Power Protection Solutions

Similar documents
elite Model ELN Centralized Emergency Lighting Inverter Systems 550 W to 1.5 KW Systems

Model LTN-3R Outdoor Rated Uninterruptible Power System Single Phase

UltraLITE Model ELU Centralized Emergency Lighting Inverter 4.2 KW- 5 KW

SECTION POWER SUPPLIES AND DISTRIBUTION

ILLUMINATOR EM. CENTRAL LIGHTING INVERTER 1000 VA/W through 2800 VA/W 98% Efficiency!

Spectron LSN (Life Safety Network) Suggested Specifications

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

LORAIN CSP DC Power System

ILLUMINATOR E & IE CENTRAL INVERTER FOR EMERGENCY LIGHTING

LORAIN CIP 4890/48120 DC Power System

Liebert PPC Second Generation Power Distribution Cabinet

UltraLITE MODEL ELU. Centralized Emergency Lighting Inverters

elite TM SERIES Centralized Emergency Lighting Inverters MODEL ELE

LiteMinder. LM Series Inverter Pure Sine Wave Modular Inverter Technology. Fast Transfer System 1.0 to 18.75KVA LED Compatible

UltraLITE. Centralized Emergency Lighting Inverters MODEL ELU

Central Emergency Lighting Inverter Systems

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

Soft Start Series MP700 Solid State, Reduced Voltage

wireless. web-based. worthy of the name RACO.

1.1 RELATED DOCUMENTS: 1.2 DESCRIPTION OF WORK: 1.3 QUALITY ASSURANCE: 1.4 Warranty SECTION BATTERY EMERGENCY POWER SUPPLY PART 1 - GENERAL

Light Support Power Systems CENTRAL EMERGENCY LIGHTING INVERTER SYSTEMS

Galaxy Pulsar Plus Digital Battery Plant Controller

AC300WR 300 WATT REDUNDANT HF-20A CHASSIS POWER SUPPLY/SYSTEM MONITOR TECHNICAL MANUAL

DGC-1000 DIGITAL GENSET CONTROLLER

Bulletin 1608N MiniDySC Dynamic Sag Corrector

Across-the-Line SERIES MP300 Combined Manual and Automatic

SP40S-D. Kingfisher Company, inc. Features: Description:

Based on years of Industry experience it s ready to run right out of the box, simply assign the IP address and connect to the embedded web server.

HP Power Distribution Unit with Power Monitoring (Models S124 and S132) User Guide

DGC-500 DIGITAL GENSET CONTROLLER

R E C T I F I E R I N V E R T E R C O N V E R T E R SB7

X11CA COMPUTER ANNUNCIATORS

Variable Frequency Drive SERIES MP800 VFD

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

NetSOLO Broadband. Voice Evacuation. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

DIESEL Engine Fire Pump Controllers Features

and 4 alarm extensions provide system conditions. The controller can be accessed through the front panel craft port or optional modem connectivity.

RACK MONITORING SYSTEM RAMOS Ultra

E3 Series Broadband System

EON TM. 10 kw - 55 kw THREE PHASE. Centralized Emergency Lighting Inverters MODEL EL3

Integrated Process Solutions. Series 48 Heaters. heater jackets sizes 1 1/2'' to 4'' (nw 40 to nw 100)

RACK MONITORING SYSTEM - RAMOS Ultra

Liquid Helium Level Instruments

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

OPR Power Series AC to DC POWER SUPPLY SERIES WITH REMOTE MANAGEMENT AND ALARM SYSTEMS. Model Nos. OPR200-24S / OPR200-24R. Manual

Model A1700 Series Annunciator

» EN50171» Lighting» Reliable

I/A Series 716C 1/16 DIN Temperature Controller

EC-BOS-602/616 AX Security

APC BC300 Series 40kW 208/450/480V User Guide

Mounting Kits. LWMB2 6" 6 3 /8" 5 7 /8" 2.6 lbs lbs. LCMB2 6" 5" 5 3 /4 2.3 lbs. 2.5 lbs.

Monitoring Solutions

CHEETAH XI INTELLIGENT SUPPRESSION CONTROL SYSTEM

Combined CAN Sensor Unit Temperature, Humidity and Smoke

Revision: None DCN No. First Issue Date: November 30, 1998 Product: Standard DCT, 120-volts

Remote / Network Control for Rack Cabinet Access - DL Series

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

AirFlow Sensor for Dry Contact connection

ECC-50/100(E) Emergency Command Center. General. Features. Emergency Voice Evacuation TYPICAL APPLICATIONS

PowerWave 2 Busway System

Model A2100 Series Annunciator

Float Battery Chargers Unfiltered SCR and Filtered SCRF Series Single Phase Input / Three Phase Input

AS950 PORTABLE SAMPLERS

ECC-50/100C. Emergency Command Center

E3 Series Broadband. Description. Features. Intelligent, Networked, Multi-Channel Fire Alarm Control and Emergency Voice Evacuation System

MAX ARM. Heavy Duty Linear Actuator for Residential / Commercial use. Super quiet Solar ready Large diameter stainless steel output shaft

Centro-Matic Automated Lubrication Systems System Controls

Autonomous control unit

VEROTEC Electronics Packaging

Flexible & Innovative. Cooling Solutions

Model 1062 Environment Monitor

ESP TECHNOLOGIES LIMITED

NORTHWESTERN UNIVERSITY PROJECT NAME JOB # ISSUED: 03/29/2017

CX/CXB Self-Managed Ethernet Switches N-664 Network Appliance Data and Alarm I/O Device MX Series Multi-Port Switches

Utility Battery Chargers DC Power Systems Custom Design

E3 Series Broadband System

GMS GRAPHICAL MANAGEMENT SYSTEM

Rack Mount Series Installation Guide

>>> Rack Environmental Management

SIMATRIX NEO Modular Video Matrix

AS950 REFRIGERATED SAMPLERS

SAFEPATH Mass Notification System (SPMNS)

The system is expanded via the RCC network with each RCC capable of passing information to and from up to 31 detection or output devices.

