TYPE APPROVAL CERTIFICATE

Similar documents
TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft

EU RO MUTUAL RECOGNITION TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

DET NORSKE VERITAS TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

TYPE APPROVAL CERTIFICATE

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

Protection and Power Management, PPM-3 Display and push-button functions Alarm handling Log list Failure mode and effect analysis

Issued to DISTRIBUIDORA INTERNACIONAL CARMEN, S.A -DICSA- Zaragoza Zaragoza, Spain

DELOMATIC 400, DM-400 HYDRO

HYUNDAI HEAVY INDUSTRIES CO., LTD.

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

TYPE APPROVAL CERTIFICATE

For the compliance with the resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

For compliance with Resolution MEPC.174(58), the Certificate is issued on behalf of the Norwegian Maritime Authority.

EC-TYPE EXAMINATION CERTIFICATE (MODULE B)

AGC 200 Advanced Gen-set Controller OPERATOR S MANUAL

TYPE APPROVAL CERTIFICATE

Indicators for Rudder Angle, Rate of Turn, Propeller Shaft Revolution and Propeller Pitch

Low-voltage switchgear and controlgear - rated voltage does not exceed 1000V AC or 1500V DC

Emergency power automatics MS-2. High resistance to shock, vibrations and transients. All output are 2A relay contacts

SOUND RECEPTION SYSTEM

Shipboard incinerators with capacities up to 4000 kw

SIMPLIFIED VOYAGE DATA RECORDER (S-VDR)

Process Alarm Solutions

Generator Control Unit, GCU 100 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

FPS MANUAL FEEDER PROTECTION SYSTEM

M2000 Engine Controller

Compact Genset Controller, CGC 400 Push-buttons LEDs Display and menu structure Display readings Alarm handling and log list

Adaptive CyCLO Technical and HMI User Guide. CyCLO User Guide. Version th December 2017 REV

Generator Paralleling Controller, GPC-3 Hydro Start and stop sequences, water level control

DEIF A/S. Description of options. Option M17, Configurable inputs and RPM supervision Engine Controller EC-1/EC-1M. Description of option

Notified Body No.: 0575

MARINE GYRO COMPASS STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

Circuit Breakers JANUARY The electronic pdf version of this document found through is the officially binding version

Design. Innovations in Integrated Control Systems

DEIF A/S. Operator s Manual. Basic Gen-set Controller. Display readings. Push-button functions. Alarm handling. Log list C (UK)

Documentation guide to get your plant on the positive list (Category A1/A2)

Notified Body No.: 0098

DEIF A/S. Description of options. Option A4, Loss of mains protection package Automatic Gen-set Controller. Description of option

Electrical Energy department

F-03 FIXED FIRE DETECTION AND FIRE ALARM SYSTEM

GROUNDING AVOIDANCE SYSTEM (GAS)

DNVGL-CP-0407 Edition February 2016

Project: Customer: Engineer: Pump Manufacturer: Model GPY + GPU. with Automatic Power Transfer Switch

1S25. Arc Fault Monitor 4 Zones, 8 Sensors. Features. Introduction. ARC Fault Protection

DNVGL-CP-0402 Edition February 2016

Model VPS Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass

Drawing Submittal Package

TraceNet ECM Series Control System

Engine Control Unit, ECU 100 Functional description Additional functions Parameter list

7XG3120 ReyArc20 Arc Fault Monitor Relay Energy Management

DNVGL-CP-0398 Edition December 2015

PHYSICAL FACILITIES Consultant s Handbook Specifications Division 21 Fire Suppression 3000 Fire Pumps

Arc Fault Protection System D1000

Notified Body No.: 0575

D1000 Arc-fault Protection System

GUIDE TO APPROVAL OF RETROFIT BALLAST WATER MANAGEMENT SYSTEM INSTALLATIONS

Technical Data Submittal Document

INTERNATIONAL STANDARD

Model VPS + VPU Pressure Limiting (VFD) Electric Fire Pump Controller with Soft Start Bypass with Automatic Power Transfer Switch

Drawing Submittal Package

Table of Contents. Protective Relays

Notified Body No.: 0575 G U A D N L. SJq

Replaceable LED modules. Sleep or unattended mode. Auto-silence and auto-acknowledge

C Command. Engine monitoring that puts you in control

SHOP PRIMERS FOR CORROSION PROTECTION OF STEEL PLATES AND SECTIONS

Electrical installation solutions for buildings Technical details Energy efficiency

