Omniguard 4: Features

Similar documents
OMNIGUARD 4 DIFFERENTIAL PRESSURE RECORDER. Owner's Manual

OMNIGUARD II DIFFERENTIAL PRESSURE RECORDER

AS950 ALL-WEATHER REFRIGERATED SAMPLERS

UniGas Portable, Flue Gas Analysis Advanced Combustion Flue Gas Analyser

AS950 PORTABLE SAMPLERS

AS950 REFRIGERATED SAMPLERS

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

Microtherm Heat Stress WBGT

Operations Manual TS400. Test Station for G450/G460 Gas Detector

MicroTool. Not just a simple Measuring Instrument A complete Tool to support your daily activities FLUE GAS ANALYSERS

EasyLog Data Logger Series

User Manual. Humidity-Temperature Chart Recorder. Model RH520

Introduction. OM-THA2

The EN54 Part 2 & 4 Fire System

TLS-300 UST Monitoring and Leak Detection System

TS400. Operating Manual. Test Station for Microtector II Series (G450/G460)

Advanced Autoclave Controller with Recording + 4 Channel Mapping + Pressure Indication with PC Software & Printer Module

Mark 25 Ultrapure Water Conductivity Analyzer

SCM. Micro. Streaming Current Monitor. Analyzer. Sensor/Sampler with light shield removed. The Analyzer. Instrument Overview

Follett Performance Plus

ACT2-CS Convenience Store Controller

THA2 TEMPERATURE/ HUMIDITY/ DEWPOINT ALARM WITH LOGGING CAPABILITY. 99 Washington Street Melrose, MA Phone Toll Free

Nardalert S3 TM Non-Ionizing Radiation Monitor

Architectural and Engineering Specification for a. Flash / Flare

CONsOlIDATOR 4 & 8. MulTI- C h ANNEl CONTROllERs. ConsoliDator 4 Model PD940 ConsoliDator 4 Features. ConsoliDator 8 Features.

USER MANUAL USB Multi-Function Datalogger Model RHT35

Operations Manual TS400. Test Station for G450/G460 Gas Detector

i.c³ User Guide For Helmer i.series Ultra-Low Freezers A/A

USB Multi Function Dataloggers. RHT30 Humidity/Temperature Datalogger. TH30 Dual Temperature Datalogger

For the Safety of Your

Product Specifications

iminiplus PDF User Guide Version 2.0

Quick Alert Remote (QA216R)

Advanced Laundry Chemical Dosing System for Single and Multi-Washers

THX-DL Data Logger USER & INSTALLATION MANUAL V

EasyLog Data Logger Series

Model 1062 Environment Monitor

SC-F3G User Manual 1.0

OPTIMUM APPLIED SYSTEMS,

DGC-1000 DIGITAL GENSET CONTROLLER

Temperature + Humidity (%RH) Control & Recording System with 8 / 16 Channel Mapping. Touch Panel PPI

10A Micro-Ohmmeter Model 6250

MODUL-R FIRE ALARM CONTROL PANELS. MR-2900/MR-2920 Addressable Fire Alarm Control Panels MEA. Features. Description

Carbon Monoxide Transmitter

HRX Technical Manual. Version 1.2

portable gas analyser

Advanced Test Equipment Rentals ATEC (2832)

Product Specification

Specifications Minimum Typical Maximum Unit

Event Monitoring Device (EMD)

Remote Alarm Monitoring Alarm monitoring includes Global Remote Alarm Relay. Capabilities independent port can be used

EL-USB-CO300 Carbon Monoxide (CO) Data Logger with USB Interface

Instruction Sheet THERMOCOUPLE DATA LOGGER WITH LCD DISPLAY AND USB INTERFACE

The Kryos LN2 Liquid Level Control & Cryogenic Temperature Control

multi-gas detector Go the distance, and save Wear yellow. Work safe.

portable gas analyser

L CONNECTION NETWORK Commercial Controls

TrueCom. Building Communications Systems 5115-Series , Area of Rescue Communications System. Description

