Crossrail Fire Safety Designs

Similar documents
Crossrail. Clare Hebden; September 2012

Underground fires in metro systems failures, accidents and terrorism

Fire Protection and Safety in Tunnels Conference Opening Remarks. Dr Fathi Tarada Secretary, PIARC Tunnel Operations Committee

Hot Issues in Fire Engineering July 2014

Case Study 1 Underground Car Park

CFD ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

Jonathan Redding Area Sales Manager FOGTEC Fire Protection Cologne, Germany

BUILDING INDUSTRY TUNNEL RAIL TUNNEL FIRE FIGHTING WITH HIGH PRESSURE WATER MIST

Recent European and national German regulations for. measures

CFD-AIDED TENABILITY ASSESSMENT OF RAILWAY TUNNEL TRAIN FIRE SCENARIOS

Ventilation for Smoke Control, Fire Control & Life Safety in Tunnels. Dr. Ricky Carvel BRE Centre for Fire Safety Engineering University of Edinburgh

New pockets of a city. Three Elizabeth line stations London

Third Runway Project APM Depot Fire Engineering Design. Presented by Ir Wilson Sau-kit TSANG

The Mont Blanc tunnel project. Eric CESMAT, Sylvain DESANGHERE

Impact of quick incident detection on safety in terms of ventilation response

Crossrail. Supplementary Environmental Statement 2. Utilities Assessment Additional Information

incorporating Contractors guide to car park ventilation A no-nonsense guide to the safe ventilation of underground and covered car parks

Emergency Ventilation System Design - Preliminary Report Shishir Gupta

NUMERICAL STUDIES ON BARE CABIN FIRES WITH OPERATION OF SMOKE EXTRACTION SYSTEM

Case Study 1 Underground car park

Innovative Solutions for Active Fire Protection in Road/Rail Tunnels and Underground Facilities

6B-2 6th Asia-Oceania Symposium on Fire Science and Technology 17-20, March, 2004, Daegu, Korea

Increasing Fire Safety of Cologne Main Station by High Pressure Water Mist

Adrian Milford Sereca - a Jensen Hughes Company, Project Engineer Vancouver, BC, Canada

Chapter 24 Route Window SE5 Arsenal Way shaft. Transport for London

Fire Detection and Fire Fighting Testing and Approval on Railway Vehicles

NUMERICAL SIMULATION OF FIRE SPREAD IN TERMINAL 2 OF BELGRADE AIRPORT. PO Box 522, Belgrade, Serbia and Montenegro

Operational Safety in the underground facilities of a deep geological disposal of nuclear waste


Appendix AUSTRIA Vienna Kaisermühlentunnel

21. GREENWICH ROUTE SECTION ENVIRONMENTAL BASELINE AND ASSESSMENT OF IMPACTS... 2

Tokyo-wan Aqualine - Experience of Traffic and Safety

Chapter 9 Route window W18 Slough station. Transport for London

CHOOSING A FIRE VENTILATION STRATEGY FOR AN UNDERGROUND METRO STATION

General Principles of Smoke Control

THE GOTTHARD BASE TUNNEL: FIRE / LIFE SAFETY SYSTEM

COMPENSATORY EFFECTY OF FIXED FIRE FIGHTING SYSTEMS IN TUNNELS

How to Use Fire Risk Assessment Tools to Evaluate Performance Based Designs

Crossrail Project. Infrastructure design and construction Volume 5. Edited by Professor Rhys Vaughan Williams and Mike Black

Mass Notification and Intelligent Response TM The European Way

Gerd Koffmane, Henrik Hoff, AP Sensing GmbH, Böblingen

REVIEW OF TECHNICAL STANDARDS AND CALCULATION METHODS FOR DIMENSIONING OF SMOKE AND HEAT CONTROL SYSTEMS IN CASE OF FIRE IN UNDERGROUND CAR PARKS

Mobile ventilation units in tunnels

Smoke Management in Subway Stations Due to Train Arson Fire Scenario

Provisions for the Means of Escape and Means of Access by Using Lifts and Escalators in the MTRC Main (U/G) Station

Fire protection of emergency electrical devices: effect on the level of risk a case study of a rail tunnel

DMRC at a Glance. Registered : May Construction Commenced : Oct Operation Commenced : Dec Operates 213 RKM in 7 lines, 158 Stations

Sprinklers Modeling for Tunnel Road Fire Fighting

Japanese Case Study: How to maintain the fire safety in subway station and tunnel

Fire and smoke management in a uni-directional road tunnel for a congested traffic condition

Case study of a Transport Centre

Appendix SPAIN Madrid M30-Río-TUNNEL

technical specification smoke venting systems

The role of smart infrastructure and construction for next generation cities

EUROPEAN BUREAU. EuroTAP European Tunnel Assessment Programme

A comparison between emergency ventilation systems semi-transvers ventilation and natural ventilation in Road Tunnel A

