Theoretical analysis of low GWP mixture R600a/ R1234ze as a possible alternative to R600a in domestic refrigerators

Similar documents
Study of R161 Refrigerant for Residential Airconditioning

Refrigeration Cycle And Compressor Performance For Various Low GWP Refrigerants

ASSESSMENT OF R430A REFRIGERANT AS A POSSIBLE SUBSTITUTE TO R134A REFRIGERANT IN LARGE CAPACITY FREEZER

EVALUATION OF REFRIGERANT R290 AS A REPLACEMENT TO R22

Available online at ScienceDirect. Energy Procedia 109 (2017 ) 56 63

DEEPAK PALIWAL, S.P.S.RAJPUT

Part load performance analysis of vapour compression refrigeration system with hydrocarbon refrigerants

Low GWP Refrigerants for Air Conditioning Applications

Comparative assessment for drop in replacement of R134a in domestic refrigerator.

Experimental Research On Gas Injection High Temperature Heat Pump With An Economizer

Subscripts 1-4 States of the given system Comp Compressor Cond Condenser E Evaporator vol Volumetric G Gas L Liquid

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

Effects of evaporator load on vapour compression refrigeration system using ecofriendly hydrocarbon refrigerants with sub cooling

NUMERICAL SIMULATION OF VAPOUR COMPRESSION REFRIGERATION SYSTEM USING REFRIGERANT R152A, R404A AND R600A

CHAPTER 1 INTRODUCTION

Low Global Warming Refrigerants For Commercial Refrigeration Systems

EXPERIMENTAL INVESTIGATIONS ON AUTOMOBILE AIR CONDITIONERS WORKING WITH R134a AND R290/R600a AS AN ALTERNATIVE

International Research Journal of Engineering and Technology (IRJET) e-issn: Volume: 04 Issue: 05 May p-issn:

A Theoretical investigation on HC Mixtures as Possible Alternatives to R134a in Vapor Compression Refrigeration

Study of Performance of Binary Mixture of R134a and R161 as a Substitution of R134a in a Domestic Refrigerator

SIMULATION OF POTENTIAL REFRIGERANTS FOR RETROFIT REPLACEMENT

ADVANCES in NATURAL and APPLIED SCIENCES

Role of Nano-technology for improving of thermal performances of vapour compression refrigeration system (VCRS): An Overview

Performance Evaluation of Heat pump System using R32 and HFO-mixed Refrigerant in High Ambient Temperature.

WORK STUDY ON LOW TEMPERATURE (CASCADE) REFRIGERATION SYSTEM

Theoretical performance evaluation of R134a and its low GWP Hydrocarbon alternatives in Domestic Refrigerator

Performance Characteristics and Optimization of a Dual-Loop Cycle for a Domestic Refrigerator- Freezer

Alternative Refrigerants For Household Refrigerators

IJISET - International Journal of Innovative Science, Engineering & Technology, Vol. 2 Issue 12, December

THEORETICAL INVESTIGATION OF THE PERFORMANCE OF SOME ENVIRONMENT-FRIENDLY REFRIGERANTS IN A SUB-COOLING HEAT EXCHANGER REFRIGERATION SYSTEM

Lower GWP Refrigerants Compared to R404A for Economizer Style Compressors

Australian Journal of Basic and Applied Sciences. Investigation of New Eco Friendly Refrigerant Mixture Alternative to R134a in Domestic Refrigerator

Volume 6, Issue 3(2018) ISSN International Journal of Advance Research and Innovation

A Comparison Between Refrigerants Used In Air Conditioning

Experimental study of Hydrocarbon Refrigerant Mixture R290/R600a as an alternative to Refrigerant R134a used in a Domestic Refrigerator

Design of Divided Condensers for Desiccant Wheel-Assisted Separate Sensible and Latent Cooling AC Systems

Environment Protection Engineering

Effects of Flash and Vapor Injection on the Air-to- Air Heat Pump System

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Control Method Of Circulating Refrigerant Amount For Heat Pump System

