Elite. GJD022 /GJD023 35m External PIR. Multi Beam Lens Data

Similar documents
Movement Detector GJD 300

D-Tect 2 GJD300 Quad PIR Movement Detector

D-TECT Introduction. Connecting the Unit. Quick Installation. Multi Beam Alignment & Masking. Mounting the Unit

D-TECT Dual Tech. GJD360 Triple Technology External Detector

GJD OPAL RFX WIRELESS 35 METRE EXTERNAL PIR INSTALLATION MANUAL

Installation Manual Premier Elite Orbit QD/DT INS483-2

DI601AM Outdoor PIR/AM Detector Installation Sheet

D-TECT 2 IP. GJD230 IP Motion Detector

D-TECT 3 IP. GJD260 IP Motion Detector

Intrusion Outdoor Protection Perimeter

Emerald 3000 MK3 GJD010 Lighting Controller

LUX Hardwired - Installation Notes

Description. Optex Incorporated

INTERNAL DETECTORS. Wired and two-way wireless grade 2 and 3 internal detectors

The most user friendly Security Alarm System L S Section 1 Overview of System Section 2 Planning your Installation

DYGIZONE GJD910 Lighting Controller & Enunciator

PRODUCT GUIDE Electronic Perimeter Detection & High Performance LED Illumination

design line performance line Guardall DesignLine & PerformanceLine detector series 2015 Peace of mind

English. Series. Installation and Use Manual

Advanced DIGITAL Wired PIR Motion Detector

STANDARD FEATURES SPECIFICATIONS

High Mount. Low Mount. High security wired tri-technology external detectors with anti-masking

DS9370-BEL. Installation Instructions TriTech Ceiling Mount PIR/Microwave Intrusion Detector

DUAL ZONE OUTDOOR PIR MS-12TE & MS-12FE

DT900 Series Sensors TECHNOLOGY FOR LARGE COMMERCIAL AND INDUSTRIAL APPLICATIONS. Impressive Performance, Impressive Coverage

Mounting bezel Retaining spring. Detects movement within the detection range, allowing load control in response to changes in room occupancy.

LS800S Intruder Alarm System. Engineering Manual

The Genesis. Wireless PIR System. Se t t i n g n e w s t a n d a r d s f o r P I R d e t e c t i o n. BS8418 Compliant

DS160/161 Request To Exit PIR sensors Installation Instructions

SECURITY LIGHT MODEL NO: CL6PIR OPERATION INSTRUCTIONS PART NO: GC0215

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

l High precision, computer-designed parabolic optical system,. Dual element pyro-electric sensor.

M O T I O N DETECTORS. The Paradox series of motion detectors. combines advanced features and patented. technologies to provide a high level of

Wireless security products

Extended Range DUAL TEC Motion Sensor

ISC-PDL1-W18G-H. Installation Instructions Professional Series Dual Detector

English. Italiano. Português. Françias. Español

Passive Infrared Motion Detector 5420/90P. Installation Instructions

Dual Technology Wall Mounted Occupancy Sensor. Manual & Specification

DS160/DS161 Request To Exit PIR sensors Installation Instructions

Active Infrared Multi Beam Sensors

"Pegaso" wireless alarm system

GS100-ATEX. Hazardous Areas Infra-Red Beam PULSE MODULATED ACTIVE INFRA-RED BEAM FOR HAZARDOUS AREAS ZONE 1 OR ZONE 2 GENERAL

Active Infrared Multi Beam Sensors. R Series

Microwave/PIR Intrusion Detector with POPIT Interface ZX970

Installation and user manual for the FX range of fire panels. 1, 2, 4 and 8 zone panels

Infrared Wall Mount Occupancy Sensor

INSTALLATION INSTRUCTIONS. This model is UL Listed product. The comment with *UL-Number are UL s requirements and information for using this product.

FEC400 Series. Installation Manual

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

FR-A180 FR-A360. Occupancy detector. Use

LPCMPIRM65 & LPCMPIRDSI65

DH400. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer.

