Packaged Ammonia Chillers with Variable Frequency Drives powerpac

Similar documents
Ammonia Refrigeration & Scenario in Industrial Refrigeration. By Ramesh Paranjpey ASHRAE Fellow Life member

Natural Choice -- Ammonia

Midwest Industrial Initiative Webinar: Industrial Refrigeration

Chillers and Refrigerants. Purpose of Today s Presentation. Agenda. GLHN Architects & Engineers, Inc. APPA Institute Session 322 EU

Math. The latent heat of fusion for water is 144 BTU s Per Lb. The latent heat of vaporization for water is 970 Btu s per Lb.

Low Charge ADX Ammonia. Presented by: Bruce Nelson, President, Colmac Coil Manufacturing Rick Watters, Vice President, AMS Mechanical Systems

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

PRICE CHOPPER SARATOGA, NY. First cascade supermarket system in North America Installed and Started March of 2008

Ammonia. Background on ammonia as a refrigerant

Technical Development Program

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Campbell Soup Company Extends Use of CO2 Systems Into Their Operations

Safe Handling of Ammonia & Reporting Leaks. Andrew Keeley, Senior Project Professional

PowerPoint Presentation by: Associated Technical Authors. Publisher The Goodheart-Willcox Company, Inc. Tinley Park, Illinois

Refrigeration Cycles MOHAMMAD FAISAL HAIDER. Bangladesh University of Engineering and Technology

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Ammonia Refrigeration: What should you keep in mind?

Natural refrigerants - naturally efficient

Ammonia Supply Systems for SCR

Thermodynamics I. Refrigeration and Heat Pump Cycles

PACKAGED REFRIGERATION EQUIPMENT

Refrigeration and Air Conditioning

Section 1: Theory of Heat Unit 3: Refrigeration and Refrigerants

Chapter 11 REFRIGERATION CYCLES

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Method to test HVAC equipment at part load conditions

Exhibition Hall 1. Fachprogramm. Technical Programme

RS-70 is suitable as a direct replacement for R-22 in low, medium and high temperatures in a great number of applications:

FACT SHEET 6 Transport Refrigeration

Q. Which hydrocarbons can be used as a refrigerant? The following hydrocarbons can be used as a refrigerant in cooling & heating applications:

Paper No. : 04 Paper Title : Unit Operations in Food processing Module 11 : Principles of Refrigeration

Energy Use in Refrigeration Systems

Preventing False Alarms in Ammonia Gas Detection Systems

RSES SERVICE APPLICATION MANUAL TABLE OF CONTENTS AUGUST 2016

Chapter 11 REFRIGERATION CYCLES

Chapter 10. Refrigeration and Heat Pump Systems

Energy Efficiency Considerations in Refrigeration Systems

Current use of HFCs and HCFCs. Trends, alternatives and climate impact. YEREVAN, Armenia, May 18-19, International Institute of Refrigeration

A Comparison Between Refrigerants Used In Air Conditioning

Hydrocarbons as refrigerants

Natural Refrigerants: Future-proof Solutions for Today. eurammon End-Users Day 2011

Due to its low temperature glide about 1.5 approx. (75% less than R-407C and R-427A), it is suitable for a wide range of applications.

THE BIG FIVE NATURAL REFRIGERANTS IN DIFFERENT INDUSTRIAL APPLICATIONS. MAYEKAWA EUROPE S.A.,Leuvensesteenweg 605, 1930 Zaventem, Belgium

ABSTRACT. 2 CanmetENERGY

60 TON AIR-COOLED CHILLER. Call us today! (800) PA-ACCTR-60 GENERAL DIMENSIONS ELECTRICAL DATA 60 TON AIR-COOLED CHILLER FEATURES

Natural Refrigerants.

Dunham Bush Air Cooled Screw Chiller AFVX B 6SR Series

Air Conditioning and process cooling Energy Components at a Glance

Winter sports fun all year round, thanks to natural refrigerants

The lowest energy consumption when using R290 LBP fixed speed compressors in a plug in ice cream conservator

Fixed Ammonia Gas Detection. Why it's needed and what it can do for you.

ENERSAVE Hydrocarbon Scroll Water Cooled Chiller

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

REFRIGERATION CYCLE Principles of Mechanical Refrigeration Level 2: Cycle Analysis

Trailblazer air cooled scroll chillers

Presented By: John Dolan, P.E.

