NIR O P E R A T I N G I N S T R U C T I O N S RETROREFLECTIVE PHOTOEYE U L M O N I T O R E D DEVICE

Operating Instructions

D-TEK O P E R A T I N G I N S T R U C T I O N S V E HI C L E L O O P DETECTOR Johnston Parkway, Cleveland, Ohio 44128

Operating Instructions

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

CarSense 303 O P E R A T I N G I N S T R U C T I O N S M A G N E T O R E S I T I V E V E H I C L E D E T E C T O R

Operating Instructions

SP-1000X. Panic Device Power Controller Installation Guide. Rev

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Public Safety DAS Annunciator Panel

DUAL OPTIC. Installation manual

Active Infrared Multi Beam Sensors

Installation Instructions

PT9420 (Extended Range)

English. Series. Installation and Use Manual

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

User's Manual: Series 260A Model 260A Process Current Loop-Powered Alarm

MVP-D-TEK Vehicle Loop Detector 9 Volts DC to 240 Volts AC. Operating Instructions

WM3000 WIRELESS MODULES

DISPOSER CONTROL CENTER

Installation Instructions Remote Blowers

Installation Instructions

Operating Instructions

SANDOR QUAD/ESA. Double beam. POLITEC s.r.l. Installation And commissioning manual

CONFIGURATION OF THE OPTICALS

PT101. General. Full Stroke Range Options. Potentiometer Cycle Life Maximum Retraction Acceleration. Electrical

Installation And commissioning manual. Series S Double Beam 1/16

136"ElectricCooktop. nstructlons _,00, JP961, JP968, JP969, ZEU769. I Iinstallation. -&WARNING - This appliance must be properly grounded.

Active Infrared Multi Beam Sensors. R Series

FUSION ALARMS TROUBLESHOOTING GUIDE CURRENT LIMIT VOLTAGE LIMIT

Rectifier RC-series. Manual RC-series English MA doc. Manual Wall and 19 English

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

Models NFPA 1221-A, NFPA 1221-B Public Safety DAS Annunciator Panel. Revision E 61117

OPERATING & SERVICE PARTS MANUAL 700ES ENERGY SMART WRAPPER SERIES C

130"ElectricCooktop. nstructlons _,0, JP355, JP910, JP930, JP940, JP950. I Iinstallation. -&WARNING - This appliance must be properly grounded.

Installation Instructions

Long-Range Barrier Sensors

DISPOSER CONTROL CENTER

DE5300 Delayed Egress System. General Information

D-TEK -MS Vehicle Loop Detector. Operating Instructions

136"ElectricCooktop. nstructlons. I Iinstallation. -&WARNING - This appliance must be properly grounded.

INDEX. Installation recommendation

ph COOLING TOWER CONTROLLER

Twin Photobeam Detectors Manual

ENERVEX ADC100 DRAFT CONTROL

MAINTENANCE & TROUBLESHOOTING GUIDE LEAK ALARM CHANNEL DRY OIL WATER AUX ALARM HIGH LOW CRITICAL WATER TANK LEVEL ALARM MODEL LDE-740 ADVANCE PAPER

Battery charger modules

CEILING FAN OWNER'S MANUAL

Model 3300 Technical Support and Installation Manual

FIRERAY 5000 range USER GUIDE

Remote Chexit Module (RCM) System. General Information

RK Combustible Gas Transmitter Operator s Manual

RK Carbon Monoxide Transmitter Operator s Manual

INDICE. Installation recommendation

INFRARED PERIMETRAL BARRIER DOUBLE BEAMS

D296/D297. Installation Instructions Long-Range Beam Smoke Detectors

ENGINEERED PARKING SYSTEMS MODEL 3416D

Model TL104 MANTL104. Test Lamp for Flame Detection

1. Quick start-up guide

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

AMERITROL, INC. INSTALLATION OPERATION MANUAL AND WIRING DIAGRAM LX SERIES LIQUID LEVEL SWITCH WITH ADDITIONAL TEMPERATURE TRANSMITTER

Viking Installation Guide

TABLE OF CONTENTS Flow Detect 1000 Specifications 3 Description 4 Principle of Operation 4 Detection Through Walls 4 Sensing Beam Shape 4 Installation

Greentrol Automation, Inc.