DT8016AF4 / DT8016AF5 DUAL TEC Motion Sensor with Anti-Mask Installation Instructions

DHR3. Accessories. NOTE: Set up for this sensor should be performed by an AAADM-certified installer. INSTALLATION INSTRUCTIONS

System 800 Addressable Fire Detection & Alarm System

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

Installation and user manual for the CF5000, MF5000 and FXP5000 range of fire panels

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

Hardwired Alarm Accessories

5800-OD Wireless Outdoor Motion Sensor Installation Instructions

OPERATING AND MAINTENANCE MANUAL. for the G30 CARBON DIOXIDE MONITOR

TX7130. Conventional Reflective Beam Detector Installation and Operation Manual. TANDA UK Technology Copyright 2015, All right reserved.

Open-area Smoke Imaging Detection (OSID)

LC-151 Dual-Tech Motion Sensor (Single PIR & Microwave) with adjustable Pet Immunity INSTALLATION INSTRUCTIONS & USER MANUAL P/N: ver.

HX-80NRAM. High Mount Outdoor Detector

DUAL OPTIC. Installation manual

360º Surface Mount Ceiling PIR Light Controller

PHOTOELECTRIC DUAL BEAM DETECTOR R4222 RECEIVER INDICATORS 1

IMPORTANT. PLEASE NOTE: The infrared beam path MUST be kept clear of obstructions at all times!

Photobeam 5000 ISC-FPB1-W60QS, ISC-FPB1-W120QS, ISC-FPB1-W200QS. en Installation and Operation Guide

5 Litex Elite. Industrial. Up to 170Llm/cW. Mains lighting IK10

2G & 3G GSM Portable PIR Alarm

PSC-BL-I-FM-DC0(-BLE) Bi-level Dimming PIR Sensor

DUAL TECHNOLOGY SENSOR (PIR + Microwave) Outdoor use INSTALLATION MANUAL

For assistance with the product please contact: HELPLINE. For a product brochure please contact:

HA-263K HA-263D. OWNER'S MANUAL Installation And Operation 8-ZONE ALARM CONTROL PANEL FOR HOME AND OFFICE PROTECTIONS OPEN THE CABINET FOR SERVICE

Intelligent addressable fire alarm control panel

REDWALL-V series REDWALL-V INSTALLATION AND MAINTENANCE NOTES. Synthesized Intelligent PIR FEATURES INSTALLATION HINTS PARTS IDENTIFICATION

TO ARM/DISARM ALARM The alarm is activated by pressing BUTTON 1 on the remote control transmitter once. The blinkers will flash once, and the

Wireless Sensors. Security unplugged. Interlogix wireless sensors deliver reliable detection and flexible installation for multiple applications.

HDCVI PIR Camera User s Manual

Installation Instructions

Quick Selection Guide Intrusion Detectors

Welcome. Welcome to the new Optex Event-Driven CCTV catalogue.

IN A BOX. User Manual YOUR HOME SECURITY SYSTEM. curv360.co.uk. Support APP remote arm/disarm, parameter settings and accessories management

Occupancy Sensor LS Descriptions. Product Profile. Technical Specifications

Cimco Series 21. Series 21 - Specifications INDEX. Description. Operational Specification 2

2G & 3G GSM Wireless Beam Alarm

Multi-layered Perimeter Protection Systems Quality detection systems for high security sites

C-Bus PIR Occupancy Sensor. Installation Instructions 5751L

MO144. Operators Guide. Universal Timer Module

Intrusion sensors. We listened to you

Installation, Operating and Maintenance Manual

7XG3130 ReyArc30 Optical Arc Fault Sensor Energy Management

ELECTRONIC SOUNDER STROBE Model : AVD-C407

Model: MLSA360N. Installation & Operating Instructions. 360º Night Eye PIR Light Controller

Photobeam 5000 ISC-FPB1-W60QF, ISC-FPB1-W120QF, ISC-FPB1-W200QF. en Installation and Operation Guide

