Corrigo E Ventilation

Similar documents
Manual for the integration in BMS/GTC

Corrigo E - User Manual Ventilation

Corrigo E - manual Ventilation application

Copyright AB Regin, Sweden, Corrigo E manual Ventilation application

Corrigo E. Second generation which contains all applications and languages

SensoPlus ventilation. List of network variables for EXOline, Modbus and BACnet communication. From version 3.6.

MODBUS RS485 TECHNICAL INSTRUCTIONS

Copyright AB Regin, Sweden, Corrigo manual Ventilation application

Sauter flexotron 800 ventilation Manual

WE TAKE BUILDING AUTOMATION PERSONALLY MANUAL CORRIGO

Corrigo E User Guide. Ventilation application

MODBUS RS485. » Technical instructions. Air Comfort. Housing ventilation

SAUTER flexotron800 V2 Ventilation V3.3. manual P P

Corrigo E - User Manual Heating

MicroTech Series 200 Centrifugal Chiller

Pre-programmed room controller with communication

SAUTER flexotron800 V2 Ventilation List of network variables for Modbus- and BACnet communication User manual

Modbus protocol REGO I

SAUTER flexotron 800 Ventilation application User Guide

Pre-programmed room controller with communication

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

Pre-programmed room controller with communication and hidden setpoint

Modbus TCP/IP Option Instruction Manual

DTSX200 Communications(Modbus) Guide

Database for CTS6000 MODBUS

FlameGard 5 UV/IR HART

FL500 Modbus Communication Operating Manual. Order No.: /00. MSAsafety.com

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Installation Manual Tracker 221

Modbus RTU RS485 Manual

Modbus TCP Register List GreenManager for GreenMaster C-F Valid for firmware version 2.0 or later

MicroTech Rooftop/RMC

The RCF range. Controllers and thermostats for fan-coil units

MicroTech Unit Ventilator

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

Installer Manual KNX Touchscreen Thermostat

Sales and Engineering Data Sheet ED

MicroTech Series-200 Flooded Screw Chiller

C-series Controllers for air handling systems

Q-SMART MODBUS KIT. Modbus Protocol & Parameters. Cod EN rev.a ed.08/2018. Q-SMART Software Version AE17

EOS INTERFACE GUIDE AND POINTS LIST For EOS BTCII Firmware Version J1239D-570 and newer

EXcon zone control. Control for up to 4 individual zones _ fm. EXHAUSTO A/S Odensevej 76 DK-5550 Langeskov

READ AND SAVE THESE INSTRUCTIONS

Air Handling Unit. REC Temovex Blue 4 NEW! Experts on indoor climate in low-energy houses

Corrigo ventilation. List of network variables for EXOline, Modbus and BACnet communication. From software version 3.4

PRODUCT DATA COMFORT 450 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 450 m 3 /h

N M AirControl AHU. Control manual

Corrigo E User Guide. Heating application

ibox Modbus Server Gateway for the integration of Notifier ID3000 / ID3002 / ID60 / ID50 fire panels in Modbus enabled monitoring and control systems

Installation Instructions for the TBLZ-2-66 control box. for controlling two air handling units (Twin Function) GOLD RX

General Specifications

Alarm Manager Plug-in

Netbiter Tank Sensor

SM3000 Videographic Recorder. User Guide. Modbus (RTU) Communications Option

Installation Guide Bacharach Communications Adapter HGM-MZ to Johnson Controls Metasys N2 Network (Electrically Isolated N2 Port Version)

Series Digital Controller Instruction Sheet

PRODUCT DATA COMFORT 600 BY NILAN. Ventilation & passive heat recovery. Passive heat recovery. < 800 m 3 /h

