563C 12 SEER AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563C.18.5

Similar documents
563G (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 563G.18.1

563C (60 Hz) 12 SEER ELECTRIC AIR CONDITIONER. Sizes 024 thru 060. Form No. PDS 563C.24.11

Model PA10 ELECTRIC AIR CONDITIONER SS-PA10-06 FEATURES. coated for a long-lasting, rustresistant,

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner. Sizes 018 thru 060 FEATURES

661C 10 SEER HEAT PUMP UNIT. Sizes 018 thru 060. Form No. PDS 661C FEATURES

597C (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 597C.18.8

Product Data. 38ETG (60 Hz) 13 SEER Air Conditioner with Puron Refrigerant. Sizes 018 thru 060 FEATURES/BENEFITS

SPLIT-SYSTEM HEAT PUMP UNIT. Model PH12 SS-PH12-11 FEATURES

Product Data. 38BYG (60 Hz) 12 SEER Heat Pump. Sizes 018 thru 060 FEATURES/BENEFITS

Product Data PH13(N,P)R FEATURES AND BENEFITS. SPLIT SYSTEM HEAT PUMP For Use With R Refrigerant 1---1/2 TO 5 TONS ( )

10 SEER SPLIT-SYSTEM HEAT PUMP UNIT. Model PH10 SS-PH10-05 FEATURES

697C (60 HZ) Sizes 018 thru 060

550A (60 Hz) DELUXE 13 SEER AIR CONDITIONER WITH PURON (R-410A) Sizes 024 thru 060. Form No. PDS 550A.24.4

Product Data. 38BRC (60 Hz) Air Conditioner. Sizes 024 thru 060 FEATURES/BENEFITS

Product Data. 38EZG (60 Hz) Air Conditioner with Puron. Sizes 018 thru 060 FEATURES/BENEFITS

PAYNE. 710A (60 Hz) ELECTRIC AIR CONDITIONER. Sizes 018 thru 060. Form No. PDS 710A.18.3P. Heating & Cooling

Product Data. 38CKD (60 Hz) 13 SEER Air Conditioner Sizes FEATURES AND BENEFITS AVAILABLE SIZES:

Product Data PA13 AIR CONDITIONER 1 AND 3 PHASE 1-1/2-5 TONS ( ) FEATURES AND BENEFITS AVAILABLE SIZES:

652A DELUXE 12 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 018 thru 060. Form No. PDS 652A.18.3

Product Data. 38CKS (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 AVAILABLE OPTIONS

Product Data. 38CKC (60 Hz) 10 SEER Air Conditioner EXPORT MODELS. Sizes 018 thru 060 FEATURES

Model AA1B 10.0 SEER AIR CONDITIONER SS-AA1B-02. This document was created with FrameMaker FEATURES

Product Data. 38EYG (60 Hz) 12 SEER Heat Pump with Puron Refrigerant. Sizes 018 thru 060 FEATURES

Product Data. Performance 14 38TSA (60 Hz) Air Conditioner with Puron Refrigerant. Sizes 024 thru 060 FEATURES

Product Data. 38CKC 50 Hz Air Conditioner. Sizes 018 thru 060 FEATURES

Product Data PA13NA PA13PA FEATURES AND BENEFITS

Product Data. Performance 12 38YZA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 018 thru 060

Product Data. Performance 13 38YXA (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. 38TXA (60 Hz) Air Conditioner with Puron (R-410A) Sizes 024 thru 060

Product Data. Performance 14 38YSP (60 Hz) Heat Pump with Puron Refrigerant. Sizes 024 thru 060

Product Data. 38EYA (60Hz) 12 SEER Split-System Cube Heat Pump with Puron Refrigerant FEATURING PURON THE ENVIRONMENTALLY SOUND REFRIGERANT

Product Data. 24ABA3 Baset13 Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

UP TO 17.5 SEER / 13.5 EER / 9.5 HSPF HEAT PUMP ENVIRONMENTALLY BALANCED R- 410A REFRIGERANT 2 THRU 5 TONS SPLIT SYSTEM

Product Data. 38YCC (60 Hz) 10 SEER Heat Pump Export Model Sizes ( /2 to 5 Nominal Tons) FEATURES AND BENEFITS.

R4H4. Product Specifications

Product Data. 38YCC 50 Hz Heat Pump. Sizes 024 thru 060 FEATURES/BENEFITS

R4H4. Product Specifications

N4H4. Product Specifications 14 SEER HEAT PUMP. ENVIRONMENTALLY SOUND R 410A REFRIGERANT 1½ THRU 5 TONS SPLIT SYSTEM 208 / 230 Volt, 1 phase, 60 Hz

WCH5**4. Product Specifications

Product Data INDUSTRY LEADING FEATURES / BENEFITS MODEL 126B PREFERRED SERIES AIR CONDITIONER WITH PURON REFRIGERANT 1 1/2 TO 5 NOMINAL TONS

N4H4. Product Specifications

Nominal Capacity /2Ton 024 2Tons /2Tons 036 3Tons /2Tons 048 4Ton 060 5Ton

Product Data INDUSTRY LEADING FEATURES / BENEFITS. BH13NA SINGLE -STAGE HEAT PUMP WITH PURONr REFRIGERANT. Efficiency S S Reliability S

Product Data. 38EYX 50Hz Heat Pump With R---410a Refrigerant Single and Three Phase 2To5Tons FEATURES AND BENEFITS AVAILABLE SIZES:

650A (60 Hz) QUANTUM PLUS 13 SEER HEAT PUMP WITH PURON REFRIGERANT. Sizes 024 thru 060. Form No. PDS 650A.24.1

A 14 SEER Heat Pump with R---410A Refrigerant Series

R 410A Ducted Horizontal Air Conditioner

R 410A Ducted Horizontal Air Conditioner. Model Number Voltage Size (tons) Nominal Btu/hr Operating Weight lbs (kg) HC4A318AKA

Product Data. Efficiency. S S Reliability

Product Data INDUSTRY LEADING FEATURES / BENEFITS. 116B Legacyt Line 16 Air Conditioner with Puronr Refrigerant 1-1/2 to 5 Nominal Tons

N4A6. Product Specifications

Product Data. Efficiency

NH4H4. Product Specifications 14 SEER HORIZONTAL DISCHARGE HEAT PUMP FOR USE WITH DUCTED INDOOR UNIT

Product Data. 224ANS PREFERREDt SERIES HEAT PUMP WITH PURONr REFRIGERANT 1-1/2 TO 5 NOMINAL TONS INDUSTRY LEADING FEATURES / BENEFITS

Product Data. 24AHA4 Performance Series Air Conditioner with Puron Refrigerant 1-1/2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data. Efficiency

Product Data. 24ABC6 Comfortt16 Air Conditioner with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

Product Data INDUSTRY LEADING FEATURES / BENEFITS

Advance Product Data

Product Data. 38YXA (60Hz) Deluxe 13 SEER Split-System Heat Pump with Puron (R-410A) Refrigerant

FF1DNA, FF1DNE FAN COIL UNITS. Sizes 018, 024, 030. Form No. PDS FF1D.18.3 FEATURES FF1D

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. Efficiency

Product Data. 25HCB6 Performancet Stage Heat Pump with Puronr Refrigerant 2to5Tons INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. FF1DNA, FF1DNE Fan Coil Units. Sizes 018 thru 030 FEATURES/BENEFITS

2 shp 13 lc 1 36 t - 1 a

1-1/2 THRU 2-1/2 TONS SPLIT SYSTEM FWM Series

Installation Instructions

Product Data. Efficiency

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS MODELS: HF-07 FEATURES B-0703

HEATING & COOLING 38YCA Sizes 018 thru YCN Sizes 024 thru 048. Copyright 1994 Carrier Corporation

TECHNICAL GUIDE DESCRIPTION SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS. HA300, HB360, HB480 & HB thru 50 NOMINAL TONS (50 Hz)

Commercial High-Efficiency Condensing Units

Commercial High-Efficiency Condensing Units

TECHNICAL SPECIFICATIONS

TECHNICAL GUIDE. Description SPLIT-SYSTEM AIR-COOLED CONDENSING UNITS YD360, 480 & THRU 50 NOMINAL TONS YTG-B-0811

TECHNICAL SPECIFICATIONS

3 to 5 Tons. AIR CONDITIONERS 2scu13. Dry Charge Split System - 60 HZ PRODUCT SPECIFICATIONS. 2 scu 13 lc 1 36 t - 1 a MODEL NUMBER IDENTIFICATION

MERIT Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,500 to 59,000 Btuh AIR CONDITIONERS 13ACXN PRODUCT SPECIFICATIONS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: AC036X10(3,4) THRU 060 (3 THRU 5 NOMINAL TONS, 3 PH) DESCRIPTION

JS5BD-K(A,B) Series High Efficiency Air Conditioner 13+ SEER Residential System Ton Capacity

Product Data. 38QRR Performancet Series Heat Pump with Puronr Refrigerant /2 to 5 Nominal Tons INDUSTRY LEADING FEATURES / BENEFITS

TECHNICAL GUIDE LISTED. SPLIT-SYSTEM AIR CONDITIONERS 10 SEER R22 60Hz MODELS: H*BA-(T,W)036 THRU 076 (3 THRU 6.3 NOMINAL TONS, 3 PH) DESCRIPTION

Product Data. Model 113A Legacy-RNC Series Air Conditioner with Puronr INDUSTRY LEADING FEATURES / BENEFITS. Efficiency S S S Sound S Comfort S

DT5BD Series High Efficiency Heat Pumps 13+ SEER Residential System Ton Capacity

Product Data. CA13NA Base Series Air Conditioner with Puronr Refrigerant INDUSTRY LEADING FEATURES / BENEFITS.