A RECENT REVIEW OF REFRIGERANT R-1234YF AND R-1234ZE (E)

Performance Evaluation of R290 as Substitution to R22 & Mixture of Them in Vapour Compression Refrigeration System

Optimization of Capillary Tube Parameters in Vapour Compression System using Environmentally Friendly Refrigerant R1234yf

The Circulation Composition Characteristic of the Zeotropic Mixture R1234ze(E)/R32 in a Heat Pump Cycle

Performance Measurement of R32 Vapor Injection Heat Pump System

Low GWP Refrigerants for Air Conditioning and Chiller Applications

Chapter 10. Refrigeration and Heat Pump Systems

Development of a Novel Structure Rotary Compressor for Separate Sensible and Latent Cooling Air-Conditioning System

Assessment of LPG as a possible alternative to R-12 in domestic refrigerators

TYPICAL INITIAL OUTPUT OF A CO 2 HEAT PUMP

Thermodynamic analysis of air cycle refrigeration system for Chinese train air conditioning

Assessment of Alternatives to Refrigerant R134a in Automotive Air Conditioning System

Performance Evaluation of Eco- Friendly Alternate Refrigerants for VCRS

R32 Compressor for Air conditioning and Refrigeration applications in China

Thermodynamic Analysis of Cascade Refrigeration System Using R12-R13, R290-R23 and R404A-R23

Experimental Study on Match for Indoor and Outdoor Heat Exchanger of Residential Airconditioner

IJESRT. (I2OR), Publication Impact Factor: (ISRA), Journal Impact Factor: 2.114

CHAPTER 1 INTRODUCTION

International Engineering Research Journal (IERJ) Special Issue Page , June 2016, ISSN

PERFORMANCE OF DEEP FREEZER BY USING HYDROCARBON BLENDS AS REFRIGERANTS

Development of R744 Two Stage Compressor for Commercial Heat Pump Water Heater

Thermodynamic Cycle Analysis of Mobile Air Conditioning System Using HFO-1234yf as an Alternative Replacement of HFC-134a

AN EXPERIMENTAL STUDY OF A REFRIGERATING PLANT WHEN REPLACING R22 WITH HFCs REFRIGERANTS

An Investigation Into The Influence Of Improved Refrigeration Cycle And Refrigerants On An Energy Efficient Domestic Refrigerator

Evaluation of HCFC Alternative Refrigerants

Comparative Performance Analysis of Domestic Refrigerator using R12, R134a and R600a Refrigerants

Experimental Evaluation of Refrigerant Mixtures as Substitutes for HFC134a

International Journal of Research in Engineering and Innovation Vol-2, Issue-2 (2018),

Volume 2, Issue 1 (2014) ISSN International Journal of Advance Research and Innovation

Introduction of Transcritical Refrigeration Cycle Utilizing CO2 as Working Fluid

Drop-in Testing of Next-Generation R134a Alternates in a Commercial Bottle Cooler/Freezer

Performance Enhancement of Refrigeration Cycle by Employing a Heat Exchanger

Theoretical and Experimental Analysis of the Superheating in Heat Pump Compressors. * Corresponding Author ABSTRACT 1.

Department of MCE, Islamic University of Technology 2. Abstract

Performance Study of a Water-to-Water Heat Pump Using Non-azeotropic Refrigerant Mixtures R407C

Evaluation and Optimization of System Performance using HFO-mix Refrigerants for VRF and Mini-split Air-Conditioner

Performance of an Improved Household Refrigerator/Freezer

Effect of capillary diameter on the power consumption of VCRS using different refrigerants

Main Anthropogenic Sources of Greenhouse Gases Refrigerants

*Corresponding author;

Performance Investigation of Refrigerant Vapor- Injection Technique for Residential Heat Pump Systems

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

4th International Conference on Sensors, Measurement and Intelligent Materials (ICSMIM 2015)

