Leisure Line Stoves are to be used as supplemental heat only. Do not use this stove as a replacement for a furnace.

Similar documents
Leisure Line Power Vent Operations & Maintenance Manual And Safety Instructions

Leisure Line Power Vent Operations & Maintenance Manual And Safety Instructions

MX 200. MX-200 Technical Specifications FEATURES:

Installation, Operation and Maintenance Manual. 90,000 BTU & 105,000 BTU Stoker Coal Stoves

OWNER S MANUAL. DS Anthra-Max. Do Not Discard This Manual. High Efficiency Coal Stove. Models: XV14 XV15 XV16

MX 200. MX-200 Technical Specifications FEATURES:

Internet Version for Reference Only INDUCED DRAFT COMMERCIAL WATER HEATERS SUPPLEMENT INSTRUCTIONS TO PART #

Installation, Operation and Maintenance Manual. Koker, Koker Lite & Econo 90 Stoker Coal Stoves

CONVENIENCES FEATURES ADVANTAGES APPLICATIONS

HYBRID-FYRE FLUSH WOOD INSERTS

Specifications 3. Bladder 5. Chimney 12. Air Supply 12. Anti-Rollout Device and Ash Auger Tube 14. Timer 15

Indiana WX Oil Furnace Inspection Guide

Flush Wood Hybrid-Fyre Inserts

Flush Wood Hybrid-Fyre Inserts

B.C.S. Shop Heaters 26, 30 & 36 (36 shown)

THE GREEN ALTERNATIVE IN HOME HEATING

Revision B Printed Fall Elston Manufacturing HC Heater Owners Manual

OWNERS MANUAL MODEL DO110 & DO180 IS CERTIFIED TO: Unit Serial # Purchased From Company Address

WOOD STOVE SERVICE MANUAL

TABLE OF CONTENTS. Site preparation 2 Placement. 2 Chimney and stove pipe connections. 2

SAFETY NOTICE FEATURES PREPARATIONS INSTALLATION OPERATION

Hitzer Energy Master II Stoker Furnace Model 710 Owner s Manual Installation and Operation

INSTALLATION INSTRUCTIONS

Installation, Operation and Maintenance Manual. 90,000 BTU & 105,000 BTU Stoker Coal Stoves, Direct Vent

PLEASE KEEP THESE INSTRUCTIONS FOR FUTURE REFERENCE PELLET STOVE HP-0020S

Corn Flame Energy Corn Stove Model 3000

Burner Comparisons. Typical Competitor s Burner

Before selecting your stove, it is very important that you clearly identify what your needs are:

X-593 SOLID FUEL HEATING QUESTIONNAIRE

The Harman Magnum Stoker

LADERA. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES

SIERRA RADIANT HEAT MAJESTIC OAK VENTED GAS LOG KIT INSTALLATION AND OPERATING INSTRUCTIONS

ELITE SERIES Lo-Boy. AFUE - 83% Heating Input - 101,000 to 151,000 Btuh Nominal Add-on Cooling to 5 Ton. OIL FURNACES El0183b

Fire Chief Wood/Coal Burning Furnaces

BUILDING CODE GUIDELINE FOR MECHANICAL INSPECTIONS

Installation and Operating manual

K-2 & K-6 with 6 Inch Stack

Before selecting your stove, it is very important that you clearly identify what your needs are:

USER S INFORMATION MANUAL

Avalon Cast Iron Gas Stoves

Fully-automatic Gas tankless Water Heater USER'S MANUAL FOR MODEL EZ-101 ISO9001 certified

Columbia Boiler Company

INTRODUCTION TO HITZER STOVES INSTALLATION AND OPERATION

INSTALLATION INSTRUCTIONS

PUSHING THE LIMITS OF WHAT IS POSSIBLE

K-2 & K-6 Direct Vent

SOLID FUEL WARM AIR FURNACE

Technical Datasheet. Solo Innova Models 30 and 50. Benefits at a Glance: Solo Innova

Malm Fireplaces, Inc. 368 Yolanda Avenue, Santa Rosa, CA (707) Fax: (707)

FORCED DRAFT CONVERSION KIT #253

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. Alliance (EF3) TECHNICAL MANUAL

INSTALLATION & OPERATION MANUAL

SPECIFIC APPLIANCES, FIREPLACES AND SOLID FUEL-BURNING EQUIPMENT

CHIMNEY INSTALLATION. Technical Bulletin #1

Crown Boiler Company

INSTALLATION AND OPERATION INSTRUCTIONS FOR WOOD/OIL BURNING COMBINED FURNACES PSG/UH AND UH-CADDY

VENTING CLEARANCES. BBT NORTH AMERICA Bosch Group. Bosch Water Heating 340 Mad River Park, Waitsfield, VT TWH-V-26 page 1 of 6 rev 01/06

