CR A-F-A-E-HQQE 3x400D 50 HZ

Similar documents
CR32-4 A-F-A-E-HQQE 3x400D 50 HZ

CR64-1 A-F-A-E-HQQE 3x400D 50 HZ

CR10-16 A-FJ-A-E-HQQE 3x400D 50 HZ

CR A-F-A-E-HQQE 3x400/ HZ

CRN A-F-G-E-HQQE 3x400D 50 HZ

CR A-F-A-V-HQQV 3x400D 50 HZ

CRN90-1 A-F-G-V-HQQV 3x400D 50 HZ

CR5-9 A-FGJ-A-E-HQQE 1x220/240 50HZ

CR A-F-A-E-HQQE 3x400/ HZ

CR20-07 A-F-A-E-HQQE 3x400/ HZ

TP /4-A-F-A-BQQE 400D 50HZ

SL S.S.N.51D

SL EX.4.51D

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with two or three CM, CMV or CR pumps. 50 Hz

GRUNDFOS DATA BOOKLET. Hydro Multi-S. Grundfos booster systems with 2 or 3 CM, CMV or CR pumps 50 Hz

Company name: Created by: Phone:

GRUNDFOS DATA BOOKLET MTB. Centrifugal machine tool pumps 50/60 Hz

GRUNDFOS DATA BOOKLET UPS2. Circulator pumps. 50/60 Hz

CombiBloc Close-coupled centrifugal pumps

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

GRUNDFOS DATA BOOKLET. Grundfos COMFORT. Circulator pumps. 50/60 Hz

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

Lenntech. Tel Fax bar. Multistage Pumps.

A Series. 60 Hz. Horizontal Multistage Centrifugal Pumps AHC/AHI, AHBI/AHBS ISO Vol. PIAH-18091

MARLOW PUMPS RECIRCULATION

2CP DATA SHEET. Horizontal Two Stage Centrifugal Pumps 2CP 32/210B 2CP 32/200B 2CP 32/200C

.2 Section Waste Management and Disposal..5 Section Motors, Drives and Guards for Mechanical Systems.

Inline Pumps LR/LMR & LRZ/LMZ, LER & LEZ. Lenntech. Tel Fax

KQ Series. Multistage Booster Pump System. Installation Manual. ISO 9001 Certified KQ200/400 KQ800

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

Chemical Pumps Vertical Chemical Pump Type TNP

GRUNDFOS END SUCTION PUMPS GRUNDFOS END SUCTION PUMPS

dualarm Vertical In-Line Pumps

Multistage Centrifugal Pumps with Shaft Sealing Type HZ / HZA / HZAR

KGP(X) Grinder Pumps HP Grinder Pump, 3 Phase (Class 1, Div. 1, Groups C & D Hazardous Location) Performance Curve.

SECTION STEAM CONDENSATE PUMPS

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

Transformer oil coolers BETA & CETA

CAP SERIES SEWAGE AND WASTE WATER PUMPS

GRUNDFOS DATA BOOKLET MAGNA3. Circulator pumps 60 Hz

ARBO Chemical pumps SealPro with mechanical seal. Product group 1.1

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

PAPANTONATOS. We supply clean water and remove waste water. P u m p s s e r v ic e & e n g i nee r in g. submersible pumps. s e w a g e p u m p s

Wilo IL Vertical Split-Coupled Inline Pumps

DNJ SERIES PUMPS END SUCTION CLOSE COUPLED

HTM Circulation Pumps acc. to DIN EN 733 Type NKX

IMMERSIBLE PUMPS FOR INDUSTRY

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

HORIZONTAL MULTISTAGE CENTRIFUGAL PUMP

our contribution for Sealless Magnetic Coupled, Heavy Duty Side-Channel Pumps environmental protection Type SCM PN40

CombiBloc. Close-coupled centrifugal pumps

TECHNICAL DESCRIPTION

CombiChem Centrifugal pumps. according to ISO 5199 and ISO 2858 / EN (DIN 24256)

CombiPrime Self-priming centrifugal pumps

K4RH(X) Solids-Handling Pumps

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

TYPE LF/LC/LCV END SUCTION PUMPS

K4RB(X) 4 Submersible, Recessed Impeller (Class 1, Div. 1, Groups C & D Hazardous Location)

