FALLING FILM CHILLERS

Similar documents
REFRIGERATION PRODUCTS

REFRIGERATION PRODUCTS

INSTANT CHILLER. Chester-Jensen Co., Inc. Unit Construction and Short Gas Flow

4201 Lien Rd Madison, WI Owner s Manual Therma-Stor III Heat Recovery System. Installation, Operation & Service Instructions

MAC N-407 Air-Cooled Chiller

MACH N-407 Heat Pump Air-Cooled Chiller

Owner s Manual Therma-Stor II Heat Recovery System

Glass Doors, Hinged Bottom Mounts

MAC-036HE-02-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

MAC-048HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

Compressors, Chillers & Condensers

MAC-060HE-01-L High Efficiency Air-Cooled Chiller Air-Cooled Chillers for Global Residential and Light Commercial Micro Climates Rev 1.

OACS Outdoor Air-Cooled Central Chillers

PLATE HEAT EXCHANGERS BETTER BY DESIGN

PROJECT MANUAL GUIDE SPECIFICATIONS FOR: PFANNENBERG SERIES CC COMPACT PACKAGED CHILLERS PART 1 GENERAL

JCseries EVAPORATIVE CONDENSER. engineering data

RDT Refrigeration Book

FOGEL Caribbean Corporation

Part IV: Flow Side Components Flow Diagram

High Capacity Instantaneous Steam Fired Water Heater

Liebert CSU3000 Chiller

Reach In Refrigerators Bottom Mount

Air-Cooling Evaporators

Precise Temperature Control; Compact Footprint

NQ Series Portable Chillers

Process Water Heater For Industrial Applications All Voltages, Single or Three Phase Up To 88 KW

TITAN SERIES Complete Central Chiller & Pump Tank Package 20 to 70 Tons 20 F to 70 F

CL64T INDUSTRIAL TOTE WASHER

Installation &Operating

Call us today! (800)

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

ORTEC HIGH CAPACITY REFRIGERATED AIR/GAS DRYERS

STACT. Model Designations. Model Number: STACT8S6. ST = Portable Scroll Chiller. AC = Air Cooled WC = Water Cooled. T = With Process Tank

HEAT EXCHANGERS Maximize Thermal Efficiency with LaZerWeld Plate Heat Exchangers. For Industrial Refrigeration

ORTEC INDUSTRIAL FLUID CHILLERS FC SERIES ( TONS) Compressed Air, Gas & Fluid Technologies. i e n d. l y. t a. R e. f r. i g e.

QUAD-PLATE CHILLER MODEL QPC

THE PRODUCTS YOU NEED. THE QUALITY YOU WANT. THE INNOVATION YOU DESERVE.

Coil-In-Tank Design: Refrigeration System: Cabinet Construction:

MHNCCX DX with Hot Water Heat Ceiling Concealed 4-Pipe Heat / Cool Fan Coil 12,000-36,000 BTUH

2015 UPC Chapter 8 Indirect Wastes RV

30GXN,R AIR-COOLED LIQUID CHILLERS WITH COMFORTLINK CONTROLS 50/60 Hz

Closing the Loop What s best for your system?

LQ AQ SQ. Air-cooled and water-cooled portable chillers

Q SERIES MEDIUM TEMPERATURE REFRIGERATORS

Call us today! (800)

Call us today! (800)

SECTION 5 COMMERCIAL REFRIGERATION UNIT 22 CONDENSERS UNIT OBJECTIVES UNIT OBJECTIVES 3/22/2012

Reciprocating Simplex and Duplex Tank Mount Compressor Systems Rev. 08/23/12

LQ AQ SQ. Air-cooled and water-cooled portable chillers

START-UP TRAINING AND INSTRUCTIONS HURRICHILL BLAST CHILLERS

Cleveland Range Inc. COMBINATION COOK TANK, CHILLER & SOUS VIDE PRODUCTION UNIT. Cleveland General Specifications. Cleveland Standard Features

I.O.M. #116 7/10 INSTRUCTION MANUAL INSTALLATION OPERATION MAINTENANCE. Covers Models from 25 to 100 tons.