Product Data. Efficiency

Advance Product Data

ELITE Series R-410A. SEER up to to 5 Tons Cooling Capacity - 17,800 to 60,000 Btuh AIR CONDITIONERS EL16XC1 PRODUCT SPECIFICATIONS

MIN. CCT. QTY RLA LRA HP FLA AMPACITY /1/ /3/

PAJ3. Product Specifications

Advance Product Data

DRY CHARGE UNITS. 1.5 to 5 Tons AIR CONDITIONERS LCS13DC PRODUCT SPECIFICATIONS L C S 13 DC MODEL NUMBER IDENTIFICATION

TECHNICAL GUIDE GENERAL SPECIFICATIONS COMMERCIAL SPLIT-SYSTEM COOLING UNITS FOUR PIPE SYSTEM OUTDOOR UNIT: INDOOR UNIT:

Product Data. S Up to 20.5 SEER / 15.5 EER S Microtube Technologyt refrigeration system S Indoor air quality accessories available Sound

SPLIT SYSTEM HEAT PUMP 1½ 5 TON HERITAGE 13 MODELS 2A6H A American Standard Heating & Air Conditioning

072, 090, 120, 180 & 240 MODELS C SERIES CONDENSING UNITS P SERIES HEAT PUMPS

Product Data. Split System Heat Pump B-EN. February A6H6024H1000A

Split System Heat Pump Product Data

TECHNICAL GUIDE MODELS: H5CE090, H3CE120 & H1CE /2, 10, & 12-1/2 NOMINAL TONS EER DESCRIPTION

Transcription:

12 SEER AIR CONDITIONER 563C Sizes 018 thru 060 Model 563C Energy-Efficient Air Conditioners incorporate innovative technology to provide quiet, reliable cooling performance. Built into these units are the features most desired by homeowners today including SEER ratings up to 14.0 when combined with specific Bryant equipment. All models are listed with UL (U.S. and Canada), ARI, and CEC. The 563C meets ENERGY STAR guidelines for energy efficiency. FEATURES UNIT DESIGN Copper tube, enhanced sine wave aluminum fin coil is designed for optimum heat transfer. Vertical air discharge carries sound and hot condenser air up and away from adjacent patio areas and foliage. Heat pump style base pan for easy removal of water, dirt, and leaves. ELECTRICAL RANGE All units are offered in single phase 208/230v. WIDE RANGE OF SIZES Available in 7 nominal sizes from 018 through 060 to meet the needs of residential and light commercial applications. COMPRESSOR This unit features the latest in reliable, efficient compressor technology. Each compressor is mounted on rubber isolators for additional sound reduction. The 563C compressors start under most system loads, minimizing the need for start assistance components. For improved serviceability, units are equipped with a compressor terminal plug. Continuous operation is approved down to 55 F (12.8 C) in the cooling mode. (See cooling performance tables.) Operation down to 0 F or 20 F is approved when low-ambient requirements are met. WEATHER-PROTECTIVE CABINET The access panels and top are protected with a galvanized coating, then treated with a layer of zinc phosphate to which a modified polyester powder coating is applied and baked on. This provides each unit with a hard, smooth finish that will last for many years. All screws on cabinet exterior are coated for a long-lasting, rustresistant, quality appearance. TOTALLY ENCLOSED FAN MOTOR Means greater reliability under adverse weather conditions and dependable performance for many years. The permanent-split-capacitor type motor was designed for optimum efficiency. The motor was tested and qualified under extreme conditions to ensure greatest reliability. APPLICATION VERSATILITY The 563C can be combined with a wide variety of evaporator coils and blower packages to provide quiet, dependable comfort. can be installed on a roof or at ground level on a slab. EXTERNAL SERVICE VALVES Both service valves are brass, front seating type with sweat connections. Valves are externally located so refrigerant tube connections can be made quickly and easily. Each valve has a service port for ease of checking operating refrigerant pressures. EASY SERVICEABILITY One access panel provides access to electrical controls and compressor. Removal of wire dome gives access to fan motor and removal of the top gives access to the coil. COMPRESSOR PROTECTION Includes a suction tube accumulator on 048 and 060 sizes that reduces the amount of liquid refrigerant reaching the compressor. All compressors are protected by internal temperature and current sensitive overloads. An internal pressure relief is provided for high-pressure protection to the refrigerant system. LIMITED WARRANTY Standard 5-year limited warranty on all parts and 5-year limited warranty on compressor. Form No. PDS 563C.18.5

DIMENSIONS M AIR IN AIR DISCHARGE A SQ AIR DISCHARGE AIR IN 3 /8-IN. DIA TIEDOWN KNOCKOUTS (2) PLACES N J K L AIR IN B FIELD POWER SUPPLY CONN 7 / 8-IN. DIA HOLE WITH 1 1 / 8-IN. DIA KNOCKOUT AND 1 3 / 8-IN. DIA KNOCKOUT FIELD CONTROL SUPPLY CONN 7 / 8-IN. DIA HOLE 3 / 8-IN. DIA LIQUID LINE CONN P AIR DISCHARGE E AIR IN F G H D DIA VAPOR LINE CONN 1 1 /4 2 7 /8 C NOTES: 1. Allow 30 in. clearance to service side of unit, 48 in. above unit, 6 in. on one side, 12 in. on remaining side, and 24 in. between units for proper airflow. 2. Minimum outdoor operating ambient in cooling mode is 55 F, max. 125 F. 3. Series designation is the 14th position of the unit model number. 4. Center of gravity. A97017 DIMENSIONS (IN.) MINIMUM MOUNTING UNIT SIZE SERIES A B C D E F G H J K L M N P PAD DIMENSIONS 018 B 22-1/2 29-15/16 3-3/16 5/8 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-1/4 9-1/2 11-1/2 22-1/2 x 22-1/2 018 C 22-1/2 31-15/16 3-3/16 5/8 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-1/4 9-1/2 11-1/2 22-1/2 x 22-1/2 024 D 22-1/2 31-15/16 3-3/16 5/8 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 14-3/4 14 10 22-1/2 x 22-1/2 024 E 22-1/2 31-15/16 3-3/16 5/8 3-11/16 18-1/8 19-3/4 22-1/4 14-3/8 19-9/16 22-1/16 10-1/4 9-1/2 11-1/2 22-1/2 x 22-1/2 030 C, D 30 27-15/16 3-3/16 3/4 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 14-3/4 14 11 30 x 30 036 E, F 30 27-15/16 3-3/16 3/4 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 14-3/4 14 11 30 x 30 042 E, F 30 33-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 14-3/4 14 13 30 x 30 042 G 30 37-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 14-3/4 14 14 30 x 30 048 H 30 39-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14-3/4 15 30 x 30 060 G 30 39-15/16 3-1/4 7/8 6-1/2 23-1/2 27-1/4 29-3/4 20 27-1/16 29-9/16 15-1/2 14-3/4 15 30 x 30 2

RECOMMENDED TUBE DIAMETERS LIQUID TUBE DIAMETER (IN.) VAPOR TUBE DIAMETER (IN.) UNIT 0 to 50 Ft 0 to 50 Ft Long-Line Applications* SIZE Tube Length Long-Line Applications* Tube Length (Maximum Diameter) 018, 024 5/8 3/4 030, 036 3/4 7/8 3/8 3/8 042, 048 7/8 1-1/8 060 1-1/8 1-1/8 * For tube sets greater than 50 ft. horizontal or 20 ft. vertical differential, consult Residential s Split Long-Line Application Guideline. CHECK-FLO-RATER PISTON CHART PISTON* UNIT SIZE-SERIES IDENTIFICATION NO. 018-B 52 018-C 55 024-D 61 024-E 63 030-C, D 70 036-E 73 036-F 76 042- E, F, G 82 048-H 88 060-G 104 * Piston listed is for any approved coil non-capillary tube combination. Piston is shipped with outdoor unit and must be installed in an approved indoor coil. CHARGING SUBCOOLING (TXV-TYPE EXANSION DEVICE) UNIT SIZE-SERIES REQUIRED SUBCOOLING ( F). 018-B 9 018-C 10 024-D 13 024-E 10 030-C 11 030-D 10 036-E 14 036-F 10 042-E, G 12 042-F 10 048-H 11 060-G 11 MODEL NUMBER NOMENCLATURE 563C N X 018 000 A A AA Model 12 SEER Split Air Conditioner Electrical Supply N 208/230-1-60 Nominal 018 1.5 ton 042 3.5 ton 024 2 ton 048 4 ton 030 2.5 ton 060 5 ton 036 3 ton N/A Standard Series A Original Series B Second Series Common U.S.A. Only Heating Size UNITARY AIR CONDITIONING MANUFACTURER CERTIFIED TO ARI AS COMPLYING WITH ARI EQUIPMENT STANDARD 210 CERTIFICATION APPLIES ONLY WHEN THE COMPLETE SYSTEM IS LISTED WITH ARI. * As an ENERGY STAR Partner, Bryant Heating & s has determined that this product meets the ENERGY STAR guidelines for energy efficiency. REGISTERED QUALITY SYSTEM Refer to the combination ratings in the Product Data Sheet for system combinations meeting ENERGY STAR efficiency standards. * 3

