COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE

Similar documents
Wire and Cable The Industry Standard for Rugged, Reliable Performance

Tether and Umbilical Cables for Remotely Operated Vehicles

Introducing Hermaphroditic Blade and Receptacle Connector

FTTX Solutions Mini Rapid Fiber Distribution Terminal (RDT)

Introducing SlimSeal SSL Connector

Z-PACK TinMan 85 ohm Connector Overview

AUTOMOTIVE MINIATURE WIRE (AMW)

SOLARLOK Interconnection System Installation Manual

PlanarMag Product Technology

DEUTSCH 369 Series PCB-Mount Connectors Compact, Lightweight In-Line and Panel-Mount Connectors for Printed Circuit Board Applications

Quick Reference Guide Barrier Strips

Introducing Solar Identification Labels

QUADRAX D-SUB CONNECTORS

Pin, Spool & Strain Insulators

Tether and Umbilical Cables for Remotely Operated Vehicles

S200 SHIELD TERMINATORS

ENERGY /// MINING SOLUTIONS MINING SOLUTIONS RUGGEDIZED HIGH PERFORMANCE PRODUCTS

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

ENERGY /// UNDERGROUND DISTRIBUTION UNDERGROUND DISTRIBUTION MEDIUM AND LOW VOLTAGE POWER PRODUCTS

HARTMAN Smart AC Contactors

APPLICATIONS. Wireless Communications systems. (LAN, GSM, PCS, WCDMA, UMTS) Remote measuring equipment

Copper LAN cable. This specification describes the general requirements for AMP NETCONNECT* copper LAN cable.

Introducing Low Voltage DC Grid Interconnects

/Oct/2014 Rev B

GLOW WIRE TESTING FOR THE APPLIANCE INDUSTRY

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Multi-Core Fire Resistant Cable

EVERCLEAR Mini Multi-Lane High Speed Interconnects & Cable Assemblies

Universal Connectivity Platform A Modular Approach to Infrastructure Design

Insulation and Protection Enhancing the Reliability of Overhead Power Systems

Raychem Elastomeric Medium Voltage Push-on and Cold-shrink Applicable Terminations TFTI/TFTO

Compact Module. Category 6A FTP Cabling System 1.1

Your Pick... One Solution

Product Specification CAT 6 UNSHIELDED PATCH CORDS

HEAT SHRINK CABLE ACCESSORIES: A 40 YEARS PROVEN TECHNOLOGY FOR APPLICATIONS IN HARSH ENVIRONMENTS

LOW POWER AND SIGNAL APPLICATION GUIDE APPLIANCES /// LOW POWER & SIGNAL APPLICATION GUIDE

Your Partner for Custom Interconnectivity Solutions. ISO 9001:2008 AS9100C:2009 ISO 13485:2003 ISO 17025:2005 Qualified

Mosaic TM LCS2 Cat. 6A STP RJ 45 socket

C6 Premium. C6 Premium Copper Systems from Infinique is premium performing Class E / Category 6 Data Communication

TE Connectivity's AMP NETCONNECT Cable Management

Reliable solutions for electrified railway systems

Introducing Inverted SMT Thru Board Connector

INTERNATIONAL STANDARD

/Oct/2014 Rev E

Arteor TM LCS2 Cat. 6A STP RJ 45 socket

NEMA Standards Publication WC Standard for Controlled Impedance Shielded Twisted Pairs in Internal Electrical Cable

Standard and Customized Hand Tool Kits

WILDLIFE AND ASSET PROTECTION PRODUCTS

Raychem heat-shrinkable medium voltage terminations IXSU-F/OXSU-F for indoor and out door applications for polymeric cables up to 42 kv

CONTACTORS FOR AEROSPACE GROW SMARTER AND MORE CAPABLE

AMP SUPERSEAL 1.5 SERIES Connectors

Bowthorpe EMP surge arrester Distribution metal oxide surge arrester DA0 Series, (IEC)

