Synco living. Train the Tainer. Functions & Operation Safety & Security. Spring 2008 Page 1/32 Train the Trainer - Spring 2008

Similar documents
Synco living. Train the Trainer. Commissioning Safety & Security. Spring 2008 Page 1/21 Train the Trainer - Spring 2008

Synco 900 Operating instructions

Synco 900 Operating Instructions. Edition 1.0 Controller series 1 CE1B2707en Building Technologies HVAC Products

Synco living Operating Instructions. Edition 3.0 Controller series C CE1B2707en Building Technologies

Synco living Operating instructions. Building Technologies

Tebis application software

Central apartment unit

Central apartment unit with QAX913 consumption data acquisition

Application description

CSP-204 CSP-208 CSP-104 CSP-108

Tebis application software

USER MANUAL S203. Controller for three circuits. - control for 2 heating circuits - 1 domestic hot water control. Saving energy, creating comfort

Intruder alarm panel Terxon MX Operating instructions

KNX module for smoke alarm devices Dual/VdS and Q-Label (Order no )

DESCRIPTION OF KEYPAD (Access module with segments)

Use of the application program. Functional description. instabus EIB Application program description. October CO Touch-Manager wave

Applications and Examples

PRESENCE DETECTOR. PD-C360i/8 mini KNX PD-C360i/12 mini KNX / 13 7 REMOTE CONTROL PRESENCE DETECTOR

PRELIMINARY EDITION

BURGLAR ALARM PANEL BS-468/A

ABB STOTZ-KONTAKT GmbH Webinar ABB i-bus KNX Security Module SCM/S

Installer Manual KNX Touchscreen Thermostat

How to define and integrate the Simplex Fire panel in EntraPass

ZM2 OPERATING AND MAINTENANCE INSTRUCTIONS

Ref.1067/032 Ref.1067/042

Running IGSS as an Operator, Part One

Operation manual FR EN NL DE IT. intended for professionals and end users. To be saved for future consultation

Description of the application programme for KNX occupancy detectors version 3.1

COCB_ Circuit Breaker (2 state inputs/ 2 control inputs)

Digiplex LED Keypads User s Manual

Intelligent Security & Fire Ltd

Heating Controller SDC. District Heating Controller DHC 43 OPERATING INSTRUCTIONS

GV2 Series Control Panels

ZERIO PLUS EDA-Z5008, Z5020 & Z5100

Entwicklung + Fertigung + Service: Heerweg 15 D, Denkendorf Tel.: / Fax.: /

CONTROLS INSTRUCTIONS MANUAL ENGLISH

Optional Optional. Min 20W, max 100W. Only resistive load or dimmable (phase control compatible) light bulb. Dimmer optional

Security System. User Guide for the LED Command Center

KNX/EIB - Product database - Application description

E-COMBI EVO E-SYSTEM EVO

OUMAN EH-800 Heating controller USER MANUAL

DOCUMENTATION IPS640

* * Valves, controls + systems. Regtronic RH Installation and operating instructions for the specialised installer

Program version Alarm Control Panel USER MANUAL GDAŃSK. versa_u_en 03/09

CONTROL PANELS for 2 Q2P series ELECTRIC PUMPS

Digiplex System V2.14 / V2.2ACC. Control Panel Programming Guide

THE SOLUTION. MSM-Product family OPERATING MANUAL. A fault annunciator of the. BSM Basic fault annunciator for panel mounting. INFOwww.ees-online.

Planet Super4F.S. User Instructions

1. COMMISSIONING OF THE BOILER en DESCRIPTION FUNCTION BUTTON DESCRIPTION SYMBOL DISPLAY

Products no longer available

D45 System. Colour 7 handsfree indoor handset. Front view

MODEL SF-10 CONTROL OPERATION AND INSTRUCTION MANUAL

Refrigerated air dryers

Synco-GAMMA Application Guide. School building class room. Answers for infrastructure.

