Zone Control Panels. ZoZ one Product Catalog Page 3 ED3 SMZ4SW SMZAC SMZ3SW JTZHP

Similar documents
SmartZone TM System Manual

DIGI3U. Zoning Systems. Installation Guide. That s all we do. Three-Zone, Universal Controller for Gas/Electric or Heat Pump Applications

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

T-32-TS Touchscreen Thermostat. Installation Manual

Zoning System Design Manual

LZP-2 ZONE CONTROL PANEL

TZ-4 TotalZone Zone Control Panel

Safety & Installation Instructions

McQuay Suite Type N Top Mounted Hydronic Heat Incremental Packaged Terminal Air Conditioners C:

Detailed Installer Guide

Model number is located on back of thermostat.

Safety & Installation Instructions

Installer Guide. WARNING Important Safety Information. 1 Specifications

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

Safety & Installation Instructions

Detailed Installer Guide

SECTION SPECIFICATION FOR HI-VELOCITY FAN COIL SYSTEMS

FEATURES AND BENEFITS

Programmable Touchscreen Thermostats. Disconnect power before beginning installation.

LP #112 Effective 3/1/07

Installation & Operation Instructions

EnviroZone-4 & EnviroZone-2 Quick-Start Guide

PRODUCT PRODUCT CODE TECHNICAL INSTRUCTIONS PAGE

COMcheck Software Version Review Mechanical Compliance Certificate

THE WALL-MOUNT ONE TON AIR CONDITIONER GREEN REFRIGERANT R-410A. 10,800 Btuh 9.00 EER Right Side Control Panel. Engineered Features

Modular Heating & Ventilating Unit Model IGX-HV

Installation & Operation Instructions

Small Digital Thermostat Controller Temperature Control

Gas-Fired Indoor and Outdoor Duct Furnaces

Installer Guide. WARNING Important Safety Information. 1 Specifications

H32 Uni- Zone Model H32

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

Thermostats... loaded with features, designed for value!

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

THE WALL-MOUNT ONE TON AIR CONDITIONER. Green Refrigerant. 12,000 Btuh EER Right Side Control Panel. Engineered Features

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

Specifications and Performance

Safety & Installation Instructions

LP# 116 Effective 1/1/14

Submittal Data PERFORMANCE DATA CERTIFIED DIMENSION PRINTS CERTIFIED ROOF CURB DIMENSION PRINTS SERVICE OPTION DIMENSION PRINTS

6 Setting Your Program Schedule 7 Operating Your Thermostat 8 Additional Operation Features 9 Thermostat Maintenance

VERTICAL STACK INNKEEPER GUIDE SPECIFICATION CGC Hybrid Heat Pump System

Specifications and Performance

CONTROLS THERMOSTATS Bulletin No November 2001 Supersedes September 2001 INNOVATOR PROGRAMMABLE THERMOSTATS ENGINEERING DATA

Digi-Zone. Installation and Operating Instructions. Model MDP3. Controlling Your Comfort Room By Room

Safety & Installation Instructions

Installation and Setup Guide

Thermostats. Thermostats

Outside Air Requirements... SOLVED!

MACH N-407 Heat Pump Air-Cooled Chiller

SECTION PACKAGED ROOFTOP AIR CONDITIONING UNITS - CUSTOM

R11C R12C R21C R22C/H R23C/H R24C/H

Digi-Zone Model MDP3 Ver.04

Indirect Gas-Fired Make-Up Air

E4EB-xxx-H Series Downflow, Upflow Electric Furnaces

SECTION AIR HANDLING UNIT

Safety & Installation Instructions

HEALTHY HOME SYSTEM CONTROL Plus Model: HHSC+

A. American National Standards Institute (ANSI): Establishes requirements applicable to certifying direct gas-fired heaters.

THERMOSTATS 126. MECHANICAL THERMOSTATS 1C20 / 1C21 / 1C26 / 1E30 / 1E56 / 1F56... Wiring Diagrams / Configuration

Safety & Installation Instructions

Indicates incorrect room temperature. No second stage or AUX heating. Emergency heat does not turn on

Preface. Overview. The above illustration shows a typical three zone Aprilaire Zoned Comfort Control system.

