XT-iP 210 Control Panel

Similar documents
XV 210 GPRS Control Panel

XL200L/600L/700L GPRS Control Panel

XTO-IP ALARM PANEL. Description. Supervised Wireless Technology. Features

Description Supervised Wireless Technology PRODUCT SPECIFICATION SHEET

Panel XTO210/610/710 GPRS

Panel XT210/610/ Description. Supervised Wireless Technology

Indoor MotionViewer IMV 200/601/701

ISMV STREAMING MOTIONVIEWER

OMV OUTDOOR MOTION VIEWER

1100D Wireless Receiver

Badge Reader BR Installation Guidelines. Product Summary

SZ-PIR04N ZigBee Motion Detector Installation Guide

QUICK START GUIDE. Lono, LLC 686 East 110 South, Suite 102 American Fork, UT 84003

1100X Wireless Receivers

2 x screws. 2 x wall plugs

Wireless External Alarm

Optima ZigBee Thermostat

Videofied Distributor Asfales - Oude Molenstraat Mol (b) (0)

XHS1-TY / MP-841 ZigBee Home Automation 1.2 Wireless Digital Pet Immune PIR Detector

Wireless Weather Station

Atomic Digital Office Clock

Intelligent Home Solutions Quick Start Guide. Monitor your home from anywhere with your smartphone

Wi-Fi DOOR/WINDOW SENSOR

NXSMP-LMI LOW MOUNT INDOOR SENSOR MODULE

ADT. Pulse 2017ADT LLC

Automatic Dimming Mirror with HomeLink

OPERATION MANUAL WARNING TO REDUCE THE RISK OF INJURY OR PRODUCT DAMAGE, READ OPERATION MANUAL PRIOR TO OPERATING PRODUCT.

Smart THERMOSTAT. Installation Manual

Model:T83646v2 Quick Setup Guide DC: WIRELESS WEATHER STATION

Rev D 3/20/17

TP WEM01 A Carrierr Côr Thermostat AC/HP Wi-Fir Thermostat Performance Series. Installation Guide

Impassa CDMA Module INSTALLATION GUIDE

Evolve 5.5 cu. ft. Medical-grade Undercounter Refrigerator

Smart Hub THERMOSTAT. Installation Manual

ShockLink. Important Product Information.

InTemp CX Temperature Logger (CX40x) Manual

Embedded Door Sensor. User's Manual. Model SS881ZB. For other language versions, please visit:

Wireless Outdoor Air Reset Adaptor PN:

Pet Immune SAW PIR Motion Sensor

Low Voltage Fan Coil Thermostat ST101ZB. Quick Start Guide. For other language versions, please visit

1 Copyright 2015 Alarm.com. All rights reserved. Rev 3.4

Draft - develop and review

1 Copyright 2014 Alarm.com. All rights reserved. Rev 3.3

1126 Series Ceiling Mount PIR Motion Detector

PET IMMUNE PIR MOTION DETECTOR

Touchscreen Comfort Control

SkyNEST WASP Portable Kit, Smart Receiver and SCADA Gateway with Solar Panel USER MANUAL

WIRELESS ALARM SYSTEMS CATALOGUE.

S541.RF 4G Product Guide

COMPLETE SETUP AND PROGRAMMING MANUAL FOR XT610/XTX610/XTO610 GPRS PANELS

1134 Wireless Wiegand Module INSTALLATION AND PROGRAMMING GUIDE

Xtender Panel Installation Guide Specification and Features

Tech Support Line: (715) Concord 4 RE927X

Water Sensor. Model CFWS10

EN1221S-60 Waterproof Pendant Installation and Operation Manual

HOBO MX Temp/RH Data Logger (MX1101) Manual

1125 PIR Motion Detector

Installation Guide. Model TBZ48A Battery Powered Z-Wave Thermostat. This thermostat is compatible with most HVAC systems, including the following:

Intelli-Time Alarm Clock model 13041RM

EL-TSTAT Owner s Manual

Features and content. This is where air comes into your detector.

