30XAS A Air-Cooled Liquid Chillers. Nominal cooling capacity kw 50 Hz. Features and advantages. Very economical operation

Similar documents
30XAS Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features and advantages. Very economical operation

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw

30RB /30RQ

38RBS Air-Cooled Condensing Units. Nominal cooling capacity: kw. Features. Easy and fast installation

30RBY/RQY Ductable Air-Cooled Liquid Chillers/ Ductable Air-to-Water Heat Pumps PRO-DIALOG +

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module PRODUCT SELECTION DATA. Compact design

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

30RB A /30RQ

30RB/RQ 039S-160S Refrigerant HFC-410A Nominal cooling capacity kw Nominal heating capacity kw

30RB /30RQ

30RB Air-Cooled Liquid Chillers. Nominal cooling capacity 8-14 kw. Features. Quiet operation

EREBA ACCESS. Easy and fast installation Hydronic module available Compact, reliable and efficient USE RANGE CONFORMITY

61AF High-Temperature Monobloc Air-to-Water Heat Pumps with Integrated Hydronic Module. Nominal heating capacity kw.

30RB Air-Cooled Liquid Chillers PRODUCT SELECTION DATA. Easy and fast installation. Compact, reliable and efficient

AR Ductable Air-Cooled Liquid Chillers Ductable Reversible Air-to-Water Heat Pumps

38RBS Air-Cooled Condensing Units. product selection data. commercial and industrial applications. compact design.

30RB/RQ Air-Cooled Liquid Chillers/Air-to-Water Heat Pumps. product selection data

30RB/RQ 039S-160S. Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump Nominal cooling capacity: kw Nominal heating capacity: kw

30GH Air-Cooled Liquid Chillers 30GH Nominal cooling capacity kw

Unit with optional hydronic module 61WG/30WG. Nominal cooling capacity kw Nominal heating capacity kw

30RH B Nominal cooling capacity kw Nominal heating capacity kw

30KAV Variable Speed Air-cooled Screw Chiller

30XA Air-Cooled Liquid Chillers. Nominal cooling capacity kw. Features and advantages. Very economical operation

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

SPECIFICATION GUIDE NEOSYS. Air-cooled Liquid Chiller for outdoor installation (NAC) Nominal cooling capacity: 200 to 460 kw

61WG/30WG/30WGA. Water-Cooled and Condenserless Liquid Chillers Water-Sourced Heat Pumps. product selection data. 30WG optimized for cooling

30RB /30RQ

30RB Air-Cooled Liquid Chillers with Integrated Hydronic Module. Nominal cooling capacity kw. Easy and fast installation.

AQUASNAP JUNIOR 30RHV

Carrier India. Snapshots of Carrier India manufacturing facility

30GK. Air-Cooled Liquid Chillers. Nominal cooling capacity kw

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: kw 30RQ: Nominal cooling capacity:

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

30HXC Nominal cooling capacity kw

30RBS /30RQS Air-Cooled Liquid Chillers, Reversible Air-to-Water Heat Pumps. product selection data

30GX - 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-to-Water Heat Pump

30RQV NEW. Nominal cooling capacity kw Nominal heating capacity kw AIR-TO-WATER HEAT PUMPS HEATING. Easy and fast installation

MISSING 30XB / 30XBP AIR-COOLED FIXED-SPEED SCREW CHILLER PRODUCT SELECTION DATA

30RBM/30RBP AIR-COOLED SCROLL CHILLERS WITH GREENSPEED INTELLIGENCE PRODUCT SELECTION DATA

30HXC - 50 HZ. Water-Cooled Screw Compressor Liquid Chillers. Nominal cooling capacity kw

30GX 50 Hz. Air-Cooled Screw Compressor Liquid Chillers GLOBAL CHILLER. Nominal cooling capacity kw

30XW-V/30XWHV. Variable-Speed Water-Cooled Liquid Chillers/ Variable-Speed-Water-to-Water Heating Units

30XAV Variable-Speed Air-Cooled Screw Chillers. product selection data. Low energy consumption. Built in reliability and easy servicing

30RB/RQ 039S-160S Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump

30XW-PZE/30XWHPZE-A WATER-COOLED SCREW CHILLERS WATER-SOURCED SCREW HEAT PUMPS PRODUCT SELECTION DATA

30RBM/30RBP Air-Cooled Scroll Chillers with Greenspeed Intelligence PRODUCT SELECTION DATA. MAINTENANCE INSTRUCTIONS Low sound level

AQUASNAP AIR CONDITIONING MADE SIMPLE 30RA/30RH AQUASNAP LIQUID CHILLERS HEAT PUMPS

30XW-V/30XWHV. Water-cooled variable-speed screw chillers Water-sourced variable-speed screw heat pumps PRODUCT SELECTION DATA

30RBV/30RQV Inverter Air-Cooled Liquid chillers & Reversible Air to Water Heat Pumps PRODUCT SELECTION DATA INSTALLATION, OPERATION AND

SPECIFICATION GUIDE FLEXAIR. Possibility to add auxiliary heaters: Gas, Electrical Heater, Hot Water Coil Possibility to add Heat Recovery Module

HYDROCIAT LW. Use. Range. Water chillers Heat pump. Cooling capacity kw Heating capacity kw. HYDROCIAT LW, ST series

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

Renewables High-Temperature Monobloc Air-t nobloc Air oc Air o t -Wat W er Heat P ater He umps er Heat Pum mps

30RB Air-Cooled Liquid Chillers PRO-DIALOG + Nominal cooling capacity kw. Features. Quiet operation

30RB/RQ Air-Cooled Liquid Chiller Reversible Air-To-Water Heat Pump 30RB: Nominal cooling capacity: 18.8~35.5 kw 30RQ: Nominal cooling

30AW. Reversible Air to Water Heat Pump PRODUCT SELECTION DATA. Monobloc inverter. Compact, reliable and efficient. More than a Heat Pump

Neosys Product catalogue

EPCE00-10B. Powerful. air cooled. Hydronic systems EUWA*40-200K(A)X

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

SLS 1202 to With or without total heat recovery. u Air Cooled Screw Chillers. 262 to 916 kw. Engineering Data Manual

Air-Cooled Variable Speed Drive Screw Chillers. Super Efficient Super Quiet. Cooling Capacity Range kw R134a

NEOSYS. AIR TO WATER LIQUID CHILLER kw. AIR TO WATER HEAT PUMP kw. lennoxemea.com

Compact and silent Scroll compressors All-season operation

3 0 H X C A - H P 2

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

LIQUID CHILLER HEAT PUMP kw 30RB/30RQ - R410A. A Multi-Talented Performer

AIR COOLED CHILLERS FOR OUTDOOR INSTALLATION WITH INTEGRATED FREE COOLING MULTISCROLL SERIES

AQH 40 to 130. u Air-to-Water Reverse Cycle Heat Pumps. 40 to 131 kw. 45 to 141 kw. Engineering Data Manual

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only.

DYNACIAT LGN. Description. Split system Water chillers. High energy efficiency Compact and quiet Scroll compressors Brazed-plate heat exchangers

TOTAL HEAT RECOVERY MULTI-PURPOSE HEAT PUMPS

AQUACIAT LD ILD. Use. Range. Water chillers Heat pump. AQUACIAT LD series. AQUACIAT ILD series. Heat recovery. Cooling only. Cooling and heating

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 21 to 39 kw

CHGV AIR COOLED WATER CHILLER WITH HYDRAULIC EQUIPMENT AIR / WATER 47 to 78 kw

30RB B 30RB Air-Cooled Liquid Chillers. Nominal cooling capacity kw. 50 Hz

30KAV VARIABLE-SPEED SCREW LIQUID CHILLER WITH GREENSPEED TM INTELLIGENCE PRODUCT SELECTION DATA

SMART. 4,9 49,5 kw. Air cooled liquid chillers and heat pumps equipped with scroll compressor and axial fans T_SMT_0609_GB

RAH Ka AIR COOLED WATER CHILLERS WITH SCREW COMPRESSORS AND AXIAL FANS. COOLING CAPACITY FROM 387 TO 1207 kw 1 AND 2 COOLING CIRCUITS

Application guide NEOSYS kw. Air cooled liquid chiller Heat pump NEOSYS-AGU-0610-E

30HXC-HP Water-to-water Screw Heat Punp. Nominal cooling capacity: 460~1283 kw Nominal heating capacity: 498~1591 kw

BRAN Residential chillers and heat pumps. Reversible unit, air source for outdoor installation 4,81-27,2 kw <<< BACK INDEX.

.2 Section Waste Management and Disposal.