STUDY FOR SAFETY AT A RELATIVELY SHORT TUNNEL WHEN A TUNNEL FIRE OCCURRED

The possible use of evacuation modelling tools for the rolling stock

20. NEWHAM ROUTE SECTION - ENVIRONMENTAL BASELINE AND ASSESSMENT OF IMPACTS... 2

Fire Safety in the Channel Tunnel

Tunnel Fire Dynamics and Evacuation Simulations

VENTILATION & FIRE SAFETY

FIRE SAFETY POLICY LEEDS METHODIST MISSION. Oxford Place Centre

FROM THE CLASSICAL FIRE-FIGHTING WATER SUPPLY TO STRUCTURE AND SMOKE-GAS COOLING, TAKING THE GLEINALM TUNNEL AS AN EXAMPLE, PART I

FOGTEC Rail Systems. Rolling Stock Applications. Fire Protection Solutions from one source. Leading in Fire Protection

Exova Warringtonfire - Expert Witness Directory 2018

Practicalities and Limitations of Coupling FDS with Evacuation Software

A Brief on Performance- Based Design for Building Fire Safety

IFE Level 4 Certificate in Fire Science and Fire Safety

1. PIARC Update 2. Tunnel System

Health and Safety. MARIE COLEY ICAEW, Health & Safety Manager ICAEW 2017

TUNPROTEC. Active Tunnel Fire Protection

Computer Simulation Investigation on the Effect of Channelled and Unchannelled Screens on Smoke Contamination in Atriums Upper Balconies

Test One: The Uncontrolled Compartment Fire

FIRE DEPARTMENT - RULES FOR FIRE PROTECTION IN AUSTRIA

Fire Safety Concept Hotel Jumeirah

Regulatory Reform (Fire Safety) Order 2005 Category of Premises against the FSO 2005: Sleeping Accommodation

NEW PROJECTS DOCUMENTATION FOR OCCUPATION - REGULATION 38 FIRE STRATEGIES, DRAWINGS & INFORMATION EMPLOYER S REQUIREMENTS

Crossrail. Supplementary Environmental Statement 3. Mapping

Mechanical Smoke Extract Shaft Systems

Considerations in the Design of Smoke Management Systems for Atriums

FIRE RISK ASSESSMENT Retirement Housing (Independent Living) (v3.november 2016)

Welcome! Opening Remarks. FadyAbu Jamra, President of ASHRAE Qatar Oryx Chapter Mark Stevens, Executive Director, AMCA International

Building Consent Application Compliance Schedule Information

A Study into the Standardization of Using Fire Detectors in Rail Vehicles for China

30 top tips to tackle HVAC challenges No.21 - Fireman s override

Traffic & Transportation Jubilee Line Extension Tunnel

incorporating Guidance to Shafts for Smoke Control A useful guide to practical smoke shaft principals and specifications

12. Environmental baseline and assessment of impacts: Southeastern section

RISK-ORIENTED FIRE ENGINEERING APPROACH IN HONG KONG FOR THE NEXT GENERATION

Road tunnel safety rules in Italy: the tunnel country

Aspirating Gas Detection CFD Modelling Predicts Application Performance

FIRE SAFETY LOG BOOK. (Record of Fire Safety Equipment Testing)

Top tip No. 21 Fireman s override

2015 SFPE Europe Conference on Fire Safety Engineering

Ensuring safe passage HI-FOG for underground stations

Simulation of Full-scale Smoke Control in Atrium

FINDINGS FROM FIRE TESTS IN TUNNEL CONSTRUCTIONS WITH VENTILATION SYSTEMS AND FIXED FIRE SUPPRESSION SYSTEMS

THE TRUE FIRE SURVIVAL CABLE

ASSESSMENT OF TIMBER PARTITION MATERIALS WITH FIRE RETARDANTS WITH A ROOM CALORIMETER

Transcription:

6 th International Conference TUNNEL SAFETY AND VENTILATION Graz, Austria 23 rd 25 th April 2012 Crossrail Fire Safety Designs Author: Dr Yew Ting, PhD PGDip(BA) BEng(Hons) DipEng CEng MIMechE Co-authors: Mr David Eckford, Mr Oliver Dinsdale-Young Dr Hong Liang, Dr Iain Bowman

Contents Introduction to Crossrail Mott MacDonald recent involvement in fire safety designs Rolling Stock Reference design & compliance Smoke spread study Fire spread study Tunnel Fire Safety Systems Station Fire Safety Systems Future Crossrail Project Development

Crossrail Route Map 28 existing surface stations upgraded (11 major reconstructions) 90km of existing surface network Crossrail will connect 37 stations, including Heathrow airport and Maidenhead in the west with Canary Wharf, Abbey Wood and Shenfield in the east.