See notes on page 5. SPECIFICATIONS UNIT SIZE-SERIES 018-B/C 024-D/E 030-C/D 036-E/F 042-E, G/F Operating Weight (Lb) 133 147 161 169 180/186 ELECTRICAL Volts Hertz Phase 208/230 60 1 Operating Voltage Range* 187 253 Compressor Rated Load Amps 9.0/7.7 10.9 15.0/12.2 16.0/15.1 20.0/17.9 Locked Rotor Amps 41.0 54.0/55.0.5/.0 88.0/78.0 104.0/86.0 Condenser Fan Motor Full Load Amps 0.5 0.75 0.8 1.1 1.1 Min Ampacity for Wire Sizing 11.8/10.2 14.4 19.6/16.1 21.1/20.0 26.1/23.5 Min Wire Size (60 C Copper) AWG 14 14 14 12 10/12 Min Wire Size (75 C Copper) AWG 14 14 14 12 10/12 Max Wire Length (Ft) (60 C Copper) 66/ 53 39/46 /63 74/52 Max Wire Length (Ft) (75 C Copper) /68 50 37/44 54/60 70/50 Max Branch Circuit Fuse Size** 20/15 25/20 30/25 30 40 COMPRESSOR AND REFRIGERANT Compressor Type Scroll/Reciprocating Temperature and Current Protection Internal Line Break Refrigerant Type R-22 Amount (Lb) 5.0 5.25 6.25/6.5 6.50/6.75 6.75, 7.25/6.75 CONDENSER COIL AND FAN Coil Face Area (Sq Ft) 10.8/11.6 11.6 14.8 14.8 18.5, 20.9/18.5 Fins per In. Rows Circuits 25 1 2 25 1 2 25 1 2 25 1 3 Fan Motor (PSC) HP and RPM 1/12 and 1100 1/10 and 1100 1/8 and 825 1/5 and 825 1/5 and 825 Volts Hertz Phase 208/230 60 1 Condenser Airflow (CFM) 1700 2000 2500/2400 2800 2800 OPTIONAL EQUIPMENT Coastal Filter KAACF1001MED KAACF1101LRG Time-Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater KAACH1201AAA/KAACH1001AAA Inlet Grille Kit KSABG1004CSM/KSABG1104CSM KSABG1104CSM KSABG1704CMD KSABG2004CMD, KSABG2204CMD/ KSABG2004CMD Start Assist Capacitor/Relay Type KSAHS1501AAA/KSAHS2001AAA KSAHS1501AAA/KSAHS0901AAA Start Assist PTC Type KAACS0201PTC Sound Hood KSASH1801COP/KSASH2001BRL KSASH0601COP/KSASH2001BRL TXV (RPB) KAATX0201RPB KAATX0301RPB KAATX0401RPB KAATX0501RPB TXV (Hard Shutoff) KSATX0601HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier P502-8083S (RCD) P502-8163S (RCD) Evaporator Freeze Thermostat KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control KAAWS0101AAA Low-Ambient Pressure Switch KSALA0201R22 MotorMaster Low-Ambient Controller*** KSALA0401AAA Ball Bearing Fan Motor HC34GE232 (RCD) HC38GE231 (RCD) Thermidistat TM Control Programmable/Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B Thermostat Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B Thermostat Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBNAC01-B Builder s Thermostat Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Builder s Thermostat TSTATXXBBP01 Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit (4 to 5 wire) 10 Pack TSTATXXCNV10 4

SPECIFICATIONS Continued UNIT SIZE-SERIES 048-H 060-G Operating Weight (Lb) 237 260 ELECTRICAL Volts Hertz Phase 208/230 60 1 208/230 60 1 Operating Voltage Range* 187 253 Compressor Rated Load Amps 19.2 28.8 Locked Rotor Amps 137.0 148.0 Condenser Fan Motor Full Load Amps 1.4 1.4 Min Ampacity for Wire Sizing 25.4 37.4 Min Wire Size (60 C Copper) AWG 10 8 Min Wire Size (75 C Copper) AWG 10 8 Max Wire Length (Ft) (60 C Copper) 77 82 Max Wire Length (Ft) (75 C Copper) 73 78 Max Branch Circuit Fuse Size** 40 60 COMPRESSOR AND REFRIGERANT Compressor Type Scroll Temperature and Current Protection Internal Line Break Refrigerant Type R-22 Amount (Lb) 8.80 12.88 CONDENSER COIL AND FAN Coil Face Area (Sq Ft) 22.2 22.4 Fins per In. Rows Circuits 20 2 5/25 1 4 23 2 6 Fan Motor (PSC) HP and RPM 1/4 and 1125 1/4 and 1125 Volts Hertz Phase 208/230 60 1 Condenser Airflow (CFM) 3300 OPTIONAL EQUIPMENT Coastal Filter KAACF1101LRG Time-Delay Relay KAATD0101TDR Cycle Protector KSACY0101AAA Crankcase Heater Standard Inlet Grille Kit KSABG2304CMD Start Assist Capacitor/Relay Type KSAHS1501AAA KSAHS1601AAA Start Assist PTC Type KAACS0201PTC Sound Hood KSASH0601COP KSASH2101COP TXV (RPB) KAATX0601RPB KAATX0701RPB TXV (Hard Shutoff) KSATX0701HSO KSATX1001HSO Low-Pressure Switch KAALP0101LPS High-Pressure Switch KSAHI0101HPS Filter Drier Standard Evaporator Freeze Thermostat KAAFT0101AAA Liquid-Line Solenoid Valve KAALS0101LLS Winter Start Control KAAWS0101AAA Low-Ambient Pressure Switch KSALA0201R22 MotorMaster Low-Ambient Controller*** KSALA0401AAA Ball Bearing Fan Motor HC40GE232(RCD) Thermidistat TM Control Programmable/Non-Programmable Thermostat with Humidity Control TSTATBBPRH01-B Thermostat Auto Changeover, 7-Day Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBPAC01-B Thermostat Auto Changeover, Non-Programmable, F/ C, 1-Stage Heat,1-Stage Cool TSTATBBNAC01-B Builder s Thermostat Manual Changeover, Non-Programmable, F/ C, 1-Stage Heat, 1-Stage Cool TSTATBBBAC01-B Outdoor Air Temperature Sensor TSTATXXSEN01-B Backplate for Builder s Thermostat TSTATXXBBP01 Backplate for Non-Programmable Thermostat TSTATXXNBP01 Backplate for Programmable Thermostat TSTATXXPBP01 Thermostat Conversion Kit (4 to 5 wire) 10 Pack TSTATXXCNV10 *Permissible limits of the voltage range at which unit will operate satisfactorily. Operation outside these limits may result in unit failure. If wire is applied at ambient greater than 30 C (86 F), consult Table 310-16 of the NEC (ANSI/NFPA 70). The ampacity of nonmetallic-sheathed cable (NM), trade name ROMEX, shall be that of 60 C (140 F) conductors, per the NEC (ANSI/NFPA 70) Article 336-26. Length shown is as measured 1 way along wire path between unit and service panel for voltage drop not to exceed 2%. ** Time-delay fuse or circuit breaker. Charge quantity is for 15 ft of interconnecting tubing. For tubing lengths longer than 15 ft, add 0.6 oz. of refrigerant per ft of tube length in excess of 15 ft. Start assist capacitor and relay required when using liquid solenoid valve or hard shutoff TXV (except 048 and 060). Do not use hard shutoff TXV with liquid solenoid valve. *** Fan motor with ball bearings required. N/A Not applicable in this application. NOTES: All motors/compressors contain internal overload protection. Copper wire must be used from service disconnect to unit. Control circuit is 24v on all units and requires external power source. 5

USAGE GUIDELINE REQUIRED FOR LOW-AMBIENT APPLICATIONS (Below 55 F) REQUIRED FOR LONG-LINE APPLICATIONS* (Over 50 Ft) REQUIRED FOR SEA COAST APPLICATIONS (Within 2 Miles) Crankcase Heater Yes Yes No Evaporator Freeze Thermostat Yes No No Winter Start Control Yes No No Accumulator No No No Compressor Start Assist Capacitor and Relay Yes Yes No MotorMaster Low-Ambient Controller or Yes No No Low-Ambient Pressure Switch Wind Baffle See Low-Ambient Instructions No No Coastal Filter No No Yes Liquid-Line Solenoid Valve or Hard Shutoff TXV No See Long-Line Application Guideline Ball Bearing Fan Motor Yes No No * For tubing line sets greater than 50 ft horizontal or 20 ft vertical differential, refer to Residential s Split s Long-Line Application Guideline. Only when low-pressure switch is used. Required for low-ambient controller (full modulation feature) and MotorMaster Control only. No DESCRIPTION AND USAGE (Listed Alphabetically) 1. Ball-Bearing Fan Motor A fan motor with ball bearings, which permits speed reduction while maintaining bearing lubrication. Usage Guideline: Required on all units when MotorMaster Low-Ambient Controller is installed. 2. Coastal Filter A mesh screen inserted under the top cover and inside the base pan to protect the condenser coil from salt damage without restricting airflow. 3. Compressor Start Assist Capacitor and Relay Start capacitor and relay gives a "hard" boost to compressor motor at each start up. Usage Guideline: Required for single-phase reciprocating compressors in the following applications: Long line Low ambient Hard shut off expansion valve on indoor coil Liquid line solenoid on indoor coil Required for single-phase scroll compressors in the following applications: Long line Low ambient Suggested for all compressors in areas with a history of low voltage problems. 4. Compressor Start Assist PTC Type Solid-state electrical device which gives a "soft" boost to the single-phase compressor motor at each start up. Usage Guideline: Suggested when compressor power supply is marginal Suggested in reciprocating single-phase compressor applications with rapid pressure balance (RPB) expansion valve on indoor coil. 5. Crankcase Heater An electric resistance heater which mounts to the base of the compressor to keep the lubricant warm during off cycles. Improves compressor lubrication on restart and minimizes the chance of liquid slugging. Usage Guideline: Required in low ambient applications. Required in long line applications. Suggested in all commercial applications. 6. Cycle Protector Solid-state timing device which prevents compressor rapid recycling. Control provides an approximate 5-minute delay after power to the compressor has been interrupted for any reason, including normal room thermostat cycling. Usage Guideline: Installations in areas where power interrruptions are frequent. Where user is likely to play with the room thermostat. All commercial installations. Installations where interconnecting tube length exceeds 50 ft. High-rise applications. 7. Evaporator Freeze Thermostat An SPST temperature-actuated switch that stops unit operation when evaporator reaches freeze-up conditions. Usage Guideline: Required when low ambient kit has been added. 8. Filter Drier A device for removing contaminants from refrigerant circulating in an air conditioning system: single-direction flow. Usage Guideline: Suggested in all field-connected split-system air conditioners. 9. High-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on high side of refrigerant circuit. Cycles compressor off if refrigerant pressure rises to 426 ± 10 psig and resets at 320 ± 20 psig. Provides protection against compressor damage due to loss of outdoor airflow. Usage Guideline: Suggested in installations exposed to "very dirty" outdoor air. Suggested in installations where condenser inlet air temperature exceeds 125 F (51.7 C). 6