Packaged air cooled liquid chillers for outdoor installation kw. technicalcatalogue T_EGL_1012_GB

30XAS Air-Cooled Liquid Chillers

DYNACIAT LG. Use. Range. Water chillers Heat pump. DYNACIAT LGN series. DYNACIAT LG series. Hydraulic module

> HGA AIR - WATER HEAT PUMPS FOR OUTDOOR INSTALLATION. Available range. Unit description. Options. Accessories

Call us today! (800)

30RB C Series Air-Cooled Liquid Chiller

KELVIN Clim F497. Kelvin air conditioning

kw COOLING kw HEATING

AIR COOLED CHILLER FOR OUTDOOR INSTALLATION FROM 4,3 TO 35,1 kw

CMA CONDENSING UNITS FOR OUTDOOR INSTALLATION INSTALLATION AND OPERATION MANUAL

INSTALLATION, OPERATION AND M A I N T E N A N C E I N S T R U C T I O N S

AIR COOLED CHILLERS WITH SCROLL COMPRESSORS AND CENTRIFUGAL FANS

Technical Catalogue. Air-Cooled Liquid Chillers with screw compressors Nominal cooling capacity: kw 50 Hz

GPE Kc UNITS FOR 4-PIPE SYSTEMS WITH SCROLL COMPRESSORS. COOLING CAPACITY FROM 77 TO 426 kw - 2 COOLING CIRCUITS. GPE 802 Kc + CF + GP + MV + P1


NECS-N. Climaveneta Technical Bulletin. Reversible unit, air source for outdoor installation. 0202T T kw

Transcription:

Air-Cooled Liquid Chillers www.eurovent-certification.com www.certiflash.com Unit with option 279 (compressor enclosure) 30XAS A 242-482 Nominal cooling capacity 232-486 50 Hz The 30XAS Aquaforce liquid chillers are the premium solution for industrial and commercial applications where installers, consultants and building owners require optimal performances and maximum quality. The Aquaforce liquid chillers are designed to meet current and future requirements in terms of energy efficiency and operating sound levels. They use the best technologies available today: Twin-rotor screw compressor with a variable capacity valve. Single refrigerant R-134a. Low-noise generation IV Flying Bird fans made of composite material. Aluminium micro-channel heat exchangers (MCHE). Pro-Dialog+ control system. To meet to all environmental and economic requirements, the Aquaforce is available in two versions: One offers an extremely low noise level while at the same time boasting superior energy efficiency. Features and advantages Very economical operation Extremely high full load and part load energy efficiency: Eurovent energy efficiency class A to C, in accordance with EN14511-3:2011. Standardised Eurovent values in accordance with EN 14511-3:2011: EER up to 3.2 and ESEER up to 4. Twin-rotor screw compressor equipped with a highefficiency motor and a variable capacity valve that permits exact matching of the cooling capacity to the load. All aluminium condenser with high-efficiency microchannels. Flooded shell-and-tube evaporator to increase the heat exchange efficiency. Electronic expansion device permitting operation at a lower condensing pressure and improved utilisation of the evaporator heat exchange surface (superheat control). Economizer system with electronic expansion device for increased cooling capacity The other offers unequalled energy efficiency to satisfy the most stringent demands of building owners wanting to reduce operating costs to the minimum. This version is also recommended for applications in geographical zones where the air temperature is very high.

Low operating sound levels Compressor Discharge dampers integrated in the oil separator (Carrier patent). Silencer on the economiser return line. Acoustic compressor and oil separator enclosure reducing radiated noise (option). Condenser section Condenser coils in V-shape with an open angle, allowing quieter air flow across the coil Low-noise 4th generation Flying Bird fans, made of a composite material (Carrier patent) are now even quieter and do not generate intrusive low-frequency noise Rigid fan mounting preventing start-up noise (Carrier patent) Easy and fast installation Integrated hydronic module (option) Centrifugal high-pressure dual water pump, with operating time balancing and automatic changeover to the back-up pump if a fault develops Water filter protecting the water pump against circulating debris High-capacity membrane expansion tank ensures pressurisation of the water circuit Thermal insulation and aluminium protection (option) Pressure sensor to check filter pollution and for direct numerical display of the water flow rate with an estimate of the instantaneous cooling capacity at the control interface Water flow control valve Simplified electrical connections Main disconnect switch with high trip capacity Transformer to supply the integrated control circuit (400/24 V) Fast commissioning Systematic factory operation test before shipment Quick-test function for step-by-step verification of the instruments, expansion devices, fans and compressor Environmental care R-134a refrigerant Refrigerant of the HFC group with zero ozone depletion potential 30% reduction in the refrigerant charge through the use of micro-channel heat exchangers Leak-tight refrigerant circuit Reduction of leaks as no capillary tubes and flare connections are used Verification of pressure transducers and temperature sensors without transferring refrigerant charge Liquid line service valve for simplified maintenance (option) Absolute reliability Screw compressor Industrial-type screw compressor with oversized bearings and motor cooled by suction gas All compressor components are easily accessible on site minimising down-time Protection increased by an electronic board Air condenser All aluminium micro-channel heat exchangers (MCHE) with high corrosion resistance. The all aluminium design eliminates the formation of galvanic currents between aluminium and copper that cause coil corrosion in saline or corrosive environments Evaporator Thermal insulation with aluminium sheet finish for perfect resistance to external aggression (mechanical a nd UV protection) Auto-adaptive control Control algorithm prevents excessive compressor cycling (Carrier patent) Automatic compressor unloading in case of abnormally high condensing pressure. If condenser coil fouling or fan failure occurs, the Aquaforce continues to operate, but at reduced capacity Exceptional endurance tests Partnerships with specialised laboratories and use of limit simulation tools (finite element calculation) for the design of critical components. Transport simulation test in the laboratory on a vibrating table. The test is based on a military standard and equivalent to 4000 km by truck. Salt mist corrosion resistance test in the laboratory for increased corrosion resistance Control, safety 30XAS units are equipped with high-pressure safety switches with manual reset and dual safety valves on the high- and low-pressure side as standard. Each of the safety valves is mounted on a three-way valve to facilitate testing and replacement. Pro-Dialog+ control Pro-Dialog+ combines intelligence with operating simplicity. The control constantly monitors all machine parameters and precisely manages the operation of compressor, expansion devices, fans and of the evaporator water pump for optimum energy efficiency. Pro-Dialog+ interface \\MAINMENU\STATUS CAPB_T 0 % DEM_LIM 100 % SP 4.2 C CTRL_PNT -28.9 C EMSTOP dsable Circuit B Total Capacity START/STOP PRO-DIALOG+ Energy management Seven-day internal time schedule clock: permits chiller on/off control and operation at a second set point Set point reset based on the outside air temperature or the return water temperature or on the water heat exchanger delta T Master/slave control of two chillers operating in parallel with operating time equalisation and automatic changeover in case of a unit fault (accessory) Change-over based on the outside air temperature Integrated features Night mode: capacity and fan speed limitation for reduced noise level With hydronic module: water pressure display and water flow rate calculation Ease-of-use The new backlighted LCD interface includes a manual control potentiometer to ensure legibility under any lighting conditions. The information is displayed clearly in English, French, German, Italian and Spanish (for other languages please consult Carrier). The Pro-Dialog+ navigation uses intuitive tree-structure menus. They are user-friendly and permit quick access to the principal operat-ing parameters: compressor operating, suction/discharge pressure, compressor operating hours, set point, air temperature, entering/leaving water temperature. ENTER 2

Remote management (standard) Aquaforce is equipped with an RS485 serial port that offers multiple remote control, monitoring and diagnostic possibilities. Carrier offers a vast choice of control products, specially designed to control, manage and supervise the operation of an air conditioning system. Please consult your Carrier representative for more information. Aquaforce also communicates with other building management systems via optional communication gateways. A connection terminal allows remote control of the Aquaforce by wired cable: Start/stop: opening of this contact will shut down the unit Dual set-point: closing of this contact activates a second set-point (example: unoccupied mode) Demand limit: closing of this contact limits the maximum chiller capacity to a predefined value Heat reclaim (option): closing of this contact allows heat reclaim mode operation Water pump 1 and 2 control (not available for hydronic module option 116): these outputs control the contactors of one or two evaporator water pumps Operation indication: this volt-free contact indicates that the chiller is operating (cooling load) or that it is ready to operate (no cooling load) Alert indication: this volt-free contact indicates the necessity to carry out a maintenance operation or the presence of a minor fault Alarm indication: this volt-free contact indicates the presence of a major fault that has led to the shut-down of one or several refrigerant circuits Remote management (EMM option 156) The Energy Management Module offers extended remote control possibilities: Room temperature: permits set-point reset based on the building indoor air temperature (with Carrier thermostat) Set point reset: ensures reset of the cooling set-point based on a 4-20 ma or 0-5 V signal Demand limit: permits limitation of the maximum chiller power or current based on a 0-10 V signal Demand limit 1 and 2: closing of these contacts limits the maximum chiller power or current to two predefined values. User safety: this contact can be used for any customer safety loop; opening of the contact generates a specific alarm Ice storage end: when ice storage has finished, this input permits return to the second set-point (unoccupied mode) Time schedule override: closing of this contact cancels the time schedule effects Out of service: this signal indicates that the chiller is completely out of service Chiller capacity: this analogue output (0-10 V) gives an immediate indication of the chiller capacity 06T screw compressor The Carrier 06T screw compressors benefit from Carrier s long experience in the development of twin-rotor screw compressors. The compressor is equipped with bearings with oversized rollers, oil pressure lubricated for reliable and durable operation, even at maximum load.a variable control valve controlled by the oil pressure permits infinitely variable cooling capacity. This system allows optimal adjustment of the compressor cooling capacity and ensures exceptionally high stability of the chilled water leaving temperature. Among the other advantages: if a fault occurs e.g. if the condenser is fouled or at very high outside temperature, the compressor does not switch off, but continues operation with a reduced capacity (unloaded mode). The compressor is equipped with a separate oil separator that minimises the amount of oil in circulation in the refrigerant circuit and with its integrated silencer considerably reduces discharge gas pulsations for much quieter operation. 3