EXPERIMENTAL STUDY ON R1234YF HEAT PUMP AT LOW AMBIENT TEMPERATURE AND COMPARISON WITH OTHER REFRIGERANTS

Behavior of R410A Low GWP Alternative Refrigerants DR-55, DR-5A, and R32 in the Components of a 4-RT RTU

HCFC-22 replacement with drop-in and retrofit HFC refrigerants in a two-stage refrigeration plant for low temperature

A COMPARATIVE STUDY FOR RETROFITTING OF R-12 VAPOUR COMPRESSION REFRIGERATION SYSTEM BY ECO- FRIENDLY REFRIGERANTS R-134A, R-413A, R-423A

Experimental Analysis Of Vapour Compression Refrigeration System With Superheating By Using R-134a, R-12, R-717 Refrigerant

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Performance analysis of a vapour compression refrigeration system with a diffuser for theeco-friendly refrigerants R-134a, R-600a and R-152a

Performance characteristics of low global warming potential R134a alternative refrigerants in ejector-expansion refrigeration system

JJMIE Jordan Journal of Mechanical and Industrial Engineering

η second law = Second law efficiency

Conceptual Design of a Better Heat Pump Compressor for Northern Climates

Analysis of Constant Pressure and Constant Area Mixing Ejector Expansion Refrigeration System using R-1270 as Refrigerant

Numerical Study on the Design of Microchannel Evaporators for Ejector Refrigeration Cycles

Experimental Investigation of a New High Temperature Heat Pump Using Water as Refrigerant for Industrial Heat Recovery

Performance and exergy analysis of vapour compression refrigeration system using various alternative of R134a.

R-404A Alternative with Low Compressor Discharge Temperature

Transcription:

Purdue University Purdue e-pubs International Refrigeration and Air Conditioning Conference School of Mechanical Engineering 2014 Theoretical analysis of low GWP mixture / R1234ze as a possible alternative to in domestic refrigerators Jinyou Qiu Institute of Refrigeration and Cryogenic Engineering, University of Shanghai for Science and Technology, Shanghai, China, junior51020@163.com Hua Zhang Institute of Refrigeration and Cryogenic Engineering, University of Shanghai for Science and Technology, Shanghai, China, zhanghua3000@163.com Zilong Wang Institute of Refrigeration and Cryogenic Engineering, University of Shanghai for Science and Technology, Shanghai, China, usst_wzl@163.com Zhigang Zhou Institute of Refrigeration and Cryogenic Engineering, University of Shanghai for Science and Technology, Shanghai, China, zhouzg@usst.edu.cn Follow this and additional works at: http://docs.lib.purdue.edu/iracc Qiu, Jinyou; Zhang, Hua; Wang, Zilong; and Zhou, Zhigang, "Theoretical analysis of low GWP mixture /R1234ze as a possible alternative to in domestic refrigerators" (2014). International Refrigeration and Air Conditioning Conference. Paper 1516. http://docs.lib.purdue.edu/iracc/1516 This document has been made available through Purdue e-pubs, a service of the Purdue University Libraries. Please contact epubs@purdue.edu for additional information. Complete proceedings may be acquired in print and on CD-ROM directly from the Ray W. Herrick Laboratories at https://engineering.purdue.edu/ Herrick/Events/orderlit.html