Option M16.x Configurable I/O extension cards, four multi-inputs (4-20 ma/0-5 V/Pt100) Description of option Functional description

DEIF A/S. Technical Manual. Type EC-2 Engine Control Unit D. Technical Manual

Certification Report of the ST 3000 Pressure Transmitter with HART 6

For Complete Fire and Gas Solutions

M2500 Engine Controller Installation Manual

INTERNATIONAL STANDARD

MO n : 12JMC rév A

Certification Report of the ST3000 Pressure Transmitter

Carbon Monoxide Transmitter

APRIL 2010 ELECTRICAL EQUIPMENT STANDARD FOR CERTIFICATION DET NORSKE VERITAS. No. 2.9 Type Approval Programme No

PRODUCTS AND SOLUTIONS FOR PUMPING, IRRIGATION AND PIPING

STANDARDS UPDATE NOTICE (SUN) ISSUED: August 23, 2017

C-Bus Four Channel Analogue Output Unit Installation Instructions

Item/clause/Page no. Description as per tender. To be read as

CTT8 TEMPERATURE MONITOR DEVICE

Addendum HART Communication with the X2200 UV Flame Detector 1.1 4/

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

RADAR REFLECTOR STANDARD FOR CERTIFICATION. DET NORSKE VERITAS Veritasveien 1, N-1322 Høvik, Norway Tel.: Fax:

M1000 Alarm Annunciator

VACUUM BREAKER MEDIUM VOLTAGE AUTOMATIC TRANSFER SWITCHES

Remote NAC Power Supply D7038

COMITÉ EUROPÉEN DES ASSURANCES

Modbus RTU RS485 Manual

Transcription:

TYPE APPROVAL CERTIFICATE Certificate No: TAA00000VH This is to certify: That the Power Management System with type designation(s) Delomatic 4 Issued to DEIF A/S SKIVE, Denmark is found to comply with DNV GL rules for classification Ships, offshore units, and high speed and light craft Application : Product(s) approved by this certificate is/are accepted for installation on all vessels classed by DNV GL. Location classes: Temperature B Humidity B Vibration A EMC A Enclosure B* * for display and operation panels only, for mounting rack and PCB-modules required protection according to the Rules to be provided upon installation on board This Certificate is valid until 2018-11-28. Issued at Høvik on 2016-11-29 DNV GL local station: Aalborg for DNV GL Approval Engineer: Bartosz Kabak Odd Magne Nesvåg Head of Section This Certificate is subject to terms and conditions overleaf. Any significant change in design or construction may render this Certificate invalid. The validity date relates to the Type Approval Certificate and not to the approval of equipment/systems installed. Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 1 of 6 DNV GL 2014. DNV GL and the Horizon Graphic are trademarks of DNV GL AS.

Place of system modules manufacture DEIF A/S Skive Denmark Product description The Delomatic 4 system is based on the following hardware modules: PCM 4-1 and PCM 4-5, power supply, control and communication i/f module IOM, input /output module with 16 AI/DI, 12 RO and 2 AO SCM 4-1 and SCM 4-2, synchronising, control and 3-phase AC measuring module, and optionally (SCM 4-2) outputs for control of governor and AVR DU, operation and display panel with LCD and pushbuttons AOP, additional operation and display panel, with LEDs and pushbuttons (AOP-1 mounted next to the DU, AOP-2 up to 500 m away) The display/operation units (DU/AOP) are for flush-mounting in panel fronts. The other modules are mounted in DGU-racks. Four different rack-sizes are available to match the number of IOMs/SCMs (up to 4 SCMs per rack). Maximum number of DGU-racks per system is 15. The same project specific software is installed in all PCMs. The software is identified by project, version and revision numbers. These numbers together with the download date and time can be displayed in the DU. The software is uniquely identified by project and version. A system will include one or more of the following functions: multifunction circuit protection voltage and frequency monitoring for generators and busbars diesel engine protection AC metering power management including load dependent start/stop with priority, auto-synchronising, symmetrical/asymmetrical load sharing, trip of non-essential consumers, blackout restoration sequence, heavy consumer control, etc. The following software modules are covered by the Type Approval: 1.1 Internal System Supervision Basic Arcnet Feature 1.2 Internal System Supervision Split Arcnet Feature 2.1 Power Management Functions Basic Plant Mode 2.2 Power Management Functions Split Plant Mode 2.3 Power Management Functions Thruster Control 2.4 Power Management Functions Heavy Consumer 3.1 Diesel Generator Control Functions 3.2 Diesel Generator Protection Functions 4.1 Tie Breaker Control Functions 4.2 Tie Breaker Protection Functions 5.1 Shaft Generator/Shore Connection Control Functions 5.2 Shaft Generator/Shore Connection Protection Functions 6.1 Aux. Tie Breaker Control Functions 6.2 Man. Tie Breaker Supervision Functions 6.3 Shore Connection Breaker Supervision Functions 6.4 Aux. Circuit Breaker Supervision Functions 7.1 Emergency/Harbour Generator Control Functions 7.2 Emergency/Harbour Generator Protection Functions 8.1 User Interface Functions - Display Units and Additional Operation Panels AOP s 9.1 Alarm Handling Functions 10.1 Data Communications Interface Functions Modbus Communication 10.2 Data Communications Interface Functions CAN Open Communication 10.3 Data Communications Interface Functions Engine Communication Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 2 of 6