All-aluminium micro-channel heat exchanger (MCHE) Already utilised in the automobile and aeronautical industries for many years, the MCHE micro-channel heat exchanger used in the Aquaforce is entirely made of aluminium. This one-piece concept significantly increases its corrosion resistance by eliminating the galvanic currents that are created when two different metals (copper and aluminium) come into contact in traditional heat exchangers. Unlike traditional heat exchangers the MCHE heat exchanger can be used in moderate marine and urban environments (Carrier recommendation). From an energy efficiency point-of-view the MCHE heat exchanger is approximately 10% more efficient than a traditional coil and allows a 30% reduction in the amount of refrigerant used in the chiller. The low thickness of the MCHE reduces air pressure losses by 50% and makes it susceptible to very little fouling (e.g. by sand). Cleaning of the MCHE heat exchanger is very fast using a high-pressure washer. 4

Options Options No. Description Advantages Use Corrosion protection, traditional 2B Factory application of Blygold Polual treatment on the Improved corrosion resistance, recommended for 30XAS 242-482 coils (for the Middle East only) copper/aluminium coils industrial, rural and marine environments Corrosion protection, traditional 3A Fins made of pre-treated aluminium (polyurethane Improved corrosion resistance, recommended for 30XAS 242-482 coils (for the Middle East only) and epoxy) moderate marine and urban environments Unit equipped for air discharge 10 Fans with available pressure equipped with discharge Facilitates connection to the discharge ducts 30XAS 242-482 ducting connection flanges IP 54 control box 20A Increased leak tightness of control boxes Increased control box protection 30XAS 242-482 Grilles 23 Metal grilles on the unit front, rear and sides Enhanced aesthetics, protection against intrusion to 30XAS 242-482 the unit interior Enclosure panels 23A Side panels at each end of the coil Enhanced aesthetics 30XAS 242-482 Winter operation 28 Fan speed control via frequency converter Stable unit operation when the air temperature is 30XAS 242-482 between -10 C and -20 C Evaporator frost protection 41A Resistance heater on the evaporator Evaporator frost protection down to -20 C outside 30XAS 242-482 temperature Evaporator and hydronic 41B Resistance heater on the evaporator and the Evaporator and hydronic module frost protection 30XAS 282-482 module frost protection hydronic module down to -20 C outside temperature Heat reclaim 50 Complete recovery of the heat rejected by the Free hot-water production as well as cold-water 30XAS 242-482 condenser production Master/slave operation 58 Additional leaving water temperature sensor kit for on-site installation, permitting master/slave operation of two chillers connected in parallel. Optimised operation of two chillers connected in parallel with operating time balancing. 30XAS 242-482 Service valve 92 Shut-off valves on the compressor suction piping, the Simplified maintenance 30XAS 242-482 economiser line, the compressor discharge piping and at the evaporator inlet Discharge valve 93A Shut-off valves on the compressor discharge piping Simplified maintenance 30XAS 242-482 High-pressure dual-pump 116C See hydronic module chapter Easy and fast installation, operating safety 30XAS 282-482 hydronic module High energy efficiency 119 Improved condenser performance Energy cost reduction, full load operation at higher 30XAS 242-482 air temperatures JBus gateway 148B Two-directional communications board, complies Easy connection by communication bus to a 30XAS 242-482 with JBus protocol building management system BacNet gateway 148C Two-directional communications board, complies Easy connection by communication bus to a 30XAS 242-482 with BacNet protocol building management system LON gateway 148D Two-directional communications board, complies Easy connection by communication bus to a 30XAS 242-482 with LON protocol building management system Energy Management Module EMM 156 See chapter Energy Management Module Easy connection by wired connection to a building management system 30XAS 242-482 Dual relief valve installed with three-way valve 194 Three-way valve upstream of the safety valves on the evaporator and the oil separator Valve replacement and inspection facilitated without refrige-rant loss. Conforms to European standard EN 378/BGVD4 30XAS 242-342 Russian code compliance 199 GOST certification Conformance with Russian regulations (GOST) 30XAS 242-482 Australian code compliance 200 Pressure vessels approved in accordance with the Conformance with Australian regulations 30XAS 242-482 Australian code Traditional coils (Cu/Al) (for the 254 Coils made of copper tubes with aluminium fins Possibility to add specialised condenser treatment 30XAS 242-482 Middle East only) Traditional coils (Cu/Al) without 255 Coils made of copper tubes with aluminium fins Possibility to add specialised condenser treatment. 30XAS 242-482 slots (for the Middle East only) without slots Suction piping insulation 256 Thermal insulation of the suction piping with flexible, Prevents condensation on the suction piping 30XAS 242-482 anti-uv insulant Low sound level 257 Compressor sound enclosure and sound insulation Reduced sound emissions 30XAS 242-482 of main noise sources Very low sound level 258 Compressor sound enclosure and enhanced sound Reduced sound emissions 30XAS 242-482 insulation of main noise sources MCHE anti-corrosion 263 Carrier factory treatment of the MCHE heat The Super Enviro-Shield option was developed to 30XAS 242-482 protection exchanger for applications in aggressive environments extend the application range of MCHE heat exchangers in severe environmental conditions: this option is compulsory in industrial and coastal environments. Welded Victaulic evaporator 266 Piping to be welded with Victaulic connection Ease-of-installation 30XAS 242-482 water connection Compressor enclosure 279 Compressor sound enclosure Reduced sound emissions 30XAS 242-482 Evaporator with aluminium jacket 281 Evaporator aluminium sheet for thermal insulation protection. Improved resistance to aggressive climate conditions.. 30XAS 242-482 5

Hydronic module (option 116C) Typical hydronic circuit diagram 15 1 2 16 17 C 1 2 9 9 D A 13 9 9 4 12 3 14 5 7 10 Legend Components of unit and hydronic module A Pressure sensor (A-B = p evaporator) B Pressure sensor C Pressure sensor (C-D = p water filter) D Pressure sensor 1 Victaulic screen filter 2 Expansion tank 3 Safety valve 4 Available pressure pump 5 Drain valve 6 Water flow control valve 7 Evaporator 8 Evaporator defrost heater (option) 9 Hydronic module defrost heater 10 Air vent (evaporator) 11 Water purge (evaporator) 12 Expansion compensator (flexible connections) 13 Flow switch 14 Water temperature sensor 8 System components (supplied by customer) 15 Air vent 16 Flexible connection 17 Shut-down valves 18 Charge valve Hydronic module (option) 16 17 6 9 B 11 18 14 Available static pressure, kpa Available static system pressure for unit with hydronic module (option 116C) 400 350 300 250 200 150 100 Legend 1. 30XAS 282 2. 30XAS 342 3. 30XAS 442 4. 30XAS 482 Electrical data (option 116C) The pumps that are factory-installed in these units have motors with efficiency class IE2. The additional electrical data required by regulation 640/2009 is given in the installation, operation and maintenance manual. This regulation concerns the application of directive 2005/32/EC on the eco-design requirements for electric motors. 50 3 5 7 9 11 13 15 17 19 21 23 25 27 29 31 Water flow rate, l/s Fan with available pressure (option 10) This option allows a duct connection at the discharge side of the condenser fan. The unit is supplied with axial fans with a speed of 15.8 r/s (option 119), each equipped with a duct connection frame. The chiller can operate up to 60 Pa with reduced performance. Selection example The base capacities are those of option 119 (page 6 of this document). To obtain capacities at various pressure drops use the correction factors in the table opposite. Selection at Eurovent conditions 30XAS options 119 + 10 Sizes 282-482 Fan pressure drop, Pa 0 20 40 60 Correction factor Air flow % l/s 1-3.5-7.5-12.1 Cooling capacity % 0-0.5-1.0-1.5 EER % / 0-1.5-3.5-5.0 Power input % 0 +1.0 +2.5 +3.5 Example 30XAS 282 with 40 Pa pressure drop Values for option 119 at the following conditions: 35 C outside air temperature 12/7 C entering/leaving water temperature 30XAS 282 0 Pa Correction factor, % 40 Pa Air flow l/s 22569-7.5 20876 Cooling capacity 280-1 277 EER / 3.17-3.5 3,06 Power input 88 +3.5 90 6

