C7031D,G,J C7041B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors

Similar documents
T7079A,B Solid State Remote Temperature Controllers

The T6140A,B Remote Bulb Temperature Controller

C7232A,B Sensor and Controller CARBON DIOXIDE SENSOR

Commercial/Industrial Combustion Control Level Three Announcement

L8005A,B; LS8005A,C,D Electronic Pool and Spa Controllers

T4031A,B,P; T6031A,B Refrigeration Temperature Controllers

C554A Cadmium Sulfide Flame Detector

CR7075 Two-Stage Lighting Controller

T6984F,G Electronic Floating Control Thermostats

C6097A,B Pressure Switches

Solid Core and Split Core 4-20 ma Output Current Sensors CTS-20; CTP-20

T4398A,B High Performance Electric Heat Thermostats

T4098A,B Deluxe Electric Heat Thermostats

T7984 A,B,C Electronic Modulating Control Thermostats

Solid Core and Split Core 0-5, 0-10 Vdc Output Current Sensors CTS-05,10; CTP-05,-10

F150E Media Air Cleaner

Solid Core and Split Core Fixed Current Status Switches CSS-O,C; CSP-O,C -F (FIXED) SERIES

C7007A, C7008A, C7009A Flame Rod Holder & Flame Rod Assemblies

F25F Media Air Cleaner

L8151A Triple Aquastat Relay

C7232A,B Sensor and Controller

H1008A,D Automatic Humidity Controls

T6984 A,D,E Electronic Floating Control Thermostats

F200E Charged-Media Air Cleaner

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

T8411R Electronic Heat Pump Thermostat

C7004B Flame Rod Holder

TG509, TG510, TG511, TG512 Versaguard Universal Thermostat Guards

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats XE88/XE100 SERIES

Sensors Product Overview. Reliable And Accurate Honeywell Sensors

Instructions For A and Flame Simulators

EL7611A/EL7612A Ultrasonic Occupancy Sensors and EL7621A Power Pack PRODUCT DATA

RA889A Switching Relay

T834C Heating-Cooling Thermostat

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

T8011R Programmable Heat Pump Thermostat

M6063A Compact Rotary Mixing Valve Actuator

HE365A,B Powered Flow-Through Humidifier

R7824, R7847, R7848, R7849, R7851, R7852, R7861, R7886 Amplifiers for 7800 SERIES and R7140 Relay Modules

L Honeywell. L4068 has spst switch; L6068 has spdt switch. L4068A,C,E,F have adjustable FAN OFF and differential settings.

T8524 Deluxe Electronic Thermostat

HE225A,B and HE265A,B Bypass Flow-Through Humidifier

Sensor Selection Guide. Sensing for Building Applications

AQ475A Aquatrol Outdoor Temperature Compensator for Boilers

HE220, HE260 Humidifier Installation Kit

T874 Multistage Thermostat and Q674 Subbase

C7005A,B Gas Pilot and Flame Rod Assemblies

P7810A-D Pressuretrol Controller

T8190A/191108AJ Heating or Cooling Thermostat/Wallplate; T8190A/Q682B Heating/Cooling Thermostat/Subbase

IS Series Pressure Sensing Switches

T7047C,G,H Remote Space Sensors

Deluxe Programmable Thermostats

R7824, R7847, R7848, R7849, R7851,R7861, R7886 Amplifiers for 7800 SERIES Relay Modules

T8602C Chronotherm IV Deluxe Programmable Thermostats

Q382A,B Pilot Burners

Deluxe Programmable Heat Pump Thermostat T8611M

T8600D Chronotherm IV Deluxe Programmable Thermostats

AQ250 Series Hydronic Control Panels

HE120, HE160 Humidifier Installation Kit

T8624D Chronotherm IV Deluxe Programmable Multistage Thermostats

T8611M Deluxe Programmable Heat Pump Thermostats

D896 Automatic Vent Damper

RA890G Protectorelay Primary Control

T6572A, T6573A,B, T6992A,B, T6993B Digital Fan-Coil Thermostats

T7200D,E Series 2000 Commercial Microelectronic Thermostats

L4188A,B; L4189A,B; L6188A-C; L6189A-C Aquastat Controllers

HE360 Humidifier Installation Kit

HE420A Steam Power Humidifier

CT500 Electronic Thermostat

RA889A Switching Relay

T8112 Programmable Thermostat

AQ255 and AQ257 Series Expansion Zoning Panels

T8611G Chronotherm Deluxe Zoning Heat Pump Thermostat

T4398A,B Precision Electric Heating Thermostat

C7915A Infrared Flame Detector

HR150B, HR200B Perfect Window Fresh Air Ventilation Systems

T7300F Series 2000 Commercial Microelectronic Conventional or Heat Pump Thermostat

