Multipoint temperature sensor

Similar documents
PESO. Temperature sensors with cables Thermocouples and RTD temperature probes ATEX I, e, t For use in areas with an explosion hazard

OPTIBAR DP 7060 Supplementary Instructions

OPTIBAR P 1010/2010 C Supplementary instructions

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-d.

Inductive slot sensor

Hazardous Areas - EXPLOSIONPROOF SOLENOIDS

VERSAFLOW VORTEX Supplementary instructions

REGULATIONS EUROPEAN ATEX DIRECTIVE. INTERNATIONAL SCHEME: IECEx AREAS CLASSIFICATION DEFINED BY DIRECTIVE 1999/92/EC

OPTIWAVE X500 Supplementary Instructions

Dual certification! Air handling units for potentially explosive atmospheres

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-nA.

ATEX, NOMENCLATURE AND CODING

Additional Operating Instructions SITRANS F. Vortex flowmeters. SITRANS FX330 Ex-i.

Technical Data. General specifications. Rated operating distance s n 5 mm

Technical Data. Dimensions

ATEX, NOMENCLATURE AND CODING

Translation of the assembly instructions with operating instructions and technical appendix

manual addendum DELPHI Ex

Regulated Ex-Heater HEX with internal controller, HEX with external controller II 3 G II 3 D

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Drive Technology \ Drive Automation \ System Integration \ Services * _0817* Inquiry Forms for Explosion-Proof Gearmotors

INSTRUCTION MANUAL IS-mB1 Minialite Intrinsically Safe Round LED Beacon

Technical Data. General specifications Switching element function Rated operating distance s n 4 mm

INSTRUCTION MANUAL (ATEX / IECEx)

Technical Data. Dimensions

Seat Ventilation offers an extensive range of ATEX certified products and is undertaking great efforts to extend this range even further.

Technical Data. General specifications Switching element function Rated operating distance s n 5 mm

Technical Data. General specifications Switching element function Rated operating distance s n 8 mm

ATM Lighting sp. z o.o

EtherCAT Box Modules (EPxxxx-xxxx)

Officine Meccaniche M.A.M. series for command, control, signaling and/or automation. DOCUMENT IS-EJB-A-14 rev. 0

Smart encoders & actuators

GTF 103-Ex. GREISINGER electronic GmbH D Regenstauf, Hans-Sachs-Straße 26. Temperature Probe for potentially explosive atmospheres

PEPPERL+FUCHS GmbH

TRASCO ATEX Couplings

Temperature sensors SensyTemp TSP Measuring insets TSA

Flameproof Manual Call Points

ANNEX GD-CERT-EX-EN SIT

NON ELECTRICAL EQUIPMENT IN HAZARDOUS AREAS

MANUAL Oil Level Sensor

Indoor/outdoor resistance thermometer Model TR60

ATM Lighting sp. z o.o

EU DECLARATION OF CONFORMITY

Materials Handling and Intralogistics. Industrial Trucks. In accordance with the Directive Equipment for potentially explosive atmospheres (ATEX)

Technical Data. Dimensions

ATEX 137. What it means for motor users

USER GUIDE EXPLOSION-PROOF TELEPHONES ATEX GASES AND DUSTS TYPE 227A1 IM2 FOR GROUP I MINING II 2GD FOR GROUP IIC AND IIIC GASES AND DUSTS

(German speaking trainers with English written slides)

Guidelines for Market Surveillance of Equipment for Explosive Environments (Hazardous Locations)

IECEx International Conference 2017 Shanghai, China. Electrical Installations Design, Selection, Erection and Inspection

Inspection Light LED 6149/2. Operating instructions EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN EN

Circulation heaters for ATEX/IECEx hazardous areas or in non-atex version

Technical Data. Dimensions

Flammable gases Detectors. Model DAX 03F DAX 03F- C DAX 03F- H. Note for installation, use and maintenance. Version 1.2

User manual. Explosion-safe window air conditioning system Type series AR-054. II 3 G Ex ic nac h IIC T3 Gc

