*Note: For operation at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each 1000 ft. above sea level.

Similar documents
English, French & Spanish No Color

30" GAS RANGE INSTALLATION INSTRUCTIONS (For Models with Sealed Top Burners)

GAS COOKTOP INSTALLATION INSTRUCTIONS

IMPORTANT SAFETY INSTRUCTIONS

INSTALLATION INSTRUCTIONS FOR FREESTANDING DUAL FUEL

GAS COOKTOP INSTALLATION INSTRUCTIONS BEFORE YOU BEGIN. IMPORTANT Save these instructions for local electrical inspector s use.

INSTALLER: LEAVE THESE INSTRUCTIONS WITH THE APPLIANCE INSTALLATION MANUAL. 'Gas 30-inch Wide Free-standingRange

NATURAL GAS CONVERSION KIT

If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or death.

Installation Instructions Dual Fuel Ranges

gas Understanding Gas Appliance Conversions READ ALL INSTRUCTIONS

30" GAS FREESTANDING SELF CLEAN RANGE MODELS: WFG510S0HB0 (Black) 03/27/ Whirlpool Corporation Part No. W Rev. A

INSTALLATION INSTRUCTIONS

Installation Instructions. Parts Included. Materials Needed. Tools You Will Need. 30 Sealed Gas Cooktop

Installation Instructions

Installation Instructions Dual Fuel Ranges

COOKTOP, BURNER AND GRATE PARTS For Model: JGRP548WP00 (Stainless)

30" FREESTANDING GAS RANGE (AccuBake Temperature Management System) MODELS:

SERVICE UPDATE MANUAL FOR 30 GAS FREESTANDING RANGES

STOP! Read this notice. STOP! Read before proceeding. These instructions are for gas conversion of the Evergreen boiler only.

V SERIES HDR GAS RANGES

30" GAS FREESTANDING SELF CLEAN CONVECT RANGE (Fingerprint Resistant Stainless Steel) MODELS: MGR8800FZ0 (Stainless)

30 & 36 FLUSH-MOUNT GAS COOKTOPS

COOKTOP, BURNER AND GRATE PARTS For Model: JDRP430WP00 (Stainless)

Using it in an enclosed space can kill you.

COOKTOP, BURNER AND GRATE PARTS For Model: JGRP430WP01 (Stainless)

24 and 30 Gas Cooktops Tables de cuisson à gaz de 24 et 30 Superficies de cocción a gas de 24 y 30

Viking Installation Guide

Natural Gas Conversion Instruction for

30" SLIDE IN GAS CONVECTION RANGE MODELS: KSGB900ESS1 (Stainless Steel) 11/30/2016 Part No. W Rev. B

INSTALLATION INSTRUCTIONS

Multi-Function Cooktop

Conversion Instructions Logano G234X. Gas boiler. Please read carefully before installing and servicing. Gas boiler

COOKTOP PARTS. For Models: MGR8674AW0, MGR8674AB0, MGR8674AS0 (White) (Black) (Stainless) Illus. Part No. No. DESCRIPTION

INSTALLATION INSTRUCTIONS

ULTRA-MAX GAS RADIANT CHARBROILER. ULTRA-MAX GAS LAVA ROCK CHARBROILER MODELS 8024CBB, 8036CBB, 8048CBB, 8060CBB, and 8072CBB

GAS COOKTOP MODELS: CTG365D, CTG305D, CTG304D TO REDUCE THE RISK OF FIRE, ELECTRIC SHOCK, OR INJURY TO PERSONS, OBSERVE THE FOLLOWING

For use with models: PGM304-1, versions M-B PGM365-1, versions M-E, M-F & M-G

INSTALLATION INSTRUCTIONS 30" (76.2 CM) FREESTANDING GAS RANGES

INSTALLATION INSTRUCTIONS 30" (76.2 CM) FREESTANDING GAS RANGES

Viking Installation Guide

RESIDENTIAL GAS WATER HEATERS

21 20 LITER GAS FRYER FFA3200 INSTALLATION AND SERVICING.

IMPORTANT: SAVE THESE INSTRUCTIONS.

