Condumax II Hydrocarbon Dew-Point Analyzer

Similar documents
Condumax II Hydrocarbon Dew-Point Analyzer

Condumax II Hydrocarbon Dew-Point Analyzer

Condumax II. Condumax II. Hydrocarbon Dew-Point Analyser. Automatic, on-line measurement of hydrocarbon and water dew point in natural gas

Condumax II Hydrocarbon Dew-Point Analyzer

Moisture and Hydrocarbon Dew-Point Measurement

Moisture and Hydrocarbon Dew Point Measurement

Dew-Point Transmitters and Instruments

Promet I.S. Promet I.S. Process Moisture Analyser

FLEXIBLE, AFFORDABLE, HIGH SPECIFICATION OXYGEN GAS ANALYSIS DESIGNED FOR DEMANDING HAZARDOUS AREA PROCESS CONTROL APPLICATIONS.

All icon products are. Easy to use: with an intuitive glass touch-screen, wipe-clean graphic user interface with multi-language options.

On-line Side Stream Oil in Water Analyser - Model OIW-EX 100 or OIW-EX 1000

In-line Oil in Water Analyser - Model OIW-EX100P and OIW-EX1000P

Dräger Polytron Fixed Gas Detector. Dräger Polytron 5700 Infrared DrägerSensor PIR 7000 to detect combustible gases and vapors

Accurate, cost-saving and reliable Natural gas analyzer SITRANS CV SITRANS CV. Answers for industry.

APPLIED. OMA-300 Hydrogen Sulfide Analyzer H 2. Ex p. Ex d. The world s safest continuous H 2. S analyzer. The OMA continuously measures H 2

MICHELL GROUP. Advanced Industrial Hygrometry and Process Instrumentation. Company Profile, 2011

IR4000. Point Infrared Combustible Gas Detection System. The Reliable and Flexible Safety Solution That s Low Maintenance

INFRARED PRODUCTS FOR MONITORING SMOKELESS FLARES, PILOTS, AND FLAME INTENSITY

Pre-engineered Sample Systems for TALYS ASP400 series with fiber optic interface

OMA-300 Process Analyzer

THE STANDARD OF EXCELLENCE WDG-V SERIES COMBUSTION ANALYZERS

Series 3300 TELEDYNE ANALYTICAL INSTRUMENTS. The 3300 series of low cost, microprocessorbased

Dew Point Mirror 373. High Precision. Fast Response. Wide Measuring Range. Laboratory Reference. Touch Screen. Full Color High Resolution LCD

Technical data sheet TDS0060

Model D12-IR. Digital Gas Transmitter...

Dräger Polytron 5700 IR Detection of flammable gases and vapours

A New Standard of Excellence

Dräger Polytron 8000 Stationary gas detector (EC)

icount Oil Sampler (IOS) Portable Condition Monitoring for Hydraulic Oil and Fuel Systems

SEC SIGNATURE ETO MONITOR TRAINING SENSOR ELECTRONICS CORPORATION

Danfoss gas detection unit Type GD Heavy Duty

continuous emissions monitoring Combustion & Environmental Monitoring

973 Dew Point Mirror. Portable Industrial Chilled Mirror Hygrometer. Typical applications: REFLECTING YOUR STANDARDS

New Features TDLS 200. The Process TDLS Solution. Tunable Diode Laser Spectroscopy (TDLS) Analyzer.

Dräger Polytron 8100 EC Detection of toxic gases and oxygen

CO 2 Laser. High Reliability and Performance

EMS510 PS-1 COMPLIANT OPACITY/DUST MONITOR

PUV, PIR and PFO Series BROCHURE

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

SENSE Instruments CO., LTD. Data sheet Gas detector Page 1 / 5. Gas detector

Dräger Flame 2500 Flame Detection

Zircomat Oxygen Analyzers

Flame Detection Jon Sarfas

Enraf Servo Gauge 854 XTG

CALIDUS tm the Modular micro Gas Chromatograph

Dräger Polytron 5720 IR Toxic Gas Detection

IR15 Dual Gas Series Datasheet

Process Gas Chromatograph

Dräger Flame 2100 Flame Detection

Zareba Sensepoint Pro

Dräger Polytron 8100 EC Detection of toxic gases and vapors

IR25 Dual Gas Series Datasheet

DEW-POINT SENSOR TRAINING. Moisture Sensors DP & Rh The basic low cost solution With a wide range

WASTEWATER Online UV%Transmission Analyzer

AS950 REFRIGERATED SAMPLERS

Dräger Polytron 8700 IR Detection of flammable gases and vapors

OLCT 700 & 710. Certifications FIXED GAS DETECTION. Better detection. Better protection.