DIGITAL METERS Large Display Temperature Meters Instruction Manual

2 PREPARE THE OPENING

Ilnstallat!on. nstruct=ons. Before You Begin. Parts Included. Tools Needed. Built-In Wall Oven with Microwave ATTENTION INSTALLER

RK CO 2 Transmitter Operator s Manual

Centro-Matic Automated Lubrication Systems System Controls

Installation Instructions

Pioneer-R16 Gas Monitor Operator s Manual

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

PHOTOELECTRIC BEAM SENSOR PR-11BE : OUTDOOR 3.3 to 36ft. (1 to 11m) : INDOOR 3.3 to 49ft. (1 to 15m)

DISPOSER CONTROL CENTER

Installation Instructions 30 French Door Built-in Wall Ovens

Installation Guide. 15 W./24 W. Undercounter Refrigeration

TraceTek Sensing Module Installation, Operation and Maintenance Instructions DESCRIPTION SPECIFICATIONS APPROVALS TYPE NM

RELEASE DEVICES RELEASE DEVICE-WPS MODELS A/B INSTALLATION MANUAL U.L. LISTED CANADIAN LISTED CSFM: :100 GENERAL DESCRIPTION:

Installation Guide for AL300ULM. Multi-Output Access Control Power Supply Charger

Installation Instructions

Flame Simulator User Manual. Publication Rev. A

LC1350 Level Controller

INDEX. Installation recommendation

ELECTRIC COOKTOP INSTALLATION INSTRUCTIONS

EW 40 Wireless Fan Control

UV Scanner. Model Specification. Introduction. 854 Instruction Manual

LaserGuard2. Laser Collision Avoidance System. Part Number: R1 April 2015 Copyright 2015 Magnetek Material Handling

FIRE STROBE 2000 INSTALLATION INSTRUCTIONS

FitchTM. Instruction Manual. Includes our Basic Function CoolTouch TM Control System Looks permanent, but goes wherever you go!

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Cable Actuated Sensor Industrial User Scalable VDC Output

ACTIV8 ONE OFF. 1 Tips USER S GUIDE COMBINED RADAR OPENING AND ACTIVE INFRARED SAFETY SENSOR. 1 Description. 2 Symbols.

INSTALLATION INSTRUCTIONS AND OPERATION MANUAL. FT-EPB Series. Single Motor

RK/ RK Oxygen Detector Operator s Manual

Carbon Dioxide Sample-Draw Detector Operator s Manual

RED1. Technical Support And Installation Manual. Models ST, E1, E2, E3, E4, and 420. Approved

F6102 Installation & Operating Instructions for the Parrotuncle Owner s Installation,Manual WARNING: SHUT POWER OFF AT FUSE OR CIRCUIT BREAKER

MBCE-110/230UV Flame Sensor Module

Heimdall Radar Traffic Detector

Transcription:

IRB-HB Safety Photo Beam UL325-2010 MONITORED DEVICE Operating Instructions

CAUTIONS AND WARNINGS This product is an accessory or part of a system. Always read and follow the manufacturer s instructions for the equipment you are connecting this product to. Comply with all applicable codes and safety regulations. Failure to do so may result in damage, injury or death! 1. Read and follow all operation instructions 2. Always follow gate operator manufacturer installation instructions regarding installation of Type B1 sensor to the operator. 3. Disable the gate so it is unable to move GENERAL DESCRIPTION The IRB-HB is a safety photo beam and may be used as an external entrapment protection device type B1, non-contact sensor for use with automatic gates and doors. The light beam is near infrared and pulses at a rate of 300/second (300Hz). The IRB-HB provides a signal to the gate or door operator that the beam is not obstructed. The operating range is up to 115ft. The IRB-HB operates over a wide range of 6-35VDC. A green alignment indicator on the receiver provides status information at a glance, making set-up and alignment easy. The IRB-HB includes two selectable operating configurations providing compatibility with most operators that accommodate monitored external entrapment protection devices per UL325-2010. Refer to operator installation instructions for proper configuration selection: CONFIGURATION 1 MONITORED, HEARTBEAT 300Hz / 0Hz Intended for use with operators designed to accept a heartbeat form of monitoring, 300Hz when aligned, no obstruction, 0Hz when beam is obstructed. CONFIGURATION 2 MONITORED, HEARTBEAT 300Hz / 2Hz / 0Hz Intended for use with operators designed to accept a heartbeat form of monitoring, 300Hz when aligned, no obstruction, 2Hz when beam is obstructed, and 0Hz for a failure. IRB-HB Instructions 2