Premium 8 Zone Wireless Alarm Kit

Model 3300 Technical Support and Installation Manual

Transcription:

Elite GJD022 /GJD023 35m External PIR Multi Beam Lens Data The GJD multifunction lens fitted to the GJD Elite detector produces 9 long range beams and 9 medium to short range curtain beams. Movement across the beams produces the best response and range, whilst movement towards the detector will be less responsive. An independent passive infrared detector that simultaneously or individually controls cameras, VCR s, DVR s and all low voltage switching requirements. When mounting higher than boundary fences rotate the module and mask off any beams, either vertically or horizontally, that fall outside the area being covered. Use portions of the self-adhesive silver mask supplied to the rear, smooth side, of the lens and always replace the correct way up as shown to obtain the exact beam pattern coverage. The Elite offers a high level of adaptability, there are seven different modes of operation giving various permutations of normally open and normally closed arrangements for the two pairs of volt-free relays, plus a selection of timing and functional options for the relay changeover contacts. MULTI-BEAM OPTIMUM 3 METRES 0 DEGREE LONG 30 METRE SECTION 10 TO 20 METRE SECTION 3 0 deg 0 10 20 30 35 Other programmable parameters include the duration of timed changeover, a pulse count feature and a choice of detection ranges from 10 to 35 metres. In addition there are two switched negative outputs. The A output gives a single 400ms trigger every time the detector activates and is generally used in conjunction with the GJD lighting controllers to give 24 hour visual and audible alarm indication. The S output is the only photocell- controlled output giving a fixed 0-second trigger on activation. The flexibility of the four outputs and timers allows the Elite to be used in multiple situations without the need for any further customised equipment. The integral dual axis title sensor allows 180º of pan and 90º tilt. This increases the speed of the outdoor installation and provides incredibly accurate aiming of the detection pattern. The electronics module is acrylic coated for additional component stability. It is encased in a vandal-resistant high impact ABS housing with a UV stabilised translucent front cover ensuring the sensor is impervious to and unaffected by weather conditions. The Elites effective design gives a neat appearance with no visible indication of the orientation of the detector head, and totally hides the wiring. MULTI-BEAM OPTIMUM METRES 9 DEGREE PET IMMUNITY 1.5 METRES 0 5 10-2 DEGREE CURTAIN COVERAGE METRES 15 10 5 45 DEGREE MASK OFF FOR PET ALLEY APPLICATIONS UP TO 35 METRES MASK OFF FOR CURTAIN COVERAGE APPLICATIONS 15 0 5 10 15 20 25 30 35 4 2 0 2 4 1.5 9 deg 0 10 20-2 deg 30 35 0 10 20 30 35 45 deg 0 5 0 5 10 15 0 2 4 8 10 12 14 Beam Pattern set to maximum range. Masking top section of lens will reduce range to 20 metres Beam Pattern set to maximum range. Masking top section of lens will reduce range to metres

