Honeywell Zephyr TM Analog Airflow Sensors. HAF Series High Accuracy ±50 SCCM to ±750 SCCM. Datasheet

Similar documents
Honeywell Zephyr Analog Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy ±50 SCCM to ±750 SCCM

Airflow Sensors Line Guide

Airflow Sensors Line Guide

Application Note Honeywell Zephyr Analog and Digital Airflow Sensors: HAF Series-High Accuracy, ±50 SCCM to ±750 SCCM

PRODUCT TRAINING MODULE: Honeywell Zephyr Airflow Sensors HAF Series High Accuracy

Honeywell Zephyr Digital Airflow Sensors: HAF Series High Accuracy 20 SLPM or 200 SLPM

Installation Instructions for the Honeywell Force Sensors FSA Series Compensated/Amplified

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi]

SSC Series Standard Accuracy Plastic Silicon Pressure Sensors ±2 % Total Error Band, Digital Output, SMT and DIP, 1 psi to 150 psi

Basic Board Mount Pressure Sensors. NBP Series Uncompensated/Unamplified 60 mbar to 10 bar [1 psi to 150 psi] Datasheet

Issue C. Installation Instructions for the Basic Amplified Board Mount Pressure Sensors, ABP Series

Miniature Low Pressure Flow-Through Sensors. 26PC Series, Compensated/Unamplified 1 psi to 100 psi. Datasheet

Miniature Low Pressure Sensors. 24PC Series, Uncompensated/Unamplified 0.5 psi to 250 psi. Datasheet

Basic Board Mount Pressure Sensors: NBP Series Uncompensated/Unamplified 1 Bar to 10 Bar [15 psi to 150 psi]

Installation Instructions for the

TruStability Board Mount Pressure Sensors

Installation Instructions for the MicroPressure Board Mount Pressure Sensors MPR Series Compact, High Accuracy, Compensated/Amplified

WARNING MISUSE OF DOCUMENTATION

FSS-SMT Series. Low Profile Force Sensor

19 mm Series Low Cost, Stainless Steel, Isolated Pressure Sensors

Selecting Honeywell Board Mount Pressure Sensors

Sensors in Ventilators

Force Sensors Line Guide

HIH-5030/5031 Series Low Voltage Humidity Sensors

Application Note Sensors and Flexible Heaters in Ventilator Applications

Issue C CAUTION

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6130/6131 Series with SPI Communication

Interfaces with many electrical components without buffering Thermally balanced integrated circuit for stable operation over a full temperature range

SX Series Silicon Pressure Sensors 0 psi to 1 psi to 0 psi to 150 psi

Magnetoresistive Sensor ICs. Nanopower Series. Datasheet

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6120/6121 Series

Application Note Sensors and Flexible Heaters in Anesthesia Machine Applications

Honeywell Zephyr TM Digital Airflow Sensors: HAF Series High Accuracy 10 SLPM, 15 SLPM, 20 SLPM, 50 SLPM, 100 SLPM, 200 SLPM or 300 SLPM.

Micropower Omnipolar Digital Hall-Effect Sensor ICs

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH9000 Series ±1.7 %RH Accuracy. Datasheet

FEATURES AND BENEFITS

Honeywell Zephyr TM Digital Airflow Sensors HAF Series High Accuracy: 10 SLPM, 15 SLPM, 20 SLPM, 50 SLPM, 100 SLPM, 200 SLPM, 300 SLPM

HIH-4030/31 Series Humidity Sensors

humidity sensors Line Guide FEATURES Honeywell HumidIcon HIH6120/6121 Series

The open-collector sinking output voltage is easily interfaced with a wide variety of electronic circuits.

Honeywell HumidIcon Digital Humidity/Temperature Sensors. HIH6100 Series ±4.0 %RH Accuracy. Datasheet

19 mm Series. Pressure Sensors Low-Cost, Stainless Steel, Isolated Sensors WARNING WARNING. Sensing and Control

HIH-4000 Series Humidity Sensors

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.

