Freedom Line RFMN. Certified. with INNOVATOR Doors Medium Temperature Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount

Similar documents
Freedom Line RFM. Certified. with INNOVATOR Doors. Medium Temperature Technical Data Sheet P/N _B NSF. Freedom Line merchandisers are top mount

Freedom Line RFLN. Certified. with INNOVATOR Doors. or INNOVATOR III Doors Low Temperature Technical Data Sheet P/N _J NSF

Freedom Line RFLNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

Freedom Line RFMNS. Certified. with INNOVATOR Doors. Technical Data Sheet P/N _J NSF. Freedom Line merchandisers are top mount.

RM with INNOVATOR Doors

RL with INNOVATOR II No Heat Doors

Engineering Plan Views

RMN with INNOVATOR Doors Technical Data Sheet

P1NX-E P/N _G NSF. Certified. Technical Data Sheet. October 2016

RLNIE with INNOVATOR II

P/N _K NSF. Certified. Technical Data Sheet. March Spanish P/N Item Part # Description Wiring Item #

RLNI with P/N _J NSF. INNOVATOR Doors or. INNOVATOR III Doors. Certified. Technical Data Sheet. January 2018

F-L P/N _C NSF. Certified C A. Technical Data Sheet. March Item Part # Description Wiring Item # Item Part # Description Wiring Item #

FG-L P/N _C NSF. Certified. Technical Data Sheet. March 2017 H C K B. Item Part # Description Wiring Item #

RLTIM with P/N _H NSF INNOVATOR. Certified. & INNOVATOR III Doors Technical Data Sheet. January 2018

PWWEE P/N _C NSF. Certified. Technical Data Sheet. October 2016

RLT with INNOVATOR Doors

FIG P/N _K NSF. Certified March 2017 J A F E B I. Technical Data Sheet. Spanish P/N

PWEE Technical Data Sheet

FIG-L P/N _F NSF. Certified January 2018 H C A L B. Technical Data Sheet

FWEL P/N _D NSF E D C H B A F. Certified January Technical Data Sheet. Item Part # Description Wiring Item #

FG-L Technical Data Sheet

P/N _F NSF Certified June 2010

FWG P/N _M NSF. Certified. DOE 2012 Energy Efficiency Compliant F J G I. Technical Data Sheet. June Data sheet-excel FWG.

FWG-L. Certified. DOE 2012 Energy Efficiency Compliant. Technical Data Sheet P/N _D NSF. May Spanish

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

LifeLine Premier RLNIE

BEXD-8A. Certified. Spanish P/N Technical Data Sheet P/N _C NSF. March 2017

Excel FWGH P/N _F NSF. Certified. Frozen. January Merchandiser Data Sheet

FWG P/N _G. NSF Certified December Technical Data Sheet F J G I P/N _G. Item Part # Description Wiring Item #

EXCEL FWEGH-L P/N _F NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

EXCEL FWEGH P/N _D NSF. Certifi ed. Frozen. March Merchandiser Data Sheet

M1GLE-93. P/N _G NSF Certified A E P/N F. Technical Data Sheet. July Item Part # Description Wiring Item #

P/N _D NSF. Certified. Frozen. May Merchandiser Data Sheet

Nosing Heater. Return Grill Heater

LNG P/N _H. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _H. Item Part # Description Wiring Item #

P/N _G. NSF Certified February 2007 C A F G H. Technical Data Sheet P/N _G. Item Part # Description Wiring Item #

RLNIE P/N G. P/N _G NSF Certified. Technical Data Sheet. Warning: Terminal block NOT for case-to-case wire connection!

BEXD-8A. P/N _A NSF Certified P/N_ _A C B P E D K. Technical Data Sheet. November 2010

LWU Technical Data Sheet

RL with INNOVATOR Doors

RFLN & RFMN Freedom Line

RFLNS, RFMNS & RFLTM Freedom Line

SSGB. EPH Certified to NSF-7 G B. Technical Data Sheet P/N _E. January Data sheet-excel SSGB

ISF and ISM. Low and Medium Temperature Remote and Self Contained Island Merchandisers. Installation & Service Manual IMPORTANT

ON3.5EM-NRG ON3.5EM-NRG. Narrow Multi-Deck Merchandiser with Synerg-E End Cap (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT GENERAL NOTES:

O4ID O4ID. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) ENGINEERING REFERENCE SHEET NOTES

Reach-in Merchandisers

6RZLH 6RZLH. Reach-In Merchandiser 2, 3, 4 & 5 Door (Frozen Food) REFERENCE NOTES FOR ENGINEERING DATA

MD Medium Temperature Self Contained Open Vertical Merchandisers

ON4UM-NRG ON4UM-NRG. Narrow Multi-Deck Merchandiser 4', 6', 8', 12' (Dairy/Deli/Produce) SHIPPING WEIGHT GENERAL NOTES

L3MGB. THREE DECK MEAT/DELI MERCHANDISERS Medium Temperature Self Serve Display Cases

GSVM Medium Temperature Self Contained Open Vertical Merchandisers. Installation & Service Manual

OHMH-NRG OHMH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

O3UM-NRG O3UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 10', 12' (Dairy/Deli/Meat/Produce) SHIPPING WEIGHT

6DMLH-NRG 6DMLH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT GENERAL NOTES

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for

FIELD-INSTALLED MOTION ACTIVATED LED DIMMER CONTROL

Self-Contained MERCHANDISERS. February

OPTIONAL MOTION ACTIVATED LED DIMMER CONTROL

OIM OIM. Medium Temp Island Merchandiser 8' & 12' (Deli / Meat) REFERENCE NOTES FOR ENGINEERING DATA:

MD Medium Temperature Self Contained Open Vertical Merchandisers

Installation & Service Manual

OPTIONAL CONTROLLER. Kit P/N _A. December 2016 ANTI-CONDENSATE HEATER FOR REACH-IN GLASS DOORS. Spanish French

O5MH-NRG O5MH-NRG. High Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT

O5M-NRG O5M-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Deli / Meat) SHIPPING WEIGHT GENERAL NOTES

Medium Temperature Bulk Produce and Bakery Merchandisers

JUMBO ISLAND FROZEN FOOD/ICE CREAM/MEDIUM TEMP MERCHANDISERS Low, Medium and Dual Temperature Self Serve Display Cases

O5DM-NRG O5DM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8' & 12' (Beverage / Dairy / Deli / Produce) SHIPPING WEIGHT Case Weight O5DM-NRG ---

Installation & Service Manual

HGM-1, 2 & 3 BS, TS. Bottom / Top Mount Medium Temperature Remote and Self Contained. Installation & Service Manual. Glass Door Merchandisers

EcoShine II Horizontal LEDs for Multi-Deck Merchandisers Shelf, Rail and Canopy

EcoVision Door Manual

KRSCP Self-Contained Walk-In Unit Installation and Service Manual Addendum

Medium Temperature. Installation & Operation Manual Shipped With Case Data Sheets. IMPORTANT Keep in store for future reference!

NFW, NCW, NFWG, NCWG, NFWE, NCWE

Installation & Service Manual

Self-Contained MERCHANDISERS. October

BCH Medium Temperature Merchandisers

L6FA. MULTI-SHELF FROZEN FOOD MERCHANDISER Low Temperature Self Serve Display Cases

HGL- 1, 2 & 3 BS, TS. Bottom / Top Mount Low Temperature Remote and Self Contained Glass Door Merchandisers. Installation & Service Manual IMPORTANT

O2.5UM-NRG O2.5UM-NRG. Multi-Deck Merchandiser with Synerg-E 4', 6', 8', 12' Case (Dairy/Deli/Meat/Produce/Seafood)

F-6 Multi-deck Frozen Food Wall Merchandisers

VNRZH VNRZH. High Narrow Reach-In Merchandiser 1, 2, 3, 4, & 5 Door (Frozen Food) SHIPPING WEIGHT Case Weight VNRZH LBs GENERAL NOTES

P/N _B September Field Installed Dual Temp Operation E P R Controlled (Evaporator Pressure Regulator)

Service Merchandisers

Installation & Service Manual

Rear Roll-in Dairy Medium Temperature Free Standing or Suspended Merchandisers Installed in Walk-in Cooler Exterior Walls

Ultra Low Front Rear Load Medium Temperature

Low Temperature. Installation & Operation Manual IMPORTANT. Single Deck Wall & Island Merchandisers. Keep in store for future reference!