Electronic Thermostat

Q7300H Series 2000 Commercial Thermostat Subbases

SLATE. Rectification Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001V1031

YP7999A1000 ControLinks Fuel Air Ratio Control Panel

SLATE. UV Ampli-Check Flame Amplifier INSTALLATION INSTRUCTIONS R8001S1071

T7351 Programmable Thermostat FOR CONVENTIONAL/HEAT PUMP SYSTEMS

VisionPRO 8000 with Wi-Fi

HE365A,B Powered Flow-Through Humidifier with

7800 SERIES 22-Terminal Universal Subbase

SLATE. Sub-Base Module INSTALLATION INSTRUCTIONS R8001S9001

HE360 Powered Flow-Through Humidifier

CR Series Command Relays

Honeywell CT8602 PROGRAMMABLE THERMOSTAT

HE420A,B and HE460A,B Steam Power Humidifiers OWNER S GUIDE

USER INSTRUCTIONS FOR FLANGE IMMERSION HEATERS USED IN HAZARDOUS LOCATIONS

SIL3. C7961E,F Dynamic Self-Check Ultraviolet Flame Detector. Capable APPLICATION FEATURES PRODUCT DATA. Contents

Installation Instructions

Installation Instructions

F59A Console 3-Speed Electronic Air Cleaner

Aquastats. Aquatrol Indoor/Outdoor Control. Automatic Changeover Switch 16/05/08

Installation Instructions Part No , Part No Part No

HE365A,B Powered Flow-ThroughHumidifier with

HE360A,B Powered Flow-Through Humidifier

Transcription:

C703D,G,J C70B,C,D,F,J,K,P,R Series 2000 Electronic Temperature Sensors PRODUCT DATA C703D, C70D C70B,C C70R C703G, C70F C70P FEATURES C703D, C70D for immersion mounting sense water temperature. C703G, C70F sense outdoor air temperature and are weatherproof for outdoor use (knockouts allow for /2 in. conduit connection). C703J, C70J,R sense average duct air temperature. C70B,C sense duct air temperature. C70K with strap-on mounting senses water temperature. C70P senses air temperature. Solid state components not affected by dust or dirt. C703J, C70J C70K APPLICATION The Series 2000 C703, C70 Electronic Temperature Sensors are designed for use with electronic controllers in domestic or commercial heating and cooling systems. Contents Application... Features... Specifications... 2 Ordering Information... 2 Installation... 5 Wiring... 8 Operation and Checkout... 8 63-2590 2

