LOCAL INVENTORY FOR QUICK SHIPMENT

Similar documents
Commercial, Residential & Institutional Pumps, Tanks, & Accessories

SmartDrive. SmartDrive. SmartDrive. SmartDrive

HYDRONIC SPECIALTIES TACO AC(F)-PAX 05/15/2008

HYDRONIC SPECIALTIES TACO MPT Tank(s) 05/30/2012. A. Multi-Purpose Tank buffer tank, air separator, and hydraulic decoupler

HYDRONIC SPECIALTIES TACO AC(F)-CA 05/08/2008

TECHNICAL. Series 18. Pump Packages

D. NEMA Compliance: Provide electric motors and components which comply with NEMA standards.

In-Line Air Separators

Hydronic Mechanical Panels

B. HI Compliance: Design, manufacture, and install pumps in accordance with HI "Hydraulic Institute Standards."

PhiloWilke Partnership Addendum No. 2 A/E Project No April 2016

C. ASSE 1013: Performance Requirements for Reduced Pressure Principle Backflow Preventers.

MECHANICAL. Product Index Mechanical Product Index

DENVER PUBLIC SCHOOLS DESIGN AND CONSTRUCTION STANDARDS This Standard is for guidance only. SECTION PUMPS

Taco 00 Series Cartridge Circulators

A. ASME Compliance: Fabricate and install hydronic piping in accordance with ASME B31.9 "Building Services Piping.

End-Suction Centrifugal Pump

End-Suction Centrifugal Pump

5. CONDENSATE PUMPS/UNITS

GH Series End Suction Centrifugal Pumps For Flows to 2,500 GPM

SECTION STEAM CONDENSATE PUMPS

B. Unit construction shall comply with ASHRAE 15 Safety Code, NEC, and ASME applicable codes (U.S.A. codes).

Update In Progress. Division 23 Heating, Ventilation, and Air Conditioning Page Section FLUID SYSTEMS EQUIPMENT PART 1 GENERAL

SECTION PLUMBING EQUIPMENT Piping (Plumbing). 2. Division 16 - Electrical Wiring and Connections.

Hard-hitting Contenders In HVAC Fluid Handling Solutions

Water Piping and Pumps

High Capacity Instantaneous Steam Fired Water Heater

Wilo IL Vertical Split-Coupled Inline Pumps

3020/3120 Series DEMING PUMPS. Frame-mounted and close-coupled Enclosded and semi-enclosed impeller Capacities to 4,000 GPM Heads to 780 feet

1900 Series In-Line Pump

LABORATORY AIR COMPRESSORS AND VACUUM PUMPING SYSTEMS

DS series STERLING PUMPS. Industrial End Suction Pumps ISO/DP

SECTION STEAM CONDENSATE PUMPS

University of Delaware

Silhouette. Feedwater Heater. Boiler Feedwater

Vent-Rite. Cast Iron And Steel Receivers. Simplex, Duplex, Triplex And Quadruplex Units. Pump Capacities To 150 GPM. Discharge Pressure To 75 PSI

MODEL P. 2 ft. NPSH Cast Iron Bronze Fitted Low NPSH Centrifugal Pumps. BULLETIN 112 Revised 7/09. PH (Horizontal Flange Mounted)

Experience In Motion. WXH and WXM Utility-Grade Multistage Ring Section Pumps

Essex County College - West Essex Campus Addition And Renovations dib # / SECTION HYDRONIC PIPING SPECIALTIES PART 1- GENERAL

Full-line Product Overview

SECTION PLUMBING EQUIPMENT

A. Operation and Maintenance Data: For pumps to include in emergency, operation, and maintenance manuals.

Series 4302 & FILE NO: 43d.12 DATE: June 1, 2004 SUPERSEDES: 43d.12 DATE: July 15, dualarm Vertical In-Line Pumps

SENTRA Series Water Unit

C. ASME Compliance: Fabricate and label water chiller heat exchangers to comply with ASME Boiler and Pressure Vessel Code: Section VIII, Division 1.