Self-Contained Medium Temperature Delicatessen, Dairy, Meat, Produce and Bakery Merchandisers

EcoVision II Plus Door Upgrade for D6 Kysor Warren Multi-deck Merchandisers

SERIES NAV S Display Merchandisers

Glass Lids for Low Temperature Single Deck Wall & Island Merchandisers

LTH Low Temperature Merchandisers

Service Merchandisers

ORB ORB. Reach-In Merchandiser 1, 2, 3, 4, 5 & 6 Door / 4', 6', 8' & 12' (Beverage / Dairy / Deli / Meat)

ISF and ISM Low and Medium Temperature Self Contained Island Merchandisers

N5FGA, N5NGA, N5FGNA, N5NGNA

Parallel Rack Systems

Transcription:

Freedom Line merchandisers are top mount refrigeration ready Freedom Line RFMN with INNOVATOR Doors NSF Certified January 18 OPTIONS SHOWN: Lighted Facades Warning: Terminal block NOT for case-to-case wire connection! We reserve the right to change or revise specifications and product design in connection with any feature of our products. Such changes do not entitle the buyer to corresponding changes, improvements, additions or replacements for equipment previously sold or shipped. Item Part # Description Wiring Item # Item Part # Description Wiring Item # Fan Assemblies, and Thermostats A. 12W Standard Energy Efficient Fan Assembly (1) 0477655 Fan Motor, Evaporator 0461805 Fan Blade Control Panel B. 3007826 Dixell XR75 Control (2) C. 0334802 Dixell Discharge Air Sensor (3) D. 0334802 Dixell Defrost Sensor (4) LED Fixtures and Power Supply H. 0499399 Power Supply (7) I. Door Lamp, LED BU.4440877 4100K Center (8) BU.4440878 4100K End (9) J. Facade Lamp, LED (10) BU.4441411 2900K 29.5 In. Length BU.4441412 2900K 30.5 In. Length Refrigeration E. 0516897 Condensate Pump (5) F. 0538255 Condensate Pan & Heater (6) (Evapoway) G. 0460992 TEV 2 Door Models 0460993 TEV 3-4-5 Door Models Refer to Innovator Reach-In Glass Door Installation and Service manual, P/N 0425683, for Innovator and Innovator II door and frame replacement parts. Data sheet-lifeline RFMN Note: Revision J: Updated controller information. Other changes marked with a bar, circle or underline. 18 HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. U.S. & CANADA 1-800-922-1919 MEXICO 1-800-890-2900 WWW.HUSSMANN.COM Spanish P/N 0537772

Engineering Plan Views Freedom Line RFLN - RFMN Plan View 09-13 PHYSICAL DATA Merchandiser Drip Pipe (in.) 1 1 /4 Merchandiser Liquid Line (in.) 3 /8 Merchandiser Suction Line (in.) 5 /8 Freedom Line Standard Narrow Footprint Plan View 2, 3, 4 & 5 Door Dimensions shown as inches and (mm). 4 in. (102 mm) Minimum Air Gap from Merchandiser Insulated Panel to Wall or Flat Surface Maintain air circulation to reduce condensation. A C 11 (279) E 7 (8) Skid/ External Base Waste Outlet 48 (19) 6 (152) Bottom Front Support Top Mount Electrical Box Approximate Location (508) 30 5 /8 (778) 39 3 /4 (1010) Electrical Wireway Splashguard Water Seal (see note **) Relay & Terminal Block Location 66 1 /4 (1683) 26 1 /2 (673) Front 5-Door Shown Door Swing Clearance Freedom Line Narrow Footprint Plan View 1, 2 & 3 Door Dimensions shown as inches and (mm). A 4 in. (102 mm) Minimum Air Gap from Merchandiser Insulated Panel to Wall or Flat Surface C 26 1 /4 (667) 15 1 /4 (387) 12 (305) 7 (8) 37 5 /8 (956) Skid/ External Base Bottom Front Support 48 (19) 6 (152) Top Mount Electrical Box Approximate Location (508) 30 5 /8 (778) 39 3 /4 (1010) 12 7 /8 (327) Shelf Area Electrical Wireway Waste Outlet Splashguard Shelf Area 51 3 /4 (1314) 10 3 /4 (273) Water Seal (see note **) Relay & Terminal Block Location 78 1 /4 (1988) 26 1 /2 (673) Front 4-Door Shown Door Swing Clearance 2 of 11 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 Freedom Line RFMN with Innovator Doors