USER MANUAL Gas Countertop Charbroilers

HX Field Replacement Kit

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Cleaning Instructions for Burner, Pilot Assembly, and Emitter Screen. Series: LP Gas

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Stone Hearth Pizza Dome Oven

Gas Cooktop Installation, User and Service Instructions GMS 955.1

COOKTOP PARTS. For Models: KGRS308BSS0 (Stainless) Illus. Part No. No. DESCRIPTION

Applies to: Models F, B, FE, and BE FOR YOUR SAFETY

PROPANE CONVERSION INSTRUCTIONS. Applies to: Gas-Fired, Tubular Radiant, Low-Intensity Infrared Heater

CONVERSION TO PROPANE MANUAL M-Series Condensing Boiler. Wall-Mounted, Gas-Fired Boiler

Gas Conversion Kits and Instructions

Homestyle Stacked Washer/Dryer

Service Freestanding/Slide-In Gas Ranges

COOKTOP USER MANUAL & INSTALLATION INSTRUCTIONS

Viking Installation Guide

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

Hanover Outdoor Furniture IMPORTANT. If you have any problems with this product (missing or damaged parts, assembly issues, etc.),

USE AND CARE MANUAL AND INSTALLATION INSTRUCTIONS GAS SEALED BURNER

GAS COOKTOP INSTALLATION INSTRUCTIONS

OVATION SERIES FIRE TABLES ASSEMBLY INSTRUCTIONS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-400T DUAL FUEL CONSTRUCTION HEATER

Please read this manual completely before attempting to install, operate or service this equipment.

Installation Instructions Distinctive. Series Cooktop. Models DCT305, DCT365. Part No Rev. L

GE Monogram. Installation. Instructions. Professional Gas Cooktops 48" Natural Gas Models ZGU48N4GWSS ZGU48N6RWSS ZGU48N6DWSS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1000T DUAL FUEL CONSTRUCTION HEATER

D1/D2 Direct Vent Pilot Replacement Model #: D INSTALLER: Leave these instructions with consumer. CONSUMER: Retain for future reference.

Service Manual Model 3163

GAS WALL OVEN. Model: SGWO30SS OWNER S MANUAL. with INSTALLATION and MAINTENANCE INSTRUCTIONS

INSTALLATION INSTRUCTIONS

SIDEBURNER WARRANTY REPAIR KIT FOR OUTDOOR USE ONLY Repair kit For use with Char-Broil RED Series Grills Only.

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) F-1500T DUAL FUEL CONSTRUCTION HEATER

INSTALLATION INSTRUCTIONS

WHIRLPOOL CORPORATION assumes no responsibility for any repair made on our products by anyone other than qualified TECH-CARE Service Technicians.

Gourmet Freestanding Range Gas Cooktop Electric Oven

INSTALLATION INSTRUCTIONS

Service Manual For model N260 - a 2.4 cu. ft., 2-way refrigerator. For model N a 2.4 cu. ft., 3-way refrigerator.

GE Monogram. Installation. Instructions. Professional Ranges. 48" Natural Gas Models ZDP48N4GWSS ZDP48N6RWSS ZDP48N6DWSS

LGB Gas fired boiler

INSTALLATION INSTRUCTIONS

INSTALLATION INSTRUCTIONS

INSTALLATION GUIDE Dual Fuel Ranges

Viking Installation Guide

CATALINA FIRE TABLE ASSEMBLY INSTRUCTIONS

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

Homestyle Stack Washer/Dryers

HEARTH PRODUCTS KITS AND ACCESSORIES. KIT CONTENTS (See Figure 1) TOOLS NEEDED

OPERATING INSTRUCTIONS MANUAL (Please retain for future reference) FVN/P-400 INDIRECT FIRED SPACE HEATERS

USER MANUAL Gas Step Up Hot Plate

WARNING WARNING FOR YOUR SAFETY. Gas Conversion Kit Instructions. Applies to: Model UDAP, UDAS, UDBP, and UDBS Unit Heaters. General and Warnings

USER'S INFORMATION MANUAL

Installation & Troubleshooting Requirements

Installation Instructions Epicure. Cooktop. Models: ESG366, ESG486. Part No Rev. K

PROPANE CONSTRUCTION CONVECTION HEATER OWNER S MANUAL VARIABLE 30-80,000 BTU/HR ,000 BTU/HR

Installation Instructions Preference. Cooktop. Models: SGM304, SGM365, SGM466. Part No Rev. K