PageOne 2-way Pager Assured 2-way messaging for critical communications

Instruction manual. Analyt 2 / Analyt 3

REPEATER FS5200R OPERATION MANUAL

Dohse Aquaristik GmbH & Co. KG. T-Control Pro. Item no Status: 03/2013. Dohse Aquaristik GmbH & Co. KG

Vaccine Storage Safeguarding with the Refrigerator/Freezer Guard

DeltaTherm HC * * Heating controller Manual for the specialised craftsman. Installation Operation Functions and options Troubleshooting

System Installation. multi-zone heating

ProCom The App for Alarm Systems in the Protect Series Operating Manual

GREENSOURCE HYDROLIGHT AND HYDROCOMFORT

ZX1e ZX2e ZX5e. Document No Issue 01 user manual

0701 CO Light, HVAC, Monitoring, Brightness

READ AND SAVE THESE INSTRUCTIONS

1 Opening the IPS WebViewer Activating or Deactivating the Detection Selecting a Profile Text Overlays...

The WAVE Plus Instant Notification System for Schools and Colleges

APPENDIX: APPLICATIONS

B-40/B-41 Modulating Temperature Controller

Technical Manual MDT Motion Detector

ADVISOR CD User Manual. Software from version: V

Clothes Refreshment Machine - CRM. Based on the Nexus 4 dryer structure

Ref. 1067/024 Ref. 1067/032A Ref. 1067/052A

SEC 3500 OI- StatCast RS232 Gas Status Text Broadcast Configuration Manual

Manual# User s Manual. 200E Series. DCU 210E/208E Diesel Engine Control Unit RP 210E Remote Panel

Safewatch Pro 3000 System Manual

FCD-wire Contents. List of Figures

Generator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

3 User s settings. 3.3 Internal clock setting

FirePro control MANUAL

2000 Series. Program Entry Guide. Control Panels

SA 2650 Kit User Manual

Entero Voice Alarm system.

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

HMC300. Control unit. Operating Instructions. EMS plus (2014/10) O

HS-5100, HS-5200, HS-5400 ANALOGUE ADDRESSABLE CONTROL PANELS. User Manual. Approved Document UI-ELAN-02 Revision 03

For the owner and the heating engineer. Operating and Installation Manual VRC 400. Programmable weather compensator with separat HW time control

1.7. Insulation fault evaluators EDS460/490 EDS461/491

Boiler controller S-Tronic Plus

Boiler controller Lambdatronic S 3200

1 DOCUMENT REVISION SOFTWARE VERSION BASIC DESCRIPTION BASIC OVERVIEW OF HYDRAULIC DIAGRAMS HYDRAULIC DIAGRAMS...

BENTEL SECURITY srl reserves the right to modify the technical specifications of this product without prior notice.

NIPPY junior+ Quick Reference Guide

Syncro AS. Analogue Addressable Fire Control Panel. User Manual

HIGH EFFICIENCY FIRETUBE CONDENSING GAS BOILER

&RPPHUFLDO)LUHDQG%XUJODU\ 3DUWLWLRQHG6HFXULW\6\VWHP ZLWK6FKHGXOLQJ

Boiler controller SPS 4000

Dipl.-Ing. W. Bender GmbH & Co. KG Londorfer Str Grünberg Phone: Fax:

Transcription:

Synco living Train the Tainer Functions & Operation Safety & Security Spring 2008 Page 1/32 Train the Trainer - Spring 2008

Settings Absence & supervision Window / door supervision Signaling (buzzer / status output) Fault inputs Fault outputs Displays Page 2/32 Train the Trainer - Spring 2008

Operating button Absence and the monitoring pattern can be set with the central apartment unit s Absence / monitoring button. Page 3/32 Train the Trainer - Spring 2008

Presence & absence When coming or going, the user must press the Absence / monitoring button to make the settings for absence and supervision via the following dialogs. A short press on the button (< 0.4 s) lets the dialog for absence settings appear on the display: Absent Present Absent Present Absence Page 4/32 Train the Trainer - Spring 2008

Absence Absence has the following impact on the plant: Space heating and DHW heating are controlled in accordance with the selected operating mode: Main menu > Heating > Room x > Room operating mode > Optg mode absence > Main menu > Ventilation > Operating mode > Operating mode absence > Main menu > DHW > Operating mode > Optg mode absence > Simulation of presence is started: Main menu > Switching groups > Switching group x > Presence simulation > Switching groups are triggered (event): Main menu > Switching groups > Switching group x >... > Events Switch Dimm Blind Scene Page 5/32 Train the Trainer - Spring 2008

Presence & absence Operating mode Switching groups Presence simulation Page 6/32 Train the Trainer - Spring 2008