Supply voltage (Vcc) Vcc reference to ground V Supply current: off on. Vcc = 5 V, T = 25 C [77 F] Vcc = 5 V, T = 25 C [77 F

Potential Applications

HIH-4602-L Series Humidity Sensors

High Sensitivity Bipolar Latching Digital Hall-Effect Sensor ICs SS360NT/SS360ST/SS460S. Datasheet

Table 1. Absolute Maximum Ratings. Characteristic. Magnetic flux. ma maximum ±670 ±600 ±670 ± ± ±0.150 ± , , +0.

HIH-4010/4020/4021 Series Humidity Sensors

HIH-4602 A & C Series.

DESCRIPTION The HIH-4000 Series Humidity Sensors are designed specifically for high volume OEM (Original Equipment Manufacturer) users.


Model A-5. Low Range Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES

Installation Instructions for the 600 Series Optical Encoders

Quadrature Speed and Direction Sensors

Installation Instructions for the RTY Series Hall-Effect Rotary Position Sensor Issue 4

Model 424. Wing Union/Hammer Union Pressure Sensors DESCRIPTION POTENTIAL APPLICATIONS FEATURES

Omnipolar Digital Hall-effect Sensor ICs: SS351AT, SS451A, SS551AT

Model HL-Z. High Line Wet/Wet Differential Pressure Transducer DESCRIPTION FEATURES POTENTIAL APPLICATIONS

Model 3140 Series. Tension/Compression Pancake Load Cell DESCRIPTION FEATURES

Heavy Duty Pressure Transducers

Model Super TJE. Ultra Precision Pressure Transducer DESCRIPTION FEATURES

HPM Series. Issue B. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

MICRO SWITCH Miniature Industrial Limit Switch SZL-VL-S Series Issue 3. Datasheet

Installation Instructions for the LM Series MCU (Microcontroller Unit) LCD Hour Meter

Application Note Sensors and Flexible Heaters in Sleep Apnea Machines

MICRO SWITCH NT Series

HPM Series. Issue C. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

MICRO SWITCH NT Series

Model SC3004. Transducer Display and Signal Conditioning Unit DESCRIPTION. Fourteen channel chassis FEATURES

GMS-10 RVS Series. Oxygen Sensors Accurate oxygen measurement WARNING WARNING DESCRIPTION TYPICAL APPLICATIONS FEATURES MISUSE OF DOCUMENTATION

Installation Instructions for the

HFX Fiber Optic Component 50 Mbps, 650 nm LED

Board Mount Pressure Sensors Line Guide

Magnetoresistive Sensor ICs 2SS52M Series Issue 2. Datasheet. Sensing and Productivity Solutions

Honeywell HumidIcon Digital Humidity/Temperature Sensors: HIH6000 Series ±4.5 %RH Accuracy

Non-Contact Safety Switches FF6 Series Issue 4. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

AMR 4-Pin Quadrature Sensor Integrated Circuit

Issue B. Bipolar Hall-Effect Digital Position Sensor ICs: SS41, SS41-L, SS41-T2, SS41-T3, SS41-S, SS41-SP. Sensing and Internet of Things

MICRO SWITCH V15W Series Watertight Miniature Switches

Linear Current Sensors

V-Basic Standard V15 Series

MS4525DO SPECIFICATIONS FEATURES APPLICATIONS

Intrinsically Safe Transmitters, Option Code 2n

HPM Series. Issue D. Particle Sensor FEATURES DESCRIPTION POTENTIAL INDUSTRIAL APPLICATIONS VALUE TO CUSTOMERS DIFFERENTIATION

Issue 4. Bipolar Hall-Effect Digital Position Sensor ICs: SS40F, SS40AF. Sensing and Internet of Things. Datasheet

MICRO SWITCH BAF/DTF Series

MS4525 SPECIFICATIONS

HOA6480 Series Barcode Sensor Infrared Products

MICRO SWITCH Watertight Miniature Basic Switches. V15W Series. Datasheet

Sensor ICs: SS360NT, SS360ST, SS360ST-10K, SS460S, SS460S-T2, SS460S-LP

Sensors and Switches in Commercial Traction Elevators

MICRO SWITCH Key Actuated Safety Switches GKN Series Issue 3. Datasheet FEATURES POTENTIAL APPLICATIONS DESCRIPTION DIFFERENTIATION PORTFOLIO