SuperCELL Model SC500-H-SM User s Information

Nest x Yale Lock Programming/Troubleshooting Guide

Smart Radon Detector with Indoor Air Quality Sensors

ecobee 3 Quick Start Guide Installation Guide DRAFT

Smart Radon Detector with Indoor Air Quality Sensors Version 1, May 8, 2018

DT8050A DUAL TEC Motion Sensor with Anti-Mask - Installation Instructions

Projection Alarm Clock

Caught a critter in the act?

nextouch Touchscreen and Push Button Access Cylindrical Lock Installation and Programming Instructions

Contents. User Manual GA-U-1. VultureNet: Long Range System

Installation Guide

1164/1164NS Wireless Smoke Detector INSTALLATION AND PROGRAMMING GUIDE

Yale Real Living Key Free Push Button Deadbolt B1L Installation and Programming Instructions

RE6100 Series Helix Security and Automation Platform E I D

FTN-RRHW/FTN-RRIX FTN-RR2G/FTN-RRDS

Installer Guide smart connect

Yale Real Living Key Free Push Button Deadbolt B1 with Installation and Programming Instructions

Installer Guide smart connect

Monnit Wireless Local Alert. User s Guide

EN1221S-60 Waterproof Pendant Installation and Operation Manual

powered by Note: This manual applies to several packages. As such, some parts and some steps may not pertain to the package that you purchased.

Register the Gateway via PC. Package Content. Gateway Installation. 1 x Gateway 1 x Voice Siren 1 x IP Camera*

Yale Real Living Push Button Deadbolt Installation and Programming Instructions (YRD210)

BE1310 Visit Smart hub

Technical support is also available by or by phone: (North America) (International)

Yale Real Living Push Button Lever Installation and Programming Instructions (YRL210)

1164/1164NS WIRELESS SMOKE DETECTOR

Smoke Bridge Owner s Manual

CLIP PG2 PowerG Wireless, Curtain, PIR Motion Detector

Home Comfort Control with Wi-Fi Model 8910W READ AND SAVE THESE INSTRUCTIONS. Owner s Manual. Includes Operating Instructions and Warranty Information

Wireless Weather Station. Table of Contents

Regulatory Compliance and Safety Information for Contol4 Model C4-16AMP3-B.

Remote Notification System Instruction Manual

Ion Gateway Cellular Gateway and Wireless Sensors

Yale Real Living Key Free Touchscreen Deadbolt Installation and Programming Instructions (YRD240)

OPTIMA ZigBee Thermostat

WIRELESS TEMPERATURE & HUMIDITY STATION INSTRUCTION MANUAL

with motion sensor ITM. / ART Model: LM55811 CARE & USE INSTRUCTIONS IMPORTANT, RETAIN FOR FUTURE REFERENCE: READ CAREFULLY

TX3 Series. TX3 InSuite. User Guide

Transcription:

XT-iP 210 Control Panel Description The XT-IP210 Indoor Panel with GPRS & Ethernet alarm panel is a Videofied wireless, battery operated security system. The control panel is designed for residential and small commercial security applications where video verification is needed or desired. The control panel is powered by four 3.6V Lithium batteries that last up to four years, with normal system activity. It can also be powered by a mains power supply. A dual-tamper function is active 24 hours, whether or not the system is armed. An alarm occurs if the control panel cover is removed, or if the control panel is removed from the mounting surface. The user can arm and disarm the system by entering his code on the external keypad. The panel is embedded with three programmable inputs and two programmable outputs. You can enhance radio or GPRS communication on the panel by connecting external antennas. Features > S 2 View : Spread Spectrum, Videofied, Interactive AES Encrypted Wireless technology provides optimum signal integrity and security. > Compatibility : works with all Videofied wireless devices. > Supervision of all devices (except remote keyfob). > Tamper detection : 24-hour dual-tamper function provides detection for both cover and wall removal. Control panel also monitors all system device tamper switches. > Zones / Devices : 25 maximum. > Areas : 4 maximum. Area 1 predefined from factory for entry/exit delay. Areas 2, 3, and 4 can be configured as needed. Supervised Wireless Technology The XT panel series, along with all Videofied devices uses patented S2View - Spread Spectrum, Videofied, Interactive, AES Encrypted Wireless technology, providing optimum signal integrity and security. Bi-directional RF communication between all system devices and the system control panel assure high signal reliability. Integrated antennas eliminate protruding wires or rods cumbersome to install and unsightly to consumers, and if damaged could lead to potential system communication problems. The panel supervises every device (excluding the remote keyfob) to monitor current open/close state, tamper condition, serial number, date of manufacture, firmware revision, and battery status. > Access codes : 20 maximum, 4-6 digits; one installer access code for on-site programming only. > Configuration/Programming : on-site using alphanumeric keypads. > Communication : reports to central monitoring stations using Frontel. > Video verification : video resolution of 320 x 240 pixels, 0 lux sensitivity, 5-frames per second for approx. 10 seconds total recording time. 220K MPEG file. > History/Event Log : maximum 4,000 events stored in flash memory that cannot be cleared or erased.