Changing The Existing Setting ELITE PROGRAM TABLE All settings can be changed to suit individual requirements. The programmable table indicates the factory settings. Changes to the existing settings can be easily made either before installation (e.g temporarily power the unit with a PP3 battery) or by applying 12 volt to the unit on site. Once changes are made they are stored in the non-volatile memory, When power is applied the red indicator lights for 0.5 of a second. GREEN SELECTIONS 1x Range - Mtrs (Approx) 10 15 20 28 35 2x Pulse Count 1 2 3 4 3x LED Monitor OFF/ TP 4x S Output Lux Level 5x / Mode x / ON/ TP OFF/ NT ON/ NT OFF/ LO 2 5 25 30 0 120 240 24 HR 1 2 3 4 5 7 2 5 10 15 20 25 30 45 0 Red Options 1x 2x 3x 4x 5x x 7x 8x 9x 1. To enter program mode press and hold down the program button - the RED indicator lights for 4 seconds then the GREEN indicator sequences through the six selections. One flash for the range, two for the pulse count. Three- LED monitor. Four- S lux level. Five for contact mode and six to change the timer setting. (see program chart Page 5) 2. When the required selection is reached, release the button. 3. The red led then flashes for the number representing the present option setting. 4. If you want to change the present option setting - hold down the button again within 3 seconds. The red flashes will then sequence through the options available for that selection. Release when the number of red flashes corresponds to your option. 5. The program mode exits after 3 seconds - all amendments are stored in the non-volatile memory. EXAMPLE 1: Altering the range from 20 metres to 35 metres Hold down the program button. The red indicator lights - keep held until the green led flashes once then release - the red led will flash three times - hold again until four red flashes, the five red flashes - then release. EXAMPLE 2: Altering the / output mode from mode to mode 1 Hold down the program button. The red indicator lights - keep held until the sequence of five green flashes then release - the red led will flash six times - hold again until seven red, then one red flash then release. To reset to factory settings Power down the unit and then power back up whilst holding the program button in. Release the program button when the indicator flashes green. Shaded boxes are the factory settings The range of the detector can be set from 10 to 35 metres. See the multi-beam lens data on page 1 for masking off areas to reduce the range further or pet alley requirements. PULSE COUNT The number of beams that have to be crossed before activation. 1 - will give a fast response 2 - gives good immunity & response 3 - gives high immunity to false alarms 4 - slow repose use in areas with poor environments ( e.g excessive foliage) The unit detects the changes in heat and movement in the beam pattern area, therefore trees, shrubs, ponds, boiler flues and animals should be considered when positioning the detector. LED MONITOR OFF/tp: Detection indicator off select this when requiring Tamper outputs with mode 1 and mode 7 ON/tp: Detection indicator on select this option when requiring Tamper outputs with mode 1 and mode 7 (see page ) OFF/nt: The indicator is off; - both & outputs activate on detection ON/nt: The indicator is on - both and outputs activate on detection. OFF/lo: Low power mode supply 5mA - only the A and S output operate - no led indication. S OUTPUT The light level that the S -ve output operates. The factory setting is 5 lux. This is generally considered the average light level at dusk. 24 hr activates the S output irrespective of light level. ALARM 2 / ALARM 1 MODE There are seven different normally open and normally closed modes that the 24 hour volt free contacts can be utilised. See page for these options. TIMER ALARM 2 / ALARM 1 The timer settings available for the and volt free outputs.

VOLT FREE OUTPUTS ALARM 1, ALARM 2 & TAMPER MODE VOLT FREE OUTPUT STATE ACTION ON DETECTION Mode 1 Normally Open will close for the TIMER period after detection TAMPER e.g. MUX and Alarm panel option Normally Closed remain closed on detection. Utilise the connection for tamper loop. The output will also open for 2 seconds if the front cover is removed. Mode 2 Normally Open will close for the TIMER period after detection Normally Open will close for the TIMER period after detection Mode 3 (Factory Settings) (Factory Settings) Normally Open Normally Closed Will close for the TIMER period after detection Will open for the TIMER period after detection Mode 4 Normally Open will close for 0.4 second every time a detection takes place Normally Closed will open for the TIMER period after detection Mode 5 Normally Open will close for 0.4 second and can only re-trigger with detection after 4 seconds of non-activity Normally Closed will open for the TIMER period after detection Mode Normally Open will close for 0.4 second and can only ve re-triggered every 4 seconds with detection Normally Open will close for the TIMER period after detection Mode 7 Normally Closed will open for the TIMER period after detection TAMPER e.g. MUX and alarm panel option Normally Closed remain closed on detection. Utilise the connections for tamper loop. The housing is pressure regulated - the output will also open for 2 seconds if the front cover is removed INSTALLATION During installation the electronics must be protected against water, as trapped moisture can effect or damage the unit. 1.First remove the front polythene cover by pulling forwards, then remove the lens module by pulling it out of the forked bracket. 2. Drill the wall to accept the top fixing and the lower cable entry. The holes should be on 1mm centres. 3. Feed standard 8 core alarm cable into lower cable entry: bare the wires and connect to the removable terminal block. 4. Always ensure when replacing the module that it is the correct way up for the correct alignment of the beam pattern. 5. Replace the front cover with the ventilation hole at the bottom. Ensure the cover engages both sides of the outer casing before pressing firmly to locate it securely. At this stage the unit can be walk tester with the front cover fitted. Use the program table on page 5 to adjust the range as necessary and pan and tilt the lens module over the field of view to obtain the correct coverage area. WALK TEST Alignment of detection beams The range of the detector increase without the front protective cover. Therefore the front cover must be fitted to establish the correct beam pattern alignment and when testing the outputs. When the program button is pressed momentarily the red indicator lights and pulse count 1 is automatically selected. The unit can then be aligned. The red indicator will light on the Elite every time a detection takes place. This test mode will automatically cancel five minutes after last detection. Alternatively, remove the power and then re-apply. If automatic lighting is required to illuminate the area during recording, the Elite PIR connects directly into any of the GJD lighting controllers for simultaneous recording and automatic lighting at dusk. The signals from the detector also provide an audible and visual indication of the detection activity 24 hours a day. As the controllers also have a pulse count option, this must be set to 1 on the controller when using the Elite PIR for event recording. TESTING USING A METER Testing the volt free contacts - as the Elite has an integral 25R series resistor the meter should be set to greater that 100 ohms rather than a continuity test setting.