Central Area of Crossrail Route Map 22km of new sub-surface twin-bore railway through London CROSSRAIL STATION & ROUTE IN TUNNEL CROSSRAIL STATION & ROUTE ON SURFACE TUNNEL PORTAL BOX STATION BORE STATION 8 new sub-surface stations

Mott MacDonald s Recent Roles in the Crossrail Project Mott MacDonald s responsibilities in the key fire safety designs: fire safety aspects of the proposed open-wide gangway rolling stock; design fire size for the tunnel ventilation and platform smoke control systems; system-wide fire strategy for all of the tunnels; design of the smoke-control measures for the tunnels and all station platforms and of fire-fighting systems for the tunnels; fire strategies and fully-integrated detailed design for one of the major underground interchange stations at Liverpool Street.

Rolling Stock Reference design for Crossrail carriage: Two five-car sets per train, with Open-Wide Gangway runs the full length of the train. 20m long per car with three sets of double passenger doors, except the driving vehicles which have only two. Design must demonstrate adhere to the Code of Practice for Fire Precautions in the Design and Construction of Passenger Trains, BS 6853. All materials to be used in the rolling stock design must be suitable for use within a Category 1a environment (trains, which predominantly use tunnels).

Rolling Stock Geometry & Layout Plan view of end carriage layout Plan view of standard carriage layout The geometry and layout inside carriages influence the smoke spread characteristic and propagation of fire during a fire incident.

Rolling Stock Smoke Spread Study Open-wide gangway Passenger information display On-board fire in stand-back area Draught-screen Seating Luggage rack CFD techniques are used for the prediction of smoke propagation. Results are analysed by reference to suitable tenable conditions for passenger, prior to evacuation starting. Tenability conditions inside the carriage are assessed in terms of air temperatures, visibility levels, and carbon monoxide concentrations. Heat Release Rate (kw) 300 250 200 150 100 50 0 Simulation Period 0 1 2 3 4 5 6 7 Time (minute) 2 luggage cases, 16 kg Test case burned for 30 mins Calorimeter HHR = 284 kw peak @ 6 mins

Rolling Stock Smoke Spread Study (2) Car 4 Car 3 Car 2 Car 1 Fire Location

Rolling Stock Smoke Spread Study (3)

Rolling Stock Smoke Spread Study (4)

Rolling Stock Fire Spread Study Half carriage Open wide gangway Ignition source Platform-side doors

500kW baggage fire Rolling Stock Fire Spread Study (2)

Tunnels Fire Safety System / Strategy Platform & Ventilation Extraction Tunnel Extractions EXTRACT BY TUNNEL VENT SYSTEM Normal Conditions 1. Platform Fresh Air 2. Platform Cooling Fire Conditions 3. Platform 1.1 MW Fire Smoke Extract 4. Train 8.8 MW Fire Smoke Extract

Stations Fire Safety Systems Platform Ventilation Transformer Room Station Overview Plantroom Ventilation LV Switchroom Transformer Room Transformer Room Tunnel Vent Fans Sump Transformer Room Tunnel Vent Fans Sump LV Switchroom Plantroom Ventilation Accommodation Ventilation Platform Ventilation

Stations Fire Safety Systems Platform Ventilation Transformer Room Tunnel Ventilation Plantroom Ventilation LV Switchroom Transformer Room Transformer Room Tunnel Vent Fans Sump Transformer Room Tunnel Vent Fans Sump LV Switchroom Plantroom Ventilation Accommodation Ventilation Platform Ventilation

Stations Fire Safety Systems Platform Ventilation Tunnel Ventilation Blomfield Moorgate Tunnel Vent Fans Tunnel Vent Fans Platform Ventilation

Stations Fire Strategy Emergency evacuation routes for Crossrail s Liverpool Street station

Stations Fire Strategy (2) Escape routes Street level Fire Brigade Access Point Fire Brigade Access Point Blomfield Moorgate

Stations Fire Safety Design Escalator Open-space to ambient Columns Lift walls Handrails OPE Grilles Train Down-stands Running tunnel Open PSDs

Stations Fire Safety Design (2) Down-stand height from finished floor level = 4.75m 10m Visibility Envelope Incident side Non- incident side

Stations Fire Safety Design (3) Down-stand height from finished floor level = 3.65m (deeper down-stand) 10m Visibility Envelope Incident side Non- incident side

Stations Analysis Result Comparisons Down-stand height from FFL Visibility Contours 10m Visibility Envelope 4.75m Design Fail 4.25m Design Fail Bad 0 10 20 30 40 50 >60 Visibility contours at 2.5m height [m] Good

Stations Analysis Result Comparisons (2) Down-stand height from FFL Visibility Contours 10m Visibility Envelope 3.65m Good Design 2.80m Over Design Bad 0 10 20 30 40 50 >60 Visibility contours at 2.5m height [m] Good

CFD Modelling Tools & Techniques 3D CAD Geometry Mesh Generation CFD Processing CFD Post-Processing

Future Crossrail Project Development Enabling works Portal construction already started All tunnelling awards have been awarded and first tunnelling work commences in Q1 2012 Station construction is underway Plan opening date 2018.

Thank you for listening Dankeschön www.mottmac.com E: Yew.Ting@mottmac.com