The R. STAHL Technology Group Worldwide Success with Competence and Customer Support

Compliance with EN : 2006 Electrical apparatus for explosive atmospheres Type of Protection «n» for Zone 2

Operating Manual MS220DA

INSTRUCTION MANUAL (ATEX / IECEx)

Operating Instructions for Limit switch Model: NBK-R NBK-RM NBK-RT NBK-RA

Survey of electrical equipment installed in hazardous areas on tankers

Duct heaters for ATEX/IECEx hazardous areas or in non-atex version

Overview of Hazardous Locations as They Relate to Solenoid Valves

Immersion heaters for ATEX/IECEx hazardous areas or in non-atex version

EUROPUMP ATEX Guideline Part II

EQUIPMENT INTENDED FOR USE IN POTENTIALLY EXPLOSIVE ATMOSPHERES (ATEX)

INSTALLATION OPERATION AND MAINTENANCE INSTRUCTIONS FAW, FAW-C & FAW-C-T TYPE AIR WARMERS FCR & FCR-A TYPE CONVECTORS

Erik Leider Project Engineer Hazardous Locations, Gas & Oil Underwriters Laboratories

EUROPEAN DIRECTIVES Explosive atmospheres ATEX 2014/34/EU

1. GENERAL TECHNICAL INFORMATION

RE: USE OF FIREPRO IN POTENTIALLY EXPLOSIVE ATMOSPHERES

SITRANS T. SITRANS T Explosion protected temperature sensor. General information. Marking of the degree of protection. Range of uses.

Technical Data. General specifications Switching element function DC Dual NC Rated operating distance s n 3 mm

4) Intrinsic Safety Certification

DSF xx10.xx xhv Ex-Atex Hall Effect Single Channel Speed Sensor

Industrial Cast-in Circulation Heaters for ATEX/IECEx hazardous areas or in non-atex version

Additional Information. Introduction. Temperature transmitter for all communications protocols. Redundancy thanks to two inputs. Measurement made easy

Beamex. Calibration White Paper. Calibration in hazardous areas

INSTRUCTION MANUAL (ATEX/IECEx/SIL2) BExBG05D-SIL Flameproof Xenon SIL 2 Beacons For use in Flammable Gas and Dust Atmospheres

Supplementary Installation and Operating Instructions. Category II2G

INSTRUCTION & SERVICE MANUAL

Drive systems for the chemical, oil and gas industry. Electric drives and systems

Explosion Protection in Europe

ATEX GUIDE. A short introduction to ATEX Terminology. Equipment for use in flammable atmospheres. Directive 94/9/EC

Explosion-protected actuator Page 259 of 292

Immersion heating type IN 16.. PTB 99 ATEX 1009 U. May thuba Ltd. CH-4015 Basle Telefon Telefax

Guide for hazardous areas

Manual Power relay SR853

Selection of Explosion Protected Equipment for Hazardous Locations. Compiled by: Pieter Coetzee ZONE 2 ZONE 1 ZONE 0.

RTK Instruments Limited St James Business Park, Knaresborough, North Yorkshire, England. HG5 8PJ

ATEX Safety Switches. More than safety.

MANUAL Overflow sensor NVF-104/34-PF

IECEx TEST REPORT IEC Explosive atmospheres Part 0: Equipment General requirements

Certification Supplement Manual

STAINLESS STEEL FLAMMABLE GAS DETECTOR DAX 3F-I INSTALLATION, OPERATING AND MAINTENANCE INSTRUCTIONS. DAX3FI_MAN01_EN Ver. V1R2

Beamex Calibration White Paper. Calibration in hazardous areas

AND INSTALLATION MANUAL

SEK-3 Marine Grounding System

Certified drive and control products for explosion protection

Rosemount 214C Sensor. Quick Start Guide , Rev AF August 2017

Transcription:

Multipoint temperature sensor ATEX e / t for use in areas with an explosion hazard Persons concerned: Experienced professional electricians as per EU Directive 1999/92/EC and trained personnel B 903530.0.0 Operating Manual Writer : C. Noussbaum 2014-05-01/00615230