CLARITY II TURBIDIMETER

Dependable Solutions for Gas Detection

PRODUCT GUIDE. ionscience.com Unrivalled Gas Detection.

Hygro Transducer, Hygrothermal Transducer, and CO 2 Measuring Probe for Building Management and Climate Monitoring

Flexible Air-sampling Smoke Detection

Dräger X-am 7000 Multi-Gas Detection

Dräger Polytron 8700 IR Detection of flammable gases and vapors

Connected Industrial. EC 350 PTZ GAS VOLUME CORRECTORS ENABLING PRECISION GAS MEASUREMENT Proven Technology. Superior Performance.

TYPE CM-2201 NELSON SINGLE POINT CIRCUIT MANAGEMENT SYSTEM

Dräger Polytron 5200 CAT Detection of flammable gases and vapours

Using the DewMaster Deluxe Dew Point/ Humidity Hygrometer

Dräger Polytron 8310 IR Detection of flammable gases and vapour

S5000 Gas Monitor. GMS5000.com

for Drinking Water Systems

SAFETY CERTIFIED MODEL FP-700 COMBUSTIBLE GAS DETECTOR

Technical Information OUSAF44

Datalogging as standard

Technical Summary. Searchpoint Optima Plus Specification. Output ma sink or source, (Default current source) 0-4 ma (Default 4 ma)

SIL 2. Ultima X Series Gas Monitors CERTIFIED

OIL FILM DETECTOR (Flame-proof Version) SODL-1600

APPLICATION DATA SHEET

DET-TRONICS. SPECIFICATION DATA Eagle Quantum Premier Fire and Gas Detection / Releasing System APPLICATION FEATURES

EC 350 PTZ Gas Volume Correctors Enabling Precision Gas Measurement

APPLIED. OMA-406R Rackmount Process Analyzer

Technical data sheet TDS0034

The SharpEye 40/40I (IR3) Flame Detection

5New features & EXtreme design, now with HART Protocol and DuraSource Technology. Ultima X Series Gas Monitors

Industrial Grade Gas Detection

Industrial Grade Gas Detection

Dräger Polytron 8200 CAT Detection of flammable gases and vapors

Searchpoint Optima Plus

Industrial Grade Gas Detection Detecting The Difference

Process Gas Chromatograph

Eliminating False Alarms in Toxic Gas Detection. Jason Schexnayder Sales Manager - Americas

573 Dew Point Mirror. Industrial Chilled Mirror Hygrometer. Typical applications:

Dräger Polytron 8720 IR Detection of carbon dioxide

Turbidity Systems. Inline Turbidity Measurements For More Visibility Into Your Process. INGOLD Leading Process Analytics

Laboratory Enclosed Scroll Air Compressor System with Premium NFPA Controls

Using the Model 1500 Portable Chilled Mirror Hygrometer

Installation, Operation, & Maintenance Manual. MODEL: MPRVSS (NGL Sr.), MPRVSSJR (NGL Jr.)

2100 Series Laboratory Turbidimeters. Pioneering technology in turbidity monitoring.

Series 155. Mass Flow Computers TECHNICAL SPECIFICATIONS

Series 9000 Total Hydrocarbon Analyzer

Transcription:

Condumax II Hydrocarbon Dew-Point Analyzer Automatic, on-line measurement of hydrocarbon and water dew point in natural gas. Process Analyzers Highlights Fully automatic on-line analysis Objective, highly repeatable measurement 0.5 C hydrocarbon dew-point accuracy Fundamental chilled mirror principle Patented detection technique Self-cleaning No purge or cooling gas needed Optional water dew-point analysis Modbus RTU IECEx, ATEX, C CSA US and GOST Ex certifications Applications Natural gas processing Protection of turbo-expander plant Gas quality measurements at custody transfer Transmission pipeline monitoring Confirmation and control of fuel gas superheat to turbine power plant www.michell.com