HEATING & COOLING SUBMITTAL The DuraPac Series Unit 559F/579F180, 216, 240, , 18, 20, and 25 NOMINAL TONS

WARNING Important Safety Information

Direct Gas-Fired Make-Up Air

Model Smart Digital Humidistat

Submittal Data 558F SINGLE-PACKAGE ELECTRIC HEATING/ ELECTRIC COOLING UNITS NOMINAL TONS DESCRIPTION FEATURES

Installation Instructions

ELECTRIC POSITION for electric heat, then confirm with Fan Test below.

WHITE-RODGERS COMFORT-SET 90 SERIES

Advance Release September 2009

ECONOMIZER CONTROLLER ET-858

E3EH-xxx-H Series E3EB-xxx-H Series

WARNING Important Safety Information

CAH SERIES INSTALLATION & MAINTENANCE MODELS CAH CAH

HVAC 101. The Basics of Heating, Ventilation and Air Conditioning

For information on any of these products, please contact your heating and air conditioning contractor or feel free to write or call us.

E2 Series. Downflow, Upflow Electric Furnaces TECHNICAL SPECIFICATIONS. Features and Benefits

MODEL TSTAT THERMOSTATS THERMIDISTAT TM CONTROL ELECTRO-MECHANICAL THERMOSTATS FEATURES/BENEFITS NON-PROGRAMMABLE THERMOSTAT

WARNING Important Safety Information

E3EB-xxx-H Series Downflow, Upflow Electric Furnaces

H3/V3 Series Horizontal and Vertical Indoor Air Handling Units. Engineering Catalog

1.03 RELATED SECTIONS: The following sections contain requirements that relate to this section.

Comfort System T-21-P Touchscreen Thermostat Installation Manual

WARNING Important Safety Information

Table of Contents. Builder Series. Premier Series. 2

ZonexCommander. ZonexCommander(Plus) Installation and Applications Manual. Network All Your HVAC Equipment

SEQUENCE OF OPERATION FOR ALC CONTROL AIR SOURCE HEATPUMP RECIRCULATION AIR WITH ECONOMIZER

THE ULTIMATE ROOFTOP SOLUTION

Internal ridged board 1" x 1.5 foil face installation shall be installed on roof, walls and base of casing.

R22C/H Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort

General Description. Operation

CommStat 6. Controller for Redundant HVAC Systems PRODUCT DATA SHEET

MAC N-407 Air-Cooled Chiller

R21C Packaged Terminal Air Conditioner (PTAC) Specifications and Performance. The Right Fit for Comfort R21C. Straight Cooling Nominal Capacities

THERMOSTATS. 100-Series. 200-Series. 300-Series. 400-Series. 500-Series. Model Number Identification UHC TST 101 GE MS

about your house Assessing the Comfort and Safety of Your Home s Mechanical Systems

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

INSTALLATION INSTRUCTIONS WALL MOUNTED PACKAGE AIR CONDITIONERS WA121

Transcription:

Zone Control Panels ED3 ED Zone Panels The ED3 and ED4 are configurable microprocessor based control panels. They are suitable for use with gas/electric, oil, electric, conventional, and dual fuel heat pumps with two stages of cooling. DIP switches on each panel allow the contractor to program this panel to operate in virtually any application. The ED panels are protected by a built in circuit breaker and are compatible with almost any thermostat on the market. The ED4 can also be programmed for fresh air intake in accordance with local codes. ED4 SM MZ Zone Panels SMZAC SMZ4SW one s SMZ-SW Panels provide contractors with a simple, low-cost zoning system for 2, 3, or 4 zones. SMZ-SW Panels require the use of a switchable subbase (which must have separate B & O terminals) in zone 1 to act as the system s master switch for heat, cool, and fan functions. SMZ Panels are relay based systems, and are not sensitive to temperature. So, SMZ's can be mounted virtually anywhere. All SMZ Zone Systems are equipped with individual zone damper control switches. These switches will allow a zone damper to remain in either open or closed position when the system is at rest. By setting the switches, the installer or home owner can choose the position of his system s dampers; to inhibit or allow air flow when the system is in constant fan mode. SMZ3SW JTZ Zone Panels JTZHP This system introduces features unique to the needs of heat pump applications. one s JTZ-HP Panel is a low cost expandable zoning system for use with heat pumps. The JTZ-HP can control three or more zones on a single unit. The switchable thermostat subbase in Zone 1 acts as the selector switch for heat, cool, emergency heat and fan functions. When all zones are satisfied, all zone dampers will be open to allow air circulation. Moving the fan switch on the Zone 1 thermostat subbase to on will activate the fan to enhance air movement. one s JTZ-HP panel has Y1 and Y2 terminals to allow operation of heat pumps with 2 stage compressors and will operate changeover valves activated in either the heat or cool mode. ZoZ one Product Catalog Page 3

