UV Weather Resistance Test Chambers Introduction The UV Aging test chamber is used for testing light fastness and aging resistance non-metallic materials. NAE UV Climate test chamber uses 8 UV340 or UV313 lamps. Lamp quantity and illumination intensity is user selectable and adjusted with the manual Irradiance controlling meter. The meter operates like an eye as it can monitor the irradiance intensity and adjust the lamp power. This feature enhances the lamp life. Advantages of NAE UV Climate Test Chambers Longer lamp life Ease of operation with PLC touch screen controller Users can choose UVA-340 or UVB-313 lamps in the working room Production Standards GBT16422.3, GBT14522, GBT5170.9, GB16776. JIS D-0201,H-8502,H-8610,K-5400,Z-2371,ISO3768,3769,3770 ASTM G154, ASTM G151. Common Specifications Internal Materials SUS304 Stainless Steel Working Room Size 400 1140 390mm (D W H) Lamps UVA-340 or UVB-313 (8 pcs) Wave Length UVA (315 ~ 400nm), UVB(280 ~ 315nm) Lamp Power 40W / Each Lamp Life 1600 hours Test Time 0 ~ 999 hours (Adjustable) Center distance of lamp 70 mm Distance of specimen and lamp 50±3mm Irradiance 1.0 W/m2 (Adjustable) Effective Radiation Area 900 290mm
Irradiance blackboard +50 ~ +70 temperature Specimen Size 75 290mm Specimen Shelf Quantity 24 sets Temperature Range Rt +10 ~ +70 Temperature Fluctuation ±0.5 Temperature Uniformity ±1.0 Humidity Range 90%RH Water Consumption 8liters/ day Controller PLC controller Control system Running mode Sensor Fixor Program running PT100 Safety function Using environment Noise Water source standard Power Over-temperature protection Electric leakage protection Power phase protection Over-current protection Fuse protection Water shortage protection Ground protection Temperature +30 Humidity 85% RH Atmosphere 86 ~ 106 kpa 65 db Purified water 3.5 kw Standard Models Model Condensation Irradiance Control Water Spray Eye Se-001 Yes Yes Yes Yes Se-002 Yes Yes No Yes Se-003 No No No Yes
Xenon Lamp Weather Resistance Test Chambers Introduction Xenon Aging Test Chamber simulates full spectrum, users can test the durability of specimens in destructive spectrum environment. The NAE Aging Climate Test chamber includes water cooling as well as air cooling capabilities. The advantages of NAE Xenon Climate Test Chambers The using life of Xenon arc lamp is longer NAE Aging Test Chamber meet the international testing standards Production Standards GB/T2423.24-1995, GB/T16422.2, GB9344, GB/T1865-97 ISO105-B02, ISO105-B04, ISO105-B06, ISO105-B07, ISO105-B10, ISO11341,ISO12040, ISO29664, ISO4892-1/2, SAE J2412, SAE J2527, VW PV1306,VW PV3929, VW PV3930. AATCC TM16, AATCC TM169, ASTM C1257, ASTM C1442, ASTM C1519, ASTM C732,ASTM C734, ASTM C793, ASTM D1148, ASTM D1670, ASTM D2565, ASTM D3424,ASTM D3451, ASTM D4101, ASTM D4303, ASTM D4355, ASTM D4434, ASTM D4459, ASTM D4637, ASTM D4798, ASTM D4811, ASTM D5019, ASTM D5071, ASTM D5383,ASTM D5398, ASTM D5819, ASTM D6083, ASTM D6551, ASTM D6577, ASTM D6662,ASTM D6695, ASTM D6878, ASTM D7356, ASTM D750, ASTM D7869, ASTM D882, ASTM D904, ASTM D925, ASTM F1164, ASTM F1515, ASTM F2366, ASTM G151,ASTM G155, GM9125P, IEC-61345.
Common Specifications Internal Materials SUS304 Stainless Steel Temperature Range Rt+10 ~ +70 Temperature Fluctuation ±0.5 Temperature Uniformity ±1.0 Humidity Range 60% ~ 98%RH Rain Period 0 ~ 999 minutes(adjustable) Lamp Power 6 Kw Lamp Life 1200 hours Effective Irradiation Area 0.63 m2 Irradiation Distance 350 ~ 375mm Test Shelf Rotation Speed 1r/min (adjustable) Irradiation Wave Length (350 ~ 850nm) 850W/m2 (adjustable) Nozzle Water Pressure 78 ~ 127kPa Cooling Way Water Cooling Way Or Air Cooling Way Controller Control system Safety function Using environment Noise Water source standard Power supply standard Running mode Sensor Over-temperature protection Electric leakage protection Power phase protection Over-current protection Fuse protection Water shortage protection Ground protection Temperature Humidity PLC controller Fix or Program running PT100 +30 85% RH 86 ~ 106 kpa Atmosphere 65 db Purified water 120V/220V/240V/380V/415V, 50Hz/60Hz, Single or three phases Xe-190FL Standard Models Xe-767SL Model Working Room Size (D W H) Test Shelf Type Cooling Way Xe-190FL 500 760 500mm (190 Liters) Horizontal Shelf Air Cooling Xe-767SL 950 950 850mm (767 Liters) Rotation Shelf Water Cooling
Ozone Climatic Test Chambers Introduction Ozone is the major factor of rubber aging and cracking. NAE ozone aging test chambers can simulate the ozone environment. In order to test the aging quality of rubber users can adopt measures to prevent aging of rubber. The advantages of NAE Ozone aging test chambers NAE Ozone aging test chamber is used with high quality ozone generator The rotating specimen shelf is used with high quality stainless steel. The PLC touch screen controller is used to program the testing functions. NAE Ozone aging test chamber has Dynamic stretch and Static stretch test methods. Production Standards GB/T7762-2003 GB/T2951.21-2008, GB2423.22-87, GB2423.2-89, GB2424.1-89. IEC 60068-2-42/43, NSS, SS, ASS, CASS ASTM B-117,ASTM B-268 B-268,GB-T2423,GJB150 Common Specifications Internal materials S:S304 stainless steel External materials High quality cold rolled steel sheet Ozone concentration 0 pphm ~ 500 pphm (10 pphm ~ 1000 pphm option) Read resolution ±10% Air flow 0 ~ 5 Liter / hour Ozone generator Silent discharge ozone generator Temperature fluctuation ±0.5 Temperature uniformity ±2.0 eating rate 2.0~3.0 / min (no-load ) O ser action window Non-condensation observation window with light Test ole Stainless steel test hole, 1 set 50mm diameter Test s elf Rotation test shelf with stainless steel materials Rotation speed 1 ~ 10 rotations / min
Movement wheel Sealing material Heat insulating material Air supply system Control system Safety function Noise Power supply standard 4 sets movement wheels (fixation function) Silicon rubber sealing ring PU FOAM + Glass fiber cotton Axial flow fan + Fan centrifugal fan Circulation mode Forced air circulation PLC touch screen Controller controller PLC touch screen Running mode controller Program capacity 100 groups Section capacity 120 sections / group Sensor PT100 RS232 communication Connect Port port Over-temperature protection Electric leakage protection Power phase protection Over-current protection Fuse protection Water shortage protection Ground protection 65 db 120V/220V/240V/380V/415V, 50Hz/60Hz, Single or three phases Model CY-100L CY-225L CY-500L CY-1000L Standard Model Working room Temperature size(w D H) Range 450 450 500mm (100 Liters) 500 600 750mm (225 Liters) Rt + 10 ~ +60 800 700 900mm (500 Liters) 1000 1000 1000mm (1000 Liters) Air Source Air / Oxygen Standard Model