SPECIFICATIONS Models: Use Series 2000 C703, C70 Temperature Sensors with Excel 0, 5, 80, 00, and 500 controllers. See Tables and 2 for specifications. Series 2000 C703D,G,J Sensors are compatible with various Honeywell legacy controllers. The C703G20 is compatible with the T7350 Commercial Thermostat. Dimensions: See Fig. 3 through 8. Element Operating Range: -0 to 250 F (-0 to 2 C). Element Maximum Ambient Temperature: 250 F (2 C). Sensor Resistance (ohms) at 77 F (25 C): 20,000. Sensor Response: NTC non-linear. See form 63-707 for 20K ohm nominal resistance output in table form. Sensor Accuracy: ±0.36 F at 77 F (±0.2 C at 25 C). Accessories: 32006523-00: 20K Probe to allow replacement of old style C703D062- with non-threaded well. 500077-00 Stainless Steel 30 Well Assembly: /2 in. external and internal NPT threading. Use with C703D/ C70D. 5000775-00 Well Adapter: Used with C703D/C70D to allow threading sensor into previously-installed Series 000 32005960-00 Well. Table. Electronic Primary Sensor Application Guide. Model Control Application Element Insertion Length Dimensions (Fig.) C70B Duct discharge air 6 in. (52 mm) or 2 in. (305 mm) 3 C70C Duct discharge air 8 in. (57 mm) C703D, C70D Hot or chilled water (order immersion well separately) 5 in. (27 mm) (sensor), 2 (well) C703G, C70F Outdoor air C703J, C70J Duct discharge air (averaging sensor with elements) 2 ft (3.7m) 5 C70K Hot water (strap-on mounting) a 8 C70P Space air temperature (button probe) 6 C70R Duct discharge air (rigid copper averaging sensor) 2 ft (3.7m) or 2 ft (7.3m) 7 a Strap-on model not equipped with well; temperature sensed at surface of pipe. ORDERING INFORMATION Table 2. Specifications of the C703 Sensors used with the W927 Controller. Element Maximum Ambient Temperature Sensor Resistance in ohms Control Sensitivity in ohms per degree F (per degree C) for element operating range Model Element Operating Range 20K ohm Models a C70B,C,D,F,J,K,P,R -0 to 250 F (-0 to 2 C) 250 F (2 C) 20,000 at 77 F (25 C) C703 Sensors C703G2006-0 to 20 F (-0 to 9 C) 20 F (9 C) 75 at 90 F (32 C) 2.2 (3.) C703D2003 0 to 20 F ( to 5 C) 250 F (2 C) 097 at 77 F (25 C) b 2. (3.9) C703J2009 0 to 80 F ( to 82 C) 250 F (2 C) C703G20 c -0 to 20 F (-0 to 9 C) 20 F (9 C) 38 at 77 F (25 C) b 2. (3.9) a Nonlinear resistance decreases as temperature increases. b Resistance increases as temperature increases. c Use with T7350 Commercial Thermostat. When purchasing replacement and modernization products from your TRADELINE wholesaler or distributor, refer to the TRADELINE Catalog or price sheets for complete ordering number. If you have additional questions, need further information, or would like to comment on our products or services, please write or phone:. Your local Honeywell Automation and Control Products Sales Office (check white pages of your phone directory). 2. Honeywell Customer Care 885 Douglas Drive North Minneapolis, Minnesota 5522-386 In Canada Honeywell Limited/Honeywell Limitée, 35 Dynamic Drive, Scarborough, Ontario MV Z9. International Sales and Service Offices in all principal cities of the world. Manufacturing in Australia, Canada, Finland, France, Germany, Japan, Mexico, Netherlands, Spain, Taiwan, United Kingdom, U.S.A. 63-2590 2 2

6-/6 5 (27) /2 NPSM (3) / (6) -3/6 (07) M22596 Fig.. C703D, C70D dimensions in in. (mm). The C70D uses the 500077-00 Well Assembly. See Fig. 2 for dimensions. FITS /2 NPT TAPPED HOLE /2 NPSM INTERNALLY THREADED (26) 3/ (9) (02) 3/8 (0) M22597 Fig. 2. 500077-00 Immersion Well dimensions in in. (mm). C703B: 5-/6 (5) C70B: -5/8 (295) C70C: 7-5/8 (8) 3-7/8 (99) -3/6 (6) 7/6 (2) 5/6 (23) 3/ (9) -3/6 (07) /8 NPSM (3) M223 Fig. 3. C70B,C dimensions in in. (mm). 3 63-2590 2

3-5/8 (9) (25) 2-/ (57) 3/ (9) (25) -3/6 (07) 8-5/6 (2) 5 (27) THERMISTORS PLACED ON A 2 FOOT (3.7M) WIRE. M2233 7/8 (22) M2232 Fig. 5. C703J, C70J dimensions in in. (mm). Fig.. C703G, C70F dimensions in in. (mm). (26) 5/6 (8) 3/6 () (26) 7/8 (22) /6 (8) SPACER 5/8 (6) 3/8 IN.-6 THREAD M2282 Fig. 6. Dimensions of the C70P in in. (mm). 3-7/8 (99) -3/6 (6) 7/6 (2) 5/6 (23) 3/ (9) -3/6 (07) /8 NPSM (3) DEPENDING ON THE MODEL, THE ELEMENT LENGTH IS EITHER 2 FT (366 CM) OR 2 FT (732 CM). M2288 Fig. 7. C70R dimensions in in. (mm). 63-2590 2