Plan View Dimensions Freedom Line RFMN 2 Dr 3 Dr 4 Dr 5 Dr General (A) Merchandiser Length 62 (1575) 92 1 /2 (2350) 122 7 /8 (31) 153 3 /8 (3896) **NOTE: Each solid end adds approximately 2 3 /8 in (60 mm) to length of line up; each partition add approximately 2 3 /4 in (70 mm); case to case joints can add approximately 1 /8 in (3 mm) for gasket material. Maximum O/S dimension of merchandiser back to front *** 39 3 /4 (1010) 39 3 /4 (1010) 39 3 /4 (1010) 39 3 /4 (1010) *** Add 26 1 /2 in. (673 mm) for door swing. Back of merchandiser to rear of splashguard 35 7 /8 (911) 35 7 /8 (911) 35 7 /8 (911) 35 7 /8 (911) Width of Skid rail 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) 3 3 /4 (95) Width of Bottom Front Support 6 (152) 6 (152) 6 (152) 6 (152) Stub-up area between front support and splashguard 3 1 /8 (79) 3 1 /8 (79) 3 1 /8 (79) 3 1 /8 (79) Electrical Service (dimensions are approximate) (B) RH end of merchandiser to center of Electrical Service Area 11 (279) 11 (279) 11 (279) 11 (279) Back O/S of merchandiser to center of Electrical Service Area (508) (508) (508) (508) * NOTE: Electrical Field Wiring Connection Point is at top of merchandiser. Waste Outlet (C) Right end of merchandiser to center of waste outlet 23 7 /8 (606) 54 1 /4 (1378) 46 1 /4 (15) 76 5 /8 (1946) Water Seal Edge of water seal to center of waste outlet 13 (330) 13 (330) 13 (330) 13 (330) Schedule 40 PVC drip pipe 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) 1 1 /4 (32) ** NOTE: Field installed water seal outlets, tees, and connectors are shipped with merchandiser. Refrigeration Outlet (D) RH end of merchandiser to center of refrigeration interface Back O/S of merchandiser to center of refrigeration interface * NOTE: Refrigeration interface is at top of merchandiser. Outside bottom front supports from end of merchandiser 7 (8) 7 (8) 7 (8) 7 (8) 37 1 /2 (952) LH Center bottom front support from Centerline 24 (610) 24 (610) 24 (610) 24 (610) Distance between Center and Outside supports will vary (E) Depth when disassembled for door entry 35 1 /2 (902) 35 1 /2 (902) 35 1 /2 (902) 35 1 /2 (902) HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 3 of 11

Freedom Line RFMN (508) to (533) Facade (Installed Position) 102 1 /2 (2603) to 103 1 /2 (2629) Installed in. Straight Facade Facade in Cross Section 4 of 11 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 Freedom Line RFMN with Innovator Doors

Freedom Line Narrow Footprint Reach-in Top-Mount-Refrigeration Ready 2, 3, 4 and 5 Door Models Standard Reach-in configuration consists of Innovator I doors, energy efficient fan motors, and EcoShine II LED vertical lighting. Hussmann refrigerated merchandisers configured for sale for use in the United States meet or surpass the requirements of the DOE energy efficiency standards. Provide adequate clearance for air circulation at rear to reduce condensation. Dimensions shown as inches and (mm). Note: An optional Louvered Facade Panel kit is available that will allow for the top spacing minimum clearance of 3 inches (76 mm). Note: Facade is field-installed. Electrical connection box, external supports, door handle and front raceway may be removed to facilitate passage through door way. Freedom Line RFMN REFRIGERATION DATA Note: This data is based on store temperature and humidity levels that do not exceed NSF guidelines. MEDIUM TEMP AHRI Rating Discharge Air F 32 36 Evaporator F 27 32 Unit Sizing F 25 30 (508) to (533) Ceiling 5 1 /2 (140) Minimum 2 1 /8 (54) 7 x 10 x 2 1 /2 Electrical Field Connections 37 (940) 36 1 /4 (924) in. Facade Shown Refrigeration Interface and Electrical Field Wiring Connection are at Top (508) 4 in. (102 mm) Required Air Gap 2 5 /8 (67) 102 1 /2 (2603) to 103 1 /2 (2629) Installed Btu/hr/Door NSF Type I NSF Type II AHRI Rating Temp ( F) /R.H. 75 / 55% 80 / 55% Innovator Parallel 480 505 470 Conventional 500 525 490 Average evaporator temperature shown. Use dew point for high glide refrigerants for unit sizing. Care should be taken to use the dew point in PT tables for measuring and adjusting superheat. Adjust evaporator pressure as needed to maintain discharge air temperature shown. 82 1 /4 (89) 65 1 /2 (1663) Door 67 (02) Frame 62 1 /2 (1588) 82 3 /4 (02) DEFROST DATA Frequency (hr) 24 Defrost Water (lb/dr/day) 0.36 (± 15% based on case configuration and product loading.) Offtime Temp Term ( F) 48 Failsafe (minutes) 40 22 Shelf (559) CONVENTIONAL CONTROLS Cut In Cut Out 6 1 /4 (159) 13 1 /8 (333) 4 3 /4 (1) 3 7 /8 (97) 23 5 /8 (600) Fan Coil 30 5 /8 (778) 35 7 /8 (911) 39 3 /4 (1010) NSF Certification This merchandiser model is manufactured to meet NSF/ANSI (National Sanitation Foundation) Standard #7 requirements for construction, materials & cleanability. HPC (psig) 3 395 LPC (psig) 15 5 Working charge with recommended Condensing Unit installed: 2Dr 2.3 lb 37 oz 1.0 kg 3Dr 3.2 lb 51 oz 1.5 kg 4Dr 3.7 lb 59 oz 1.7 kg 5Dr 6.8 lb 109 oz 3.1 kg based on 27ºF ( 2.8ºC) Evaporator temperature for medium temperature applications. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 5 of 11

