Power Transfer Devices. Access Control Accessories. How To Order. How to Order

Similar documents
POWER TRANSFERS ACCESSORIES EAC. Manufacturer Product Product No. Product Description Item No.

Accessories. Desk Top Controls

Accessories DESK TOP CONTROLS MODELS SPECIFICATIONS MODELS SPECIFICATIONS UNDER DESK TOP MOUNTING MINI DESK TOP CONSOLE

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

Accessories. Desk Controls. Break Glass Emergency Door Release SECURITY DOOR CONTROLS

SECURITRON MODEL EXD EXIT DELAY SYSTEMS INSTALLATION AND OPERATING INSTRUCTIONS 1. DESCRIPTION

RDM LOCK G Series Electromagnetic Lock. Listings. Standard Features. Ordering Information:

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

GATE & Fence. Solar Power Supplies. Gate Locks. Gate Lock Bracket Kits. Specialty Brackets. Power Supplies. And More...

300 SERIES MINI MAGNETIC LOCK 1000 SERIES INDUSTRIAL MAGNETIC LOCK 1100 SERIES ARCHITECTURAL MAGNETIC LOCK 1100 SERIES MORTISE MAGLOCK & DOOR PULL

SECURITRON MODEL DPA-12 AND DPA-24 DOOR PROP ALARM TIMERS INSTALLATION AND OPERATING INSTRUCTIONS

Multi-Mode Annunciators

System components portfolio overview. Power supplies, electromagnetic locks, electric strikes and system accessories

STANDARD FEATURES SPECIFICATIONS

Section 1: General Description. Section 2: Features. Section 3: Operation. CM-RQE70 PIR REQUEST TO EXIT DETECTOR Installation Instructions.

SP-1000X. Panic Device Power Controller Installation Guide. Rev

Egress Devices for Code Compliant Access-Controlled Egress Doors

POWER SOURCES MODEL NO. DESCRIPTION PRICE

MODEL KP-200 VANDAL RESISTANT & WEATHERPROOF FLUSH MOUNT DIGITAL KEYPAD DESIGNED FOR ACCESS CONTROL APPLICATIONS

OPTICAL TURNSTILE SYSTEM

CHECK NEW PRODUCTS SECTION FOR NEW INNOVATIVE SOLUTIONS

CM-RQE70 PIR REQUEST TO EXIT DETECTOR

Delayed Egress System DORMA EMDE

DS160/161 Request To Exit PIR sensors Installation Instructions

DS160/DS161 Request To Exit PIR sensors Installation Instructions

ALARMED EXIT HARDWARE

ACSI MODEL 1410 POWER SUPPLY INSTALLATION INSTRUCTIONS

Power Supplies. Overview

Upgrade Your Solution: Mechanical to Electrical

705 Emmett Street Bristol, CT DynaLock MODEL 3101C-TJ101 DELAY EGRESS SYSTEM WIRING INSTRUCTIONS

Security Professional Mobile Showroom. Product Training

Installation Instructions. PS902 Power Supply. These instructions cover the following parts: PS902 Power Supply Specifi cations:

MODEL B2 INSTALLATION MANUAL

Exit Switches SECURITY DOOR CONTROLS. 400 Series 410 & 420 Series. Finishes. Finishes. Options. Options. Specifications.

CM-RQE70A PIR REQUEST TO EXIT DETECTOR

4700 SERIES PLC INTERLOCK CONTROLLER

/ How To Order

Section 1 General Description

ACSI AO ELECTRIC LATCH RETRACTION CONTROLLER INSTALLATION INSTRUCTIONS I.D. 1089, REV. F

DE5300 Delayed Egress System. General Information

Mechanical to Electrical Making the Jump

Exit Switches 410 & 420 SERIES MODELS SPECIFICATIONS HOW TO ORDER 1 SPECIFY MODEL 2 SPECIFY FINISHES 3 SPECIFY OPTIONS

Mechanical to Electrical Solutions. for Aluminum and Glass Openings

Circuits, Diagrams & Power. Rodger Schmidt ASSA ABLOY EMSO Group HES/Folger Adams/Securitron/Adams Rite/Alarm Controls