NU2 Smart Power Supply (SPS) Manual

ECC-50/100(E) Emergency Command Center

SCR/SCRF SERIES. Industry s First Choice for Time-Tested Proven Reliability FLOAT BATTERY CHARGERS. Single-Phase Input

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

AL400ULACM AL600ULACM - 4 amp - 12VDC or 6 amp. - Fused Outputs - Fused Outputs

KWX N4 PDU. Intelligent, Rack Mounted, Power Distribution Units. The most innovative PDU on the market KWX-N16A10C3-H4F MONITORED & SWITCHABLE PDU

HIGH BAY APPLICATIONS

NGC-40 PANEL MOUNTED ADVANCED MODULAR HEAT-TRACING CONTROL SYSTEM HTC HTC3

Typical applications include the vibration detector. Detection of vibrations and shocks

Guide Specification Model CTG Automatic Transfer Switch

Addressable Fire Alarm Control Panel

GENERAL STANDARD FEATURES. ISO-9001 Engineering and Manufacturing Quality System Certified to International Standard ISO-9001 PATENT PENDING

SECTION CENTRAL BATTERY INVERTERS. A. This Section includes fast-transfer central battery inverters with the following features:

DIESEL Engine Fire Pump Controllers Features. FD120 Diesel Engine Controllers

For a red enclosure add an R suffix to the part # e.g. eflow4na8dr. Altronix Corp th St. Brooklyn, NY. Installing Company: Service Rep.

CALTECH Pasadena, CA

MiNi Server environment MoNitoriNg SySteM

Transcription:

Power Protection Solutions

CONTENTS TRAFFIC PRODUCTS 4 SP 1250LE SP 1250LX SP 2000LX SP Series PD SP 170 PDA 5 6 7 8 9 ITS / SECURITY / PUBLIC SAFETY MILITARY PRODUCTS 10 SP 560 SP 1250DLE DT Series CMN Series CT Series GT Series 11 12 13 14 15 16 ACCESSORIES / COMMUNICATIONS 17 Outpost Batteries Bypass Switches SNMP/HTTP Adapter Remote View Software Enclosures 18 19 19 19 20 1

A BRIEF HISTORY In 1939, Clary Corporation started out as a high tech manufacturer of precision aircraft parts for the military. Over the next 30 years, Clary evolved into manufacturing unique technology including gyroscopic devices for military missile programs, portable computer products and mechanical adding machines. Clary s experience in computer manufacturing challenged the company to evolve once again. In the early 1970 s, Clary designed the industry s first all solid state Uninterruptible Power Supply (UPS). In 1997, Clary refined their solid state UPS technology, integrating it with digital technology to become the industry standard for rugged devices. Ever since, Clary has been innovating and refining this technology to meet the expanding needs of customers globally. Clary all digital UPS systems are known worldwide for their extreme temperature capability and rugged, reliable design. Clary keeps systems running while protecting sensitive instrumentation and electronics from every power anomaly imaginable.

3

TRAFFIC PRODUCTS The demands of the traffic industry today are noticeably different from the past. Today traffic signal equipment utilizes all the latest technologies including video detection, Bluetooth readers, radar and ethernet/cellular communications, in addition to the most advanced controllers available. It is imperative to protect and keep this equipment running smoothly. There are many different traffic cabinet configurations, with specific power requirements. Fortunately, Clary manufactures various UPS products to satisfy all your power protection needs.

SP 1250LE Designed to enhance utility power or repair failing utility power The SP 1250LE Universal Power Conditioner is a Power Factor Corrected 1250 VA/875 W device designed to enhance utility power or repair failing utility power in traffic, IT or security cabinets. Clary s SP 1250LE can also operate as an On-Line, Dual Conversion UPS when configured with the optional battery pack, which extends the reliability of the cabinet when the utility power fails (black out) or falters (brownout). The SP 1250LE system also protects the cabinet by insuring that no harmful power artifacts arrive at the cabinet to destroy or degrade the cabinet electronics. Clary s industry proven On-Line, true sine wave power protects the cabinet 100% of the time to insure reliable and continuous error-free operation. The SP 1250LE operates in extreme environments from -40 C to +74 C (-40 F to 165 F), and communicates via USB with monitoring center or other equipment. Power quality analytical data is recorded and exportable to Excel in CSV format. Electrical Input 120 VAC (85 VAC to 155 VAC before going to battery, when configured with batteries) 40 Hz to 70 Hz Electrical Output 120 VAC ±3% 50 Hz or 60 Hz 10.4 A Rating 1250 VA/875 W Crest Factor Ratio 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1 Mechanical Input IEC 320, C14 male connector Outputs IEC 320, C13 female receptacles (2) Dimensions H W D (in) 1.7 15.25 8.5 (1U) Weight (lb) 8 Cooling Low velocity, Forced air Design Certifications FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VA, NEMA Typical Recharge Time to 85% 3 to 5 hrs (with extended battery option) Capacity @ 100% Load THD 3.00% Dynamic Response ±4% for 100% step load change 0.5 ms recovery time Control and Indicators Visual Indicators Battery status, AC output, AC input, Alarm Overload 110% for 10 sec; 200% for 50 ms Switches / Control Panel System power, Cold start, Load I, Load II Environmental Audible Alarms Utility interrupt, Inverter failure, Overload, Low battery Temperature 40 C to +74 C ( 40 F to +165 F) Intelligent Computer Interfaces 1 each DB9 F (RS232 and signal interface pins) and 1 each USB Humidity 0% to 95% non condensing Altitude Sea level to 10,000 ft 5