DESCRIPTION AND USAGE (continued) 10. Liquid-Line Solenoid Valve (LLS) This device serves two purposes. It is an electrically operated shutoff valve which stops and starts refrigerant liquid flow in response to compressor operation. It maintains a column of refrigerant liquid ready for action at next compressor operation cycle. It also provides system protection against off-cycle refrigerant migration. NOTE: When LLS is used with reciprocating compressors, Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Required in air conditioner long line applications with a piston indoor metering device to prevent off cycle refrigerant migration. A hard shut off TXV can be used instead of LLS in single flow air conditioner applications. See Long Line Application Guideline. 11. Low-Ambient Pressure Switch A long life pressure switch which is mounted to outdoor unit service valve. It is designed to cycle the outdoor fan motor in order to maintain head pressure within normal operating limits (approximately 100 psig to 225 psig). The control will maintain working head pressure at low-ambient temperatures down to 0 F ( 17.8 C) when properly installed. Usage Guideline: A Low-Ambient Pressure Switch or MotorMaster Low-Ambient Controller must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). 12. Low-Pressure Switch Auto reset SPST switch activated by refrigerant pressure on low side of refrigerant circuit. Cycles compressor off if refrigerant pressure drops to about 27 psig. Prevents indoor coil freeze-up due to loss of indoor airflow. Provides additional protection against compressor damage due to loss of refrigerant charge. To prevent rapid compressor recycling, Cycle Protector can be used with this switch. Usage Guideline: Where indoor coil is exposed to dirty air. All commercial installations. 13. MotorMaster -Low-Ambient Controller A fan speed control device activated by a temperature sensor, designed to control condenser fan motor speed in response to the saturated, condensing temperature during operation in cooling mode only. For outdoor temperatures down to 20 F ( 28.9 C), it maintains condensing temperature at 100 F ± 10 F (37.8 C ± 12 C). Usage Guideline: A MotorMaster Low-Ambient Controller or Low-Ambient Pressure Switch must be used when cooling operation is used at outdoor temperatures below 55 F (12.8 C). Suggested for all commercial applications. 14. Outdoor Air Temperature Sensor Designed for use with Bryant Thermostats listed in this publication. The device enables the thermostat to display the outdoor temperature. This device also is required to enable special thermostat features such as auxiliary heat lock out. Usage Guideline: Suggested for all Bryant thermostats listed in this publication. 15. Sound Hood Wraparound sound reducing cover for the compressor. Reduces the sound level by about 2 dba. Usage Guideline: Suggested when unit is installed closer than 15 ft to quiet areas bedrooms, etc. Suggested when unit is installed between two houses less than 10 ft apart. 16. Thermostatic Expansion Valve (TXV) Single-Flow A modulating flow-control valve which meters refrigerant liquid flow rate into the evaporator in response to the superheat of the refrigerant gas leaving the evaporator. Kit includes valve, adapter tubes, and external equalizer tube. Both hard shutoff and RPB valves are available. NOTE: When using a hard shut off TXV with single phase reciprocating compressors, a Compressor Start Assist Capacitor and Relay is required. Usage Guideline: Required to achieve ARI ratings in certain equipment combinations. Refer to combination ratings. Hard shut off TXV or LLS required in air conditioner long line applications. Required for use on all zoning systems. 17. Time-Delay Relay An SPST delay relay which briefly continues operation of indoor blower motor to provide additional cooling after the compressor cycles off. NOTE: Most indoor unit controls include this feature. For those that do not, use the guideline below. Usage Guideline: For improved efficiency ratings for certain combinations of indoor and outdoor units. Refer to ARI ary Directory. 18. Winter Start Control An SPST delay relay which bypasses the Low-Pressure Switch for approximately 3 minutes to permit start-up for cooling operation under low load conditions. Usage Guideline: All air conditioners to which Low-Pressure Switch and Low-Ambient Controller have been added. NOTE: Tested in accordance with ARI standard 270.95. (Not listed with ARI.) A-WTD. SOUND POWER (dba) UNIT STANDARD TYPICAL OCTAVE BAND SPECTRUM (without tone adjustment) SIZE RATING 125 250 500 1000 2000 4000 8000 018B 76 48.0 60.0.0 68.5.0 59.5 53.5 018C 76 51.5 59.5 64.5 69.0 70.5 60.0 58.0 024D 76 55.0 61.0 66.5 71.5 68.0 64.0 59.0 024E 76 55.5.5 68.0 70.0.0 61.5.5 030C 78 54.0 61.0 66.0 70.5 66.0.5 58.0 030D 78 50.0.0 68.0.5 70.0 61.5 58.5 036E 80 53.5 68.5.5 74.0 70.0 65.0 59.5 036F 80 54.0 66.5 70.0 71.0 69.0.0 60.5 042E, G 80 54.0 61.0.5 73.5 71.0 63.5 58.5 042F 80 53.5 66.0 70.5 75.0 69.0 65.0.5 048H 80 54.0 64.5.5.5 70.0.5 63.5 060G 80 58.0 65.0 69.5 75.5 74.0 71.5 65.0 7

COMBINATION RATINGS UNIT SIZE-SERIES 018-B, C 024-D, E See notes on page 19. INDOOR MODEL TOT. CAP BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER BRYANT GAS FURNACE OR TDR TXV *CC5A/CD5AA018 17,000 NONE 12.00 12.00 11.25 CC5A/CD5AA024 17,600 NONE 12.00 12.00 11.50 CC5A/CD5AW024 17,600 NONE 12.00 12.00 11.45 CE3AA024 17,600 NONE 12.00 12.00 11.55 CF5AA024 17,600 NONE 12.00 12.00 11.50 CK3BA024 17,600 NONE 12.00 12.00 11.70 CK5A/CK5BA018 17,000 NONE 12.00 12.00 11.40 CK5A/CK5BA024 17,600 NONE 12.00 12.00 11.70 CK5A/CK5BW024 17,600 NONE 12.00 12.00 11.70 F(A,B)4BN(F,C)018 17,000 TDR 12.00 12.00 11.35 F(A,B)4BN(F,C)024 17,600 TDR 12.50 12.50 11.80 FC4CNF024 17,600 TDR&TXV 12.50 11.75 FF1DNA018 17,000 TDR 12.00 12.00 11.70 FF1DNA024 17,600 TDR 12.50 12.50 11.65 FF1DNE018 17,000 TDR&TXV 12.00 11.50 FF1DNE024 17,600 TDR&TXV 12.50 11.65 FG3AAA024 17,600 NONE 12.00 12.00 11.45 FK4DNF001 17,800 TDR&TXV 13.50 13.05 FK4DNF002 18,000 TDR&TXV 14.00 13.30 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA018 17,000 TDR 13.50 13.50 12.35 CC5A/CD5AA024 17,600 TDR 13.50 13.50 12.65 CC5A/CD5AW024 17,600 TDR 13.50 13.50 12.70 CE3AA024 17,600 TDR 13.50 13.50 12.70 CK3BA024 17,600 TDR 13.50 13.50 13.00 CK5A/CK5BA018 17,000 TDR 13.50 13.50 12.60 CK5A/CK5BA024 17,600 TDR 13.50 13.50 12.90 CK5A/CK5BW024 17,600 TDR 13.50 13.50 12.90 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA018 17,000 TDR 13.50 13.50 12.40 CC5A/CD5AA024 17,600 TDR 13.50 13.50 12.70 CC5A/CD5AW024 17,600 TDR 13.50 13.50 12.75 CE3AA024 17,600 TDR 13.50 13.50 12.75 CK3BA024 17,600 TDR 13.50 13.50 13.05 CK5A/CK5BA018 17,000 TDR 13.50 13.50 12.65 CK5A/CK5BA024 17,600 TDR 13.50 13.50 12.95 CK5A/CK5BW024 17,600 TDR 13.50 13.50 12.95 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CE3AA024 17,600 TDR 13.50 13.50 12.70 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA018 17,000 TDR 13.50 13.50 12.40 CC5A/CD5AA024 17,600 TDR 13.50 13.50 12.65 CC5A/CD5AW024 17,600 TDR 13.50 13.50 12.70 CE3AA024 17,600 TDR 13.50 13.50 12.70 CK3BA024 17,600 TDR 13.50 13.50 13.00 CK5A/CK5BA018 17,000 TDR 13.50 13.50 12.60 CK5A/CK5BA024 17,600 TDR 13.50 13.50 12.90 CK5A/CK5BW024 17,600 TDR 13.50 13.50 12.90 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AW024 17,600 TDR 13.50 13.50 12.70 CE3AA024 17,600 TDR 13.50 13.50 12.70 CK3BA024 17,600 TDR 13.50 13.50 13.00 CK5A/CK5BW024 17,600 TDR 13.50 13.50 12.90 *CC5A/CD5AA024 23,000 NONE 12.00 12.00 11.15 CC5A/CD5AA030 23,400 NONE 12.00 12.00 11.15 CC5A/CD5AW024 23,000 NONE 12.00 12.00 11.15 CC5A/CD5AW030 23,400 NONE 12.00 12.00 11.15 CE3AA024 23,000 NONE 12.00 12.00 11.25 CE3AA030 23,400 NONE 12.00 12.00 11.35 CF5AA024 23,000 NONE 12.00 12.00 11.15 CK3BA024 23,000 NONE 12.00 12.00 11.30 CK3BA030 23,400 NONE 12.00 12.00 11.25 CK5A/CK5BA024 23,000 NONE 12.00 12.00 11.30 CK5A/CK5BA030 23,400 NONE 12.00 12.00 11.25 CK5A/CK5BW024 23,000 NONE 12.00 12.00 11.30 CK5A/CK5BW030 23,400 NONE 12.00 12.00 11.25 F(A,B)4BN(F,C)024 23,200 TDR 12.00 12.00 11.40 F(A,B)4BN(F,C)030 23,600 TDR 12.50 12.50 11.50 FC4CNF024 23,200 TDR&TXV 12.00 11.25 FC4CNF030 23,600 TDR&TXV 12.50 11.45 FF1DNA024 23,200 TDR 12.00 12.00 11.15 FF1DNA030 23,600 TDR 12.00 12.00 11.35 FF1DNE024 23,200 TDR&TXV 12.00 11.05 FF1DNE030 23,600 TDR&TXV 12.00 11.30 FG3AAA024 23,000 NONE 12.00 12.00 11.05 FK4DNF001 23,600 TDR&TXV 13.00 12.50 FK4DNF002 23,800 TDR&TXV 13.50 12.75 FK4DNF003 24,000 TDR&TXV 14.00 12.85 EER 8