Hydronic Specialties and Circulator Pumps

30 F to 300 F Process Temperatures* 1/2 to 7.5 HP Centrifugal Pumps ( GPM) 3/8-1 Solenoid Cooling Valves (VE & 300 F models)

CONTENTS. B. System Design and Performance Requirements

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Design and Construction Standards SECTION PLUMBING EQUIPMENT

BuildingName The Description of the Project P DOCUMENTS

Domestic Pump Series VCMD TM Combination Vacuum & Boiler Feed Unit

FLANGE-MOUNT CENTRIFUGAL PUMPS

Goulds 3600 Between-Bearing, Axially-Split, Multi-Stage Pumps. Goulds Pumps

FI / SFI Frame-Mounted End Suction Pumps

Instant hot water Feed-Forward system unlimited supply accurate to +/- 4 F

TYPE LF/LC/LCV END SUCTION PUMPS

4VH and 4VHX. 4" Non-Clog Wastewater Pumps Standard (4VH) and Explosion-Proof (4VHX) Construction

SECTION HEATING BOILER FEEDWATER EQUIPMENT

dualarm Vertical In-Line Pumps

SECTION (15486) - FUEL-FIRED, DOMESTIC WATER HEATERS

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y

SECTION PLUMBING EQUIPMENT

Pumps SELECTION OF A PUMP

OKLAHOMA STATE UNIVERSITY - BUILDING DESIGN STANDARDS

TYPE VSM/VSMS VERTICAL SPACE MISER PUMPS

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Title: YALE OFFICE OF FACILITIES PROCEDURE MANUAL Chapter: 01 - Yale Design Standard Division: HVAC Standards

GT Series Single-Stage, Double Suction Horizontal Split Case Pumps

Brown University Revised August 3, 2012 Facilities Design & Construction Standards SECTION AIR HANDLING UNITS

PUMPS & PUMPING SYSTEMS FOR THE CHEMICAL PROCESSING & HEATING & AIR CONDITIONING INDUSTRY

380 Series Multi-Stage Centrifugal Pumps

Domestic Pump Condensate Transfer Equipment

Plate Water Heaters Brazed Plate Water Heaters-BPH Series Plate and Frame Water Heaters-PFH Series

Armstrong Flo-H2O Water to Water Instantaneous Heater Installation and Maintenance & Operation

Industrial. Solutions brands you trust. Product Overview

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y INDUSTRIAL PUMPS. Catalog

Peerless Pump Company

International Reactor Bulletin 1100 Corporation. Standard and Custom Reactors for the Chemical Process Industries

MASTERSPEC TECHNICAL SPECIFICATIONS DIVISION 22 PLUMBING

LN series STERLING PUMPS. Horizontal Split Case Pumps. Double Volute. Single Stage.

Allcan TM Installation Manual

Intelligent Variable Speed Pump

Goulds 3600 Between-Bearing, Axially-Split, Multistage Pumps

FM 517 San Leon, TX Toll Free: Office: (281) Fax: (281)

N N O V A T I O N E F F I C I E N C Y Q U A L I T Y CPO. Open Impeller ASME (ANSI) B73.1 Pump for continuous use in Chemical Process Services

PUMPS FOR INDUSTRY. The Vertical Pump Specialists CONTENTS: Introduction & User List. Product Overview. Vertical Process Pumps...

Grundfos is pleased to announce the sales release of many exciting new products.

FAIRBANKS NIJHUIS SOLIDS HANDLING PUMPS.

SERIES 24. Series 24 Features. Commercial, Forced Draft, Hot Water or Steam Boiler. The right fit for any commercial job

380 Series Multi-Stage Centrifugal Pumps

Hydronic Product & Application Catalog

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

PACKAGED AIR COOLED Product Data Catalog

FFH Series. Steam Fired Instantaneous Feed Forward Water Heaters

ecocirc XL HIGH EFFICIENCY LARGE WET ROTOR PUMP FOR HEATING, COOLING AND POTABLE WATER SYSTEMS A-162C

SERIES: WT SELF-PRIMING CENTRIFUGAL PUMPS

union swing check valve spring loaded check valve purging valve pressure relief valve relief valve metered balancing valve

470 Series Stamped Stainless Steel Pumps

Transcription:

LOCAL INVENTORY FOR QUICK SHIPMENT Territory Representation for Taco products since 1957: ALASKA 6657 Greenwood St. Anchorage, AK 99518 (907) 562 2608 (907) 562 0503 fax OREGON 27180 SW 95th Avenue Suite 3370 Wilsonville, OR 97070 (509) 534 8101 (509) 536 6034 fax COMMERCIAL PRODUCTS W. WASHINGTON 20715 50 th Avenue W. P.O. Box 5887 Lynnwood, WA 98046 (425) 774 1441 (425) 771 2590 fax In Stock & Ready to Ship! For other products offered by Proctor Sales visit us at our website: www.gopsi.com For Price & Availability Contact: pumps@gopsi.com

Commercial Pumps Applying or Replacement Whether designing a new hydronic application or simply replacing an existing pump or other hydronic equipment, Proctor Sales can help with design, application and selection. We have substantially increased our inventory levels of hydronic components to meet your demand. Most of the pumps we supply are custom assembled. The impeller is trimmed on our lathe to your specific application and a motor is mounted to match the electrical requirements of the job. In order to supply a quotation we need to following minimum information: 1. Flow requirements (GPM) 2. Head pressure required (Feet of Head) 3. Electrical motor requirements (Voltage and Phase) We can also provide a full size impeller with an integral variable frequency drive. Pump flow and head can then easily be adjusted to meet your particular application. These pumps are right off the shelf and available for quick replacement with a more efficient ECM motor. Our field technicians are also available to help set up. Motors and pump designs have improved dramatically in recent years. We can help you consider how to apply more efficient pump technology to your hydronic application. Please inquire with your application engineer about the following features: Do you need a starter or variable frequency drive? Taco can match the perfect drive or starter to your application. Electrically commutated motors (ECM) are available in a variety of sizes and are up to 85% more efficient. Would you like to consider ECM as an option? Sensorless pumps are available for variable speed pumping without external sensors. Are start up and flow measurement services required? Proctor Sales has trained field technicians who can help. Would you prefer a packaged pump station with control panel and electrical pre wired? Expansion Tank Replacement Proctor Sales has a wide selection of expansion tanks in stock. Chances are if you are replacing an expansion tank you need it in a hurry. It s also likely that a system issue has contributed to the bladder failure. We can help with solutions to both problems. See a list of our expansion tanks in this catalog and ask your application engineer for help with root cause analysis. You might also consider installing a new expansion tank with a removable bladder so complete replacement isn t required the next time.

Series Commercial Pump Type Materials GPM Range Stock VR3452 In Line, Wet Rotor, ECM Motor, Variable Speed Cast Iron 10 50 Complete Series VR15 30 In Line, Wet Rotor, ECM Motor, Variable Speed Cast Iron 25 375 Complete Series 100 In Line, Split Coupled Cast Iron 5 150 Complete Series 2400 In Line, Close Coupled Cast Iron 10 140 Complete Series 1600 In Line, Split Coupled Cast Iron or SST 20 200 Complete Series 1900 In Line, Close Coupled Cast Iron or SST 20 160 Complete Series KS Vertical In Line, Split Coupled Cast Iron 40 12,000 KV Vertical In Line, Close Coupled Cast Iron 40 2,400 Up to 4" thru 10 HP (500 GPM) FI CI Base Mounted, End Suction, Split Coupled Foot Mounted, End suction, Close Coupled Cast Iron 40 4,000 Cast Iron 20 2,200 Up to 4" inlet thru 30 HP (800 GPM) Series Pump Accessories Material Design Stock MPV Multi Purpose Valves Cast Iron 125 psig RSD PROCTOR SALES TACO COMMERCIAL INVENTORY Suction Diffusers (Rear Strainer Pullout) Cast Iron 125 psig 1 1/2" to 2 1/2" Threaded 3" to 6" Flanged 1 1/2" to 4" Flanged Pump Connection 2" to 5" Flanged System Connection ACUF Flow Balancing Valves, Circuit Setters Bronze 1/2 2" CI 2 1/2", 3", 4" 300 PSIG 125 psig 1/2" to 2" Threaded or Sweat 3" to 6" Flanged Series Expansion Tank Type Wetted Material Design Stock CA CX CBX PAX Full Acceptance, Field Replaceable Bladder Partial Acceptance, Non Replaceable Diaphragm Partial Acceptance, field replaceable membrane Partial Acceptance, potable water system design Butyl bladder 125 ASME 3 sizes up to 79 gallon volume Butyl diaphragm Molded rubber membrane FDA approved 125 ASME 125 ASME 125 ASME 6 sizes up to 41 gallon acceptance 7 sizes up to 43 gallon acceptance 6 sizes up to 43 gallon acceptance Series Air Separator Type Sizes in Stock Design Notes AD AC High Efficient Air and Dirt Separator In Line Air Separators 3, 4, & 6" Flanged 125 ASME 2", 2 1/2", 3", & 4" Flanged 125 ASME Removes Microbubbles down to 18 Microns Stocked with or without integral strainer Ships from Proctor Sales Warehouse: Wilsonville, Oregon 97070. Shipping lead times: In stock 1 2 days; Non stock 4 6 weeks Pumps: In stock motor 2 days; Non stock motor call for lead time Call for pricing and availability as quantities fluctuate due to demand.

