BARD WOUND DRAINAGE CLOSED WOUND SUCTION GRAVITY DRAINS SUMP DRAINS Products to meet your different procedural needs Advancing Lives and the Delivery of Healthcare.
Channel s The Bard Channel is a radiopaque closed wound suction drain distinguished by four free-flowing channels that offers optimized drainage for any procedure. Not made from natural rubber latex, Single-use, 10/case. 1. 2. 3. 4. Improves drainage with less clotting Minimizes tissue invagination Reduces pain and tissue trauma for the patient upon removal Features sizes for every surgery Size Part Number Size Fr. In. mm Shape Fluted Trocar 072186 10 1/8 3.2 Round Full 072187 10 1/8 3.2 Round Full 1/8 in 072221 10 1/8 3.2 Round 3/4 1/8 in 072226 10 1/8 3.2 Round Hubless Full 072227 10 1/8 3.2 Round Hubless Full 1/8 in 072188 15 3/16 4.7 Round Full 072189 15 3/16 4.7 Round Full 3/16 in 072223 15 3/16 4.7 Round 3/4 3/16 in 072228 15 3/16 4.7 Round Hubless Full 072229 15 3/16 4.7 Round Hubless Full 3/16 in 072190 19 1/4 6.3 Round Full 072191 19 1/4 6.3 Round Full 1/4 in 072192 19 1/4 6.3 Round Full 1/4 in 072225 19 1/4 6.3 Round 3/4 1/4 in 072230 19 1/4 6.3 Round Hubless 3/4 072231 19 1/4 6.3 Round Hubless 3/4 1/4 in 072234 24 5/16 8.0 Round Hubless Full 072290 28 3/8 9.3 Round Hubless Full 072292 32 7/16 10.7 Round Hubless Full 072328 28 3/4 9.3 Round Hubless Full, Ext. Length 072332 32 7/16 10.7 Round Hubless Full, Ext. Length 072210 n/a 1/4 7 Flat 3/4 072211 n/a 1/4 7 Flat Full 072212 n/a 1/4 7 Flat Full 1/4 in 072216 n/a 1/4 7 Flat 3/4 1/4 in 072213 n/a 3/8 10 Flat 3/4 072214 n/a 3/8 10 Flat Full 072215 n/a 3/8 10 Flat Full 3/8 in 072217 n/a 3/8 10 Flat 3/4 3/8 in 072235 24 5/16 8.0 Round Hubless Full
Wound s Silicone s - Round Perforated silicone round drains are available with and without trocars in an assortment of sizes. s feature a radiopaque stripe for x-ray detection. Not made from natural rubber latex, Single-use, Sterile. 10/case. Part Number Shape Size (in) Hole Pattern Perforation Trocar 0070200 Round 3/32 10 in End 0070210 Round 1/8 10 in End 0070220 Round 3/16 10 in End 0070230 Round 1/4 10 in End 0070310 Round 1/8 10 in End Yes 0070320 Round 3/16 10 in End Yes 0070330 Round 1/4 10 in End Yes 0070710 Double Round 1/8 12.25 in Mid Yes 0070720 Double Round 3/16 12.25 in Mid Yes 0070730 Double Round 1/4 12.25 in Mid Yes Silicone s - Flat Hubless silicone flat drains are available in 7mm and 10mm sizes with 3/4 and full perforations. s are radiopaque for x-ray detection. Not made from natural rubber latex, Single-use, sterile. 10/case. Part Number Shape Size (mm) Perforation Trocar 0070370 Flat- Hubless 10 3/4 No 0070430 Flat- Hubless 7 Full No 0070440 Flat- Hubless 10 Full No 0070360 Flat-Hubless 7 3/4 NO PVC s Siliconized PVC round drains with 12 in. hole pattern and radiopaque stripe. Available with or without trocar in an assortment of sizes. Not made from natural rubber latex, Single-use, sterile. 10/case. Part Number Shape Size (in) Perforation Hole Pattern Trocar 0034660 Double Round 1/8 Mid 12.5 in No 0034670 Double Round 1/4 Mid 12.5 in No 0034680 Double Round 3/16 Mid 12.5 in No 0080700 Double Round 3/32 Mid 12.5 in Yes 0080710 Double Round 1/8 Mid 12.5 in Yes 0080720 Double Round 3/16 Mid 12.5 in Yes 0080730 Double Round 1/4 Mid 12.5 in Yes
