Speaker:8Ωdamp proof speaker 5.Warning Information a. Means for disconnection must be incorporated in the fixed wiring in accordance with the wiring rules. b. If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified persons in order to avoid a hazard. 10

c. This appliance is not intended for use by persons (including children) with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given supervision or instruction concerning use of the appliance by a person responsible for their safety. d. Children should be supervised to ensure that they do not play with the appliance. e. Details concerning cleaning and other maintenance f. Maintenance of water purity, especially PH values and chlorine concentrations. g. Cleaning and disinfection h. Use and installation of a cover. i. Disposal of water j. Precautions to avoid damage due to water freezing k. Precautions to avoid damage when the appliance is left empty for extended period. 2.2 Sub-clause 7 The installation instruction shall state the substance of the following: - Earthed appliances must be permanently connected to fixed wiring; - The appliance should be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30 ma. - The floor has to be capable of supporting the expected load. - An adequate drainage system has to be provided to deal with overflow water. - Details of how to follow the wiring rules, for example, specifying that parts are installed in the correct zone and that equipotential bonding is carried out. 1 DANGER:RISK OF ELECTRIC SHOCK,Connect only to a circuit protected by a Ground WARNING Fault Circuit lnterrupter. 2 Grounding is required. The unit should be installed by a qualified service representative and ground. 3 FOR YOUR SAFETY-This product should be installed by a professional service technician,qualified in hydrotherapy bath installation. 4 lt s prohibited to cover the instrument with something while opeating. 5 when using at the first time,be sure there is water in heater pipe before staring. 6 parts containing live parts, except parts upplied with safety extra-low voltage not Exceeding 12V,must be inaccessible to person in the bath; 8 earthed appliances must be permanently connected to fixed wiring; 9 the appliance should be supplied through a residual current device (RCD)having a rated residual operating current not exceeding 30 ma. 10 If the mains cord of this appliance is damaged,it must only bereplaced by our service representative,as special tools and/or parts are required 11

Solutions of Fault Phenomenon Reason How to Solve the problem No power supply 1. The electric leakage switch was breaked off 2. The Fuse be break off 1. Check and eliminate the malfunction, restart the spa 2. Please change fuse No display on control panel LED light not work Ozone not work Displaied E1 FF in control panel being incapable of activate water pump,and water pump icon flashing Heater not work, and heating icon on panel flashing Leakage 1. The plug which connected with the panel loose or disconnected 2. The Panel happened with malfunction 1. Power of the light be break off 2. Fuse be break off 3. light be burn 1. Ozonater burn 2. Fuse be break off 3. Cable of the ozonater be cut off 1. temperature detector be cut off or shortcirculate 2. plug of the temperature detector be nundated by water 1.water not achieve the appointed level 2. water detector not connect well 1. setting water temperature lower then the water temperature 1. silicon plaster not good 2. PVC plaster not good 3. Blow out of the water pipe 1. to connect the plug of the control panel and the main box 2. Change a new control panel 1. To check if cable of the light is well connected with main box or not 2. Change a fuse 3. Change a new lampwick 1. Change a new ozonater 2. change a fuse 3. check if the cable of the main power is connected with the main box or not. 1. Connect the temperature detector 2.Change a new temperature detector 1. To add more water to make it up to the water detector 2. To re-connect the line of water detector 1. set the temperature degrees higher than the water in tub temperature(between 15 and 43 C 1. To remove the jets then re-install one 2. To plaster once again Change water pipe 12

13

14

15