Helps reduce cycle time and increase productivity with advanced SPRAY-CURE technology.

Similar documents
Long lasting unit provided by heavy-duty, corrosion-resistant, galvanized steel construction.


CORAYVAC Helps Reduce Energy Bills and Improve Comfort

Unit Data - RCA 051 RATED IN ACCORDANCE TO AHRI STANDARD

BANANZA. B-Series Direct-Fired Heating, Cooling And Pressurization Systems. Equipment Specifications

STR-Series Indirect-Fired Air Turnover Units

Combat. DF-Series Direct-Fired Heating, Cooling and Pressurization Systems. Equipment Specifications

GLOBAL FINISHING SOLUTIONS

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE COOLING-ONLY 100% OUTSIDE AIR VERSION Telephone:

ADDISON SEQUENCE OF OPERATION FOR ALC CONTROL AIRSOURCE HEATPUMP 100% OUTDOOR AIR VERSION Telephone:

Installation, Operation & Service Manual

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS DU/DUH DUAL OUTPUT RANGE INFRARED TUBE HEATERS

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS SL/SLV SIRIUS LINEAR RANGE HIGH EFFICIENCY CONTINUOUS INFRARED SYSTEMS

NRG Control WARNING. Energy Saving Control for Combat Warm Air and Blackheat Radiant Heating Equipment Installation, Operation and Service Manual

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

LARGE CAPACITY HEATERS

Direct Gas-Fired Make-Up Air

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

Equipment Specifications

Indirect Gas-Fired Make-Up Air

Heating safely with gas-fired infrared heaters

Direct Fired Heater Model AD Specification

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

CB/CF. Series CONDENSERS AND CONDENSING UNITS. Features:

7 sizes: 55,000, 80,000, 110,000, 155,000, 199,000, 285,000 & 399,000 Btuh. One of a kind design from the inside, out!

System Control. Installation, Operation & Service Manual WARNING. Installer

The H Series. Pure and Simple Solutions. HTLV Space Heating

Modular Heating & Ventilating Unit Model IGX-HV

TIO THE LEADER SPRAY BOOTH APPLICATIONS

A-8-01 Typical questions and answers on the boiler specifications on tender and boiler contract documents

NESCO LIMITED PAINTING SYSTEM DIVISION SHOT BLASTING PRETREATMEN PAINT BOOTH ABOUT US: PAINT BOOTH

SECTION 7: OPTIONAL HEATER ACCESSORIES. Step Reflector Joint Installation. Step Reflector Joint Detail. FIGURE 19: Reflector Joint Detail

AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

Design Specifications for Panda 900A Car Spray Booth

Air Make-Up Units. Product Line Overview & Capabilities

MODEL ADF/ADFH 300 and 500 INDOOR/OUTDOOR DIRECT-FIRED GAS HEATING/MAKEUP AIR SYSTEM FOR INDUSTRIAL & COMMERCIAL APPLICATIONS

GETTING THE MOST OUT OF HYDRONIC HEATING SYSTEMS

Suggested Specifications Prestige Excellence 110

SAMPLE SPECIFICATION FOR RIELLO ARRAY MODULATING BOILER

Power Flame Incorporated

1.03 DELIVERY, STORAGE, AND HANDLING Heater will be stored to secure against damage and handled per manufacturer s recommendations.

Flame relay units are necessary in most industrial combustion systems. These flame relay models are capable of meeting most application needs.

Industrial Space Heating Direct Gas-Fired Heating. Greenheat 50/50 Recirculation

GAS-FIRED PRESSURIZED LOW INTENSITY INFRARED HEATERS SERIES TLP

Up To 99% Thermal Efficiency HIGH EFFICIENCY COMMERCIAL BOILERS WITH MODBUS PROTOCOL, CASCADING SEQUENCER AND FRONT-END LOADING CAPABILITY

Tradesman Tradesman K Norseman Workman Sun Blast Premier Foreman Torches. New

10 : 1 Turndown Ratio

COMMERCIAL GAS WATER HEATERS

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

Engineering Submittal Data PPRTH Patio Radiant Tube Heaters.

RIELLO ARRAY. High Efficiency Condensing Boiler MBH.