Safety Information General Information This manual contains information that must be observed in the interest of your own safety and to avoid damage to assets. This information is supported by symbols which are used in this manual as follows. Please read this manual before commissioning the device. Keep the manual in a place accessible to all users at all times. Telephone : 03 87 37 53 00 Fax : 03 87 37 89 00 E-mail : info.fr@jumo.net Sales support service: 0892 700 733 (0,337 /min) If difficulties occur during commissioning, please refrain from carrying out any manipulations that could jeopardize your warranty rights. 2

Contents Page 1 Equipment and intended application 5 2 Marking 6 3 Safety notes 6 4 Conformance with standards 7 5 Technical data, explanation and case study 7 5.1 Protection sleeve constant 7 5.2 Increased safety Ex e protection 8 5.3 Use in areas with a dust explosion hazard 9 6 Installation 10 7 Maintenance 10 8 Connection for silos 11 9 Declaration of conformity, data sheet/detail drawing 11 3

1 Equipment and intended application The multipoint temperature sensors from Jumo are used for temperature measurement in storage of cereals, of flour, dried mud, sugar refinery, as well as for dusts. Resistance probes for silos may be anchored to the structure or to a concrete screed, as preferred. Connection housings in aluminium or stainless steel with IP 6x protection indices allow the replacement of the measuring element when the silo is full. Connection of the measuring cable to the IP 6x housing compliant with directive 94/9/EC. Pt100 or Pt1000 resistive elements compliant with standard EN60751 or NTC and PTC resistors offer high precision and repeatability of measurements. - Electrostatic charges on polypropylene suspension cable - The results of report 60033806-532988 of tests carried out from 17 to 24 May 2005 in LCIE provide a maximum spark energy value of < 0.8 mj in the most severe case. - The usual values for the MIE (Minimum Ignition Energy) of the different stored products are about a few tens or hundreds of mj. Products MIE (mj) Cloud SIT ( C) Wheat 160 500 Wheat flour 60 440 Starch 25 400 Malt 35 400 Refined sugar 30 370 Wood 40 470 Our suspension cable with polypropylene outer sheath satisfies entirely the application temperature measurement in food storage silos, in areas with a dust explosion hazard. - Using the multipoint sensor with polypropylene sheath is strictly prohibited in zone (G) gases, this type of sheath does not meet the criteria of groups of gas explosions because the charge levels are > than the recommended 60nC by the C.4.2.4 appendix C of NF EN 13463-1 (2002). For this kind of application is the stainless steel sheath recommended.. 4

2 Marking Example of sensor marking : JUMO 57075 METZ (1) Type : Multipoint (2) Manufacturing no.: 402743/0010 (3) Year of manufacture : 2014 (4) (5) CE0359 II 1 D Ex ta IIIC T85 C Da (6) LCIE 00 ATEX 6015 X (7) Un 28V In 2mA WARNING DO NOT OPEN UNDER VOLTAGE - SEE INSTRUCTIONS (1) Manufacturer's address (2) Type of sensor (3) Manufacturing number: order number + position (4) Notified body: 0359 = Intertek (5) Ex marking of group and category (6) Ex marking for dust zone (IIIC, conductive dust) (7) Ex attestation number 3 Safety notes The device is designed exclusively for use within the values indicated on the identification plate and in the technical specifications (see section on technical specifications in the operating manual or the technical data sheet). The maximum service temperature may not be exceeded. The permissible ambient temperature may not be exceeded. The protection type of the device must be followed during the implementation. Upon installation, sensor connection must comply with the electrical values determined in Ex attestations. It is not permissible to make any alterations to the sensors. In such a case, proper fault-free operation is no longer assured. The guarantee is also invalidated by any alterations. When exchanging measuring inserts, use only original JUMO replacement parts of the same type Make sure the cable or insulation are not damaged while mounting the sensor on the process. The cable is to be installed so as to be fixed. While mounting, removing or operating the sensor, make sure that no pulling force or pressure above 17 Newton is applied on the cable. The technical data that are relevant to the use of the device in an area with an explosion hazard (Ex area) are presented in the corresponding data sheet. In order to prevent temperature rises due to the accumulation or transfer of heat, keep away from hot parts of the installation and thermal insulation systems, and provide for heat dissipation through unhampered air circulation. The national and international safety and accident prevention regulations must be followed for installing and working on or with the devices. Furthermore, the operator of the plant or installation is responsible for the observance of legal requirements. 5