COMBINATION RATINGS Continued UNIT SIZE-SERIES 024-D, E See notes on page 19. INDOOR MODEL TOT. CAP BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA024 23,000 TDR 13.50 13.50 12.15 CC5A/CD5AA030 23,200 TDR 13.50 13.50 12.30 CC5A/CD5AW024 23,000 TDR 13.50 13.50 12.25 CC5A/CD5AW030 23,200 TDR 13.50 13.50 12.30 CE3AA024 23,000 TDR 13.50 13.50 12.20 CE3AA030 23,200 TDR 13.50 13.50 12.45 CK3BA024 23,000 TDR 13.50 13.50 12.50 CK3BA030 23,200 TDR 13.50 13.50 12.45 CK5A/CK5BA024 23,000 TDR 13.50 13.50 12.35 CK5A/CK5BA030 23,200 TDR 13.50 13.50 12.35 CK5A/CK5BW024 23,000 TDR 13.50 13.50 12.35 CK5A/CK5BW030 23,200 TDR 13.50 13.50 12.40 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA024 23,000 TDR 13.50 13.50 12.25 CC5A/CD5AA030 23,200 TDR 13.50 13.50 12.45 CC5A/CD5AW024 23,000 TDR 13.50 13.50 12.35 CC5A/CD5AW030 23,200 TDR 13.50 13.50 12.40 CE3AA024 23,000 TDR 13.50 13.50 12.30 CE3AA030 23,200 TDR 13.50 13.50 12.55 CK3BA024 23,000 TDR 13.50 13.50 12.60 CK3BA030 23,200 TDR 13.50 13.50 12.55 CK5A/CK5BA024 23,000 TDR 13.50 13.50 12.45 CK5A/CK5BA030 23,200 TDR 13.50 13.50 12.45 CK5A/CK5BW024 23,000 TDR 13.50 13.50 12.45 CK5A/CK5BW030 23,200 TDR 13.50 13.50 12.50 COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AW024 23,000 TDR 13.50 13.50 12.25 CC5A/CD5AW030 23,200 TDR 13.50 13.50 12.35 CE3AA024 23,000 TDR 13.50 13.50 12.20 CE3AA030 23,200 TDR 13.50 13.50 12.50 CK3BA024 23,000 TDR 13.50 13.50 12.55 CK3BA030 23,200 TDR 13.50 13.50 12.50 CK5A/CK5BW024 23,000 TDR 13.50 13.50 12.35 CK5A/CK5BW030 23,200 TDR 13.50 13.50 12.40 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CE3AA024 23,000 TDR 13.50 13.50 12.25 CE3AA030 23,200 TDR 13.50 13.50 12.50 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CE3AA024 23,000 TDR 13.50 13.50 12.25 CE3AA030 23,200 TDR 13.50 13.50 12.55 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CE3AA024 23,200 TDR 13.50 13.50 12.20 CE3AA030 23,200 TDR 13.50 13.50 12.45 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA024 23,000 TDR 13.50 13.50 12.20 CC5A/CD5AA030 23,200 TDR 13.50 13.50 12.35 CC5A/CD5AW024 23,000 TDR 13.50 13.50 12.25 CC5A/CD5AW030 23,200 TDR 13.50 13.50 12.35 CE3AA024 23,000 TDR 13.50 13.50 12.25 CE3AA030 23,200 TDR 13.50 13.50 12.50 CK3BA024 23,000 TDR 13.50 13.50 12.55 CK3BA030 23,200 TDR 13.50 13.50 12.50 CK5A/CK5BA024 23,200 TDR 13.50 13.50 12.40 CK5A/CK5BA030 23,200 TDR 13.50 13.50 12.35 CK5A/CK5BW024 23,000 TDR 13.50 13.50 12.40 CK5A/CK5BW030 23,200 TDR 13.50 13.50 12.40 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AW024 23,000 TDR 13.50 13.50 12.20 CC5A/CD5AW030 23,200 TDR 13.50 13.50 12.30 CE3AA024 23,000 TDR 13.50 13.50 12.20 CE3AA030 23,200 TDR 13.50 13.50 12.45 CK3BA024 23,000 TDR 13.50 13.50 12.50 CK3BA030 23,200 TDR 13.50 13.50 12.45 CK5A/CK5BW024 23,000 TDR 13.50 13.50 12.35 CK5A/CK5BW030 23,200 TDR 13.50 13.50 12.40 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AW024 23,000 TDR 13.50 13.50 12.25 CC5A/CD5AW030 23,200 TDR 13.50 13.50 12.35 CE3AA024 23,000 TDR 13.50 13.50 12.20 CE3AA030 23,200 TDR 13.50 13.50 12.45 CK3BA024 23,000 TDR 13.50 13.50 12.50 CK3BA030 23,200 TDR 13.50 13.50 12.45 CK5A/CK5BW024 23,000 TDR 13.50 13.50 12.35 CK5A/CK5BW030 23,200 TDR 13.50 13.50 12.40 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AW024 23,000 TDR 13.50 13.50 12.25 CC5A/CD5AW030 23,200 TDR 13.50 13.50 12.35 CE3AA024 23,000 TDR 13.50 13.50 12.30 SEER BRYANT GAS FURNACE OR TDR TXV EER 9

COMBINATION RATINGS Continued UNIT SIZE-SERIES 024-D, E 030-C, D See notes on page 19. INDOOR MODEL TOT. CAP BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING CE3AA030 23,200 TDR 13.50 13.50 12.50 CK3BA024 23,000 TDR 13.50 13.50 12.55 CK3BA030 23,200 TDR 13.50 13.50 12.50 CK5A/CK5BW024 23,000 TDR 13.50 13.50 12.40 CK5A/CK5BW030 23,200 TDR 13.50 13.50 12.40 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CE3AA024 23,000 TDR 13.50 13.50 12.15 CE3AA030 23,200 TDR 13.50 13.50 12.45 *CC5A/CD5AA030 29,000 NONE 12.00 12.00 11.15 CC5A/CD5AA036 29,600 NONE 12.00 12.00 11.45 CC5A/CD5AW030 29,000 NONE 12.00 12.00 11.15 CC5A/CD5AW036 29,600 NONE 12.00 12.00 11.45 CE3AA030 29,000 NONE 12.00 12.00 11.30 CE3AA036 29,600 NONE 12.00 12.00 11.35 CF5AA036 29,600 NONE 12.00 12.00 11.40 CK3BA030 29,000 NONE 12.00 12.00 11.20 CK3BA036 29,600 NONE 12.00 12.00 11.45 CK5A/CK5BA030 29,000 NONE 12.00 12.00 11.20 CK5A/CK5BA036 29,600 NONE 12.00 12.00 11.45 CK5A/CK5BT036 29,600 NONE 12.00 12.00 11.45 CK5A/CK5BW030 29,000 NONE 12.00 12.00 11.20 CK5A/CK5BW036 29,600 NONE 12.00 12.00 11.50 F(A,B)4BN(F,C)030 29,200 TDR 12.00 12.00 11.40 F(A,B)4BN(F,C)036 29,600 TDR 12.00 12.00 11.20 FC4CNF030 29,200 TDR&TXV 12.00 11.45 FC4CNF036 29,600 TDR&TXV 12.00 11.25 FF1DNA030 29,000 TDR 12.00 12.00 11.30 FF1DNE030 29,000 TDR&TXV 12.00 11.35 FG3AAA036 29,600 NONE 12.00 12.00 11.30 FK4DNF001 29,400 TDR&TXV 13.00 12.40 FK4DNF002 29,600 TDR&TXV 13.50 12.70 FK4DNF003 29,800 TDR&TXV 13.50 12.90 FK4DNF005 30,000 TDR&TXV 14.00 13.35 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA030 28,400 TDR 13.00 13.00 12.05 CC5A/CD5AA036 29,600 TDR 13.50 13.50 12.45 CC5A/CD5AW030 28,400 TDR 13.00 13.00 12.10 CE3AA030 28,400 TDR 13.00 13.00 12.20 CE3AA036 29,000 TDR 13.50 13.50 12.30 CK3BA030 28,400 TDR 13.00 13.00 12.20 CK3BA036 29,600 TDR 13.50 13.50 12.45 CK5A/CK5BA030 28,400 TDR 13.00 13.00 12.05 CK5A/CK5BA036 29,600 TDR 13.50 13.50 12.45 CK5A/CK5BT036 29,600 TDR 13.50 13.50 12.45 CK5A/CK5BW030 28,400 TDR 13.00 13.00 12.15 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA030 28,400 TDR 13.00 13.00 12.25 CC5A/CD5AA036 29,600 TDR 13.50 13.50 12.60 CC5A/CD5AW030 28,400 TDR 13.00 13.00 12.25 CC5A/CD5AW036 29,600 TDR 13.50 13.50 12.65 CE3AA030 28,400 TDR 13.00 13.00 12.40 CE3AA036 29,000 TDR 13.50 13.50 12.45 CK3BA030 28,400 TDR 13.00 13.00 12.40 CK3BA036 29,600 TDR 13.50 13.50 12.60 CK5A/CK5BA030 28,400 TDR 13.00 13.00 12.20 CK5A/CK5BA036 29,600 TDR 13.50 13.50 12.65 CK5A/CK5BT036 29,600 TDR 13.50 13.50 12.65 CK5A/CK5BW030 28,400 TDR 13.00 13.00 12.30 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.65 COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,600 TDR 13.50 13.50 12.60 CC5A/CD5AW030 28,400 TDR 13.00 13.00 12.20 CC5A/CD5AW036 29,600 TDR 13.50 13.50 12.65 CE3AA030 28,400 TDR 13.00 13.00 12.35 CE3AA036 29,000 TDR 13.50 13.50 12.45 CK3BA030 28,400 TDR 13.00 13.00 12.35 CK3BA036 29,600 TDR 13.50 13.50 12.60 CK5A/CK5BA036 29,600 TDR 13.50 13.50 12.60 CK5A/CK5BT036 29,600 TDR 13.50 13.50 12.60 CK5A/CK5BW030 28,400 TDR 13.00 13.00 12.30 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.65 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AW036 29,600 TDR 13.50 13.50 12.70 CE3AA030 28,400 TDR 13.00 13.00 12.40 CE3AA036 29,000 TDR 13.50 13.50 12.50 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.70 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AW036 29,600 TDR 13.50 13.50 12.75 CE3AA030 28,400 TDR 13.00 13.00 12.45 SEER BRYANT GAS FURNACE OR TDR TXV EER 10