Field Start-Up Sheet Direct Fired Gas Equipment

AFUE 95% Heating Input 50,000 to 200,000 Btuh

Bryan Flexible Water Tube. Ultra-High Efficiency Condensing Hot Water Boilers. 3,000,000 BTUH Natural Gas Fired

Conquest. Condensing Gas Water Heater. 199 to 300 MBH 100 Gallon Tank 15-year Warranty. PVI.com

Air Replacement Systems

PART NO. COMBUSTION AIR CAP

Engineering Bulletin. Gas Heat. for M-Series and T-Series Climate Changer Air Handlers CLCH-PRB010-EN. March 2004

CLEARANCES TO COMBUSTIBLES

Fuel Conversion Kit Instructions

INSTALLATION, OPERATION & MAINTENANCE MANUAL INDIRECT GAS-FIRED DUCT FURNACE

Click Here To View Item at

DCC Series. Submittal Data Form 15- & 20-TON, THREE-PHASE PACKAGED AIR CONDITIONERS UP TO 11 EER

GUIDE SPECIFICATION ADVANCED RADIANT SYSTEMS KMI GoGas RANGE HIGH EFFICIENCY, HIGH INTENSITY INFRARED HEATERS

OPERATIONS MANUAL 5 LITER LPG GAS TANKLESS WATER HEATER C AMPER SERIES

VENTING VENTING OF INDIRECT GAS FIRED AND OIL FIRED HEATING APPLIANCES INDOOR GRAVITY VENTED UNIT HEATERS AND PACKAGED SYSTEMS

DIVISION WALL-HUNG STAINLESS STEEL HEATING BOILERS

Advanced Heating and Hot Water Systems

ADF/ADFH 300 and 500

DIVISION FINNED WATER-TUBE WATER HEATERS

48TM GAS HEATING/ELECTRIC COOLING UNITS

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

A. Product Data: Include rated capacities, furnished specialties and accessories.

HVAC. Air Blowers Fans Forced Air Heaters Heating Cables & Insulation Infrared & Radiant Heaters

ONQUEST. Featuring... Condensing Water Heater. Requires no tank linings or heat exchanger linings. Requires no anodes of any type. 10- year warranty.

Bosch. Gas Condensing Boiler. Applications Manual. 100, 151 Combi Boiler 57, 100, 131, 151 Heating Boiler

SECTION AIR DOORS

DCG Commercial. Submittal Data Form

U n i t H e at e r s

WATER HEATERS / BOILERS GWB8-E. Gas-Fired Hot Water Boiler PRODUCT SPECIFICATIONS. AFUE up to 83.9% Heating Input 50,000 to 299,000 Btuh

GAS-FIRED HIGH INTENSITY INFRARED HEATERS

G71MPP WARNING. WARNING Sharp edges. Be careful when servicing unit to avoid sharp edges which may result in personal injury. Service Literature

Guide Spec Summary. Option List. Date: 05/21/2001. EarthWise VAV Terminal Units Full Spec. Prepared by: Phone Number: Prepared for:

2012 Catalog Version AUG 2012 Noritz America Corporation. All rights reserved.

Suggested Specification: Benchmark 1.5 Low NOx Gas-Fired Hydronic Boiler(s)

Rheem Prestige Series Two-Stage Downflow Gas Furnace equipped with the Comfort Control 2. System. RGLE- Series 80% A.F.U.E. Input Rates kbtu

OTFAMU Fresh Air Make Up System For Chilled Water OPERATOR S MANUAL. Technicold Marine Systems

48TF GAS HEATING/ ELECTRIC COOLING UNITS

Omega II SUBMITTAL DATA. Pre Engineered Packages. Products by: COMBUSTION RESEARCH CORPORATION PROJECT: LOW-INTENSITY INFRARED HEATING SYSTEMS

ENVI Boiler Controller

SUPER HIGH EFFICIENCY WATER HEATERS SUPPLEMENT TO INSTRUCTION MANUAL P/N (Replaces pg. 2 in instruction manual.) CONGRATULATIONS!

Air Replacement Systems

Power Flame Incorporated

Crossover. Hybrid Water Heater. High Efficiency. Advanced Heating & Hot Water Systems.

Weil-McLain part numbers are found in Weil-McLain Boilers and Controls Repair Parts Lists.

MERIT SERIES Downflow

USER S INFORMATION MANUAL

CONDENSERS AND CONDENSING UNITS

Transcription:

BANANZA 100% Thermal Efficient, Direct-Fired, Make-up Air Systems For Ventilation, Heating and Curing in Paint Booths and Finishing Areas SPRAY-CURE B-Series Helps reduce cycle time and increase productivity with advanced SPRAY-CURE technology. Long lasting unit provided by heavy-duty, corrosion-resistant, galvanized steel construction. Can facilitate improved operation and paint job quality through pressurization. Easy maintenance of blower, motor, drives and burners with large access panels. Can meet shop space demands with array of configurations. Heaters are listed to ANSI Z83.25/CSA 3.19 direct gas-fired process air heaters. Helps reduce energy costs due to 100% thermal efficiency. 1.800.255.3416 www.bananza.com