-3/6 (07) -/2 (38) -/2 (38) 9/6 () -/ (32) 7-/8 (82) 5 (27) -3/6 (07) MAXIMUM PIPE DIAMETER SHOWN. MINIMUM PIPE DIAMETER: -5/8 () COPPER PLATE FOAM PAD M223 Fig. 8. C70K dimensions in in. (mm). INSTALLATION When Installing this Product.... Read these instructions carefully. Failure to follow them could damage the product or cause a hazardous condition. 2. Check the ratings given in the instructions and on the product to make sure the product is suitable for your application. 3. Installer must be a trained, experienced service technician.. After installation is complete, check out product operation as provided in these instructions. CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. Mounting The method of mounting depends on the particular application of the C70 Temperature Sensor. The following procedures include outdoor, duct, immersion well and strap-on applications. Also refer to the instructions for the electronic control. Outdoor Mounting (C703G, C70F) The C703G and C70F sense outdoor air temperature. Mount this control where it can sense average outdoor air temperature. Normally, the north side of a building provides a suitable location. C703G and C70F are weatherproof for outdoor use. Knockouts allow for /2 in. conduit connection.. Remove and set aside the wiring box cover. 2. Mount the sensor to standard /2 in. conduit. Mount sensor so that the element points down. 3. Make wiring connections using two wire nuts.. Reattach the wiring box cover. Duct Mounting The C703J, C70B,C,J can be mounted in a duct to sense air temperature. IMPORTANT Select a spot for the sensor where it will be exposed to average duct air temperature. Avoid locations where stratification can cause sensing errors. C70B,C MOUNTING. Cut a hole in the duct just large enough to accept the sensing element. 2. Use the sensor case to mark the locations of the pilot holes for the mounting screws. 3. Drill the pilot holes and fasten the sensor to the duct. 5 63-2590 2

C703J, C70J MOUNTING GROMMET (NOT INCLUDE) SENSING ELEMENTS () PLASTIC TIES (5) 3. Insert the averaging element into the duct through the hole.. Fasten the terminal box to the outside of the duct and thread the element through the hole and into the duct. 5. Use plastic wire ties to fasten the element to the supports. Seal the hole around the element with a rubber grommet. 6. Secure the end of the element to the duct on the support to prevent continuous flexing or abrasion. COPPER TUBING WITH SENSING ELEMENTS ( OR 9) SUPPORTS (2) DUCT M8929A Fig. 9. Duct cross section showing method of installing C703J, C70J Averaging Electronic Sensor.. Install two supports inside the duct to hold the averaging element. 2. Cut a 7/8 in. (22 mm) hole in the side of the duct to insert the averaging element. 3. Fasten the terminal box to the outside of the duct and thread the element through the hole and into the duct.. Use plastic wire ties to fasten the element to supports. Seal the hole around the element with a rubber grommet. 5. Secure the end of the element to the duct on the support to prevent continuous flexing or abrasion. IMPORTANT To assure that the C703J/C70J senses average duct temperature, position the temperature elements approximately as shown in Fig. 9. Do not allow the elements to touch or be close to the duct sides. DUCT SUPPORTS (2) NUMBER OF ELEMENTS DEPENDS ON LENGTH OF COPPER TUBING. PLASTIC TIES (5) M22820 Fig.. Duct cross section showing method of installing C70R Averaging Electronic Sensor. IMPORTANT To ensure that the C70R senses average duct temperature, position the temperature elements approximately as shown in Fig.. Do not allow the elements to touch or be close to the duct sides. When the sensor is used as a deck sensor in a multizone system, be sure to space the elements equally in the duct midstream as shown in Fig. 0. When the sensor is used as a deck sensor in a multizone system, be sure to space the elements equally in the duct midstream as shown in Fig. 2. Install one C703J/C70J just upstream from the cold deck zone dampers and the other C703J/C70J upstream from the hot deck zone dampers. Position the thermistors to sense the average deck temperature. Install one C70R just upstream from the cold deck zone dampers and the other C70R upstream from the hot deck zone dampers. Position the thermistors to sense the average deck temperature. SENSING ELEMENTS () COPPER TUBING WITH SENSING ELEMENTS ( OR 9) GROMMET (NOT FURNISHED) DUCT M8928A Fig. 0. Duct cross section showing method of installing C703J/C70J in a multizone system. C70R MOUNTING. Install two supports inside the duct to hold the averaging element. 2. Cut a 7/8 in. (22 mm) hole in the side of the duct. DUCT NUMBER OF ELEMENTS DEPENDS ON LENGTH OF COPPER TUBING. M2289 Fig. 2. Duct cross section showing method of installing C70R in a multizone system. 63-2590 2 6