SP 1250LX Built with integrated PIM and programmable display The SP 1250LX products feature an integrated Power Interface Module (PIM) and programmable display. The LX Series are advanced Uninterruptible Power Systems (UPS) that provide clean, regulated Dual Conversion power for controllers and other sensitive equipment inside the cabinet. Available in 3 models in 1250 VA/875 W, the LX Series has an operational temperature range of -40 C to +74 C (-40 F to 165 F), and is compatible with most existing traffic cabinets, meeting all NEMA temperature specifications. Optional NEMA 3R Type II and Type III cabinets are available. The SP 1250LX provides full operation in intersections with all LEDs. Advanced communication features allow monitoring, configuration and control of the system over RS232, modem or network connections. Electrical Input Mechanical 75 VAC to 155 VAC (before going to batteries) Input Hardwired to PIM 45 Hz to 65 Hz Outputs Hardwired to PIM, with single 15 Amp receptacle Electrical Output Dimensions H W D (in) 3.5 19.0 10.0 (1U) 120 VAC ±3% Weight (lb) 27 50 Hz or 60 Hz Cooling Low velocity, Forced air 10.4 A Design Rating 1250 VA/875 W Crest Factor Ratio 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1 THD 4.00% maximum Standard Features Power factor corrected input, Fully regenerative, True on line continuous power, Low distortion sine wave output, Designed for non linear loads, Extended brownout protection, EIA/RS232 data interface Dynamic Response ±4% for 100% step load change 0.5 ms recovery time Certifications FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VA, NEMA Overload UPS Protection 110% for 10 sec; 200% for 50 ms Input and output short circuit; input and output overload; excessive battery discharge Typical Recharge Time to 85% Capacity @ 100% Load Control and Indicators 48 72 hrs (more time required with extended battery option) Environmental Temperature Humidity Altitude 40 C to +74 C ( 40 F to 165 F) 0% to 95% non condensing Sea level to 10,000 ft Switches / Control Panel Audible Alarms Intelligent Computer Interfaces System power, Cold start, Test, Alarm silence, Four line LCD display panel Utility interrupt, Inverter failure, Overload, Low battery, Self test Serial interface for EIA 232, 1 each DB9 F (RS232 and signal interface pins) and 1 each USB, Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software), NTCIP and TCP/IP ready Contact Closures D connector, Open collector (see user manual for additional interface information) 6

SP 2000LX Ideal solution for large diamond intersections The SP 2000LX products feature an integrated Power Interface Module (PIM) and programmable display. The LX Series are advanced Uninterruptible Power Systems (UPS) that provide clean, regulated Dual Conversion power for controllers and other sensitive equipment inside the cabinet. Available in 2 models rated 2000 VA/1400 W, the LX Series has an operational temperature range of 40 C to +74 C ( 40 F to +165 F), and is compatible with most existing traffic cabinets, meeting all NEMA temperature specifications. Optional NEMA 3R Type II and Type III cabinets are available. The SP 2000LX provides full operation in intersections with all LEDs. Advanced communication features allow monitoring, configuration and control of the system over RS232, modem or network connections. Electrical Input Mechanical 75 VAC to 155 VAC (before going to batteries) Input Hardwired to PIM 45 Hz to 65 Hz Outputs Hardwired to PIM, with single 15 Amp receptacle Electrical Output 120 VAC ±3% Dimensions H W D (in) Design 3.5 19.0 10.0 (1U) Rating 50 Hz or 60 Hz 10.4 A 2000 VA/1400 W Standard Features Power factor corrected input, Fully regenerative, True on line continuous power, Low distortion sine wave output, Designed for non linear loads, Extended brownout protection, EIA/RS232 data interface Crest Factor Ratio 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1 Certifications FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VA, NEMA THD Dynamic Response Overload UPS Protection Environmental Temperature Humidity 4.00% maximum ±4% for 100% step load change 0.5 ms recovery time 110% for 10 sec; 200% for 50 ms Input and output short circuit; input and output overload; excessive battery discharge 40 C to +74 C ( 40 F to 165 F) 0% to 95% non condensing Typical Recharge Time to 85% Capacity @ 100% Load Control and Indicators Switches / Control Panel Audible Alarms Intelligent Computer Interfaces 48 72 hrs (more time required with extended battery option) System power, Cold start, Test, Alarm silence, Four line LCD display panel Utility interrupt, Inverter failure, Overload, Low battery, Self test Serial interface for EIA 232, 1 each DB9 F (RS232 and signal interface pins) and 1 each USB, Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software), NTCIP and TCP/IP ready Altitude Sea level to 10,000 ft Contact Closures D connector, Open collector (see user manual for additional interface information) 7

