Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring

Similar documents
Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Hygro and hygrothermo transducers (capacitive) for HVAC monitoring

Hygro and Hygrothermal Transducers (Capacitive) for Air Conditioning Applications

Hygro and Hygrothermo Transducers (capacitive) for climatic applications

HT-1300 Series. Temperature and Humidity Duct Sensor. Product Bulletin. Power Supply VDC / 24 VAC. Humidity Accuracy 2.5% RH from 10 to 95% RH

Hygro/hygrothermal transducers (hygrometric)

It offers easy installation and the possibility for fast exchange of the sensor unit for service purposes.

Duct Sensors. Siemens Building Technologies HVAC Products. Symaro. for relative humitidy (high accuracy) and temperature

Duct Humidity and Temperature Sensors 0-10 Vdc or 4-20 ma Outputs Passive sensor PT1000, PT100 NTC, NI1000 etc. Features. IP65 protection.

Duct Air Quality Sensors

Hygro/hygrothermal transducers (hygrometric)

Duct Humidity and Temperature Transmitter. Features. IP65 protection. Ordering

Room Sensors. Building Technologies HVAC Products ... Symaro. for relative humidity (high accuracy) and temperature

QPM21 Series Duct CO 2 and Air Quality Sensors

In order to minimize the impact of rain, snow, ice and solar radiation on the measurement the EE33-M must be mounted inside a radiation shield.

Room air quality sensors

for relative humidity and temperature with calibration certificates

Accuracy by Design Products for the HVAC Professional

EN - english. Instructions for installation and operation. Mobile humidity meter DP 207

HYGRASREG RELIABLE PROTECTION AGAINST HUMIDITY FÜHLBARE PRÄZISION PRODUCT RANGE > Mechanical > Electronic > Guards

Relative Humidity Transmitters

QFM21... Siemens Building Technologies HVAC Products. Symaro Duct Sensors. for relative humidity and temperature

CO2 transmitters TRANSMITTERS TO DETECT CARBON DIOXIDE (CO 2 )

Sensors and switches. Temperature, Pressure, Humidity, Air flow, CO 2., CO and NO 2

Lamp Supply (Recommended)

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Ventostat Wall Mount. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. GE Sensing & Inspection Technologies.

Hygrostats (hygrometric)

Air Quality Sensors. Particle Matter, CO 2, Humidity, Temperature and Dust Products. OEM Sensor Components for Air Quality and Environmental Control

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

QFM21... Duct Sensors. Building Technologies HVAC Products. Symaro. for relative humidity and temperature

Room Temperature Sensors

VALTRONICS IAQ Monitor

IR25 Dual Gas Series Datasheet

Using the Model 1500 Portable Chilled Mirror Hygrometer

R9900. Model. Instruction Manual. Indoor Air Quality Meter. reedinstruments. www. com

RH & T Sensors & Humidistats. RH-DT Duct Mount RH & T Sensors. Description

HYGROPHIL H process hygrometer

QFM41.. Duct sensors QFM41.. AQF4150 AQF3153. Symaro. for relative humidity and temperature with calibration certificates

QFM21... Duct sensors. Symaro. for relative humidity and temperature

QFM21... Duct Sensors. Siemens Building Technologies HVAC Products

Introduction Portable Meters Transmitter Probes RELATIVE HUMIDITY

MP 601A Humidity Probe INSTRUCTION MANUAL

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Technical Instructions Document No. CE1N1961 March 17, Room CO 2 and Air Quality Sensors. Description. Features. Application

INSTRUMENTATION AND CONTROL DEVICES FOR HVAC

for relative humidity and temperature

Duct Temperature Sensors

Room Air Quality Sensors

KANE-ALERT-CO 2 Monitor with Temperature

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

DESIGN MANUAL. The information in this doucment is applicable to sensors built in September, 2009 or later (Firmware 3.0)

Copying contents of this booklet or handing over to third party is strictly forbidden without written permission from Detector Oy.