Evacuators Silicone Bulb Evacuator Kits 100cc evacuators offer lightweight, low level suction. Available with round or flat drain, with or without trocar. Not made from natural rubber latex, Single-use, sterile. 20/case. Part Number Evacuator Shape Length Width Perforation Trocar 0071360 100cc Flat Hubless 20 cm 7 mm 3/4 No 0071370 100cc Flat Hubless 20 cm 10 mm 3/4 No 0071430 100cc Flat Hubless 20 cm 7 mm Full No 0071440 100cc Flat Hubless 20 cm 10 mm Full No 0072360 100cc Flat Hubless 20 cm 7 mm 3/4 Yes 0072370 100cc Flat Hubless 20 cm 10 mm 3/4 Yes 0072430 100cc Flat Hubless 20 cm 7 mm Full Yes 0072440 100cc Flat Hubless 20 cm 10 mm Full Yes 0073310 100cc Round 1/8 in End Yes 0073320 100cc Round 3/16 in End Yes Reliavac Evacuator Kits (100cc) 100cc Reliavac PVC evacuators offer a more constant suction profile than silicone evacuators. Bottom emptying port reduces chance of contamination. Available in an assortment of sizes, round or flat drain, with or without trocar. Not made from natural rubber latex, Single-use, sterile. 20/case. Evacuator Part Number Size Suction Material Shape Size Perforation Y Connector Trocar 0085310 100cc Medium (120-140mm Hg) Silicone Round 1/8 in 10 in Yes Yes 0085320 100cc Medium (120-140mm Hg) Silicone Round 3/16 in 10 in Yes Yes 0085360 100cc Medium (120-140mm Hg) Silicone Flat 7 mm 3/4 Yes No 0085370 100cc Medium (120-140mm Hg) Silicone Flat 10 mm 3/4 Yes No 0085380 100cc Medium (120-140mm Hg) Silicone Hubless Flat 7 mm Full Yes No 0085390 100cc Medium (120-140mm Hg) Silicone Hubless Flat 10 mm Full Yes No 0090360 100cc Low (40-80 mm Hg) Silicone Flat 7 mm 3/4 Yes No 0090370 100cc Low (40-80 mm Hg) Silicone Flat 10 mm 3/4 Yes No 0090380 100cc Low (40-80 mm Hg) Silicone Flat 7 mm Full Yes No 0090390 100cc Low (40-80 mm Hg) Silicone Flat 10 mm Full Yes No
Three-Spring Evacuator Kits 400cc Three-spring evacuators provide reliable suction for surgical cases with larger amounts of drainage. Not made from natural rubber latex, Single-use, sterile. 10/ case. Part Number Evacuator Material Size (in) Hole Pattern Y Connector Trocar 0043600 400cc PVC 3/32 12.5 in Yes Yes 0043610 400cc PVC 1/8 12.5 in Yes Yes 0043620 400cc PVC 1/4 12.5 in Yes Yes 0043630 400cc PVC 3/16 12.5 in Yes Yes 0043660 400cc Silicone 1/8 10 in Yes Yes 0043670 400cc Silicone 1/4 10 in Yes Yes Reliavac Evacuator Kits Offers a more constant suction profile than three-spring evacuators, resulting in the potential for improved tissue approximation and reduced risk of hematoma. 400cc Reliavac kits are available in an assortment of sizes, with or without trocar. Single-use, sterile. 