Configurable Pressure Transducer Model FP Issue 1. Sensing and Internet of Things. Datasheet FEATURES DESCRIPTION DIFFERENTIATION

MICRO SWITCH GLL Series

FR/SR Series. Full Sized, Sealed Rocker Switches SR SERIES FR SERIES DESCRIPTION FR SERIES SR SERIES FEATURES FR SERIES SR SERIES

MSP100 Pressure Transducer

Heavy Duty Pressure Transducers Line Guide

Transcription:

Honeywell Zephyr TM Analog Airflow Sensors HAF Series High Accuracy ±50 SCCM to ±750 SCCM Datasheet

Honeywell Zephyr TM Analog Airflow Sensors HAF Series - High Accuracy Honeywell Zephyr HAF Series sensors provide an analog interface for reading airflow over specified full-scale flow and compensated temperature ranges. The thermally isolated heater and temperature sensing elements help these sensors provide a fast response to air or gas flow. Zephyr sensors are designed to measure mass flow of air and other non-corrosive gases. Standard flow ranges are available at ±50, ±100, ±200, ±400 or ±750 SCCM. Custom flow ranges are also available. The sensors are fully calibrated and temperature compensated with an onboard Application Specific Integrated Circuit (ASIC). The HAF Series is compensated over the temperature range of 0 C to 50 C [32 F to 122 F] and operates across a temperature range of -20 C to 70 C [-4 F to 158 F]. The state-of-the-art ASIC-based compensation provides analog outputs with a response time of 1 ms. These sensors operate on the heat transfer principle to measure mass airflow. They consist of a microbridge Microelectronic and Microelectromechanical System (MEMS) with temperature-sensitive resistors deposited with thin films of platinum and silicon nitride. The MEMS sensing die is located in a precise and carefully designed airflow channel to provide repeatable response to flow. Zephyr sensors provide the customer with enhanced reliability, high accuracy, repeatable measurements and the ability to customize sensor options to meet many specific application needs. The combination of rugged housings with a stable substrate makes these products extremely robust. They are designed and manufactured according to ISO 9001 standards What makes our sensors better? Fast response time Wide range of airflows Customizable flow ranges and configurable package styles Linear output High stability Low pressure drop TIGHT TOTAL ERROR BAND fast response TIME Wide Range of Airflows 2 sensing.honeywell.com

Features and Benefits FAST RESPONSE TIME* Allows a customer s application to respond quickly to airflow change, important in critical medical (e.g., anesthesia) and industrial (e.g., fume hood) applications. Wide range of airflows* Zephyr measures mass flow at standard flow ranges of ±50, ±100 ±200, ±400 or ±750 SCCM, or custom flow ranges, increasing the options for integrating the sensor into the application. Customizable flow ranges and configurable package styles* Meet specific end-user needs. FULL CALIBRATION AND TEMPERATURE COMPENSATION Typically allow customer to remove additional components associated with signal conditioning from the PCB, reducing PCB size as well as costs often associated with those components (e.g., acquisition, inventory, assembly). LINEAR OUTPUT* Provides more intuitive sensor signal than the raw output of basic airflow sensors, which can help reduce production costs, design, and implementation time. Low pressure drop* Typically improves patient comfort in medical applications, and reduces noise and system wear on other components such as motors and pumps. 0.049 %FS resolution Increases ability to sense small airflow changes, allowing customers to more precisely control their application. Low 3.3 Vdc operating voltage option and low power consumption Allow for use in battery-driven and other portable applications. Small size Occupies less space on PCB, allowing easier fit and potentially reducing production costs; PCB size may also be reduced for easier fit into space-constrained applications. RoHS-compliant materials Meet Directive 2002/95/EC. *Competitive Differentiator sensing.honeywell.com 3