2515, Page 1 Theoretical analysis of low GWP mixture /R1234ze as a possible alternative to in domestic refrigerators Jinyou QIU, Hua ZHANG, Zilong WANG, Zhigang ZHOU (Institute of Refrigeration and Cryogenic Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China) ABSTRACT In this study, a thermodynamic analysis of and /R1234ze mixture at three compositions of 0%, 20% and 50% R1234ze is measured in a domestic refrigerator. The main purpose of this study is to theoretically verify the possibility of applying the mixture /R1234ze in large capacity refrigerator. The performance has been assessed for different condensing temperatures between 30 and 50 with constant -20 evaporating temperature.the performance of the refrigerator was compared in terms of volumetric cooling capacity, COP (coefficient of performance), compression ratio and compressor discharge temperature. The results show that the volumetric cooling capacity, COP, compressor power consumption and compressor discharge temperature of /R1234ze mixture are similar to those of pure,so that compressor can be used for /R1234ze mixture without any modifications. The amount charge of the mixture /R1234ze is slight lower than that of in the same equipment. Flammability decreases in /R1234ze mixtures with increasing fractions of R1234ze. This is one of desirable characteristic that can reduce risk of flammability and explosion in large capacity refrigerator system. 1. INTRODUCTION Domestic refrigerators are identified as major energy consuming domestic appliances in every household(r. Radermacher & Kim, 1996). Over the past decades, conventional refrigerants such as HCFCs and HFCs have been used extensively in domestic refrigerators fields owing to their well chemical and thermodynamic properties. However, the increasing attention to environmental problems such as global warming, ozone depletion and atmospheric pollution has led to a large number of studies related to the selection of environmentally friendly refrigerants as working fluids for domestic refrigerators in recent years. R134a is considered as an environmentally safe refrigerant and is essentially non-toxic(dietrich, 1993),but its GWP (global warming potential) effect is very high. The Kyoto Protocol of the United Nations Framework Convention on Climate Change (UNFCCC) asked for reduction in emission of six categories of greenhouse gases, including R134a, used as refrigerant in domestic refrigerators(tasi, 2005). Therefore, according to Kyoto protocol(protocol, 1997), the consumption of R134a must be seriously reduced. From the environmental, ecological and health points of view, it is urgent to find some better substitutes for HFC (hydro fluorocarbon) refrigerants(johnson, 1998). Recently, Mohanraj et al.(m. Mohanraj, C. Muraleedharan, & Jayaraj, 2011) have reviewed the developments of new refrigerant mixtures for vapor compression based refrigeration systems. They stated that hydrocarbon refrigerants are identified as long-term alternatives to phase out the existing halogenated refrigerants in the vapor compression based systems. Regarding the performance, hydrocarbon mixtures are found to be better substitutes for R12 and R134a in domestic refrigerators(m. Mohanraj, S. Jayaraj, & Muraleedharan, 2009). A survey conducted by Jose et al.(m.c. Jose, S. Jacobo, C. Daniel, & Jose, 2008) proved that certain hydrocarbons have excellent characteristics as refrigerants from a thermodynamic point of view. Furthermore, hydrocarbon as a refrigerant may be used in small systems like refrigerators and small freezers (with hydrocarbon charge lower than 150 g) provided that they incorporate a few special safety measures. Even though and its blends are widely used in domestic sector in Europe, their use in North America is not extensive yet (Bansal P., Vineyard E., & O., 2011). The reason is manufacturers fear of flammability and explosion hazards in domestic refrigerators (J.M., 2008). Nevertheless, is the most frequently used hydrocarbon refrigerant with more than 95% of market share in many countries (RTOC, 2006). In 2004, 33% of global domestic refrigerator production used pure isobutane or its blends. It should be noted that normal use of in refrigerators