4 Conformance with standards Type ATEX type examination EN standards Multipoints LCIE 00 / ATEX 6015 X EN 60079-39 (2012) Multipoints LCIE 00 / ATEX 6015 X EN 60079-7(2007) Protection type protection by enclosures t Increased safety, Ex e protection 5 Technical Data CAUTION: for specific data, see the attached technical data sheet/detail drawing and/or the label that is affixed to theses operating instructions. 5.1 Protection sleeve constant Electrical values Un 28 V In 2 ma The sensing element in a RTD temperature probe carries a current or a leakage current during measurement. The surface heating itself is influenced by the design of the temperature probe, by the ambient conditions (thermal coupling with the medium being measured) and the power that is applied. The self-heating behavior of the thermometer is characterized by the thermowell constant SK (in C/W), which represents the increase in the surface temperature (in still air) above the ambient temperature as a function of the applied power. The thermowell constant SK is determined by JUMO, and can be found in the attached technical data sheet or on the affixed label. The user must determine whether the thermometer is suitable for the measurement application and the connected equipment under the given conditions. The maximum permissible measured temperature at the probe tip can be derived from the following equation: T S = TK PI x SK T S : Maximum permissible temperature at the probe tip T K : Maximum permissible surface temperature, depending on the temperature class P i : Power in the certified intrinsically safe circuit SK : Protection sleeve constant (see technical data sheet) 6

The following diagram illustrates the self-heating of the probe surface of a thermocouple as a function of the applied power and thus the temperature arising within the probe. (Self-heating is independent of the protection type, and also applies to the flameproof enclosure). Protection sleeve constant from the multipoint sensor with polypropylene suspension cable: Pt 100 Ω : 10,5 K/W Pt 1000 Ω : 12 K/W Self-heating of a Pt100 RTD temperature probe Pt100 Example : Protection sleeve constant SK = 10,5K/W Maximum power in the circuit P = 0,5 K TS = 85 C 0,5 W x 10,5 K/W TS = 85 C 5,25 K = 79.5 C So the maximum temperature (the medium temperature being measured) on the probe tip must not exceed 79,5 C, since in the event of a fault it is possible that the limit for the temperature class will be exceeded. DANGER OF EXPLOSION! 5.2 Increased safety Ex e protection This protection mode consists in applying measures in order to prevent, using a high safety coefficient, the possibility of excessive temperatures and the occurrence of electric arcs or sparks inside or on the outer parts of the electrical equipment that do not occur in normal service or in the event of failure. Increased safety must not necessarily be connected to an intrinsically safe electrical circuit; however, care must be taken to ensure that the heating of the probe remains limited in all operating modes, as described in paragraph 5.1 The Ex e increased safety alone is not sufficient for use in zone 0 (G) or 20 (D)! Two independent protection modes and/or a separating element to separate the zones are required. The equipment has accessories (ATEX/IECEx housings, ATEX/IECEx terminal boxes or glands) in accordance with standard EN 60079-0/IEC 60079-0 and EN 60079-7/IEC 60079-7. The transfer of the outer ground must be connected to the earth or integrated into the equipotential bonding of the site.