Transcription:

INSTALLATIONANDSERVICE MUST BE PERFORMED BY A QUALIFIED INSTALLER. IMPORTANT: SAVE FOR LOCAL ELECTRICAL INSPECTOR'S USE. READ AND SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE. This conversion kit must be installed by a qualified service technician in accordance with the manufacturer's instructions and all applicable codes and requirements of the authority having jurisdiction. Failure to follow instructions may result in fire, explosion or production of carbon monoxide causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation ofthis kit. The installation is not proper and complete until the operation ofthe converted appliance is checked as specified in the manufacturer's instructions supplied with this kit. Before proceeding with the conversion, shut offthe gas supply before disconnecting electrical power to the range. Be sure both power supplies are off before installing the conversion kit. Failure to do so could cause serious bodily injury. Determine the combination of top burners that are featured on your range. Then identify the parts you need from this kit to complete the LP. conversion. When burners are converted from Natural to LP the BTU rating is as follows: 5,000 BTU* Natural gas to 4,500 BTU* LP Gas 9,500 BTU* Natural Gas to 8,000 BTU* LP Gas 2,000 BTU* Natural Gas to 0,000 BTU* LP Gas 4,000 BTU* Natural Gas to,000 BTU* LP Gas Quantity 4 Part Number 36037526 3624805 3600525 3600526 3600527 3600528 3600529 36005220 3600522 36005222 3624200 36237904 36237905 36237906 36237907 Part Description L.P. Conversion Kit Label Instructions for converting range to LP Gas L.P. Conversion Label -,000 BTU* - 0,000 BTU* - 8,000 BTU* - 4,500 BTU* Notes English and French English, French and Spanish 4-8K 3+ 2++ +++ 4-8K 3+ 2++ +++ English, French and Spanish RED GREEN NO COLOR BLUE *Note: For operation at elevations above 2000 ft., appliance rating shall be reduced at the rate of 4 percent for each 000 ft. above sea level. IM PORTANT: After replacing the natural gas to LP orifices; be sure to keep the original factory installed natural gas orifices for future range conversion back to natura! gas. The factory orifices are marked with 0 for 5,000 BTU; 54 for 9,500 BTU; 75 for 2,000 BTU and 93 for 4,000 BTU. Tools Required for L.P. Conversion: 3/8", /2" and 5/8" Open End Wrench /8" Wide Flat Blade Screwdriver 7mm Nutdriver PIN 3624805 (004) Frangais - Pages 6-0 Espa5ol - Paginas -5

How to Convert the Range for use with LP/ Propane Gas. Convert the Pressure Regulator To access the gas regulator, remove the storage drawer or warmer drawer. If equipped with a storage drawer, open and remove the drawer completely. For models equipped with a storage drawer or front panel, remove the storage or front panel and skip steps a & b below. For models equipped with warmer drawer, follow all the instructions below to remove the warmer drawer. a. _!_ Electrical Shock Hazard can occur and result in serious injury or death. Disconnect electrical power to the range before removing the warmer drawer for servicing. b. Locate glide lever on each side of drawer, pull up on the left glide lever and push down on the right glide lever (See Figure ). c. Pull the drawer away from the range (See Figure 2). d. Remove the regulator access cover if equipped. Do not remove the Pressure Regulator or allow it to turn. e. Remove the dust protector from the cap. Using a 5/8" wrench, unscrew the cap from the pressure regulator. Do not remove the spring from the regulator. f. Turn the cap over so the hollow end faces outward. Place the solid end of the cap into the loop end of the dust protector (See Figure 3). g. Replace the cap on the regulator. The letters LP should be visible on the exposed end of the cap. Snap the dust protector over the regulator cap. Pull up with finger Pressure Front access to Regulator: Regulator Open storage or warmer drawer, located at or remove lower panel rear of (on some models) FIGURE 2 Spring Dust Protector Left Glide FIGURE 3 Hollow End Solid End Towards Towards Regulator Regulator for Natural Gas for LP/Propane Gas Natural Gas to LP Conversion for each type of burner 5,000 BTU Natural Gas converts to 4,500 BTU LP Gas Install(blue)orifice 68mm for LP 9,500 BTU NaturalGas converts to 8,000 BTULP Gas Install orifice (no coior),89mmfor LP Push down with finger FIGURE 4,000 BTU Natural Gas 2,000 BTU Natural Gas converts to,000 BTU LP Gas converts to 0,000 BTU LP Gas Install (red) orifice!.0mm for LP Install (green) orifice.95mm for LP FIGURE 4