Datasheet: K-22 LO Sensor

Complete packages with Software and Controller

gas monitoring system

SIMRAD GD10PE IR GAS DETECTOR

Ventostat Wall Mount. Amphenol Advanced Sensors. Telaire Wall Mount CO 2. , Humidity and Temperature Transmitters. Features:

IR15 Dual Gas Series Datasheet

STT 3000 Series STT250 Smart Temperature Transmitters Specifications Models STT25T EN0l-6091 February 2009

Dräger Polytron 5720 IR Toxic Gas Detection

Specifications: ACCURACY: RH: ±1% Temperature: ±0.5 C. Dew point: Typically, +/-2.0C above 0C; +/-3.0C 0 to -60C OPERATING RANGE:

DP 300 mobile dew point instrument

Dräger PIR 7200 Toxic Gas Detection Transmitter

Minimal maintenance requirements - No consumables and low cost of ownership. Rapid, accurate results - for safe operation of coal handling systems

FA compressed air plants (refrigeration/adsorption driers) - granulate driers - medical gases - non-corrosive gases, e. g.

WRF04 CO2. Application. Types Available. Security Advice Caution. Combined room sensor CO 2 / temperature / humidity. Datasheet

Product Catalogue. Air and Gas Sensors. Save Life and Energy

THM80X Series Operation Manual Industry Degree Temp. & Humidity Transmitter V 0.1

CMT MANUAL 6. NMC SENSORS

HYGROMER MP 100 A Meteorology probe

WRF04 CO 2 RS485 Modbus

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

A and B Series Sensors for humidity and temperature for digital transfer RS485 / MODBUS-RTU or RS232

Infrared Carbon Dioxide Sensor Module CM1106SL

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Setra Model SRH Relative Humidity Sensor Series with Active or Passive Temperature Sensing Installation Instructions

D Series Sensors for Humidity and Temperature Measurement With calibrated dmodul

TOXIC GAS AND OXYGEN DETECTOR DTX 420 INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS DTX420_MAN01_EN_V1R2

Datasheet. CozIR -A CO2 Sensor. Tel: +44 (0)

COMPACT FLAME CONTROLLER CFC 1000

COA-2010-F Electronic CO 2

Oxygen Sensing Solutions

Constant climate chambers

ExplorIR -W CO2 Sensor

MELA Sensortechnik GmbH

CDR-AL Room CO 2 Traffic Light Alarm Units and Sensors

Advantages / Characteristics

Dräger X-am 5600 Personal Monitor Multi-Gas Detection Device

GMH 285 / GMH 285-BNC

COMPACT FLAME CONTROLLER CFC 2000

Duct Humidity/Temp Sensor

HP 101A Series Humidity Temperature Probes INSTRUCTION MANUAL

Dräger Polytron 5700 IR Detection of flammable gases and vapours

ExplorIR -M CO2 Sensor

Improve Performance and Reduce Maintenance Costs. Model Q45D. Dissolved Oxygen Monitor...

AIRFLOW MEASUREMENT AND CONTROL PRODUCT CATALOG. Phone: 877-4GNTROL ( ) - Internet: GreenTrol.com. r1f

Connection. e. g. Pt100. reference limit. yellow Output I. Composition

CCD-Precision. Intelligent Laser-Optical Displacement Measurement. CCD System SENSORS & SYSTEMS. Authority in Displacement Measurement ILD 1800

hvgrometers Humidity Meters humidity meters hygrometers & therma-hygrometers what is a hygrometer? applications

Transcription:

Data Sheet 907021 Page 1/8 Hygro Transducer / Hygrothermal Transducer and CO 2 Measuring Probe for Climate Monitoring For measuring relative air humidity, temperature, and carbon dioxide concentration For building automation, storage rooms, and climate/ventilation control Available in the indoor, wall-mounted, and duct version Miniature rod version for OEM applications With current or voltage outputs as well as passive temperature output Hygro thermometer as tabletop/wall-mounted indicator These capacitive humidity transducers are conceived for the most common applications in heating, air conditioning, and ventilation technology. They distinguish themselves through their high measuring accuracy, excellent long-term stability, and good chemical resistance. In the case of CO 2 measuring probes, a proven infrared technology is used. The used NDIR procedure (non-dispersive infrared technology) utilizes a patented auto calibration function and eliminates all aging effects. The different combination possibilities between the process variables humidity (RH), temperature (T), and carbon dioxide (CO 2 ) as well as the optically pleasing and easily installable cases set new standards in HKL technology. The measuring probe in the indoor, wall-mounted, or rod version allow for a very broad field of application. For the respective process variables standardized current and voltage outputs are available. For temperature, passive resistance outputs can be delivered as an option. Measuring probes in the indoor version can also be equipped with an optional LCD display that shows the respective measured values in alteration. If, however, only a simple display of the process variables is needed then the battery-powered tabletop/wall-mounted indicator is the ideal solution. Applications can be found in all areas of ventilation technology and in building management. Examples are residential buildings, office buildings, public buildings, storage halls, and production halls. The humidity transducers of "version A" have performed particularly well in fields that have high demands on humidity measuring technology (e.g. greenhouses, swimming pools, or stables). In addition, the devices are also very suitable for outdoor use and in meteorology. Here, we recommend the radiation protection that is available in the accessories as it supplies the appropriate forced ventilation. Another available accessory is sensor coating. In many cases it enables improved or even permanent operation in atmospheres that are especially polluted.