5.3 Use in areas with an explosion hazard caused by dust The following temperature values must be taken into account for applications in areas with a dust explosion hazard: Applicable to all zones: The surface temperature of the equipment must not rise to a level that could ignite swirling dust or dust deposits on the equipment. This is achieved through the following regulations: No dust deposit The surface temperature must not exceed 2/3 of the ignition temperature (in C) for the corresponding dust-air mixture. With dust deposit Surfaces on which a dangerous accumulation of smolderable dust cannot be prevented must not have a temperature that is higher than 75K below the smoldering temperature of the dust concerned. If layers thicker than 5 mm occur, a further reduction of the surface temperature must be applied. Note In this case, "surface" means the exterior surface of the equipment, see also 60079-14. The ignition or smoldering temperature of the dust or dust-air mixture that is present must be defined or determined by the operator of the plant or system!! 8

6 Installation The valid European and national regulations must be observed for installation and operation. The generally accepted state of the art and these operating instructions must be applied. Temperature sensors from JUMO from JUMO are used to measure temperature within areas with an explosion hazard, containing flammable or non-flammable liquids, gases or gas-air mixtures or potentially explosive dusts. The feed wire of the RTD temperature probe must be fixed in position when mounted to containers or pipelines that contain potentially explosive gas/air mixtures (zone 0, 1G or EPL Ga) or dust (zone 20, 1D or EPL Da). The equipotential bonding (earth connection of the device) include the entire wiring of the measuring circuit! Metallic connector housings must be grounded via the connecting cables, for equipotential bonding. Non-metallic connector housings must not exceed the max. surface area specified by EN 60079-26. Norm EN 60079-14 "Explosive atmospheres - Part 14: Electrical installations design, selection and erection" needs to be observed! Caution: In all cases, zoning is the responsibility of the plant/system operator, and not of the manufacturer/supplier of the equipment! Zone separation Gases, mists, vapors Dusts Potentially explosive atmosphere present Guide values Zone 0 Zone 20 continually, long-term, or frequently 1000 hours/year Zone 1 Zone 21 occasionally 10 1000 hours/year Zone 2 Zone 22 infrequently, short-term 10 hours/year 7 Maintenance The valid European and national regulations must be observed for maintenance, servicing and testing. During maintenance, all parts must be tested that are relevant for the Ex (explosion protection) rating.. In addition, thermometers with a plastic terminal head as well as all plastic components (e.g. connectors and the like) must only be cleaned with a damp cloth, to avoid building up an electrostatic charge. The deterioration of components such as the housing, cable seal or joints cancels the class of protection IP of the multipoint temperature sensor. 9

8 Connection for silos (applies to Pt500 and Pt1000, for JUMO resistance probes with cable connecting head) Measuring points on sensors of silos Pt100 3-wire circuit Pt1000 2-wire circuit High High Measuring point 6 Blue/ purple - grey Measuring point 9 purple /purple Measuring point 5 2 x red/ yellow Measuring point 8 green /green Measuring point 4 2 x black/yellow Measuring point 7 red/red Measuring point 3 2 x orange/ Blue Measuring point 6 Orange/orange Measuring point 2 2 x green/purple Measuring point 5 black /black Measuring point 1 2 x white / grey Measuring point 4 yellow /yellow Measuring point 3 grey /grey Low Measuring point 2 Blue / Blue Cable PVC/PVC. Thermoplastic Measuring point 1 white/ white 18 x 0,14 mm² + 1 yellow/green Part no : 00422034 Low Cable PVC/PVC Thermoplastic 18 x 0,14 mm² + 1 yellow/green Part no : 00422034 9 Attestations and certificats Download Ex attestations and IECEx certificates from our website : www.jumo.fr 10

JUMO GmbH & Co. KG Adresse : Moritz-Juchheim-Straße 1 36039 Fulda, Allemagne Adresse de livraison : Mackenrodtstraße 14 36039 Fulda, Allemagne Adresse postale : 36035 Fulda, Allemagne Téléphone : +49 661 6003-0 Télécopieur : +49 661 6003-500 E-Mail : mail@jumo.net Internet : www.jumo.net JUMO Régulation SAS Actipôle Borny 7 rue des Drapiers B.P. 45200 57075 Metz Cedex 3, France Téléphone : +33 3 87 37 53 00 Télécopieur : +33 3 87 37 89 00 E-Mail : info.fr@jumo.net Internet : www.jumo.fr 11