ED4000. Narrow Stile Pushpad Exit Devices

22-F fire exit rim device for all types of 4 x 8 (1219mm x 2438mm) single doors and 8 x 8 (2438mm

Installation Instructions

SECURITRON MODEL XMS EXIT MOTION SENSOR INSTALLATION AND OPERATING INSTRUCTIONS

Alarmed Exit Hardware

INSTALLATION INSTRUCTIONS 101-DE/101-KDE

1.800.MAGLOCK SECURITRON.COM GATE & FENCE

ABLOY EFEND. New name for security

Code Compliance. Selected Exit Check models are available to comply with one or more codes listed below. See Operation on page 3.

FIREFLY II PLUS RELEASE DEVICES INSTALLATION MANUAL

Remote Chexit Module (RCM) System. General Information

Fire Burglary Instruments Inc. XL-2G Gold Control/Communicator Installation Training Seminar Rev. 5/96

RELEASE DEVICE CONTROLS

631RF Amp Power Supply

# amp # amp 12/24 VDC POWER SUPPLY INSTALLATION MANUAL. 4202/4MA, Rev. E 0804

SECTION DOOR HARDWARE

Commercial and Light Industrial Fire Alarm Control Panel

5900 SERIES Low Energy Power Operator

LOCK INTO THE ACSI ADVANTAGE LOCK INTO THE ACSI ADVANTAGE

CM800 Emergency Call System

2408/2900. Fire Guard

4040 FM 535 F :

Pilfergard Door Alarms

F PC and AO OUTPUT BOARDS INSTRUCTION MANUAL. Blue-White. Industries, Ltd.

2409/2900. Fire Guard

Specification/ Data Sheet

TECHNICAL DATA OBSOLETE

Single Door 39.5 Right Hand Push AL. Double Door (Twin) 75.5 Push AL Simultaneous 92 Push 11 + reveal BZ Independent Max reveal on a pull 2.

RCR-REX Request-to-Exit Dual Technology Motion Sensor Installation Guide

CX-WC SERIES RESTROOM CONTROL KITS ELECTRIFIED LOCKS, RELAYS & TIMERS BARRIER FREE RESTROOM CONTROL FEATURES DESCRIPTION APPLICATION

ACDx10xE5000 Access Controlled Doors

PRICELIST Access. Value. Today.

THE "SS90" SERIES RELEASE DEVICES MODEL B2 INSTALLATION MANUAL

Addendum for STI-6406 with Dual Access Control

FireSystem 2000 Commercial and Light Industrial Fire Alarm Control Panel

CX-WC SERIES RESTROOM CONTROL KITS ELECTRIFIED LOCKS, RELAYS & TIMERS BARRIER FREE RESTROOM CONTROL FEATURES DESCRIPTION APPLICATION

Data Sheet Fire Safety & Security Products. System Overview. Initiating Circuits SXL-EX FACP 7906

APS-300 SERIES DUAL VOLTAGE UL 294 LISTED ACCESS CONTROL POWER SUPPLIES

SECTION INTRUSION DETECTION

EHT/EHTD. Electromechanical Closer-Holder Release Devices

Solutions for Hospital & Healthcare Facilities

MADE IN THE U.S.A. ADVANCE FIRE CONTROL MODEL LM21-AFC MANUAL RELEASE DEVICES TEST WEEKLY TO ASSURE PROPER OPERATION OF RELEASE DEVICE/CONTROL PANEL

2408/2900. Fire Guard. SARGENT Manufacturing Company 2004, 2007 All rights reserved

PLEASE READ ALL INSTRUCTIONS PRIOR TO INSTALLING THE SYSTEM. HANDLE THE EQUIPMENT CAREFULLY.

RESTROOM CONTROL KITS

DS3MX-E-I. Installation Guide. 3 Zone Mini Control Panel

DIVISION 8 OPENINGS SECTION OVERHEAD COILING FIRE DOORS. A. Section Metal Fabrications: Support framing and framed opening.