Total heat reclaim (option 50) Suitable for heating, domestic hot water preparation, agriculture and food industry, industrial processes and other hot-water requirements. With the total heat reclaim option it is possible to reduce the energy consumption bill considerably compared to conventional heating equipment such as fossil fuel boilers or electric water tanks. Operating principle If hot water production is required, the compressor discharge gases are directed towards the heat reclaim condenser. The refrigerant releases its heat to the hot water that leaves the condenser at a temperature of up to 60 C. In this way 100% of the heat rejected by the liquid chiller can be used to produce hot water. When the demand for heat is satisfied, the hot gas is again directed towards the air condenser where the heat is rejected to the outside air by the fans. Hot water temperature control is ensured by the chiller Pro-Dialog+ control. Note: Heat reclaim is only possible, if the unit produces cold water at the same time. Condenser water temperature ( C) Minimum Maximum Entering temperature at start-up 12.5* 55 Entering temperature during operation 20 55 Leaving temperature during operation 25 60 Evaporator water temperature ( C) Entering temperature at start-up - 45 Entering temperature during operation 6.8 21 Leaving temperature during operation 3.3 15 * The entering water temperature at start-up must not fall below 12.5 C. For installations with a lower temperature a three-way valve must be used. Note: If the evaporator leaving water temperature is below 4 C, a glycol-water solution or the frost protection option must be used. In part-load operation, the limitation of the condenser leaving water temperature is due to the operating range of the screw compressor. If the condenser leaving water temperature is above the limit value given in the curves on the right, the unit will automatically change over to the mode without heat recovery: Condenser leaving water temperature, C Maximum condenser leaving water temperature, C 6 5 6 0 5 5 5 0 4 5 4 0 3 5 3 0 2 5 2 0 0 5 1 0 1 5 Evaporator leaving water temperature, C Full load Part load limit, approx. 60% Minimum load limit, approx. 30% Part load operating limits (evaporator leaving water temperature = 7 C) 60 55 50 45 40 100 90 80 70 Unit load, % 60 50 40 30 Physical data, option 50 These are the same as for the standard unit except: 30XAS heat reclaim mode 282 342 442 482 Cooling capacity* 278 329 428 475 Heating capacity* 349 411 538 599 Total power input (unit)* 77.7 90.2 120.6 136.0 Total energy efficiency ratio (EER) / 3.58 3.65 3.55 3.49 Total coefficient of performance (COP) / 4.49 4.56 4.46 4.40 Operating weight** kg 3260 3320 4190 4280 Refrigerant charge kg 73 78 90 95 Heat reclaim condenser Flooded shell-and-tube condenser Water volume l 55 55 68 68 Water connection Victaulic Diameter inch 4 4 4 4 Outside diameter mm 114.3 114.3 114.3 114.3 * Nominal conditions: Entering/leaving water temperature: evaporator 12 C/7 C; heat reclaim condenser: 40 C/45 C; evaporator and heat reclaim condenser fouling factor = 0 m 2 K/. Gross performances, not in accordance with EN14511-3:2011. These performances do not take into account the correction for the proportional heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. ** Weights are for guidance only 7

Physical data 30XAS 242 282 342 442 482 Air conditioning application as per EN14511-3:2011* Nominal cooling capacity, standard unit 232 284 334 430 467 EER / 2.76 3.00 3.08 2.93 2.87 Eurovent class cooling C B B B C ESEER / 3.78 3.93 3.99 3.87 3.96 Air conditioning application** Nominal cooling capacity, standard unit 233 285 335 432 469 EER / 2.78 3.03 3.11 2.96 2.91 ESEER / 3.85 4.01 4.09 3.97 4.07 Air conditioning application as per EN14511-3:2011* Nominal cooling capacity, unit with option 119*** 245 285 345 461 486 EER / 2.97 3.15 3.24 3.15 3.09 Eurovent class cooling B A A A B ESEER / 3.69 3.69 3.80 3.75 3.79 Air conditioning application** Nominal cooling capacity, unit with option 119*** 245 286 346 462 488 EER / 2.99 3.18 3.28 3.18 3.13 ESEER / 3.75 3.76 3.90 3.84 3.89 Operating weight**** kg 2390 2810 2870 3630 3720 With option 116C*** kg - 3070 3190 3990 4150 With options 254 or 255*** kg 2540 3060 3140 3950 4070 Sound levels Standard unit Sound power level db(a) 99 98 98 103 102 Sound pressure level at 10 m db(a) 67 66 66 70 70 Standard unit + option 279*** Sound power level db(a) 94 94 93 97 96 Sound pressure level at 10 m db(a) 62 62 61 65 64 Standard unit + option 257*** Sound power level db(a) 92 92 91 95 94 Sound pressure level at 10 m db(a) 60 60 59 62 61 Standard unit + option 258*** Sound power level db(a) 89 89 88 92 91 Sound pressure level at 10 m db(a) 57 57 56 59 58 High energy efficiency unit (option 119)*** Sound power level db(a) 96 96 96 98 98 Sound pressure level at 10 m db(a) 64 64 63 66 66 High energy efficiency unit (option 119)*** + option 257*** Sound power level db(a) 95 95 95 97 97 Sound pressure level at 10 m db(a) 63 62 62 65 64 Dimensions Length mm 2410 3604 3604 4798 4798 Depth mm 2253 2253 2253 2253 2253 Height mm 2297 2297 2297 2297 2297 Compressor 06T semi-hermetic screw compressor, 50 r/s Refrigerant**** R-134a, one circuit Refrigerant charge kg 60 72 73 83 88 Refrigerant charge option 254/255*** kg 85 95 105 120 130 Capacity control PRO-DIALOG+, electronic expansion valve (EXV) Minimum capacity % 30 30 30 30 30 Condensers All aluminium micro-channel heat exchanger Condenser fans Axial Flying Bird IV fans with rotating shroud - standard speed = 11.7 r/s; speed with option 119 = 15.7 r/s Standard units and units with option 119-254*** Quantity 4 5 6 7 8 Total air flow, standard unit l/s 13667 17083 20500 23917 27333 Total air flow - unit with option 119*** l/s 18055 22569 27083 31597 36111 Evaporator Flooded shell-and-tube type Water content l 53 53 53 75 75 Without hydronic module Diameter 5 in, outside diameter 141.3 mm, Victaulic water inlet and outlet connections Max. water-side pressure kpa 1000 1000 1000 1000 1000 With hydronic module (option 116C)*** Diameter 4 in, outside diameter 114.3 mm, Victaulic water inlet and outlet connections Expansion tank volume l - 50 50 50 50 Max. water-side pressure kpa - 400 400 400 400 Chassis paint colour Colour code: RAL7035 * Eurovent-certified performances in accordance with standard EN14511-3:2011. Cooling mode conditions: evaporator water entering/leaving temperature 12 C/7 C, outside air temperature 35 C. evaporator fouling factor 0 m 2 K/W ** Gross performances, not in accordance with EN14511-3:2011. These performances do not take into account the correction for the proportional heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. Cooling mode conditions: evaporator water entering/leaving temperature 12 C/7 C, outside air temperature 35 C. evaporator fouling factor 0 m 2 K/W *** Options: 116C = high-pressure dual-pump hydronic module; 119 = high energy efficiency units; 254 = units with copper/aluminium coils with slots; 255 = units with copper/aluminium coils with plain fins; 257 = low sound level; 258 = very low sound leve; 279 = compressor enclosure. **** Weights are guidelines only. The refrigerant charge is also given on the unit nameplate. 10-12 W - In accordance with ISO 9614-1 and certified by Eurovent. Average sound pressure level, unit in a free field on a reflective surface. In accordance with ISO 9614-1 (10-12 W). For information, calculated from the sound power level Lw(A) Note: Option 119 (high energy efficiency) can be used together with options 254 and 255. Contact your Carrier representative to obtain the performances. 8