Direct Vent System Required

INSTALLATION & OPERATION MANUAL. Biomass Furnace/Stove Rev L, Patents Pending

INSTALLATION AND OPERATION MANUAL

SOLID FUEL WARM AIR FURNACE

Pellet Vent INSTALLATION INSTRUCTIONS

SERVICE FACTS WARNING M801-SF-1C. Gas Furnaces Upflow & Downflow Induced Draft 1 Stage Heat Models: DISCONNECT POWER BEFORE SERVICING M801P040AU24AA

The Accentra Pellet Stove

Installation, Operation and Service Manual

Owner s Manual for. PennStoker

SOLID FUEL WARM AIR FURNACE

Owner s Operation and Instruction Manual

OWNER S MANUAL MINI FREE-STANDING PELLET STOVE

VF/VG700 Jumbo. Construction Heater. Installation and Maintenance Manual

INSTALLATION AND SERVICE MANUAL

PELLET STOVES & INSERTS. PELLET STOVES & INSERTS

WARNING FIRE OR EXPLOSION HAZARD.

APPLICATION, INSTALLATION, AND MAINTENANCE MANUAL CA2XRT, CA3XRT, CA4XRT

ELECTRONIC FIREPLACE DAMPER

USER S INFORMATION MANUAL

ZC Kit AGP Pellet Insert

Shenandoah R65-E Coal Burning Heater Manual

INSTALLATION INSTRUCTIONS G60UH(X) Series

I2400 I3100 CLASSIC WOOD INSERTS ZONE HEAT FOR LOWER HEATING BILLS - I2400 A SIZE PERFECT FOR ANY ROOM - I3100 SPECIFICATIONS I2400 I3100

PARAFFIN/DIESEL HEATER

Econo Heater. Waste Oil Fired Heater. Installation, operation and service instructions EH v Manual. Manufactured by

OWNER S MANUAL. DS Greenhouse Blast GH450. Do Not Discard This Manual. High Efficiency Wood or Coal Green House Furnace. Model:

MONTECITO. Traditional. Fireplace Design Collection EPA WOOD BURNING FIREPLACES

APPUZO RANGE HOOD INSTALLATION

Operation Manual. An investment of a small amount of time to review this manual will ensure proper performance of your Coal-Trol Digital system.

1. GENERAL SAFETY RULES

SOLID FUEL WARM AIR FURNACE

Operating and Installation Instructions

ELECTRONIC FIREPLACE DAMPER

EVOLUTION PELLET STOVE

OWNER S MANUAL MX2 TM CONTROL EQUIPPED WOOD PELLET BURNING HEATER * INSTALLATION * OPERATION * SERVICE * PARTS *

MAXX OWNER S MANUAL F R E E S T A N D I N G P E L L E T S T O V E WARRANTY REGISTRATION enviro.com/warranty

INSTALLATION INSTRUCTIONS G50UH(X) Series

(Information about THERMAL dampers for gas-fired appliances available on request.) WARNING

INSTALLATION AND SERVICE MANUAL

SAVE THESE INSTRUCTIONS.

Draft Control D R A F T C O N T R O L G U I D E w w w. f i e l d c o n t r o l s. c o m August 2007

Model 1200G. SOLID FUEL WARM AIR FURNACE Owners Manual

SHERWOOD INDUSTRIES IS AN ENVIRONMENTALLY RESPONSIBLE COMPANY. THIS MANUAL IS PRINTED ON RECYCLED PAPER. OWNER S MANUAL

Transcription:

Leisure Line Stoves are to be used as supplemental heat only. Do not use this stove as a replacement for a furnace.

NOTES:

Actuation of your CO alarm indicates the presence of CO. Turn off your coal stove immediately and try to find & solve the problem. Open windows and doors to help move the fresh air throughout the house. Intertek Testing, Middleton, WI 53562 CONAM Inspection, Inc., Auburn, MA 01501 TESTED 8/96 (HYFIRE TESTED 12/96) TO ANSU/UL 1482, CSA B366-M1979 CHIMNEY TYPE: MINIMUM 6 INCH DIAMETER APPROVED LOW HEAT RESIDENTIAL TYPE ALL FUEL. CHIMNEY CONNECTOR: 6 INCH DIAMETER 24 GAUGE BLUE OR BLACK STEEL. INSTALL AT LEAST 18 INCHES FROM CEILING. SPECIAL METHODS ARE REQUIRED WHEN PASSING THROUGH A WALL OR CEILING. SEE INSTRUCTIONS AND BUILIDING CODES. SEE INSTRUCTION MANUAL FOR MOBILE HOME INSTALLATION. A B POCONO 30 21 PIONEER 31 18 HEARTH 27 18 ECONO 1* 30 18 ECONO SIDEWINDER 37 18 HYFIRE II* 34 24 USE APPROVED FLOOR PROTECTOR MUST HAVE 1.2 R VALUE CORNER INSTALLATION This does not include the POCONO or HYFIRE POCONO Clearance is 21 on the sides, HYFIRE clearance is 24 on the sides. 12 18 12 HOPPER 18 FRONT CONTACT YOUR LOCAL BUILDING OR FIRE OFFICIALS ABOUT RESTRICTIONS AND INSTALLATION INSPECTION IN YOUR AREA