SP Series PD The UPS preference for traffic back-up in many states Clary s SP Series Model PD products feature an integrated PIM and programmable display. The SP Series Model PD are the world s most advanced Uninterruptible Power Systems (UPS). Industry proven, SP Series Model PD systems provide clean, regulated double-conversion power for controllers and other sensitive equipment inside the cabinet, 100% of the time. Clary can provide systems which will sustain a continuous 1400 VA/1800 watt load. Listed by many states as the preferred UPS system for traffic intersection back-up, Clary products are engineered to meet NEMA standards for traffic back-up systems with an operational temperature range of -40 C to +74 C. Clary SP Series are also designed to mount in existing traffic cabinets or in adjacent stand alone cabinets. Optional NEMA 3R Type II and Type III cabinets are available. Advanced communication features allow monitoring, configuration and control of the system over RS232, modem or network connections. See our SNMP Product Brochure. Available for both NEMA and 332 style cabinets. Electrical Input Mechanical 120 VAC +12% (135 VAC), 25% (90 VAC) (before battery use) Input Utility Hardwired to PIM 48 Hz to 62 Hz Outputs Hardwired to PIM, with single 15 Amp receptacle Electrical Output Design 120 VAC +3% 50 Hz or 60 Hz 10.4 A SP 1250PD: 1250 VA/875 W SP 1250PD Plus: 1250 VA/875 W (1400 for 10 seconds) Rating SP 2000PD: 2000 VA/1400 W SP 2400PD: 2400 VA/1800 W Crest Factor Ratio 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1 THD 4.00% maximum Dynamic Response ±4% for 100% step load change 0.5 ms recovery time Overload 110% for 10 sec; 200% for 50 ms Standard Features Certifications Typical Recharge Time to 85% Capacity @ 100% Load Control and Indicators Ramping LEDs Single LED s Switches / Control Panel Power Factor Corrected Input; Fully Regenerative; True On Line Continuous Power; Low Distortion Sinewave Output; Designed for Non linear Loads; Extended Brownout Protection; EIA/RS232 Data Interface FCC Class A, IEEE 587/ANSI C62.41, IEC 555@ 120 VAC, NEMA 48 72 hrs (more time required with extended battery option) Less than 20 hrs with optional Fast Battery Charger Battery level; Load level AC In; Inverter On; Low Battery and Summary Alarm; Alarm Silence System power, Cold start, Test, Alarm silence, Event counter with reset, Hour meter, Battery disconnect UPS Protection Environmental Temperature Input and output short circuit; input and output overload; excessive battery discharge 40 C to +74 C ( 40 F to +165 F) Audible Alarms Intelligent Computer Interfaces Utility interrupt, Inverter failure, Overload, Low battery, Self test Serial interface for EIA 232, 1 each DB9 F (RS232 and signal interface pins) and 1 each USB, Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software), NTCIP and TCP/IP ready Humidity Altitude 0% to 95% non condensing Sea level to 10,000 ft (some derating of temp. w/altitude > 6,000 ft) Contact Closures D connector, Open collector for remote annunciation of power up, power down, on battery, low battery and alarms 8

SP 170 PDA The only combination UPS and PDA in the marketplace Clary s SP 170-PDA is another in a series of the world s most advanced Uninterruptible Power Systems (UPS), designed to provide clean regulated power to controllers and other sensitive equipment inside the cabinet. Industry proven, the SP 170-PDA meets or exceeds CalTrans PDA Requirements with on-line, double-conversion protection 100% of the time for reliable, continuous, and errorfree operation regardless of utility power quality. Available in 3 models from 1250 VA/875 watts to 2000 VA/1400 watts, the SP 170-PDA has an operational temperature range of -40 C to +74 C (-40 F to +165 F), and will fit inside most existing cabinets, meeting all NEMA temperature specifications. Options are available to accommodate intersections that have not yet replaced the yellow incandescent traffic lamps. Additionally, Clary can provide a SP 170-PDA/2000 system that will sustain a continuous 1400 watt load. Advanced communication features allow monitoring, configuration and control of the system over RS232, modem or network connections. See our SNMP Product Brochure. Available for both NEMA and 332 style cabinets. Electrical Input Design 120 VAC +12%, 25% (without battery discharge) 48 Hz to 62 Hz Electrical Output 120 VAC ±3% 50 Hz or 60 Hz Crest Factor Ratio 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1 THD 4.00% maximum Dynamic Response ±4% for 100% step load change 0.5 ms recovery time Standard Features Certifications Typical Recharge Time to 85% Capacity @ 100% Load Control and Indicators Ramping LEDs Single LEDs Power factor corrected input, Fully regenerative, True on line continuous power, Low distortion sine wave output, Designed for non linear loads, Extended brownout protection, EIA/RS232 data interface FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VA, NEMA 48 72 hrs (more time required with extended battery option), < 20 hrs (with optional fast battery charger) Battery level, Load level AC in, Inverter on, Low battery, Summary alarm, Alarm silence Overload UPS Protection 110% for 10 sec; 200% for 50 ms Input and output short circuit; input and output overload; excessive battery discharge Switches / Control Panel Audible Alarms System power, Cold start, Test, Alarm silence, Event counter with reset, Hour meter, Battery disconnect Utility interrupt, Inverter failure, Overload, Low battery, Self test Environmental Temperature Humidity -40 C to +74 C (-40 F to +165 F) 0% to 95% non condensing Intelligent Computer Interfaces Serial interface for EIA 232, Optional NTCIP and TCP/IP via standard RJ45 connector, Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software), NTCIP and TCP/IP ready Altitude Noise Level Sea level to 10,000 ft 46 dba at 5 ft Contact Closures D connector, Open collector (see user manual for additional interface information) Mechanical Configurations Input Outputs Cabinet Hardwired to chassis terminal block Hardwired to chassis terminal block NEMA or 332 cabinet style configurations available Model VA W Input Output Rating Backup Time* 100%/50% Load SP 170 PDA/2000 2000 1400 14.3 A 20.0 A 2000 VA/1400 W 1.0 hrs/3.5 hrs Rackmount H W D (in) 7.0 19.0 16.0 Weight (lb) 30 SP 170 PDA/1250 Plus 1250 875 8.8 A 10.4 A 1250 VA/875 W or 1400 W for 10 seconds 1.5 hrs/4.0 hrs SP 170 PDA/1250 1250 875 8.8 A 10.4 A 1250 VA/875 W 1.5 hrs/4.0 hrs * Backup time is based on 41 Ahr batteries 9

ITS/SECURITY/ PUBLIC SAFETY/ MILITARY PRODUCTS Protecting and monitoring the general populace in this age of uncertainty demands a network that is reliable and fail-safe. Clary manufactures products perfect to provide uninterruptable power protection to PTZ cameras, NVRs, DVRs, digital message signs, gates, biometric readers, RFID readers and many more applications. When your networks require the best protection, use the brand the US Navy has chosen for over 30 years.