Data Sheet 907021 Page 2/8 Technical data Humidity (RH) Humidity sensor Capacitive, can take condensation (sensor coating available as an option) Humidity measuring range 0 to 100 % RH Humidity working range 10 to 90 % RH: Tabletop/wall-mounted indicator, indoor version 10 to 95 % RH: Wall-mounted and duct version (version B) 0 to 100 % RH: Wall-mounted and duct version (version A); rod version Humidity accuracy at 20 C ±2 % RH: Indoor version and indicator in the humidity range between 40 to 60 % RH, wall-mounted and duct version (version A) in the humidity range between 0to90%RH (in the remaining range ±3 % RH) ±3 % RH: Indoor version with CO 2 in the humidity range between 30 to 70 % RH, wall-mounted and duct version (version B), rod version in the humidity range between 0 to 95 % RH (in the remaining range ±5 % RH) Temperature dependency ±0.05 % RH/ C (typical) Temperature (T) Temperature sensor Platinum-chip temperature sensor Pt1000 according to DIN EN 60751, tolerance class A (passively Pt100 as well) Temperature measuring range 0to50 C: Indoor version; wall-mounted and duct version (version B) -5 to +55 C: Tabletop/wall-mounted indicator -20 to +80 C: Wall-mounted and duct version (version A) -40 to +60 C: Rod version Accuracy temperature at 20 C ±0.25 C: Indoor version - voltage output ±0.4 C: Indoor version - current output ±0.7 C: Indoor version - current output (CO 2 ) ±0.3 C: Wall-mounted and duct version (version A); tabletop/wall-mounted indicator ±0.5 C: Wall-mounted and duct version (version B); rod version Carbon dioxide (CO 2 ) Measuring principle Non-dispersive infrared technology (NDIR) Sensor 2-beam infrared cells Measuring range 0 to 2000 ppm, 0 to 5000 ppm 0 to 10000 ppm (duct version only) Accuracy at +25 C and 1013 mbar ±(50 ppm +2 % from measured value) for range 0 to 2000 ppm ±(50 ppm +3 % from measured value) for range 0 to 5000 ppm ±(100 ppm +5 % from measured value) for range 0 to 10000 ppm Temperature dependency 2 ppm CO 2 / C (typical) Long-term stability 20 ppm/a (typical) Sampling rate Approx. 15 s Response time <195s

Data Sheet 907021 Page 3/8 Electrical data Voltage supply Self-supply Load resistance Output signals 2 DC 1.5 V Alkaline batteries: DC 15 to 35 V, AC 24 V ±20 %: DC 20 to 28 V: DC 4.5 to 30 V: DC 9to28V: Tabletop/wall-mounted indicator Humidity transducer with voltage output CO 2 measuring probe Humidity transducer with current output Only rod version with voltage output Only rod version with current output 5 to 10 ma with DC voltage supply, max. 20 ma with AC-voltage supply 1.5 ma for rod version 10 ma + output current, max. 0.5 A for 0.3 s with CO 2 measuring probe R L max. 500 ohm with current output Electromagnetic compatibility EN 61326-1 and EN 61326-2-3 Connection Screw terminals max. 1.5 mm 2 Connection diagram 4 to 20 ma, 0 to 1 V, 0 to 5 V, 0 to 10 V as well as Pt100, Pt1000 as passive temperature output (Basic types according to order details) See operating manual Case Case PC plastic Protection type IP20: indoor version, tabletop/wall-mounted indicator IP65: wall/duct/rod version Cable entry M16 1.5 (optionally available with plug connector) wall-mounted and duct version Ambient temperature -20 to +60 C: Indoor version and duct version (CO 2 ) -5 to +55 C: Indoor version with LCD display, tabletop/wall-mounted indicator, wall-mounted and duct version (version B) -40 to +60 C (measuring head 80 C): Wall-mounted and duct version (version A) -40 to +60 C: Rod version Storage temperature -25 to +60 C Weight Approx. 100 g Indoor version and tabletop/wall-mounted indicator Approx. 150 g Wall-mounted version Approx. 250 g Duct version Approx. 50 g Rod version