Process & TeMPerATUre UniversAl input DigiTAl MeTers

Corrigo E - User Manual Heating

RS485 MODBUS Module 8AI

ModBus DE-1 INSTALLATION AND USER MANUAL

DC VOLTMETER DCV-10 / 10A / 10C / 10S / 10CS / 11 / 11A / 11C / 11S / 11CS. A4741 / Rev.1

Topvex SF02-SF12 Air Handling Unit

Metasys Integrator TITUS Application

ECL Comfort 110, application 116

DPR-145 TEMPERATURE PROTECTION RELAY. DPR-145 User Manual V-2.0 ( ) PT100 INPUTS: 4 RELAY OUTPUTS: 4 RS-485 MODBUS PORT VDC SUPPLY -1-

PROCESS & TEMPERATURE UNIVERSAL INPUT DIGITAL METERS

Brivis Touch Controller. Installer Manual

Systemair UAB Linų st. 101, LT Ukmergė, LITHUANIA Phone: Fax:

Silencer Preheater unit Electric post-heating unit Water circulated post-heating unit CO 2 sensor %RH sensor Pressure difference switch LON converter

TSI Model 8630 PRESSURA Room Pressure Monitor Modbus Communications Application Note LC-106

P2267 NETWORK INTERFACE

Compod. Instruction Manual IM-COMPOD Revision: F, December 2015

SmartDial. Wireless. User Manual. -en_gb language A004. Document in original

FlameGard 5 MSIR HART

Sales and Engineering Data Sheet ED

ABOUT THIS DOCUMENT AND THE DOCUMENT STRUCTURE WE USE

Topvex SR 09, 11, Topvex TR Compact Air Handling Units

Modular Standard HP Chiller 1/4 screw compressor with Carel driver

NGC-40 Bridge. Modbus Overview. Raychem-AR-H58862-NGC40BridgeModbusOV-EN-1805 nvent.com 1

Application description

Mounting and Operating Instructions EB 5610 EN. TROVIS 5600 Automation System TROVIS 5610 Heating and District Heating Controller

Heating and D.h.w. Controller RVL482 Basic Documentation

FieldServer Driver - Serial FS McQuay Microtech Open Protocol

Weather compensated flow temperature control of heating and boiler systems

C5 controller Bacnet

Topvex SX/C, Topvex TX/C Air Handling Unit

User Guide

Products no longer available

VTI MODEL itc5000 HEAT TRACING CONTROL SYSTEM OPERATIONS MANUAL

C66. ECL Comfort. User's Guide. Installer's Guide. ECL Comfort C66. User's Guide. Installer's Guide. *vi7cc502* *087R8069* *087R8069* *vi7cc502*

Installation Guide. ECL Comfort 210, application A Table of Contents

Series Temperature Controller Instruction Sheet

725B Configuration Software Manual

Automation System TROVIS 5400 Ventilation Controller TROVIS Mounting and Operating Instructions EB 5477 EN. Electronics from SAMSON

Figure 1. Proper Method of Holding the ToolStick. Figure 2. Improper Method of Holding the ToolStick

Centaur TM II Cube Slave Alarm Signalling Equipment INSTALLATION GUIDE

FCD-wire Contents. List of Figures

Manual# User s Manual. 200 Series. DCU 210/208 Diesel Engine Control Unit RP 210 Remote Panel

PRODUCT DATA COMBI 300 POLAR BY NILAN. Ventilation with passive & active heat recovery. Active heat recovery. Passive heat recovery.

Transcription:

Corrigo E Ventilation Modbus communication guide Contains the most commonly used variables. Covers all versions of Corrigo E Ventilation from 3.2 The challenger in building automation Revision: 2 Date: October 03 2013 Copyright AB REGIN, Sweden, 2013