SP 560 Compact UPS that delivers big time protection The compact SP 560 from Clary delivers on-line protection 100% of the time, for reliable, continuous error-free operation, regardless of utility power quality. Occupying only 1U of vertical rack space, it can fit into any cabinet. Clary s SP 560 is a 560 VA/400 W power source built for electronics equipment in IT, traffic and security applications, delivering constant, conditioned, regenerated AC power. It protects equipment from being disrupted, degraded or damaged due to harmful power events. Clary power conditioning completely isolates the cabinet from utility power enabling error-free operation during surges, sags, spikes, and other power anomalies. With an optional battery pack, the SP 560 system operates as an On-Line, Double-Conversion UPS, extending the reliability of the cabinet s electronics during utility power failures (black-outs). The SP 560 is Power Factor Corrected to reduce utility current draw and wiring requirements. Designed for indoor/outdoor use, the Clary SP 560 will operate in temperature extremes from -40 C to +74 C (-40 F to 165 F) and it communicates locally or remotely via serial, USB or an optional web agent. Electrical Input 120 VAC (85 VAC to 155 VAC before going to battery, when configured with batteries) Electrical Output 120 VAC ±3% Software selectable to sync with input utility or run at crystal controlled 50/60 Hz ±1 Hz 4.8 A Rating 560 VA/400 W Crest Factor Ratio 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1 Mechanical Input IEC 320, C14 male connector Outputs IEC 320, C13 female receptacles (2) Dimensions H W D (in) 1.7 11.0 8.5 (1U) Weight (lb) 5 Cooling Low velocity, Forced air Design Power factor corrected input, Fully regenerative, True on line Standard Features continuous power, Low distortion sine wave output, Designed for non linear loads, Extended brownout protection THD 3.00% Certifications FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VA, NEMA Dynamic Response Overload UPS Protection ±4% for 100% step load change 0.5 ms recovery time 110% for 10 sec; 200% for 50 ms Input and output short circuit; input and output overload; excessive battery discharge Typical Recharge Time to 85% Capacity @ 100% Load Control and Indicators Visual Indicators 3 to 5 hrs (with extended battery option) Battery status, AC output, AC input, Alarm Environmental Switches / Control Panel System power, Cold start, Load I Temperature 40 C to +74 C ( 40 F to +165 F) Audible Alarms Utility interrupt, Inverter failure, Overload, Low battery Humidity Altitude 0% to 95% non condensing Sea level to 10,000 ft Intelligent Computer Interfaces External Battery Pack 1 each DB9 F (RS232 and signal interface pins) and 1 each USB SP 485B Battery Pack - External battery pack for SP 560 and SP 1250LE. Same compact design. Ideal for runtime requirements less than an hour. 11

SP 1250DLE Clean power for the next generation Our newest Digital UPS is designed for ITS/Traffic Applications, including the new low-voltage ATC Cabinets. It s the only double conversion, true On-Line UPS with both AC and DC power inputs and outputs, and it comes in a compact 1U rack-mounted package. The SP 1250DLE is designed for temperature extremes of 40 C to +74 C ( 40 F to +165 F) and supports 85 155 VAC or 48 VDC input voltages, as well as generator input. The unit provides a 120 VAC output and 48 VDC, 24 VDC, and 12 VDC outputs, up to an 875 watt maximum for all outputs combined. For customers who do not yet require DC support but anticipate a future need, the SP 1250DLE can be ordered without DC output and later upgraded in the field. Preliminary Specifications* Electrical Input Outputs - General Input #1 Total Power 875 W maximum all outputs combined 85-155 VAC Overload 110% for 10 mins 60 Hz ±5 Hz Isolation AC, 48 VDC and 24/12 VDC isolated from each other Power Factor Power Factor Corrected Protection Short Circuit & Overload Input #2 Environmental 48 VCD Nominal Battery Pack Temperature 40 C to +74 C ( 40 F to +165 F) Isolation Thru-neutral design Humidity 95% maximum, non condensing Electrical Output Altitude -1000 to 10,000 ft Output #1 - AC 120 VAC ±3% *Please visit Clary.com for current specifications VA / Power Harmonic Distortion Isolation Protection 60 Hz 1250 VA/875 W 5% THD maximum Thru-neutral design Short Circuit & Overload Output #2A - DC 48 VDC ±3% Power 8 A 400 W Output #2B - DC 24 VDC ±3% Power 6 A 144 W Output #2C - DC 12 VDC ±3% Power 6 A 72 W 12

DT Series Built for extreme temperatures for applications where others have failed The DT Series ET is a digital Uninterruptible Power System (UPS) which features Clary s On-Line Double Conversion, Power Factor Corrected technology built for extreme temperature. Not only does the DT Series ET offer the highest reliability available on the market today, we consider it On-Line Double Conversion technology at its best. We ve built this system for that application where all others have failed due to extreme indoor or outdoor environmental conditions. Operating in temperatures from -40 C to +74 C, the UL listed DT Series ET is ideal for those areas not environmentally controlled and in remote locations. All DT Series ET systems utilize Power Factor Correction, and RS232 and SNMP protocols are supported. Available in rack-mount configurations with extended battery run times, custom configurations and engineering available. Clary s DT 1000R(ET) is the world s most advanced Uninterruptible Power System (UPS) for extreme environment applications. The DT 1000R(ET) keeps equipment running for 10 minutes to 10 hours or more dependent upon optional battery sizing, during power failures. See website for other DT Series products. Electrical Input Design 120 VAC +12%, 25% (without battery discharge) 45 Hz to 65 Hz 7.2 A Electrical Output 120 VAC ±3% Software selectable to sync with input utility or run at crystal controlled 50/60 Hz ±1 Hz 8.3 A Crest Factor Ratio 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1 Dynamic Response ±4% for 100% step load change 0.5 ms recovery time Overload 110% for 10 sec; 200% for 50 ms Standard Features Certifications Typical Recharge Time to 85% Capacity @ 100% Load Control and Indicators Ramping LEDs Single LEDs Power factor corrected input, Fully regenerative, True on line continuous power, Low distortion sine wave output, Designed for non linear loads, Extended brownout protection, RS232 data interface, Inverter powers load continuously, Continuous operation on 25% to +12% utility without draining batteries, Automatic bypass, AC output (2 channel load control), Rear mounted ground stud FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VA, CUL, UL 1778 8 hrs (more time required with extended battery option) Battery level, Load level AC in, Inverter on, Summary alarm, Alarm silence, Load on UPS Protection Environmental Temperature Humidity Altitude Input and output short circuit; input and output overload; excessive battery discharge 40 C to +74 C ( 40 F to +165 F) 0% to 95% non condensing Sea level to 10,000 ft Switches / Control Panel Audible Alarms Intelligent Computer Interfaces Contact Closures System power, Cold start, Load I, Load II, Test, Alarm silence Utility interrupt, Inverter failure, Overload, Low battery, Self test Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software) Open collector (see user manual for additional interface information) Noise Level Mechanical 46 dba at 5 ft Optional SNMP Interface Allows full control and monitoring interface over network connection. Compatible with HP Openview, IBM Netview, CA Unicenter TNG, and other major software offerings. Input NEMA 5 15P plug with 6 ft cord Outputs 5 15R receptacles Rackmount H W D (in) 5.25 19.0 18.0 (2U) Weight (lb) 30 Configurations Model VA W Input Output Rating Backup Time* 100%/50% Load DT 1000R ET 1000 700 7.2 A 8.3 A 1000 VA/700 W 5.0 mins/17.0 mins * Backup time is based on 41 Ahr batteries 13