GRUNDFOS DATA BOOKLET. Unilift CC, KP, AP. Submersible drainage and effluent pumps 50 Hz

SECTION STEAM CONDENSATE PUMPS

Combi Modular System. Standardised centrifugal pumps EN 733 ISO 2858 ISO 5199 API 610

Specially Designed Waste Water & Sewage Pumps

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

KEENER GRINDER PUMPS

Blockpumps. Vogel Series LSB. Lenntech. Tel Fax

Vogel Pumpen. Vogel Pumpen. Vogel - Blockpumps. Design LMN / LM

PRIUX HOME D. High-efficiency double circulating pumps Heating Air conditioning 50 Hz OPERATING RANGE APPLICATIONS BENEFITS

MODEL 652A MODEL 654A MODEL 652A MODEL 653A MODEL 651A AURORA. 650 Series SINGLE STAGE SOLIDS HANDLING PUMPS

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

GRUNDFOS PLUMBING & HVAC PRODUCTS

SIHI LPH-X - Liquid Ring Vacuum Pump One Stage

Volute Casing Pumps. Vogel Series LN/L ACCORDING TO EN 733 DE: +41 (0) FR: +41 (0)

A AD Oil burners fuel unit. deltapumps.com. DE A-AD_en_0709.pdf Page 1/1

Vertical Ring-section Pump WKTB. Type Series Booklet

UPZ PUMP POWER FOR TOP PERFORMANCE UNDER

DSV Model Air Cooled Self Contained Indoor Packaged Units 3-5 Tons Preliminary Application Data

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

Upompe Primeflo XP7 chemical self-priming centrifugal pumps

470 Series Stamped Stainless Steel Pumps

Excellent Engineering Solutions. Solids Handling Pumps. Recessed Vortex Impeller Pumps CLEAR LIQUID

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

Pumps Motors ISO 9001 Company

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

EVMSU - Vertical Multistage Pumps. Product Catalog

Patterson/AMT Inline Circulator Pump Refer to pump manual for General Operating and Safety Instructions.

FX5 Series Explosion-Proof Electric Air Heaters

STATION MODEL: KPCG21-24x48 PUMP MODEL: KEEN KPCG21 VOLTAGE: 230 PHASE: 1 TANK DIMENSIONS: 24 DIAMETER X 48 DEEP

Goulds LP3400 Series Low Pulse Fan Pumps

For calls outside the UK Telephone or Fax TETRA PAK PUMPS FREEPHONE: Centrifugal Pump Single Shaft Seal Type ALC-1

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

Series SR Compact Centrifugal Mag-Drive Pumps. WARRENDER, LTD. Process & OEM Pumps From Stock or Built-to-Spec

DUPLEX CONDENSATE TANK SYSTEM

Stainless steel centrifugal pumps

Advance Release September 2009

Oil burners fuel unit with solenoid valve

EHH SERIES DRAW THROUGH FAN COILS CFM

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

Transcription:

GRUNDFOS DATA BOOKLET CR64-2-2 A-F-A-E-HQQE 3x4D 5 HZ Grundfos Pump 96123528 Thank you for your interest in our products Please contact us for more information, or visit our website http://www.lenntech.com/grundfos/crfam/96123528/cr-64-2-2-a-f-a-e-hqqe.html info@lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89 BE > THINK > INNOVATE

Position Qty. Description 1 CR 64-2-2 A-F-A-E-HQQE Product No.: 96123528 Note! Product picture may differ from actual product Vertical, multistage centrifugal pump with suction and discharge ports on same the level (in-line) enabling installation in a horizontal one-pipe system. The pump head and base are in cast iron all other wetted parts are in stainless steel. A cartridge shaft seal ensures high reliability, safe handling and easy service and access. Power transmission is via a split coupling. Pipework connection is via DIN flanges. The pump is fitted with a 3-phase, fan-cooled asynchronous motor. Further product details The product carries the Grundfos Blueflux label. It represents the best from Grundfos within energy-efficient motors and frequency converters. Grundfos Blueflux solutions either meet or exceed legislative requirements such as the EuP IE3 grade. Steel, cast iron and aluminium components have an epoxy-based coating made in a cathodic electro-deposition (CED) process. CED is a high-quality dip-painting process where an electrical field around the products ensures deposition of paint particles as a thin, well-controlled layer on the surface. An integral part of the process is a pretreatment. The entire process consists of these elements: 1) Alkaline-based cleaning. 2) Zinc phosphating. 3) Cathodic electro-deposition. 4) Curing to a dry film thickness 18-22 my m. The colour code for the finished product is NCS 9/RAL 95. Pump A standard split coupling connects the pump and motor shaft. It is enclosed in the pump head/motor stool by means of two coupling guards. 1/9