Potential Applications MEDICAl Anesthesia Delivery machines Ventricular Assist Devices (Heart Pumps) Nebulizers Oxygen concentrators Patient monitoring systems (respiratory monitoring) Sleep apnea machines Spirometers Ventilators LAPAROSCOPY INDUSTRIAL AIR-TO-FUEL RATIO FUEL CELLS GAS LEAK DETECTION VAV SYSTEM ON HVAC SYSTEMS GAS METERS HVAC FILTERS 4 sensing.honeywell.com

±50 SCCM to ±750 SCCM Table 1. Absolute Maximum Ratings 1 Characteristic Parameter Supply voltage -0.3 Vdc to 6.0 Vdc Voltage on I/O output pin -0.3 Vdc to Vsupply Storage temperature range -40 C to 125 C [-40 F to 257 F] Maximum flow change 5.0 SLPM/s Maximum common mode pressure 25 psi at 25 C [77 F] Maximum flow 10 SLPM 1 Absolute maximum ratings are the extreme limits that the device will withstand without damage to the device. However, the electrical and mechanical characteristics are not guaranteed as the maximum limits (above recommended operating conditions) are approached, nor will the device necessarily operate at absolute maximum ratings. CAUTION IMPROPER USE Do not use these products to sense liquid flow Failure to comply with these instructions may result in product damage. CAUTION PRODUCT DAMAGE Do not disassemble these products. Failure to comply with these instructions may result in product damage. Table 2. Operating Specifications Characteristic Parameter Note Supply voltage 3.3 Vdc 5.0 Vdc Power: 3.3 Vdc 5.0 Vdc 3.3 Vdc ±10% 5.0 Vdc ±10% 40 mw max. 65 mw max. Compensated temperature range 0 C to 50 C [32 F to 122 F] 2 Operating temperature range -20 C to 70 C [-4 F to 158 F] Accuracy See Table 3. 3, 4 Total Error Band (TEB) See Table 3. 4, 5 Null accuracy ±0.1 %FSS 4, 6 Response time 1 ms typ. 7 Resolution 12 bit Warm-up time 15 ms 8 Calibration media gaseous nitrogen 9 Null stability ±0.06 %FSS max. deviation from null output after 1000 hrs at 25 C Reverse polarity protection no 1 Maximum power: Is measured under the conditions of the highest supply voltage, Vsupply + 10%, 70 C, full scale flow and with the minimum load specified for that supply voltage. 2 Custom and extended compensated temperature ranges are possible. Contact Honeywell for details. 3 Accuracy: The maximum deviation from the nominal output over the compensated flow range at a reference temperature of 25 C. Errors include offset, span, non-linearity, hysteresis and non-repeatability. 4 Full Scale Span (FSS): The algebraic difference between the output at the forward Full Scale (FS) flow and the output at the reverse FS flow. Forward flow is defined as flow from P1 to P2 as shown in Figure 9. The references to mass flow (SCCM) refer to gas flows at the standard conditions of 0 C and atmospheric pressure 760 (101.3 kpa). 5 Total Error Band: The maximum deviation in output from the ideal transfer function over the entire compensated temperature and flow range. Includes all errors due to offset, full scale span, flow hysteresis, flow repeatability, thermal effect on offset, thermal effect on span and thermal hysteresis. 6 Null accuracy: The maximum deviation in output at 0 SCCM from the ideal transfer function over the compensated temperature range. This includes offset errors, thermal airflow hysteresis and repeatability errors. 7 Response time: The time to electrically respond to any mass flow change at the microbridge airflow transducer (response time of the transducer may be affected by the pneumatic interface). 8 Warm-up time: The time to the first valid flow measurement after power is applied. 9 Default calibration media is dry nitrogen gas. Please contact Honeywell for other calibration options. 1 sensing.honeywell.com 5