CMN Series Built for military applications, designed to work in the most extreme environments The Clary CMN Series Uninterruptible Power Systems are built specifically for fixed and mobile military applications. Clary s industrial grade CMN Series are designed and assembled to perform at the highest level in extreme temperatures and rugged environments. All systems are true on-line products which are digitally microprocessor controlled to provide clean, regulated power under all tactical conditions. All CMN Series systems are Power Factor Corrected (PFC) in real-time to ensure the highest possible efficiency. Full RS232 and SNMP interactive communications capability assures support of all types of command and control applications. 1250/1500/2000/2400/3000 and 4000 VA; 120 through 240 VAC input 45 to 65 Hz, 120 through 240 VAC output; 50 or 60 Hz. UL listed. CMN Series products manufactured for US Navy consumption meet Mil Standards including: 167 and 901D for Shock And Vibration and CS101, 116, CE101, 102 for Radiated & Conducted EMI and FCC Class A specifications. Electrical Input Design 120 VAC +12%, 25% (without battery discharge) 45 Hz to 65 Hz Electrical Output 120 VAC ±3% Standard Features Power factor corrected input, Fully regenerative, True on line continuous power, Low distortion sine wave output, Designed for non linear loads, Extended brownout protection, RS232 data interface, Inverter powers load continuously, Continuous operation on 25% to +12% utility without draining batteries, Automatic bypass, AC output (8 channel load control), Rear mounted ground stud Software selectable to sync with input utility or run at crystal controlled 50/60 Hz ±1 Hz Certifications FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VA, CUL, UL 1778 Crest Factor Ratio 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1 THD 3.00% maximum (linear), 5.00% maximum (non linear) Dynamic Response ±4% for 100% step load change 0.5 ms recovery time Overload 110% for 10 sec; 200% for 50 ms Input and output short circuit; input and output UPS Protection overload; excessive battery discharge Environmental Temperature 40 C to +74 C ( 40 F to +165 F), 0 C to +50 C (+32 F to +122 F) Humidity 0% to 95% non condensing Altitude Sea level to 10,000 ft Noise Level 46 dba at 5 ft Mechanical Input Consult factory Typical Recharge Time to 85% Capacity @ 100% Load Control and Indicators Ramping LEDs Single LEDs Switches / Control Panel Audible Alarms Intelligent Computer Interfaces Contact Closures Optional SNMP Interface 8 hrs (more time required with extended battery option) Battery level, Load level AC in, Inverter on, Summary alarm, Alarm silence, Load on System power, Cold start, Load I, Load II, Test, Alarm silence Utility interrupt, Inverter failure, Overload, Low battery, Self test RS 232 data interface (DB 9), Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software), Compatible with Systems Enhancement UPS control software DB 9, Open collector Allows full control and monitoring interface over network connection. Compatible with HP Openview, IBM Netview, CA Unicenter TNG, and other major software offerings. Outputs Rackmount H W D (in) Weight (lb) Consult factory 5.25 19.0 23.0 (3U) CMN 3000 & 4000 ET/ST: 90 CMN 2400 ET/ST: 83.5 CMN 2000, 1500, & 1250 ET/ST: 80 Configurations Model VA W Input Output Rating Backup Time* 100%/50% Load CMN 3000 ET/ST 3000 2100 28.0 A 25.0 A 3000 VA/2100 W Battery option dependent CMN 4000 ET/ST 4000 2800 42.0 A 34.0 A 4000 VA/2800 W Battery option dependent CMN 2400 ET/ST 2400 1680 18.3 A 20.0 A 2400 VA/1680 W 4.0 mins/12 mins CMN 2000 ET/ST 2000 1400 14.3 A 16.7 A 2000 VA/1400 W 5.0 mins/18.0 mins CMN 1500 ET/ST 1500 1050 10.7 A 12.5 A 1500 VA/1050 W 5.0 mins/17.0 mins CMN 1250 ET/ST 1250 875 8.8 A 10.4 A 1250 VA/875 W 7.0 mins/21.0 mins * Backup time is based on 41 Ahr batteries 14