Evaporators. Direct Expansion Flooded Recirculated Over Feed

TYPICAL CPA SPECIFICATIONS

BLU Series Prep Tables. BLU Series Prep Tables. Models ITEM #

BRINE CIRCULATED ICE THERMAL STORAGE SYSTEM DESIGN - CASE ILLUSTRATION - Partial Ice Storage for Air Conditioning Application

KAPTIV-MD KAPTIV-CS KAPTIV-CS-HP NUFORS-CR MAGY-UL MAGY COMPRESSED AIR CONDENSATE MANAGEMENT AND ENERGY SAVING PRODUCTS LEVEL SENSED DRAINS

PACKAGED AIR COOLED Product Data Catalog

Heat Pump Water Heater

Forced Draft, Axial Fan Models Available in Capacities from 124 to 1,408 Ammonia Tons!

CL64e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

CLPS66e DISHWASHER DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE

TURBO Refrigerating HTD and HF Chillers

SB Series Brazed Plate Heat Exchanger Installation Manual


VariCool VAV Engineering Guide

TANKLESS PRODUCT GUIDE CANADA TANKLESS PRODUCT GUIDE. A. O. Smith

H O B A R T F T F L I G H T - T Y P E W A R E W A S H E R. Energy efficient. Water efficient. Cleaning efficient. So you re efficient.

MAC-120HE-03 Air-Cooled Chiller

Refrigeration Plant Information. We Speak Hockey 365

BLAST CHILLER / SHOCK FREEZER MODEL AP3BCF30-1

.2 Section Waste Management and Disposal.

Technical Development Program

A+ Series. Refrigeration Air Coolers. The Heat Transfer Experts

Water-Cooled Dual Compressor Screw Chiller

CL44eR DISHWASHER STANDARD FEATURES MODEL OPTIONS AT EXTRA COST ACCESSORIES DIRECTION OF OPERATION VOLTAGE. Item # Quantity C.S.I.

APV ParaFlow Plate Heat Exchangers

Air-Handling System Cooling Options

EN aquatech.piovan.com

Plate Coil Heat Exchangers

100 TON AIR-COOLED SCROLL PACKAGED. Call us today! (800) SPECIFICATIONS GENERAL DIMENSIONS ELECTRICAL DATA ADDITIONAL INFORMATION

Compressed Air System Products That Save Energy & Improve Operations. Dry, Clean Air for Sensitive Equipment. Refrigerated Air Dryers

SCHMIDT- BRETTEN GASKETED PLATE HEAT EXCHANGERS

VSA SEWAGE PUMP. Capacities to 1600 gpm, Heads to 120, Horsepower range 3/4 thru 40, 3 thru 6 discharge, 1750 and 1150 operation.

RACK-MOUNT Air Conditioners

SECTION AIR COMPRESSORS AND ACCESSORIES

Thomas J Kelly. Fundamentals of Refrigeration. Sr. Engineering Instructor Carrier Corporation. August 20, Page number: 1.

Data Aire LCS TM (Large Ceiling System) R-410A. 6, 8, 10, and 13 ton. ISO 9001 Certified

OTC, OTM and OTI Series Options

Mastering the elements

1025, BOUL. MARCEL-LAURIN INSTRUCTION MANUAL FOR WATER COOLED ENVIROCHILL CHILLER. Prepared par Claude Gadoury, P. Eng MTL TECHNOLOGIES INC.