BANANZA B-Series with SPRAY-CURE Designed for the unique needs of the finishing market, BANANZA B-Series air handlers with SPRAY-CURE technology help maintain a pressurized condition in the finishing facility or paint booth. Introducing a controlled amount of fresh, tempered air, can keep dirt and debris out, helping reduce finishing time while improving productivity, operation and finishing quality. The air handlers are sized and designed according to the exhaust rate requirements of the paint booth or finishing facility. SPRAY-CURE units help enhance the performance of the exhaust and filtering system. During the curing cycle, super-heated air is circulated to speed cure time and improve efficiency of the finishing process. Air handlers utilizing recirculation, can deliver high temperatures in cure mode and aid in reduced fuel usage. Additional energy savings can be realized by the unit s 100% thermal efficiency. Proper booth pressurization in the finishing facility or paint booth, helps minimize heat loss. Model B-650 B-1000 B-2000 B-3000 CFM 5,000-10,000 11,000-14,000 16,000-25,000 27,500-40,000 Output [MBH]* NG 594-1,188 1,306-1,663 1,900-2,970 3,267-4,752 LPG 486-972 1,069-1,360 1,553-2,430 2,673-3,888 * 1MBH = 1,000 Btu/h. Output range indicated at maximum temperature rise, the maximum rise for the B-650 to B-3000 is NG/LPG=110/90 Degree F at 100% outside air. 100% Thermal Efficient in Curing of Paint, Coatings and Finishes for: Automotive Paint Booths Industrial Components and Parts Finishing RV, Truck, Boat/Marine Paint Booths and Buildings Aircraft Parts Finishing and Paint Hangars Cabinets and Woodwork Finishing and Varnishing Furniture Finishing and Varnishing

SPRAY-CURE Remote Panels to Meet a Varie A variety of pre-engineered controls help customize the BANANZA unit's operation for a specific process. Remote Panel Basic II (Cure) Basic II (Spray) Digital Dual # Used for Curing Paint Yes No Yes Used for Spraying Paint No Yes Yes Discharge Air Temperature F ( C) 120-170 (48.9-76.7) Single analog temperature selection dial. 55-90 (12.8-32.2) 60-90 (15.6-32.2 80-180 (26.7-82. Discharge temperature rem Two temperature selection digital display. Fan ON/OFF Switch Burner ON/OFF Switch Light ON/OFF Switch Yes Yes No SPRAY-CURE Mode Selector Switch No No Yes Indicator Lights Other Controls No No Adjustable speed controls f fan in spray and cure m Burner Flame Modulated by discharge tempe Nema 1 Enclosure FAN ON/BURNER OFF Mode FAN ON/BURNER ON Mode FAN/BURNER ON - Spray Mode FAN/BURNER ON - Cure Mode Blower can operate without burn Air handler operates continuously, supplying No Yes Yes Yes No Yes

ty of Applications 1 Dual #2 Digital 60-160 Deluxe Digital ) / 2) 55-90 (12.8-32.2) / 120-170 (48.9-76.7) ains constant as selected on temperature selection dial. dials with Two analog temperature selection dials. or exhaust ode. 60-160 (15.6-71.1) Single temperature selection dial with digital display. 60-90 (15.6-32.2) / 80-180 (26.7-82.2) Two temperature selection dials with digital display. Yes No Yes Adjustable purge and cure timers. Adjustable speed control for exhaust fan and booth pressure gauge. Optional: burner lockout indicator light, remote reset push button and check filter indicator light. Adjustable speed controls for exhaust fan in spray and cure mode and booth pressure gauge. Adjustable timers for purge, cure and cool down. Optional: burner lockout indicator light, remote reset push button and check filter indicator light. rature control, governed by remote temperature selector. er. Air handler operates continuously, supplying make-up air. heated make-up air and maintaining constant discharge temperature.

Installation Options BANANZA B-Series air handlers with SPRAY-CURE technology are available in flexible configurations, helping allow for mating to various finishing facilities or paint booths. Units can be mounted indoors or outdoors (building rooftop or side wall locations) and can be used with down draft, semi-down draft and cross draft spray booths. These units can be ideal for retrofit and replacement of old or inefficient units. Paint prep stations can also utilize direct-fired make-up air. Roof Mounted, Horizontal, Bottom Discharge Roof Mounted, Horizontal, Bottom Discharge Booth Mounted, Horizontal, Bottom Discharge Ceiling Suspended, Horizontal, End Discharge Pad Mounted, Horizontal, Top Discharge Pad Mounted, Upright, Side Discharge

Thank you for your business! This product is not for residential use. This document is intended to assist licensed professionals in the exercise of their professional judgment. Bananza 1100 Seven Mile Road NW Comstock Park, MI 49321 Telephone: +1.616.726.8800 Toll Free: 800.255.3416 Fax: +1.616.784.0435 www.bananza.com 2017 Roberts-Gordon LLC All rights reserved. No part of this work covered by the copyrights herein may be reproduced or copied in any form or by any means graphic, electronic, or mechanical, including photocopying, recording, taping, or information storage and retrieval systems without written permission of Roberts-Gordon LLC. Printed in U.S.A. BNSCBNA 0217 Rev D