Preasure/(MPa) Liquid density/(kg/m 3 ) 2515, Page 2 has not resulted in any accidents (P. Wennerstrom, 2006). In contrast, some accidents have been reported during manufacturing or in the retrofitted equipment using hydrocarbons (Colbourne D., Suen K., & T., 2003). has a higher density than air, and in case of leakage it spreads close to the floor; thus, the risk of flammability increases(clodic D. & W., 1996). On the other hand, lower refrigerant charge reduces explosion risk. Some solutions to overcome the flammability of hydrocarbon refrigerants were presented(a. Gigiel, 2004). Mixture refrigerants can have each advantages of individual. So, mixing with synthetic refrigerants, such as R1234ze, can reduce the risk of flammability and explosion. Focus on R1234ze, this refrigerant has a GWP of 4(Nielsen, O.J., & al., 2007). According to the investigation by Osafune K.(2012) and Koyama S.(2013), R1234ze is expected to be categorized as ASHRAE safety classification A2L, and most metals, plastics, and elastomers are stable in this refrigerant. As the global environment is progressively concerned, greenhouse warming has also become very important these days besides the ozone depletion issue. One of the ways to alleviate greenhouse warming is to adopt the mixtures with low GWP and develop high efficiency refrigeration devices. From this point of view, the hydrocarbons and new synthetic refrigerant R1234ze with zero ODP and lower GWP could be possible alternative working fluid that can meet this need. The intention of this study is to show the possibility of applying the chosen refrigerant mixture in relatively large amount of charge refrigerator. Through this study, we hope that it could provide some useful data for the promising development of such domestic refrigerators in the future. 2. CHARACTERISTICS OF AND R1234ze The properties of and R1234ze (such as vapor pressure, liquid density, latent heat, and suction specific volume) for wide range of temperatures (between 230 and 360K) are compared in Figs. 1. Fig. 1(a) depicts the variation of vapor pressure of and R1234ze against temperature. It was observed that both have approximately the same vapor pressure at lower temperatures. However, the vapor pressure of R1234ze was found to be a little higher than that of at higher temperatures from 330K to 360K. The liquid densities of R1234ze and are compared in Fig. 1(b). The liquid density of R1234ze was found to be twice as much than that of in the study range temperature, which will significantly reduce the refrigerant charge requirement. The variation of latent heat of two investigated refrigerants is shown in Fig. 1(c). It was observed that R1234ze is almost the half compared to. From this point of view, R1234ze is slightly disadvantageous compared with. But, this disadvantage could be compensated be the lower suction specific volume of R1234ze. Fig. 1(d) shows the variation of compressor suction specific volume of the refrigerants under study. The lower suction specific volume of R1234ze than that of indicates the need for a smaller compressor size for the same mass flow rate, and this property would compensate the lower enthalpy of vaporization of R1234ze than that of discussed earlier in Fig. 1(c). The other properties such as critical temperature, critical pressure, boiling point, molecular weight, ODP and GWP of R1234ze and are compared in Table 1. R1234ze has zero ODP with low GWP of 4. The critical temperature and critical pressure of R1234ze were found to be lower than those of. Computational analysis of the above said thermophysical properties have been done using REFPROP software version 9.0. 2.5 R1234ze 1400 R1234ze 2.0 1200 1.5 1000 1.0 800 0.5 600 0.0 400 240 260 280 300 320 340 360 T/(K) (a) 240 260 280 300 320 340 360 T/(K) (b)

Latent heat/(kj/kg) Specific volume/(m 3 /kg) 2515, Page 3 450 400 R1234ze 1.50 1.25 R1234ze 350 300 250 200 150 100 1.00 0.75 0.50 0.25 0.00 50 (c) (d) Fig. 1: Thermodynamic properties of R134a and R1234yf: (a) Variation of vapor pressure with temperature, (b) Variation of liquid density with temperature, (c) Variation of latent heat with temperature, (d)variation of specific volume with temperature Refrigerant Boiling point ( ) Table 1: Properties of and R1234ze Critical Critical Molecular temperature pressure weight(kg/kmol) ( ) (MPa) Ozone depletion potential Global warming potential 11.73 58.12 135 3.650 0 0 R1234ze -18.8 114.04 109.5 3.636 0 4 3. CYCLE PERFORMANCE ANALYSIS Fig. 2(a) shows a schematic diagram of a simple refrigerator cycle composed of an evaporator, condenser, compressor, capillary tube expansion device. As shown in Fig. 2(b), this refrigerator cycle consists of a nonisentropic compression process, an isobaric heat rejection process, an adiabatic expansion process, and an isobaric evaporation process. In the pressure enthalpy diagram, the process path 1-2-3-3-4-1 -1. In order to obtain meaningful results from the refrigerator, the thermodynamic performances of the cycle are evaluated based on thermodynamic cycle analysis method. Steady flow energy equation and mass balance equation have been employed in each individual process of the cycle. Also the following assumptions have been made to simplify the analysis: 1. Heat transfer with the ambient is negligible. 2. Compression process is adiabatic but non-isentropic. 3. Evaporation and condensation processes are non-isobaric but pressure drops are constant. 4. Throttling process is adiabatic. 5. Vapor is at saturated or superheated condition at the exit to the evaporator. The detailed characteristics of the cycle can be found as follows: Refrigerating capacity of evaporator per unit of mass: Volumetric heating capacity per unit of swept volume at the inlet of the compressor: Specific work of compressor: 240 260 280 300 320 340 360 T/(K) The isentropic efficiency of the compressor is defined as: The coefficient of performance of heat pump (COP): -0.25 240 260 280 300 320 340 360 T/(K) (2) (1) (3) (4) (5)

