Heating Element. Building Technologies HVAC Products

Similar documents
RAR... Photocell Detectors. Building Technologies Division

Infrared Flame Detectors

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. The QRA4.U is for use with the following types of burner control:

Flame detector. Building Technologies Division Infrastructure & Cities Sector

LOA44.252A27. Oil Burner Control. Building Technologies HVAC Products

Infrared Flame Detectors

LGA... Gas Burner Controls. Building Technologies Division

QRA4.U. Flame Detector. Siemens Building Technologies HVAC Products

QRA10... QRA53... QRA55...

LFE50. UV Flame Safeguard. Building Technologies Division DETACTOGYR

Blue-flame Detectors

LGA... Gas Burner Controls. Siemens Building Technologies HVAC Products

Use. For 2-pipe fan coils

Flame Safeguards LFE10. Building Technologies HVAC Products

QRC1... Blue-flame Detectors. Siemens Building Technologies HVAC Products

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

C Note! LGI16... Burner Controls. Building Technologies

Frost Protection Thermostat

Flame Safeguards LFE10. Building Technologies HVAC Products

QAF63.2-J QAF63.6-J. Frost detectors. for use on the air side

QRA10... QRA53... QRA55...

QAF64.2-J QAF64.6-J. Frost detector. for use on the air side

Oil Burner Controls LOA3... Building Technologies HVAC Products

Thermal Reset Limit Thermostats Electromechanical TW according to DIN EN 14597

LGA... Gas Burner Controls. Siemens Building Technologies Landis & Staefa Division

QRA2... QRA10... QRA53... QRA55... Flame Detectors. Siemens Building Technologies HVAC Products

QAF63.2 QAF63.6. Frost sensors for use on the air side. Building Technologies HVAC Products

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies HVAC Products

Oil Burner Controls LMO24... LMO44...

Oil Burner Controls LMO24... LMO44...

QRA10... QRA53... QRA55...

for relative humidity and temperature

Control Thermostat / Thermal Reset Limit Thermostat Combination of electromechanical TR and TW

QXA2100. Condensation monitor QXA2101. Monitor to prevent damage caused by condensation on chilled ceilings and HVAC plants with AC/DC 24 V power.

Room Temperature Sensors

LFE50. UV Flame Safeguard. Siemens Building Technologies HVAC Products DETACTOGYR. Series 02

Oil Burner Controls LOA3... Building Technologies Division

UV Flame Supervision System

QRA10... QRA53... QRA55...

Electronic timeswitch

for relative humidity and temperature with calibration certificates

LOA2... LOA3... Oil Burner Controls. Siemens Building Technologies Landis & Staefa Division

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

for relative humidity and temperature

Burner Management System

Room Air Quality Sensors

Room thermostats with LCD RDD100..

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Q-Series Relative Humidity and Relative Humidity & Temperature Sensors for Critical Environments and Outdoor Air

RAB21 RAB21.1. For two-pipe fan coils

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Room Temperature Controller

Basic unit with integrated air-fuel ratio control for forced draft burners

Wireless room thermostat with LCD

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

Room Temperature Controllers

Burner Management System

Duct Temperature Sensors

RAA30 RAA30.16/GR RAA30.26/GR. Room Thermostat. Adjustable room thermostat for heating only or cooling only systems

Room Temperature Controller

1592P01. for liquids in piping DN

Room Temperature Controller

Gas cylinder scale Model GCS-1

Room air quality sensors

QPA63... CO 2 /VOC Sensors. Siemens Building Technologies HVAC Products

Semi flush-mount room thermostats

Room Temperature Sensor

QFM21... Duct sensors. Symaro. for relative humidity and temperature

Indoor Air Quality Controller

Room thermostat with independent DHW control

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

Immersion Temperature Controller

Use. In ventilating and air conditioning plants to enhance room comfort and to optimize energy consumption by providing demand-controlled ventilation.

Room thermostat with Auto Timer, Option External Input

District heating controller for two heating circuits and d.h.w. according to Siemens specifications:

LAE10 LFE10. Use. Series 02

Room thermostat with Auto Timer, Option External Input

Burner Management System

Duct Air Quality Sensors

Room Temperature. for 2-pipe fan coil units for compressors in DX type equipment

Room thermostat with Auto Timer, Option External Input

G a

Main Features. Functions. with automatic ignition and control functions for the heating and domestic hot water circuit

Natural Ventilation. e-stack A-Series Ventilation System for Buildings with Atria. Installation and Maintenance. Palletised

TCS5JBL & TCS5JBLA. Low-Voltage Top-Up Switch

Flush-mounted room thermostat

ISOMETER IR1575. Insulation monitoring device for unearthed AC/3(N)AC systems up to 480 V and DC systems up to 480 V

Product Data Sheet 4114 N/17HH-218. The engineer's choice

PRELIMINARY EDITION

Room temperature controller with large LCD. Non-programmable, for heating or cooling systems

Universal Dimmer N 528D01, 2 x 300VA, AC 230 V 5WG DB01

RVP331. Heating Controller for 2 heating circuits, d.h.w. and boiler. Building Technologies HVAC Products

panasonic.net/id/pidsx/global Gentle start-up switches in accordance with ergonomics Reduces load on hands and fingers