Configuration/Programming Complete system configuration/programming can be done on-site using alphanumeric keypads. Easy to understand text on a two line, 16-characters liquid-crystal (LCD) display guides you through programming, prompting you for simple yes/no or data entry responses. Complete punctuation symbols allow for accurate website/ip address entries and device location naming. Communication The panel reports alarms and other system events by using the Frontel protocol. Frontel provides complete system reporting information and video verification to a central monitoring station set up with the Frontel alarm receiving software. Video Verification Incorporating MotionViewer into the security system allows for video verification of intrusion alarms. When the system is armed and an intruder trips MotionViewer, the integrated camera captures a 10-second digital video clip which is sent to the central monitoring station by the control panel, which can forward them to an alert list. History/Event Log The XT-IP210 Control Panel control panel records and stores all system activities and events (armings, disarmings, alarms, access codes entered, system programming changes, etc.) in flash memory, that cannot be cleared or erased. The log accumulates a maximum of 4,000 events. As additional events occur, the control panel automatically deletes the oldest event. This ensures the most recent events reside in the log. The history/event log can be viewed using an alphanumeric keypad or downloaded at the monitoring station. 2

Compatibility The XT-iP series panel is compatible with all the Videofied wireless devices described in this page: Outdoor MotionViewer : Integrated PIR motion detector, night vision digital camera, infrared illuminators. The Outdoor MotionViewer detect intruders and capture a video of the intrusion which is sent to the panel over RF. OSX Outdoor siren is a wireless and battery-powered siren designed for use with a Videofied security system. The siren is normally installed outside of the building to warn the surroundings that an intrusion is occuring. The XTO-IP210 Outdoor GPRS and Ethernet alarm panel is a Videofied weatherproof, wireless, battery operated security system. The control panel is designed for outdoor commercial applications (constructions sites, cellular towers, remote sites, substations...). The box is water-resistant and temperatureresistant. The XMA210 Keypad is a battery operated wireless alphanumeric device designed for programing and operating Videofied security systems Outdoor Badge Reader with Prox-Tag: Allowing Arming/disarming of the system from outside the premices. The Prox-Tags are standard Mifare badges. 3