The motor stool connects the pump head and motor. The pump head has a combined 1/2" priming plug and air vent screw. The pump is fitted with a balanced O-ring seal unit with rigid torque transmission system. This seal type is assembled in a cartridge unit which makes replacement safe and easy. Due to the balancing, this seal type is suitable for high-pressure applications. The cartridge construction also protects the pump shaft from possible wear from a dynamic O-ring between pump shaft and shaft seal. Primary seal: - Rotating seal ring material: Silicon carbide (SiC) - Stationary seat material: Silicon carbide (SiC) This material pairing is used where higher corrosion resistance is required. The high hardness of this material pairing offers good resistance against abrasive particles. Secondary seal material: EPDM (ethylene-propylene rubber) EPDM has excellent resistance to hot water. EPDM is not suitable for mineral oils. The shaft seal is retained in the pump head by a cover and screws. It can be replaced without removing the motor. The chambers and impellers are made of stainless steel sheet. The chambers are provided with a PTFE neck ring offering improved sealing and high efficiency. The impellers have smooth surface, and the shape of the blades ensure a high efficiency. The base is made of cast iron. Both the suction and the discharge side of the base have two pressure gauge tappings. The pump is secured to the foundation by four bolts through the base plate. The flanges are fastened to the base by means of locking rings. Motor The motor is a totally enclosed, fan-cooled motor with principal dimensions to IEC and DIN standards. The motor is flange-mounted with free-hole flange (FF). Motor mounting designation in accordance with IEC 634-7: IM B 5 (Code I) / IM 31 (Code II). Electrical tolerances comply with IEC 634. The motor efficiency is classified as IE3 in accordance with IEC 634-3. 2/9

Position Qty. Description The motor has thermistors (PTC sensors) in the windings in accordance with DIN 4481/DIN 4482. The protection reacts to both slow- and quick-rising temperatures, e.g. constant overload and stalled conditions. Thermal switches must be connected to an external control circuit in a way which ensures that the automatic reset cannot cause accidents. The motors must be connected to a motor-protective circuit breaker according to local regulations. The motor can be connected to a variable speed drive for adjustment of pump performance to any duty point. Grundfos CUE offers a range of variable speed drives. Please find more information in Win-/WebCAPS. Technical data Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Technical: Speed for pump data: Rated flow: Rated head: Shaft seal: Approvals on nameplate: Curve tolerance: Materials: Pump housing: Impeller: Water 243.. 393 K 293 K 998.2 kg/m³ 2919 rpm 64 m³/h 29.2 m HQQE CE,TR ISO 996:1999 Annex A Cast iron EN-JS15 ASTM 8-55-6 Stainless steel DIN W.-Nr. 1.431 AISI 34 Installation: Maximum ambient temperature: 333 K Max pressure at stated temp: 16 bar / 12 C 16 bar / -3 C Flange standard: DIN Pipe connection: DN 1 Pressure stage: PN 16 Flange size for motor: FF265 Electrical data: Motor type: 132SB IE Efficiency class: IE3 Number of poles: 2 Rated power - P2: 7.5 kw Power (P2) required by pump: 7.5 kw Mains frequency: 5 Hz Rated voltage: 3 x 38-415 D/66-69 Y V Rated current: 14,4-14,/8,3-8,1 A Starting current: 78-91 % Cos phi - power factor:,88-,82 Rated speed: 291-292 rpm 3/9

