... Variante -4E Gas Fired Unit Heaters... ErP. ErP Lot 21 Seasonal Efficiency compliant

Similar documents
BENSON.... Variante3 Fired Unit Heaters...

... LCSA - LCSBD - LCSC Gas Fired Unit Heaters ...

BENSON AMBIRAD. ... Variante Gas Fired Unit Heaters ... HEATI NG AND VENTILATION S OLUTIONS

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

... RHeco. High Efficiency Condensing Unit Heaters... Low NO x. ErP. ErP Lot 21 Seasonal Efficiency and NOx compliant

CI/SfB X. RHeco Series CONDENSING GAS FIRED UNIT HEATERS

PREEVA EC Gas Fired Heating, Ventilation & Cooling Units

OUH Suspended Oil Unit Heater

OUH Oil Unit Heater Range Controlling your working environment. heating ventilation integrity

Heat Exchanger models

BENSON AMBIRAD. ... EnviroAir Gas Fired Heating, Ventilation & Cooling Units ... HEATI NG AND VENTILATION S OLUTIONS

OUH Suspended Oil Unit Heater Gas Oil Fired & Optional Kerosene

CI/SfB X. EnviroPak Series GAS FIRED HEATING, VENTILATION AND COOLING UNITS

VPC Gas Cabinet Heater Range

VPC Gas Cabinet Heater Range Architects of your environment. heating ventilation air conditioning

VPx. Power Vented Gas Cabinet Heater Nautral Gas & LPG Fired Options

... UDSA - UDSBD Gas fired unit heaters...

PREEVA air handling unit

All Heaters Part L2B Compliant. Technical Data External Oil and Gas Cabinet Heaters. For Models. EVD Vertical Ducted EHD Hortizontal Ducted

CP+ Gas & Oil Cabinet Heater Range

Heat Exchanger models

Brute Elite Hydronic Boilers Indoor 285, ,000 BTU/Hr. 95+% Thermal Efficiency

Gas-fired unit heaters for indoor installation

Brute Elite Volume Water Heaters Indoor 150, ,000 BTU/Hr. Up to 97% Thermal Efficiency

940ESO Tankless Water Heater

... Vision Radiant Tube Heating Systems ... ErP. ErP Lot 20 Seasonal Efficiency and NOx compliant

RHC GAS FIRED HEATING COILS

Knight & Charger Water Heaters

Superior. A Compact Floor Standing Gas Fired, High Efficiency Condensing Hot Water Boiler. Outputs 120, 160, 200, 240, 280 kw

FEATURES AND BENEFITS. Up to 109.8% part load efficiency

Room sealed circuit appliance sold without the terminal or the combustion air supply and exhausted gas ducts. TYPE C 63 TYPE B TYPE B 23

IMAX XTRA EL. 715kW FLOOR STANDING CONDENSING FEATURES AND BENEFITS

Gas-Fired Indoor and Outdoor Duct Furnaces

Model UDAP. Power Vented, Low Static Axial Fan Commercial/Industrial Unit Heaters DESCRIPTION STANDARD FEATURES OPTIONAL FEATURES - FACTORY INSTALLED

G34M Bulletin #69/ August 2003

LARGE CAPACITY HEATERS

FMH Range Hoods. Installation, Operation & Maintenance Instructions

Cabinet Heaters. Over 91.5% NET Efficient! Quality in Any Language TM. Ideal for industrial and commercial applications

Line Pressure ( w.c.) Gas Supply Min. Max. Pressure ( w.c.) Natural Gas Propane Gas

AMBIRAD.... Vision Radiant Tube Heating Systems...

TE Powrmaster Heater Range Controlling your working environment. heating ventilation integrity

BENSON VARIANTE 2 RANGE

P e l l e t S t o v e S P U R e P e R F o R M A N C e

Technology and design with Comfort and Energy Saving in mind. Instantaneous Gas Water Heater Series

HOT AIR GENERATOR WITH GAS BURNER NA11.45 A GGS. Installation Operation Commissioning Maintenance

OnePlus. Packaged Air Handling Units for Ducted Installations. Caring for the environment!