CT Series Designed for extreme environments, built for mission critical applications Clary s core competency is our ability to create a customizable Uninterruptible Power System (UPS) solution, tailored for a customer s unique mission critical application. In fact, we are the only manufacturer of On Line Double Conversion UPS systems that offer selectable features to meet specific application needs. A wide selection of features includes input/output isolation, switchable voltages, auto sense capability, input circuit breaker protection, and input/output termination selection options. The rugged CT Series is designed for extreme applications, such as offshore drilling rigs, refineries and shipboard use. An added benefit is that the CT Series can double as an electronic power conditioner/ frequency converter as well. All CT systems utilize Power Factor Correction, and RS232 and SNMP protocols are supported. Available in a 3U rack mount configuration with extended battery options, the CT Series is UL listed. Custom configurations and engineering available, so various input/ output voltages are available beyond the standard ratings of 1250/1500/2000 and 2400 VA. Clary will build each system to order, and many customized options are available. Please contact Clary and see how we can meet your unique requirements. Electrical Input Design 120 VAC +10%, 20% (other input voltages available) 45 Hz to 65 Hz Electrical Output 120 VAC ±3% Standard Features Power factor corrected input, Fully regenerative, True on line continuous power, Low distortion sine wave output, Designed for non linear loads, Extended brownout protection, RS232 data interface, Inverter powers load continuously, Continuous operation on 25% to +12% utility without draining batteries, Automatic bypass, AC output (2 channel load control), Rear mounted ground stud Software selectable to sync with input utility or run at crystal controlled 50/60 Hz ±1 Hz Crest Factor Ratio 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1 THD 3.00% maximum (linear), 5.00% maximum (non linear) Dynamic Response ±4% for 100% step load change 0.5 ms recovery time Overload 110% for 10 sec; 200% for 50 ms Input and output short circuit; input and output UPS Protection overload; excessive battery discharge Environmental Temperature 0 C to +40 C (+32 F to +104 F) Humidity 0% to 95% non condensing Altitude Sea level to 10,000 ft Noise Level 39 dba to 42 dba at 5 ft Mechanical NEMA 5 15P plug with 6 ft cord (1250 1500 VA connectors), Input NEMA 5 20P plug on 6 ft cord (2000 2400 VA connectors) Outputs NEMA duplex receptacles 5 15R, 1.25K 1.5K, 5 20R, 2K 2.4K Rackmount H W D (in) 5.25 19.0 23.0 (3U) CT 2400R & CT 2000R: 92 Weight (lb) CT 1500R & CT 1250R: 79 Certifications FCC Class A, IEEE 587/ANSI C62.4, IEC 555@ 120 VA, CUL, UL 1778 Typical Recharge Time to 85% Capacity @ 100% Load 5 hrs Control and Indicators Ramping LEDs Single LEDs Switches / Control Panel Audible Alarms Intelligent Computer Interfaces Contact Closures Optional SNMP Interface Configurations Model VA W Battery level, Load level AC in, Inverter on, Summary alarm, Alarm silence, Load on System power, Cold start, Load I, Load II, Test, Alarm silence Utility interrupt, Inverter failure, Overload, Low battery, Self test RS 232 data interface (DB 9), Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software), Compatible with RUPS and RUPS II and other major UPS software products DB 9, Open collector, Optional dry contact module Allows full control and monitoring interface over network connection. Compatible with HP Openview, IBM Netview, CA Unicenter TNG, and other major software offerings. Input Output Rating Backup Time* 100%/50% Load CT 2400R 2400 1680 18.3 A 20.0 A 2400 VA/1680 W 5.0 mins/18.0 mins CT 2000R 2000 1400 14.3 A 16.7 A 2000 VA/1400 W 5.0 mins/17.0 mins CT 1500R 1500 1050 10.7 A 12.5 A 1500 VA/1050 W 5.0 mins/18.0 mins CT 1250R 1250 875 8.8 A 10.4 A 1250 VA/875 W 5.0 mins/18.0 mins * Backup time is based on 41 Ahr batteries 15

GT Series Power factor corrected for several voltage inputs The Global Uninterruptible Power System or GT Series, features Clary s On-Line Double Conversion technology, and is Power Factor Corrected for a wide range of voltage inputs, (120 VAC through 240 VAC and 50/60 Hz). Computer terminals, workstations and communication equipment are typical electronic products that will benefit from Clary s GT Series protection. All GT Series Systems support RS232 and SNMP protocols when communication back to the network is required. Available in tower only configurations, many custom configurations are available. Please call Clary to get a specific solution for your application. Ratings: 1250 VA/1500 VA/2000 VA/2400 VA; 120/120 VAC; 50/60 Hz. UL listed. Electrical Input Design Selectable Ranges: 120/208, 120/220,120/230 or 120/240 VAC 48 Hz to 62 Hz Electrical Output 120 VAC +3% 50 Hz or 60 Hz, Software selectable to sync with input utility or run at crystal controlled 50/60 Hz ±1 Hz Crest Factor Ratio 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1 THD 3.00% maximum (linear), 5.00% maximum (non linear) Dynamic Response ±4% for 100% step load change 0.5 ms recovery time Overload 110% for 10 sec; 200% for 50 ms Input and output short circuit; input and output UPS Protection overload; excessive battery discharge Environmental Temperature 0 C to +40 C (+32 F to +104 F) Humidity 0% to 95% non condensing Altitude Sea level to 10,000 ft Noise Level 39 dba to 42 dba at 5 ft Mechanical IEC on unit with 6 ft NEMA 5 15P (1250 1500 VA connectors), Input IEC on unit with 6 ft NEMA 5 20P (2000 2400 VA connectors) Standard Features Certifications Typical Recharge Time to 85% Capacity @ 100% Load Control and Indicators Ramping LEDs, Single LED s Switches / Control Panel Audible Alarms Intelligent Computer Interfaces Contact Closures Optional SNMP Interface Power factor corrected input, Fully regenerative, True on line continuous power, Low distortion sine wave output, Designed for non linear loads, Extended brownout protection, RS232 data interface, Inverter powers load continuously, Continuous operation on 25% to +12% utility without draining batteries, Automatic bypass, AC output (2 channel load control), Rear mounted ground stud FCC Class A, IEEE 587/ANSI C62.4, CUL, UL 1778, CE 8 hrs (more time required with extended battery option) Battery level, Load level AC in, Inverter on, Summary alarm, Alarm silence, Load on System power, Cold start, Load I, Load II, Test, Alarm silence Utility interrupt, Inverter failure, Overload, Low battery, Self test RS 232 data interface (DB 9), Full interactive remote computer monitoring and control of most features including load control (requires optional monitoring software), Compatible with RUPS and RUPS II and other major UPS software products DB 9, Open collector (see user manual for additional interface information) Allows full control and monitoring interface over network connection. Compatible with HP Openview, IBM Netview, CA Unicenter TNG, and other major software offerings. Outputs 5 15R receptacles Dimensions H W D (in) 14.1 6.9 21 GT 2400 & GT 2000: 100 Weight (lb) GT 1500 & GT 1250: 80 Configurations Model VA W Input Output Rating Backup Time* 100%/50% Load GT 2400 2400 1680 18.3 A 20.0 A 2400 VA/1680 W 4.5 mins/14 mins GT 2000 2000 1400 14.3 A 16.7 A 2000 VA/1400 W 5.0 mins/18.0 mins GT 1500 1500 1050 10.7 A 12.5 A 1500 VA/1050 W 5.0 mins/17.0 mins GT 1250 1250 875 8.8 A 10.4 A 1250 VA/875 W 7.0 mins/21.0 mins * Backup time is based on 41 Ahr batteries 16