Electrical data 30XAS 242 282 342 442 482 Power circuit Nominal power supply V-ph-Hz 400-3-50 Voltage range V 360-440 Maximum supply cable section mm 2 2 x 150 2 x 95 2 x 150 2 x 150 2 x 240 Short-circuit stability current (TN system)* ka 38 50 50 50 50 Control circuit 24 V via internal transformer Start-up current** A 303 388 388 587 587 Standard unit Cosine Phi maximum*** 0.89 0.88 0.88 0.87 0.87 Cosine Phi nominal**** 0.85 0.85 0.86 0.84 0.85 Maximum power input 101 113 134 184 213 Nominal current draw**** A 141 153 174 258 278 Maximum current draw (Un) A 165 185 218 305 353 Maximum current draw (Un -10%)*** A 180 198 231 324 375 High energy efficiency unit (option 119) Cosine Phi maximum*** 0.88 0.88 0.88 0.87 0.87 Cosine Phi nominal**** 0.84 0.85 0.85 0.83 0.84 Maximum power input 105 118 139 190 221 Nominal current draw**** A 141 153 175 254 271 Maximum current draw (Un) A 172 194 229 318 368 Maximum current draw (Un -10%)*** A 187 207 242 337 390 * ka eff: efficiency value: rms for English version ** Instantaneous start-up current (locked rotor current in star connection of the compressor). *** Values obtained at operation with maximum unit power input. **** Values obtained at standard Eurovent unit operating conditions: air 35 C, water 12/7 C. Values obtained at operation with maximum unit power input. Values given on the unit name plate. Note: Motor and fan electrical data if the unit operates at Eurovent conditions (motor ambient temperature 50 C): 1.9 A Start-up current: 8.4 A Power input: 760 W Electrical data notes and operating conditions for 30XAS units: 30XAS 242-482 units have a single power connection point located immediately upstream of the main disconnect switch. The control box includes the following standard features: One general disconnect switch Starter and motor protection devices for the compressor, the fans and the pump Control devices Field connections All connections to the system and the electrical installations must be in full accordance with all applicable local codes. The Carrier 30XAS units are designed and built to ensure conformance with these codes. The recommendations of European standard EN 60 204-1 (corresponds to IEC 60204-1) (machine safety - electrical machine compo-nents - part 1: general regulations) are specifically taken into account, when designing the electrical equipment. IMPORTANT Generally the recommendations of IEC 60364 are accepted as compliance with the requirements of the installation directives. Conformance with EN 60 204 is the best means of ensuring compliance with the Machines Directive 1.5.1. Annex B of EN 60204-1 describes the electrical characteristics used for the operation of the machines. The operating environment for the 30XAS units is specified below: 1. Environment* Environment as classified in EN 60 721 (corresponds to IEC 60721) : outdoor installation* ambient temperature range: 20 C to +55 C, class 4K4H* altitude: 2000 m (see note for table 4.3 in the IOM) indoor installation* presence of hard solids, class 4S2* (no significant dust present) presence of corrosive and polluting substances, class 4C2 (negligible) 2. Power supply frequency variation: ± 2 Hz. 3. The neutral (N) line must not be connected directly to the unit (if necessary use a transformer). 4. Overcurrent protection of the power supply conductors is not provided with the unit. 5. The factory installed disconnect switch(es)/circuit breaker(s) is (are) of a type suitable for power interruption in accordance with EN 60947-3 (corresponds to IEC 60947-3). 6. The units are designed for simplified connection on TN(s) networks (IEC 60364). For IT networks derived currents may interfere with network monitoring elements, and it is recommended to create an IT type divider for the system units that require this and/or a TN type divider for Carrier units. Please consult the appropriate local organisations to define the monitoring and protection elements and carry out the electrical installation. NOTE: If particular aspects of an actual installation do not conform to the conditions described above, or if there are other conditions which should be considered, always contact your local Carrier representative. * The required protection level for this class is IP43BW (according to reference document IEC 60529). All 30XAS units are protected to IP44CW and fulfil this protection condition. 9

Part load performances With the rapid increase in energy costs and the care about environmental impacts of electricity production, power consumption of air conditioning equipment has become an important topic. The energy efficiency of a liquid chiller at full load is rarely representative of the actual performance of the units, as on average a chiller works less than 5% of the time at full load. IPLV (in accordance with AHRI 550/590) The IPLV (integrated part load value) allows evaluation of the average energy efficiency based on four operating conditions defined by the AHRI (Air Conditioning, Heating and Refrigeration Institute). The IPLV is the average weighted value of the energy efficiency ratios (EER) at different operating conditions, weighted by the operating time. IPLV (integrated part load value) Load % Air temperature C Energy efficiency Operating time % 100 35 EER 1 1 75 26.7 EER 2 42 50 18.3 EER 3 45 25 12.8 EER 4 12 IPLV = EER 1 x 1% + EER 2 x 42% + EER 3 x 45% + EER 4 x 12% The heat load of a building depends on many factors, such as the outside air temperature, the exposure to the sun and the building occupancy. Consequently it is preferable to use the average energy efficiency, calculated at several operating points that are representative for the unit utilisation. ESEER (in accordance with EUROVENT) The ESEER (European seasonal energy efficiency ratio) permits evaluation of the average energy efficiency at part load, based on four operating conditions defined by Eurovent. The ESEER is the average value of energy efficiency ratios (EER) at different operating conditions, weighted by the operating time. ESEER (European seasonal energy efficiency ratio) Load % Air temperature C Energy efficiency Operating time % 100 35 EER 1 3 75 30 EER 2 33 50 25 EER 3 41 25 20 EER 4 23 ESEER = EER 1 x 3% + EER 2 x 33% + EER 3 x 41% + EER 4 x 23% 30XAS 242 282 342 442 482 Standard units IPLV / 4.23 4.55 4.72 4.55 4.60 ESEER / 3.78 3.93 3.99 3.87 3.96 High-efficiency units (option 119) IPLV / 4.16 4.23 4.44 4.36 4.41 ESEER / 3.69 3.69 3.80 3.75 3.79 ESEER Calculations according to standard performances (in accordance with EN14511-3:2011) and certified by Eurovent. IPLV Calculations according to standard performances (in accordance with AHRI 550-590) 10

Sound spectrum 30XAS - standard unit Octave bands, Hz Sound power 125 250 500 1k 2k 4k levels 242 db 85 94 97 95 89 84 db(a) 99 282 db 88 93 98 93 88 80 db(a) 98 342 db 86 94 95 94 89 87 db(a) 98 442 db 89 98 98 100 93 89 db(a) 103 482 db 89 94 97 100 91 85 db(a) 102 30XAS - standard unit with option 257* Octave bands, Hz Sound power 125 250 500 1k 2k 4k levels 242 db 85 94 91 85 79 74 db(a) 92 282 db 88 93 93 83 78 71 db(a) 92 342 db 86 94 90 85 79 77 db(a) 91 442 db 89 98 92 89 82 79 db(a) 95 482 db 89 94 92 90 81 76 db(a) 94 30XAS - unit with option 279* Octave bands, Hz Sound power 125 250 500 1k 2k 4k levels 242 db 85 94 94 88 82 76 db(a) 94 282 db 88 93 96 86 81 73 db(a) 94 342 db 86 94 92 87 82 79 db(a) 93 442 db 89 98 95 93 86 81 db(a) 97 482 db 89 94 95 93 84 78 db(a) 96 30XAS - unit with option 258* Octave bands, Hz Sound power 125 250 500 1k 2k 4k levels 242 db 85 91 88 83 76 71 db(a) 89 282 db 88 90 89 82 76 68 db(a) 89 342 db 86 91 85 83 77 74 db(a) 88 442 db 89 96 89 87 78 75 db(a) 92 482 db 89 91 89 87 78 73 db(a) 91 30XAS - unit with option 119* Octave bands, Hz Sound power 125 250 500 1k 2k 4k levels 242 db 96 95 98 96 90 85 db(a) 100 282 db 96 95 99 94 89 82 db(a) 99 342 db 97 95 96 95 90 88 db(a) 99 442 db 98 99 98 101 94 89 db(a) 103 482 db 98 96 98 101 92 87 db(a) 103 30XAS - unit with option 119 + 257* Octave bands, Hz Sound power 125 250 500 1k 2k 4k levels 242 db 96 95 93 89 84 80 db(a) 95 282 db 96 95 94 89 84 80 db(a) 95 342 db 97 95 92 90 85 82 db(a) 95 442 db 98 99 94 92 86 83 db(a) 97 482 db 98 96 94 93 86 82 db(a) 97 30XAS - unit with option 119 + 279* Octave bands, Hz Sound power 125 250 500 1k 2k 4k levels 242 db 96 95 95 91 85 81 db(a) 96 282 db 96 95 96 90 85 80 db(a) 96 342 db 97 95 94 91 86 82 db(a) 96 442 db 98 99 96 94 88 84 db(a) 98 482 db 98 96 96 94 87 83 db(a) 98 * Options: 119 = high energy efficiency units; 257 = low sound level; 258 = very low sound level; 279 = compressor enclosure 11