DISCLAIMER The information in this manual has been carefully checked and is believed to be correct. Regin however, makes no warranties as regards the contents of this manual and users are requested to report errors, discrepancies or ambiguities to Regin, so that corrections may be made in future editions. The information in this document is subject to change without prior notification. The software described in this document is supplied under licence by Regin and may be used or copied only in accordance with the terms of the licence. No part of this document may be reproduced or transmitted in any form, in any fashion, electronically or mechanically, without the express, written permission of Regin. COPYRIGHT AB Regin. All rights reserved. TRADEMARKS Corrigo E, E tool, EXOdesigner, EXOreal, EXOline, EXO4, EXO4 Web Server, Optigo, Regio and Regio tool are registered trademarks of AB Regin. Windows, Windows 2000, Windows XP, Windows 7, Windows 8 and Windows Server 2003 are registered trademarks of Microsoft Corporation. Some product names mentioned in this document are used for identification purposes only and may be the registered trademarks of their respective companies. Revision C, September 2013 Software revision: 3.2

Table of contents CHAPTER 1 INTRODUCTION... 4 CHAPTER 2 MODBUS COMMUNICATION... 5 CHAPTER 3 MODBUS AND CORRIGO E... 8 CHAPTER 4 SETTING UP MODBUS COMMUNICATION... 9 CHAPTER 5 COMMONLY USED SIGNALS... 11 5.1 Input Status... 11 5.2 Holding Register Setpoint settings... 11 5.3 Holding Register Manual / Auto settings... 12 5.4 Input Registers... 14 APPENDIX ALARM LIST... 16

Chapter 1 Introduction Corrigo E ventilation Corrigo E ventilation is a pre-programmed application for control of an air handling unit. The Corrigo E controller can either be used stand-alone or integrated in an existing EXO project, in both cases it is configured via the display or using the configuration tool E tool on a PC. About this manual This document provides an introduction to communication via Modbus and contains a list of commonly used signals. This list is found in chapter 5. A complete list of all signals accessible via Modbus and the EXOline protocol is found in the document Corrigo E Ventilation variables (accessible via the help menu in E tool). This document does not describe how to create an EXO project or how to set up EXOline communication. For these matters, please refer to the EXO System and E tool manuals. Signals All signals described in this document are accessible from a SCADA/Modbus master system. The signals that have a default value are settings that can be changed; the signals without default values are actual values and cannot be changed. 4 Introduction Modbus communication guide

Chapter 2 Modbus communication General A Modbus network consists of one master unit and one or more slave units. The Master controls the communication and requests information from the slave units. These are bound to answer in a certain manner depending on the request. The rules for communication are set up by the protocol. The Modbus protocol specification can be downloaded for free from the Modbus Organisation website www.modbus.com. The simplified example below visualises the Master/Slave relation. In addition to the figure, checksums for message validation are also transmitted in both query and answer. EXOL type The Corrigo is programmed in the language EXOL, which has four different types of signals. These signal types are important to keep in mind since they decide what scale factor should be used to interpret the signal values. More about scale factors in chapter 3. The EXOL types of the signals: R = Real (-3.3E38-3.3E38) I = Integer (-32768-32767) X = Index (0-255) L = Logic (0/1) Modbus communication guide Modbus communication 5