10.4 Project Specific Data Communications Interface Functions The following alarm and protection functions as defined by ANSI are available: following alarm and protection functions as defined by ANSI are available: Protection function ANSI no. Levels Speed supervision device (15) 1 step Overexcitation (24) 2 steps Synchronous check device (25) 1 step Automatic synchronizing (25 A) Generator undervoltage (27) 1 step Busbar undervoltage (27 B) 2 steps Generator overload (32) 2 steps Generator reverse power (32_R) 2 steps Loss of excitation (40) 2 steps Current unbalance (46) 1 steps Phase sequence voltage (47) 1 step Circuit breaker failure (50BF) 1 step Generator overcurrent (50) 4 steps Overcurrent, def. time, IDMT (51) Voltage-dependent overcurrent (51V) 1 curve Generator overvoltage (59) 2 steps Busbar overvoltage (59 B) 2 steps Voltage unbalance (60) 1 steps Number of start (66) Blocking (engine start/synchronisation) (68) 1 step Auto reclosing (79) Generator overfrequency (81) 2 steps Generator underfrequency (81) 2 steps Busbar overfrequency (81 B) 2 steps Busbar underfrequency (81 B) 2 steps Locking-out relays, electronic (86) Several Speed, frequency and active load control device (90) Volt and reactive load control device (90) Tripping relay (94) Advanced generator protection: - Engine, governor or fuel failure - Generator or AVR failure (95) Application/Limitation 1. The Type Approval is valid for systems made by production facilities listed under Place of Manufacture 2. The Type Approval covers hardware and software listed under Product description. 3. The possibility of protecting more than one circuit by a single DGU is not to be used when the separation requirements in Pt.4 Ch.8 Sec.2 [7.2.1] a) to c) applies: Each separate circuit shall be protected against overcurrent and short circuit (Interpretation of SOLAS Ch. II-1/45.6.1). 4. For high speed vessels category B (ref. Pt.4 Ch.8 Sec.2 [6]) the Delomatic-4 system must be configured so as to ensure that the power management functions are active for each busbar section when the bustie breaker is open. Also, the communication network between DGUs for one busbar section must not be affected by a defective communication network for the other busbar section. Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 3 of 6