Operating limits Evaporator water temperature C Minimum Maximum Water entering temperature at start-up - 45* Water entering temperature during operation 6.8 21 Water leaving temperature during operation 3.3 15 Note: If the leaving water temperature is below 4 C, a glycol/water solution or the frost protection option must be used. Condenser air temperature C Minimum Maximum Storage -20 68 Operation: Standard unit -10 55** With option 28: winter operation -20 55** With option 119: high energy efficiency*** -10 55**** Evaporator water flow rate (l/s) 30XAS Minimum Maximum* 242 3.2 30.7 282 3.7 30.7 342 4.4 30.7 442 5.8 41.0 482 6.5 41.0 * The maximum water flow rate corresponds to a pressure drop of 100 kpa. Note: If the air temperature is below 0 C, a glycol/water solution or the frost protection option must be used. * Based on the installation type and the air temperature ** Part load, based on the water temperature *** Recommended for operation above 46 C **** Part-load operation Operating range 30XAS standard unit 30XAS high energy efficiency unit or option 119 Air entering temperature, C Air entering temperature, C Evaporator leaving water temperature, C Evaporator leaving water temperature, C Legend Operating range, unirt equipped with option 28 "Winter operation" Below 0 C air temperature the unit must either be equipped with the evaporator frost protection option (41A or 41B), or the water loop must be protected against frost by using a frost protection solution (by the installer). Part load average 12

Dimensions/clearances 30XAS 242 30XAS 282-342 30XAS 442-482 1 2 Legend All dimensions are given in mm. Required clearances for maintenance and air flow Recommended space for evaporator tube removal Water inlet Water outlet Air outlet do not obstruct Power supply connection C Control circuit connection Note: Drawings are not contractually binding. Before designing an installation, consult the certified dimensional drawings, available on request 13

Dimensions/clearances 30XAS 282-342 - heat reclaim unit (option 50) Specific elements for option 50 Attention: The Victaulic flange sleeves of the condenser are not installed, but supplied with the unit. The sealing joints are in the control box. The temperature sensors and the condenser flow switch are wired and fixed in the machine. They must be installed as described in the chapter Condenser water connections in the Installation Manual. Note: Drawings are not contractually binding. Before designing an installation, consult the certified dimensional drawings supplied with the unit or available on request. 30XAS 442-482 - heat reclaim unit (option 50) For the positioning of the fixing points, weight distribution and centre of gravity coordinates please refer to the dimensional drawings. 1 2 Legend All dimensions are given in mm. Required clearances for maintenance and air flow Recommended space for evaporator tube removal Water inlet Water outlet Air outlet do not obstruct Power supply connection C Control circuit connection 14

Cooling capacities in accordance with EN14511-3 : 2011 SI system 30XAS standard unit and unit with high energy efficiency (option 119) Condenser entering air temperature, C 20 25 30 35 40 46 LWT Qc EER q Δp Qc EER q Δp Qc EER q Δp Qc EER q Δp Qc EER q Δp Qc EER q Δp C / l/s kpa / l/s kpa / l/s kpa / l/s kpa / l/s kpa / l/s kpa 30XAS standard unit 242 5 243 3.88 11.8 16 236 3.46 11.4 15 227 3.08 11.0 14 219 2.73 10.6 13 209 2.40 10.1 12 197 2.05 9.5 12 282 296 4.18 13.5 21 287 3.72 13.1 20 277 3.30 12.7 19 266 2.92 12.2 17 255 2.58 11.7 16 241 2.20 11.0 14 342 348 4.28 16.4 31 336 3.81 15.8 29 325 3.39 15.3 27 312 2.99 14.7 25 299 2.63 14.1 23 281 2.23 13.2 20 442 451 4.09 21.1 32 436 3.65 20.4 30 421 3.24 19.7 28 405 2.87 18.9 26 388 2.52 18.2 24 367 2.14 17.2 22 482 488 4.04 23.0 37 472 3.61 22.2 35 455 3.20 21.4 33 437 2.83 20.5 30 417 2.48 19.6 28 392 2.10 18.5 25 242 7 257 3.91 12.4 18 249 3.50 12.0 17 240 3.11 11.6 15 231 2.76 11.2 14 222 2.44 10.7 13 202 2.13 9.8 12 282 314 4.27 14.4 24 304 3.81 13.9 22 294 3.38 13.5 21 283 3.00 12.9 19 271 2.64 12.4 18 256 2.26 11.7 16 342 369 4.38 17.4 35 357 3.91 16.9 32 345 3.47 16.3 30 331 3.07 15.6 28 317 2.70 14.9 26 299 2.29 14.1 23 442 479 4.17 22.4 35 463 3.72 21.7 33 446 3.31 20.9 31 429 2.92 20.1 29 410 2.57 19.2 27 380 2.21 17.8 23 482 519 4.12 24.5 41 502 3.67 23.6 39 483 3.25 22.8 36 464 2.87 21.9 34 444 2.52 20.9 31 418 2.14 19.7 28 242 10 278 3.96 13.5 20 269 3.54 13.0 19 260 3.15 12.6 18 250 2.80 12.1 16 239 2.48 11.6 15 212 2.23 10.3 12 282 343 4.39 15.8 28 332 3.92 15.2 26 320 3.49 14.7 24 308 3.10 14.1 22 295 2.74 13.6 21 279 2.34 12.8 18 342 404 4.51 19.1 41 391 4.03 18.5 38 377 3.59 17.8 35 362 3.18 17.1 33 346 2.79 16.3 30 326 2.37 15.4 27 442 522 4.27 24.5 41 504 3.82 23.7 38 485 3.39 22.8 36 466 3.00 21.9 33 446 2.64 20.9 30 389 2.33 18.2 24 482 567 4.24 26.8 48 548 3.78 25.9 45 527 3.35 24.9 42 506 2.96 23.9 39 483 2.60 22.8 36 421 2.28 19.9 28 30XAS high energy efficiency unit (option 119) 242 5 253 4.07 11.9 16 246 3.66 11.6 16 238 3.26 11.2 15 229 2.90 10.8 14 220 2.57 10.3 12 209 2.21 9.8 12 282 294 4.26 13.8 22 285 3.82 13.4 21 276 3.42 13.0 20 266 3.05 12.5 18 256 2.70 12.0 17 243 2.33 11.4 15 342 356 4.38 16.8 32 345 3.93 16.2 31 334 3.51 15.7 29 321 3.12 15.1 26 308 2.76 14.5 24 291 2.36 13.7 22 442 478 4.26 21.7 34 463 3.83 21.1 32 448 3.43 20.4 30 432 3.06 19.6 28 415 2.71 18.9 26 394 2.32 17.9 24 482 504 4.21 23.7 40 489 3.80 23.0 37 473 3.41 22.2 35 456 3.04 21.4 33 438 2.70 20.6 31 414 2.32 19.5 28 242 7 268 4.14 12.6 18 260 3.72 12.3 17 252 3.32 11.9 16 243 2.96 11.4 15 234 2.63 11.0 14 222 2.26 10.4 13 282 313 4.38 14.7 25 303 3.94 14.3 23 293 3.52 13.8 22 283 3.14 13.3 20 272 2.79 12.8 19 258 2.41 12.2 17 342 380 4.53 17.9 36 368 4.06 17.3 34 355 3.63 16.7 32 342 3.23 16.1 30 328 2.86 15.5 27 311 2.45 14.6 24 442 508 4.38 23.1 37 492 3.94 22.4 35 476 3.53 21.7 33 458 3.14 20.9 31 440 2.78 20.0 29 418 2.39 19.0 26 482 535 4.29 25.2 44 518 3.86 24.4 41 501 3.45 23.6 39 483 3.08 22.8 36 464 2.73 21.9 34 440 2.35 20.7 31 242 10 292 4.23 13.7 21 283 3.80 13.3 20 273 3.40 12.9 19 264 3.03 12.4 17 253 2.69 11.9 16 240 2.32 11.3 14 282 342 4.56 16.2 29 332 4.10 15.7 27 321 3.68 15.1 26 310 3.28 14.6 24 298 2.92 14.0 22 282 2.52 13.3 20 342 417 4.74 19.7 43 404 4.26 19.1 41 390 3.81 18.4 38 376 3.40 17.8 35 361 3.01 17.0 32 341 2.58 16.1 29 442 557 4.54 25.4 43 539 4.09 24.6 41 520 3.66 23.7 38 501 3.26 22.8 36 481 2.89 21.9 33 455 2.49 20.8 30 482 586 4.46 27.7 51 567 4.01 26.8 48 547 3.59 25.8 45 526 3.19 24.8 42 505 2.83 23.8 39 477 2.42 22.5 35 Legend LWT Leaving water temperature, C Qc Cooling capacity, EER Energy efficiency ratio, / q Evaporator water flow rate, l/s Δp Evaporator pressure drop, kpa Application data Standard units, refrigerant: R-134a Evaporator entering/leaving water temperature difference: 5 K Evaporator fluid: chilled water Fouling factor: 0.18 x 10-4 (m 2 K)/W Performances in accordance with EN14511-3:2011. 15