Freedom Line RFMN Hussmann recommends against frame heater cycling with Innovator doors or Innovator III doors to prevent door seals from freezing to the frames and tearing. Electrical Data 2Dr 3Dr 4Dr 5Dr Number of Fans 12W 2 3 4 5 Amperes Watts Merchandiser 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr Energy Efficient Evaporator Fan 1V 50/60Hz Innovator 0.60 0.90 1. 1.50 36 54 72 90 Door Anti-sweat Heaters (on fan circuit) 1V 50/60Hz Innovator N/A Frame Anti-sweat Heaters (on fan circuit) 1V 50/60Hz Innovator 0.39 0.59 0.79 0.99 47 71 94 118 Heated Condensate Pan 5.0 5.0 5.0 5.0 600 600 600 600 Condensate Pump 1.9 1.9 1.9 1.9 87 87 87 87 Defrost Drain Heaters (1V) N/A 1V Circuit (Fans, anti-sweat heaters, drain pan heater, condensate pan heater, condensate pump, and standard Ecoshine 2 LED s) (standard) 8.0 8.8 9.6 10.5 813 877 939 1003 Maximum Overcurrent Protection Device (MOPD) Standard Vertical LED Lighting 2Dr 3Dr 4Dr 5Dr 2Dr 3Dr 4Dr 5Dr Hussmann EcoShine II - A (1V) 0.31 0.46 0.62 0.77 37.1 55.6 74.2 92.7 Notes: 1. Electrical input for the RFMN Freedom cases require two electrical connections at the top of the case: one 1V connection for the RFMN and one 8/230V or 1V connection for the condensing unit. 2. The condensing unit amps must be used to calculate the total electrical load. Refer to the condensing unit data sheet. A qualified electrician should perform all wiring in accordance with the NEC code and/ or all local codes. Wire sizing must take into account the total distance from the electrical panel to the Freedom case. 6 of 11 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 Freedom Line RFMN with Innovator Doors

Product Data Recommended Usable Cube 1 (Cu Ft/Dr) AHRI Total Display Area 2 (Sq Ft/Dr) Shelf Area 3 (Sq Ft/Dr) Freedom Line RFMN 22.80 ft 3 /Dr (0.65 m 3 /Dr) 13.04 ft 2 /Dr (1. m 2 /Dr) 28.50 ft 2 /Dr (2.65 m 2 /Dr) 1 AHRI Refrigerated Volume less shelving and other unusable space: Refrigerated Volume/Unit of Length, ft 3 /ft [m 3 /m] 2 Computed using AHRI 10 standard methodology: Total Display Area, ft 2 [m 2 ]/Unit of Length, ft [m] 3 Shelf surface area is composed of bottom deck plus standard shelf complement, as shown in the Hussmann Product Reference Guide. The standard shelf complement for this model is (5) rows of 22-inch shelves. ESTIMATED SHIPPING WEIGHT 4 2 Dr 3 Dr 4 Dr 5 Dr Solid End (each) Standard Freedom Line Merchandiser (18-Inch Facade, no Arch) lb (kg) 1005 (456) 1262 (572) 1688 (766) 70 (939) 74 (34) 4 Actual weights will vary according to optional kits included. HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 7 of 11