Modbus type The Modbus types are not bound to the EXOL types. Therefore the list of common signals in chapter 5 contains both types. The Modbus types of the signals (type in the list in chapter 5): 1 = Coil Status Register (Modbus function = 1, 5 and 15) 2 = Input Status Register (Modbus function = 2) 3 = Holding Register (Modbus function = 3, 6 and 16) 4 = Input Register (Modbus function = 4) 2 and 4 are read-only, while 1 and 3 are read-write. Modbus functions The Modbus master uses different Modbus functions in its query, depending on whether to read or write values. A function also describes what signal type it is meant for. Supported Modbus functions: 1 = Read Coils 2 = Read Discrete Input 3 = Read Holding Register 4 = Read Input Register 5 = Write Single Coil 6 = Write Single Register 15 = Write Multiple Coils 16 = Write Multiple Registers Max. 47 registers Max. 47 registers can be read in one message. Modbus wiring etc. A protocol such as Modbus consists of several layers (OSI-model). The bottom layer is always the physical layer, number of wires and signal levels. The next layer describes the communication digits (number of data bits, stop-bits, parity etc.). After that come the layers describing the Modbus specific functions (number of digits per message, the meaning of different messages etc.). For Modbus, the bottom layer can be RS485, RS422 or RS232. RS485 contra RS422 RS485 and RS422 are the electric part of the protocol, i.e. the physical layer. RS485 has two connections, A and B. Often there is also a protective ground (N on EXO controllers). RS485 units are always connected A A and B B. RS485 is so-called half duplex communication: Communication can only go in one direction at a time; i.e. the master will first send an enquiry and will thereafter listen for the reply. A and B are used for both transmission and reception. RS422 is a full duplex communication which means that you need 4 wires, 2 for transmission (Tx+ and Tx-) and 2 for reception (Rx+ and Rx-). Tx is used to transmit and Rx to receive which means that Tx in one unit must be connected to Rx in the other and vice versa. As for signal levels etc., RS422 and RS485 are identical. 6 Modbus communication Modbus communication guide

To interconnect RS485 and RS422, connect Tx+ with Rx+ and Tx- with Rx- on the RS422 unit. We have now changed a 4-wire system to a 2-wire system and can connect them to A and B on the RS485 unit. Which goes where is something you usually find out by trial and error. Incorrect polarity will just give non-function but cannot harm the units. Tx+ ----- ---------------------------------------- A (or B) Rx+ ------ Tx- ----- ---------------------------------------- B (or A) Rx- ------ Bitrate, two stop bits, parity is the next layer These settings must correspond to the settings in the master unit. Find out how the master is set and then give the Corrigo E the same settings. Parity can be set to odd, even or none. You can only choose one stop-bit. 1 start-bit, 8 data-bits, 1 parity-bit and 1 stop-bit give a total of 11 bits which is the maximum. Modbus communication guide Modbus communication 7

Chapter 3 Modbus and Corrigo E Communication limits The Modbus master must wait for a minimum of 3.5 charactertimes (4 ms at 9600 bps) between two messages. When the Modbus master communicates with more than one Corrigo E controller on the same communication line (RS485), the Modbus master must wait for a minimum of 14 charactertimes (16 ms at 9600 bps) between the answer and the first question for the next controller. Scale factor Modbus Real signals have scale factor 10 except the time settings signals that have scale factor 100 and air flow signals that have scale factor 1 for Modbus communication. Integer, Index and Logic always have scale factor 1. Modbus activation Corrigo E uses the same port for both Modbus communication and EXOline communication. If you try to communicate with a Modbus-activated unit using E tool or other EXOline communication, the input port will automatically adapt itself after approx. 1 s. The port will remain in EXO mode until 10 seconds of communication inactivity have passed, after which it will revert to Modbus mode. 8 Modbus and Corrigo E Modbus communication guide

Chapter 4 Setting up Modbus communication Configuration The first important thing to configure is the communication parameters for the Modbus line. As described earlier, these parameters must be identical in the master unit and the slave units, since they define the structure of messages and the transmission speed. The default configuration values of a Corrigo E controller are shown in the figure below. Corrigo E is by default set to Slave Address 1. If more units are added, a new Modbus address can be set for each unit using the Corrigo E display or E tool. Transmission mode Corrigo E uses the RTU transmission mode, not to be mixed up with the ASCII mode in the settings. The settings for the transmission mode must be the same in the master unit and the slave units, since Modbus/RTU cannot understand Modbus/ASCII messages. The configuration parameter Word length is always 8 for Modbus/RTU. Writing values To override the Corrigo E output values, set the output to manual mode using a Modbus signal. Then set the corresponding..._manset signal to the wanted level. These signals are listed in Holding Registers. In this document, all signals that are not listed in Holding Registers are read-only. Modbus communication guide Setting up Modbus communication 9