Sirius FS. Working towards a cleaner future

PSO Gas & Oil Cabinet Heater Range

EOLO MODULATING AND CONDENSING SUSPENDED GAS AIR HEATER HEATING COOLING GREEN ENERGY AIR HEATING TECHNOLOGY AND INNOVATION

OUH Suspended Oil Unit Heater Industrial & Commercial Heating Systems

Installation and Operating Manual Drying Cabinet

Heating, Air Conditioning, Ventilation. Отопление-Кондиционеры-Вентиляция. MTM 8-30 kw UNIVERSAL OIL HEATER OPERATING MANUAL

Calder. Steel Hot Water Boiler Suitable for Pressure Jet burners Oil, gas, LPG or dual fuel firing. Outputs kw. Calder Model

Winterwarm Agri UK. Winterwarm. Winterwarm heating solutions ... Winterwarm-quality. heating solutions

SIME FORMAT WALL HUNG BOILERS MODEL 34i AND MODEL 34e. cod A

ALL THE BENEFITS OF THE ALL COPPER HEAT EXCHANGER

Calder Plus. High Efficiency Steel Hot Water Boiler Suitable for Pressure Jet burners Gas or LPG firing. Outputs kw. Calder Plus Model

UNIT HEATER CATALOG. Form RZ-NA-C-UH (Version F)

CI/SfB X. Vision RADIANT TUBE HEATING SYSTEMS

Hamworthy. Dorchester DR-SA & DR-SE Fully Automatic and Permanent Pilot Direct Gas-Fired Storage Water Heaters. Exceeds Minimum Requirements

Elite. Unit Heaters. Installation and Commissioning Manual. Tubular Unit Heaters Elite Range

SGS Condensing High Efficiency Gas-Solar Water Heater

MODEL PVF INDIRECT GAS FIRED FURNACES FOR ENERGY RECOVERY UNITS Installation, Operation, and Maintenance Manual

Dryer for semi-commercial laundry applications

BENSON LINEAR RADIANT TUBE

Gas-Fired Power Vented Unit Heaters Propeller & Blower Models

BENSON VARIANTE 2 RANGE

Application instructions

RL/1 SERIES. One Stage Light Oil Burners FIRING RATES LIGHT OIL RL 34/1 MZ kw

RAYPAK HOT WATER & HEATING

CPx Gas & Oil Cabinet Heater Industrial & Commercial Heating Systems

NVx Suspended Gas Unit Heater Range

GAS UNIT HEATERS ARM RANGE

RHC & RHCE gas fired heating coils

RAYPAK HOT WATER & HEATING

Fundamentals of a gas fire New Zealand. August 2017

UNIT HEATER CATALOG. Form C-UH-0516 COMMERCIAL/INDUSTRIAL HEATERS RESIDENTIAL GARAGE HEATERS. FUEL Natural Gas Propane Fuel Oil

SUBMITTAL SCHEDULE & DATA

INSTALLATION & SERVICING MANUAL FOR BENSON VARIANTE² TUBULAR HEATER NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

PT Radiant Heater Range Controlling your working environment. heating ventilation integrity

CTU Unit Heaters. Installation, Commissioning, Operation & Service Manual. Model CTU 22 to 115. Quality in Any Language Copyright 2003 Roberts-Gordon

FSA, FOA, SEP & HED Series Unit Heaters and Duct Furnaces

T-CLASS GAS-FIRED UNIT HEATERS Separated Combustion - Direct Vent - Horizontal - 60 HZ. Thermal Efficiency - up to 82% Input - 40,000 to 300,000 Btuh

Air Replacement Systems

MODUCEL KW DOWNFLOW COOLING DRU DRU DATA ROOM UNITS

comfort and peace of mind

Warm Air Cabinet Heaters

GAS AIR HEATER RANGE

WHHR Midi & Midi Lite

C1210ESC Tankless Water Heater

OPTIMA RADIANT TUBE HEATING SYSTEMS. Operation, maintenance and servicing manual

Air Replacement Systems

Sirius WH. Working towards a cleaner future

Savile Plus. Steam Boiler. Suitable for Pressure Jet burners Oil, gas or dual fuel firing. Outputs kg/h

NVx Suspended Gas Unit Heater

BENSON GAS UNIT HEATERS

INSTALLATION & SERVICING MANUAL FOR HARRY TAYLOR VARIANTE² BI DIRECTIONAL NATURAL GAS (G20 I 2 H), PROPANE GAS (G31 I 3 P)