Process Analyzers Hydrocarbon Dew Point: A Critical Natural Gas Quality Parameter For natural gas producers, pipeline operators and direct contract buyers, hydrocarbon dew point is difficult to measure and control but it is vital to avoid custody transfer disputes frequently resulting in shut-ins due to today s tighter contractual limits. Accurate hydrocarbon dew-point measurement and control has emerged as THE issue at gas quality conferences, including the AGA. The need for harmonization of analysis methods to ensure consistent best practice is being promoted by research groups within independent organizations such as API in North America and GTE and GERG in Europe. These groups are evaluating the relationship between direct hydrocarbon dew-point measurement, the manual Bureau of Mines (BOM) method, potential hydrocarbon liquid content (PHLC) and analytical techniques such as gas chromatography (GC) with various Equations of State (EOS) software packages. The direct chilled mirror technique incorporated in the Michell Instruments Condumax II is the definitive method of measuring hydrocarbon dew point, and is preferred by most gas producers, pipeline operators and direct contract buyers around the world. Since 1986, the original Condumax enabled users to make direct fundamental measurements automatically, on-line, with minimal maintenance demands in service and with a level of objectivity previously impossible to achieve. Condumax II extends this capability, adding the latest features and specifications to a proven and patented measurement technique. Condumax II offers the user the opportunity to standardize on a hydrocarbon dew-point measurement technology that provides excellent correlation to PHLC, EOS calculations of extended composition analysis by laboratory GC and the BOM method in an instrument that is simple to install and virtually maintenance free. The Dark Spot Measurement Principle Condumax II uses a patented chilled mirror optical measurement technique that is radically different to that of any other instrument. Sensitivity of better than 1 ppm molar (1mg/ m 3 ) of condensed hydrocarbons enables the analyzer to detect the almost invisible films of condensate that are characteristic of hydrocarbon gases at dew point, due to their low surface tension and colorless appearance. The result is a breakthrough in accuracy and repeatability. The optical sensor comprises an acid etched, semi-matt stainless steel mirror surface with a central conical-shaped depression, which is chilled during a measurement cycle. Collimated visible red light is focused onto the central region of the optical surface. In the dry condition, the incident light beam is dispersed by the matt surface providing a base signal to the optical detector. During a measurement cycle, hydrocarbon condensate is formed on the optical surface and it becomes reflective due to the low surface tension of the condensate. An annular ring of light forms around the detector and there is a dramatic reduction in the scattered light intensity within the central Dark Spot region. This secondary effect is monitored and interpreted. The Dark Spot detection technique utilizes the physical characteristic of hydrocarbon condensate that makes it so difficult to detect in a manual visual dew-point meter (BOM). When a predetermined layer of condensate has been detected, the instrument records the temperature of the optical surface as the hydrocarbon dew point. In the subsequent recovery cycle, the optical surface is actively heated typically to +50 C to evaporate the condensates back into the flowing gas sample. This fully automatic process is complete in under ten minutes. Sensor Cell The design of the Condumax II sensor cell is critical to its dynamic performance. This cell combines the optical detection system, Dark Spot sensor, thermocouple and three-stage Peltier heat-pump in a stainless steel cell assembly. The cell carries an operating pressure rating of 100 barg and achieves a measurement depression range (ΔT) of up to -55K from the analyzer operating temperature. Flow De-coupling A flow de-coupling method is used in order to achieve maximum accuracy. Discrete measurement cycles, at user definable intervals, lock a fixed sample of the hydrocarbon gas mixture into the sensor cell. As the optical surface is chilled, sequential condensation of hydrocarbon components occurs with the heaviest hydrocarbons condensing first. Thus a flowing sample would lead to a falsely high indication of the hydrocarbon dewpoint temperature of the gas. The fixed sample method used in the Condumax II ensures representative condensation of all hydrocarbon components and prevents preferential drop-out of heavy ends that occur with flowing samples often used by other measurement methods. Dark Spot Measurement Principle 2017 Michell Instruments

Intelligent Control The Condumax II has a fully automatic, intuitive and intelligent control system that improves accuracy, sensitivity and reproducibility under any operating condition. A three-stage Peltier heat-pump under powerful digital command allows Condumax II to vary its chill rate to enable detection of the smallest amount of condensate on the optical surface. During start-up, Condumax II will perform a measurement cycle at a standard chill rate in order to range-find the hydrocarbon dew-point level. On subsequent cycles, the previous measured value is used to determine an optimized chill rate that will cause the sensor surface to cool quickly in the initial phase, but reduce its chill rate to 0.05 C/sec as it approaches the hydrocarbon dew point. This gives the user previously unattainable levels of precision and reproducibility and allows easy harmonization with other HCDP measurement techniques or measurement practices of individual users. Condumax II can also operate in Condensate Mode in order to give reliable PHLC measurement. In conventional dew-point measurement mode, analysis is performed at the cricondentherm condition or at user required pressure level. Condumax II also enables the user to determine the phase envelope of their gas through direct measurements at varying pressures. Condumax II is designed for easy operation, with innovative touch-screen control of all functions through the simple user menu that can be viewed in complete safety within the hazardous area environment on the high-resolution vacuum fluorescent alphanumeric display. Sampling system features Microporous membrane filter Heated pressure regulator Heated enclosure (option) Sample connections Optional combined water and hydrocarbon dew-point analysis 0.5 C hydrocarbon dew-point accuracy Fully automatic on-line analysis Modubus RTU Condumax II Sampling System (outdoor version) Condumax II Sampling System 4-20 ma OUTPUT PG1 SAMPLE GAS INLET BV1 F1 PR1 Hydrocarbon Dew Point NRV1 FV1 FM1 BV2 SAMPLE GAS OUTLET CONDUMAX Il Water Dew Point PR3 NRV3 FM3 BYPASS FLOW PR2 NRV2 FM2 BV3 LETDOWN GAS VENT BY OTHERS BY MICHELL 2017 Michell Instruments