DamPers Multi-Blade Multi-Blade Spring Return Multi-Blade The one Multi-Blade damper for residential zoning systems has been engineered to include many features. Ribbed for strength and extruded from lightweight aluminum, the sleek frame profile provides maximum strength without excessive reduction of free area inside the ductwork. The extruded aluminum blades are mounted with friction minimizing nylon bushings to provide easy transition between opening and closing. The one Spring Return MultiBlade Dampers also feature damper blades designed to remain within the damper frame for easy insertion and an external side-mounted linkage for smooth and quiet operation. These Multi-Blade dampers are available in 74 stock sizes with a 24-volt spring return Mid-Torque motor or a Power Open/Power Closed motor. An optional Spring Return High Torque motor is also available. Spring Return one round dampers are made of galvanized steel with reinforcing beads for maximum durability and are crimped on one end for easy installation. dampers are available with different motor options: Power Open/Power Close, Mid Torque Spring Open/Power Close and High Torque Spring Open/ Power Close. The single blade design insures smooth operation and efficient sealing for maximum control of air flow. The round housing is suitable for use with flexible ducting or round sheet metal duct. Multi-Size Multi-Size Since each damper of this series is adjustable, the eight different sizes available will adjust to 30 of the most common duct size requirements. This, coupled with an extruded aluminum frame and formed aluminum blade (combining minimum weight with maximum strength) defines a damper of unsurpassed durability and versatility. Each damper easily adjusts to a minimum of three different sizes and includes a mid-torque motor that ensures reliable trouble free operation. Multi-Size Spring Return Retro Fit Dampers Retro Fit Damper one Product Catalog Page 4 one Retro Fit Dampers can be used to add a zoning system to existing 6'' round ductwork without the need to section, take down or redesign existing ductwork. Retro Fit Dampers feature a high strength molded mounting plate with gasketing as well as a blade with an integral blade seal to further minimize or eliminate leakage. one Retro Fit dampers are powered by a 24 volt spring open/power closed motor and can be linked together for tandem operation.

thermostats DT3 DT3 Digital Set Back Thermostat 5+1+1 programmable Battery powered Available terminals RC, RH, W, Y, G, B, O Use with control panels - SMZ, SMZ-AC, ED DT4 DT4 Digital Display Thermostat Non-programmable Battery powered Available terminals RC, RH, W, Y, G, B, O Use with control panels - SMZ, SMZ-AC, ED DTAC DTAC Universal Multi-Stage Auto Changeover Digital Set Back Thermostat 5+2 programmable 24 Volt or Battery powered System settings: Heat Off Cool Emer - Auto, Fan settings: On - Auto Available terminals R, C, E/W1, W2, Y1, Y2, G, B, O, L Use with control panels - SMZ, SMZ-AC, ED, JTZ-HP DT5 DT5 Heat Pump Digital Display Thermostat Non-programmable 24 Volt powered with battery back up System settings: Cool Off Heat - Emer, Fan settings: On - Auto Available terminals R, C, E, W2, Y, G, O/B, L Use with control panel JTZ-HP, ED (zone 1 only) DT7 DT7 Heat Pump Digital Display Thermostat System settings: Cool Off Heat - Emer, Fan settings: On - Auto 5+2 programmable 24 Volt powered with battery back up Available terminals R, C, E, W2, Y, G, O/B, L Use with control panel - JTZ-HP, ED (zone 1 only) DZSBT DZSBT Digital Set Back Thermostat 5+ +1+1 programmable 24 Volt or Battery powered Available terminals RC, RH, W, Y, G, B, O Use with control panels - SMZ, SMZ-AC, ED ZoZ one Product Catalog Page 5