Session: HVAC 101 HVAC 101. Steve Sain Sain Engineering Associates, Inc. August 9, Rhode Island Convention Center Providence, Rhode Island

Material Safety Data Sheet

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

Natural Refrigerant Market Trends

Thermodynamics II Chapter 5 Refrigeration

Environmentally friendly refrigeration systems for industrial use

BETACURE 100 CO-REACTANT

RECORD SUBMITTAL COVER SHEET

a. CFCs. b. HCFCs. c. Pressurized nitrogen. d. Compressed dry air. 17. The state of the refrigerant leaving the condenser of a refrigeration system

Energy Saving & Eco-Friendly Refrigerant

Improving Cold Chain Competitiveness with Danfoss Energy Efficiency Solutions.

R717 ROMANIAN REFRIGERATION SYSTEMS ANALYSIS Professor Gratiela-Maria TARLEA, Ph.D

Presentation on HVAC: Heating Ventilation Air Conditioning

Product Data. Features/Benefits. 19XB Positive Pressure Storage System

NEW HARRIS TEETER STORE SHOWCASES FIRST HILL PHOENIX SECOND NATURE COMPACT CHILLER UNITS IN NORTH AMERICA

CO 2 Ice Bank Answer to the next requirements

PRESSURE-ENTHALPY CHARTS AND THEIR USE By: Dr. Ralph C. Downing E.I. du Pont de Nemours & Co., Inc. Freon Products Division

Guidance for Stationary Refrigeration & Air-Conditioning

The Electronic Newsletter of The Industrial Refrigeration Consortium Vol. 11 No. 1, 2011

AlfaNova the first fusion-bonded plate heat exchanger. A product brochure for AlfaNova within Industrial Refrigeration

Presentation to. IOSH Food and Drink Group. Danny McDougall Richard Perkin

Chapter 11 REFRIGERATION CYCLES. Department of Mechanical Engineering

The Essentials Of Working With R-410A

Energy Performance of Low Charge NH3 Systems in Practice. Stefan S. Jensen

COLD STORAGE WAREHOUSE, USING DIRECT EXPANSION AMMONIA REFRIGERANT Ray Clarke ISECO Consulting Services Pty Ltd

NABTEB Past Questions and Answers - Uploaded online

HEAT EXCHANGERS Maximize Thermal Efficiency with LaZerWeld Plate Heat Exchangers. For Industrial Refrigeration

Natural refrigerants: current developments and trends

WHITE PAPER. ANSI/AHRI Standard for Fan and Coil Evaporators - Benefits and Costs

APS Chiller Seminar. Don Brandt, CEM-AEE, BEAP-ASHRAE ASHRAE and IEEE Life Member 3/16/2017

APPA Institute for Facilities Management. Energy & Utilities Cooling Production (316) Purpose of Today s Presentation. Agenda

Use Of Ammonia for Air Conditioning Applications

Life Cycle Cost Of Selecting Chiller Equipment: Manufacturer s Viewpoint. Daryl Showalter ChillerApplications Manager McQuay International

INTRODUCTION. Special Applications of Package Air Conditioners. Instant Cooling Requirement in Wedding Ceremonies

General Guidance. The easiest way to establish the amount of refrigerant in the system is to use data supplied by the manufacturer:

Gas Fired Double-Effect Chiller-Heater CH-MG Series: 150 and 200 RT Cooling Capacities

CH2351 Chemical Engineering Thermodynamics II Unit V Refrigeration. Dr. M. Subramanian

B. A. T. Basic Appliance Training

CHAPTER 1 INTRODUCTION

Use of transcritical CO 2 in industrial applications

Falling Film Chiller. water down to 0,5 C

Midea VFD Centrifugal Chiller Technology

Macurco Gas Detection Products

Date: August 21, Proposal Number: G Engineer: Payment Terms: Net 30 Days

Transcription:

Packaged Ammonia Chillers with Variable Frequency Drives powerpac John Ansbro Director Marketing

Ammonia Refrigeration Background Frick ammonia compressor built in 1886. Installed at Gipps Brewery, Peoria, IL. Operated until 1946. 2