CASS9000 Standalone FingerPrint Door Access System. User Manual

VIBRA-series: VIBRA, VIBRA +

Emerson Inspire 1HDEZ Installation Instructions. Thermostat/Interface Equipment Control TROUBLESHOOTING

HOBO U14 Data Logger User Manual

MicroRay IR-100 NEW. Inspection MicroRay IR-100

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

LogTag TICT - is0 Tag

Modus Model DA General Eastern Low Differential Pressure Alarm Controller

Automatic Isokinetic Sampler ST5

Sirius Technologies, Inc.

All-In-One Wireless Security System V3.2 Programming Guide. Model # MG6130 / MG6160

THERMO BUTTON HYGRO BUTTON The smallest temperature and humidity loggers in the world!

Tempco PCT-3000 Series Temperature Control Console with Relay Output for Heating or Cooling Applications

Cold chain monitoring technologies. Facility monitoring

DATA SHEET CHEETAH XI 50 INTELLIGENT SUPPRESSION CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

DIESEL Engine Fire Pump Controllers Features

Duct and Rough Service Carbon Monoxide Sensor

FI6000 INSTRUCTION MANUAL. Thank you for choosing another quality product from Amperes Electronics. Fire Alarm Interface

SPM-4000-DC GUARDIAN INFINITY SPACE PRESSURIZATION MONITOR AND DUAL CONTROLLER

Tachometer/Hourmeter/Trip. Installation and Operation Manual

INSTALLATION INSTRUCTIONS

DATA SHEET CYBERCAT 254 INTELLIGENT FIRE ALARM CONTROL SYSTEM DESCRIPTION APPROVALS: SYSTEM OPERATION. Form No. D

SiteSentinel itouch Console

Operation Manual Fighter ProVision Software. Version: 0.0 Revision: 1

Falcon-II Next Generation, Air Quality Monitor CO2 & Temperature

OPERATION MANUAL MODEL LC2000 COPYRIGHT 2017 PNEUMERCATOR CO., INC EXPRESSWAY DRIVE NORTH HAUPPAUGE, NY 11788

Table of Contents SECTION PAGE

P Zone Expandable Hybrid Security System

TCA-9102 Series Surface Mount Temperature Controllers with High and Low Alarm

CONTROL PANEL INTERFACE ACTIVATE THE GENERATOR DISPLAY INTERFACE MENUS. Control Panel USING THE AUTO/OFF/MANUAL SWITCH

Section 9 System Operation

TrueAlarm Fire Alarm Systems

AS200 Wireless Alarm, Monitoring and Data Logging System USERS MANUAL

ModSync Sequencing System Installation & Operation Manual. For use with Fulton Steam Boilers.

MOVING FILTER AIR MONITOR ALPHA, BETA/GAMMA PARTICULATES

DS7400Xi Addressable Control/ Communicator

External Dimensions: B = 600 mm D = 630 mm H = 2000 mm. Internal Dimensions: B = 451 mm D = 430 mm H = 1598 mm

Analog Room Pressure Monitor RPC Series

TV2 Clean Room Monitor

MGC Dock User s Manual

Laboratory Deep Freeze Storage Cabinet TC 230 Air circulated

Alarm Tone Generator Model AG17

Transcription:

OMNIGUARD 4 The clear choice for monitoring and documenting Vacuum and Pressure in a containment area. Ideal for Asbestos, Lead and Mold abatement and Clean Room monitoring.