COMBINATION RATINGS Continued UNIT SIZE-SERIES 030-C, D 036-E, F See notes on page 19. INDOOR MODEL TOT. CAP BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER BRYANT GAS FURNACE OR TDR TXV CE3AA036 29,000 TDR 13.50 13.50 12.50 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.75 COILS + 355MAV042040 VARIABLE-SPEED FURNACE CC5A/CD5AW036 29,600 TDR 13.50 13.50 12.45 CE3AA030 28,400 TDR 13.00 13.00 12.20 CE3AA036 29,000 TDR 13.50 13.50 12.30 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.50 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA030 28,400 TDR 13.00 13.00 12.10 CC5A/CD5AA036 29,600 TDR 13.50 13.50 12.50 CC5A/CD5AW030 28,400 TDR 13.00 13.00 12.10 CC5A/CD5AW036 29,600 TDR 13.50 13.50 12.55 CE3AA030 28,400 TDR 13.00 13.00 12.25 CE3AA036 29,000 TDR 13.50 13.50 12.35 CK3BA030 28,400 TDR 13.00 13.00 12.25 CK3BA036 29,600 TDR 13.50 13.50 12.50 CK5A/CK5BA030 28,400 TDR 13.00 13.00 12.10 CK5A/CK5BA036 29,600 TDR 13.50 13.50 12.50 CK5A/CK5BT036 29,600 TDR 13.50 13.50 12.50 CK5A/CK5BW030 28,400 TDR 13.00 13.00 12.20 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.55 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,600 TDR 13.50 13.50 12.45 CC5A/CD5AW030 28,400 TDR 13.00 13.00 12.10 CC5A/CD5AW036 29,600 TDR 13.50 13.50 12.50 CE3AA030 28,400 TDR 13.00 13.00 12.20 CE3AA036 29,000 TDR 13.50 13.50 12.30 CK3BA030 28,400 TDR 13.00 13.00 12.25 CK3BA036 29,600 TDR 13.50 13.50 12.45 CK5A/CK5BA036 29,600 TDR 13.50 13.50 12.45 CK5A/CK5BT036 29,600 TDR 13.50 13.50 12.45 CK5A/CK5BW030 28,400 TDR 13.00 13.00 12.15 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.50 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,600 TDR 13.50 13.50 12.50 CC5A/CD5AW030 28,400 TDR 13.00 13.00 12.10 CC5A/CD5AW036 29,600 TDR 13.50 13.50 12.50 CE3AA030 28,400 TDR 13.00 13.00 12.25 CE3AA036 29,000 TDR 13.50 13.50 12.35 CK3BA030 28,400 TDR 13.00 13.00 12.25 CK3BA036 29,600 TDR 13.50 13.50 12.50 CK5A/CK5BA036 29,600 TDR 13.50 13.50 12.50 CK5A/CK5BT036 29,600 TDR 13.50 13.50 12.50 CK5A/CK5BW030 28,400 TDR 13.00 13.00 12.20 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.55 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA036 29,600 TDR 13.50 13.50 12.55 CC5A/CD5AW030 28,400 TDR 13.00 13.00 12.20 CC5A/CD5AW036 29,600 TDR 13.50 13.50 12.60 CE3AA030 28,400 TDR 13.00 13.00 12.30 CE3AA036 29,000 TDR 13.50 13.50 12.40 CK3BA030 28,400 TDR 13.00 13.00 12.30 CK3BA036 29,600 TDR 13.50 13.50 12.55 CK5A/CK5BA036 29,600 TDR 13.50 13.50 12.55 CK5A/CK5BT036 29,600 TDR 13.50 13.50 12.55 CK5A/CK5BW030 28,400 TDR 13.00 13.00 12.25 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.60 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AW036 29,600 TDR 13.50 13.50 12.60 CE3AA030 28,400 TDR 13.00 13.00 12.35 CE3AA036 29,000 TDR 13.50 13.50 12.40 CK5A/CK5BW036 29,600 TDR 13.50 13.50 12.60 *CC5A/CD5AA036 35,000 NONE 12.00 12.00 11.05 CC5A/CD5AA042 35,000 NONE 12.00 12.00 11.05 CC5A/CD5AW036 35,000 NONE 12.00 12.00 11.05 CC5A/CD5AW042 35,000 NONE 12.00 12.00 10.95 CE3AA036 35,000 NONE 12.00 12.00 10.95 CE3AA042 35,400 NONE 12.00 12.00 11.10 CF5AA036 35,000 NONE 12.00 12.00 11.00 CK3BA036 35,000 NONE 12.00 12.00 11.05 CK3BA042 35,000 NONE 12.00 12.00 11.05 CK5A/CK5BA036 35,000 NONE 12.00 12.00 11.10 CK5A/CK5BA042 35,000 NONE 12.00 12.00 11.05 CK5A/CK5BE042 35,000 NONE 12.00 12.00 11.10 CK5A/CK5BT036 35,000 NONE 12.00 12.00 11.05 CK5A/CK5BT042 35,000 NONE 12.00 12.00 11.05 CK5A/CK5BW036 35,000 NONE 12.00 12.00 11.05 F(A,B)4BN(F,B,C)042 35,400 TDR 12.00 12.00 10.95 F(A,B)4BN(F,C)036 35,000 TDR 11.50 11.50 10.75 EER 11

COMBINATION RATINGS Continued UNIT SIZE-SERIES 036-E, F See notes on page 19. INDOOR MODEL TOT. CAP BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER BRYANT GAS FURNACE OR TDR TXV FC4CN(F,B)042 35,400 TDR&TXV 12.00 11.00 FC4CNF036 35,000 TDR&TXV 11.50 10.70 FG3AAA036 34,600 NONE 11.50 11.50 10.85 FK4DNB006 36,000 TDR&TXV 14.00 12.95 FK4DNF001 35,000 TDR&TXV 12.00 11.60 FK4DNF002 35,200 TDR&TXV 12.00 11.80 FK4DNF003 35,600 TDR&TXV 13.00 12.20 FK4DNF005 35,800 TDR&TXV 13.50 12.65 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.50 12.50 11.75 CE3AA036 34,400 TDR 12.50 12.50 11.60 CE3AA042 35,000 TDR 13.00 13.00 11.85 CK3BA036 35,000 TDR 12.50 12.50 11.75 CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.75 CK5A/CK5BE042 35,000 TDR 13.00 13.00 11.85 CK5A/CK5BT036 35,000 TDR 12.50 12.50 11.75 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.50 12.50 11.95 CC5A/CD5AA042 35,000 TDR 13.00 13.00 12.00 CC5A/CD5AW036 35,000 TDR 12.50 12.50 12.00 CE3AA036 34,400 TDR 12.50 12.50 11.80 CE3AA042 35,000 TDR 13.00 13.00 12.00 CK3BA036 35,000 TDR 12.50 12.50 11.95 CK3BA042 35,000 TDR 13.00 13.00 12.00 CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.95 CK5A/CK5BA042 35,000 TDR 13.00 13.00 12.00 CK5A/CK5BE042 35,000 TDR 13.00 13.00 12.05 CK5A/CK5BT036 35,000 TDR 12.50 12.50 11.95 CK5A/CK5BT042 35,000 TDR 13.00 13.00 12.00 CK5A/CK5BW036 35,000 TDR 12.50 12.50 12.00 COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.50 12.50 11.90 CC5A/CD5AA042 35,000 TDR 13.00 13.00 12.00 CC5A/CD5AW036 35,000 TDR 12.50 12.50 12.00 CC5A/CD5AW042 35,000 TDR 13.00 13.00 12.10 CE3AA036 34,400 TDR 12.50 12.50 11.75 CE3AA042 35,000 TDR 13.00 13.00 12.05 CK3BA036 35,000 TDR 12.50 12.50 11.95 CK3BA042 35,000 TDR 13.00 13.00 12.00 CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.90 CK5A/CK5BA042 35,000 TDR 13.00 13.00 12.00 CK5A/CK5BE042 35,000 TDR 13.00 13.00 12.10 CK5A/CK5BT036 35,000 TDR 12.50 12.50 11.95 CK5A/CK5BT042 35,000 TDR 13.00 13.00 12.00 CK5A/CK5BW036 35,000 TDR 12.50 12.50 12.00 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA042 35,000 TDR 13.00 13.00 12.10 CC5A/CD5AW036 35,000 TDR 12.50 12.50 12.05 CC5A/CD5AW042 35,000 TDR 13.00 13.00 12.15 CE3AA036 34,400 TDR 12.50 12.50 11.85 CE3AA042 35,000 TDR 13.00 13.00 12.10 CK3BA042 35,000 TDR 13.00 13.00 12.05 CK5A/CK5BA042 35,000 TDR 13.00 13.00 12.05 CK5A/CK5BT042 35,000 TDR 13.00 13.00 12.05 CK5A/CK5BW036 35,000 TDR 12.50 12.50 12.05 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CC5A/CD5AA042 35,000 TDR 13.00 13.00 12.20 CC5A/CD5AW036 35,000 TDR 12.50 12.50 12.15 CC5A/CD5AW042 35,000 TDR 13.00 13.00 12.30 CE3AA036 34,400 TDR 12.50 12.50 11.95 CE3AA042 35,000 TDR 13.00 13.00 12.20 CK3BA042 35,000 TDR 13.00 13.00 12.15 CK5A/CK5BA042 35,000 TDR 13.00 13.00 12.15 CK5A/CK5BT042 35,000 TDR 13.00 13.00 12.15 CK5A/CK5BW036 35,000 TDR 12.50 12.50 12.15 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.50 12.50 11.85 CC5A/CD5AA042 35,000 TDR 12.50 12.50 11.95 CC5A/CD5AW036 35,000 TDR 12.50 12.50 11.90 CE3AA036 34,400 TDR 12.50 12.50 11.70 CE3AA042 35,000 TDR 12.50 12.50 11.95 CK3BA036 35,000 TDR 12.50 12.50 11.85 CK3BA042 35,000 TDR 12.50 12.50 11.90 CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.85 CK5A/CK5BA042 35,000 TDR 12.50 12.50 11.90 CK5A/CK5BE042 35,000 TDR 12.50 12.50 12.00 CK5A/CK5BT036 35,000 TDR 12.50 12.50 11.85 CK5A/CK5BT042 35,000 TDR 12.50 12.50 11.90 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.90 EER 12