thermostats (ContinueD) DT8 DT8 Multi Stage Digital Set Back Thermostat 5+1+1 programmable 24 Volt or Battery powered Available terminals R, C, Y1, Y2, W1, W2, G Use with control panels - SMZ-AC DT6 DT6 Multi Stage Digital Display Thermostat Non-programmable 24 Volt or Battery powered Available terminals R, C, Y1, Y2, W1, W2, G Use with control panels - SMZ-AC 3WT 3WT Three Wire SPDT Mechanical Thermostat Hermetically sealed, read switch construction No system settings or fan settings Available terminals R, W, Y Use with control panel SMZ (zone 2 and above) (Use with MSSB sub base for zone 1 on SMZ) MSSB MSSB Six Wire Sub Base for use with 3WT thermostat System settings: Heat Off - Cool, Fan settings: On - Auto Available terminals R, W, Y, G, B, O Use with control panels SMZ (with 3WT zone 1 only), SMZ-AC, ED SB1 SB1 Three Wire Sub Base for use with 3WT thermostat System settings: Heat Cool, No Fan settings Available terminals R, W, Y Not for use with control panels Use for damper control only DZOT DZOT Outdoor thermostat SPDT remote bulb thermostat for sensing temperature changes Available terminals R, W, B Use where activation initiated by outdoor temperature change required ZoZ one Product Catalog Page 6

accessories PT40 RR1 PT40 Plate Mounted Transformer The one PT40 Plate Mounted Transformer is a 120 volt input, 24 volt output, 40va rated step down transformer. The PT40 installs on a typical 4 x 4 electrical box and one transformer can operate up to 4 one dampers. RR1 Relay The one RR1 Relay is a 24 volt single pole, double throw, multi-purpose relay that is typically used for applications when isolation or protection of circuits is desired. When more than one relay is required, use DRP-2 Universal Relay Pack (35233). M4000 M4000 Batch Analyzer The M-4000 helps contractors and engineers make intelligent decisions on balancing and/or maintaining HVAC systems. It calculates CFM and BTU s by measuring and analyzing humid- temperature and air velocity. Custom designed solid state circuitry ensures high ity, accuracy. s C special Controls FPS OTS LAT OTS Outdoor Temperature Sensor For use with the ED3 and ED4 panels. The OTS is installed outdoors and out of direct sunlight. The OTS is used with dual fuel heat pump/gas furnace installations. LAT Supply Air Temperature Sensor For use with ED3 and ED4 panels. The LAT is installed in the plenum or supply air duct after the evaporator coil. LAT helps protect equipment from freeze up or high limit lock out. FPS Freeze Protection Sensor The one FPS Freeze Protection Sensor is a low cost control designed to be put on the suction line outside the evaporator coil. At 38º it will break the circuit to the compressor relay (Y) preventing freeze-up. At 51º it will make the compressor relay (Y) continue the cooling cycle. The FPS can be used with any of the one control systems. DDW MPS4 DS11 DZEC DS11 Remote Damper Switch The one DS11 Remote Damper Switch is a wall mounted switch for manually opening and closing standard one dampers. Generally used in special applications for ventilation control, it installs in a standard 2 x 4 electrical switch box. MPS4 Multi-Position Switch (formally FAS-4) The one MPS4 switch is a remote, wall-mounted switch for manual control of one 4 position dampers - models MPRD, MPMS and MPMB. Easy to install, this 4 position switch allows the dwelling occupant greater comfort and flexibility in controlling the volume of air entering into the space. Typically used for fresh air intake purposes, it installs in a standard 2 x 4 electrical switch box. DZEC Enthalpy Control The one DZEC Enthalpy Control senses temperature and humidity and closes a set of contacts at a user determined level. The DZEC is typically used with the one EC-1 and EC-2 Economizer Panels. DDW Pressure Relief Damper Weight/Arm The one DDW replacement arm & weight for one Pressure Relief Dampers can be used to add more weight to the Damper Arm for higher pressure settings. ZoZ one Product Catalog Page 7