Discharge temperature π COP Volumetric cooling capacity/(kj/m 3 ) 2515, Page 4 2 lgp Subcooling Compressor 3 3' 2' 2s 2 Evaporator 4 1' Capillary tube expansion device 3' 1 Condenser (a) (b) Fig. 2: (a) A Schematic diagram of refrigerator cycle, (b) Pressure-enthalpy diagram of refrigerator cycle. Where h 1 is the enthalpy of the compressor inlet; h 2s is the enthalpy of the compressor outlet at the isentropic compression processes; h 2 is the enthalpy of the compressor outlet at the actual compression processes. In the following analysis, these calculations are accomplished by using REFPROP software version 9.0.(Lemmon, Huber, & McLinden, 2010). 4. RESULTS AND DISCUSSIONS The effects of the two parameters on the cycle performance are analytically investigated over a range of values. The performance has been assessed for different condensing temperatures between 30 and 50 with constant -20 evaporating temperature. In addition, the compressor is assumed to have an isentropic efficiency η s = 0.85, which is constant and does not vary with the compression ratio in all cases. 3.1 Variation of Coefficient of performance (COP) The COP is compared in Fig. 3(a). The COP of mixtures was found to be close to for a wide range of condensing temperatures. The deviations for pure and mixtures are 0.3% and 0.6% at 40 condensing 4 1' Enthalpy(h) 1 Superheating 4.00 3.75 3.50 t evap. =-20 /R1234ze(0.8/0.2) t evap. =-20 /R1234ze(0.5/0.5) t evap. =-20 650 625 600 t evap. =-20 /R1234ze(0.8/0.2) t evap. =-20 /R1234ze(0.5/0.5) t evap. =-20 3.25 575 3.00 550 2.75 525 2.50 500 2.25 11 10 9 30 35 40 45 50 t cond. (a) t evap. =-20 /R1234ze(0.8/0.2) t evap. =-20 /R1234ze(0.5/0.5) t evap. =-20 475 75 70 30 35 40 45 50 t cond. (b) t evap. =-20 /R1234ze(0.8/0.2) t evap. =-20 /R1234ze(0.5/0.5) t evap. =-20 8 65 7 60 6 5 30 35 40 45 50 t cond. 30 35 40 45 50 t cond. (c) (d) Fig. 3: (a) Variation of pressure ratio with evaporator temperature, (b) Variation of volumetric cooling capacity with evaporator temperature, (c) Variation of COP with evaporator temperature, (d) Variation of compressor discharge temperature with evaporator temperature. 55