CX-29. Section 1 General Description. Section 2 Installation. Besam Switching Network & Bi-Directional Door Sequencer Installation Instructions

ML2000 Series. Mortise Locksets

Exit Check Integrated Delayed Egress Locks

120 VOLT POTENTIAL PRESENT. MAKE SURE POWER INPUT TO UNIT IS TURNED OFF DURING INSTALLATION AND WIRING PROCEDURE.

Installation/Owner s Manual Models 1504 / 1506

C E R T I F I C A T E O F C O M P L I A N C E

Exit Stopper. STI-6400 Series

EXIT CHECK DELAYED EGRESS LOCKS

Transcription:

Power Transfer Devices Door Cord (TSB-C) Simplest and most economical solution for power transfer Standard with Touch Sense Bar and MGL but may also be purchased separately Consists of an 18 [460mm] or 36 [920mm] armored stainless steel cable and plastic end pieces in two colors: light gray and black Cable has an interior diameter of.25 [6mm] Supports interior wire cables up to.2 [5mm] thick 1.2" [30mm] 1.2" [30mm] 18", 36" [460mm, 920mm ].88" [22mm] How To Order TSB-C TSB-CXL Electrical Power Transfer (EPT) Installs in the door and frame edges Accepts a thick cable and protects it within a flexible steel shield Near universal device that will work on any type of door hung using butt hinges, continuous hinges or pivots Will not function on a center pivot door Manufactured by Abloy Oy for Securitron EPT EPTL Door Cord With Gray/Black Caps 18" Cord Door Cord With Gray/Black Caps 36" Cord Electrical Power Transfer Electrical Power Transfer, Long 9.8" [249mm] 18.07" [459mm] 12.72" [323mm].88" [22mm] 21.38" [543mm].67" [17mm] 55

800-MAGLOCK 800-624-5625 WWW.SECURITRON.COM Power Transfer Devices Electric Hinge (EH) Transfers power with the highest level of concealment Produces the most aesthetically pleasing installation Two different electric hinge configurations: 4 1/2 x 4 (model EH-40) 4 1/2 x 4 1/2 (model EH-45) Manufactured by McKinney Hinge 500mA current carrying capability 6 conductor, 28 gauge wire 4.5" [114mm] 4", 4.5" [102, 114mm] LED Monitors Zone Light Panels (ZLP) Provides visual status of a lock or other device Stainless Steel Face Plate 1.75" [44mm] How To Order EH-40 EH-45 How To Order ZLP-1 ZLP-2 ZLP-4 Electrified Hinge 4.5" x 4" Stainless 5 Wire Electrified Hinge 4.5" x 4.5" Stainless 5 Wire 1 Set of Red & Green LEDs, Narrow Stile 2 Sets of Red & Green LEDs, Single Gang 4 Sets of Red & Green LEDs, Double Gang 2.75" [70mm] 4.5" [114mm] 4.5" [114mm] 56 ZLP-1 ZLP-2

Timers Prime Time Digital Timer (DT-7) Application - Used to turn electric locks or other security systems on and off at programmed times. 2.5" [63mm] 7-day digital timer 10 Amp DPDT relay can be operated in toggle or pulse mode 12 programmed on/off times set daily (6 on, 6 off), on selected days, or on blocks of days First Man In feature delays operation until an external switch changes state and automates holiday programming in many applications 12 or 24 VAC or VDC AA battery provides backup to the display module program memory 7" [178mm] Time Mate Timer (TM-9) 3.19" [81mm] DT-7 Prime Time 7 Day Digital Timer Application - When used with a momentary keyswitch or pushbutton, the TM-9 will unlock a door for the timer's pre-set time. Miniature timer extends momentary switches up to 36 seconds Commonly used in outlet boxes with keyswitches or push buttons Fits in the backbox or can be mounted separately with double stick tape 3 Amp SPDT relay energizes for 2 to 36 seconds Time setting is selected by DIP switches rather than by a pot Applications include releasing electric locks and shunting alarm contacts 12 or 24 VDC.75" [19mm] 2" [52mm] 1" [25mm] TM-9 Time Mate Timer 57