Reading values An effective way to read values is to read multiple variables simultaneously. For example, to read the heating, exchanger and cooling levels, set the Modbus query to the values shown in the figure below. The heat output variable starts at address 119 (VentActual.Cor_HeatCV1(0)). To read address 119 to 121, set the length to 3. Then the Modbus answer will communicate all 3 values in just one message, making the communication more effective. 10 Setting up Modbus communication Modbus communication guide

Chapter 5 Commonly used signals To simplify system integration, a register of commonly used signals is provided below. Please refer to the document Corrigo Ventilation variables for a complete list. 5.1 Input Status Address Variable name EXOL type Values Description 1x0008 1x0009 1x0033 1x0080 1x0090 1x0130 1x0284 VentActual.Cor_Extended RunActiveFull VentActual.Cor_Extended RunActiveHalf VentActual.Cor_AlaPt(1) VentActual.Cor_AlaPt(48) VentActual.Cor_AlaPt(49)... VentActual.Cor_AlaPt(89) VentActual.Cor_UnitRun Mode Logic 0/1 Set if extended operation full speed Logic 0/1 Set if extended operation half speed Logic 0/1 (1=Alarm) Logic 0/1 (1=Alarm) Alarm points (see the Appendix) 1x0033 = Alarm point 1 1x0080 = Alarm point 48 Alarm points (see the Appendix) 1x0090 = Alarm point 49 1x0130 = Alarm point 89 Index 0/1/2/3 Unit run mode: 0=Off 1=Reduced speed 2=Normal speed 3=Stop because of alarm 5.2 Holding Register Setpoint settings Values for holding registers are adjustable (read/write). Address Variable name EXOL type Default value Description 4x0001 4x0018 4x0019 4x0024 VentSettings.Cor_SupplyS etpoint VentSettings.Cor_Exhaust Setpoint VentSettings.Cor_RoomSe tp VentSettings.Cor_SAFFull speedpressure Real 18 C Setpoint supply air temperature when constant supply air temperature function Real 21 C Setpoint extract air temp. if extract air temp. control function Real 21 C Room setpoint if room temp. control function Real 500 Pa Setpoint full speed supply air fan pressure Modbus communication guide Commonly used signals 11

Address Variable name EXOL type Default value Description 4x0025 4x0026 4x0027 4x0028 4x0029 4x0030 4x0031 4x0392 4x0404 4x0405 4x0465 4x0466 4x0467 VentSettings.Cor_SAFHalf speedpressure VentSettings.Cor_EAFFull speedpressure VentSettings.Cor_EAFHalf speedpressure VentSettings.Cor_SAFFull speedairflow VentSettings.Cor_SAFHalf speedairflow VentSettings.Cor_EAFFull speedairflow VentSettings.Cor_EAFHalf speedairflow VentActual.Cor_OutDoorT emp(0) VentSettings.Cor_SupplyS etpointmax VentSettings.Cor_SupplyS etpointmin VentSettings.Cor_Demand CO2Value1 VentSettings.Cor_Demand CO2Value2 VentSettings.Cor_Demand CO2Diff Real 250 Pa Setpoint reduced speed supply air fan pressure Real 500 Pa Setpoint full speed extract air fan pressure Real 250 Pa Setpoint reduced speed extract air fan pressure Real 2000 m 3 /h Setpoint full speed supply air fan flow. Scale factor = 1 Real 1000 m 3 /h Setpoint reduced speed supply air fan flow. Scale factor = 1 Real 2000 m 3 /h Setpoint full speed extract air fan flow. Scale factor = 1 Real 1000 m 3 /h Setpoint reduced speed extract air fan flow. Scale factor = 1 Real Outdoor temperature (Can be modified if not connected to a physic analogue input). Real 30 C Max. limit of supply setpoint when cascade control Real 12 C Min. limit of supply setpoint when cascade control Real 800 ppm Activating of demand controlled ventilation 1/2- speed Real 1000 ppm Activating of demand controlled ventilation 1/1- speed Real 160 ppm Hysteresis for stop of demand controlled ventilation (ppm) 5.3 Holding Register Manual / Auto settings Address Variable name EXOL type Default value Description 4x0368 4x0369 4x0370 VentSettings.Cor_AirUnit AutoMode VentSettings.Cor_SupplyP ID_Select VentSettings.Cor_SupplyP ID_ManSet Index 3 Running mode air unit: 0=Manual off 1=Manual reduced speed 2=Manual normal speed 3=Auto Index 2 Supply temp. controller mode: 0=Manual off 1=Manual on 2=Auto Real 0 % Supply temp. controller output if manual on mode 12 Commonly used signals Modbus communication guide