Immersion Well Mounting (C703D, C70D) The C703D Sensor includes an immersion well. The C70D Sensor does not include a well. For the C70D, order the well as an accessory (part no.: 500077-00). installation if necessary). Thermal compound is recommended with the strap-on C70K Sensor. Locate the sensor on the discharge pipe within 3 feet (0.9m) of the boiler. See Fig.. When used on a boiler, follow the manufacturer instructions for location. If a tapped hole is not provided for the immersion well, provide one as follows:. Drain boiler and drill a 23/32 in. (8 mm) hole at the selected location. 2. Cut threads in the hole with a /2 in. (3 mm) by NPT tap. COPPER PLATE MUST MAKE GOOD CONTACT WITH METAL PIPE PIPE In other installations, mount the immersion well in an elbow with a heel outlet as shown in Fig. 3.. Drain the system, if you have not already done it, and open the tapped hole. 2. Put pipe joint compound on the threads of the immersion well and screw it into the tapped hole or elbow, tightening it securely. 3. Refill the system and check for leaks. Mount the C703D/C70D into the well: Mounting using previously installed Honeywell wells (part no.: 32005960-00) requires an adapter (part no.: 5000775-00).. When an adapter is required, first thread it into the well no more than one or two turns. 2. Slide the sensor into the well. 3. Rotate the sensor to thread it tightly into the adapter and the adapter tightly into the well. SENSING ELEMENT (SEALED IN STAINLESS STEEL TUBE INSIDE OF INSERTION WELL) /2 NPT (3) WORM GEAR M2236 Fig.. Strap-on mounting of C70K Sensor. Insulation around the contact area increases sensor accuracy. Button Probe Mounting The C70P Button Probe Sensor (20K ohm NTC) design simplifies mounting into a variety of standard structural materials. The locking nut can be used to secure the probe. See Fig. 6. The plastic spacer helps insulate the probe from drywall, wood, or other material in which the probe is mounted. See Fig. 7. The spacer is sized to fit snugly into /2 in. metal conduit. See Fig. 5. NOTES: The plastic spacer is threaded for easy installation. Use of both the locking nut and spacer requires cutting spacer to shorter length. M2235 Fig. 3. Method of mounting C703D/C70D Sensor. Strap-On Mounting (C70K) Strap-on mounting is well-suited for retrofit applications where installation costs can be reduced by not draining the system. The C70K Sensor mounts on metal pipes from -5/8 inch to five inches in diameter using the straps supplied. Clean the surface of the pipe where the sensor makes contact before mounting (remove insulation from the pipe at the point of C70P MOUNTING RECOMMENDATIONS Determine the proper location based upon the following: Mount the probe to an inside wall approximately 5 in. (372 mm) from the floor (or in the specified location) to allow exposure to the average zone temperature. Do not mount the probe to an outside wall, a wall containing waterpipes, or near air ducts. Avoid locations exposed to register discharge air, or radiation from lights, appliances, or the sun. M22797 Fig. 5. Mounting sensor in conduit. 7 63-2590 2

WIRING Fig. 6. Mounting sensor in wall with nut only. WALL WALL M22799 CAUTION Erratic System Operation Hazard. Failure to follow proper wiring practices can introduce disruptive electrical interference (noise). Keep wiring at least one foot away from large inductive loads such as motors line starters, lighting ballasts, and large power distribution panels. Shielded cable is required in installations where these guidelines cannot be met. Ground shield only to grounded controller case. CAUTION Electrical Shock or Equipment Damage Hazard. Can shock individuals or short equipment circuitry. Disconnect power supply before installation. IMPORTANT. All wiring must agree with applicable codes, ordinances and regulations. 2. Do not mount sensor in incorrect environment. 3. Wire according to the applicable controller instructions. OPERATION AND CHECKOUT Operation The C70 Temperature Sensors are designed for use with XL500, XL00, XL50, XL5, XL0, and Honeywell LCBS Controllers or any controller requiring 20K ohm NTC non-linear input. As the temperature at the C70 Sensor increases, the resistance of the sensor decreases, causing the controller to operate and offset the temperature change. M22798 Fig. 7. Mounting sensor in wall with spacer only. Checkout Refer to the applicable controller instructions when checking out the complete heating and cooling systems. To check out the sensors, move the thermostat or remote setpoint potentiometer below the temperature of the cooling or heating medium. Watch the motor, valve or damper for the correct movement. Automation and Control Solutions Honeywell International Inc. Honeywell Limited-Honeywell Limitée 985 Douglas Drive North 35 Dynamic Drive Golden Valley, MN 5522 Scarborough, Ontario MV Z9 customer.honeywell.com U.S. Registered Trademark 2005 Honeywell International Inc. 63-2590 2 B.B. Rev. 05-05