MBCE-110/230UV Flame Sensor Module

Use. Functions. Key function. Other functions

Basic Unit with integrated Fuel / Air Ratio Control for Forced Draft Burners LMV Building Technologies

Room Temperature Sensors

Basic unit with integrated fuel-air ratio control for forced draft burners LMV Building Technologies Division

Semi flush-mount room thermostat

Transcription:

7 923 Heating Element AGA63 Heating element for use with SKP... and SKL actuators. The AGA63 extends the field of use of actuators and makes them more reliable at low or significantly varying ambient temperatures. The AGA63 and this Data Sheet are intended for use by OEMs which integrate the SKP... / SKL actuators with the heating element in their products! Use The heating element is designed for use with SKP... or SKL actuators on gas-fired combustion plant. 20.04.2016 HVAC Products

Warning notes To avoid injury to persons, damage to property or the environment, the following warning notes should be observed! Do not to open, interfere with or modify the heating element! All activities (mounting, installation and service work, etc.) must be performed by qualified staff Before making any wiring changes in the connection area, completely isolate the heating element from the mains supply (all-polar disconnection) Ensure protection against electric shock hazard by providing adequate protection for the connection terminals Each time work has been carried out (mounting, installation, service work, etc.), check to ensure that wiring is in an orderly state Fall or shock can adversely affect the safety functions. Such heating elements must not be put into operation, even if they do not exhibit any damage Mounting notes Ensure that the relevant national regulations for electrical installations are complied with. for fitting to SKPx5 or SKL25 Tension spring 7923z05e/1005 The is to be secured to the SKPx5 or SKL25 by means of 2 tension springs. First, hook the open eye of the spring in the aluminium base between the black covers of the SKPx5 or SKL25 Then, hook the closed eye in the recess of the. To avoid the risk of injury due to slipping, use a pair of pliers when fitting the springs! Installation notes Live and neutral or protective earth conductors must not be interchanged The power supply should be fused with a fuse type 6,3 A IEC 60127-2/V For electrical connections, refer to «Function» 2/6

Commissioning notes The AGA63 features heating control and adopts different housing temperatures, depending on the ambient temperature. The lower the ambient temperature, the higher the housing temperatures since the heat output increases Standards and certificates Note! Only in connection with actuators! EAC Conformity mark (Eurasian Conformity mark) ISO 9001:2008 ISO 14001:2004 OHSAS 18001:2007 Disposal notes The heating element contains electrical and electronic components and must not be disposed of together with domestic waste. Local and currently valid legislation must be observed. Mechanical design The heating element is an autonomous functional unit operating on AC 230 V. It is supplied complete with a 3-core connecting cable of 1.3 m with ferrules. The AGA63 contains a thermal cutout (nonexchangeable) to ensure protection against overtemperatures. Type summary and ordering Heating element The heating element is suited for use with the following types of actuators: - SKP15... - SKP25... - SKL25 - SKP55... - SKP75... The heating element is supplied complete with 2 tension springs for fixing. 3/6

Technical data General element data Environmental conditions Mains voltage AC 220 V 15 %...AC 240 V +10 % Mains frequency 50...60 Hz ±10 % Power consumption max. 150 VA min. 5 VA On time 100 % Weight approx. 490 g Connecting cable 3 x 1 mm², flexible, «L, N, PE» Degree of protection IP 40 Storage DIN EN 60721-3-1 Climatic conditions class 1K3 Mechanical conditions class 1M2 Temperature range -10...+60 C Humidity < 95 % r.h. Transport DIN EN 60 721-3-2 Climatic conditions class 2K2 Mechanical conditions class 2M2 Temperature range -40...+60 C Humidity < 95 % r.h. Operation DIN EN 60 721-3-3 Climatic conditions class 3K3 Mechanical conditions class 3M3 Temperature range -20...+60 C Humidity < 95 % r.h. Condensation, formation of ice and ingress of water are not permitted! 4/6

Function The temperature sensor inside the black housing acquires the temperature of the element at the location where it is in thermal contact with the actuator, thus ensuring that the temperature is maintained at a constant level of 40...45 C. This is true for an ambient temperature range of 15...+30 C. If the ambient temperature exceeds 30 C, the heating element will be deactivated and the temperature of the actuator follows the ambient temperature with a differential of 15 K (e.g. «Tamb» 50 C, «TSKP» 65 C). If the ambient temperature falls below 15 C, the housing temperature of the actuator will be appropriately lower (e.g. «Tamb» -20 C, «TSKP» 35 C). If ambient temperatures are lower, the rubber diaphragm of the SKP2..., SKL25, SKP5... and SKP7... becomes stiffer, which may lead to unsatisfactory control performance. If the ambient temperature falls below -20 C, inadmissible gas pressure deviations can occur. Electrical connections: L AGA63... SKP... / SKL... L N SKP N PE 40...45 C PE 7923d01/1005 amp 5/6

Assembly Dimensions in mm SKPx5... / SKL25... SKPx5... 7923z06/0805 7923z07/1005 44 86 97 80 7923m04/0605 72 6/6 2016 Siemens AG Division, Berliner Ring 23, D-76437 Rastatt Subject to change!