Parts List 1 pc. 60lb. hopper w/blower 1 pc. Hopper lid 1 pc. Hopper gasket 1 pc. Feeder (burner, 70,000 BTU input) 1 pc. Firestop 2 pc. Thermostat Tools Needed 1-7/16 wrench or socket Connect marked wires on black box of the Thermostat and burner. (DO NOT use green marked wire). Hopper lid sweat is a sign of poor draft. Correct problem immediately!!!

Testing Results All Leisure Line Stoves are Tested To Underwriters Laboratories Standard #1482 By Conam Inspection, Auburn, MA 01501 Tested 8/96 to Ansi/UL 1482, CSA B366-M1979 Intertek Testing, Middleton, WI 53562 U.S. Environmental Protection Agency This heater is only for burning coal. Use of any solid fuel except coal ignition purposes is a violation of Federal Law. This product is Approved for Mobile Homes Proper clearances must be held. The stove must be secured to a non-combustible floor. A fresh air supply (outside) must be brought into the burner unit. Three (3) inch plastic pipe is recommended. Parts List 1 pc. 70lb. hopper 1 pc. Hopper lid 1 pc. Hopper gasket 1 pc. Feeder (burner, 90,000 BTU input) 2 pc. Thermostat Box 1 pc. A125/212 cfm blower 1 pc. Firestop 1 pc. Door Cover Tools Needed 1-3/8 Wrench 1-7/16 Wrench Prevent House Fires Install and Use Only in Accordance with the Manufacturer s Instructions and Local Building Codes. Always use a CO detector!! Safety First Place a CO detector on every floor of your house!!!

Connect marked wires on black box of the Thermostat and burner. (DO NOT use green marked wire). Hopper lid sweat is a sign of poor draft. Correct problem immediately!!!

Trouble Shooting Black Dust: Dirty coal, use caution when adding coal to the hopper Try oiled coal Turn off your fan when adding coal Parts List 1 pc. 110lb. hopper (Pioneer LE) 1 pc. 200lb. hopper (Pocono) 1 pc. Hopper lid 1 pc. Hopper gasket 1 pc. Feeder (burner, 90,000 BTU input) (for Pioneer) 1 pc. Feeder (burner, 110,000 BTU input) (for Pocono) 2 pc. Thermostat Box 1 pc. 265 cfm blower (Pioneer LE) 2 pc. 265 cfm blowers (Pocono) 1 pc. Firestop 1 pc. Door Cover Tools Needed 1-7/16 wrench or socket Sulfur Fumes: Make sure your chimney is clean Make sure all your pipes are clean Make sure the flue cap on your chimney is not too close to the top of the chimney and restricting draft. Make sure the clean-out door to the chimney is closed tight Make sure all door gaskets are intact and in good repair Make sure coal is not excessively wet Make sure the barometric damper is in good working order and not sticking open. Replace if needed. Make sure the stove is maintaining a draft Sweat on the hopper lid is a sign of poor draft Preheat chimney

Connect marked wires on black box of the Thermostat and burner. (DO NOT use green marked wire). Hopper lid sweat is a sign of poor draft. Correct problem immediately!!!

Assembly for Hyfire II A Carbon Monoxide detector must be used!!! Parts List 1 pc. 200lb. hopper 1 pc. Hopper lid 2 pc. Hopper gasket 1 pc. 180 BTU feeder (Hyfire II, 90,000 & 90,000 BTU input) 2 pc. Thermostat Box 2 pc. 265 cfm blowers (fans) 2 pc. Firestop Tools Needed 1-7/16 socket w/extension

The next step is to mount the black thermostat box. The black thermostat can be mounted on either side of the hopper. Holes provided on every hopper. Now install the glass. Place the self-adhesive gasket on both sides of the glass. Wrap the glass completely with the gasket. Take the 4 glass bolts and brackets out of the backside of the door. Install the glass and replace and snug the bolts. Connect marked wires on black box of the Thermostat and burner. (DO NOT use green marked wire). With your assembly finished, it is time to make all the final connections. Your thermostat should, at this point, be mounted. Make sure that your thermostat wire is connected to both the black box, as well as the unit that mounts on the wall. Hopper lid sweat is a sign of poor draft. Correct problem immediately!!!