800-MAGLOCK 800-624-5625 WWW.SECURITRON.COM Electronics Time Master II Multi Function Timer (TM-2) Application - The ideal solution for unusual time sequencing requests like bank or ATM vaults. Industrial quality multi-function timer 12 or 24 VAC or VDC with 5 Amp DPDT relay output DIP switches select delay times of 1 to 255 seconds or minutes Seven operating modes: ON delay (timer is powered; relay energizes after delay and resets when the timer is unpowered) Triggered ON delay (same operation started from external switch) OFF delay (timer is triggered; relay energizes immediately and 2.5" [63mm] 4.125" [105mm] 3.187" [81mm] BA-XDT resets after delay) One shot (non-retriggerable OFF delay) Toggle (trigger closure energizes relay; next closure reset etc.) Cyclic (relay cycles on and off at time interval set) Pulse output (relay pulses for 1/4 second as external switch changes state) Triggering can be from an N/O or N/C switch Includes a flashing LED drive output providing visual indication of the time remaining TM-2 Time Master II Multi Function Timer Exit Delay Timers Meet all code requirements including the BOCA 30 second relock function Nuisance delay and release times are digitally set using precise DIP switches Supplied alone, or in an enclosure mounted with SonAlert BA-XDT is a surface mount box FA-XDT is a flush mount plate 5 Amp relay UL Listed 5.25" [133mm] XDT-12 Exit Delay Timer 12VDC FA-XDT XDT-24 Exit Delay Timer 24VDC BA-XDT-12 Exit Delay Timer Surface Mount Box 12VDC BA-XDT-24 Exit Delay Timer Surface Mount Box 24VDC 58 5.25" [133mm] FA-XDT-12 FA-XDT-24 Exit Delay Timer Flush Mount 12VDC Exit Delay Timer Flush Mount 24VDC

Electronics Relay Logic Pack (RLP) Application - Can be used as a DPDT latching alarm relay or for two door interlocks (mantrap). Multi-function circuit pack Allows integration of lock status sensing outputs with access control systems requiring N/O or N/C dry status signals coupled with a delay before lock status changes state Creates a relay interlock circuit Creates an interlocked trap entry (when coupled with 2 electric locks) Can function as a DPDT relay with 1 Amp contacts Can provide time delay of door operator when electric lock is used 2" [51mm] 1" [25mm] Piezo (PZ1).80" [20mm] Application - Used as a remote alarm sounder for exit delay or remote door prop. Remote annunciator Powerful SonAlert sounder Stainless steel single gang plate 2.75" [70mm] RLP-12 Relay Logic Pack 12VDC RLP-24 Relay Logic Pack 24VDC PZ1 Piezo Single Gang 4.5" [114mm] 1.38" [35mm] 59

800-MAGLOCK 800-624-5625 WWW.SECURITRON.COM Electronics Relay Board (RB) Application - The RB4 board is used for interlock installations and where a basic relay board is needed. RB-4-24 RB-4-12 Relay Board 12VDC RB-4-24 Relay Board 24VDC DPA Add relays for uses including shunting, interlocking and reporting Individual coil connections - common negative or positive Replaces socket mount relays Mounts 4 DPDT relays with 2 Amp contacts All dry contact connections are brought out on screw terminals Relays have low current coils (13mA at 12VDC; 8mA at 24VDC) Allow operation from most LED drive outputs Door Prop Alarm (DPA) Application - The DPA is designed to detect and deter a door from being left propped open. Multi-functional control timer that operates as a door prop alarm Monitors whether the door has been propped open Can detect attempts to tamper with lock or door status Includes three outputs providing local and remote signaling Bypass mode for valid access/egress needs Duress alarm function when used with a N/O switch 5 Amp relay 12 or 24 VDC DPA-12 Door Prop Alarm 12VDC DPA-24 Door Prop Alarm 24VDC BA-DPA-12 Door Prop Alarm - enclosed 12VDC 60 BA-DPA BA-DPA-24 Door Prop Alarm - enclosed 24VDC