Process Analyzers System Description Main Unit The Condumax II Main Unit contains all of the critical components in a single explosion proof/flameproof enclosure for installation in Zone 1 or 2 (Class 1, Div. 1 and 2 areas). The Dark Spot sensor cell and optional water dew-point sensor are mounted inside the unit in conjunction with the pressure transducers, flow switches, measurement electronics and display. Flame arrestors on the gas inlet and outlet ports provide safety protection. Electrical connections are made through cable glands at the base of the enclosure. The main unit is a fully functional hydrocarbon dew-point analyzer and requires only a clean, pre-conditioned gas sample and AC power for its operation. Simultaneous Water Dew-Point Analysis Water dew-point measurement is of equal importance to hydrocarbon dew point for all gas producers and pipeline operators. Optional second measurement channel utilizing the advanced Michell Ceramic Moisture Sensor, proven in over 1,000 petrochemical natural gas plant installations worldwide, to provide continuous on-line analysis to enable Condumax II to confirm conformance to both dew point gas quality specifications. Sampling System Indoor and outdoor sampling systems are available, providing comprehensive sample conditioning of natural gas at any pressure up to 138 barg for the standard design. The sampling system includes pressure regulation, flow control and most importantly micro-porous membrane filtration with by-pass arrangement and condensate drain to give fast response and protection from liquid hydrocarbon/glycol contamination. Dual channel sampling is available for the combined hydrocarbon/ water dew point analyzer package. The outdoor version is housed in an IP66 rated, insulated stainless steel enclosure. The optional thermostatically controlled heating ensures reliable operation with no condensate or water drop-out prior to measurement. For both the indoor and outdoor sampling systems, the Condumax II Main Unit is mounted integral to the Sampling System. Condumax II Main Unit Human Interface The Condumax II is designed to be flexible in terms of measurement display and connectivity to other equipment. As standard, Condumax II provides a multi-function vacuum fluorescent display on the Main Unit that shows all measurement parameters and allows the user to adjust certain control parameters, view log data, max/min statistics etc. In addition, Condumax II provides two 4-20 ma outputs, configurable from the Main Unit user interface for any combination of measurement parameters. A digital output using Modbus RTU protocol is provided, for connection to an external computer, DCS or PLC system located in a safe area. Active X controls are an available option for integration in DCS systems. www.michell.com