Omniguard 4: Features The Omniguard 4 utilizes state of the art pressure measurement technology to accurately document vacuum and pressure inside a containment area. With features designed to display information clearly and quickly, you ll be confident that you have the best instrument for the job. I F C E D J A H A 95 decibel audible alarm and status LED notify workers and bystanders when containment is lost D E Thermal printer, no ink ribbons Paper stores easily in protected compartment I Large graphics display shows current pressure, monitoring status and alarm settings at a glance B C USB and Serial ports support PC communication for transferring job logs to a computer Rugged self-contained unit includes USB cable, owner s manual, 10' of hose and spare paper roll stored in the case F G H Menu driven interface for easy set up and use Dual inlet ports allow monitoring between two areas Instant on screen help J Multiple reports available a the touch of a button

OMNIGUARD 4 Easy To Read The Omniguard 4 comes equipped with a thermal printer that provides a detailed, easy-to-read log of the pressure in the containment area as well as recording any changes made to the setup. Retrieving the data log is quick and easy. The Print Job key can be configured to print the log for the last one, two or three days or the entire job. Each of these reports offers the user specific, pertinent information and a hard copy record of the data logged from the containment area. Each printout provides a summary of the current job status, including the amount of time in Normal Operation, the number of Alarms and the amount time in Alarm Conditions (if any) along with an area for sign-off. Selecting View/Print Job Logs from the Menu allows you to print logs from previous jobs. In addition, a Configuration Report can be viewed and printed from the Menu Screen. The Configuration Report provides a hard copy of all of operational settings, memory usage and log space available. Job Report Typical startup sequence Setting changes print for verification Containment pressure reached operating window... Normal OP Alarm Condition (Alarm 1 tripped) Back into Normal Operation New Date prints at midnight Signoff header Summary Report Report title Job start and end date/time Time spent in Normal Operation Summary of all Alarm Conditions POWER OFF 11-21-03 19:48:39 CURRENT JOB Johnson Bldg OMNIGUARD 4 11-26-03 08:02:20 ALARM 1 @ -0.025" WC ALARM 2 @ -0.100" WC NEW TIME 05:38:00 NEW ALARM 2-0.090" WC NORMAL OP 05:51:24 TIME HI "WC LO "WC 06:06-0.032-0.028 06:21-0.031-0.027 06:36-0.033-0.028 ALARM 1 @-0.025" WC 08:51:26-0.012" WC 08:51:41-0.002" WC NORMAL OP 08:51:55 TIME HI "WC LO "WC 09:06-0.032-0.028 11-27-03 TIME HI "WC LO "WC 00:06-0.032-0.028 JOB REPORT 11-27-03 08:33:24 JOB NAME: Johnson Bldg CONTRACTOR: Acme Abatement SUPERVISOR: JOB SUMMARY JOB NAME: Johnson Bldg JOB START: 11-26-03 05:38 JOB END: 12-01-03 17:09 TIME IN NORMAL OP: 5 days 10 hrs 23 mins NUMBER OF ALARMS: 2 TIME IN ALARM: 16 mins 28 secs The Job Report shows all activity for a 24/48/72 hour period or the entire job. The specific report printed is selected by the Print Job key. The key can be configured to print one of several job report periods. Reports include both the Job Name and Contractor Name, along with an area for sign-off. The Summary Report is also printed whenever the Print Job key is pressed. The Summary Report provides a summary of the job status, including the amount of time in Normal Operation, the number of Alarms and the amount of time spent in Alarm Conditions (if any). In addition, reports for earlier Jobs or a Configuration Report can be viewed and printed from the Menu Screen. The Configuration Report provides a hard copy of all operational settings, memory usage and log space available. Software Combine the Omniguard 4 with your PC to create a powerful tool for monitoring a containment area. Use the included USB cable and free software to upload logs from the Omniguard for analysis and permanent storage. You can also use your PC to monitor the status of the Omniguard in real time using the USB cable or an optional serial cable. For even more flexibility add an external modem to the Omniguard 4 for true remote monitoring. You ll be able to check the current status of a containment area and upload the log from anywhere using your computer and a phone line. The current pressure and alarm status are right there on the screen. Even the status LED is shown. Log updates appear just as they are being printed on the Omniguard.