Possible Surface configurations 4 NO COLOR ORIFICES O 5k Blue _O 9.5k No Color BLUE ORIFICE 2 NO COLOR ORIFICES GREEN ORIFICE FIGURE 5 9.5k-- O No Color 2k Green_l_Q A 3 NO COLOR ORIFICES GREEN ORIFICE _..2k Green 5k -----_O "_" Blue 9.5k No Color BLUE ORIFICE NO COLOR ORIFICE GREEN ORIFICE RED ORIFICE 2. Convert Surface s for use with LP/ Propane Gas [_[_J"_ Unlike the standard gas range, THIS COOKTOP IS NOT REMOVABLE. Do not attempt to remove this cooktop. Save the natural gas orifices removed from the appliance for possible future conversions to natural gas. For all burner locations: a. Remove the top grate and burner cap (See Figure 6). b. Use your hand to remove the burner head. c. Remove the four factory installed natural gas orifices from the center of the orifice holders using a 7 mm nutdriver (See Figure 7). Remember to keep the original Natural Gas s for later conversion to Natural Gas. Refer to page under "IMPORTANT" to identify their markings. d. Replace the orifice in each of the four orifice holders with the correct LP/Propane gas orifice (refer to the LP Kit chart listed on page ; also refer to Figures 4 and 5 for the correct LP orifice installation at each of the four surface burner locations). Tighten each orifice until snug. Use caution not to overtighten. e. Replace the four burner heads (be sure burner head mates correctly with each surface igniter) then replace the burner caps and grates. _ Use caution when replacing each burner cap so the electrode is not damaged. Cap_ _-_ Surface Inner Locatinc Ring Head 7mm Nut Driver Holder D('oNot _{ } Remove Electrode FIGURE 7 FIGURE 6 Surface Head Removable Drip Pan (on some models) 3. Convert Oven for LP/Propane Gas (6,000 BTU*) a. Locate the oven burner spud (See Figure 8). b. Using a /2" wrench, turn down the adjustable spud, which injects gas into the oven burner, until snug against the LP/Propane metering pin (approximately 2-/2 turns). Do not over tighten. 4. Convert Waist-High Broiler Flame for LP/Propane Gas (3,500 BTU*) mself- Cleaning Models Only a. Open the oven door. b. Locate the broiler burner spud and turn down until snug against the LP/Propane metering pin (approximately 2-/2 turns). Do not over tighten (See Figure 8). 5. Reconnect Gas and Electrical Supply to Range. Leak testing of the appliance shall be conducted according to the Installation Instructions provided with the Range.