The Serenity Series: Serenity-X3

Industrial Unit Coolers

Clean-Out-of-Place (COP) Parts Washer

C13-Series Engineering Guide

ParaWeld Plate Heat Exchangers

precision controlled industrial process chillers cooling capacity: ,255,668 BTU /hr ( tons) improved productivity & reduced costs

REFRIGERANT RECOVERY DEVICES AND ACCESSORIES

Air-Handling System Cooling Options

GP SERIES Packaged Chillers

Transcription:

MUELLER FALLING FILM CHILLERS MUELLER FALLING FILM CHILLERS ARE DESIGNED TO COOL ANY FLUID TO WITHIN 2 F OF ITS FREEZE POINT. The primary application for Paul Mueller Company s Other applications include cooling fluids that have an falling film chiller is to cool food-grade liquids that will initial temperature of more than 80 F. This task cannot become an ingredient in a food product, or will come be accomplished in most conventional chillers. into contact with a food product. REFRIGERATION PRODUCTS

The Chilling Solution To qualify as a food-grade chiller, the chiller must meet USDA and FDA requirements. The following are a few important issues to consider: An acceptable material for construction must be chosen. All product contact surfaces shall be visible for inspection. All product contact surfaces shall be smooth and free of pits, crevices, and scale. The product zone shall be free of recesses, open seams, and gaps. All internal corners or angles in the product zone shall have a smooth and continuous radius of 1 4" or greater. Equipment shall be capable of draining all of the fluid it holds. Gaskets and O-rings must be made of approved food-grade material. The falling film chiller was designed to meet all of these requirements and provide you with the chilling solution to all your chilling requirements. 1 1-800-MUELLER www.paulmueller.com

Chiller Components Cabinet Cabinets are available in designs to meet your specific chilling requirements. Standard units are built to accommodate the following: (8) 3 x 5 plates or (8, 16, 24, and 32) 4 x 8 plates. Construction Features Standard units are constructed of Type 304 stainless steel with a 2B finish. All welds are blasted with glass beads. Optional materials are available upon request, including 316L and AL6XN, as well as others. Optional finishes include No. 4 food-grade finish and electropolish for ultra-high purity or corrosive applications, as well as others. Evaporator The evaporator allows water to be chilled as low as 34 F and other solutions to within one or two degrees of their freeze points with no freeze-up problems or chiller damage. Multi-size evaporators are available to meet specific load requirements (3 x 5 and 4 x 8). Evaporator plates are circuited to maintain proper oil return and ensure maximum refrigeration efficiency. The system is suitable for use with R-22, R-404A, R-134A, and ammonia refrigerants as well as most new non-cfc refrigerant products in flooded, recirculated, or directexpansion systems. Built to ASHRAE 15 standards, the system is rated at 300 psi at 400 F. Optional ASME code-stamped evaporators are available. Fill Connection Chillers are equipped with a threaded fill connection which allows for the use of electronic level controls. The fill connection is located on the water pan inlet. Optional Refrigeration Manifolding Optional manifolding is available for all types of refrigerants. When direct expansion refrigeration systems are used, manifolding includes the mounting of required expansion valves. Copper or stainless steel would be the ideal material to choose. Overflow Connections All chillers are equipped with a female, threaded overflow connection, which allows for simple piping of excess fluid. Tank Reservoir Standard tank sizes are available from 190 to 1,400 gallons. The holding tank is insulated with a minimum of 2-inch insulation for elimination of heat loss and condensation buildup. A sloped bottom allows for complete drainage of the holding tank. Adjustable legs enable the chiller to sit level on uneven surfaces for proper operation of the distribution pan and allow an even laminar flow pattern over the evaporator plates for maximum cooling efficiency. Water Distribution Pan The distribution pan has holes over each vertical evaporator plate to allow a thin, uniform solution to flow over both sides of each plate. The hole size and spacing are determined by the flow rate requirements for each chilling application. Pans are available in extra low, low, and high flow. Minimum flow is 1.2 gpm per linear foot of plate with a maximum flow rate of 6.2 gpm per linear foot of plate. Mueller Refrigeration Products 2