TE Connectivity Product & Application Guide

Industrial Fiber Optic Cables, LSZH Corrugated Armored Cable, Fibers

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES

Undercarpet Cabling Products Undercarpet Power, Voice and Data Distribution

Cat 6 Unshielded Patch cords

TE S RAYCHEM PLUG-IN TERMINATIONS (RPIT) INNER CONE SYSTEMS FOR SWITCHGEARS AND TRANSFORMERS UP TO 52 kv

NEMA Standards Publication WC Standard for Controlled Impedance in Internal Electrical Cable

Signal Connectors for Topside and Subsea Applications

KILOVAC K1K High-Voltage Contactor

LOW VOLTAGE HEAT SHRINK JOINTS TECHNOLOGY CONNECTING YOUR NEEDS TO TOMORROW S NETWORKS

CAT5E DIRECT BURIAL (FLOODED CORE) 24AWG, UTP, 4 PAIR, SOLID 1000 PULL BOX /CMXF

TE CONNECTIVITY <fiber count> <fiber type> <flame rating> MM/YY SO<shop order number> XXXXX FEET

INTERNATIONAL STANDARD

Nuclear Power Plant LSZH Cable Overview

RAYCHEM SCREENED SEPARABLE CONNECTORS RSTI FOR SWITCHGEARS AND TRANSFORMERS IN MEDIUM VOLTAGE DISTRIBUTION NETWORKS

Sensor and transducer cables

Universal Connectivity Platform

Quick Reference Guide: Connectors for Mobile Devices

IEC ; EN ; DIN VDE ; CEI 20-37/2-1 ; BS * No Corrosive Gas Emission

Energy Division. Bowthorpe MV Surge Arresters OCP, Open Cage Polymeric series

RAYCHEM MEDIUM VOLTAGE

Cat 6 Shielded Patch cords

ENERGY /// TE S RAYCHEM CABLE CLAMPS TE CONNECTIVITY S (TE) RAYCHEM CABLE CLAMPS

Qualification Test Report. AMP-TWIST Series Jacks for Class EA systems

Fiber Optic Distribution Cables (6-144 Fibers)

HPF 1.2 NEW INTERCONNECTION SYSTEM FOR EXTREME VIBRATION REQUIREMENTS IN THE VEHICLE

INDUSTRY /// RAIL T-CONNECTOR RSTI-68R-HT RSTI-CC-68R-HT RAIL APPROVED T-CONNECTORS FOR ROLLING STOCK- TYPE C INTERFACE

Wire and Cable. For more information on these Tyco Electronics products, visit the following website:

Comtran Cable. Hub-LINK Cables for Transit Applications

TE CONNECTIVITY S CYLINDER HEAD WIRING SOLUTIONS FOR INDUSTRIAL & COMMERCIAL VEHICLES WE GO TO EXTREMES TO MAKE EVERY CONNECTION COUNT

Space Products Mission-Critical Reliability

Belden Infinity C-TC+ Cables for Extreme Flexing

RAIL /// WIRE & CABLE WHERE THE BEST IDEAS IN RAIL BEGIN

CHOOSING CORE MATERIALS FOR AEROSPACE APPLICATIONS

High Density Optical In-Line Dry-Mate Connector (ILC) High Performance Multichannel Fiber Optic Connectors

METRIC. Wire and Cable. Wire and Cable. Table of Contents. Dimensions in this section are millimeters over inches

IDENTIFYING TRAY CABLES FOR YOUR NEXT INSTALLATION A WHITE PAPER

RENEWABLE ENERGY. Durable solutions for maximum efficiency and the promise of reliability. ENERGY PIONEERS IN POWER SOLUTIONS

Caledonian Flame Retardant Coaxial Cables

S Low loss coax cables with foamed PE

DEUTSCH D3 SERIES PCB CONTACTS FOR SERIES III-STYLE CONNECTORS

PANDUIT 4-PAIR & MULTIPAIR COPPER DATA CABLE PLENUM RATED

Perimeter Product Overview. Effective protection for your business

Total Fire Solutions. Includes BS 8519 and the updated BS :

Arteor TM LCS2 Cat. 6A UTP RJ 45 socket

Flexible Heaters. of Silicone Rubber & Kapton

FEB. 17 Rev. A1

Note: Asterisk ** denotes that the standard compliance is optional, depending on the oxygen index of the PVC compound and the cable design.