- 5 - FI Series Pumps End Suction Split Coupled Base/Frame Mounted GPM: 40-4,000 Head (ft): 10-380 HP: 1/3-200 SIZES: 1-1/4 10 Cast iron casing with integrally cast feet enables pump to be bolted to base for sturdier installation. Allows for back pull without disturbing piping. Low-cost, replaceable wear rings protect casing during normal operation. Standard ceramic seals promote product flexibility, enabling basic product offering to meet a wide range of application requirements. Dry shaft design ensures shaft is never exposed to system fluid, eliminates need for expensive corrosion-resistant shaft, and simplifies sleeve and seal removal/reassembly. Rear pullout design allows pump to be serviced without disturbing system piping. 1/4 NPT pressure tapping on suction and discharge connections. Easy-to-replace slip-on shaft sleeve facilitates seal maintenance in the field and lowers long-term maintenance costs. Flush seal line tap allows installation of filter to protect seal from particles present in open systems. Top centerline discharge design simplifies piping layouts, reduces piping strain, and makes the pump self-venting. CI Series Pumps End Suction Close Coupled Foot Mounted GPM: 40-2,200 Head (ft): 10-380 HP: 1/3-50 SIZES: 1-1/4 8 Flush seal line taps allow for installation of filter to protect seal from particles present in open systems. 1/4 NPT pressure tapping on suction and discharge connections. Standard ceramic seals promote product flexibility, enabling basic product offering to meet a wide range of application requirements. Low-cost, replaceable wear rings protect casing during normal operation. Top centerline discharge design simplifies piping layouts, reduces piping strain, and makes pump self-venting. Cast iron casing with integrally cast feet enables pump to be bolted to a housekeeping pad for sturdier installation and still allow back pullout without disturbing the piping. Dry shaft design ensures shaft is never exposed to system fluid, eliminates need for expensive corrosion-resistant shaft, and simplifies sleeve and seal removal/ reassembly. Easy-to-replace slip-on shaft sleeve facilitates seal maintenance in the field and lowers long-term maintenance costs. Rear pullout design allows pump to be serviced without disturbing system piping.

- 6 KS Series Pumps Vertical In-Line Split Coupled GPM: 40-12,000 Head (ft): 10-380 HP: 3/4-600 SIZES: 1-1/2 14 Designed for optimum performance and ease of installation and maintenance. Ideal for HVAC and industrial applications. The split coupler design permits changing of the seal without disturbing the motor or the piping. The axial load is hydraulically balanced to increase bearing life, better pump efficiencies, and lower NPSH requirements. The recirculating line flushes seal faces and extends seal life. Optimum pump efficiency is achieved by close running impeller to casing clearances. KV Series Pumps Vertical In-Line Close Coupled GPM: 40-2,400 Head (ft): 10-380 HP: 3/4-100 SIZES: 1-1/2 8 Designed for optimum performance and ease of installation and maintenance. Ideal for HVAC and industrial applications. Space saving design that doesn t require isolation pads. Closed coupled design provides improved alignment and increased seal life. The axial load is hydraulically balanced to increase bearing life, better pump efficiencies, and lower NPSH requirements. The recirculating line flushes seal faces and extends seal life. Optimum pump efficiency is achieved by close running impeller to casing clearances. NOTE: All pumps are also available with 50Hz or 60Hz motors