Process Analyzers Technical Specifications Hydrocarbon Dew-Point Measurement Measuring technique Sensor cooling Maximum range Accuracy Sample flow Measurement frequency Operating Pressure Dark Spot fixed sample analysis. Direct photo-detection of hydrocarbon condensate at hydrocarbon dew-point temperature Automatic via 3-stage Peltier effect electronic cooler under adaptive control Up to Δ -55K measurement depression from Main Unit operating temperature ±0.5 C hydrocarbon dew point (single and multiple condensable component analysis) 0.03 m 3 /hr (0.5 Nl/min) - alarm standard 6 cycles/hour (recommended) 12 cycles/hour (maximum) Max. 100 barg (1450 psig) Water Dew-Point Measurement (optional) Measuring technique Units moisture content Resolution Range Accuracy Sample flow Temperature Coefficient Operating Pressure Michell Ceramic Moisture Sensor C and F water dew point; lbs/mmscf; mg/m 3, ppm V 0.1 C, 0.1 F Calibrated from -100 to +20 C dew point ±1 C from -59 to +20 C dew point ±2 C from -100 to -60 C dew point 0.06 to 0.3 m 3 /hr (1 to 5 Nl/min) - alarm standard Algorithm compensation (-20 to +50 C) Max. 138 barg (2000 psig) Pressure Measurement(s) Hydrocarbon dew-point analysis pressure Optional water dew-point process pressure Units Resolution Range Accuracy MPa, barg, psig 0.1 MPa and barg, 1 psig HC dew point: 0 to 100 barg Water dew point: 0 to 200 barg ±0.25% FS Hydrocarbon Dew-Point Analyzer Resolution Sample gas supply Enclosure Sample gas connections Operating environment Power supply Weight Integrated display/ keyboard Outputs Alarms Hydrocarbon and water dew point: 0.1 C Natural gas up to 100 barg, pressure regulated in sampling system EExd cast enclosure with removable glass window viewing port. Internally heated for condensation protection 1/8 NPT (ATEX / IECEx) or 1/4 NPT (CSA) female ports for both hydrocarbon and water dew-point channels; Sampling system: 6mm OD or 1/4 OD Indoors/Outdoors -20 to +50 C Max 95% RH 90 to 260 V AC 50/60 Hz, 125 W Main Unit; 300W c/w indoor sampling system; 400W c/w outdoor sampling system Main Unit 22.5kg 60kg (approx) c/w Sampling system (indoor) 75kg (approx) c/w Sampling system (outdoor) Touch screen with vacuum fluorescent display Modbus RTU, RS485 @ 9600 baud rate. Two 4-20 ma linear (non-isolated) outputs, user configurable for any combination of dew point or pressure parameters Process and analyzer status via software register and display annotation. Integrated low flow alarms for each sample flow. Analyzer status fault flag 23 ma on ma output 1 Certification Hazardous area certification Pattern approval ATEX: II 2G Ex d IIB + H2 Gb IECEx: Ex d IIB + H2 Gb Tamb -40 C to +45 C T4 Tamb -40 C to +60 C T3 ccsaus: Class I, Division 1, Group B, C, & D T4 *TC TR: 1Ex d IIB+H2 T4, T3 Gb GOST-R, GOST-K, GOST-T *Available to customer specific order (consult Michell Instruments) For full details of configurations and options, please refer to the Condumax II Order Codes list. Available from the Michell Instruments website or from your local Michell Instruments office. Condumax II Transportable Hydrocarbon & Water Dew-Point Analyzer A complete transportable natural gas dew-point analysis system for field spot-check measurements. Periodic online operation when located in a temperature maintained analyzer house. Measurements and functionality are instantly accessible through integrated alphanumeric display and touch-glass HMI interface including log of dew point readings for operator review. For more information, please contact your local Michell Instruments office, or visit our website www.michell.com. www.michell.com

Main Unit 245mm 9.65" 270mm 10.63" 4 off M12 (1/2") Clearance 355mm [13.9"] 290mm [11.41"] 318mm 12.52" Water Dew-Point Channel 1/4" NPT Female (CSA) 1/8" NPT Female (ATEX/IECEx) Hydrocarbon Dew-Point Channel Inlet 1/4" NPT Female (CSA) Inlet 1/8" NPT Female (ATEX/IECEx) Enclosure Breather 1/4" NPT Female (CSA) 1/8" NPT Female (ATEX/IECEx) Do NOT obscure Hydrocarbon Dew-Point Channel Outlet 1/4" NPT Female (CSA) Outlet 1/8" NPT Female (ATEX/IECEx) Water Dew-Point Channel Outlet 1/4" NPT Female (CSA) Outlet 1/8" NPT Female (ATEX/IECEx) 310mm [12.20"] Cable Entry Glands 3 off M20 (ATEX) 3 off 1/2" NPT (CSA) Sampling Systems Indoor Versions 316 Stainless Steel Panel Condumax II HC and water dew-point analyzer with sampling system for indoor installation. Outdoor Versions Stainless Steel Enclosure Condumax II HC and water dew-point analyzer within sampling system for outdoor installation. Options fitted in version shown: Enclosure cooling and heating. 750mm 30" 800mm 31" 758mm 30" 700mm 28" 475mm 19" 970mm 38" 1050mm 41" 1000mm 39" 475mm 19" General Note: Outline dimensions for HC dew point only versions are also the same as shown. Michell Instruments Ltd 48 Lancaster Way Business Park, Ely, Cambridgeshire, CB6 3NW Tel: +44 (0) 1353 658000, Fax: +44 (0) 1353 658199, Email: uk.info@michell.com, Web: www.michell.com/uk Michell Instruments adopts a continuous development programme which sometimes necessitates specification changes without notice. Issue no: Condumax II_97149_V9_UK_0317 2017 Michell Instruments