Data Sheet 907021 Page 4/8 Accessories Filter Humidity sensor checks Radiation protection Snap-in installation kit Sensor coating Plastic-grid membrane filter (standard): For small to normal contamination levels in the field of heating, air conditioning, and ventilation. Pore size 1 µm, t 10/90 approx. 15 s. Stainless steel sinter filter Most positive effects for high mechanical and thermic stresses. Unsuitable for high-humidity range. Pore size 10 µm, t 10/90 approx. 30 s. Plastic-grid power-line filter With high humidity, danger of condensation, or after rapidly changing humidity cycles. For average contamination level. Pore size 100 µm, t 10/90 approx. 7 s. PTFE filter: For high chemical resistance. Pore size 50 µm, t 10/90 approx 14 s. To test the accuracy of humidity transducers, humidity sensor checks can be used. The test procedure is described in DIN 50008, IEC publication 260, ISO /R 483-1966. The basic principle consists of an appropriate climate being produced above an aqueous, saturated salt solution. Humidity sensor checks with values of 33 % RH, 53 % RH, and 76 % RH are available directly from the factory. For outdoor use the measuring probes in the wall-mounted and rod version can be equipped with radiation protection. The radiation protection causes forced ventilation and largely prevents the heat up of the measuring head through solar radiation (and therefore also prevents incorrect measuring values). Depending on the type of installation one wants, two basic types are available: Basic type 907021/20: radiation protection "HA010501" with mounting brackets for wall mounting. Basic type 907021/40: radiation protection "HA010502" with clamping ring. The practical snap-in installation kit can be ordered as an option for the measuring probe. It essentially consists of a separate mounting plate and a plug connector on the device. This enables a fast and uncomplicated switch of transmitters. That feature is especially advantageous for frequent change interval, e.g. for replacement interval or for mobile applications. The sensor coating for the humidity sensor, which can also be ordered as an option, is an additional protective coating. It protects a humidity sensor even better against pollutants and, in many cases, allows a longer service life especially when dealing with polluted or aggressive atmospheres.

Data Sheet 907021 Page 5/8 Dimensions 80 35 34 50 80 Indoor version Basic type 907021/11 and 907021/80 As well as tabletop/wall-mounted indicator Basic type 907021/12 Ø 12 Wall-mounted versions Basic type 907021/20 Basic type 907021/21 Duct versions Basic type 907021/30 Basic type 907021/31 Basic type 907021/85 50 ±0.3 Ø 13 +0.1 64 ±0.3 Mounting flange for duct versions Ø 5 Rod version Basic type 907021/40 * Valid length for current output Radiation protection "HA010501" Drilling template for wall-mounted and duct versions

Data Sheet 907021 Page 6/8 Order details: hygro transducer / hygrothermal transducer (capacitive) for climate monitoring (1) Basic type 907021/11 Hygro transducer / hygrothermal transducer indoor version 907021/12 Hygro thermometer, tabletop/wall-mounted indicator 907021/20 Hygro transducer / hygrothermal transducer wall-mounted version (version A) 907021/21 Hygro transducer / hygrothermal transducer wall-mounted version (version B) 907021/30 Hygro transducer / hygrothermal transducer duct version (version A) 907021/31 Hygro transducer / hygrothermal transducer duct version (version B) 907021/40 Hygro transducer / hygrothermal transducer rod version (2) Version x x x x x x 1 Humidity (1-channel output) x x x x x x x 2 Humidity and temperature x x x x x x 3 Humidity and temperature (T passive) (3) Measuring ranges 1 x 33 10to95%RH; -5to+55 C x x x x x 34 0to100%RH; 0to50 C x x 10 0 to 100 % RH; -20 to +80 C x x x 14 0 to 100 % RH; -40 to +60 C x x 22 0 to 100 % RH; -30 to +70 C (4) Output signals x 000 No output, only display x x x x x x 005 4 to 20 ma / 4 to 20 ma x x x x x x 006 4 to 20 ma / temperature (T passive) Pt100, class A x x x x x x 007 4 to 20 ma / temperature (T passive) Pt1000, class A x x x 051 0to1V / 0to1V x x x 052 0 to 1 V / temperature (T passive) Pt100, class A x x x 053 0 to 1 V / temperature (T passive) Pt1000, class A x x 057 0to5V / 0to5V x x x x x 065 0to10V / 0to10V /(0to10V) x x x x x 066 0 to 10 V / temperature (T passive) Pt100, class A x x x x x 067 0 to 10 V / temperature (T passive) Pt1000, class A (5) Extra codes x x x x x x x 000 Without extra code x 793 Integrated LCD display (in case of several measured values) (not for T passive) x 794 Integrated LCD display (as in extra code 793), but temperature display in F (not for T passive) x x 764 Snap-in installation kit (mounting plate and plug connector), not for temperature (T passive) x x 796 Probe (short version for duct version, length 50 mm), not for CO 2 and T passive x 847 Longer connecting cable - length 3 m x 849 Longer connecting cable - length 10 m x x x 860 Sensor coating (1) (2) (3) (4) (5) Order code - - - /,... 2 Order example 907021/11-2 - 34-065 / 000 Note: Please note the humidity working range and the admissible ambient temperature (see "Technical data" in data sheet 907021). A second or a third output is only available in multichannel devices and is not always possible with all device combinations. 1 Please note humidity working area in Technical Data! 2 List extra codes in sequence, separated by commas.