Transcription:

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE Robert Moore, Principal Engineer High Speed Specialist AEROSPACE, DEFENSE & MARINE /// WHITE PAPER -

COMMERCIAL PROTOCOLS AND AEROSPACE CABLING: FINDING THE RIGHT BALANCE Robert Moore, Principal Engineer High Speed Specialist Commercial Protocols and Aerospace Cabling: Finding the Right Balance Commercial protocols in aerospace applications present designers with challenges of balancing the standard against special needs of the application. In the physical layer, the cables used for Gigabit and 10 Gigabit Ethernet, USB, IEEE 1394 and others are a prime example of this balancing act. The standards for these protocols detail electrical and structural requirements for the cables. One goal of standards is to characterize cables with enough specificity that they can be confidently plugged into the application. For commercial applications, this approach works admirably. The additional concerns for aerospace applications lead designers to reconsider this convenient plug-and-play approach. Their primary driver is reducing size and weight at every opportunity in the aircraft. As the amount of data in both aircraft operation and passenger services increases dramatically, so does the number of conductors needed to carry the data. In aggregate, commercial cables make an attractive target for size and weight reductions. At the same time, industry-standard cables may not possess the desired mechanical or environmental performance, especially the demanding requirements for low smoke generation, toxicity and flammability in closed spaces where safe exit may be difficult or impossible. Figure 1. Aerospace applications are increasing using well-established commercial protocols for high-speed data transfers. (Source: TE Connectivity) AEROSPACE, DEFENSE & MARINE /// WHITE PAPER PAGE 2

The Case for Cat Cable Consider a Cat 5e cable for Gigabit Ethernet. Its typical commercial construction is a 24 AWG solid bare copper conductor with polyethylene insulation and PVC jacket. The ANSI/TIA 568-C.2 standard defines electrical requirements for attenuation, insertion loss, return loss, crosstalk and a host of other criteria. For our purposes, we will focus on insertion loss. This characteristic largely determines allowable cable distances (assuming crosstalk goals are met). Consider a typical progression in defining a Cat 5e cable for aerospace. Each step tends to increase both attenuation and insertion loss, effectively reducing the allowable cable length. TE Connectivity works closely with aerospace designer to craft cabling solutions that meet the goals of the application protocol and the requirements for size, weight and robustness. Stranded conductors give greater flexibility in installing and routing cables in space-constrained aircraft. While the 568- C.2 standard recognizes stranded conductors for short patchcords, it specifies solid conductors for backbone needs because of their lower insertion loss. The change from solid conductor to stranded conductor allows for 20% increase in insertion loss, which would result in a 20 percent decrease in the maximum cable run length. Many aerospace applications specify silver-coated copper alloy conductors because of their high tensile strength. Moving from pure copper to a copper alloy can increase insertion loss by another 10 percent, depending on the cable design. Smaller conductors save weight, which explains the trend toward 26 AWG and even 28 AWG. Figure 2 shows practical distances for different conductors. Additional size and weight reductions can also be obtained by using thin-wall, lower permittivity dielectrics and tougher jacket materials. Figure 2. Size- and weight-saving cable configurations meet the need for high-speed Ethernet over reduced distances. (Source: TE Connectivity) Cat 6A cable, to enable 10G Ethernet, presents similar tradeoffs. AEROSPACE, DEFENSE & MARINE /// WHITE PAPER PAGE 3