ELITE APPLICATIONS STANDARD WIRING and outputs active on detection 24 hours a day see page 5 for configurations of normally open or normally closed contacts. Mode-2 to Mode- MUX APPLICATION: When tamper is required select either: Mode-1 Normally Open - /Alarm or Mode-7 Normally Closed - /Alarm select LED OFF/tp or LED ON/tp ALARM PANEL: When tamper is required select either: Mode-1 Normally Open - /Alarm or Mode-7 Normally Closed - /Alarm select LED OFF/tp or LED ON/tp STANDARD Standard wiring - two pairs of 24 hour volt free outputs combined with infra red lighting activated at dusk for 0 seconds after last detection. Mode-2 to Mode-.

Detection Area Coverage Adjustment Fresnel Lens Elite Specifications 10 to 35 metres (adjustable) up to 750 sq metres 90 degree 35 metres x 30 metres max 180 degree pan + 90 degree tilt Area reduction mask (if required) 3 zone-white Light Filter Customised Optics Double silicon shielded dual element eliminates 50,000 lux of white light Outputs Silent solid state magnetically immune No.1 Output Volt free relay signal contact - 24VAC/ DC @50mA with an integral 25R series resistor; selectable normally open/normally closed. Adjustable timer options: 2 to 0 seconds No.2 Output Volt free relay signal contact- 24VAC/ DC @ 50mA. Selectable normally open/normally closed with an integral 25R series resistor. Adjustable timer options: 2 to 0 seconds No.3 Output A Open collector negative switching - 25mA max. Alarm period 400ms No.4 Output S Open collector negative - 25mA max. Alarm period: detection + 0 seconds Adjustable: Dusk (2 lux) to 24 hour Power Input Current Pulse Count 9 to 15 VDC 10mA (12V nominal) 1 (2,3 & 4 previous Detection < seconds) Tamper Selectable - Mode 1 or 7 plus output opens for 2 seconds when cover removed and/or A & S outputs pulse for 0 seconds Temp.Compensation Control Walk Test Operating Temp. Housing Protection Rating Dimension Weight Mounting Height Cable <200 metres Cable <500 metres Digital sensitivity adjustment Digital ASIC/microprocessor - non volatile memory Output test mode with LED indication -20 to +55 centigrade Conformally coated electronics for increased stability High Impact ABS IP55 104 x 104 x 94mm 145 grams Variable - optimum height 3 metres Utilising all four outputs - 8 core 7/0.2mm Utilising all four outputs - 8 core 1/0.2mm Technical: 0170 33990 Sales: 0170 33998 Fax: 0170 33991 Email: info@gjd.co.uk