Cooling capacities - SI system 30XAS standard unit and unit with high energy efficiency (option 119) Condenser entering air temperature, C 20 25 30 35 40 46 LWT Qc EER q Δp Qc EER q Δp Qc EER q Δp Qc EER q Δp Qc EER q Δp Qc EER q Δp C / l/s kpa / l/s kpa / l/s kpa / l/s kpa / l/s kpa / l/s kpa 30XAS standard 242 5 244 3.92 11.8 16 236 3.49 11.4 15 228 3.10 11.0 14 219 2.74 10.6 13 210 2.42 10.1 12 198 2.07 9.5 12 282 297 4.23 13.5 21 287 3.76 13.1 20 277 3.33 12.7 19 267 2.95 12.2 17 256 2.59 11.7 16 241 2.21 11.0 14 342 349 4.35 16.4 31 337 3.86 15.8 29 325 3.42 15.3 27 313 3.02 14.7 25 299 2.65 14.1 23 282 2.24 13.2 20 442 452 4.15 21.1 32 438 3.70 20.4 30 422 3.28 19.7 28 406 2.89 18.9 26 389 2.54 18.2 24 368 2.15 17.2 22 482 490 4.11 23.0 37 474 3.66 22.2 35 456 3.24 21.4 33 438 2.86 20.5 30 418 2.50 19.6 28 393 2.12 18.5 25 242 7 258 3.95 12.4 18 249 3.53 12.0 17 241 3.14 11.6 15 232 2.78 11.2 14 222 2.46 10.7 13 202 2.14 9.8 12 282 315 4.32 14.4 24 305 3.85 13.9 22 294 3.42 13.5 21 283 3.02 12.9 19 272 2.66 12.4 18 257 2.27 11.7 16 342 371 4.45 17.4 35 358 3.96 16.9 32 346 3.51 16.3 30 332 3.10 15.6 28 318 2.72 14.9 26 299 2.31 14.1 23 442 480 4.23 22.4 35 464 3.77 21.7 33 447 3.35 20.9 31 430 2.95 20.1 29 411 2.59 19.2 27 381 2.22 17.8 23 482 521 4.19 24.5 41 503 3.72 23.6 39 485 3.29 22.8 36 465 2.90 21.9 34 445 2.54 20.9 31 419 2.15 19.7 28 242 10 279 4.01 13.5 20 270 3.58 13.0 19 260 3.18 12.6 18 250 2.82 12.1 16 239 2.50 11.6 15 213 2.24 10.3 12 282 344 4.45 15.8 28 333 3.97 15.2 26 321 3.53 14.7 24 309 3.13 14.1 22 296 2.76 13.6 21 280 2.36 12.8 18 342 405 4.60 19.1 41 392 4.10 18.5 38 378 3.64 17.8 35 363 3.21 17.1 33 347 2.82 16.3 30 327 2.39 15.4 27 442 523 4.35 24.5 41 505 3.88 23.7 38 486 3.44 22.8 36 467 3.03 21.9 33 447 2.67 20.9 30 390 2.35 18.2 24 482 569 4.33 26.8 48 549 3.85 25.9 45 529 3.40 24.9 42 507 3.00 23.9 39 485 2.62 22.8 36 422 2.30 19.9 28 30XAS high energy efficiency unit (option 119) 242 5 254 4.12 11.9 16 246 3.69 11.6 16 238 3.29 11.2 15 230 2.92 10.8 14 221 2.59 10.3 12 209 2.22 9.8 12 282 295 4.31 13.8 22 286 3.86 13.4 21 276 3.45 13.0 20 267 3.07 12.5 18 256 2.72 12.0 17 243 2.34 11.4 15 342 357 4.45 16.8 32 346 3.98 16.2 31 334 3.55 15.7 29 322 3.15 15.1 26 309 2.78 14.5 24 292 2.38 13.7 22 442 479 4.32 21.7 34 464 3.88 21.1 32 449 3.47 20.4 30 433 3.08 19.6 28 416 2.73 18.9 26 395 2.34 17.9 24 482 506 4.28 23.7 40 490 3.85 23.0 37 474 3.45 22.2 35 457 3.07 21.4 33 439 2.72 20.6 31 415 2.34 19.5 28 242 7 269 4.19 12.6 18 261 3.75 12.3 17 252 3.35 11.9 16 244 2.98 11.4 15 234 2.64 11.0 14 222 2.28 10.4 13 282 313 4.44 14.7 25 304 3.98 14.3 23 294 3.56 13.8 22 284 3.17 13.3 20 273 2.82 12.8 19 259 2.43 12.2 17 342 381 4.61 17.9 36 369 4.12 17.3 34 356 3.68 16.7 32 343 3.27 16.1 30 329 2.89 15.5 27 311 2.47 14.6 24 442 510 4.45 23.1 37 494 3.99 22.4 35 477 3.57 21.7 33 460 3.18 20.9 31 441 2.81 20.0 29 419 2.41 19.0 26 482 537 4.37 25.2 44 520 3.92 24.4 41 502 3.50 23.6 39 484 3.12 22.8 36 465 2.76 21.9 34 441 2.37 20.7 31 242 10 292 4.28 13.7 21 283 3.84 13.3 20 274 3.43 12.9 19 264 3.06 12.4 17 254 2.71 11.9 16 241 2.34 11.3 14 282 343 4.63 16.2 29 333 4.16 15.7 27 322 3.72 15.1 26 310 3.32 14.6 24 298 2.95 14.0 22 283 2.54 13.3 20 342 419 4.84 19.7 43 405 4.34 19.1 41 392 3.87 18.4 38 377 3.44 17.8 35 362 3.05 17.0 32 342 2.60 16.1 29 442 558 4.62 25.4 43 540 4.15 24.6 41 522 3.71 23.7 38 502 3.30 22.8 36 482 2.92 21.9 33 457 2.51 20.8 30 482 588 4.56 27.7 51 569 4.09 26.8 48 549 3.65 25.8 45 528 3.24 24.8 42 506 2.86 23.8 39 479 2.44 22.5 35 Legend Application data LWT Leaving water temperature, C Qc EER q Δp Cooling capacity, Energy efficiency ratio, / Evaporator water flow rate, l/s Evaporator pressure drop, kpa Standard units, refrigerant: R-410A Evaporator entering/leaving water temperature difference: 5 K Evaporator fluid: chilled water Fouling factor: 0.18 x 10-4 (m 2 K)/W Gross performances, not in accordance with EN14511-3:2011. These performances do not take into account the correction for the proportional heating capacity and power input generated by the water pump to overcome the internal pressure drop in the heat exchanger. 16