COP Discharge temperature 2515, Page 5 temperature, respectively. And the deviations are found to be small with condensing temperature decreases. The COP for both and mixtures decrease by about 35.1%,34.7% and 33.9% with an increase in condensing temperature from 30 to 50, respectively. 3.2 Variation of volumetric cooling capacity (VCC) VCC is the major factor considered for choosing the alternative, which influences the size of the compressors. The variation of VCC at different operating temperatures is illustrated in Fig. 3(b). VCC of mixtures were found to be slightly large than that of R134a for a wide range of condensing temperatures. The maximum deviations in VCC are found to be 2.3% and 7.1%, respectively. Hence, the mixtures can be used as drop-in substitute without major modification in the existing systems. So, from this point of view, the size of the compressors can be smaller for using these mixtures. 3.3 Variation of pressure ratio For any refrigerants to be a suitable alternative for in a conventional refrigeration system, it must meet certain criteria. One of these criteria is the compression ratio. The pressure ratio of the refrigerant influences the volumetric efficiency of the compressor. Fig. 3(c) shows the pressure ratios as a function of condensing temperature.the pressure ratio of mixtures were observed to be slightly higher than that of by about 1.9% and 5.3% at 40 condensing temperature, respectively. Hence, the mixtures can be used as drop-in substitute without major modification in the existing systems. 3.4 Compressor discharge temperature The compressor discharge temperature is the major factor influencing the life of the refrigerant compressors. The higher compressor discharge temperature will affect the properties of lubricants. The comparison of compressor discharge temperature of and mixtures is depicted in Fig. 3(d). The compressor discharge temperatures of mixtures were found to be slightly higher than that of for a wide range of condensing temperatures. The compressor discharge temperature increases with condensing temperature rises for both and mixtures. And, the maximum of the temperature is within the safe level. 3.5 Degree of superheat Analyzing the influence of the superheat degree on the COP, Fig. 4(a), it can be observed that the value of the COP obtained using and mixtures both increases with the superheat degree rises. Fig.11, it can be seen that the COP obtained increases 5.6~5.9% with the average superheat degree rises 10 for both and mixtures. And the COP obtained using mixtures are more sensitive than that of with the superheat degree rises. So, from this point of view, the COP is improved more for mixtures than that of with the superheat degree rises. But, the compressor discharge temperature increases with the superheat degree rises for both and mixtures depicted in Fig. 4(b), which is due to the higher compressor suction temperature with the superheat degree rises. This fact influences the life of the refrigerant compressors and affects the properties of lubricants. But, the maximums are all within the safe value. 2.8 2.7 /R1234ze(0.8/0.2) /R1234ze(0.5/0.5) 90 80 70 /R1234ze(0.8/0.2) /R1234ze(0.5/0.5) 2.6 60 50 2.5 40 2.4 0 10 20 30 40 t sd 30 0 10 20 30 40 t sd (a) (b) Fig. 4: (a) Variation of COP with degree of superheat (t evap. =-25 ; t cond. =40 ), (b) Variation of Compressor discharge temperature with degree of superheat (t evap. =-25 ; t cond. =40 ).