Aluminium range of condensing boilers. Works every time. Designed to meet carbon reduction targets. Lifetime service and support

Stainless steel range of condensing boilers. Designed to meet carbon reduction targets. Lifetime service and support. Outputs from 50kW to 660kW

STATIONARY HOT AIR HEATING SYSTEMS

Transcription:

... Variante -4 as ired Unit eaters... rp 2018 rp Lot 21 Seasonal fficiency compliant

Variante 4... as ired Unit eaters... The new Variante 4 builds on the technical excellence of the previous range to provide cost effective and robust heating for industrial and commercial buildings. Using wall or roof mountings, the heaters are available for either room sealed or conventional power flue applications. Specification abinet ormed from electro-zinc plated sheet steel and painted epoxy pebble grey (RL 7032) to give a robust and durable finish. Louvres painted yellow olive (RL 6014) (VR Only) eat xchanger Tubular four-pass serpentine arrangement manufactured as standard from alumised steel with stainless steel option. Model Range There are 2 Variante ranges: > > VR axial fan > > VR centrifugal The Variante gas fired units are available with eleven heat outputs for use on natural gas (20) as standard, but alternatively can be specified for use on propane (31). VR heaters are fitted with axial fans and discharge warm air through a front outlet fitted with both horizontal and vertical louvers. Units can be turned through 90 0 and blow vertically downwards when using the rear mounted suspension points (not 120 & 145 models). urner In-shot burner type with automatic spark ignition and full safety flame proving. Modulating control is supplied as standard. Power Venter lue an Variante 4 are fitted with a powerful venter fan that enables exhaust & combustion air to be run up to a maximum of 9m each. VR heaters are fitted with direct drive centrifugal fans and discharge warm air via a duct spigot on the outlet (optional louvers are available for free-blowing applications). or applications requiring a ducted connection on the inlet, an optional blower cabinet is available which can also be fitted with filters with filters and a single inlet damper if required. ll Variante models are fitted with a modulating burner as standard, which requires a 0 to 10v signal to operate.

Options > > Top flue outlet (VR) > > Stainless steel heat exchanger > > 30deg or 60deg downflow heads > > Wall brackets (VR) > > estratification thermostat > > lower cabinet* > > ilters* *VR models only as fired unit heaters... VR VR complete with duct spigot outlet VR complete with optional blower cabinet lectric Motors ll electric motors are rp compliant where necessary. fficiency ach heater within the Variante range has been designed and developed with fuel efficiency in mind with efficiencies exceeding the mandatory requirements of building regulations. uel eaters are supplied for use with natural gas (20) as standard, however propane (31) is available upon request. Sealed ombustion ircuit Variante heaters are factory fitted with a power flue venter that enables the heater to be operated in either room sealed or fan assisted flue mode. The flue fan is safety interlocked with the burner control system via a pressure differential sensor. single phase electrical supply is required to each unit except the VR60 which is three phase. This supply should not be switched off except for maintenance

as fired unit heaters......... Versatile lue Installation The balanced flue terminal provides both the combustion air inlet and flue outlet from a single building penetration. The terminals are ordered separately from the heaters to suit either a wall outlet or roof outlet. dditional flue and combustion air pipes may be added, up to a maximum of nine metres of flue pipe, plus nine metres of combustion air pipe. (This reduces by 1.5 metres for every 90 bend fitted). Installation Units may be suspended or alternatively mounted on a suitable non-combustible support. Integral suspension points complete with an M10 female thread are provided to each heater. alanced flue wall outlet (type 12) eliminates expensive roof opening and flashing alanced flue roof outlet (type 32) single phase electrical supply is required to each unit except the VR60 which is three phase. This supply should not be switched off except for maintenance. Min 300 mm Units must not be installed in atmospheres containing flammable or explosive vapours, combustible dust, halogenated hydrocarbons or chlorinated vapours. They are also unsuitable for areas where contaminants may affect electrical motors or connections. ombustion air through wall, flue outlet through the roof (52) Separate combustion air and flue pipes (type 12) for applications where wall thickness exceeds maximum length shown in flue dimension table eater positions and flue arrangements illustrate VR models and are indicative only. or heater and flue clearances please refer to the appliance installation and maintenance instructions. Optimised ontrol To complement the Variante units the versatile Smartom MZ control panel is available > > Self adapting optimum start and stop > > asy set overtime and holiday periods Remote burner reset facility > > Password protection to prevent unauthorised adjustment > > Simple user friendly programming > > Individual seven day programming > > ay, night and frost (5 ) temperature settings > > Three on/off periods per day > > ours run and service data logging > > attery back up in the event of mains failure > > Modulating burner control Smartom MZ panel allows up to 16 panels to be linked for centralised control