Address Variable name EXOL type Default value Description 4x0371 4x0372 4x0373 4x0374 4x0375 4x0376 4x0377 4x0378 4x0379 4x0380 4x0381 4x0382 4x0383 4x0384 VentSettings.Cor_SAFAut omode(0) VentSettings.Cor_EAFAut omode VentSettings.Cor_SAFFreq uenceautomode VentSettings.Cor_SAFMan ual VentSettings.Cor_EAFFre quenceautomode VentSettings.Cor_EAFMa nual VentSettings.Cor_HeatCoil AutoMode(0) VentSettings.Cor_HeatCoil Manual(0) VentSettings.Cor_ExchCoi lautomode VentSettings.Cor_ExchCoi lmanual VentSettings.Cor_CoolCoil AutoMode VentSettings.Cor_CoolCoil Manual VentSettings.Cor_Humidit ypid_select VentSettings.Cor_Humidit ypid_manset Index 3 Running mode SAF: 0=Off 1=Manual half speed 2=Manual full speed 3=Auto Index 3 Running mode EAF: 0=Off 1=Manual half speed 2=Manual full speed 3=Auto Index 3 Running mode frequency controlled SAF 0=Manual 1=Man. half speed 2=Man. Fullspeed 3=Auto Real 0 % Frequency controller output SAF if manual mode Index 3 Running mode frequency controlled EAF 0=Manual 1=Man. half speed 2=Man. full speed 3=Auto Real 0 % Frequency controller output EAF if manual mode Index 2 Running mode Heating: 0=Off 1=Manual 2=Auto Real 0 % Heating controller output if manual mode Index 2 Running mode Exchanger: 0=Off 1=Manual 2=Auto Real 0 % Exchanger controller output if manual mode Index 2 Running mode Cooling: 0=Off 1=Manual 2=Auto Real 0 % Cooling controller output if manual mode Index 2 Running mode Humidification/Dehumidific ation: 0=Off 1=Manual 2=Auto Real 0 % Humidification/Dehumidific ation controller output if manual mode Modbus communication guide Commonly used signals 13

Address Variable name EXOL type Default value Description 4x0385 4x0386 4x0387 4x0388 4x0451 VentSettings.Cor_HeatPu mpautomode(0) VentSettings.Cor_ExchPu mpautomode VentSettings.Cor_CoolPu mpautomode VentSettings.Cor_FireDam perautomode VentSettings.Cor_External Control Index 2 Running mode P1-Heating: 0=Manual off 1=Manual on 2=Auto Index 2 Running mode P1- Exchanger: 0=Manual off 1=Manual on 2=Auto Index 2 Running mode P1-Cooling: 0=Manual off 1=Manual on 2=Auto Index 2 Running mode fire damper: 0=Close 1=Open 2=Auto Index 2 External control: 0=Extended run full speed 1=External stop 2=No external control 3=External stop with support control 5.4 Input Registers Values for input registers are read-only. Address Variable name EXOL type Description 3x0001 VentActual.Cor_OutDoorTem Real Outdoor temperature p(0) 3x0002 VentActual.Cor_Efficiency Real Efficiency in % for exchanger 3x0003 VentActual.Cor_RunMode Index 0=Stopped 1=Starting up 2=Starting reduced speed 3=Starting full speed 4=Starting normal run 5=Normal run 6=Support control heating 7=Support control cooling 8=CO 2 run 9=Night cooling 10=Full speed stop 11=Stopping fan 3x0007 VentActual.Cor_SupplyAirTe Real Supply air temperature mp 3x0009 VentActual.Cor_ExhaustAirTe Real Extract air temp mp 3x0010 VentActual.Cor_RoomTemp1 Real Room temperature 1 3x0011 VentActual.Cor_RoomTemp2 Real Room temperature 2 3x0013 VentActual.Cor_SAFPressure Real Supply air fan pressure (Pa) 14 Commonly used signals Modbus communication guide