2515, Page 6 5. CONCLUSIONS Thermodynamic performance assessment has been made for a domestic refrigerator working with pure and mixture of and R1234ze, and the following conclusions were made. VCC of the mixtures was found to be closer with. Hence, the mixtures can be used in domestic refrigerator without major modifications. The COP of the domestic refrigerator working with mixtures were found to be slightly lower than that of by 0.3% and 0.6% at 40 condensing temperature, respectively. And, the deviations are found to be smaller with the condensing temperature decreases. The flammability and explosion of the mixture /R1234ze decrease greatly compares with pure. So, the mixture /R1234ze can be charged to the large system at the same risk of flammability and explosion. NOMENCLATURE The nomenclature should be located at the end of the text using the following format: COP coefficient of performance P pressure (kpa) H specific enthalpy (kj kg -1 ) η s isentropic efficiency w specific work of compressor(kj kg -1 ) π pressure ratio q e refrigerating capacity per unit of mass (kj kg -1 ) q h heating capacity per unit of mass (kj kg -1 ) q hv heating capacity per unit of swept volume (kj m -3 ) t temperature ( ) v specific volume (m3 kg -1 ) Subscripts d compressor discharge e evaporator c condenser sd superheat degree evap. evaporating cond. condensing 1-4 state points of refrigerant REFERENCES A. Gigiel. (2004). Safety testing of domestic refrigerators using flammable refrigerants. Int. J. Refrigeration, 27, 621-628. Bansal P., Vineyard E., & O., Abdelaziz. (2011). Advances in household appliances- A review. Appl. Therm. Eng., 31, 3748-3760. Clodic D., & W., Cai. (1996). Tests and simulations of diffusion of various hydrocarbons in rooms from air conditioners and refrigerators. Paper presented at the In: IIF/IIR Conf. Applications for Natural Refrigerants, Aarhus, Denmark. Colbourne D., Suen K., & T., Ritter. (2003). A risk assessment model for hydrocarbon refrigerants. Proc. Inst. Refrigeration, 1-14. Dietrich, W. (1993). A positive outlook for the future. ASHRAE J., 35, 64-65. J.M., Calm. (2008). The next generation of refrigerants e historical review, considerations, and outlook. Int. J. Refrigeration, 31, 1123-1133. Johnson, E. (1998). Global warming from HFC. Environ. Impact Assess. Rev., 18, 485-492.

2515, Page 7 Koyama S., Higashi T., Miyara A., & R., Akasaka. (2013). Research and development of low-gwp refrigerants suitable for heat pump systems In: JSRAE Risk Assessment of Mildly Flammable Refrigerants-2012 Progress Report (pp. 29-34). Lemmon, Eric W., Huber, Marcia L., & McLinden, Mark O. (2010). NIST Reference Fluid Thermodynamic and Transport Properties(REFPROP) (Version 9.0). M. Mohanraj, C. Muraleedharan, & Jayaraj, S. (2011). A review on recent developments in new refrigerant mixtures for vapor compression-based refrigeration, air-conditioning and heat pump units. Int. J. Energy Res., 35(8), 647-669. M. Mohanraj, S. Jayaraj, & Muraleedharan, C. (2009). Environment friendly alternatives to halogenated refrigerantsda review. Int. Journal Greenhouse Gas Control, 3, 108-119. M.C. Jose, S. Jacobo, C. Daniel, & Jose, G. (2008). Review of standards for the use of hydrocarbon refrigerants in A/C, heat pump and refrigeration equipment. Int. J. Refrig., 31(4), 748-756. Nielsen, O.J., & al., et. (2007). Atmospheric chemistry of CF3CFCH2: Kinetics and mechanisms of gas-phase reactions with Cl atoms, OH radicals, and O3. Chemical Physics Letters, 439(1-3), 18-22. Osafune K., Nishiguchi Y., Okamoto S., Sakyu F., & S., Koyama. (2012). Development of low GWP refrigerants suitable for heat pump systems. Paper presented at the Int. Symp. New Refrigerants and Environmental Technology 2012, Kobe, Japan. P. Wennerstrom. (2006). HC in Domestic Refrigeration, Natural Refrigerant Heat Pumps. Paper presented at the Royal Inst. of Technol. (KTH), Energy Technol. Dept, Stockholm, Sweden. protocol, Kyoto. (1997). United Nations Framework Convention on Climate Change. Paper presented at the United Nations, New York, USA. R. Radermacher, & Kim, K. (1996). Domestic refrigerators: recent developments. Int. J.Refrig., 19, 61-69. RTOC. (2006). UNEP Report of the Refrigeration Air Conditioning and Heat Pumps Technical Options Committee. Tasi, W.T. (2005). An overview of environmental hazards and exposure and explosive risk of hydrofluorocarbon HFCs. Chemosphere, 61, 1539-1547. ACKNOWLEDGEMENT The authors acknowledge the support provided by Shanghai Leading Academic Discipline Project (No.S30503) and the Innovation Fund Project for Graduate Student of Shanghai (No.JWCXSL1401).