as fired unit heaters VR VR Technical ata Nominal heat output irflow Temperature rise kw m 3 /h K Model 12 20 30 35 45 50 60 75 100 120 145 12 1,100 30 22 2,000 31 26 2,300 33 36 3,200 33 as onnection Rc 1/2'' 3/4'' lectrical Supply V/ph/hz 230/240V 1N ~ 50z Total lectrical Rating W 530 360 250 370 370 540 760 760 850 1730 1730 Mounting height(s) m 2.5 3.0 4.0 4.0 4.0 4.0 5.0 5.0 5.0 6.0 6.0 45 4,300 31 51 5,000 30 61 5,200 34 73 7,300 29 95 8,000 29 119 10,800 32 Throw m 9.5 13 17 24 25 27 30 32 31 38 39 as onsumption Natural gas 20 Propane 31 m 3 /h kg/h 1.27 N 2.52 1.86 3.02 2.22 4.19 3.09 Maximum lue Run 9 Metres Noise level (1) d() 43 49 44 53 52 52 54 55 59 61 63 Net weight kg 59 59 64 94 99 114 114 126 184 242 279 5.19 3.82 5.82 4.29 6.98 5.15 8.38 6.17 10.95 8.24 13.80 10.17 137 11,400 35 15.77 11.62 as consumption & outputs based upon natural gas 20 having a calorific value of 10.5kWh/ m3 V & Propane 31 14.0kWh/kg V Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. ir Inlet lue Outlet (1) Sound pressure level measured at 5m from the unit with =160m2 and Q=2 nlet emale). lue Outlet as onnection 2 mm. 1. lectrical onnections. 2. Service Panel. 3. Suspension Points (M10 emale). Tolerance ll imensions ± 2 mm. ction VR imensions Model Ref 12 20 30 35 45 50 60 75 100 120 145 Unit Width 965 965 965 965 965 1298 1298 1298 1298 1750 1750 Unit eight 567 567 567 845 845 845 845 845 954 980 1 Unit epth 652 652 652 652 652 652 652 652 807 846 846 Overall epth 782 785 821 824 824 838 824 824 1022 1057 1057 Suspension Points Suspension entres M10 emale lue Outlet & ir Inlet dia 80 100 100 130 130 130 130 130 130 130 130 as connection Rc 1/2" 1/2" 1/2" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" 3/4" learances (minimum) Top Rear of an ottom Non ccess Side ccess Side 450 800 550 1365 770 1365 770

as fired unit heaters VR VR Technical ata Nominal eat Output irflow @ min static irflow @ max static Min static pressure Max static pressure as onsumption Natural as 20 Propane 31 lectrical Supply kw Pa Pa kg/h V/ph/z Model 20 30 45 60 75 100 22 2500 2250 50 200 2.52 1.86 26 4200 2700 50 300 3.02 2.22 230/240V 1N ~ 50z 45 5400 4000 61 73 95 50 200 250 350 300 5.19 3.82 6.98 5.15 400/415V 3P ~ 50z 8.38 6.17 11.19 8.24 230/240V 1N ~ 50z lower lectrical Rating W 300 600 1000 550 1800 1800 Total lectrical Rating W 453 753 1153 703 1953 1953 Noise level d() Net Weight kg 59 59 64 94 99 114 Min & max static pressure refers to external static pressure of ductwork (by others) as consumption & outputs based upon natural gas 20 having a calorific value of 10.5kWh/m3 V & Propane 31 14.0kWh/kg V Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. ir Inlet lue Outlet as onnection VR imensions Model 20 30 45 60 75 100 Unit Width 965 965 965 1298 1298 1298 Unit eight 567 567 845 845 845 954 Unit epth 652 652 652 652 652 807 Overall epth 1105 1105 1215 1215 1300 1455 Suspension Points M10 emale Suspension entres 550 lue Outlet & ir Inlet dia 100 100 1. lectrical 130 onnections 130 130 130 as onnection Rc 1/2" 1/2" 2. Service 3/4" Panel 3/4" 3/4" 3/4" uct Outlet Spigot learances (minimum) Top Rear of an ottom Non ccess Side ccess Side 307 533 372 533 3. Suspension Points (M10 emale) 607 515 607 (O): 533 Outher imensions 761 761 Tolerance ll imensions ± 2 mm 250 500 810 761