Features and Benefits Standard Option Concept The falling film chiller was designed around the standard option concept to improve quotation lead time, delivery time, and lower cost. This concept has allowed us to pre-design the entire product line once, which eliminates the unnecessary cost of re-engineering a custom product for each order. By taking the time to evaluate the needs of all of our different customers, we were able to design all of the needed options. This also makes it unnecessary for our customers to pay for something on their chiller they do not need. These two advantages provide you with the lowest cost and the shortest lead time in the industry. Cabinet Sizes We currently build two chiller sizes, 3 x 5 and 4 x 8. The 3 x 5 chiller is available in an 8-plate cabinet. The 4 x 8 chiller is available in an 8-, 16-, 24-, and 32-plate cabinet. Each of these chillers has a tank that was properly sized to satisfy the requirements of the chiller. We also offer a tankless chiller cabinet in the following sizes: 8-plate 3 x 5, 8-plate 4 x 8, 16-plate 4 x 8, and 24-plate 4 x 8. Cabinet Top Options Each cabinet is available with a welded in place top or a top fitted with a hinged door over each distribution pan. The above options allow for access (or not) to the top of the chiller, depending upon your needs. Cabinet Expandability Adding additional plates (up to cabinet capacity) is nearly effortless due to the advanced cabinet design of all of our chillers. So, be sure to select a cabinet that allows for future expansion when you are ready to buy your next chiller. When expansion time comes, you will only have the cost of additional plates and distribution pans, not a second chiller which requires an expensive installation. Evaporator Features and Options We offer 3 x 5 and 4 x 8 plate sizes. Each plate size is available for DX, recirculated, and flooded refrigerant controls for conventional refrigerants. Due to the plate design, no special refrigerant controls are necessary, nor are you forced to select flooded controls when DX would be less expensive and a better fit for your application. All plates are built to ASHRAE 15 standards rated at 300 psi at 400 F. Optional ASME plates at the same rating are available. Evaporator Internal Plate Capacity Mueller s patented Temp-Plate is the most efficient falling film chiller evaporator available today. Each evaporator is designed to use the smallest refrigerant charge possible and is circuited to ensure that the entire evaporator operates at the correct temperature. The internal volume is.15 cubic feet for the 3 x 5 plate and.42 cubic feet for the 4 x 8 plate. These capacities are 8 to 10 times less than others. Tank Connection Options Each chiller is laid out with multiple locations for tank connections. This option allows you to pick the location and any standard size connection for your chiller. You can select the connection size and location from our list of standard connections located on the submittal drawing for each cabinet. Refrigerant Controls We provide DX and flooded refrigerant controls for all refrigerants. For details on the individual components, review the Falling Film Chiller Operations and Installation Manual. 3 1-800-MUELLER www.paulmueller.com

Water Level Control Option All Mueller falling film chillers are equipped with a 1 4" connection to allow for the installation of an optional water level control. This control will allow you to set the upper and lower level anywhere you choose. There are three optional control panels which allow you to set the level control. The three components needed to operate the level control are the pressure transducer, a 1" water solenoid valve, and one of the optional control panels described in the Control Panel Options section. Control Panel Options We offer three standard control panels. The following is a brief description of each panel. Model 100 Control Panel The Mueller Model 100 chiller control is designed to control chiller water temperature. It requires 230/60/1 electrical input. Outputs to control temperature are 24-volt to operate a refrigeration unit, chiller circulation pump, process circulation pump, and optional water level control and fill solenoid valve. Model 200 Control Panel The Mueller Model 200 chiller control is designed to control chilled water temperature. The chiller control will accommodate 208/60/3, 230/60/3, or 460/60/3 electrical input. Outputs to control temperature are 24-volt and can operate up to four stages of refrigeration. It will also control the operation of a chiller circulation pump (up to 5 hp), a process circulation pump (up to 5 hp), and optional water level control and fill solenoid valve. Level Control Panel This board is mounted in the 6" x 6" level control box and can be used to set up the reservoir level to control the water fill valve. Refrigeration Units We offer a complete line of condensing units that have been designed to match the performance requirements of the falling film chiller. These units are available in outdoor air-cooled, water-cooled, and remote aircooled (with outdoor) condensers. Each type of unit is available in horsepower sizes from 5 to 120 hp. Some sizes may not be available in all types. Specially Designed High Sides Custom high sides of all sizes and configurations are available upon request. Quotation Lead Time For quotations on chillers with standard options, the normal lead time is 24 hours or less from the time we receive your request. Requests for quotes that include no standard options may take longer. Order Lead Time The normal shipment lead time after the receipt of an order is four weeks. Some orders with special requirements may take up to two weeks longer. Quality, price, and service Mueller provides all three! Mueller Refrigeration Products 4