- 9-2400 Series Circulators In-Line GPM: 4-90 Head (ft): 2-46 HP: 1/10 1/2 SIZES: 3/4 3 1900 Series Pumps Close Coupled In-Line GPM: 20-250 Head (ft): 10-160 HP: 1/4 7-1/2 SIZES: 1-1/2 2 Close coupled compact design is energy efficient and installs anywhere in the piping layout. Self-supporting design allows horizontal or vertical installation. Pump and sealed ball bearing motor are maintenance-free Rear pullout design and standard motor promote simple, easy service. One seal and shaft sleeve fits all models, assuring superior parts flexibility. SCX1700 Series Pumps Stainless Steel Close Coupled GPM: 10-100 Head (ft): 25-135 HP: 1/2 2-1/2 SIZES: 1 1-1/2 NOTE: All pumps are also available with 50Hz or 60Hz motors

- 10 1600 Series Pumps In-Line GPM: 20-200 Head (ft): 10-68 HP: 1/4 3 SIZES: 1-1/2 2 Rugged casing design has maximum operating pressure of 175 psi and a maximum operating temperature of 300 F. The 1600 Series is offered in cast iron stainless steel-fitted or all-stainless steel construction. Permanently lubricated long-life bearing cartridge replaces conventional wick type bearing/bracket assembly. Single bearing cartridge services the entire product line. One-piece enclosed impeller assures long life and higher pump efficiencies. Standard mechanical seal assures maximum flexibility. One seal fits all models; several materials available. Flexible coupler absorbs shock, vibration and misalignment that could be transmitted to the cartridge and motor bearings while also isolating and preventing any motor related noise or vibrations from being transmitted to the system. Resilient mounted motor ensures quiet, reliable pump operation. One bearing cartridge, one seal, and two motor frames fit all pump models, assuring superior parts flexibility. 121-138 Series Circulators In-Line GPM: 10-150 Head (ft): 5-38 HP: 1/4 1 SIZES: 2-1/2 3 110-120 Series Circulators In-Line GPM: 5-65 Head (ft): 2-22 HP: 1/12 1/3 SIZES: 3/4 2 NOTE: All pumps are also available with 50Hz or 60Hz motors

- 12 Viridian, Web-Enabled, High Efficiency Circulators Wet Rotor, Variable Speed GPM: 10-350 Head (ft): 5-46 HP:.027 2.175 SIZES: 1-1/2 to 3 A Viridian pump and iworx is a great combination. Viridian VR15 to VR30 Up to 85% energy savings Internally sensed variable speed operation ECM motor Heating or cooling applications Viridian web connections are a snap. Operating Modes: Constant Pressure Control (Δp-c) Variable Differential Pressure Control (Δp-v) - factory default Proportional Pressure Control Constant Curve Duty (uncontrolled pump) RPM Regulation Power Limitation NOTE: All pumps are also available with 50Hz or 60Hz motors

- 13 - Viridian VT2218 circulator is a temperature sensing, self-adjusting, variable speed wet rotor circulator with an ECM permanent magnet motor. Operating modes include Delta-T differential temperature, 4 fixed speeds, set point heat, set point cool and boiler protection. Δ-T operation can save hundreds in fuel costs The only temperature-sensing pump in its class High-effciency ECM motor uses up to 85% less electricity 5 operating modes for maximum application flexibility Big, bright LCD screen Innovative BIO Barrier protects the pump from system contaminants Viridian VR1816 circulator is an infinitely variable speed, high effciency wet rotor circulator with an ECM permanent magnet motor. Operating modes include infinitely variable fixed speed and self-adjusting constant pressure or proportional pressure variable speed. High-effciency ECM motor uses up to 85% less electricity Infinitely variable speed settings to fine tune flow for any system Six pressure presets to fit the job 5 color LED displays - operating mode - error code diagnostics Sure Start automatic unblocking and air purging mode Viridian VR3452 is a high effciency wet rotor circulator for chilled and hot water applications. Settings easily managed with a user-friendly interface. The permanent magnet ECM motor saves up to 85% of the electrical energy compared to conventional pumps. High-effciency ECM motor uses up to 85% less electricity Auto mode (default) Proportional pressure control Constant pressure control Constant speed Night setback turndown Communication module (optional) NOTE: All pumps are also available with 50Hz or 60Hz motors