Address Variable name EXOL type Description 3x0014 VentActual.Cor_EAFPressure Real Extract air fan pressure (Pa) 3x0015 VentActual.Cor_SAFAirFlow Real Supply air fan flow (m3/h). Scale factor = 1. 3x0016 VentActual.Cor_EAFAirFlow Real Extract air fan flow (m3/h). Scale factor = 1. 3x0017 VentActual.Cor_CO2Sensor Real CO 2 (ppm) 3x0019 VentActual.Cor_Frostprotectio Real Frost protection temp ntemp 3x0021 VentActual.Cor_DeIcingTemp Real De-icing temp exchanger 3x0023 VentActual.Cor_HumidityRoo Real Humidity room m 3x0025 VentActual.Cor_ExtraSensor Real Additional sensor / External setpoint 3x0119 VentActual.Cor_HeatCV1(0) Real Control signal heating Y1 (0 10 V) 3x0120 VentActual.Cor_ExchCV1 Real Control signal exchanger Y2 (0 10 V) 3x0121 VentActual.Cor_CoolCV1 Real Control signal cooler Y3 (0 10 V) 3x0122 VentActual.Cor_SAF Real Control signal supply air fan (0 10 V) 3x0123 VentActual.Cor_EAF Real Control signal extract air fan (0 10 V) Modbus communication guide Commonly used signals 15

Appendix Alarm list No. Alarm text Prio Description 1 Run Error Supply Air Fan B Malfunction Supply air fan 2 Run Error Extract Air Fan B Malfunction Extract air fan 3 Run Error P1-Heater B Malfunction pump, Heating circuit 4 Run Error P1-Cooler B Malfunction pump, Cooling circuit 5 Run Error P1-Exchanger B Malfunction pump, Liquid connected exchanger 6 Filter guard B Filter guard pressure switch activated 7 Flow guard B Flow guard activated 8 External frost guard A External Frost protection thermostat activated 9 Deicing pressure guard - Exchanger de-icing pressure switch activated 10 Fire alarm A Fire alarm activated 11 External switch C External switch activated 12 External alarm B External alarm activated 13 Supply Air control error B Supply air temp deviates too much from the setpoint for too long 14 Humidity control error - The room humidity deviates too much from the setpoint. 15 High supply air temp B Supply air temp too high 16 Low supply air temp B Supply air temp too low 17 Supply air temp max - Maximum limiting of supply air temp active 18 Supply air temp min - Minimum limiting of supply air temp active 19 High room temp B Room temp too high during room temp control 20 Low room temp B Room temp too low during room temp control 21 High extract air temp B High extract air temp during extract air control 22 Low extract air temp B Low extract air temp during extract air control 23 Electric heating is overheated A Heater high temperature limit switch activated 24 Frost risk B Frost protection function is overriding the control of the heater output 25 Low frostguard temp A Frost protection temperature below frost limit value 26 Low efficiency B Heat exchanger efficiency below limit value 27 Sensor error Outdoor temp B Malfunction of connected sensor 28 Analogue deicing - Exchanger de-icing activated by de-icing sensor 29 Rotation guard exchanger B Exchanger rotation sentinel alarm activated 30 Fire damper is out of operation B Fire damper exercise test failed 31 Supply Air Fan control error - Supply air pressure deviates too much from the setpoint for too long. 32 Extract Air Fan control error - Extract air pressure deviates too much from the setpoint for too long. 33 Supply Air Fan external operation C SAF run-signal received when unit is stopped 34 Extract Air Fan external operation C EAF run-signal received when unit is stopped 35 Ventilation Manual mode C The unit is shut down 36 Manual supply air control C Supply air temp controller in manual control 16 Appendix Alarm list Modbus communication guide