COMBINATION RATINGS Continued UNIT SIZE-SERIES 036-E, F 042-E, F See notes on page 19. INDOOR MODEL TOT. CAP BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER BRYANT GAS FURNACE OR TDR TXV COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.50 12.50 11.65 CC5A/CD5AA042 35,000 TDR 12.50 12.50 11.70 CC5A/CD5AW036 35,000 TDR 12.50 12.50 11.70 CC5A/CD5AW042 35,000 TDR 12.50 12.50 11.85 CE3AA036 34,400 TDR 12.50 12.50 11.50 CE3AA042 35,000 TDR 12.50 12.50 11.75 CK3BA036 35,000 TDR 12.50 12.50 11.65 CK3BA042 35,000 TDR 12.50 12.50 11.80 CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.65 CK5A/CK5BA042 35,000 TDR 12.50 12.50 11.80 CK5A/CK5BE042 35,000 TDR 12.50 12.50 11.75 CK5A/CK5BT036 35,000 TDR 12.50 12.50 11.65 CK5A/CK5BT042 35,000 TDR 12.50 12.50 11.80 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.70 COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.50 12.50 11.80 CC5A/CD5AA042 35,000 TDR 12.50 12.50 11.85 CC5A/CD5AW036 35,000 TDR 12.50 12.50 11.85 CC5A/CD5AW042 35,000 TDR 12.50 12.50 11.95 CE3AA036 34,400 TDR 12.50 12.50 11.70 CE3AA042 35,000 TDR 12.50 12.50 11.90 CK3BA036 35,000 TDR 12.50 12.50 11.80 CK3BA042 35,000 TDR 12.50 12.50 11.85 CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.80 CK5A/CK5BA042 35,000 TDR 12.50 12.50 11.85 CK5A/CK5BE042 35,000 TDR 12.50 12.50 11.95 CK5A/CK5BT036 35,000 TDR 12.50 12.50 11.80 CK5A/CK5BT042 35,000 TDR 12.50 12.50 11.85 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.85 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA036 35,000 TDR 12.50 12.50 11.85 CC5A/CD5AA042 35,000 TDR 13.00 13.00 11.90 CC5A/CD5AW036 35,000 TDR 12.50 12.50 11.90 CC5A/CD5AW042 35,000 TDR 13.00 13.00 12.00 CE3AA036 34,400 TDR 12.50 12.50 11.70 CE3AA042 35,000 TDR 13.00 13.00 11.95 CK3BA036 35,000 TDR 12.50 12.50 11.85 CK3BA042 35,000 TDR 13.00 13.00 11.90 CK5A/CK5BA036 35,000 TDR 12.50 12.50 11.85 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.90 CK5A/CK5BE042 35,000 TDR 13.00 13.00 12.00 CK5A/CK5BT036 35,000 TDR 12.50 12.50 11.85 CK5A/CK5BT042 35,000 TDR 13.00 13.00 11.90 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.90 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA042 35,000 TDR 13.00 13.00 11.95 CC5A/CD5AW036 35,000 TDR 12.50 12.50 11.95 CC5A/CD5AW042 35,000 TDR 13.00 13.00 12.05 CE3AA036 34,400 TDR 12.50 12.50 11.75 CE3AA042 35,000 TDR 13.00 13.00 12.00 CK3BA042 35,000 TDR 13.00 13.00 11.95 CK5A/CK5BA042 35,000 TDR 13.00 13.00 11.95 CK5A/CK5BT042 35,000 TDR 13.00 13.00 11.95 CK5A/CK5BW036 35,000 TDR 12.50 12.50 11.95 *CC5A/CD5AA042 40,000 NONE 12.00 12.00 10.75 CC5A/CD5AC048 40,000 NONE 12.00 12.00 10.60 CC5A/CD5AW042 40,000 NONE 12.00 12.00 10.60 CC5A/CD5AW048 40,500 NONE 12.00 12.00 10.75 CD5AA048 40,500 NONE 12.00 12.00 10.75 CE3AA042 40,000 NONE 12.00 12.00 10.80 CE3AA048 40,500 NONE 12.00 12.00 10.85 CF5AA048 40,500 NONE 12.00 12.00 10.80 CK3BA042 40,000 NONE 12.00 12.00 10.75 CK3BA048 40,500 NONE 12.00 12.00 10.80 CK5A/CK5BA042 40,000 NONE 12.00 12.00 10.75 CK5A/CK5BA048 40,500 NONE 12.00 12.00 10.80 CK5A/CK5BE042 40,000 NONE 12.00 12.00 10.80 CK5A/CK5BT042 40,000 NONE 12.00 12.00 10.75 CK5A/CK5BT048 40,500 NONE 12.00 12.00 10.80 CK5A/CK5BW048 40,500 NONE 12.00 12.00 10.80 F(A,B)4BN(F,B,C)042 40,000 TDR 12.00 12.00 10.60 F(A,B)4BN(F,B,C)048 40,500 TDR 12.00 12.00 10.75 FC4CN(F,B)042 40,000 TDR&TXV 12.00 10.60 FC4CN(F,B)048 40,500 TDR&TXV 12.00 10.70 FC4CNB054 42,000 TDR&TXV 12.50 11.40 FG3AAA048 40,500 NONE 12.00 12.00 10.70 FK4DNB006 42,000 TDR&TXV 14.00 12.40 FK4DNF003 41,000 TDR&TXV 13.00 11.65 FK4DNF005 41,500 TDR&TXV 13.50 12.10 EER 13