Documentation requirement: For each delivery where the product is included (typically a switchboard) the following information related to the Delomatic-4 system is to be submitted for approval: - Reference to this Type Approval Certificate - System block diagram - Power supply arrangement (may be part of the System block diagram) - List of hardware and software modules as identified in this Type Approval Certificate - Functional description including functions provided through AOP(s) if provided - Project specific list of control and monitoring points (I/O list) - List of implemented alarm and protection functions (ref. the ANSI list above) with proposed limits and time delays - Test program for test at DEIF, the switchboard maker or onboard as applicable Product certificate Each delivery of the application system is to be certified according to Pt.4 Ch.9 Sec.1. The certification test is to be performed before the system is shipped to the yard, that is, at the manufacturer of the application system or at the switchboard manufacturer if agreed and adequate system competence and test facilities are available here. If certified together with the switchboard a combined control system and switchboard certificate may be issued. The certificate must identify this Type Approval Certificate plus the firmware by versions and date. After the certification the clause for application software control will be in force: Clause for application function control All changes in software are to be recorded as long as the system is in use on board. The records of all changes are to be forwarded to DNV GL for evaluation and approval. Major changes in the software are to be approved before being installed in the computer. Certification of Application Functions may be required. Software update notification When the type approved software is revised (affecting all future deliveries) DNV GL is to be informed by forwarding updated software version documentation. If the changes are judged to affect functionality for which rule requirements apply a new functional type test may be required and the certificate may have to be renewed to identify the new software version. Type Approval documentation Software_Modules_43xxxx0194A.pdf DM4 SW description, main document.pdf A) APPLICATION SOFTWARE MODULES DELOMATIC 4 B) APPLICATION SOFTWARE CHANGES OVERVIEW DELOMATIC 4 C) DM4 Datasheet (4921240294B) D) DM4 Technical documentation Part1 (461711 project specific part) Da) Introduction to the present system (43xxxx0101E) Db) The present power management (4317110102A) Dc) Parameter (4317110103B) Dd) HMI setup (4317110104EF) De) IO-list (4317110105G) Df) Modbus RTU protocol (4317110107H) Dg) FMEA (4317110109A) E) DM4 Technical documentation Part 2 (general part) Ea) Alarm handling (4189232113B) Eb) Commissioning Guide (4189232127B) Ec) Common Generator Set Protection (4189232118B) Ed) General Introduction (4189232111B) Ee) General Menu System (4189232115B) Ef) Generator set control (4189232117B) Eg) Internal System Supervision (4189232114A) Eh) Power Management Unit (4189232116B) Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 4 of 6

Ei) Service Guide (4189232123B) Ej) Shore Connection (4189232120B) Ek) Technical Specifications (4189232129C) El) Tie Breaker (4189232121B) Em) Installation Instruction (4189232125D) F) DM4 FAT DNV witness test report - Protection (dated 070328) G) DM4 FAT DNV witness test report - PMS (dated 070328) H) Tested SW modules at DNV witness test (dated 070808) Environmental Test report IPA No.: 0207 dated 20060804. New documents in connection with inclusion of PCM 4-5 module in 2014: DNV GL Drawing No Rev. Title No 9 PA0324-04 DM 4 update 4-5 differences JST20140512A 10 4189230294 C Delomatic 4, DM-4 Marine & Offshore Data sheet (11 pages) 16 IPA0324-04 part 2 of 2 Product Documentation (compilation of data sheets, leaflets, etc.) 22 4157200479 J PCM 4.5 board schematics, IPA0324-04 Technical documentation 23 9A LR witness EUT 3102 PCM4.5 Vibration Test 24 14A LR witness EUT 3105 PCM4.5 Insulation test 28 6A LR witness EUT 3105 PCM4.5 Dampheat test 29 6B LR witness EUT 3104 PCM4.5 Slow transients - Surge 33 02A DNV GL witness EUT3237 PCM4.5 performance 34 02A DNV GL witness EUT3238 PCM4.5 performance 35 4A DNV GL witness EUT3237 PCM4.5 Dryheat Test 36 5B DNV GL witness EUT3238 PCM4.5 Electrostatic Discharge 37 13B DNV GL witness EUT3238 PCM4.5 Voltage Variations 38 15B DNV GL witness EUT3238 PCM4.5 Voltage Interruptions 39 16B DNV GL witness EUT3238 PCM4.5 Low-frequency Interference TA assessment report by DNV GL Aalborg dated 2016-11-14 Tests carried out Applicable tests according to Certification Notes 2.4, May 1995. Functional Type Tests on a representative 4 generator / single bustie breaker system at DEIF s test bench during 2007.03.27-28. Marking of product Each module shall be externally marked to enable identification in accordance with the documentation and be marked with the manufacturer s name. Periodical assessment The scope of the periodical assessment is to verify that the conditions stipulated for the type are complied with, and that no alterations are made to the product design or choice of systems, software versions, components and/or materials. The main elements of the assessment are: Ensure that type approved documentation is available Inspection of factory samples, selected at random from the production line (where practicable) Review of production and inspection routines, including test records from product sample tests and control routines Ensuring that systems, software versions, components and/or materials used comply with type approved documents and/or referenced system, software, component and material specifications Review of possible changes in design of systems, software versions, components, materials and/or performance, and make sure that such changes do not affect the type approval given Ensuring traceability between manufacturer s product type marking and the type approval certificate Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 5 of 6

Periodical assessment is to be performed at least every second year and at renewal of this certificate. END OF CERTIFICATE Form code: TA 1411a Revision: 2015-05 www.dnvgl.com Page 6 of 6