special Controls (ContinueD) DZDBF DZDBF Duct Board Damper Frames The one DZDBF Duct Board Damper Frames allow easy mounting of standard one model MS and MB dampers into Duct Board without tools. It consists of two metal sleeves which clip onto the edge of a slot cut into the duct board. TDT1 TDT1 Time Delay Timer The one TDT1 Timer is a "delay on make" solid state device for energizing 2nd stage heating or cooling without the need of a 2 stage thermostat. The time setting is adjustable from 1 to 8 minutes. It operates with voltages from 19 to 240 AC. DRP-2 DRP-2 Universal Relay Pack The one DRP-2 Universal Relay Pack consists of two 24 volt 4PDT "plug-in relays mounted on a circuit board. The circuit board has convenient terminal strips to make wiring easy and it is mounted in a plastic enclosure for protection. The DRP-2 can be used in a variety of situations and applications where two or more isolation relays are needed. Pressure relief DamPers Rectangular Pressure Relief Rectangular and Pressure Relief Dampers one Pressure Relief Dampers are used to relieve excess air pressure created when less than all the zones of a duct system are calling. They do this in a simple and reliable fashion based on barometric/static pressure in the duct system. When pressure builds up in the duct system due to satisfied zones, the pressure opens the damper blade and bypasses to an unconditioned area or back to the return air duct. The pressure relief damper closes when the system is off or when all the zones are calling. one Pressure Relief Dampers are available in both rectangular and round configurations. Pressure Relief replacement motors RM13 SRHTM024 Duro Zone has a wide variety of replacement motors for all the dampers it manufactures. Most are low voltage (24 volt) activated, but some are also available as 110 volt units. Models such as spring return, power open/ power close, and high torque spring return are available. For help in determining your replacement motor needs, contact your Duro Dyne representative or the Duro Dyne Technical Support department. RMSR024 ZoZ one Product Catalog Page 8

ed Zone system Panel Kits PT40 LAT Kit prices do not include Dampers and Thermostats. ED3 JtZ and smz Zone system PaCKages ED microprocessor zone control panels are suitable for all 2,3 and 4 zone applications. The panels are configurable and can be used for conventional heatcool, heat pump, dual fuel heat pump, geothermal and even hydronic and oil systems. Kits include a 24 volt 40va transformer, a control panel, and a supply air temperature sensor. The ED4 is especially well suited for applications where building codes require fresh air intake. Kit prices do not include Dampers and Thermostats. JTZ and SMZ Zone Control Packages provide, in one convenient box, all the controls necessary to install a 2 or 3 zone system. Each box contains a control panel, a 24 volt 40va transformer, and the necessary thermostats for each zone. JTZ and SMZ Zone Control Packages come in several configurations to address most two and three zone situations for both conventional Heating/Cooling Systems and for Heat Pumps. indoor air Quality and economizers AQC AQC-1 Air Quality Control Center When tightly insulated homes have windows and doors shut, stale air is sealed in and fresh air is sealed out. Fresh air provides a healthier home and work environment. The key to eliminating moisture, bacteria, carbon monoxide and household odors is bringing fresh air indoors. The Dyna-Fresh Air Quality Control System brings outdoor air inside to make a more comfortable and healthy environment. The key component is a control panel which draws air into the home or workplace at pre-determined intervals with a 24 volt timer or manual override for continuous fresh air flow. The fresh air is drawn in through a motorized round damper. This fresh air is mixed with the indoor air already inside the heating / cooling system. The mixture is now circulated through the ductwork while stale air is vented out through an existing ventilation (such as a bathroom exhaust fan). EC1 EC2 EC-1 Economizer Control The EC-1 is used in conjunction with two Duro Zone zone dampers and an enthalpy control to create an economizer package for an air-conditioning system. At rest, (outside conditions not conducive for cooling), the return air damper will be open, the fresh air damper will be closed, and the compressor will function normally. When correct enthalpy conditions are attained, (humidity and temperature conducive for cooling), the EC-1 will close the return air damper and open the fresh air damper. At the same time the compressor will shut down, but the fan will continue to run, drawing fresh air from outside to satisfy the cooling demand. EC-2 Economizer Control The EC-2 is used in conjunction with two Duro Zone fresh air 4 position dampers and an enthalpy control to create an economizer package for an air-conditioning system. The EC-2 incorporates a 4 position rotary switch to allow mixing of the outside air with return air. At rest (humidity and temperature not conducive for cooling), the return air damper and fresh air damper will be in the position indicated on the switch and the compressor will function normally. When correct enthalpy conditions are attained, (outside conditions conducive for cooling), the return air damper and the fresh air damper will change positions. At the same time, the compressor will shut down, but the fan will continue to run, drawing fresh air from the outside to satisfy the cooling demand. ZoZ one Product Catalog Page 9