Plus Two Multi-Purpose Valve Horizontal or Vertical installation GPM: 20-10,000 Five (5) Valves in one: SIZES: 1-1/2 14 - Shut-off valve - Flow Control Valve (Globe Style) - Non slam check valve - Flow Metering Valve - 14 - Straight Pattern Valve can be converted to a right angle pattern valve Low pressure drop (Equal to or better than any comparable valve on the market today) Suitable for 125 and 250 PSI W.P. Suction Diffuser Rear Strainer Pullout (RSP) Suitable for 125 & 250 PSI W.P. GPM: 20-10,000 SIZES: 1-1/2 16 Integral cast straightening vane design ensures uniform flow to the suction inlet of the pump Oversized Body Cylinder ensures minimal pressure drop Removable Cover Plate and reusable O ring allows for easy access and maintenance of Permanent Strainer Blow Down port allows for routine maintenance and removal of sediment and debris Optional Magnetic Insert to trap small metallic particles Specifically designed to serve the needs of commercial HVAC and industrial applications. Accu-Flo Balancing Valve Fixed Port Venturi Balancing Valve GPM: 1/2-1000 SIZES: 1/2 4 Flow measurement independent of stem and ball position. Modified venturi flow measurement section ensures precise and consistent differential pressure readings. Positive shut-off ball valve for service work. Can be installed in any position Tamper resistant memor y stop 1/2 2 available in sweat and NPT connections. 2-1/2, 3 and 4 available flanged connections.

- 15 - Plate & Frame Heat Exchangers ASME designed and constructed GPM: 50-7000 CONNECTION SIZES: 1 20 TFP & TMP Brazed Plate Heat Exchangers ASME designed and constructed GPM: 1-200 5 x 12 and 10 x 20 CONNECTION SIZES: 3/4 2 Rugged, reliable Taco Brazed Plate Heat Exchangers represent the latest technology in high-performance heat exchangers. These compact units feature copper brazed, stainless steel plates that offer a highlyefficient, low fouling transfer service. All units have male pipe thread fittings and mounting stud bolts are standard. Computerized product selection helps you choose the heat exchanger that s just right for your application. Their compact size and ease of servicing, coupled with Taco dependability, make the PF Series the perfect choice. Shell & Tube Heat Exchangers Leak Guard, Double Wall Steam to Liquid Liquid to Liquid CONNECTION SIZES: 1 14 4-30 diameter Up to 10 long Shell & Tube Heat Exchangers U and Straight Steam to Liquid Liquid to Liquid CONNECTION SIZES: 1 14 4-30 diameter Up to 10 long

EXPANSION TANK CA STYLE MODEL VOLUME (LITERS) VOLUME (GALLON) CA90 125 90 23 CA140 125 140 37 CA300 125 300 79 EXPANSION TANK PAX STYLE MODEL TANK VOLUME (GALLON) ACCEPTANCE VOLUME (GALLON) PAX30 150 8 5 PAX42 150 11 5 PAX84 150 22 12 PAX215 150 57 31 PAX254 150 67 31 PAX300 150 79 43 EXPANSION TANK CX STYLE MODEL TANK VOLUME (GALLON) ACCEPTANCE VOLUME (GALLON) CX30 125 8 5 CX42 125 11 5 CX84 125 22 10 CX215 125 57 27 CX254 125 67 27 CX300 125 79 41 EXPANSION TANK CBX STYLE MODEL TANK VOLUME (GALLON) ACCEPTANCE VOLUME (GALLON) CBX30 125 8 5 CBX42 125 11 5 CBX84 125 22 12 CBX130 125 34 19 CBX170 125 45 24 CBX254 125 67 34 CBX300 125 79 43