Freedom Line RFMN Fan and Heater Circuits Offtime Defrost (Standard) CIRCLED NUMBERS = PARTS LIST ITEM NUMBERS R = P = Purple 2P = Purple (2 Bands) DB = Dark Blue BK = LB = Light Blue Pink = Pink BR = Brown Y = Yellow OR = Orange W = THESE ARE MARKER COLORS (WIRE MAY VARY). 1V Power 1V Neutral 14 BR Evaporator Fans 1 BR 26 15 11 2P Frame Heaters 2P 23 22 Refer to Innovator Reach-In Glass Door, Installation and Service manual, P/N 0425683, for Innovator door and frame replacement parts. 12 1V Power 1V Neutral OR Switch Refer to Innovator Door Manual for Lighting Diagrams OR with Offtime Defrost Terminal Blocks in Wireway P BR OR OR P BR 11 12 14 22 26 WARNING All components must have mechanical ground, and the merchandiser must be grounded. = 1V Power = 1V Neutral = Field Ground = Case Ground 8 of 11 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 Freedom Line RFMN with Innovator Doors

Freedom Line RFMN or Innovator III Doors DPST SWITCH 26 23 1V 22 NEUTRAL 15 GROUND 4 3 D/A TEMPERATURE SENSOR DEFROST TERMINATE SENSOR 5 24 23 22 19 18 16 XR75CX 8 7 6 5 4 3 2 1 BLUE COMPRESSOR RELAY FIELD INSTALLED CONDENSING UNIT N 14 13 12 11 10 L GFCI OUTLET CONNECT TO LEADS PROVIDED ON TOP OF CASE CONDENSATE PAN HEATER 7 14 26 FANS LIGHTS & A/S 1 V 1 V LIGHTS FANS N & A/S N CONDENSATE WATER PUMP 6 3007295_B RACEWAY Dixell Wiring Diagram Reach-in with 2 or 3 Doors HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 9 of 11

Freedom Line RFMN RED RED 26 23 22 L1 L2 8 V 1 PHASE 60 HZ INPUT 15 GROUND 14 13 12 11 1V 1 V NEUTRAL D/A TEMPERATURE SENSOR DEFROST TERMINATE SENSOR 24 23 22 19 18 16 XR75CX 8 7 6 5 4 3 2 1 BLUE COMPRESSOR RELAY RED RED L1 10 DISCONNECT SWITCH FIELD INSTALLED CONDENSING UNIT L2 GFCI OUTLET CONNECT TO LEADS PROVIDED ON TOP OF CASE CONDENSATE PAN HEATER 14 26 FANS & A/S 1 V LIGHTS 1 V LIGHTS N FANS & A/S N CONDENSATE WATER PUMP 3007296_B RACEWAY Dixell Wiring Diagram Reach-in with 4 or 5 Doors 10 of 11 U.S. & Canada 1-800-922-1919 Mexico 1-800-890-2900 Freedom Line RFMN with Innovator Doors

Optional Lighting LED Fixtures Hussmann Light Switch Input 16 15 Output Wireway Blue Terminal Block Freedom Line RFMN EcoShine 2 Door LED Light Wiring Diagram Light Switch 16 16 Wireway Input 15 Output Blue Terminal Block 3 Door LED Light Wiring Diagram Light Switch 16 16 16 Input Blue Output Terminal Block 15 Wireway 4 Door LED Light Wiring Diagram Light Switch 11 10 10 10 10 11 Wireway Input 9 Output Blue Input 9 Output Blue Terminal Block 5 Door LED Light Wiring Diagram WARNING All components must have mechanical ground, and the merchandiser must be grounded. Circled numbers = Parts List Item Numbers R= Y = Yellow G = Green BL = Blue BK = W = = 1V Power = 1V Neutral = Field Ground = Case Ground HUSSMANN CORPORATION BRIDGETON, MO 63044-2483 U.S.A. WWW.HUSSMANN.COM 11 of 11