Options, Accessories, & Other Equipment Refrigerant Controls Refrigerant controls for ammonia and other refrigerant including direct expansion, flooded, and recirculated systems are available. Refrigerant Circuit Manifolds Refrigerant circuit manifolds are available to simplify installation. Manifolds for DX systems include valves and external equalizers already mounted. Flooded and recirculated manifold are available in copper and stainless steel materials. Additional Equipment Surge drums, receivers, hand valves, and other refrigerant accessories are available upon request. Temperature Control Assemblies Temperature control packages are available to control temperature, circulating pumps, and make-up water levels. Pumps Circulating pumps are available in various flow ranges and materials to suit your needs. Condensing Units Condensing units (semi-hermetic and scroll compressors) are available in air-cooled, remote aircooled, or water-cooled models. 5 1-800-MUELLER www.paulmueller.com

3 x 5 Chillers The Mueller 3 x 5 falling film chiller reduces chilling time, increases production, and brings a faster return on your investment. The Mueller 3 x 5 falling film chiller is designed with a fully welded cabinet that includes a hinged and gasketed door for access. Built for lower-capacity applications, the unit is equipped with a 190- or 400-gallon self-contained storage tank. Distribution pans are available with extra-low, low, and high flow rates, based on chilled water usage. Extralow flow rates range from 4 to 10 gpm, low flow rates range from 8 to 15 gpm, and high flow rates range from 16 to 30 gpm (per evaporator). 3 X 5 CHILLER SIZING CHART No. of Plates Dimensions Maximum Shipping Tank Capacity Distribution Pan Cabinet Size Minimum Maximum L x W x H (in) Weight (lbs) (gal) Connection Size N 2 8 68 1 2 x 36 1 2 x 77 3 4 1,820 190 2" or 3" O 2 8 68 1 2 x 36 1 2 x 97 3 4 2,020 400 2" or 3" Notes: Refrigerant inlet connection size per plate is 1 1 8" tube and the outlet size is 1 1 2" tube. Maximum weight is based on the maximum number of plates that a chiller will hold being in the chiller. Low flow/extra-low flow distribution pan connection is 2". High flow distribution pan connection is 3". Mueller Refrigeration Products 6

4 x 8 Chillers Fully enclosed design eliminates product contamination. The Mueller 4 x 8 enclosed-type falling film chiller is fully enclosed to ensure your product is free from airborne particles. The unit is easily accessible through gasketed doors and is designed for large-capacity chilling applications. Distribution pans are available in extra-low, low, and high flow rates, based on chilled water usage. Extra-low flow rates range from 6 to 16 gpm, low flow rates range from 13 to 24 gpm, and high flow rates range from 25 to 48 gpm (per evaporator). 4 X 8 CHILLER SIZING CHART No. of Plates Dimensions Maximum Shipping Tank Capacity Distribution Pan Cabinet Size Minimum Maximum L x W x H (in) Weight (lbs) (gal) Connection Size J 2 8 104 1 2 x 39 1 8 x 90 3 4 2,735 361 4" or 6" K 2 16 104 1 2 x 72 3 8 x 90 3 4 5,220 706 (2) 4" or 6" L 2 24 104 1 2 x 105 7 8 x 90 3 4 7,705 1,052 (3) 4" or 6" M 2 32 104 1 2 x 139 x 90 3 4 10,190 1,397 (4) 4" or 6" Notes: Refrigerant inlet connection size per plate is 1 1 /8" tube and the outlet size is 2" pipe. Maximum weight is based on the maximum number of plates that a chiller will hold being in the chiller. Low flow and extra-low flow distribution pans have a 4" connection and high flow pans have a 6" connection. 7 1-800-MUELLER www.paulmueller.com