Data Sheet 907021 Page 7/8 Order details: CO 2 measuring probe for climate monitoring (1) Basic type 907021/80 CO 2 measuring probe indoor version 907021/85 CO 2 measuring probe duct version (2) Version x 4 CO 2 x 5 CO 2 and temperature x x 6 CO 2 and temperature (T passive) x 7 CO 2, temperature and humidity (only for 0 to 10 V) (3) Measuring range x x 40 0 to 2000 ppm; 0 to 50 C; 0 to 100 % RH x x 41 0 to 5000 ppm; 0 to 50 C; 0 to 100 % RH x 42 0 to 10000 ppm; 0 to 50 C; 0 to 100 % RH (4) Output signals x x 005 4to20mA / 4to20mA x x 006 4 to 20 ma / temperature (T passive) Pt100, class A x x 007 4 to 20 ma / temperature (T passive) Pt1000, class A x x 065 0to10V / 0to10V /(0to10V) x x 066 0 to 10 V / temperature (T passive) Pt100, class A x x 067 0 to 10 V / temperature (T passive) Pt1000, class A (5) Extra codes x x 000 Without extra code x 793 Integrated LCD display (in case of several process values, alternating display) (not for T passive) x 794 Integrated LCD display (as in extra code 793), but temperature display in F (not for T passive) (1) (2) (3) (4) (5) Order code - - - /,... 1 Order example 907021/80-5 - 40-005 / 000 Note: Please note the humidity working range and the admissible ambient temperature (see "Technical data" in data sheet 907021). A second or a third output is only available in multichannel devices and is not always possible with all device combinations. 1 List extra codes in sequence, separated by commas.

Data Sheet 907021 Page 8/8 Stock versions Order code Part no. 907021/11-1-34-005/000 00436297 907021/11-2-34-005/000 00436298 907021/11-2-34-005/793 00441452 907021/12-2-33-000/000 00440647 907021/20-1-10-005/000 00388170 907021/20-2-10-005/000 00388171 907021/21-1-34-005/000 00388172 907021/21-2-34-005/000 00388173 907021/30-1-10-005/000 00388174 907021/30-2-10-005/000 00388175 907021/31-1-34-005/000 00388176 907021/31-2-34-005/000 00388177 907021/40-1-14-051/000 00388179 907021/40-2-14-051/000 00388180 907021/80-5-40-005/000 00578092 907021/80-5-40-005/793 00578093 907021/80-7-40-065/793 00578094 907021/85-4-40-005/000 00578095 907021/85-6-40-007/000 00578097 Accessories Article Part no. Plastic-grid membrane filter "HA010101" 00388181 Stainless steel sinter filter "HA010103" 00388183 Plastic-grid power-line filter "HA010106" 00389114 PTFE filter "HA010105" 00503575 Humidity sensor check 33 % RH 00332758 Humidity sensor check 53 % RH 00332754 Humidity sensor check 76 % RH 00332760 Radiation protection "HA010501" for basic type 907021/20 00388013 Radiation protection "HA010502" for basic type 907021/40 00573116