Configuration settings SW4 SW3 SW2 SW1 FUNCTION X X X OFF Configuration 1 - heartbeat output, 300Hz, 0Hz X X X ON Configuration 2 - heartbeat output, 300Hz, 2Hz, 0Hz Green status indicator IRB-HB-T (transmitter) ON Power IRB-HB-R (receiver) Flashing Blocked beam or not aligned IRB-HB-R (receiver) ON Aligned SPECIFICATIONS Operating range up to 115 ft. (35m) Detection angle 24 o Sensitivity adjustment potentiometer Power indicator Green LED Detect indicator Green LED Configuration selection switch 2 modes, pulsed (3 frequency), pulsed (2 frequency) Power protection Thermal fuse Power Supply 6 35 VDC Current 15mA (12VDC, includes TX and RX wired in parallel) Operating temperature -40 F 170 F (-40 77 C) Environmental NEMA 4X Dimensions (L x W x H) 2.3 (57mm) x 2.6 (65mm) x 3.7 (94mm) Weight TX - 0.35 lbs (159 g), RX 0.35 lbs (159 g) Connections TX-2 terminal, RX-2 terminal INSTALLATION Install the IRB-HB according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. 1. Disconnect the IRB-HB from power before installing or servicing the device. 2. Always follow the instructions of the gate operator manufacturer regarding installation of type B1 sensors on the gate operator. The instructions of the gate operator manufacturer always supersede any instructions given in this or any other instructions by EMX Industries Inc. 3. Connect the IRB-HB power supply per requirements indicated in the specification table. IRB-HB Instructions 3

4. Connect power to the terminals on the transmitter marked TX, polarity is not required. Refer to your gate operator instructions for proper photo eye connections. 5. Connect power to terminals marked POWER INPUT on the receiver, marked RX polarity is not required. Refer to your gate operator instructions for proper photo eye connections. 6. The IRB-HB is housed in a NEMA 4X enclosure. To insure the integrity of the enclosure make sure the covers are attached and closed tight using all four plastic screws provided. The wiring to the enclosure must enter via UL Listed watertight fitting such as a strain relief or watertight conduit connector. 7. The IRB-HB must be powered by Class 2 circuits only, wiring must be segregated from other circuits or insulation must be provided that is suitable for the highest voltage for those circuits. VERIFY INSTALLATION AND OPERATION Verify proper operation of the IRB-HB according to instructions from the gate operator manufacturer. The intent of External Entrapment Protection Device Type B1 non-contact sensor is to protect a person from being accidentally injured by the moving gate or door. 1. Verify that the IRB-HB transmitter and receiver in line of sight and apply power. 2. Place an obstruction (ex. hand) between the IRB-HB transmitter and receiver. The green LED on the receiver is flashing. Check the operator control board that the safety input is actuated. 3. Remove the obstruction and green LED will be on. 4. If the IRB-HB does not respond to the obstruction, lower the sensitivity by adjusting the SENSITIVITY pot counter-clockwise. 5. If the IRB-HB indicates an obstruction when there is no obstruction, check the alignment by improving the aim of the TX (transmitter). Otherwise, increase the sensitivity by adjusting the SENSITIVITY pot clockwise. 6. Follow gate/door manufacturer s installation instructions and safety checks to verify that the IRB-HB is operating properly. IRB-HB Instructions 4

TROUBLESHOOTING GUIDE Symptom Possible cause Solution Does not detect obstruction of Sensitivity too high Adjust SENSITIVITY pot beam counter-clockwise Green LED flashes continuously (indicating an obstruction when an obstruction is not present) Receiver activates but does not transmit signal to operator Signal is reflecting off another surface Sensitivity too low Transmitter does not have power Receiver does not see transmitter Faulty connection between receiver and operator control input Check area for highly reflective surfaces Adjust SENSITIVITY pot clockwise Check power source for transmitter Make sure transmitter and receiver have line of sight alignment Check wires and terminal connections to make sure they are good ORDERING INFORMATION IRB-HB Safety Photo Beam includes transmitter and receiver IRB-HD-SET Protective hoods, aluminum, gold anodized IRB-SH-SET Protective hoods, steel, gray powder-coat IRB-BR Mounting bracket, L shape IRB-SP Strain relief, water-tight IRB-S Nylon screws, set of 2 IRB-HB Instructions 5

IRB-HB Instructions 6

IRB-HB Instructions 7

4564 Johnston Parkway Cleveland, Ohio 44128 United States of America WEB http://www.emxinc.com Technical Support: (216) 834-0761 E-mail: technical@emxinc.com Sales: (216) 518-9888 Fax (216) 518-9884 E-mail salessupport@emxinc.com Revision 1.4 7.31.14 IRB-HB Instructions 8