Door Position Switches Maximum Security Switches (MSS) Used to monitor the open/closed status of doors, windows, gates, machinery safety barriers or other moving assemblies Supplied in three versions for different environments: MSS-1 Door with hollow frame = MSS-1 provides a jacketed cable Other types of openings = MSS-1G includes a 3-foot [936mm] stainless steel cable Standard ANSI 4 7/8 strike cutout = MSS-1C is a concealed unit.75" [19mm].75" [19mm] 1.5" [38mm].75" [19mm] 4.25" [108mm] 4.25" [108mm] MSS-1C MSS-1G False alarm reduction Versatile indoor-outdoor application Optional remote test feature Main Output: SPDT at max of 125mA @24V or 250mA @12V Tamper Output: Closed when secure; open to alarm - 1 Amp max current Operating Temperature: -40 to +150F [-40 to +65C] Operating Gap: Optimum centered separation distance is marked on each unit. It is typically between.3 -.475 [8mm-12mm] ± tolerance around this optimum separation ranges from.2 [5mm] to.3 [8mm] Warranty::MagnaCare Lifetime Replacement Warranty MSS-1 MSS-1-RT MSS-1C MSS-1C-RT MSS-1G MSS-1G-RT High Security Switch Surface Mount High Security Switch Surface Mount Remote Test High Security Switch Concealed High Security Switch Concealed Remote Test High Security Switch Surface Mount Conduit High Security Switch Surface Mount Conduit Remote Test 61

800-MAGLOCK 800-624-5625 WWW.SECURITRON.COM Latch Monitors Latch Monitors (LML, LMS, LMD) Application - The LM Series is designed for reporting back to an alarm system to indicate that a door is latched, thereby reducing possible false alarms. Electronically verify mechanical latch and bolt positions Detect and report that a door is actually latched or bolted, not just closed Installs easily concealed behind existing hardware Require no jamb or strike plate modification LMS-1 includes a single SPDT switch and fits any standard 2 3/4" ANSI cut out LML-1 also has a single SPDT switch and fits any standard 4 7/8" ANSI cut out LML-2 monitors a mortise latch and deadbolt separately, has two separate SPDT switches, and fits any standard 4 7/8" ANSI cut out.85" [22mm] 3.43", 1.32" [87mm, 33mm] UL Listed 4.59", 2.56" [117mm, 65mm ] Contact Rating: SPDT 2 Amp @ 24V Operating Temperatures: -40 to +160F [-40 to +71C] Warranty:: MagnaCare Lifetime Replacement Warranty LML-1 Latch Monitor ANSI 4 7/8 LML-2 Latch Monitor ANSI 4 7/8 w/deadbolt LMS-1 Latch Monitor ANSI 2 3/4 Bolt Monitor (LMD-1) Can be used with an Adams Rite MS type deadlock Reports the locked or unlocked status of narrow stile aluminum frame doors, including sliding glass doors Installs quickly without routing Contact Rating: SPDT 2 Amp @ 24V Operating Temperatures: -40 to 160F [-40 to 71C] 1.38" [35mm] Warranty: MagnaCare Lifetime Replacement Warranty 62 1" [25mm] 1.37" [35mm] LMD-1 Latch Monitor for Aluminum Door Deadlock

Exit Motion Sensor - (XMS) Application - The XMS Passive Infrared Request-to-Exit Device is a motion detector specifically designed to reliably release magnetic locks. A person approaching the door is seen by the motion detector just before reaching the door. 1.75" [44mm] 7" [178mm] Features and Benefits Passive Infrared Request-to-Exit Device Designed to reliably release magnetic locks Automatically cuts power to the lock, allowing the individual to exit without even realizing that the door is secured. UL Listed Input voltage: 12 or 24 VDC Power draw: 20-50mA, depending on switching status Environment: Indoor use only Warranty: MagnaCare Lifetime Replacement Warranty 1.87" [48mm] XMS Exit Motion Sensor 63