Supervision An extended press on the Absence / monitoring button (> 0.4 s) lets the dialog for the supervision settings appear on the display: Inactive Partly monitored All monitored Supervision Inactive Partly monitored All monitored After the setting of absence has been confirmed (present / absent), or after 8 s, the dialog for the supervision settings opens. Note: If supervision is not enabled, the dialog for setting absence also appears after an extended press on the button (> 0.4 s). Page 7/32 Train the Trainer - Spring 2008

Procedure a) Press button briefly b) Confirm absence (ok) or wait 8 s c) Confirm supervision (ok) or wait 8 s Page 8/32 Train the Trainer - Spring 2008

Window / Door Supervision Supervision delay time Main menu > Supervision > Supervision delay > {00.00 59.55} The supervision delay time indicates after what period of time the Window / door supervision function becomes active after Supervision was selected. During the delay time (countdown), monitored windows and doors can still be opened or closed without delivering a fault status message. The supervision delay time appears on the central apartment unit s display: Symbol Countdown (resolution 5 s) Tuesday 13:47 30.03.2007 Absent Partly monitored Page 9/32 Train the Trainer - Spring 2008

Window / Door Supervision Supervision delay time Supervision Überwachung Active Aktiv Inactive Inaktiv Verzögerung Delay On Ein Aus Off Window Fenster Open Offen Closed Zu Türe Door Signaling Signalton Open Offen Closed Zu Ein On Aus Off Continuous tone Bleep A B C D E Time Zeit Page 10/32 Train the Trainer - Spring 2008

Window / Door Supervision Volume of supervision delay signal The volume of the supervision delay signal can be adjusted: Main menu > Supervision > Volume supervision delay > Supervision delay uses 3 types of signals: Continuous tone A monitored window is open during the supervision delay time Bleep (frequency 1 Hz) All monitored windows and doors are closed Bleep (frequency 2 Hz) During the last 15 s of the supervision delay time Note: The volume is independent of the buzzer volume and the volume of the delay time signal. Page 11/32 Train the Trainer - Spring 2008

Window / Door Supervision Supervisory functions Main menu > Supervision > Windows > 2 parameters are used to select the rooms for which the window supervision function is enabled: Partly monitored All monitored All rooms are always listed (12). Release Partly monitored Living room Kitchen Nursery Release All monitored Living room Kitchen Nursery Page 12/32 Train the Trainer - Spring 2008

Window / Door Supervision Supervisory functions Partly monitored: Room C All monitored: Rooms A, B, C Page 13/32 Train the Trainer - Spring 2008

Window / Door Supervision Supervisory functions Main menu > Supervision > Doors > 2 parameters are used to select the doors for which the door supervisory function is enabled: Partly monitored All monitored All doors are always listed (2). Release Partly monitored Entrance door Garage Entrance door Garage Release All monitored Page 14/32 Train the Trainer - Spring 2008

Window / Door Supervision Supervisory functions Partly monitored: Door A All monitored: Doors A & B Page 15/32 Train the Trainer - Spring 2008

Window / Door Supervision Message delay time Main menu > Supervision > Doors > Message delay > {00.00 59.55} The message delay time indicates the period of time on completion of which after the monitored door was opened a fault status message is delivered. The fault status message can be suppressed only when supervision is set to Inactive before the message delay time has elapsed, or when a new value is set. Note: Even if the door is immediately closed again, the central apartment unit delivers a fault status message when the message delay time has elapsed. Page 16/32 Train the Trainer - Spring 2008

Window / Door Supervision Message delay time Überwachung Supervision Delay Meldeverz. Window Fenster Active Aktiv Inactive Inaktiv Ein On Aus Off Offen Open Closed Zu Door Türe Offen Open Closed Zu Alarm active Signaling Signalton Ein On Aus Off A B C D Time Zeit Page 17/32 Train the Trainer - Spring 2008

Window / Door Supervision Volume of message delay signal The volume of the signal tone for the message delay time can be adjusted: Main menu > Supervision > Doors > Volume message delay > Supervision delay uses 2 types of signals: Bleep (frequency 1 Hz) A monitored door was opened Bleep (frequency 2 Hz) During the last 15 s of the message delay time Note: The volume is independent of the buzzer volume and the volume of the delay time signal. Page 18/32 Train the Trainer - Spring 2008