Honeywell Zephyr TM Analog Airflow Sensors HAF Series High Accuracy Table 3. Bidirectional Forward Flow Optimization Accuracy Error Band Error (%FSS) See table below for null accuracy. Total Error Band Error (%FSS) See table below for null accuracy. Sensor Range (SCCM) Airflow (SCCM) Airflow (SCCM) ±50 ±100 ±200 1 ±400 ±750 Applied Flow (SCCM) Error (%FSS) Applied Flow (SCCM) Error (%FSS) -50 to -14.3 ±7% reading -50 to -11.3 ±9% reading -14.3 to 0 ±1-11.1 to 0 ±1 00 ±0.32 00 ±0.32 0 to 20 ±1 0 to 11.1 ±1 20 to 50 ±5% reading 11.1 to 50 ±9% reading -100 to -11.1 ±9% reading -100 to -8.3 ±12% reading -11.1 to 0 ±0.5-8.3 to 0 ±0.5 00 ±0.16 00 ±0.16 0 to 16.7 ±0.5 0 to 16.7 ±0.5 16.7 to 100 ±6% reading 16.7 to 100 ±6% reading -200 to -6.7 ±15% reading -200 to -6.7 ±15% reading -6.7 to -0 ±0.25-6.7 to -0 ±0.25 00 ±0.1 00 ±0.1 0 to 40 ±0.25 0 to 22.2 ±0.25 40 to 200 ±2.5% reading 22.2 to 200 ±4.5% reading -400 to -32 ±10% reading -400 to -32 ±12% reading -32 to -0 ±0.4-32 to -0 ±0.45 00 ±0.1 00 ±0.1 0 to 80 ±0.4 0 to 60 ±0.45 80 to 400 ±4.0% reading 60 to 400 ±6% reading -750 to -25 ±15% reading -750 to -25 ±15% reading -25 to -0 ±0.25-25 to -0 ±0.25 00 ±0.1 00 ±0.1 0 to 37.5 ±0.25 0 to 37.5 ±0.25 37.5 to 750 ±10% reading 37.5 to 750 ±10% reading 1 The short port sensors are only specified down to -100 SCCM. 6 sensing.honeywell.com

±50 SCCM to ±750 SCCM Table 4. Suggested Load Characteristic Minimum suggested resistance: 3.3 Vdc 5.0 Vdc Maximum suggested capacitance: 3.3 Vdc 5.0 Vdc Parameter 3.3 kohm 5 kohm 10 nf 10 nf CAUTION LARGE PARTICULATE DAMAGE Use a 5-micron filter upstream of the sensor to keep media flow through the sensor free of condensing moisture and particulates. Large, high-velocity particles or conductive particles may damage the sensing element. Failure to comply with these insturctions may result in product damage. Table 5. Environmental Characteristics Table 6. Wetted Materials Characteristic Parameter Characteristic Parameter Humidity 0% to 95% RH, non-condensing Covers high temperature polymer Shock 100 g, 11 ms Substrate PCB Vibration 15 g at 20 Hz to 2000 Hz Adhesives epoxy ESD Class 3B per MIL-STD 883G Electronic components Compliance silicon, gold RoHS, WEEE Table 7. Recommended Mounting and Implementation Characteristic Mounting screw: size torque Silicon tubing for long port style O-ring: for short port style for long port style Filter Parameter 5-40 0,68 N m [6 in-lb] 70 durometer; size 0.125 in inside diameter, 0.250 in outside diameter silicone tubing AS568A, Size 7, Silicone, Shore A 70 AS568A, Size 10, Silicone, Shore A 70 5-micron filter upstream of the sensor Figure 2. Nominal Analog Output 120.00% Analog Output (%Vsupply) 100.00% 80.00% 60.00% 40.00% 20.00% 0.00% -150.00% -100.00% -50.00% 0.00% 50.00% 100.00% 150.00% Flow (%FS) sensing.honeywell.com 7