4 x 8 Chillers Back View (left) Gasketed door with latches make the chiller easily accessible for inspection and servicing. Outlet connections are available in various sizes and piping configurations. Top View Optional top doors are available for accessibility to the distribution pan for needed cleaning. Inlet Connection Overflow Connection Water Level Control Inlet connection is shown here with optional make-up water valve. Each chiller has an overflow connection to guard against over filling the reservoir. Optional water level sensor is available if needed. Mueller Refrigeration Products 8

Tankless Chillers Versatility to match your specific storage needs. Mueller s tankless chiller is designed for applications where it is necessary to place the chiller over the top of an existing tank. Distribution pans are available in extra-low, low, and high flow. Units are available in both 3 x 5 and 4 x 8 evaporators from 8- to 24-plate cabinets. TANKLESS CHILLER SIZING CHART Cabinet L x W x H Weight with Refrigeration Connection Size Water Pan Size (in) Plates (lbs) Inlet* Outlet* Connection Size 8-3 x 5 70 x 43 x 48 990 1 1 8" Tube 1 1 2" Tube 2" or 3" MPT 8-4 x 8 108 x 43 x 62 1,550 1 1 8" Tube 2" Pipe 4" or 6" MPT 16-4 x 8 108 x 67 x 62 2,980 1 1 8" Tube 2" Pipe (2) 4" or 6" MPT 24-4 x 8 108 x 104 x 62 4,220 1 1 8" Tube 2" Pipe (3) 4" or 6" MPT Note: *Inlet and outlet connection sizes are per plate connection sizes. 9 1-800-MUELLER www.paulmueller.com

Falling Film Chillers Falling Film Chiller Model No. Breakdown Plate Sizes N = 3 x 5 L = 4 x 8 Cabinet Models I = Tankless J = 361 4 x 8 2-8 K = 652 4 x 8 9-16 L = 943 4 x 8 17-24 M = 1234 4 x 8 25-32 N = 190 3 x 5 2-8 O = 400 3 x 5 2-8 Sanitary/ Non-Sanitary 1 = Sealed Edge 2 = Non-Sealed Edge ASME/Non-ASME A = ASME N = Non-ASME No. of Plates 3 x 5 = 2-12 4 x 8 = 2-36 Refrigeration Control Type A = R-22 DX B = R-404A & R-507A DX C = R-134A DX D = R-717 DX E = R-22 Flooded F = R-404A & R-507A Flooded G = R-134A Flooded H = R-717 Flooded I = R-22 Recirc J - R-404A & R-507 Recirc K = R-134A Recirc L = R-717 Recirc M = Glycol N = Other Cabinet/Plate Material 1 = 304 / 304 2 = 304 / 316L 3 = 316L / 316L 4 = 304 / 304EP 5 = 304 / 316L EP 6 = 316L / 316L EP 7 = Other Manifold 1 = Yes 2 = No Pan Type 1 = High Flow 2 = Low Flow 3 = Extra-Low Flow Mueller Refrigeration Products 10

1600 West Phelps Street Springfield, Missouri 65802, U.S.A. Phone: (417) 831-3000 1-800-MUELLER Fax: 1-800-436-2466 www.paulmueller.com Email: refrigeration@paulmueller.com 1998-2005 Paul Mueller Company CR-1225-5