The Case for USB USB 2.0/3.0 applications present the opposite situation from Cat 5e Ethernet applications. Designers want to extend transmission distances beyond the standard 5 meters for USB 2.0. (USB 3.0 does not specify a maximum cable length, but the practical length for commercial cables is 3 meters.) Since USB supports both power and data, designers need to consider both voltage drop in the power line and insertion loss in the data lines. An additional concern is delay time: 26 ns end-to-end or 5.2 nanoseconds per meter for the cable in USB 2.0. Extending data lengths for USB involves both the conductor size and insulation type (as well as solid or foamed). While a larger conductor can lower insertion loss, velocity of propagation is more critical to meet the delay requirements. A high-velocity insulation will allow longer distances without adding to the delay time. Low-density PTFE and foamed FEP offer velocities of propagation about 13 to 25 percent faster than that possible with the polyethylene used in commercial USB cables. Discounting insertion loss for the moment, low density PTFE or foamed FEP can extend distances to 6.3 meters while still meeting delay time requirements. Figure 3 shows examples of how alternative insulations can extend USB cable distances. Insulation Velocity of Propagation (%) USB 2.0 Cable Distance PE 66 5 m LD-PTFE 75-83 5.68 6.3 m FFEP 75-83 5.68 6.3 m Figure 3. Insulation choices affect possible USB cabling lengths. (Source: TE Connectivity) The Case for IEEE 1394 IEEE 1394, as a data backbone, is beginning to take hold in the aerospace market. System designers are removing the components that supply power to the end device or sensor. Quadraxial cable constructions that only provide the two data pairs provide the smallest, lightest weight cable configuration. Depending on the conductor AWG, maximum cable runs can range from 50 to 80+ feet. Power to the device is then supplied by separate wires appropriately sized to meet input voltage requirements. Achieving Ruggedness Insulation and jacket choices also affect the ruggedness of the cable. Standards-compliant cables can be fabricated with a range of polymers to meet special requirements for chemical/fuel resistance, extended temperatures, low outgassing, toxicity, flame characteristics, flexibility and other factors. In order to meet the demanding smoke, toxicity, flammability and other environmental requirements imposed by aerospace applications, the materials are more expensive than those used in the commercial constructions. Off the Shelf or Engineered? While standards such as ANSI/TIA 568 or USB play a valuable role in allowing applications to be deployed in a cookiecutter fashion, they can be viewed as either mandates or recommendations. For most users, they are mandates. Knowing that a cable meeting all Cat 5e specs carries the assurance it will work within the application guidelines. A longer view, however, is that channel performance trumps component performance: the critical issue is to deliver the signal with the signal integrity required by the receiver. Standards exist to ensure this delivery. Aerospace designers will accept some modification in the performance specifications so long as the overall application requirements are met. AEROSPACE, DEFENSE & MARINE /// WHITE PAPER PAGE 4

Such cables may be readily available or they may be semi-custom. TE, for example, has extensive experience in creating cables to help meet specific goals. Such experience allows us to balance the various tradeoffs involved in meeting not only high-speed protocol requirements, but the need for smaller, lighter cables that also withstand application hazards. Author s Bio Robert Moore is Principal Engineer Wire and Cable Development for TE Connectivity, Global Aerospace, Defense & Marine. He has more than 27 years experience working on wire and cable products for aerospace, marine and ground systems, as well as data communication over copper and signal integrity. te.com MULTIGIG RT and MULTI-BEAM XLE are trademarks of the TE Connectivity Ltd. family of companies. Legal. TE Connectivity, TE connectivity (logo) and Tyco Electronics are trademarks of the TE Connectivity Ltd. family of companies and its licensors. While TE Connectivity has made every reasonable effort to ensure the accuracy of the information in this document, TE Connectivity does not guarantee that it is error-free, nor does TE Connectivity make any other representation, warranty or guarantee that the information is accurate, correct, reliable or current. TE Connectivity reserves the right to make any adjustments to the information contained herein at any time without notice. TE Connectivity expressly disclaims all implied warranties regarding the information contained herein, including, but not limited to, any implied warranties of merchantability or fitness for a particular purpose. The dimensions in this document are for reference purposes only and are subject to change without notice. Specifications are subject to change without notice. Consult TE Connectivity for the latest dimensions and design specifications. Tyco Electronics Corporation, a TE Connectivity Ltd. Company. All Rights Reserved.9-1773465-3 6/12 Original 2012 AEROSPACE, DEFENSE & MARINE /// WHITE PAPER PAGE 5