Notes de sécurité / (EN) Security notes / (DE) Hinweise zur Sicherheit Français Retirez les piles avant toute opération de maintenance! Attention! Il y a un risque d'explosion si l'une des piles utilisées est remplacée par une pile de type incorrect! Respectez la polarité lors de la mise en place des piles! Ne jetez pas les piles usagées! Ramenez-les à votre installateur ou à un point de collecte spécialisé. English Remove battery before any maintenance! WARNING, there is a risk of explosion if a battery is replaced by an incorrect type! Observe polarity when setting up the batteries! Do not throw used batteries! Bring them to your installer or a collection point. FCC Regulatory Information for USA and CANADA Deutsch Batterien vor jeglichen Wartungsarbeiten entfernen! Vorsicht, es besteht Explosionsgefahr, wenn eine Batterie durch eine Batterie falschen Typs ersetzt wird! Achten Sie beim Einsetzen der Batterien auf die Polung! Entsorgen Sie Batterien nicht im normalen Haushaltsmüll! Bringen Sie Ihre verbrauchten Batterien zu den öffentlichen Sammelstellen. FCC Part 15.21 Changes or modifications made to this equipment not expressly approved by RSI Video Technologies may void the FCC authorization to operate this equipment. FCC Part 15.105 Class B This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation. This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occur in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures: > Reorient or relocate the receiving antenna. > Increase the separation between the equipment and receiver. > Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. > Consult the dealer or an experienced radio/tv technician for help. Radio frequency radiation exposure information according 2.1091 / 2.1093 / OET bulletin 65 This equipment complies with FCC radiation exposure limits set forth for an uncontrolled environment. This equipment should be installed and operated with minimum distance of 20 cm between the radiator and your body. This transmitter must not be co-located or operating in conjunction with any other antenna or transmitter. This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry Canada. Operation is subject to the following two conditions: 1 This device may not cause harmful interference, and 2 This device must accept any interference received, including interference that may cause undesired operation. Le présent appareil est conforme aux CNR d Industrie Canada applicables aux appareils radio exempts de licence. L exploitation est autorisée aux deux conditions suivantes: 1 L appareil ne doit pas produire de brouillage, et 2 L utilisateur de l appareil doit accepter tout brouillage radioélectrique subi, même si le brouillage est susceptible d en compromettre le fonctionnement. 4

Electrical data Power requirements (option 1) Power supply Type B 9-12VDC / 1,2A Low voltage limit 5,15V Backup 6V with 4 x 1,5 V D Alkaline batteries /LR20 Low battery limit 4,2V Battery life (average) 1 year Average current consumption (over 1h) 450µA Max current 1,2A RF S 2 View Technology Radio type Operating frequency Transmission security Radio jam detection Supervision Antenna External radio antenna Tamper detection Tamper Approvals Bidirectional RF 868/915/920 MHz AES algorithm encryption Integrated via MMCX connector Wall and cover tamper detection Programmable wired inputs Number 3 «Dry» contact Input voltage 12 VDC (15VDC max) Programmable wired outputs Number 2 Max switching voltage 24VDC /30VAC Max switching current 1A Max switching power 30 W EN50131-1: 2007 - Grade 2 Class II EN50131-3:2009 - Grade 2 & RTC 50131-3:2009 EN50131-4:2009 Grade 2 & RTC 50131-4:2009 EN50131-5-3:2005 - Grade 2 EN50131-6:2008 Grade 2 Type B & RTC 50131-6:2008 NF C 48-212:2004 NF EN50130-4:1995; A1:1998; A2:2003 NF EN50130-5: 1998 Class II GPRS Transmission Communicator Communicator type GPRS/Ethernet Security Protocol Frontel IP Stack TCP/IP Video transmission By Frontel protocol to central monitoring station GPRS antenna Integrated 2G frequencies 850 / 900 / 1800 / 1900 3G frequencies 800/850(B5), AWS1700(B4), 1900(B2) (XT-iP 630) 800/850(B5), 900(B8), 2100(B1) (XT-iP 730) External GPRS antenna via MMCX connector Video Video format Video size Video length MPEG Depending on camera type 10 seconds Miscellaneous Programming With remote Keypad Remote Devices per system 25 maximum Access Badges/codes 20 maximum Special arming mode 4 Number of Areas 4 History / Event log 4,000 events stored on flash memory Box Physical and Environmental Data Operating temperature -10 /+40 C Maximum relative humidity 75%, non-condensing Material ABS ULV0 Dimensions 225 mm x 180 mm x 55mm (LxWxD) Weight 520gr (without batteries) / 1600gr (with batteries) Installation/Mounting Control Panel/Base Two screws secures control panel cover to base; Three screws secure control panel base to the wall Honeywell Tel: +44 (0) 116 246 2000 Fax: +44 (0) 116 246 2300 Technical Support: +44 (0) 203 695 3191 Email: hlsuksalessupport@honeywell.com 140 Waterside Road Hamilton Industrial Park Leicester LE5 1TN 5