- 16 4900 Series Air & Air/Dirt Separators ASME designed and constructed GPM: 0-30,000 CONNECTION SIZES: 3/4 36 5900 FlexBalance and 5900 FlexBalance~Plus Hydraulic Balancer Designed, Manufactured and tested to ASME Section VIII, Div. 1 GPM: 0-1,500 CONNECTION SIZES: SIZES: 2 12 Optional removable Heads and Pall Ring baskets (recommended on open systems) Patent# 5, 123, 938 Micro Air bubble removal to 18 Microns Dirt particle removal below 30 Microns Size range from 2 to 36 / W.P. at 125, 150 or 250 PSI. ACT Tangential Air Separators ASME #125 construction GPM: 0-10,000 CONNECTION SIZES: 2 36 5900 FlexBalance~Plus 5900 FlexBalance Patented 5900 FlexBalance and FlexBalance~Plus Separators act as a hydraulic bridge between the primary and secondary circuits in hydronic heating and cooling applications. The FlexBalance~Plus product line incorporates patented Pall Ring technology for deep micro-bubble and dirt removal. Air Separators ASME #125 construction GPM: 0-10,000 CONNECTION SIZES: 2 36 Save money and extend the life of system pumps, piping and components with Taco ACT Series air removal units. The ACT air separator is designed and constructed to the ASME Boiler & Pressure Vessel Code, Section VIII, Division I for unfired vessels. Stainless steel removable strainer (optional) 375 F max. operating temperature Higher working pressures available.

4900 SERIES AIR & AIR/DIRT SEPARATORS MODEL SIZE 4903AD 125 3 4904AD 125 4 4906AD 125 6 AIR SEPARATORS IN LINE MODEL AC MODEL AC02F 125 PIPE SIZE 2 w/strainer AC025 125 2 1/2 AC03 125 3 AC03F 125 3 w/strainer AC04 125 4 AC04F 125 4 w/strainer Note: All models are 125 psi & flanged

Proctor Sales Inc. Manufacturers Representative BOILERS & WATER HEATERS Condensing boilers, semi-instantaneous gas/steam water heaters Instantaneous water heaters, recirculation system temperature controls Water tube and heat recovery boilers, steam generators Flexible water tube boilers, deaerators, and feed systems Eutectic cast iron boilers Fire tube, firebox, vertical tubeless, & hybrid boilers, and boiler accessories Condensing and non-condensing commercial boilers and water heaters Electric boilers, water heaters and tanks Electric boilers Cast iron sectional boilers, baseboard radiation BURNERS & COMBUSTI ON CONTROLS Oil and gas fired burners Linkageless burners and combustion controls Heating system controls (residential & commercial) Burners - industrial and commercial alternative fuels ultra low NOx High efficiency, low NOx burners - all fuels (Oregon) VENTING ACCESSORIES Boiler breaching & stack, grease & engine exhaust ducts, heavy wall free standing stack Commercial ventilation and draft systems PUMPS & HEAT TRANSFER Engineered Air Radiant ceiling panels (Alaska & Washington) Submersible pumps Domestic water booster systems Brazed plate heat exchangers Submersible pumps Solar hot water systems, valves and controls Architectural radiant panels (Alaska & Washington) Pumps, heat exchangers, and hydronic specialties (AK, OR, Western WA) Heat transfer equipment STEAM SPECIALTY & PIPING COMPONENTS Radiant floor heating & hot/cold water systems Steam traps, PRVs, condensate pumps Modular floor & wall seals, wall sleeves (Oregon) Flexible connectors, expansion joints, valves and strainers Control valves, automatic flow controls and valve piping packages Pre-insulated flexible and containment piping systems (Alaska & Washington) MISCELLANEOUS Control valves, temperature and pressure regulators Condensate return and boiler feed units Air & water cooled chillers and heat pumps; fan coils, VMF (Alaska & Washington) Glycol Feeders Condensate Neutralizers (Oregon & Washington) Water Source Heat Pumps, PTAC, Fan Coils Vertical unit ventilator, self-contained AC & heat pumps (Alaska & Washington) www.gopsi.com (see reverse for locations) Air Handling (Alaska, Washington & N. Idaho)