Honeywell Zephyr TM Analog Airflow Sensors HAF Series High Accuracy Figure 3. Ideal Transfer Function V =V o s 0.5 +0.4 F F ( ) FFS V o/vs-0.5 F= A 0.4 A FS Where: V O = output voltage of the device V S = supply voltage measured at the device F A = flow applied across the device F FS = full scale flow specified for the device Figure 4. Nomenclature and Order Guide For example, a HAFBLF0200CAAX5 part number defines a Honeywell Zephyr TM Analog Airflow Sensor, bidirectional forward flow optimized, long port, fastener mount, 200 SCCM, analog output, 10% to 90% transfer function, 5.0 Vdc supply voltage. HAF B L F 0200 C A A X 5 Product Series HAF Series High Accuracy B Airflow Sensor S Flow Direction Bidirectional forward flow optimized Bidirectional symmetric Port Style L Long port 1 S Short port F S Housing Style Fastener mount Snap mount 1 Flow Range 2 50 long port 0050 style only 100 long port 0100 style only 200 long or 0200 short port 400 long port 0400 style only 750 long port 0750 style only C Unit SCCM Output Format A Analog A Transfer Function 10% to 90% of Full Scale Output (FSO) Reserved for Future Use X XXXXX 3 5 Supply Voltage 3.3 Vdc 5.0 Vdc 1 The Long Port Port Style with the Snap Mount Housing Style is not a valid configuration. 2 The 200 SCCM Flow Range is available in the Long and Short Port Styles. Apart from the general configuration required, other customer-specific requirements are also possible. Please contact Honeywell. Figure 5. All Available Standard Configurations LF: Long port, fastener mount SF: Short port, fastener mount SS: Short port, snap mount 8 sensing.honeywell.com

±50 SCCM to ±750 SCCM Figure 6. Wave Solder Profile Figure 7. Long Port Style Flow vs Pressure N Pressure Drop (inh 2 O) 0.12 0.06 0-0.06 300 250 200 150 100 50-0.12-750 -600-450 -300-150 0 150 300 450 600 750 Flow (SCCM) Max. temp. = 243 C Max. temp. = 205 C 0 0 20 40 60 80 100 Time (s) Housing temp. (top of device) Pin temp. (bottom of device) Flow (SCCM) Typical Pressure Drop mbar inh 2 O Pa -750-0.2517-0.1011-25.17-550 -0.1499-0.0602-14.99-400 -0.0891-0.0358-8.91-300 -0.0578-0.0232-5.78-200 -0.0321-0.0129-3.21-100 -0.0114-0.0046-1.14-50 -0.0035-0.0014-0.35-20 -0.0007-0.0003-0.07 0 0.0000 0.0000 0.0000 20 0.0007 0.0003 0.07 50 0.0035 0.0014 0.35 100 0.0014 0.0046 0.14 200 0.0321 0.0129 3.21 300 0.0578 0.0232 5.78 400 0.0891 0.0358 8.91 550 0.1499 0.0602 14.99 750 0.2517 0.1011 25.17 Figure 8. Short Port Style Flow vs Pressure N Pressure Drop (inh 2 O) 0.6 0.4 0.2 0-0.2-0.4-0.6-200 -150-100 -50 0 50 100 150 Flow (SCCM) 200 Flow (SCCM) Typical Pressure Drop mbar inh 2 O Pa -200-1.1707-0.470-117.07-150 -0.7074-0.284-70.74-100 -0.3562-0.143-35.62-50 -0.1120-0.045-11.20 0 0.0000 0.000 0.0000 50 0.1196 0.048 11.96 100 0.3462 0.139 34.62 150 0.7149 0.287 71.49 200 1.2589 0.452 125.89 sensing.honeywell.com 9

Honeywell Zephyr TM Analog Airflow Sensors HAF Series High Accuracy Figure 9. Mounting Dimensions (For reference only: mm [in].) LF: Long port, fastener mount MODEL NUMBER LOT CODE Honeywell Zephyr HAFBLFXXXXXXXXX 0x123456789 Mounting Footprint 3,0 [0.12] 2,00 TYP. [0.079] 1,00 [0.04] 3,50 [0.14] 18,00 [0.71] 36,00 [1.42] 10,3 [0.40] 10,00 [0.39] 6,50 [0.26] 2X DIA. 5,35 [0.21] 4X DIA. 0,812 [0.032] 2X DIA. 3,40 [0.134] 19,90 [0.78] 2X DIA. 3,40 [0.13] 36,00 [1.42] 6,35 [0.25] 12,70 [0.50] 28,80 [1.13] AIRFLOW DIRECTION, PORT SIDE SF: Short port, fastener mount MODEL NUMBER LOT CODE Honeywell Zephyr HAFBSFXXXXXXXXX 0x123456789 3,0 [0.12] 2,00 TYP. [0.079] 1 2 3 4 1,00 [0.04] 3,50 [0.14] Mounting Footprint 18,00 [0.71] 36,00 [1.42] 10,3 [0.40] 2,50 [0.10] 2X DIA. 4,00 [0.16] 4X DIA. 0,812 [0.032] 6,50 [0.26] 19,90 [0.78] 2X DIA. 3,40 [0.134] 2X DIA. 3,40 [0.13] 36,00 [1.42] 6,35 [0.25] 12,70 [0.50] 28,80 [1.13] AIRFLOW DIRECTION, PORT SIDE 10 sensing.honeywell.com