Cooling capacities - SI system 30XAS standard unit and unit with high energy efficiency (option 119) for Middle East conditions Condenser entering air temperature, C 35.0 40.6 46.1 47.8 51.7 54.4 LWT Qc EER q Δp Qc EER q Δp Qc EER q Δp Qc EER q Δp Qc EER q Δp Qc EER q Δp C / l/s kpa / l/s kpa / l/s kpa / l/s kpa / l/s kpa / l/s kpa 30XAS standard 242 5.6 234 2.94 9.9 12 223 2.57 9.4 12 213 2.23 9.0 12 209 2.14 8.8 12 201 1.93 8.5 12 160 1.77 6.7 12 282 272 3.10 11.5 15 260 2.71 11.0 14 247 2.36 10.5 13 243 2.26 10.3 12 234 2.04 9.9 12 209 1.90 8.8 12 342 328 3.18 13.9 22 313 2.77 13.2 20 297 2.40 12.6 18 292 2.29 12.3 18 280 2.05 11.8 16 223 1.93 9.4 12 442 440 3.11 18.0 24 421 2.71 17.2 22 401 2.35 16.4 20 395 2.25 16.1 19 364 2.04 14.9 17 271 1.88 11.1 12 482 465 3.09 19.7 28 445 2.70 18.8 26 423 2.34 17.9 23 416 2.24 17.6 23 399 2.01 16.9 21 297 1.88 12.6 12 242 6.7 241 2.97 10.2 12 231 2.60 9.8 12 220 2.26 9.3 12 216 2.17 9.1 12 200 1.97 8.4 12 166 1.82 7.0 12 282 281 3.16 11.9 16 269 2.76 11.4 15 256 2.41 10.8 13 252 2.31 10.7 13 242 2.08 10.2 12 207 1.95 8.8 12 342 340 3.25 14.4 24 325 2.83 13.7 22 308 2.45 13.0 19 303 2.34 12.8 19 281 2.11 11.9 16 194 1.94 8.2 12 442 455 3.16 18.6 25 435 2.76 17.8 23 414 2.39 16.9 21 408 2.29 16.7 21 368 2.08 15.1 17 284 1.93 11.6 12 482 480 3.11 20.3 29 459 2.72 19.4 27 437 2.36 18.5 25 430 2.26 18.2 24 406 2.05 17.2 22 311 1.93 13.1 13 242 7.8 249 3.00 10.5 13 238 2.63 10.1 12 227 2.29 9.6 12 224 2.19 9.5 12 199 2.02 8.4 12 164 1.86 6.9 12 282 291 3.21 12.3 17 278 2.81 11.8 16 265 2.45 11.2 14 261 2.35 11.0 14 251 2.12 10.6 13 215 2.00 9.1 12 342 352 3.32 14.9 25 336 2.89 14.2 23 319 2.50 13.5 21 314 2.39 13.3 20 281 2.17 11.9 16 203 2.01 8.6 12 442 471 3.21 19.3 27 450 2.80 18.4 24 428 2.43 17.5 22 422 2.32 17.2 22 372 2.13 15.2 17 296 1.99 12.1 12 482 495 3.14 20.9 31 473 2.74 20.0 28 450 2.38 19.1 26 443 2.28 18.7 25 407 2.10 17.2 22 325 1.98 13.7 14 242 8.9 257 3.03 10.9 13 245 2.65 10.4 12 234 2.31 9.9 12 230 2.21 9.7 12 197 2.07 8.3 12 171 1.91 7.2 12 282 300 3.26 12.7 18 288 2.86 12.2 17 274 2.49 11.6 15 269 2.39 11.4 15 259 2.16 11.0 14 213 2.05 9.0 12 342 365 3.38 15.4 27 348 2.95 14.7 24 330 2.55 14.0 22 325 2.43 13.7 21 279 2.22 11.8 16 211 2.07 8.9 12 442 486 3.26 19.9 28 464 2.84 19.0 26 442 2.47 18.1 23 435 2.36 17.8 23 375 2.17 15.4 17 309 2.04 12.6 12 482 512 3.19 21.7 33 488 2.78 20.7 30 464 2.40 19.6 27 456 2.29 19.3 26 413 2.1 17.5 22 339 2.04 14.4 15 242 10.0 264 3.06 11.2 14 253 2.68 10.7 13 241 2.33 10.2 12 237 2.24 10.0 12 204 2.11 8.6 12 142 1.89 6.0 12 282 311 3.32 13.2 19 297 2.91 12.6 18 283 2.54 12.0 16 279 2.43 11.8 16 259 2.22 11.0 14 211 2.11 8.9 12 342 378 3.45 16.0 29 360 3.01 15.3 26 342 2.60 14.5 24 336 2.48 14.2 23 289 2.27 12.3 17 220 2.13 9.3 12 442 503 3.30 20.6 30 480 2.88 19.7 27 457 2.50 18.7 25 449 2.39 18.4 24 337 2.28 13.8 14 302 2.08 12.4 12 482 529 3.24 22.4 34 504 2.82 21.4 32 479 2.44 20.3 29 471 2.33 19.9 28 369 2.3 15.6 18 353 2.08 14.9 16 30XAS high energy efficiency unit (option 119) 242 5.6 230 2.82 9.7 12 220 2.46 9.29 12 209 2.13 8.8 12 205 2.04 8.7 12 171 1.85 7.2 12 113 1.56 4.8 12 282 270 3.00 11.4 15 258 2.62 10.9 14 245 2.28 10.4 12 241 2.18 10.2 12 222 1.98 9.4 12 178 1.83 7.5 12 342 326 3.08 13.8 22 311 2.68 13.1 20 294 2.31 12.4 18 289 2.21 12.2 17 239 2.02 10.1 12 184 1.81 7.8 12 442 437 3.00 17.8 23 417 2.62 17.1 22 397 2.26 16.2 20 391 2.16 16.0 19 281 1.98 11.5 12 249 1.77 10.2 12 482 461 2.97 19.5 27 440 2.59 18.6 25 418 2.25 17.7 23 411 2.15 17.4 22 368 1.97 15.6 18 294 1.81 12.4 12 242 6.7 238 2.85 10.1 12 227 2.49 9.6 12 216 2.16 9.1 12 212 2.07 9.0 12 169 1.89 7.2 12 119 1.61 5.0 12 282 279 3.05 11.8 16 267 2.67 11.3 15 254 2.32 10.7 13 250 2.23 10.6 13 222 2.03 9.4 12 151 1.80 6.4 12 342 337 3.14 14.3 23 322 2.74 13.6 21 305 2.36 12.9 19 300 2.25 12.7 18 237 2.07 10.0 12 178 1.82 7.5 12 442 451 3.05 18.5 25 431 2.65 17.6 23 410 2.30 16.8 21 404 2.20 16.5 20 294 2.04 12.0 12 261 1.83 10.7 12 482 475 2.99 20.1 29 454 2.61 19.2 27 431 2.26 18.2 24 424 2.16 17.9 23 321 2.03 13.6 14 307 1.86 13.0 13 242 7.8 245 2.87 10.4 12 234 2.51 9.9 12 223 2.18 9.4 12 212 2.12 9.0 12 176 1.94 7.5 12 125 1.67 5.3 12 282 289 3.11 12.2 17 276 2.72 11.7 16 263 2.36 11.1 14 258 2.27 10.9 14 220 2.08 9.3 12 159 1.86 6.7 12 342 350 3.20 14.8 25 333 2.79 14.1 23 316 2.41 13.4 20 311 2.30 13.1 20 210 2.12 8.9 12 186 1.89 7.9 12 442 467 3.09 19.1 26 446 2.69 18.2 24 424 2.33 17.3 22 409 2.24 16.7 20 306 2.09 12.5 12 254 1.86 10.4 12 482 491 3.03 20.8 30 468 2.63 19.8 28 445 2.28 18.8 25 437 2.18 18.5 25 335 2.08 14.2 15 298 1.90 12.6 12 242 8.9 253 2.90 10.7 13 241 2.53 10.2 12 229 2.20 9.7 12 219 2.15 9.3 12 174 1.99 7.4 12 131 1.73 5.5 12 282 298 3.16 12.6 18 285 2.76 12.1 16 271 2.40 11.5 15 267 2.30 11.3 14 229 2.13 9.7 12 166 1.93 7.0 12 342 362 3.27 15.3 26 345 2.84 14.6 24 327 2.45 13.8 22 321 2.34 13.6 21 219 2.18 9.3 12 178 1.89 7.6 12 442 482 3.14 19.7 28 460 2.73 18.8 25 437 2.37 17.9 23 413 2.29 16.9 21 319 2.15 13.1 13 265 1.92 10.9 12 482 507 3.08 21.5 32 484 2.67 20.5 29 459 2.30 19.4 27 438 2.23 18.5 25 350 2.13 14.8 16 311 1.95 13.2 13 242 10.0 260 2.92 11.0 14 249 2.56 10.5 12 236 2.22 10.0 12 218 2.21 9.2 12 181 2.03 7.6 12 137 1.79 5.8 12 282 308 3.21 13.1 19 295 2.81 12.5 18 280 2.45 11.9 16 276 2.34 11.7 15 227 2.19 9.6 12 174 2.00 7.4 12 342 375 3.33 15.9 28 357 2.89 15.1 26 339 2.50 14.3 23 322 2.41 13.6 21 228 2.25 9.6 12 186 1.96 7.9 12 442 498 3.19 20.4 29 475 2.78 19.5 27 452 2.40 18.5 24 418 2.34 17.1 21 332 2.20 13.6 14 256 1.94 10.5 12 482 524 3.13 22.2 34 500 2.72 21.2 31 474 2.34 20.1 28 438 2.29 18.6 24 364 2.18 15.4 17 301 1.99 12.8 12 Legend LWT Leaving water temperature, C Qc Cooling capacity, EER Energy efficiency ratio, / q Evaporator water flow rate, l/s Δp Evaporator pressure drop, kpa Application data Standard units, refrigerant: R-134a Evaporator entering/leaving water temperature difference: 5.6 K Evaporator fluid: chilled water Fouling factor: 0.18 x 10-4 (m 2 K)/W Performances in accordance with the conditions of AHRI-550/590. 17