10/case. Part Size (in) Hole Number Evacuator Material Shape Pattern Y Connector Trocar 0034600 400cc PVC Round 3/32 12.5 in Yes Yes 0034610 400cc PVC Round 1/8 12.5 in Yes Yes 0034620 400cc PVC Round 1/4 12.5 in Yes Yes 0034630 400cc PVC Round 3/16 12.5 in Yes Yes 0070480 400cc Silicone Round 1/8 10 in Yes Yes 0070490 400cc Silicone Round 3/16 10 in Yes Yes 0070510 400cc Silicone Round 1/4 10 in Yes Yes Reliavac Evacuators Part Number Description Pkg 0034830 Evacuator only (400cc) 10/cs 0070800 Evacuator with Y-Connector (400cc) 10/cs 0070850 Bulb Evacuator with Y-Connector (100cc)- Medium 20/cs 0070900 Bulb Evacuator with Y-Connector (100cc)- Low 20/cs Evacuators Only Offers lightweight low level suction and is easy for a patient to carry. Part Number Evacuator Material Shape Pkg 0070740 100cc Silicone Bulb 20/cs 0071200 200cc Silicone Bulb 10/cs 0070400 400cc Silicone Bulb 10/cs 0043650 400cc PVC 3 Spring 10/cs
Gravity and Sump s Sump s Abramson Triple-Lumen Sump s are used in the peritoneal cavity to remove large volumes of thick exudates. The triple-lumen sheath allows an air vent, suction lumen and irrigation/medication lumen. The sheath that can be left in place as a gravity drain. It has an anti-bacterial filter that allows air to enter without contamination. Not made from natural rubber latex, Single-use, sterile. 5/case. Part Number Material Shape Length (in) Width (in) 0080400 Silicone 3 Lumen 15 5/8 0080420 Silicone 3 Lumen 15 3/8 0080450 Silicone 3 Lumen with Sheath (.67 x 15 ) 15 0.67 Sump Accessories Part Number Component Pkg 0080500 Filter 10/cs Gravity s Penrose s Used to promote drainage in an open surgical wound. Part Number Shape Length (in) Width (in) Pkg/case 0912010 Flat 12 1/4 200/cs Sterile 0912020 Flat 12 3/8 200/cs Sterile 0912030 Flat 12 1/2 200/cs Sterile 0912040 Flat 12 5/8 200/cs Sterile 0912050 Flat 12 3/4 200/cs Sterile 0912060 Flat 12 7/8 200/cs Sterile 0912070 Flat 12 1 200/cs Sterile 0918010 Flat 18 1/4 200/cs Sterile 0918020 For Flat more information 18 about 3/8 the Wound 200/cs age Products Sterile and other 0918030 Bard Flatproducts, please 18 contact 1/2your Bard 200/cs sales Sterile 0918040 representative, call 800.526.4455, or visit www.bardmedical.com. Flat 18 5/8 200/cs Sterile 0918050 Flat 18 3/4 200/cs Sterile 0918060 Flat 18 7/8 200/cs Sterile 0918070 Flat 18 1 200/cs Sterile 0097870 Flat 36 1/4 144/cs Sterile 0097880 Flat 36 5/16 144/cs Non-Sterile 0097890 0097900 0097910 C. Flat R. Bard, Inc. 36 Covington, GA 3/8 30014 www.bardmedical.com 144/cs Non-Sterile Please Flatconsult product 36 labels and inserts 1/2 for any indications, 144/cs contraindications, Non-Sterile hazards, warnings, Flat cautions and 36 directions for 5/8 use. Bard is a 144/cs registered trademark Non-Sterile of C. R. Bard, Inc. or an affiliate. 2009 C. R. Bard, Inc. All Rights Reserved. 0097920 0903-58 Flat R04/09 36 3/4 144/cs Non-Sterile 0097930 Flat 36 7/8 144/cs Non-Sterile 0097940 Flat 36 1 144/cs Non-Sterile For other types of specialty gravity drains refer to the Bard Medical Division Product Catalog.