800-MAGLOCK 800-624-5625 WWW.SECURITRON.COM Lock Control Panels Application - The LCP Series panel is designed to operate any DC electric lock or strike that operates on 12 or 24 VDC (fail safe or fail secure). Other electric locks can be accommodated by adding relays. Desktop Cabinet NEMA-1 Locked Wall Cabinet Flush Mount Wall Plate 19" Rack Panel (face mount) Each LCP Series panel is constructed of control zones supplied in multiples of four. A single multi-color monitoring LED per zone displays four possible conditions of the lock: Green shows that the zone is secure, and this may be driven from a door switch, lock status switch or the power status of the lock. Off shows that the lock has been legally released from either the panel control switch or from a remote switch at the door. In this condition, the toggle switch itself illuminates yellow. Red is the alarm condition showing that a lock which should be secure is not reporting secure. This condition is latching and is reset from a momentary switch once the zone has been resecured. A Sonalert accompanies the red violation condition. Orange shows that the zone has been resecured and is ready for alarm reset. After reset, the indicator turns green again. Current draw: Depends on version: 60mA maximum per zone. Switching Capability: Lock current is maximum 1.5 Amps with 3 Amp inrush acceptable Power: Panel available for 12 or 24 VDC operation. Unregulated voltage is acceptable. UL Listed: USA & Canada: SA6635 and BP7041 Dimensions (H x W x D) Desk Mount: 4-8 zones: 5 x 11 3/4 x 13 3/4 [127mm x 299mm x 349mm] 12-24 zones:5 x 16 3/4 x 13 3/4 [127mm x 425mm x 349mm] Rack Mount: (H x W) 4-12 zones: 5 1/4 x 19 (3U) [133mm x 483mm] 16-24 zones: 10 1/2 x 19 (6U) [267mm x 483mm] 64 Wall Mount: 4 zones: 10 x 10 x 4 [254mm x 254mm x 102mm] 8-16 zones: 12 x 12 x 4 [305mm x 305mm x 102mm] 20-24 zones: 16 x 12 x 6 [406mm x 305mm x 152mm] Flush Mount: (Cutout) 4 zones: 10 x 8 x 4 [254mm x 203mm x 102mm] 8-16 zones: 12 x 12 x 4 [305mm x 305mm x 102mm] 20-24 zones: 18 x 12 x 4 [457mm x 305mm x 102mm]

Lock Control Panels Each LCP is made to customer specifications. Please contact factory for exact quotation. LCP Lock Control Panel Zone requirements 4 to 24 zones per panel Voltage 12 or 24 VDC Upgrade Options see below Mounting D Desktop Cabinet W NEMA-1 locked wall cabinet R 19" rack panel (face mount) F Flush mount plate with back box For example: LCP-4-12-R-AM = LCP, 4 zones, 12VDC, additional monitoring lights option, rack mount LCP-12-24-W = LCP, 12 zones, 24VDC, wall cabinet mount Upgrade Options SLR - Silence latch with recurrent reminder signal This option adds a momentary illuminated button which is used to silence the Sonalert only after it has sounded. When the Sonalert has been silenced the button illuminates and a built-in reminder tone is emitted. Once the alarm condition is cleared, the silence function automatically resets so that Sonalert will sound again for the next alarm event. ER - Emergency all release (fail safe locks only) This option adds an alternate action illuminated button which, when pressed, illuminates and immediately releases all locks. Pressing the button again restores power to the locks. This option is used only with fail safe locks. AM - Additional set of monitoring lights (per four zones) This option adds a second LED (yellow) to each control zone. The LED illuminates from an external closure or voltage input and at the same time, a pulsing Sonalert sounds. The most common use for this option is to annunciate the start of exit delay for a fail safe lock in the NFPA 101 delayed exit installation. Other conditions, depending on the specific job, can also use this capability. KB1 or KB2 - Key switch control bypass The bypass keyswitch, when turned off, secures all zones and shunts out the control switches and emergency release button (if one has been supplied) so that the panel may be left unattended for a time. This option yields a mortise cylinder type keyswitch with cylinder supplied. The suffix 1 is wired for fail safe locks. The suffix 2 is wired for fail secure locks. MOM - Momentary Control Switches (Alternate is standard) This option changes the lock control toggle switches from alternate (standard) to spring loaded momentary. It is used if the installation permits only momentary release of a lock from the panel. (Momentary switches are not illuminated) HT - Heavy duty push button switches (per four zones) The standard toggle switches are limited in life to about 30,000 operations. This is more than adequate for most installations where the panel switches are used sporadically but for high volume use, we suggest push button switches, with a life of about 200,000 operations. 65