Ammonia as a Refrigerant Ammonia, The Original Refrigerant: Mechanical Refrigeration developed in 1800 s First practical refrigerating machine using vapor compression developed in 1834 Basic closed cycle refrigeration system has changed very little since then Early refrigerants included ammonia, sulfuric ether, sulfur dioxide, methyl chloride Only ammonia secured a lasting role. 3

Ammonia as a Refrigerant Ammonia is typically used for: Post harvest cooling of fruits & vegetables Cooling & freezing of meat, poultry, & fish Freezing of ice cream & process foods Cooling of beverages, wine & beer Refrigeration of dairy products Ice manufacturing 4

Advantages of Ammonia Ammonia is inexpensive, (mass basis) R-717 (NH3) R-22 R-507 R-404A R-134a < $1 / lb. $10 / lb. $12 / lb. $9 / lb. $10 / lb. Ammonia readily used for agriculture with stable costs Costs for all others expected to increase 5

Advantages of Ammonia Ammonia leaks are easy to detect/self alarming Pungent odor at levels less than 10 ppm Leaks are detected and fixed before major loss Readily absorbed in water Lighter than air, leaks will rise away from ground R-22, R-507, R-404A, & R-134a are odorless Small leaks difficult to detect Major refrigerant loss potential before leak found Heavier than air, displaces oxygen from ground up 6

Advantages of Ammonia Ammonia being a natural refrigerant is small part of the solution.. Ammonia s cycle efficiency is the real answer! 7

Advantages of Ammonia Ammonia has better cycle efficiencies Refrigerant Net Refrigerant Effect BTU/lb m Compressor Displacement cfm Coefficient of Performance Efficiency Penalty 507 47.28 3.427 4.18-13% 404A 48.98 3.494 4.21-12% 22 70.46 3.573 4.65-3% 134a 64.51 6.076 4.6-4% 717 474.20 3.450 4.77 0% Result is lower operating costs! Note 1 : Data based on 5 F evaporative, 86 F condensation, 0 F subcool, and 0 F superheat. Note 2 : The above information was obtained and presented in the 2001 Ashrae Fundamentals Handbook, section 19.8 table 7. 8

Advantages of Ammonia Coefficient of Performance for Refrigerants Percent Difference from Ammonia 2% 0% -2% -4% -6% -8% -10% -12% -14% -16% NH3 R-22 R-12 R-134a R-502 NH3 R-22 R-12 R-134a R-502-40 0 40 Evaporation Temperature (F) 9

Disadvantages of Ammonia Ammonia is not compatible with copper Special hermetic motors must be utilized Either steel/aluminum piping is required Advantages of enhanced heat transfer diminished 10

Disadvantages of Ammonia Low concentrations ruled toxic Short Term Exposure Limit 35-50 ppm However self alarming at 5 ppm 1500 ppm instant reaction to flee Considered flammable In narrow range of concentrations of 16-25% by volume of air in presence of open flames 11

Ammonia Exposure Table Exposure, ppm Effects 0-5 Smell hardly detectable. 5-20 Human nose starts to detect. 25 TLV-TWA (Threshold limit value time weighted average, 8h). 35 STEL (Short term exposure limit 15 min.) 150-200 Eyes affected to limited extent after about 1 min exposure. Breathing not affected. 500 IDLH (Immediately Dangerous to Life and Health, per NIOSH). 600 Eyes streaming in about 30 s exposure. 700 Tears to eyes in seconds. Still breathable. 1,000 Eyes streamed instantly and vision impaired, but not lost. Breathing intolerable to most participants. Skin irritation to most participants. 1,500 Instant reaction is to get out. Table 1: Ammonia Exposure: source, Cooling applications for ammonia refrigeration by W.F. Stoecker, University of Illinois at Urbana and Atmospheric emissions and control, Ammonia Plant Safety by D.P. Wallace. 12

Disadvantages of Ammonia Regulations OSHA requirement for PSM EPA requirements for RMP for systems with over a 10,000 lb R-717 charge Permitting in some states, long process California, New Jersey Some areas require R-717 safety relief headers be piped to dump tanks Added cost to the system 13