as fired unit heaters VR with abinet VR with abinet Technical ata Nominal eat Output irflow @ min static irflow @ max static kw Model 20 30 45 60 75 100 22 3100 2100 26 3900 2300 Max static pressure Pa 250 300 250 200 as onsumption Natural as 20 Propane 31 lectrical Supply kg/h V/ph/z 2.52 1.86 3.02 2.22 230/240V 1N ~ 50z 45 6200 5200 5.19 3.82 61 6500 5700 6.98 5.15 400/415V 3P ~ 50z 73 9600 7500 8.38 6.17 95 10500 8500 11.19 8.24 230/240V 1N ~ 50z lower lectrical Rating W 300 600 1000 550 1800 1800 Total lectrical Rating W 453 753 1153 703 1953 1953 Net Weight kg 59 59 64 94 99 114 Min & max static pressure refers to external static pressure of ductwork (by others) irflows & max static pressure quoted, exclude the use of optional filters and/or mixing dampers as consumption & outputs based upon natural gas 20 having a calorific value of 10.5kWh/ m3 V & Propane 31 14.0kWh/kg V Minimum gas inlet pressure is 17.5mbar for natural gas & 37mbar for Propane. Maximum inlet pressure is 50mbar. as onnection as onnection SIZ I J 20 1025 1677 404 82 502 232 965 123 30 1025 1677 404 82 502 232 965 123 45 1190 1842 504 171 802 82 965 123 * * 60 1375 2027 604 121 1002 149 1298 123 SIZ75 1375 2027 604 121 1002 149 1298 I 123 J ir Inlet lue Outlet as onnection 20100 1025 1375 1677 2182 404604 82175 502 1002 232149 965 1298 123128 550 * Optional inlet air damper 30 1025 1677 404 82 502 232 965 123 1. Suspension VR Points with (M10 abinet emale) imensions 45 1190 1842 504 171 802 82 965 123 2. lectrical onnections 3. as onnection 60 1375 2027 604 Model121 1002 149 1298 123 75 1375 2027 604 121 1002 149 1298 123 ir Inlet lue Outlet (od) Outher imensions 20 30 45 60 75 100 100 1375 2182 604 175 1002 149 1298 128 550 Tolerance ll imensions ± 2 mm Unit Width 965 965 965 1298 1298 1298 1. Suspension Points (M10 emale) 2. lectrical onnections Unit eight 567 567 845 845 845 954 3. as onnection abinet epth 1025 1025 1190 1375 1375 1375 (od) Outher imensions Tolerance ll imensions Overall epth ± 2 mm 1677 1677 1842 2027 2027 2182 Suspension Points Suspension entres learances (minimum) Top Rear of an ottom Non ccess Side ccess Side M10 emale lue Outlet & ir Inlet dia 100 100 130 130 130 130 as onnection Rc 1/2" 1/2" 3/4" ir Inlet 3/4" lue Outlet 3/4" 3/4" uct Outlet Spigot 404 404 504 604 604 604 502 1. Suspension Points 502 (M10 emale) 802 1002 1002 1002 2. lectrical onnections 3. as onnection (od) Outher imensions Tolerance ll imensions ± 2 mm 250 500 550 SIZ 20 1 30 1 45 1 60 1 75 1 100 1

NORTK LOL V (UK) LT ens Pool venue rierley ill West Midlands Y5 1Q United Kingdom /N/VR/007/1017 Tel: +44 (0)1384 489 250 ax: +44 (0)1384 489 707 reznorsales@nortek.com www.reznor.co.uk Registered in ngland No. 01390934 Registered Office The olmore uilding, olmore ircus Queensway irmingham 4 6 Nortek lobal V is a registered trademark of Nortek lobal V Limited. ecause of continuous product innovation, Nortek lobal V reserves the right to change product specification without due notice.