ACCESSORIES/ COMMUNICATIONS Clary Corporation manufactures many accessories to enhance your ownership experience. This includes communication cards, specialty mounting brackets, bypass switches and cabinets. If your application requires special configurations, do not hesitate to contact Clary Corporation for a consultation.

Outpost Batteries Designed for deep cycle, extreme temperature applications The Outpost batteries are designed for deep cycle, extreme temperature applications. They have been field tested and used for years in the Traffic and ITS market as well as the US Military. Operational from -40 C to +74 C (-40 F to +165 F ) Available in 41, 51 & 105 Ampere-Hour (AH) Ratings. Technology, copolymer polypropylene case and cover developed for use on Military jet fighters. Positive plates special lead calcium. Includes models: OP72C-41, OP96C-41, OP72D-51, OP96D-51, OPB-1241, OPB1251, OPB-12105 Sealed, maintenance free no need to add water absorbed glass mat (AGM) construction microporous spun glass separators: non-spillable, immobilized electrolyte recombinant gas. Battery Information Amp Hour Capacity Runtime (77 F / 25 C) Full Charge Unit Weight Each Overall Dimensions Clary Part # Nominal Volts 20 Hour Rate 300 W 500 W 700 W 875 W lb (kg) Length (L) in (mm) Width (W) in (mm) Height (H) in (mm) OPB 1241 72 VDC Systems 12 VDC 41 Amp/Hr. Batteries 6:30 hrs:min 3:50 hrs:min 2:30 hrs:min 1:50 hrs:min 29 (13.2) 7.72 (196) 5.25 (132) 7.91 (205) OPB 1251 72 VDC Systems 12 VDC 51 Amp/Hr. Batteries 7:40 hrs:min 4:40 hrs:min 3:20 hrs:min 2:30 hrs:min 35 (18.9) 8.99 (228) 5.45 (138) 8.82 (224) OPB 12105 72 VDC Systems 12 VDC 105 Amp/Hr. Batteries 15:00 hrs:min 9:30 hrs:min 6:30 hrs:min 5:10 hrs:min 64 (29.0) 12.9 (327) 6.75 (171) 8.96 (228) 18

Accessories Bypass Switches Switches allows you to bypass the utility power from the Clary UPS to service or remove the installed UPS. Crest Factor Ratio: 50% load up to 4.8:1, 75% load up to 3.2:1, 100% load up to 2.4:1. Several switches are offered. Model depicted is SPH 302. SNMP/HTTP Adapter The optional SNMP/HTTP card functions as an SNMP agent and includes an embedded HTTP server (web server). This means that one industry standard management tool can be used to monitor and control all your UPS systems from one central location, and power management can be integrated into your existing network or building management strategy. Remote View Software Remote View is a client software running as a NMS (Network Management System). Users are provided with tree-view and list-view (Icon style and Report style) to monitor device in this software. User can upload a Map of their city/agency and plot in excess of 1,000 UPS systems deployed. This allows user to monitor all systems deployed from a single platform with visual and broadcast notifications. 19

Enclosures Clary UPS peripheral cabinets are manufactured to the highest standards. Clary enclosures provide a safe watertight environment for traffic control systems. All cabinets are fully ventilated and made to accept generator input. Clary cabinets are NEMA 3R rated and can be manufactured to Caltrans, TEES standards. Clary can deliver standard cabinets or can custom configure them to meet your individual specifications. Manufactured from.125 thick 5052-H32 aluminum. Complete double flanged doorframe. Provisions for mounting forced air fan system with filtered input air. Stainless steel external hardware. Interior finish is anodize coating, Type II Per MIL-A-8625C Doors: Stainless steel door, lockable door handles Louvered air vent with filter and bracket. Door sealed with neoprene gasket. Enclosures are available in various finishes: Natural Aluminum, Anodized, Stainless, Powder Coat, in various colors. Options: CBL-123/CBL-124 Corbin or Best Locks CBB-123 Base Skirt CBP-123 Cabinet Painting/Power Coat CBT-123 Thermal (Thermostat & Fan) 20

Outpost and Signal Power are trademarks of Clary Corporation. Specifications are subject to change without notice. Revised specifications may be available on our website www.clary.com. Designed and built in the USA

150 E Huntington Drive Monrovia, CA 91016 Tel: 800.442.5279 Fax: 626.305.0254 www.clary.com 2016 Clary Corporation 1016