COMBINATION RATINGS Continued UNIT SIZE-SERIES 042-E, F See notes on page 19. INDOOR MODEL TOT. CAP BTUH FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER BRYANT GAS FURNACE OR TDR TXV COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 11.40 CC5A/CD5AC048 39,500 TDR 12.50 12.50 11.30 CD5AA048 40,500 TDR 13.00 13.00 11.50 CE3AA042 40,000 TDR 12.50 12.50 11.45 CE3AA048 40,500 TDR 13.00 13.00 11.50 CK3BA042 40,000 TDR 12.50 12.50 11.40 CK3BA048 40,500 TDR 13.00 13.00 11.55 CK5A/CK5BA042 40,000 TDR 12.50 12.50 11.40 CK5A/CK5BA048 40,500 TDR 13.00 13.00 11.55 CK5A/CK5BE042 40,000 TDR 12.50 12.50 11.45 CK5A/CK5BT042 40,000 TDR 12.50 12.50 11.40 CK5A/CK5BT048 40,500 TDR 13.00 13.00 11.55 COILS + 315(A,J)AV060110 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 11.40 CC5A/CD5AC048 39,500 TDR 12.50 12.50 11.30 CC5A/CD5AW042 39,500 TDR 12.50 12.50 11.50 CC5A/CD5AW048 40,000 TDR 13.00 13.00 11.55 CD5AA048 40,500 TDR 13.00 13.00 11.50 CE3AA042 40,000 TDR 12.50 12.50 11.45 CE3AA048 40,500 TDR 13.00 13.00 11.50 CK3BA042 40,000 TDR 12.50 12.50 11.35 CK3BA048 40,500 TDR 13.00 13.00 11.60 CK5A/CK5BA042 40,000 TDR 12.50 12.50 11.35 CK5A/CK5BA048 40,500 TDR 13.00 13.00 11.55 CK5A/CK5BE042 40,000 TDR 12.50 12.50 11.40 CK5A/CK5BT042 40,000 TDR 12.50 12.50 11.35 CK5A/CK5BT048 40,500 TDR 13.00 13.00 11.55 CK5A/CK5BW048 40,500 TDR 13.00 13.00 11.65 COILS + 315(A,J)AV066135 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 11.55 CC5A/CD5AC048 39,500 TDR 12.50 12.50 11.45 CC5A/CD5AW042 39,500 TDR 12.50 12.50 11.65 CC5A/CD5AW048 40,000 TDR 13.00 13.00 11.65 CD5AA048 40,500 TDR 13.00 13.00 11.65 CE3AA042 40,000 TDR 12.50 12.50 11.60 CE3AA048 40,500 TDR 13.00 13.00 11.65 CK3BA042 40,000 TDR 12.50 12.50 11.55 CK3BA048 40,500 TDR 13.00 13.00 11.70 CK5A/CK5BA042 40,000 TDR 12.50 12.50 11.55 CK5A/CK5BA048 40,500 TDR 13.00 13.00 11.70 CK5A/CK5BT042 40,000 TDR 12.50 12.50 11.50 CK5A/CK5BT048 40,500 TDR 13.00 13.00 11.70 CK5A/CK5BW048 40,500 TDR 13.00 13.00 11.75 COILS + 315(A,J)AV066155 VARIABLE-SPEED FURNACE CE3AA042 40,000 TDR 12.50 12.50 11.65 CK3BA042 40,000 TDR 12.50 12.50 11.55 CK3BA048 40,500 TDR 13.00 13.00 11.75 CK5A/CK5BA042 40,000 TDR 12.50 12.50 11.55 CK5A/CK5BA048 40,500 TDR 13.00 13.00 11.70 CK5A/CK5BT042 40,000 TDR 12.50 12.50 11.55 CK5A/CK5BT048 40,500 TDR 13.00 13.00 11.70 CK5A/CK5BW048 40,500 TDR 13.00 13.00 11.80 COILS + 355MAV042060 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 11.30 CC5A/CD5AC048 39,500 TDR 12.50 12.50 11.15 CD5AA048 40,000 TDR 12.50 12.50 11.35 CE3AA042 40,000 TDR 12.50 12.50 11.35 CE3AA048 40,500 TDR 12.50 12.50 11.40 CK3BA042 40,000 TDR 12.50 12.50 11.30 CK3BA048 40,500 TDR 12.50 12.50 11.45 CK5A/CK5BA042 40,000 TDR 12.50 12.50 11.30 CK5A/CK5BA048 40,500 TDR 12.50 12.50 11.40 CK5A/CK5BE042 40,000 TDR 12.50 12.50 11.35 CK5A/CK5BT042 40,000 TDR 12.50 12.50 11.30 CK5A/CK5BT048 40,500 TDR 12.50 12.50 11.40 COILS + 355MAV042080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 11.10 CC5A/CD5AC048 39,500 TDR 12.50 12.50 11.00 CC5A/CD5AW042 39,500 TDR 12.50 12.50 11.20 CC5A/CD5AW048 40,000 TDR 12.50 12.50 11.25 CD5AA048 40,000 TDR 12.50 12.50 11.20 CE3AA042 40,000 TDR 12.50 12.50 11.15 CE3AA048 40,500 TDR 12.50 12.50 11.20 CK3BA042 40,000 TDR 12.50 12.50 11.10 CK3BA048 40,500 TDR 12.50 12.50 11.30 CK5A/CK5BA042 40,000 TDR 12.50 12.50 11.10 CK5A/CK5BA048 40,500 TDR 12.50 12.50 11.25 CK5A/CK5BE042 40,000 TDR 12.50 12.50 11.15 CK5A/CK5BT042 40,000 TDR 12.50 12.50 11.10 CK5A/CK5BT048 40,500 TDR 12.50 12.50 11.25 CK5A/CK5BW048 40,500 TDR 12.50 12.50 11.35 EER 14

COMBINATION RATINGS Continued UNIT SIZE-SERIES 042-E, F 042-G See notes on page 19. INDOOR MODEL TOT. CAP BTUH COILS + 355MAV060080 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 11.25 CC5A/CD5AC048 39,500 TDR 12.50 12.50 11.15 CC5A/CD5AW042 39,500 TDR 12.50 12.50 11.30 CC5A/CD5AW048 40,000 TDR 12.50 12.50 11.35 CD5AA048 40,000 TDR 12.50 12.50 11.30 CE3AA042 40,000 TDR 12.50 12.50 11.30 CE3AA048 40,500 TDR 12.50 12.50 11.35 CK3BA042 40,000 TDR 12.50 12.50 11.25 CK3BA048 40,500 TDR 12.50 12.50 11.40 CK5A/CK5BA042 40,000 TDR 12.50 12.50 11.25 CK5A/CK5BA048 40,500 TDR 12.50 12.50 11.35 CK5A/CK5BE042 40,000 TDR 12.50 12.50 11.30 CK5A/CK5BT042 40,000 TDR 12.50 12.50 11.25 CK5A/CK5BT048 40,500 TDR 12.50 12.50 11.35 CK5A/CK5BW048 40,500 TDR 12.50 12.50 11.45 COILS + 355MAV060100 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 11.30 CC5A/CD5AC048 39,500 TDR 12.50 12.50 11.20 CC5A/CD5AW042 39,500 TDR 12.50 12.50 11.40 CC5A/CD5AW048 40,000 TDR 13.00 13.00 11.45 CD5AA048 40,500 TDR 13.00 13.00 11.45 CE3AA042 40,000 TDR 12.50 12.50 11.35 CE3AA048 40,500 TDR 13.00 13.00 11.45 CK3BA042 40,000 TDR 12.50 12.50 11.30 CK3BA048 40,500 TDR 13.00 13.00 11.50 CK5A/CK5BA042 40,000 TDR 12.50 12.50 11.30 CK5A/CK5BA048 40,500 TDR 13.00 13.00 11.45 CK5A/CK5BE042 40,000 TDR 12.50 12.50 11.35 CK5A/CK5BT042 40,000 TDR 12.50 12.50 11.30 CK5A/CK5BT048 40,500 TDR 13.00 13.00 11.45 CK5A/CK5BW048 40,500 TDR 13.00 13.00 11.55 COILS + 355MAV060120 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 11.35 CC5A/CD5AC048 39,500 TDR 12.50 12.50 11.25 CC5A/CD5AW042 39,500 TDR 12.50 12.50 11.45 CC5A/CD5AW048 40,000 TDR 13.00 13.00 11.50 CD5AA048 40,500 TDR 13.00 13.00 11.45 CE3AA042 40,000 TDR 12.50 12.50 11.45 CE3AA048 40,500 TDR 13.00 13.00 11.50 CK3BA042 40,000 TDR 12.50 12.50 11.35 CK3BA048 40,500 TDR 13.00 13.00 11.55 CK5A/CK5BA042 40,000 TDR 12.50 12.50 11.35 CK5A/CK5BA048 40,500 TDR 13.00 13.00 11.50 CK5A/CK5BT042 40,000 TDR 12.50 12.50 11.35 CK5A/CK5BT048 40,500 TDR 13.00 13.00 11.50 CK5A/CK5BW048 40,500 TDR 13.00 13.00 11.60 CC5A/CD5AA042 40,000 NONE 12.00 12.00 11 CC5A/CD5AC048 40,000 NONE 12.00 12.00 10.85 CC5A/CD5AW042 40,000 NONE 12.00 12.00 10.85 CC5A/CD5AW048 40,500 NONE 12.00 12.00 11.00 CD5AA048 40,500 NONE 12.00 12.00 11.00 CE3AA042 40,000 NONE 12.00 12.00 11.05 CE3AA048 40,500 NONE 12.00 12.00 11.10 CF5AA048 40,500 NONE 12.00 12.00 11.05 CK3BA042 40,000 NONE 12.00 12.00 11.00 CK3BA048 40,500 NONE 12.00 12.00 11.05 CK5A/CK5BA042 40,000 NONE 12.00 12.00 11.00 CK5A/CK5BA048 40,500 NONE 12.00 12.00 11.05 CK5A/CK5BE042 40,000 NONE 12.00 12.00 11.05 CK5A/CK5BT042 40,000 NONE 12.00 12.00 11.00 CK5A/CK5BT048 40,500 NONE 12.00 12.00 11.05 CK5A/CK5BW048 40,500 NONE 12.00 12.00 11.05 F(A,B)4BN(F,B,C)042 40,000 TDR 12.00 12.00 10.85 F(A,B)4BN(F,B,C)048 40,500 TDR 12.00 12.00 11.05 FC4CN(F,B)042 40,000 TDR&TXV 12.00 10.85 FC4CN(F,B)048 40,500 TDR&TXV 12.00 11.05 FC4CNB054 42,000 TDR&TXV 12.50 11.70 FG3AAA048 40,500 NONE 12.00 12.00 10.95 FK4DNB006 42,000 TDR&TXV 14.00 12.65 FK4DNF003 41,000 TDR&TXV 13.00 11.90 FK4DNF005 41,500 TDR&TXV 13.50 12.40 COILS + 315(A,J)AV036070 VARIABLE-SPEED FURNACE CE3AA042 40,000 TDR 12.50 12.50 11.40 CE3AA048 40,500 TDR 12.50 12.50 11.45 CK5A/CK5BE042 40,000 TDR 12.50 12.50 11.40 COILS + 315(A,J)AV048090 VARIABLE-SPEED FURNACE CC5A/CD5AA042 40,000 TDR 12.50 12.50 11.65 CC5A/CD5AC048 39,500 TDR 12.50 12.50 11.50 CD5AA048 40,500 TDR 13.00 13.00 11.70 CE3AA042 40,000 TDR 12.50 12.50 11.70 CE3AA048 40,500 TDR 13.00 13.00 11.75 CK3BA042 40,000 TDR 12.50 12.50 11.65 CK3BA048 40,500 TDR 13.00 13.00 11.80 15 FACTORY- SUPPLIED ENHANCE- MENT STANDARD RATING SEER BRYANT GAS FURNACE OR TDR TXV EER