Features List Real time differential monitoring of pressure and/or vacuum level Extremely simple to set up and use Programmable high and low alarm setpoints Pressure displayed in units of Inches WC, Millimeters WC or Pascals 30+ day internal memory stores pressure readings and alarm occurrences with a date/time stamp Large easy-to-read graphic LCD display with backlight shows current pressure reading, operation status and alarm setpoints Multiple display modes allow easy viewing of pressure reading from a distance G Adjustable Print/Log interval to conserve paper and memory Variable response rate to avoid nuisance alarms in windy environments Passcode protection prevents unauthorized tampering with job settings Stores Contractor name for use in Job Reports The Omniguard 4 s case was designed so it could operate with the lid closed. A window in the lid lets you see the screen and there s a slot in the side for hoses and cables. Keeping the lid closed means water and dirt stay out and that means a pressure recorder that keeps on working. Print Job key can be configured to print the log from today, the past one, two or three days or the entire job when pressed Automatic printout and logging of all changes to settings Configuration report with current settings and monitoring status can be printed for easy review View Job Logs on screen, scroll through entire memory contents Temperature compensated circuitry reduces the need for offsite calibration B Off-site remote monitoring capability using optional external modem Relay output can trigger remote alarm, telephone autodialer or external fan units Windowed case lid allows viewing pressure reading and status with the lid closed to prevent damage to unit from water and other construction debris Operating temperature range 30-130 F Hang it by the handle, the hanging clip or just lay flat. The rotating screen lets you view the information no matter which way you look at it. 1 Year Warranty

Easy To Use The Omniguard 4 is a differential pressure recorder in a completely self-contained package. It was designed from the beginning to be extremely flexible yet easy to use. That ease of use starts when you set up the Omniguard 4. It comes in a durable, impact resistant case. Everything you need, including hose, a spare roll of paper and the AC cord, stores easily inside. It s easy to find a convenient spot for the unit at the job site since the Omniguard 4 is not position sensitive. You can lay it flat, stand it up or even hang it from a nail. The display can be flipped with the press of a button so that it s always readable and there s a window in the lid so you can see it when the case is closed. Once the Omniguard 4 is in place, the backlit graphics display makes it easy to configure the unit and monitor Multiple screens formats let you choose between the standard monitoring screen or an enlarged pressure reading that makes it easier to see from across the room. the status. Pressure is indicated with large easy-to-read characters and alarm setpoints are always displayed. 1 2 Screen icons show the monitoring, printer and audible alarm status with a glance. You also have the option of displaying only the pressure in even larger digits that can be read from across the room. Detailed information for job setup, feature settings, 3 4 operating instructions and troubleshooting are available on-screen at any time by pressing the Help key. The Omniguard 4 ensures the site inspector that proper containment was maintained. Pressure readings are time stamped and logged into memory once containment has been established. Audible and visual alarms activate whenever the pressure reaches the alarm setpoints. Logs and summary reports can be printed at any time for easy review. Durable and reliable, the Omniguard 4 is clearly the contractor s choice for containment monitoring. 1 Monitor Screen View current pressure reading and alarm settings. Monitoring status is shown at the screen bottom. Printer and Alarm status areindicated by on-screen icons. 2 Edit Screen (Alarm Setpoints shown) Make changes to configurable settings. Saved settings are logged into memory and printed to the report. 3 Main Menu 4 Help Info Screen Scroll through a menu of all functions, alter settings or get more info for the highlighted function with the Select or Help keys. Detailed information and operating instructions are available at any time by pressing the Help key. Troubleshooting topics are also covered.