Government Regulations for Ammonia Under OSHA and USEPA chemical safety programs: Facilities with 10,000 lb s or more of ammonia must be registered. Synthetic refrigerants not covered. Under O.S.H.A. - must have Process Safety Management Program (PSM) Under U.S. EPA- must have Risk Management Program (RMP) 14

Trends Regarding Ammonia Use European chiller market heavily ammonia based. 90% of the chillers produced for the northern European market use R-717 Currently few US Domestic chillers make use of R-717 western European multi-national corporations employing their corporate natural refrigerant policy. 15

Trends Regarding Ammonia Use 16

Trends Regarding Ammonia Use 18

20

21

Ammonia Chiller: A chiller that utilizes ammonia as the refrigerant and consists of a compressor package, microprocessor, plate heat exchanger evaporator & condenser, oil cooler, surge drum, all assembled and wired in a factory controlled environment. 22

powerpac Advantages Compact design Small ammonia charge Evaporator and condenser in stainless steel Efficient oil return system Less welding Complete with control and monitoring system Flooded system with ammonia provides an efficient thermal solution while offering ideal operating economics 23

powerpac 24

Application / Advantages Processes that require a secondary brine Flexible capacity expansion with reduced refrigerant charge (Chillers 1 lbs. / ton of refrigeration) Containment of refrigerant to the chiller package (critical charge) Factory assembled / factory wired. Virtual freeze-proof heat exchanger 26

Application Opportunities Light Industrial applications: Utility cooling ( i.e. plastic injection mold cooling) Dairy: Carbonated Soft Drink: Bottling lines HVAC: Global multinational companies natural refrigerant policy ban the use of CFC s and HFC s 27

$ Price $ / TR 50 1000 Capacity (tons) 28

29

30

Heathrow Airport Terminal 5 31

32 500 Tons Cooling Capacity

33

34

Packaged Mounted Variable Speed Drive 35

Water Chiller VFD history Unit Mounted First VFD chillers -400 hp max -Floor mounted (big) -High cost -Poor Harmonics Unit Mounted -500 hp max -Lower cost -Good Harmonics -1000 hp max -Reduced size -Reduced Cost -Water Cooled Screw chiller w/vfd introduced US Energy Crisis -Improved efficiency -Adaptive mapping Today 1970 1980 1990 2000 36 Increased VFD chillers size -500 hp max -Floor Mounted (big) -High cost -Poor Harmonics Air Cooled Screw chiller w/vfd introduced Water Chillers -3000 hp -Up to 13.8 kv YORK receives EPA Climate Protection Award

2005 EPA Climate Protection Award Variable Speed Chillers York Variable Speed Chillers save 400,000 tons of CO2 emissions annually. That is the equivalent of: 78,500 passenger cars not driven for one year or 46,600 homes not powered by electricity for one year. 37

Ammonia Chiller Installation Food Processing Plant located in Indiana, USA Capacity: 5,800 TR (20,400kW) SST: 30ºF (-1.1ºC) SCT: 98ºF (36.7ºC) Chillers: 5 @ 1,000TR (3,516kW) 1 Dual PAC 800TR (2,813kW) Each outfitted with packaged mounted, liquid cooled, Variable Speed Drive VSD Savings*: 725,000 kw-hr per year 1,243,325 lbs. reduction in greenhouse gas emissions or 564 metric tons reduction in greenhouse gas emissions or or 75 equivalent number of single family homes powered in a year with energy savings 103 equivalent number of cars taken off the road in year with energy savings or 170 tons of carbon equivalent with energy savings *Source: U.S. EPA 38

Chiller Evaluation Method: IPLV / NPLV 39

ARI Standard 550 / 590 40

Recommendations for Ammonia Work with consultants, Design-Build contractors, and manufacturers with a demonstrated record of working with ammonia refrigeration. Understand the implications and requirements for the installation location Process Safety Management (PSM) Risk Management Program (RMP) Incorporate ammonia safety in your location s safety program www.iiar.og International Institute of Ammonia Refrigeration www.reta.org Refrigerating Engineers & Technicians Association www.eurammon.com European association for Industrial Refrigeration www.iifiir.org/en/ Visit installations that have ammonia systems operating. 42

Proprietary & Confidential Questions and discussion 43

Ammonia as a Refrigerant Ammonia is often used for: Turbine Inlet Air Cooling 45