Waist-High Broil / Self-Clean Models Pin 7. Air Shutter-Oven The air shutter for the oven burner may need adjustment, especially if the unit has been converted for use with LP/Propane gas. The approximate flame length of the oven burner is inch (distinct inner, blue flame) (See Figure ). " Flame Baffle Oven FIGURE 8 Checking Manifold Gas Pressure If it should be necessary to check the manifold gas pressure, remove the burner cap and connect a manometer (water gauge) or other pressure device to the top right front burner orifice. Using a rubber hose with inside diameter of approximately /4," hold tubing down tight over orifice. Turn burner valve on. For an accurate pressure check, have at least two (2) other surface burners burning. Be sure the gas supply (inlet) pressure is at least one inch above specified range manifold pressure. The gas supply pressure should never be over 4" water column. When properly adjusted the manifold water column pressure is 0" for LP/Propane gas or 4" for Natural gas. _ Do not use a flame to check for gas leaks, a. Disconnect the range and its individual shut-off valve from the gas supply piping system during any pressure testing of that system at test pressures greater than 4" of water column pressure (approximately /2" psig). b. The appliance must be isolated from the gas supply piping system by closing its individual manual shut-off valve during any pressure testing of the gas supply piping system at test pressures equal to or less than 4" of water column pressure (approximately /2" psig). To Surface "k FIGURE 9 FIGURE To determine if the oven burner flame is proper: a. To access the air shutter you must remove the warmer drawer, see instructions on page 9. b. Remove the oven bottom by removing the screws at rear of oven bottom. Lift up the rear of oven bottom and slide toward back of range to disengage from front of oven front frame. c. Remove burner baffle by removing nut located on top of baffle and two screws from front edge of oven front frame. Lift baffle straight up and out of the oven. d. Set the oven to bake at 350 F and observe the flame. If the flame is yellow in color, increase air shutter opening size. If the flame is a distinct blue color, but lifting away from the burner; reduce the air shutter opening size. e. Turn off oven and allow to cool before adjusting air shutter. To adjust loosen lock-screw (See Figure 2), reposition air shutter, and tighten lock-screw. Locking Screw FIGURE 2 Air Shutter (Spud) Hood Flame Size _l 5/8" l Retest the burner by repeating step "d" above. When the burner flame is a distinct blue color burning steady, the air shutter is adjusted correctly. f. Replace burner baffle and oven bottom. FIGURE 0 Main Top Test to verify if "LOW" setting should be adjusted: a. Push in and turn control to LITE until burner ignites. b. Push in and quickly turn knob to LOWEST POSITION. c. If burner goes out, reset control to OFF. d. Remove the surface burner control knob. e. Insert a thin-bladed screwdriver into the hollow valve stem and engage the slotted screw inside. Flame size can be increased or decreased with the turn of the screw. Turn counterclockwise to increase flame size. Turn clockwise to decrease flame size. (See Figures 9 and 0). Adjust flame until you can quickly turn knob from LITE to LOWEST POSITION without extinguishing the flame. Flame should be as small as possible without going out. Waist-High (Self Clean Models) ilower Oven Baffle.,,- Air Shutter (R_movable)... _... -_Lower Oven Bottorr (Removable) Air Shutter FIGURE 3

8. Air Shutter-Broil a. Observe the flame to determine if the broiler burner flame is properly adjusted. It should be steady with approximately " blue cones and no yellow or orange flame tips (See Figure 3). b. If adjustment to the air shutter is necessary, locate the broiler burner air shutter (See figure 4), loosen shutter lock screw, and adjust to obtain optimum flame. This will normally be completely open for LP/ Propane gas. If the flame is yellow in color, increase the air shutter opening size. If the flame is a distinct blue, but lifting away from the burner, reduce the air shutter opening size. Tighten the shutter set screw. Glide CONVERSION TO NATURAL GAS If it becomes necessary to convert the range back to natural gas: a. Disconnect gas and electrical supply from range. b. Convert pressure regulator (See step ), turn cap over so the solid end of cap faces outward. Place the hollow end of the cap into the loop end of the dust protector. c. Remove the four LP orifices using 7mm nutdriver and replace with the four original factory installed natural gas orifices at their original locations (See figure 4 for locations). d. Convert Oven for Natural Gas by loosening spud counter-clockwise (approximately 2-/2 turns; See step 3). e. Convert Waist-High Broiler (Self-Cleaning Models Only) for Natural Gas by loosening spud counter-clockwise (approximately 2-/2 turns). (See step 4.) f. Readjust "LOW" Setting for Surface Valves following instructions. (See step 6.) g. Readjust Oven & Broil Air Shutters. (See steps 7 & 8.) FIGURE 5 Oven Tube Lock Screw Air Shutter =_ Hood FIGURE 4 9. Replace Storage Drawer or Warmer Drawer (instructions for warmer drawer if equipped): a. Pull the bearing glides to the front of the chassis glide (See Figure 5). b. Align the glide on each side of the drawer with the glide slots on the range. c. Push the drawer into the range until levers "click" (approximately 2"). Pull the drawer open again to seat bearing glides into position. If you do not hear the levers "click" or the bearing glides do not feel seated remove the drawer and repeat steps "a" through "c". This will minimize possible damage to the bearing glides. 0. Installation of New LP/Propane Rating/Serial Plate Record the model and serial number on the LP/Propane Rating/Serial plate provided in this kit. The information can be obtained from the existing Rating/Serial plate. Place new plate as close as possible to the existing Rating/Serial plate on range (See the recommended locations shown in Figure 5). Remove Storage Drawer (some models), L.P. Rating/Serial Plate FIGURE 5 Pressure Regulator location at rear of range