Specifications Differential Pressure Range: +/-0.250 WC (+/- 6.35mmWC, +/-62.5 Pascals) Accuracy: +/-.003 WC or +/-1% of reading whichever is greater Resolution: 0.001 WC, (+/-0.05mm WC, +/-0.5 Pascals) Burst Pressure: 3 psi (20 kpa) on either inlet port Pressure Units Displayed: WC (Inches Water Column), mmwc (millimeters Water Column), or Pa (Pascals) Data Storage: 128,000 characters, 30+ days of readings (over 4,000 logged events) in non-volatile memory (no battery req d) Display: Graphic Liquid Crystal Display (LCD) with adjustable backlight and over 3.5 sq. inch viewing area Internal Clock: the internal clock is powered by a self-charging lithium-ion battery that provides 30+ days of clock operation when AC or DC power is not present Printer: 20 character wide thermal printer (uses 2.25 wide thermal printer paper) Printing/Logging Rates: Normal Operation highest and lowest pressure readings printed/logged at intervals of 5, 15, 30 minutes or OFF Alarm Condition current pressure reading printed/logged at intervals of 15, 30, 60 or 120 seconds for first 10 minutes of alarm condition, slowing to 15 minute intervals thereafter Alarms: Two programmable alarm setpoints, 95db audible alarm with flashing LED and on-screen warning indicate alarm condition Pressure Inlets: Two 3/16 OD barbed hose connectors, 10 ft of hose provided Serial Port: DB-9 Male, RS232 USB Port: USB V1.0 Type-B Aux Alarm Port: 1/8 stereo phono jack, relay contact outputs: NC, NO and Common rated 1A @ 30Vdc or 0.5A @ 115VAC Power: 115 VAC 60Hz with 6 ft power cord (220 VAC 50Hz optional,6vdc battery pack optional) Case: Dimensions 9.25 x 7.5 x 4.5, Shipping Weight 6 lbs., Material is copolymer polypropylene with polycarbonate window in the lid, handle and stainless steel hanging hook Warranty: One Year Limited Warranty Distributed By Accessories & Supplies Remote Auxiliary Alarm Battery operated high intensity strobe alarm with 95 db audible OG Comm Software CD (free download) Windows software retrieves recorded job logs from an Omniguard and saves them to a PC, also allows offsite remote monitoring of Omniguard 4 when used with the OG4 External Modem #OG-CSW Autodialer w/cable Calls a preprogrammed telephone number & plays prerecorded message to alert personnel in the event of an alarm condition at the work site #OG-Dial OG4 External Modem w/cable Allows remote offsite monitoring of Omniguard 4, also allows remote retrieval of job logs, requires access to standard telephone line/jack #OG-Modem External Battery Pack w/cable Powers Omniguard 4 for up to 48 hours when the printer is turned off, 12-24 hours with the printer on #OG-BatPk 220/240VAC Power Converts unit to operate using 220/240VAC 50Hz, requires modifications to Omniguard #OG-VAC220 Certificate of Accuracy Recalibration and Verification of accuracy of Omniguard (annual renewal recommended) #OG-Cert OG Owner s Manuals (free pdf download) OG Thermal Paper - 85' roll, 2.25" wide Box (5 rolls) - #TP201.Box Case (20 boxes) - #TP201.Case OG External Hose (3/16" ID) #OG-Hose (10') #OG-Hose100 (100') NIST Traceable Certificate - Verification of accuracy traceable to NIST Standards #OG-Nist Optional Pressure Ranges - CALL OMNIGUARD 4 Cables OG4 USB Cable 6' Connects Omniguard to a USB equipped PC to transmit job logs to PC, #OG4-USB OG PC Serial Cable 6' Connects Omniguard to serial port equipped PC, OG4 cable has DB-9 on both ends, OG3 cable has mini-stereo plug on one end, #OG(3,4)-SC OG4 Modem Cable 6' Connects Omniguard to an external modem (DB-9M to DB-9F) #OG4-MC Contact Information 6000 Southcenter Blvd. Suite 70 Tukwila, WA 98188 Phone (206) 241.9395 Fax (206) 241.9411 www.engsolinc.com Autodialer w/cable External Battery Pack w/ Cable Remote Auxiliary Alarm OG Thermal Paper - 85' roll OG External Hose (3/16" ID) Copyright 2004 Engineering Solutions, Inc. Omniguard is a trademark of Engineering Solutions, Inc.Product specifications subject to change without notice. Printed 4/04. Printed in the USA. 10M