Accessories Adapters Part Number Fits Fits Pkg 0034850 Reliavac Suction 10/cs 9019500 Silicone 1/8 Round 10/cs 9019510 PVC/Silicone Round/Flat 3/16, 1/4 10/cs 072251 Channel s 24/28 Fr 20/cs 072252 Channel s 32 Fr 20/cs Connectors Part Number Type Connects Size (in) Pkg 0034800 Y PVC 1/8 10/cs 0034810 Y PVC 1/4 10/cs 0070790 Y Silicone Round 3/16,1/4 10/cs 0070790 Y Silicone Flat 10mm, 12.7mm 10/cs 0070770 Universal Claw PVC and Silicone Universal 10/cs 0034800 Trocars Part Number Size (in) Pkg 0034760 1/8 10/cs 0034770 1/4 10/cs 0034780 3/16 10/cs 0070790 0070770 0034760 0034780 0034770
BARD WOUND DRAINAGE CLOSED WOUND SUCTION GRAVITY DRAINS SUMP DRAINS Products to meet your different procedural needs For more information about the Wound age Products and other Bard products, please contact your Bard sales representative, call 800.526.4455, or visit www.bardmedical.com. INDICATIONS: Wound drains are used to remove exudates from wound sites. WARNINGS: An effective closed suction drain system requires maintenance of the system to preserve patency. The drain must not be allowed to occlude nor the reservoir to completely fill; and reservoir suction must be maintained in order for the system to function properly. Verify that the system is functioning properly. If the system is not maintained properly, surgical complications, including hematomas, may result. In the event of occlusion of the drain, all wound drainage via the drain ceases. Careful attention to the drain will minimize the possibility of this problem. If occlusion does occur, the drain can be aspirated by connecting suction to the reservoir outlet or temporarily disconnecting the drain from the reservoir and applying suction directly to the drain. If an air-tight seal between the drain and the skin where the drain emerges is not achieved, the air leak must be rectified or the system must be converted to open drainage. An airtight seal between all system components (drain, adaptor and reservoir) is necessary for proper system function. Leaving the soft silicone elastomer drain implanted for any period of time so as to cause tissue in growth around the drain can interfere with easy removal and may effect the performance of the drain. The surgeon should monitor the patient s rate of wound healing. Evacuators should be used in cardio-thoracic surgery only after the lung is fully expanded and all air leaks have sealed. perforations or channels must lie within the wound or cavity to be drained, otherwise inadequate drainage may result. To avoid the possibility of drain damage or breakage: o Avoid suturing through drains. o s should lie flat and in line with the skin exit areas. o Particular care should be taken to avoid any obstacles to the drain exit path. o s should be checked for free motion during closure to minimize the possibility of breakage. o removal should be done gently by hand. s should not be handled with pointed, toothed or sharp instruments which could cause cuts or nicks and lead to subsequent structural failure of the drain. o Surgical removal may be necessary if drain is difficult to remove or breaks. COMPLICATIONS Complications which may result from the use of this suction drainage system include the risks associated with methods utilized in the surgical procedure, as well as the patients degree of intolerance to any foreign object in the body. The advantages of wound drainage, particularly closed system drainage, are lost if an air-tight seal between the drain and the skin where the drain emerges is not achieved, or if the drain is allowed to become occluded or if the reservoir is not activated properly, doesn t function properly or is not monitored. Evacuators should be emptied and re-activated when required per hospital protocol. In the event an air-tight seal is not achieved, the reservoir will rapidly fill with air from the leak; subsequent drainage to the reservoir will occur only if allowed by gravity and wound exudate forcing the flow. Entry into the reservoir is allowed only by displacement of air in the reservoir by wound exudate flow. In this displacement process, air reflux from the reservoir to the wound can occur and increase the likelihood of back-contamination across the antireflux valve. In the event of drain occlusion by fibrin, clots, or other particulate matter, all wound drainage via the drain ceases. If the reservoir is not emptied when it is full, equilibrium between the drain and reservoir at wound pressure will ultimately occur and drainage from the wound site will cease. When the reservoir and drain are at the same pressure and the reservoir is full of fluid, the likelihood of back-contamination across the anti-reflux valve is increased. When used to drain the pleural cavity in the presence of an air leak, drains must be attached to an appropriate pleural cavity drainage system to prevent tension pneumothorax. CAUTION: Federal (U.S.A.) law restricts this device to sale by or on the order of a physician. Advancing Lives and the Delivery of Healthcare C. R. Bard, Inc. Covington, GA 30014 1.800.526.4455 www.bardmedical.com Bard, Advancing Lives and the Delviery of Healthcare, Davol and Reliavac are trademarks and/ or is a registered trademarks of C. R. Bard, Inc. 2017 C. R. Bard, Inc. All Rights Reserved. 1703-13 BMD/WDDR/1016/0013