±50 SCCM to ±750 SCCM Figure 9. Mounting Dimensions (For reference only: mm [in], continued.) SS: Short port, snap mount 22,00 [0.87] DIA. 2,30 [0.09] MODEL NUMBER LOT CODE Honeywell Zephyr HAFBSSXXXXXXXXX 0x123456789 3,3 [0.13] 26,00 [1.02] 2,00 TYP. [0.079] 1,00 [0.04] 4,80 [0.19] 1,80 [0.071] 10,3 [0.40] 6,50 [0.26] 10,40 [0.41] 4,60 [0.18] 3,00 [0.12] 12,8 [0.50] 4X DIA. 0,812 [0.032] Mounting Footprint 22,0 [0.866] 2X DIA. 2,2 [ HOLES FOR 3 [0 4,00 [0.15 2X [ 2,50 [0.10] 26,00 [1.024] 19,90 [0.78] 6,35 [0.25] 12,70 [0.50] 28,80 [1.13] 10 Table 8. Pinout AIRFLOW DIRECTION, PORT SIDE Pin 1 Pin 2 Pin 3 Pin 4 Vout Vsupply grground NC sensing.honeywell.com 11

ADDITIONAL INFORMATION The following associated literature is available at sensing.honeywell.com: Product line guide Product part listing/nomenclature tree Product range guide Technical Information: Gas Media Compatibility and Correction Factors Installation Instructions Application specific information WARNING PERSONAL INJURY DO NOT USE these products as safety or emergency stop devices or in any other application where failure of the product could result in personal injury. Failure to comply with these instructions could result in death or serious injury. WARNING MISUSE OF DOCUMENTATION The information presented in this product sheet is for reference only. Do not use this document as a product installation guide. Complete installation, operation, and maintenance information is provided in the instructions supplied with each product. Failure to comply with these instructions could result in death or serious injury. WARRANTY/REMEDY Find out more Honeywell serves its customers through a worldwide network of sales offices, representatives and distributors. For application assistance, current specifications, pricing or name of the nearest Authorized Distributor, contact your local sales office. To learn more about Honeywell s sensing and control products, call +1-815-235-6847 or 1-800-537-6945, visit sensing.honeywell.com, or e-mail inquiries to info.sc@honeywell.com Honeywell warrants goods of its manufacture as being free of defective materials and faulty workmanship. Honeywell s standard product warranty applies unless agreed to otherwise by Honeywell in writing; please refer to your order acknowledgement or consult your local sales office for specific warranty details. If warranted goods are returned to Honeywell during the period of coverage, Honeywell will repair or replace, at its option, without charge those items it finds defective. The foregoing is buyer s sole remedy and is in lieu of all other warranties, expressed or implied, including those of merchantability and fitness for a particular purpose. In no event shall Honeywell be liable for consequential, special, or indirect damages. While we provide application assistance personally, through our literature and the Honeywell website, it is up to the customer to determine the suitability of the product in the application. Specifications may change without notice. The information we supply is believed to be accurate and reliable as of this issue; however, we assume no responsibility for its use. Sensing and Control Honeywell 1985 Douglas Drive North Golden Valley, MN 55422 honeywell.com 32308685-A-EN IL50 June 2015 2015 Honeywell International Inc. All rights reserved.