No. Alarm text Prio Description 37 Manual supply Air Fan mode C Supply air fan in manual control 38 Freq. SAF Manual C Signal to SAF frequency converter in manual control 39 Manual Extract Air Fan mode C Extract air fan in manual control 40 Freq. EAF Manual C Signal to SAF frequency converter in manual control 41 Heating Manual Manual C Heating output in manual control 42 Manual exchanger control C Heat exchanger output in manual control 43 Manual cooler control C Cooling output in manual control 44 Manual P1-Heater C Heating circulation pump in manual control 45 Manual P1-Exchanger C Exchanger circulation pump in manual control 46 Manual P1-Cooler C Cooling circulation pump in manual control 47 Fire damp. Manual C Fire dampers in manual control 48 Internal battery error A Internal battery needs replacing 49 Sensor error Supply Air temp B Malfunction of connected sensor 50 Sensor error Extract Air temp B Malfunction of connected sensor 51 Sensor error Room temp 1 B Malfunction of connected sensor 52 Sensor error Room temp 2 B Malfunction of connected sensor 53 Sensor error Exhaust air temp B Malfunction of connected sensor 54 Sensor error Extra sensor B Malfunction of connected sensor 55 Sensor error SAF pressure B Malfunction of connected sensor 56 Sensor error EAF pressure B Malfunction of connected sensor 57 Sensor error Deicing temp B Malfunction of connected sensor 58 Sensor error Frost Protection temp B Malfunction of connected sensor 59 Sensor error CO2 B Malfunction of connected sensor 60 Sensor error Humidity Room B Malfunction of connected sensor 61 Sensor error Humidity Duct B Malfunction of connected sensor 62 Sensor error Extra unit temp B Malfunction of connected sensor 63 Sensor error External control SAF B Malfunction of connected sensor 64 Sensor error External control EAF B Malfunction of connected sensor 65 Sensor error SAF Pressure 2 B Malfunction of connected sensor 66 Sensor error Humidity outdoor B Malfunction of connected sensor 77 Alarm Frequency converter SAF A Malfunction of frequency converter SAF 78 Alarm Frequency converter EAF A Malfunction of frequency converter EAF 79 Communication error Frequency SAF C Communication problem with Vacon NXL 80 Communication error Frequency EAF C Communication problem with Vacon NXL 81 Communication error Expansion unit 1 C Communication problem with a controller connected to port 2 82 Communication error Expansion unit 2 C Communication problem with a controller connected to port 2 83 Warning Frequency converter SAF C 84 Warning Frequency converter EAF C 85 Output in manual mode C Analogue or digital output in manual mode 86 Time for service C Time for service 87 Manual Y4-Extra Sequence control C Y4-Extra sequence in manual control 88 Restart blocked after power failure C Restart blocked after power failure 89 Manual Y5-Extra Sequence control C Y5-Extra sequence in manual control Modbus communication guide Appendix Alarm list 17

R E G I N T H E C H A L L E N G E R I N B U I L D I N G A U T O M A T I O N AB Regin Head office Box 116, S-428 22 Kållered, Sweden Phone: +46 31 720 02 00 Fax: +46 31 720 02 50 info@regin.se www.regin.se