Signalling Buzzer Based on which events shall the buzzer be triggered: Main menu > Supervision > Signaling > Event buzzer > Smoke Window/door supervision Fault input 1 8 Page 19/32 Train the Trainer - Spring 2008

Signaling Buzzer volume The buzzer volume can be adjusted: Main menu > Settings > Device > Buzzer volume > Page 20/32 Train the Trainer - Spring 2008

Signaling Status output Based on which events shall the status output be activated: Main menu > Supervision > Signaling > Event status output > Smoke Window/door supervision Fault input 1 8 Page 21/32 Train the Trainer - Spring 2008

Signaling Signal duration For what period of time shall the buzzer and the status output remain activated: Main menu > Supervision > Signaling > Signal duration > {1 60 min.} Note: On completion of the signal duration, the buzzer / status output will again be deactivated, even if the triggering event is still pending. As soon as one of the buttons on the central apartment unit is pressed, the buzzer / status output will immediately be deactivated, independent of the adjusted signal duration. Page 22/32 Train the Trainer - Spring 2008

Fault Inputs Fault text Main menu > Settings > Faults > Fault input x >... Enter the fault text on the central apartment unit: Oil tank empty. Press Esc to quit the menu and then ok to confirm the entry. Page 23/32 Train the Trainer - Spring 2008

Fault Inputs Fault priority Main menu > Settings > Faults > Fault input x > Fault priority >... Urgent Not urgent It can be selected whether or not the fault status message shall immediately appear on the central apartment unit s display. Urgent Boiler fault Non-urgent Oil tank 1/3 full Page 24/32 Train the Trainer - Spring 2008

Fault Inputs Fault release Main menu > Settings > Faults > Fault input x > Fault release >... Always If absent It can be selected whether the fault status message shall Always be delivered or only when the central apartment unit is set to If absent. Always Boiler fault If absent Garage door open Page 25/32 Train the Trainer - Spring 2008

Fault Inputs Fault status message delay Main menu > Settings > Faults > Fault input x > Fault stat mess dly > {Time} What is the delay time allowed for a pending fault to trigger a fault status message? 30 min Level of aquarium Note: If the fault status message disappears within the delay time, no fault status message will be delivered. Page 26/32 Train the Trainer - Spring 2008

Fault Inputs Normal position Main menu > Settings > Faults > Fault input x > Normal position >... Open Closed It can be selected whether an open or a closed contact shall be identified as a fault. Normal position: Closed Everything ok Page 27/32 Train the Trainer - Spring 2008

Fault Outputs Fault priority Main menu > Settings > Faults > Fault output x > Fault priority >... Urgent Not urgent All Priority, when the fault output shall be activated. Refer to the settings under: Main menu > Settings > Faults > Fault input x > Fault priority >... Urgent Boiler fault All Non-urgent Oil tank 1/3 full Page 28/32 Train the Trainer - Spring 2008

Fault Outputs Origin of fault Main menu > Settings > Faults > Fault output x > Fault source >... Internal Bus Defines whether the fault input shall be activated only with internal or also with external faults (via KNX TP1). KNX TP1 Note: Faults of devices connected to the central apartment unit via KNX RF are also considered to be internal faults. Page 29/32 Train the Trainer - Spring 2008

Display Symbols appearing on the display of the central apartment unit: Present Absent Fault Fault (acknowledgement required) Door open Monitored door open Window open Monitored windows open Windows / doors Partly monitored Windows / doors All monitored Page 30/32 Train the Trainer - Spring 2008

Display Configured inputs and outputs Main menu > Inputs/outputs > Inputs Outputs Inputs Absence Fault input Outputs Fault output 1-2 Status output Door / window state Display 0 = present 1 = absent 0 = no fault 1 = fault Display 0 = no fault 1 = fault 0 = contact open 1 = contact closed 0 = all windows & doors closed 1 = min. one window or one door is open Page 31/32 Train the Trainer - Spring 2008

1. Activate window supervision for room 1. After a change to Absent and after a delay time of 1 minute, the buzzer and the status output shall be activated for 2 minutes if the window is left open. 2. Activate a door supervision. After opening the door (come home) the buzzer shall be activated after 1 minute, without deactivation of the supervision. 3. After closure of fault input 1, an urgent fault status message Low oil level shall appear on the central apartment unit after 10 s and, in addition, the status output shall be activated. 4. Check an open window/door at the info-page. Page 32/32 Train the Trainer - Spring 2008