Position Qty. Description Efficiency: IE3 9,1% Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F Others: Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 117 kg Gross weight: 14 kg Shipping volume:.3 m3 4/9

96123528 CR 64-2-2 5 Hz H [m] CR 64-2-2, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] 4 35 3 25 1 2 8 15 6 1 4 5 2 5 1 15 2 25 3 35 4 45 5 55 6 65 7 75 8 85 P2 [kw] 8 Q [m³/h] NPSH [m] 16 7 14 6 12 5 1 4 8 3 6 2 4 1 2 5/9

Description Value Product name: CR 64-2-2 A-F-A-E-HQQE Product No: 96123528 EAN number: 57396697383 H [m] 4 35 CR 64-2-2, 5Hz Pumped liquid = Water Liquid temperature = 293 K Density = 998.2 kg/m³ eta [%] Technical: Speed for pump data: 2919 rpm Rated flow: 64 m³/h Rated head: 29.2 m Head max: 4.8 m Impellers: 2 Impeller reduc.: 2 Shaft seal: HQQE Approvals on nameplate: CE,TR Curve tolerance: ISO 996:1999 Annex A Pump type: CR 64 Stages: 2 Pump version: A Model: A 3 25 2 15 1 5 1 2 3 4 5 6 7 P2 [kw] 6 4 Q [m³/h] 1 8 6 4 2 NPSH [m] 15 1 Materials: Pump housing: Impeller: Material code: Code for rubber: Cast iron EN-JS15 ASTM 8-55-6 Stainless steel DIN W.-Nr. 1.431 AISI 34 A E 2 PN16 ø8 x 18 ø22 ø18 ø15 4 x ø14 ø1 45 266 331 5 Installation: Maximum ambient temperature: 333 K Max pressure at stated temp: 16 bar / 12 C 16 bar / -3 C Flange standard: DIN Connect code: F Pipe connection: DN 1 Pressure stage: PN 16 Flange size for motor: FF265 159 26 3 644 379 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 4482 14 19 248 365 Liquid: Pumped liquid: Liquid temperature range: Liquid temp: Density: Water 243.. 393 K 293 K 998.2 kg/m³ Electrical data: Motor type: 132SB IE Efficiency class: IE3 Number of poles: 2 Rated power - P2: 7.5 kw Power (P2) required by pump: 7.5 kw Mains frequency: 5 Hz Rated voltage: 3 x 38-415 D/66-69 Y V Rated current: 14,4-14,/8,3-8,1 A Starting current: 78-91 % Cos phi - power factor:,88-,82 Rated speed: 291-292 rpm Efficiency: IE3 9,1% Enclosure class (IEC 34-5): 55 (Protect. water jets/dust) Insulation class (IEC 85): F Motor protec: PTC Motor No: 85U17522 +T +T +T TO AMPLIFIER RELAY L1 L2 L3 +T +T +T TO AMPLIFIER RELAY L3 L2 L1 Others: 6/9

Description Value Label: Grundfos Blueflux Minimum efficiency index, MEI :.7 Net weight: 117 kg Gross weight: 14 kg Shipping volume:.3 m3 7/9

96123528 CR 64-2-2 5 Hz 26 159 644 379 3 PN16 ø8 x 18 ø15 ø18 14 ø22 19 248 365 45 ø1 266 331 4 x ø14 Note! All units are in [mm] unless others are stated. Disclaimer: This simplified dimensional drawing does not show all details. 8/9

96123528 CR 64-2-2 5 Hz +T +T +T TO AMPLIFIER RELAY +T TO AMPLIFIER RELAY L1 L2 L3 +T +T L1 L2 L3 IEC TP211 THERMALLY PROTECTED WHEN THE THERMISTORS ARE CONNECTED TO AMPLIFIER RELAY FOR CONTROL OF MAIN SUPPLY THERMISTORS PTC ACCORDING TO DIN 4482 Note! All units are in [mm] unless others are stated. 9/9

Disclaimer: The information about the Grundfos pump in this document may be outdated. Data may be subject to alterations without further notice. Please contact us to verify the data above is still accurate/up-to-date. All information is copyright Grundfos. info@lenntech.com www.lenntech.com tel. +31-15-261.9. fax. +31-15-261.62.89